Insulation Testers

{"id":6152353972414,"title":"AEMC 1060 Digital Megohmmeter with Analog Bargraph and DataView Software, 1000V","handle":"aemc-1060-digital-megohmmeter-with-analog-bargraph-and-dataview-software-1000v","description":"\u003cp\u003e\u003cspan\u003eThe Digital\/Analog Megohmmeter Model 1060 is a fully automated 1000V insulation tester. It provides insulation measurements to 4000GΩ (4TΩ). Test results include DAR, PI, capacitance, voltage measurement and duration of test.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe True Megohmmeter\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e Model 1060 has an RS-232 interface and an extensive memory function, which permits storage results in files specific to a sample. A standard software package (DataView\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e) included with the Model 1060 enables the user to display test results and graphs. The Model 1060 can also be fully programmed and controlled by a PC. Automatic report generation of test results is quick and easy via direct connection to a printer or through a PC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue Megohmmeter\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eTest voltage combinations of 50V, 100V, 250V, 500V and 1000V\u003c\/li\u003e\n\u003cli\u003eInsulation measurement to 4000GΩ (4TΩ)\u003c\/li\u003e\n\u003cli\u003eDirect measurement of DAR and PI values\u003c\/li\u003e\n\u003cli\u003eDirect measurement of sample Capacitance\u003c\/li\u003e\n\u003cli\u003eDisplay of test voltage and run time\u003c\/li\u003e\n\u003cli\u003eProgrammable test run times and PI times\u003c\/li\u003e\n\u003cli\u003eSmooth and Alarm functions\u003c\/li\u003e\n\u003cli\u003eAutomatic test inhibition if live sample \u0026gt;25V\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge after use with voltage display\u003c\/li\u003e\n\u003cli\u003eLarge dual display with time, voltage and measurement\u003c\/li\u003e\n\u003cli\u003eBright blue electroluminescent backlight\u003c\/li\u003e\n\u003cli\u003eRemote operation with optional test probe\u003c\/li\u003e\n\u003cli\u003eRugged, dual wall, weatherproof field case with detachable lead\/accessory pouch\u003c\/li\u003e\n\u003cli\u003eEN 61010-1, 600V CAT III, EN 61557\u003c\/li\u003e\n\u003cli\u003eAC rechargeable NiMH batteries\u003c\/li\u003e\n\u003cli\u003e128kB memory to store measurements in specific files\u003c\/li\u003e\n\u003cli\u003eRemote operation through PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInsulation Tests\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V: 2kΩ to 200GΩ\u003cbr\u003e100 V: 4kΩ to 400GΩ\u003cbr\u003e250 V: 10kΩ to 1000GΩ (1TΩ)\u003cbr\u003e500 V: 20kΩ to 2000GΩ (2TΩ)\u003cbr\u003e1000 V: 40kΩ to 4000GΩ (4TΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2kΩ to 40GΩ: 5% of Reading ±3cts\u003cbr\u003e40GΩ to 4TΩ: ±15% of Reading ±10cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Test\/Safety Check\u003c\/td\u003e\n\u003ctd\u003eAC\/DC: 0 to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResistance Tests\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0.01 to 400kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage\u003c\/td\u003e\n\u003ctd\u003eMax DC: 12.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Current\u003c\/td\u003e\n\u003ctd\u003eDC: \u0026lt;6mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (\u0026gt;4kΩ)\u003c\/td\u003e\n\u003ctd\u003e±3% of Reading ±3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRechargeable NiMH Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCase: 9.45 x 7.28 x 4.33\" (240 x 185 x 110 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.5 lbs (120 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Megohmmeter\u003c\/li\u003e\n\u003cli\u003e2 x Test Leads (Red and Blue)\u003c\/li\u003e\n\u003cli\u003eBlack Shielded Lead\u003c\/li\u003e\n\u003cli\u003e3 x Alligator Clips (Black, Red and Blue)\u003c\/li\u003e\n\u003cli\u003eTest Probe (Black)\u003c\/li\u003e\n\u003cli\u003ePC RS-232 Cable\u003c\/li\u003e\n\u003cli\u003eDB9 F\/F 6ft Null Modem Cable\u003c\/li\u003e\n\u003cli\u003eRechargeable NiMH Battery\u003c\/li\u003e\n\u003cli\u003eDataview\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eSoftware\u003c\/li\u003e\n\u003cli\u003eUS 120V Power Cord\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_1050-60_-_2130-03_Megommeters.pdf?v=1609780051\" target=\"_blank\" title=\"AEMC 1060 Digital Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 1060 Digital Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-04T10:10:34-07:00","created_at":"2021-01-04T10:10:33-07:00","vendor":"AEMC Instruments","type":"Insulation Testers","tags":[],"price":362600,"price_min":362600,"price_max":362600,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37825426981054,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2130.03","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 1060 Digital Megohmmeter with Analog Bargraph and DataView Software, 1000V","public_title":null,"options":["Default Title"],"price":362600,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338150155","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC1060Pic1.png?v=1609780235"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC1060Pic1.png?v=1609780235","options":["Title"],"media":[{"alt":null,"id":15330004992190,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC1060Pic1.png?v=1609780235"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC1060Pic1.png?v=1609780235","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Digital\/Analog Megohmmeter Model 1060 is a fully automated 1000V insulation tester. It provides insulation measurements to 4000GΩ (4TΩ). Test results include DAR, PI, capacitance, voltage measurement and duration of test.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe True Megohmmeter\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e Model 1060 has an RS-232 interface and an extensive memory function, which permits storage results in files specific to a sample. A standard software package (DataView\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e) included with the Model 1060 enables the user to display test results and graphs. The Model 1060 can also be fully programmed and controlled by a PC. Automatic report generation of test results is quick and easy via direct connection to a printer or through a PC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue Megohmmeter\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eTest voltage combinations of 50V, 100V, 250V, 500V and 1000V\u003c\/li\u003e\n\u003cli\u003eInsulation measurement to 4000GΩ (4TΩ)\u003c\/li\u003e\n\u003cli\u003eDirect measurement of DAR and PI values\u003c\/li\u003e\n\u003cli\u003eDirect measurement of sample Capacitance\u003c\/li\u003e\n\u003cli\u003eDisplay of test voltage and run time\u003c\/li\u003e\n\u003cli\u003eProgrammable test run times and PI times\u003c\/li\u003e\n\u003cli\u003eSmooth and Alarm functions\u003c\/li\u003e\n\u003cli\u003eAutomatic test inhibition if live sample \u0026gt;25V\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge after use with voltage display\u003c\/li\u003e\n\u003cli\u003eLarge dual display with time, voltage and measurement\u003c\/li\u003e\n\u003cli\u003eBright blue electroluminescent backlight\u003c\/li\u003e\n\u003cli\u003eRemote operation with optional test probe\u003c\/li\u003e\n\u003cli\u003eRugged, dual wall, weatherproof field case with detachable lead\/accessory pouch\u003c\/li\u003e\n\u003cli\u003eEN 61010-1, 600V CAT III, EN 61557\u003c\/li\u003e\n\u003cli\u003eAC rechargeable NiMH batteries\u003c\/li\u003e\n\u003cli\u003e128kB memory to store measurements in specific files\u003c\/li\u003e\n\u003cli\u003eRemote operation through PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInsulation Tests\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V: 2kΩ to 200GΩ\u003cbr\u003e100 V: 4kΩ to 400GΩ\u003cbr\u003e250 V: 10kΩ to 1000GΩ (1TΩ)\u003cbr\u003e500 V: 20kΩ to 2000GΩ (2TΩ)\u003cbr\u003e1000 V: 40kΩ to 4000GΩ (4TΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2kΩ to 40GΩ: 5% of Reading ±3cts\u003cbr\u003e40GΩ to 4TΩ: ±15% of Reading ±10cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Test\/Safety Check\u003c\/td\u003e\n\u003ctd\u003eAC\/DC: 0 to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResistance Tests\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0.01 to 400kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage\u003c\/td\u003e\n\u003ctd\u003eMax DC: 12.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Current\u003c\/td\u003e\n\u003ctd\u003eDC: \u0026lt;6mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (\u0026gt;4kΩ)\u003c\/td\u003e\n\u003ctd\u003e±3% of Reading ±3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRechargeable NiMH Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCase: 9.45 x 7.28 x 4.33\" (240 x 185 x 110 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.5 lbs (120 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Megohmmeter\u003c\/li\u003e\n\u003cli\u003e2 x Test Leads (Red and Blue)\u003c\/li\u003e\n\u003cli\u003eBlack Shielded Lead\u003c\/li\u003e\n\u003cli\u003e3 x Alligator Clips (Black, Red and Blue)\u003c\/li\u003e\n\u003cli\u003eTest Probe (Black)\u003c\/li\u003e\n\u003cli\u003ePC RS-232 Cable\u003c\/li\u003e\n\u003cli\u003eDB9 F\/F 6ft Null Modem Cable\u003c\/li\u003e\n\u003cli\u003eRechargeable NiMH Battery\u003c\/li\u003e\n\u003cli\u003eDataview\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eSoftware\u003c\/li\u003e\n\u003cli\u003eUS 120V Power Cord\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_1050-60_-_2130-03_Megommeters.pdf?v=1609780051\" target=\"_blank\" title=\"AEMC 1060 Digital Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 1060 Digital Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 1060 Digital Megohmmeter with Analog Bargraph and DataView Software, 1000V

AEMC 1060 Digital Megohmmeter with Analog Bargraph and DataView Software, 1000V

$3,626.00 CAD

The Digital/Analog Megohmmeter Model 1060 is a fully automated 1000V insulation tester. It provides insulation measurements to 4000GΩ (4TΩ). Test results include DAR, PI, capacitance, voltage measurement and duration of test.The True Megohmmeter® Model 1060 has an RS-232 interface and an extensive memory function, which permits storage results i...


More Info
{"id":6152750530750,"title":"AEMC 5050 Digital Megohmmeter with Analog Bargraph, 5000V","handle":"aemc-5050-digital-megohmmeter-with-analog-bargraph-5000v","description":"\u003cp\u003e\u003cspan\u003eThe Digital\/Analog Megohmmeter Model 5050 is the latest design in 5000V insulation testers. Features include automatic calculation and presentation of the Dielectric Absorption Ratio (DAR), Polarization Index (PI) and Dielectric Discharge (DD). The True Megohmmeter\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e Model 5050 displays the test voltage, insulation resistance and the leakage current during the test. Capacitance of the sample and discharge voltage present at the test leads are displayed at the conclusion of the test. This meter is designed with the highest level of built-in safety features. The Model 5050 can be operated from an internal rechargeable battery or from AC line power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic voltage detection in all functions, before or during the measurement, which inhibits or stops the measurement\u003c\/li\u003e\n\u003cli\u003eAutomatic detection of external AC or DC voltages on the terminals\u003c\/li\u003e\n\u003cli\u003eThreshold programming in each function, triggering audible alarms\u003c\/li\u003e\n\u003cli\u003eTimed control of measurement duration\u003c\/li\u003e\n\u003cli\u003eFuse protection, with defective fuse detection and indication\u003c\/li\u003e\n\u003cli\u003eDigital filtering of insulation measurements\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge of residual high voltage on the tested device\u003c\/li\u003e\n\u003cli\u003eAutomatic shut-off to save the batteries\u003c\/li\u003e\n\u003cli\u003eBattery level indicator\u003c\/li\u003e\n\u003cli\u003eLarge easy-to-read back-lit LCD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInsulation Tests\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V: 30kΩ to 2000GΩ (2TΩ)\u003cbr\u003e1000 V: 100kΩ to 4000GΩ (4TΩ)\u003cbr\u003e2500 V: 100kΩ to 10,000GΩ (10TΩ)\u003cbr\u003e5000 V: 300kΩ to 10,0000GΩ (10TΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1kΩ to 40GΩ: ±5% of Reading ±3cts\u003cbr\u003e40GΩ to 10TΩ: ±15% of Reading ±10cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Test\/Safety Check\u003c\/td\u003e\n\u003ctd\u003eAC\/DC: 0 to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eDuring recharging of batteries: 14 to 104°F (-10 to 40°C)\u003cbr\u003eDuring measurement: 14 to 131°F (-10 to 55°C)\u003cbr\u003eRH: 10 to 80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-40 to 158°F (-40 to 70°C)\u003cbr\u003eRH: 10 to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e9.6V Rechargeable NiMH Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCase: 10.63 x 9.84 x 7.09\" (270 x 250 x 180 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 9.5 lbs (4.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span10\"\u003e\n\u003cdiv class=\"mhide ipad-view-setting\"\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"row-fluid ProductTabs\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv id=\"tab2\" class=\"product-tabs tab-pane active\"\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Megohmmeter\u003c\/li\u003e\n\u003cli\u003eTest Leads with Integral 5kV Rated Hippo Clips (Red, Blue and Black)\u003c\/li\u003e\n\u003cli\u003eJumper Lead for use with Guard Terminal\u003c\/li\u003e\n\u003cli\u003eRechargeable Battery\u003c\/li\u003e\n\u003cli\u003eUS 120V Power Cord\u003c\/li\u003e\n\u003cli\u003eExtra Large Classic Tool Bag\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row-fluid\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"span2 mhide ipad-view-setting\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_5050-5060_-_2130.20_-_5KV_Insulation_Tester_Spec_Sheet.pdf?v=1609794113\" target=\"_blank\" title=\"AEMC 5050 Digital Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 5050 Digital Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-04T14:51:13-07:00","created_at":"2021-01-04T14:14:22-07:00","vendor":"AEMC Instruments","type":"Insulation Testers","tags":[],"price":460600,"price_min":460600,"price_max":460600,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37827014656190,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2130.20","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 5050 Digital Megohmmeter with Analog Bargraph, 5000V","public_title":null,"options":["Default Title"],"price":460600,"weight":10433,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338150162","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC5050Pic1.png?v=1609797007"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC5050Pic1.png?v=1609797007","options":["Title"],"media":[{"alt":null,"id":15332068425918,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC5050Pic1.png?v=1609797007"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC5050Pic1.png?v=1609797007","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Digital\/Analog Megohmmeter Model 5050 is the latest design in 5000V insulation testers. Features include automatic calculation and presentation of the Dielectric Absorption Ratio (DAR), Polarization Index (PI) and Dielectric Discharge (DD). The True Megohmmeter\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e Model 5050 displays the test voltage, insulation resistance and the leakage current during the test. Capacitance of the sample and discharge voltage present at the test leads are displayed at the conclusion of the test. This meter is designed with the highest level of built-in safety features. The Model 5050 can be operated from an internal rechargeable battery or from AC line power.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic voltage detection in all functions, before or during the measurement, which inhibits or stops the measurement\u003c\/li\u003e\n\u003cli\u003eAutomatic detection of external AC or DC voltages on the terminals\u003c\/li\u003e\n\u003cli\u003eThreshold programming in each function, triggering audible alarms\u003c\/li\u003e\n\u003cli\u003eTimed control of measurement duration\u003c\/li\u003e\n\u003cli\u003eFuse protection, with defective fuse detection and indication\u003c\/li\u003e\n\u003cli\u003eDigital filtering of insulation measurements\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge of residual high voltage on the tested device\u003c\/li\u003e\n\u003cli\u003eAutomatic shut-off to save the batteries\u003c\/li\u003e\n\u003cli\u003eBattery level indicator\u003c\/li\u003e\n\u003cli\u003eLarge easy-to-read back-lit LCD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInsulation Tests\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V: 30kΩ to 2000GΩ (2TΩ)\u003cbr\u003e1000 V: 100kΩ to 4000GΩ (4TΩ)\u003cbr\u003e2500 V: 100kΩ to 10,000GΩ (10TΩ)\u003cbr\u003e5000 V: 300kΩ to 10,0000GΩ (10TΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1kΩ to 40GΩ: ±5% of Reading ±3cts\u003cbr\u003e40GΩ to 10TΩ: ±15% of Reading ±10cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Test\/Safety Check\u003c\/td\u003e\n\u003ctd\u003eAC\/DC: 0 to 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003eDuring recharging of batteries: 14 to 104°F (-10 to 40°C)\u003cbr\u003eDuring measurement: 14 to 131°F (-10 to 55°C)\u003cbr\u003eRH: 10 to 80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-40 to 158°F (-40 to 70°C)\u003cbr\u003eRH: 10 to 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e9.6V Rechargeable NiMH Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCase: 10.63 x 9.84 x 7.09\" (270 x 250 x 180 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 9.5 lbs (4.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span10\"\u003e\n\u003cdiv class=\"mhide ipad-view-setting\"\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"row-fluid ProductTabs\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv id=\"tab2\" class=\"product-tabs tab-pane active\"\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Megohmmeter\u003c\/li\u003e\n\u003cli\u003eTest Leads with Integral 5kV Rated Hippo Clips (Red, Blue and Black)\u003c\/li\u003e\n\u003cli\u003eJumper Lead for use with Guard Terminal\u003c\/li\u003e\n\u003cli\u003eRechargeable Battery\u003c\/li\u003e\n\u003cli\u003eUS 120V Power Cord\u003c\/li\u003e\n\u003cli\u003eExtra Large Classic Tool Bag\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row-fluid\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"span2 mhide ipad-view-setting\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_5050-5060_-_2130.20_-_5KV_Insulation_Tester_Spec_Sheet.pdf?v=1609794113\" target=\"_blank\" title=\"AEMC 5050 Digital Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 5050 Digital Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 5050 Digital Megohmmeter with Analog Bargraph, 5000V

AEMC 5050 Digital Megohmmeter with Analog Bargraph, 5000V

$4,606.00 CAD

The Digital/Analog Megohmmeter Model 5050 is the latest design in 5000V insulation testers. Features include automatic calculation and presentation of the Dielectric Absorption Ratio (DAR), Polarization Index (PI) and Dielectric Discharge (DD). The True Megohmmeter® Model 5050 displays the test voltage, insulation resistance and the leakage curr...


More Info
{"id":6152811020478,"title":"AEMC 5070 Graphical Megohmmeter with Analog Bargraph and DataView Software, 5000V","handle":"aemc-5070-graphical-megohmmeter-with-analog-bargraph-and-dataview-software-5000v","description":"\u003cp\u003e\u003cspan\u003eThe Megohmmeter Model 5070 is a fully automated 5000V graphical insulation tester. This True Megohmmeter\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e features selectable and programmable test voltage (40 to 5100V) and programmable temperature correction of resistance readings. The Model 5070 is the only megohmmeter to offer both a graphical plot of the test right on the instrument, as well as a digital presentation of the test results. It has a large graphic display with five line alphanumeric display and graph. It also offers the ability to program up to three step voltage profiles, each containing up to five steps. The Model 5070 has an RS-232 port which provides the ability to configure the unit and run the test from a PC. Test results can be generated directly to a printer using the DataView\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e graphing and analysis software.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue Megohmmeter\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ewith selectable test voltage from 40 to 5100V, and fixed test voltages of 500V, 1000V, 2500V and 5000V\u003c\/li\u003e\n\u003cli\u003eInsulation measurements from 30kΩ to 10TΩ\u003c\/li\u003e\n\u003cli\u003eAutomatic calculation of DAR, PI and DD ratios\u003c\/li\u003e\n\u003cli\u003eDirect measurement and display of Capacitance and Leakage Current\u003c\/li\u003e\n\u003cli\u003eDisplay resistance, test voltage and run time\u003c\/li\u003e\n\u003cli\u003eProgrammable test run times and PI ratio times\u003c\/li\u003e\n\u003cli\u003eSmooth and Alarm functions\u003c\/li\u003e\n\u003cli\u003eAutomatic test inhibition (if live sample \u0026gt;25V)\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge and display of discharge voltage\u003c\/li\u003e\n\u003cli\u003eGraphic and digital display of test voltage, resistance and more\u003c\/li\u003e\n\u003cli\u003eBright blue electroluminescent backlight\u003c\/li\u003e\n\u003cli\u003eProgrammable temperature compensation\u003c\/li\u003e\n\u003cli\u003eProgrammable test voltage lock-out\u003c\/li\u003e\n\u003cli\u003eProgrammable alarm setting\u003c\/li\u003e\n\u003cli\u003eAuto power-down when not in use\u003c\/li\u003e\n\u003cli\u003eAC or DC powered with rechargeable NiMH battery pack - run while charging\u003c\/li\u003e\n\u003cli\u003eRugged, weatherproof field case\u003c\/li\u003e\n\u003cli\u003eDesigned and built to IEC safety standards\u003c\/li\u003e\n\u003cli\u003eEN 61010-1, 1000V CAT III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInsulation Tests\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e500 V: 30kΩ to 2000GΩ (2TΩ)\u003cbr\u003e1000 V: 100kΩ to 4000GΩ (4TΩ)\u003cbr\u003e2500 V: 100kΩ to 10,000GΩ (10TΩ)\u003cbr\u003e5000 V: 300kΩ to 10,000GΩ (10TΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1kΩ to 40GΩ: ±5% of Reading ±3cts\u003cbr\u003e40GΩ to 10TΩ: ±15% of Reading ±10cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Test\/Safety Check\u003c\/td\u003e\n\u003ctd\u003eAC\/DC: 0 to 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Warning Indicator\u003c\/td\u003e\n\u003ctd\u003eYes \u0026gt;25 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage of Readings over Time R(t)\u003c\/td\u003e\n\u003ctd\u003e128kB Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage of Test Results\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;1500 Test Results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e9.6V NiMH Battery Pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCase: 10.63 x 9.84 x 7.09\" (270 x 250 x 180 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 9.5 lbs (4.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGraphical Megohmmeter\u003c\/li\u003e\n\u003cli\u003eSet of 3 10' (5kV) Leads (Red, Black and Blue) with Integral Hippo Clips (5000 V)\u003c\/li\u003e\n\u003cli\u003eGuard Terminal Jumper Lead\u003c\/li\u003e\n\u003cli\u003eRS-232 DB9 F\/F 6' Null Modem Cable\u003c\/li\u003e\n\u003cli\u003eRS-232 to USB Adapter\u003c\/li\u003e\n\u003cli\u003eUS 115V Power Cord\u003c\/li\u003e\n\u003cli\u003eRechargeable 9.6V NiMH Battery Pack\u003c\/li\u003e\n\u003cli\u003eUSB Stick with DataView\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eSoftware\u003c\/li\u003e\n\u003cli\u003eExtra Large Tool Bag\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC-2130.30-Model-5070.pdf?v=1609797215\" target=\"_blank\" title=\"AEMC 5070 Graphical Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 5070 Graphical Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-04T14:59:24-07:00","created_at":"2021-01-04T14:59:24-07:00","vendor":"AEMC Instruments","type":"Insulation Testers","tags":[],"price":640500,"price_min":640500,"price_max":640500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37827255500990,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2130.30","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 5070 Graphical Megohmmeter with Analog Bargraph and DataView Software, 5000V","public_title":null,"options":["Default Title"],"price":640500,"weight":10433,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338150186","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC5070Pic1.png?v=1609797566"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC5070Pic1.png?v=1609797566","options":["Title"],"media":[{"alt":null,"id":15332114825406,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC5070Pic1.png?v=1609797566"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC5070Pic1.png?v=1609797566","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Megohmmeter Model 5070 is a fully automated 5000V graphical insulation tester. This True Megohmmeter\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e features selectable and programmable test voltage (40 to 5100V) and programmable temperature correction of resistance readings. The Model 5070 is the only megohmmeter to offer both a graphical plot of the test right on the instrument, as well as a digital presentation of the test results. It has a large graphic display with five line alphanumeric display and graph. It also offers the ability to program up to three step voltage profiles, each containing up to five steps. The Model 5070 has an RS-232 port which provides the ability to configure the unit and run the test from a PC. Test results can be generated directly to a printer using the DataView\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e graphing and analysis software.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue Megohmmeter\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ewith selectable test voltage from 40 to 5100V, and fixed test voltages of 500V, 1000V, 2500V and 5000V\u003c\/li\u003e\n\u003cli\u003eInsulation measurements from 30kΩ to 10TΩ\u003c\/li\u003e\n\u003cli\u003eAutomatic calculation of DAR, PI and DD ratios\u003c\/li\u003e\n\u003cli\u003eDirect measurement and display of Capacitance and Leakage Current\u003c\/li\u003e\n\u003cli\u003eDisplay resistance, test voltage and run time\u003c\/li\u003e\n\u003cli\u003eProgrammable test run times and PI ratio times\u003c\/li\u003e\n\u003cli\u003eSmooth and Alarm functions\u003c\/li\u003e\n\u003cli\u003eAutomatic test inhibition (if live sample \u0026gt;25V)\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge and display of discharge voltage\u003c\/li\u003e\n\u003cli\u003eGraphic and digital display of test voltage, resistance and more\u003c\/li\u003e\n\u003cli\u003eBright blue electroluminescent backlight\u003c\/li\u003e\n\u003cli\u003eProgrammable temperature compensation\u003c\/li\u003e\n\u003cli\u003eProgrammable test voltage lock-out\u003c\/li\u003e\n\u003cli\u003eProgrammable alarm setting\u003c\/li\u003e\n\u003cli\u003eAuto power-down when not in use\u003c\/li\u003e\n\u003cli\u003eAC or DC powered with rechargeable NiMH battery pack - run while charging\u003c\/li\u003e\n\u003cli\u003eRugged, weatherproof field case\u003c\/li\u003e\n\u003cli\u003eDesigned and built to IEC safety standards\u003c\/li\u003e\n\u003cli\u003eEN 61010-1, 1000V CAT III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInsulation Tests\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e500 V: 30kΩ to 2000GΩ (2TΩ)\u003cbr\u003e1000 V: 100kΩ to 4000GΩ (4TΩ)\u003cbr\u003e2500 V: 100kΩ to 10,000GΩ (10TΩ)\u003cbr\u003e5000 V: 300kΩ to 10,000GΩ (10TΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1kΩ to 40GΩ: ±5% of Reading ±3cts\u003cbr\u003e40GΩ to 10TΩ: ±15% of Reading ±10cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Test\/Safety Check\u003c\/td\u003e\n\u003ctd\u003eAC\/DC: 0 to 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Warning Indicator\u003c\/td\u003e\n\u003ctd\u003eYes \u0026gt;25 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage of Readings over Time R(t)\u003c\/td\u003e\n\u003ctd\u003e128kB Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage of Test Results\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;1500 Test Results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e9.6V NiMH Battery Pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCase: 10.63 x 9.84 x 7.09\" (270 x 250 x 180 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 9.5 lbs (4.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGraphical Megohmmeter\u003c\/li\u003e\n\u003cli\u003eSet of 3 10' (5kV) Leads (Red, Black and Blue) with Integral Hippo Clips (5000 V)\u003c\/li\u003e\n\u003cli\u003eGuard Terminal Jumper Lead\u003c\/li\u003e\n\u003cli\u003eRS-232 DB9 F\/F 6' Null Modem Cable\u003c\/li\u003e\n\u003cli\u003eRS-232 to USB Adapter\u003c\/li\u003e\n\u003cli\u003eUS 115V Power Cord\u003c\/li\u003e\n\u003cli\u003eRechargeable 9.6V NiMH Battery Pack\u003c\/li\u003e\n\u003cli\u003eUSB Stick with DataView\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eSoftware\u003c\/li\u003e\n\u003cli\u003eExtra Large Tool Bag\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC-2130.30-Model-5070.pdf?v=1609797215\" target=\"_blank\" title=\"AEMC 5070 Graphical Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 5070 Graphical Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 5070 Graphical Megohmmeter with Analog Bargraph and DataView Software, 5000V

AEMC 5070 Graphical Megohmmeter with Analog Bargraph and DataView Software, 5000V

$6,405.00 CAD

The Megohmmeter Model 5070 is a fully automated 5000V graphical insulation tester. This True Megohmmeter® features selectable and programmable test voltage (40 to 5100V) and programmable temperature correction of resistance readings. The Model 5070 is the only megohmmeter to offer both a graphical plot of the test right on the instrument, as wel...


More Info
AEMC 6503 Hand-Crank Megohmmeter, 1000V

Insulation Testers

$938.00 CAD
{"id":6139428995262,"title":"AEMC 6503 Hand-Crank Megohmmeter, 1000V","handle":"aemc-6503-hand-crank-megohmmeter-1000v","description":"\u003cp\u003e\u003cspan\u003eThe Megohmmeter Model 6503 is a compact, self-contained, hand-cranked True Megohmmeter\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e. This practical and dependable instrument is designed for a broad range of plant and field service applications, such as acceptance testing and preventive maintenance of wiring, cables, switchgear and motors. The easy hand-cranked operation provides a steady, DC voltage output across the entire range for consistently reliable readings. The Model 6503 has three test voltages for insulation resistance testing: 250V, 500V and 1000V. Test voltages are generated in full across the entire measurement range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue Megohmmeter\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eTest voltages of 250V, 500V and 1000V (model dependent)\u003c\/li\u003e\n\u003cli\u003eInsulation measurements to 200 and 5000MΩ\u003c\/li\u003e\n\u003cli\u003eLED indicates constant voltage output and proper cranked speed controlled by voltage regulator\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge when measurement is finished\u003c\/li\u003e\n\u003cli\u003eAuto-Ranging – dual scale operation for better sensitivity and easier readings\u003c\/li\u003e\n\u003cli\u003eCompact self-contained package; folded crank\u003c\/li\u003e\n\u003cli\u003eVoltage displayed prior to, during and at the end of test\u003c\/li\u003e\n\u003cli\u003eLarge direct reading scale\u003c\/li\u003e\n\u003cli\u003eEN 61010-1, 600V CAT II, 300V CAT III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInsulation Tests\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Range\u003c\/td\u003e\n\u003ctd\u003e250V: 1 to 11MΩ; 11 to 500MΩ\u003cbr\u003e500V: 0.5 to 5.5MΩ; 5.5 to 200MΩ\u003cbr\u003e1000V: 10 to 110MΩ; 110 to 5000MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current\u003c\/td\u003e\n\u003ctd\u003eMax: 5mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Measurement\/Safety Check\u003c\/td\u003e\n\u003ctd\u003e0 to 600V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (MΩ)\u003c\/td\u003e\n\u003ctd\u003e2.5% of Full Scale Length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Discharge\u003c\/td\u003e\n\u003ctd\u003e8s\/µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge Time\u003c\/td\u003e\n\u003ctd\u003e250V: 0.2s\/µF\u003cbr\u003e500V: 0.5s\/µF\u003cbr\u003e1000V: 0.5s\/µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eReference: 68 to 79°F (20 to 26°C), 30 to 50% RH\u003cbr\u003eOperating Range: 14 to 113°F (-10 to 45°C), 0 to 75% RH\u003cbr\u003eStorage Range: -4 to 176°F (-20 to 80°C), 0 to 90% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eWith Lid: 4.7 x 4.4 x 5.3\" (120 x 111 x 135 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 lbs (1.1 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHand-Crank Megohmmeter\u003c\/li\u003e\n\u003cli\u003e3 x Color-Coded Leads\u003c\/li\u003e\n\u003cli\u003e3 x Insulated Alligator Clips\u003c\/li\u003e\n\u003cli\u003eTest Probe\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_6503_-_2126-52_Megohmmeter.pdf?v=1608827714\" target=\"_blank\" title=\"AEMC 6503 Hand-Crank Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 6503 Hand-Crank Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2020-12-24T09:47:52-07:00","created_at":"2020-12-24T09:47:51-07:00","vendor":"AEMC Instruments","type":"Insulation Testers","tags":[],"price":93800,"price_min":93800,"price_max":93800,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37772863701182,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2126.52","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 6503 Hand-Crank Megohmmeter, 1000V","public_title":null,"options":["Default Title"],"price":93800,"weight":1134,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338150216","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6503Pic1.png?v=1608828475"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6503Pic1.png?v=1608828475","options":["Title"],"media":[{"alt":null,"id":15264571850942,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6503Pic1.png?v=1608828475"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6503Pic1.png?v=1608828475","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Megohmmeter Model 6503 is a compact, self-contained, hand-cranked True Megohmmeter\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e. This practical and dependable instrument is designed for a broad range of plant and field service applications, such as acceptance testing and preventive maintenance of wiring, cables, switchgear and motors. The easy hand-cranked operation provides a steady, DC voltage output across the entire range for consistently reliable readings. The Model 6503 has three test voltages for insulation resistance testing: 250V, 500V and 1000V. Test voltages are generated in full across the entire measurement range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue Megohmmeter\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eTest voltages of 250V, 500V and 1000V (model dependent)\u003c\/li\u003e\n\u003cli\u003eInsulation measurements to 200 and 5000MΩ\u003c\/li\u003e\n\u003cli\u003eLED indicates constant voltage output and proper cranked speed controlled by voltage regulator\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge when measurement is finished\u003c\/li\u003e\n\u003cli\u003eAuto-Ranging – dual scale operation for better sensitivity and easier readings\u003c\/li\u003e\n\u003cli\u003eCompact self-contained package; folded crank\u003c\/li\u003e\n\u003cli\u003eVoltage displayed prior to, during and at the end of test\u003c\/li\u003e\n\u003cli\u003eLarge direct reading scale\u003c\/li\u003e\n\u003cli\u003eEN 61010-1, 600V CAT II, 300V CAT III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInsulation Tests\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Range\u003c\/td\u003e\n\u003ctd\u003e250V: 1 to 11MΩ; 11 to 500MΩ\u003cbr\u003e500V: 0.5 to 5.5MΩ; 5.5 to 200MΩ\u003cbr\u003e1000V: 10 to 110MΩ; 110 to 5000MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current\u003c\/td\u003e\n\u003ctd\u003eMax: 5mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Measurement\/Safety Check\u003c\/td\u003e\n\u003ctd\u003e0 to 600V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (MΩ)\u003c\/td\u003e\n\u003ctd\u003e2.5% of Full Scale Length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Discharge\u003c\/td\u003e\n\u003ctd\u003e8s\/µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge Time\u003c\/td\u003e\n\u003ctd\u003e250V: 0.2s\/µF\u003cbr\u003e500V: 0.5s\/µF\u003cbr\u003e1000V: 0.5s\/µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eReference: 68 to 79°F (20 to 26°C), 30 to 50% RH\u003cbr\u003eOperating Range: 14 to 113°F (-10 to 45°C), 0 to 75% RH\u003cbr\u003eStorage Range: -4 to 176°F (-20 to 80°C), 0 to 90% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eWith Lid: 4.7 x 4.4 x 5.3\" (120 x 111 x 135 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 lbs (1.1 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHand-Crank Megohmmeter\u003c\/li\u003e\n\u003cli\u003e3 x Color-Coded Leads\u003c\/li\u003e\n\u003cli\u003e3 x Insulated Alligator Clips\u003c\/li\u003e\n\u003cli\u003eTest Probe\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_6503_-_2126-52_Megohmmeter.pdf?v=1608827714\" target=\"_blank\" title=\"AEMC 6503 Hand-Crank Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 6503 Hand-Crank Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 6503 Hand-Crank Megohmmeter, 1000V

AEMC 6503 Hand-Crank Megohmmeter, 1000V

$938.00 CAD

The Megohmmeter Model 6503 is a compact, self-contained, hand-cranked True Megohmmeter®. This practical and dependable instrument is designed for a broad range of plant and field service applications, such as acceptance testing and preventive maintenance of wiring, cables, switchgear and motors. The easy hand-cranked operation provides a steady,...


More Info
{"id":6152378843326,"title":"AEMC 6505 Digital Megohmmeter w\/ Analog Bargraph and Auto DAR\/PI, 5000V","handle":"aemc-6505-digital-megohmmeter-w-analog-bargraph-and-auto-dar-pi-5000v","description":"\u003cp\u003eThe Megohmmeter Model 6505 is a True Megohmmeter\u003csup\u003e® \u003c\/sup\u003eportable instrument housed in a rugged field case that operates on either battery or line power. It performs voltage, insulation, and capacitance measurements. This instrument contributes to the safety of electrical installations and equipment.\u003c\/p\u003e\n\u003cp\u003eFeatures include automatic calculation and presentation of the Dielectric Absorption Ratio (DAR) and Polarization Index (PI). The Model 6505 displays the test voltage, insulation resistance and the leakage current during the test. Capacitance of the sample and discharge voltage present at the test leads is displayed at the conclusion of the test.\u003c\/p\u003e\n\u003cp\u003eThe Model 6505 is designed with a high level of built-in safety features. This meter incorporates test inhibit capabilities which will not allow test voltages to be generated if a live sample is detected. The test terminals are recessed to ensure operating safety.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest voltage combination of 500V, 1000V, 2500V and 5000V\u003c\/li\u003e\n\u003cli\u003eInsulation measurements from 30kΩ to 10TΩ\u003c\/li\u003e\n\u003cli\u003eAdjustable and programmable test voltage (40 to 5100V)\u003c\/li\u003e\n\u003cli\u003eAutomatic calculation of DAR and PI values\u003c\/li\u003e\n\u003cli\u003eDirect measurement and display of Capacitance and Leakage Current\u003c\/li\u003e\n\u003cli\u003eDisplay of resistance, test voltage and run time\u003c\/li\u003e\n\u003cli\u003eProgrammable test run times and PI ratio times\u003c\/li\u003e\n\u003cli\u003eAutomatic test inhibition, if live sample (\u0026gt;25)\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge and display of discharge voltage\u003c\/li\u003e\n\u003cli\u003eLarge dual-display with time, voltage and measurements shown\u003c\/li\u003e\n\u003cli\u003eRugged dual wall weatherproof field case\u003c\/li\u003e\n\u003cli\u003eDesigned and built to IEC safety standards\u003c\/li\u003e\n\u003cli\u003eEN 61010-1, 1000V CAT III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage\/Range\u003c\/td\u003e\n\u003ctd\u003e500V: 30kΩ to 2000GΩ (2TΩ)\u003cbr\u003e1000V: 100kΩ to 4000GΩ (4TΩ)\u003cbr\u003e2500V: 100kΩ to 10,000GΩ (10TΩ)\u003cbr\u003e5000V: 300kΩ to 10,000GΩ (10TΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Programmable Test\u003c\/td\u003e\n\u003ctd\u003e40 to 1000V: 10V increments\u003cbr\u003e1000 to 5100V: 100V increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1.6mA ± 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e10kΩ to 40GΩ: ±5% of Reading ± 3cts\u003cbr\u003e40GΩ to 10TΩ: ±15% of Reading ± 10cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDAR (1 min\/30 sec)\u003c\/td\u003e\n\u003ctd\u003e0.02 to 50.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePI (10 min\/1 min \u0026amp; user programmable)\u003c\/td\u003e\n\u003ctd\u003e0.02 to 50.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Measurement\u003c\/td\u003e\n\u003ctd\u003e0.005 to 49.99µF\u003cbr\u003eMax resolution 1nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current Measurement\u003c\/td\u003e\n\u003ctd\u003e0.00nA to 3mA\u003cbr\u003eMax resolution 1pA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Run Time R(t)\u003c\/td\u003e\n\u003ctd\u003e1 to 60 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge After Test\u003c\/td\u003e\n\u003ctd\u003eYes, automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge Voltage Display\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Test\/Safety Check\u003c\/td\u003e\n\u003ctd\u003e0 to 1000V AC\/DC (16 to 420Hz)\u003cbr\u003e1V Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Megohmmeter\u003c\/li\u003e\n\u003cli\u003eSet of 6' Leads, 5000V (Red, Blue, and Black)\u003c\/li\u003e\n\u003cli\u003eSet of Alligator Clips, 600V CAT IV, (Red, Blue, and Black)\u003c\/li\u003e\n\u003cli\u003eBlue Guard Terminal Jumper Lead\u003c\/li\u003e\n\u003cli\u003eFuse, 0.1A 380V\u003c\/li\u003e\n\u003cli\u003eRechargeable Battery Pack\u003c\/li\u003e\n\u003cli\u003eUS 115V Power Cord\u003c\/li\u003e\n\u003cli\u003eExtra Large Tool Bag\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_6505_-_2130.18_-_5KV_Insulation_Tester_Spec.pdf?v=1609780939\" target=\"_blank\" title=\"AEMC 6505 Digital Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 6505 Digital Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-04T10:27:56-07:00","created_at":"2021-01-04T10:27:55-07:00","vendor":"AEMC Instruments","type":"Insulation Testers","tags":[],"price":399000,"price_min":399000,"price_max":399000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37825498153150,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2130.18","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 6505 Digital Megohmmeter w\/ Analog Bargraph and Auto DAR\/PI, 5000V","public_title":null,"options":["Default Title"],"price":399000,"weight":10433,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338150223","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6505Pic1.png?v=1609781279"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6505Pic1.png?v=1609781279","options":["Title"],"media":[{"alt":null,"id":15330113487038,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6505Pic1.png?v=1609781279"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6505Pic1.png?v=1609781279","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe Megohmmeter Model 6505 is a True Megohmmeter\u003csup\u003e® \u003c\/sup\u003eportable instrument housed in a rugged field case that operates on either battery or line power. It performs voltage, insulation, and capacitance measurements. This instrument contributes to the safety of electrical installations and equipment.\u003c\/p\u003e\n\u003cp\u003eFeatures include automatic calculation and presentation of the Dielectric Absorption Ratio (DAR) and Polarization Index (PI). The Model 6505 displays the test voltage, insulation resistance and the leakage current during the test. Capacitance of the sample and discharge voltage present at the test leads is displayed at the conclusion of the test.\u003c\/p\u003e\n\u003cp\u003eThe Model 6505 is designed with a high level of built-in safety features. This meter incorporates test inhibit capabilities which will not allow test voltages to be generated if a live sample is detected. The test terminals are recessed to ensure operating safety.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest voltage combination of 500V, 1000V, 2500V and 5000V\u003c\/li\u003e\n\u003cli\u003eInsulation measurements from 30kΩ to 10TΩ\u003c\/li\u003e\n\u003cli\u003eAdjustable and programmable test voltage (40 to 5100V)\u003c\/li\u003e\n\u003cli\u003eAutomatic calculation of DAR and PI values\u003c\/li\u003e\n\u003cli\u003eDirect measurement and display of Capacitance and Leakage Current\u003c\/li\u003e\n\u003cli\u003eDisplay of resistance, test voltage and run time\u003c\/li\u003e\n\u003cli\u003eProgrammable test run times and PI ratio times\u003c\/li\u003e\n\u003cli\u003eAutomatic test inhibition, if live sample (\u0026gt;25)\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge and display of discharge voltage\u003c\/li\u003e\n\u003cli\u003eLarge dual-display with time, voltage and measurements shown\u003c\/li\u003e\n\u003cli\u003eRugged dual wall weatherproof field case\u003c\/li\u003e\n\u003cli\u003eDesigned and built to IEC safety standards\u003c\/li\u003e\n\u003cli\u003eEN 61010-1, 1000V CAT III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage\/Range\u003c\/td\u003e\n\u003ctd\u003e500V: 30kΩ to 2000GΩ (2TΩ)\u003cbr\u003e1000V: 100kΩ to 4000GΩ (4TΩ)\u003cbr\u003e2500V: 100kΩ to 10,000GΩ (10TΩ)\u003cbr\u003e5000V: 300kΩ to 10,000GΩ (10TΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Programmable Test\u003c\/td\u003e\n\u003ctd\u003e40 to 1000V: 10V increments\u003cbr\u003e1000 to 5100V: 100V increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1.6mA ± 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e10kΩ to 40GΩ: ±5% of Reading ± 3cts\u003cbr\u003e40GΩ to 10TΩ: ±15% of Reading ± 10cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDAR (1 min\/30 sec)\u003c\/td\u003e\n\u003ctd\u003e0.02 to 50.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePI (10 min\/1 min \u0026amp; user programmable)\u003c\/td\u003e\n\u003ctd\u003e0.02 to 50.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Measurement\u003c\/td\u003e\n\u003ctd\u003e0.005 to 49.99µF\u003cbr\u003eMax resolution 1nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current Measurement\u003c\/td\u003e\n\u003ctd\u003e0.00nA to 3mA\u003cbr\u003eMax resolution 1pA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Run Time R(t)\u003c\/td\u003e\n\u003ctd\u003e1 to 60 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge After Test\u003c\/td\u003e\n\u003ctd\u003eYes, automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge Voltage Display\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Test\/Safety Check\u003c\/td\u003e\n\u003ctd\u003e0 to 1000V AC\/DC (16 to 420Hz)\u003cbr\u003e1V Resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Megohmmeter\u003c\/li\u003e\n\u003cli\u003eSet of 6' Leads, 5000V (Red, Blue, and Black)\u003c\/li\u003e\n\u003cli\u003eSet of Alligator Clips, 600V CAT IV, (Red, Blue, and Black)\u003c\/li\u003e\n\u003cli\u003eBlue Guard Terminal Jumper Lead\u003c\/li\u003e\n\u003cli\u003eFuse, 0.1A 380V\u003c\/li\u003e\n\u003cli\u003eRechargeable Battery Pack\u003c\/li\u003e\n\u003cli\u003eUS 115V Power Cord\u003c\/li\u003e\n\u003cli\u003eExtra Large Tool Bag\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_6505_-_2130.18_-_5KV_Insulation_Tester_Spec.pdf?v=1609780939\" target=\"_blank\" title=\"AEMC 6505 Digital Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 6505 Digital Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 6505 Digital Megohmmeter w/ Analog Bargraph and Auto DAR/PI, 5000V

AEMC 6505 Digital Megohmmeter w/ Analog Bargraph and Auto DAR/PI, 5000V

$3,990.00 CAD

The Megohmmeter Model 6505 is a True Megohmmeter® portable instrument housed in a rugged field case that operates on either battery or line power. It performs voltage, insulation, and capacitance measurements. This instrument contributes to the safety of electrical installations and equipment. Features include automatic calculation and presentat...


More Info
{"id":6152267333822,"title":"AEMC 6526 Insulation Resistance Tester, 1kV with Bluetooth","handle":"aemc-6526-insulation-resistance-tester-200gω-with-bluetooth","description":"\u003cp\u003e\u003cspan\u003e1 kV megohmmeter measures voltage, frequency, resistance, and continuity, in addition to performing spot test and timed insulation resistance measurements at 5 selectable test voltages, and calculating PI and DAR ratios. Includes an onboard memory for 1300 measurements and Bluetooth wireless communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue Megohmmeter\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e1 kV Insulation and Multi-Function Tester (Resistance, Capacitance, Continuity, Frequency and Voltage)\u003c\/li\u003e\n\u003cli\u003e50V, 100V, 250V, 500V and 1000V Insulation Test Voltages\u003c\/li\u003e\n\u003cli\u003e200GΩ Max Insulation Resistance\u003c\/li\u003e\n\u003cli\u003eDAR and PI ratios calculated\u003c\/li\u003e\n\u003cli\u003eTimed Test Mode up to 40 minutes for Insulation Resistance Test\u003c\/li\u003e\n\u003cli\u003eTest Lock feature for hands free timed measurements up to 15 minutes\u003c\/li\u003e\n\u003cli\u003eContinuity tests at 20mA or 200mA\u003c\/li\u003e\n\u003cli\u003eTest lead resistance compensation for accurate low resistance measurements\u003c\/li\u003e\n\u003cli\u003eTrue RMS AC\/DC Voltmeter up to 700V\u003c\/li\u003e\n\u003cli\u003eOhmmeter to 1000kΩ\u003c\/li\u003e\n\u003cli\u003eCapacitance to 10µf\u003c\/li\u003e\n\u003cli\u003eFrequency measurements from 15 to 800Hz\u003c\/li\u003e\n\u003cli\u003eAuto discharge after Insulation Test\u003c\/li\u003e\n\u003cli\u003eHold function to \"freeze\" readings\u003c\/li\u003e\n\u003cli\u003eLarge and bright dual display with blue backlight\u003c\/li\u003e\n\u003cli\u003ePass\/Fail indicator with green\/red backlight\u003c\/li\u003e\n\u003cli\u003eAuto Standby Feature due to inactivity saves battery power\u003c\/li\u003e\n\u003cli\u003e1300 Measurement storage in memory\u003c\/li\u003e\n\u003cli\u003eBluetooth communication with included DataView software\u003c\/li\u003e\n\u003cli\u003eComplies with International Insulation Testing Standards including IEC\/EN 61557\u003c\/li\u003e\n\u003cli\u003e600V CAT IV\u003c\/li\u003e\n\u003cli\u003eOptional Remote Probe accessory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInsulation Tests\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e50, 100, 250, 500, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Ranges\u003c\/td\u003e\n\u003ctd\u003e50 V: 10k to 10GΩ\u003cbr\u003e100 V: 20k to 20GΩ\u003cbr\u003e250 V: 50k to 50GΩ\u003cbr\u003e500 V: 100k to 100GΩ\u003cbr\u003e1000 V: 200k to 200GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(3% + 2cts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage\u003c\/td\u003e\n\u003ctd\u003e0 + 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(3% + 3cts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Ranges\u003c\/td\u003e\n\u003ctd\u003e0.3 to 399.9 V, 400 to 700 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V, 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(3% + 2cts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e400kΩz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e300 Measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e6 x AA Alkaline Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.30 x 4.25 x 2.36\" (211 x 108 x 60 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.873 lbs (850 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Megohmmeter\u003c\/li\u003e\n\u003cli\u003e2 x 1.5 m Test Leads (Red and Black)\u003c\/li\u003e\n\u003cli\u003e2 x Alligator Clips (Red and Black)\u003c\/li\u003e\n\u003cli\u003eBlack Test Probe\u003c\/li\u003e\n\u003cli\u003e6 x AA Batteries\u003c\/li\u003e\n\u003cli\u003eUSB Stick with DataView\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eSoftware\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Pouch\u003c\/li\u003e\n\u003cli\u003eQuick Start Guide\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_6522_24_26_32_34_36_-_2155-53_Megommeters.pdf?v=1609774317\" target=\"_blank\" title=\"AEMC 6526 Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 6526 Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-04T08:34:36-07:00","created_at":"2021-01-04T08:26:42-07:00","vendor":"AEMC Instruments","type":"Insulation Testers","tags":[],"price":126000,"price_min":126000,"price_max":126000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37824864452798,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2155.53","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 6526 Insulation Resistance Tester, 1kV with Bluetooth","public_title":null,"options":["Default Title"],"price":126000,"weight":4082,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338150285","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6526Pic2.png?v=1609774631","\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6526Pic1.png?v=1609774631"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6526Pic2.png?v=1609774631","options":["Title"],"media":[{"alt":null,"id":15329398259902,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6526Pic2.png?v=1609774631"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6526Pic2.png?v=1609774631","width":650},{"alt":null,"id":15329391902910,"position":2,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6526Pic1.png?v=1609774631"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6526Pic1.png?v=1609774631","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003e1 kV megohmmeter measures voltage, frequency, resistance, and continuity, in addition to performing spot test and timed insulation resistance measurements at 5 selectable test voltages, and calculating PI and DAR ratios. Includes an onboard memory for 1300 measurements and Bluetooth wireless communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue Megohmmeter\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e1 kV Insulation and Multi-Function Tester (Resistance, Capacitance, Continuity, Frequency and Voltage)\u003c\/li\u003e\n\u003cli\u003e50V, 100V, 250V, 500V and 1000V Insulation Test Voltages\u003c\/li\u003e\n\u003cli\u003e200GΩ Max Insulation Resistance\u003c\/li\u003e\n\u003cli\u003eDAR and PI ratios calculated\u003c\/li\u003e\n\u003cli\u003eTimed Test Mode up to 40 minutes for Insulation Resistance Test\u003c\/li\u003e\n\u003cli\u003eTest Lock feature for hands free timed measurements up to 15 minutes\u003c\/li\u003e\n\u003cli\u003eContinuity tests at 20mA or 200mA\u003c\/li\u003e\n\u003cli\u003eTest lead resistance compensation for accurate low resistance measurements\u003c\/li\u003e\n\u003cli\u003eTrue RMS AC\/DC Voltmeter up to 700V\u003c\/li\u003e\n\u003cli\u003eOhmmeter to 1000kΩ\u003c\/li\u003e\n\u003cli\u003eCapacitance to 10µf\u003c\/li\u003e\n\u003cli\u003eFrequency measurements from 15 to 800Hz\u003c\/li\u003e\n\u003cli\u003eAuto discharge after Insulation Test\u003c\/li\u003e\n\u003cli\u003eHold function to \"freeze\" readings\u003c\/li\u003e\n\u003cli\u003eLarge and bright dual display with blue backlight\u003c\/li\u003e\n\u003cli\u003ePass\/Fail indicator with green\/red backlight\u003c\/li\u003e\n\u003cli\u003eAuto Standby Feature due to inactivity saves battery power\u003c\/li\u003e\n\u003cli\u003e1300 Measurement storage in memory\u003c\/li\u003e\n\u003cli\u003eBluetooth communication with included DataView software\u003c\/li\u003e\n\u003cli\u003eComplies with International Insulation Testing Standards including IEC\/EN 61557\u003c\/li\u003e\n\u003cli\u003e600V CAT IV\u003c\/li\u003e\n\u003cli\u003eOptional Remote Probe accessory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInsulation Tests\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e50, 100, 250, 500, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Ranges\u003c\/td\u003e\n\u003ctd\u003e50 V: 10k to 10GΩ\u003cbr\u003e100 V: 20k to 20GΩ\u003cbr\u003e250 V: 50k to 50GΩ\u003cbr\u003e500 V: 100k to 100GΩ\u003cbr\u003e1000 V: 200k to 200GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(3% + 2cts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage\u003c\/td\u003e\n\u003ctd\u003e0 + 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(3% + 3cts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Ranges\u003c\/td\u003e\n\u003ctd\u003e0.3 to 399.9 V, 400 to 700 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V, 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(3% + 2cts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e400kΩz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e300 Measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e6 x AA Alkaline Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.30 x 4.25 x 2.36\" (211 x 108 x 60 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.873 lbs (850 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Megohmmeter\u003c\/li\u003e\n\u003cli\u003e2 x 1.5 m Test Leads (Red and Black)\u003c\/li\u003e\n\u003cli\u003e2 x Alligator Clips (Red and Black)\u003c\/li\u003e\n\u003cli\u003eBlack Test Probe\u003c\/li\u003e\n\u003cli\u003e6 x AA Batteries\u003c\/li\u003e\n\u003cli\u003eUSB Stick with DataView\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eSoftware\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Pouch\u003c\/li\u003e\n\u003cli\u003eQuick Start Guide\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_6522_24_26_32_34_36_-_2155-53_Megommeters.pdf?v=1609774317\" target=\"_blank\" title=\"AEMC 6526 Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 6526 Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 6526 Insulation Resistance Tester, 1kV with Bluetooth

AEMC 6526 Insulation Resistance Tester, 1kV with Bluetooth

$1,260.00 CAD

1 kV megohmmeter measures voltage, frequency, resistance, and continuity, in addition to performing spot test and timed insulation resistance measurements at 5 selectable test voltages, and calculating PI and DAR ratios. Includes an onboard memory for 1300 measurements and Bluetooth wireless communication. Overview True Megohmmeter® 1 kV Ins...


More Info
AEMC 6528 Megohmmeter, 1000V

Insulation Testers

$419.00 CAD
{"id":6139450556606,"title":"AEMC 6528 Megohmmeter, 1000V","handle":"aemc-6528-megohmmeter-1000v","description":"\u003cp\u003eModel 6528 is a low cost 1000V hand-held instrument that offers Multimeter functions as well as Megohmmeter functions. This model is created for the commercial, industrial and contractor markets and is simple to use. It's priced at a point tailored to contractors and independent electricians that need to check the quality of insulation as well as perform basic electrical measurements.\u003c\/p\u003e\n\u003cp\u003eIt is a True Megohmmeter\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ein compliance with IEC 61010 and is designed with features and functions for use in the field: lightweight, compact, rugged and easy to handle, even when wearing gloves. Its construction and interface is intended to simplify use. An intuitive pass\/fail indication offering a blue\/red backlight makes it very easy to identify defective conditions.\u003c\/p\u003e\n\u003cp\u003eIt includes an automatic test inhibit if connected to a live circuit as well as automatic discharge at the completion of the test.\u003c\/p\u003e\n\u003cp\u003eA relative measurement function called DMR, unique to AEMC, provides the capability to compare measurements to a known reference quickly recognizing potential problems. Multimeter functions include AC\/DC voltage, resistance and continuity.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e• Selectable test voltages 250, 500 and 1000V (model 6528)\u003cbr data-mce-fragment=\"1\"\u003e• Selectable test voltages 50, 100, 250, 500 and 1000V (model 6529)\u003cbr data-mce-fragment=\"1\"\u003e• Basic DMM functions; Volts, Continuity, Resistance\u003cbr data-mce-fragment=\"1\"\u003e• DAR and PI ratio test functions (model 6529)\u003cbr data-mce-fragment=\"1\"\u003e• Dual line display to view the insulation value and real-time test voltage simultaneously in an easy to-read format\u003cbr data-mce-fragment=\"1\"\u003e• DMR mode - relative resistance comparison to a reference value\u003cbr data-mce-fragment=\"1\"\u003e• 2-color backlighting easily shows alarm conditions\u003cbr data-mce-fragment=\"1\"\u003e• Shockproof sheath for excellent handling\u003cbr data-mce-fragment=\"1\"\u003e• Automatic power-off function to optimize the battery life\u003cbr data-mce-fragment=\"1\"\u003e• Programmable alarm thresholds\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eAC\/DC Voltage Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e700V\u003csub\u003eAC\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand 700V\u003csub\u003eAC+DC\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003eDC: ± (1% R + 1ct)\u003cbr\u003eAC+DC: ± (1.2% R + 1ct)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003eDC \u0026amp; 30 to 440Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e 25MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eInsulation Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eTest Voltage \/ Resistance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e250V: 0.050MΩ to 4200MΩ\u003cbr\u003e500V: 0.100MΩ to 4200MΩ\u003cbr\u003e1000V: 0.20MΩ to 11.00GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e4MΩ\/40MΩ\/400MΩ: ± (1.5% R + 10ct)\u003cbr\u003e4.2GΩ: ± (4% R + 10ct)\u003cbr\u003e11GΩ: ± (10% R + 10ct) (1000V range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eContinuity Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eRanges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e0 to 40Ω (200mA test current ≤2Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e1.2% R + 3ct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eResolution max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e0.01Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eLeads compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003eUp to 5Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eThreshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003eAudible signal triggered Selectable ≤1 or 2Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eResistance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e0 to 420kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e± (1.2%R + 3ct)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eResolution max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eset of (2) 5' color-coded silicone leads\u003c\/li\u003e\n\u003cli\u003e(2) color-coded alligator clips\u003c\/li\u003e\n\u003cli\u003e(2) color-coded test probes (red\/black) (Rated 1000V CAT IV, UL V2)\u003c\/li\u003e\n\u003cli\u003esoft carrying case\u003c\/li\u003e\n\u003cli\u003e(6) 1.5V AA batteries\u003c\/li\u003e\n\u003cli\u003ea user manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_6528-6529_-_2126-54_Megohmmeter.pdf?v=1608829731\" target=\"_blank\" title=\"AEMC 6528 Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 6528 Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2020-12-24T10:21:51-07:00","created_at":"2020-12-24T10:21:50-07:00","vendor":"AEMC Instruments","type":"Insulation Testers","tags":[],"price":41900,"price_min":41900,"price_max":41900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37773031243966,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2126.54","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 6528 Megohmmeter, 1000V","public_title":null,"options":["Default Title"],"price":41900,"weight":907,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338150339","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6528Pic1.png?v=1608830512"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6528Pic1.png?v=1608830512","options":["Title"],"media":[{"alt":null,"id":15264727990462,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6528Pic1.png?v=1608830512"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6528Pic1.png?v=1608830512","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eModel 6528 is a low cost 1000V hand-held instrument that offers Multimeter functions as well as Megohmmeter functions. This model is created for the commercial, industrial and contractor markets and is simple to use. It's priced at a point tailored to contractors and independent electricians that need to check the quality of insulation as well as perform basic electrical measurements.\u003c\/p\u003e\n\u003cp\u003eIt is a True Megohmmeter\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ein compliance with IEC 61010 and is designed with features and functions for use in the field: lightweight, compact, rugged and easy to handle, even when wearing gloves. Its construction and interface is intended to simplify use. An intuitive pass\/fail indication offering a blue\/red backlight makes it very easy to identify defective conditions.\u003c\/p\u003e\n\u003cp\u003eIt includes an automatic test inhibit if connected to a live circuit as well as automatic discharge at the completion of the test.\u003c\/p\u003e\n\u003cp\u003eA relative measurement function called DMR, unique to AEMC, provides the capability to compare measurements to a known reference quickly recognizing potential problems. Multimeter functions include AC\/DC voltage, resistance and continuity.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e• Selectable test voltages 250, 500 and 1000V (model 6528)\u003cbr data-mce-fragment=\"1\"\u003e• Selectable test voltages 50, 100, 250, 500 and 1000V (model 6529)\u003cbr data-mce-fragment=\"1\"\u003e• Basic DMM functions; Volts, Continuity, Resistance\u003cbr data-mce-fragment=\"1\"\u003e• DAR and PI ratio test functions (model 6529)\u003cbr data-mce-fragment=\"1\"\u003e• Dual line display to view the insulation value and real-time test voltage simultaneously in an easy to-read format\u003cbr data-mce-fragment=\"1\"\u003e• DMR mode - relative resistance comparison to a reference value\u003cbr data-mce-fragment=\"1\"\u003e• 2-color backlighting easily shows alarm conditions\u003cbr data-mce-fragment=\"1\"\u003e• Shockproof sheath for excellent handling\u003cbr data-mce-fragment=\"1\"\u003e• Automatic power-off function to optimize the battery life\u003cbr data-mce-fragment=\"1\"\u003e• Programmable alarm thresholds\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eAC\/DC Voltage Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e700V\u003csub\u003eAC\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand 700V\u003csub\u003eAC+DC\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003eDC: ± (1% R + 1ct)\u003cbr\u003eAC+DC: ± (1.2% R + 1ct)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003eDC \u0026amp; 30 to 440Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e 25MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eInsulation Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eTest Voltage \/ Resistance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e250V: 0.050MΩ to 4200MΩ\u003cbr\u003e500V: 0.100MΩ to 4200MΩ\u003cbr\u003e1000V: 0.20MΩ to 11.00GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e4MΩ\/40MΩ\/400MΩ: ± (1.5% R + 10ct)\u003cbr\u003e4.2GΩ: ± (4% R + 10ct)\u003cbr\u003e11GΩ: ± (10% R + 10ct) (1000V range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eContinuity Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eRanges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e0 to 40Ω (200mA test current ≤2Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e1.2% R + 3ct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eResolution max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e0.01Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eLeads compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003eUp to 5Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eThreshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003eAudible signal triggered Selectable ≤1 or 2Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eResistance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e0 to 420kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e± (1.2%R + 3ct)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eResolution max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eset of (2) 5' color-coded silicone leads\u003c\/li\u003e\n\u003cli\u003e(2) color-coded alligator clips\u003c\/li\u003e\n\u003cli\u003e(2) color-coded test probes (red\/black) (Rated 1000V CAT IV, UL V2)\u003c\/li\u003e\n\u003cli\u003esoft carrying case\u003c\/li\u003e\n\u003cli\u003e(6) 1.5V AA batteries\u003c\/li\u003e\n\u003cli\u003ea user manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_6528-6529_-_2126-54_Megohmmeter.pdf?v=1608829731\" target=\"_blank\" title=\"AEMC 6528 Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 6528 Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 6528 Megohmmeter, 1000V

AEMC 6528 Megohmmeter, 1000V

$419.00 CAD

Model 6528 is a low cost 1000V hand-held instrument that offers Multimeter functions as well as Megohmmeter functions. This model is created for the commercial, industrial and contractor markets and is simple to use. It's priced at a point tailored to contractors and independent electricians that need to check the quality of insulation as well a...


More Info
AEMC 6529 Megohmmeter, 1000V

Insulation Testers

$489.00 CAD
{"id":6139470053566,"title":"AEMC 6529 Megohmmeter, 1000V","handle":"aemc-6529-megohmmeter-1000v","description":"\u003cp\u003eModel 6529 is a low cost 1000V hand-held instrument that offers Multimeter functions as well as Megohmmeter functions. This model is created for the commercial, industrial and contractor markets and is simple to use. It's priced at a point tailored to contractors and independent electricians that need to check the quality of insulation as well as perform basic electrical measurements.\u003c\/p\u003e\n\u003cp\u003eIt is a True Megohmmeter\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ein compliance with IEC 61010 and is designed with features and functions for use in the field: lightweight, compact, rugged and easy to handle, even when wearing gloves. Its construction and interface is intended to simplify use. An intuitive pass\/fail indication offering a blue\/red backlight makes it very easy to identify defective conditions.\u003c\/p\u003e\n\u003cp\u003eIt includes an automatic test inhibit if connected to a live circuit as well as automatic discharge at the completion of the test.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA relative measurement function called DMR, unique to AEMC, provides the capability to compare measurements to a known reference quickly recognizing potential problems. It includes Megohmmeter DAR and PI ratio test functions. Multimeter functions include AC\/DC voltage, resistance, continuity.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e• Selectable test voltages 250, 500 and 1000V (model 6528)\u003c\/p\u003e\n\u003cp\u003e• Selectable test voltages 50, 100, 250, 500 and 1000V (model 6529)\u003c\/p\u003e\n\u003cp\u003e• Basic DMM functions; Volts, Continuity, Resistance\u003c\/p\u003e\n\u003cp\u003e• DAR and PI ratio test functions (model 6529)\u003c\/p\u003e\n\u003cp\u003e• Dual line display to view the insulation value and real-time test voltage simultaneously in an easy to-read format\u003c\/p\u003e\n\u003cp\u003e• DMR mode - relative resistance comparison to a reference value\u003c\/p\u003e\n\u003cp\u003e• 2-color backlighting easily shows alarm conditions\u003c\/p\u003e\n\u003cp\u003e• Shockproof sheath for excellent handling\u003c\/p\u003e\n\u003cp\u003e• Automatic power-off function to optimize the battery life\u003c\/p\u003e\n\u003cp\u003e• Programmable alarm thresholds\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eAC\/DC Voltage Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e700V\u003csub\u003eAC\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand 700V\u003csub\u003eAC+DC\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003eDC: ± (1% R + 1ct)\u003cbr\u003eAC+DC: ± (1.2% R + 1ct)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003eDC \u0026amp; 30 to 440Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e 25MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eInsulation Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eTest Voltage \/ Resistance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e50V: 0.010 MΩ to 420.0MΩ\u003cbr\u003e100V: 0.020 MΩ to 420.0MΩ\u003cbr\u003e250V: 0.050MΩ to 4200MΩ\u003cbr\u003e500V: 0.100MΩ to 4200MΩ\u003cbr\u003e1000V: 0.20MΩ to 11.00GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e4MΩ\/40MΩ\/400MΩ: ± (1.5% R + 10ct)\u003cbr\u003e4.2GΩ: ± (4% R + 10ct)\u003cbr\u003e11GΩ: ± (10% R + 10ct) (1000V range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eContinuity Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eRanges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e0 to 40Ω (200mA test current ≤2Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e1.2% R + 3ct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eResolution max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e0.01Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eLeads compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003eUp to 5Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eThreshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003eAudible signal triggered Selectable ≤1 or 2Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eResistance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e0 to 420kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e± (1.2%R + 3ct)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eResolution max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eset of (2) 5' color-coded silicone leads\u003c\/li\u003e\n\u003cli\u003e(2) color-coded alligator clips\u003c\/li\u003e\n\u003cli\u003e(2) color-coded test probes (red\/black) (Rated 1000V CAT IV, UL V2)\u003c\/li\u003e\n\u003cli\u003esoft carrying case\u003c\/li\u003e\n\u003cli\u003e(6) 1.5V AA batteries\u003c\/li\u003e\n\u003cli\u003euser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_6528-6529_-_2126-54_Megohmmeter.pdf?v=1608829731\" target=\"_blank\" title=\"AEMC 6529 Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 6529 Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2020-12-24T10:59:55-07:00","created_at":"2020-12-24T10:59:54-07:00","vendor":"AEMC Instruments","type":"Insulation Testers","tags":[],"price":48900,"price_min":48900,"price_max":48900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37773153992894,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2126.55","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 6529 Megohmmeter, 1000V","public_title":null,"options":["Default Title"],"price":48900,"weight":907,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338150346","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6529Pic1.png?v=1608832798"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6529Pic1.png?v=1608832798","options":["Title"],"media":[{"alt":null,"id":15264842088638,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6529Pic1.png?v=1608832798"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6529Pic1.png?v=1608832798","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eModel 6529 is a low cost 1000V hand-held instrument that offers Multimeter functions as well as Megohmmeter functions. This model is created for the commercial, industrial and contractor markets and is simple to use. It's priced at a point tailored to contractors and independent electricians that need to check the quality of insulation as well as perform basic electrical measurements.\u003c\/p\u003e\n\u003cp\u003eIt is a True Megohmmeter\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ein compliance with IEC 61010 and is designed with features and functions for use in the field: lightweight, compact, rugged and easy to handle, even when wearing gloves. Its construction and interface is intended to simplify use. An intuitive pass\/fail indication offering a blue\/red backlight makes it very easy to identify defective conditions.\u003c\/p\u003e\n\u003cp\u003eIt includes an automatic test inhibit if connected to a live circuit as well as automatic discharge at the completion of the test.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA relative measurement function called DMR, unique to AEMC, provides the capability to compare measurements to a known reference quickly recognizing potential problems. It includes Megohmmeter DAR and PI ratio test functions. Multimeter functions include AC\/DC voltage, resistance, continuity.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e• Selectable test voltages 250, 500 and 1000V (model 6528)\u003c\/p\u003e\n\u003cp\u003e• Selectable test voltages 50, 100, 250, 500 and 1000V (model 6529)\u003c\/p\u003e\n\u003cp\u003e• Basic DMM functions; Volts, Continuity, Resistance\u003c\/p\u003e\n\u003cp\u003e• DAR and PI ratio test functions (model 6529)\u003c\/p\u003e\n\u003cp\u003e• Dual line display to view the insulation value and real-time test voltage simultaneously in an easy to-read format\u003c\/p\u003e\n\u003cp\u003e• DMR mode - relative resistance comparison to a reference value\u003c\/p\u003e\n\u003cp\u003e• 2-color backlighting easily shows alarm conditions\u003c\/p\u003e\n\u003cp\u003e• Shockproof sheath for excellent handling\u003c\/p\u003e\n\u003cp\u003e• Automatic power-off function to optimize the battery life\u003c\/p\u003e\n\u003cp\u003e• Programmable alarm thresholds\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eAC\/DC Voltage Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e700V\u003csub\u003eAC\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand 700V\u003csub\u003eAC+DC\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003eDC: ± (1% R + 1ct)\u003cbr\u003eAC+DC: ± (1.2% R + 1ct)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003eDC \u0026amp; 30 to 440Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e 25MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eInsulation Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eTest Voltage \/ Resistance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e50V: 0.010 MΩ to 420.0MΩ\u003cbr\u003e100V: 0.020 MΩ to 420.0MΩ\u003cbr\u003e250V: 0.050MΩ to 4200MΩ\u003cbr\u003e500V: 0.100MΩ to 4200MΩ\u003cbr\u003e1000V: 0.20MΩ to 11.00GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e4MΩ\/40MΩ\/400MΩ: ± (1.5% R + 10ct)\u003cbr\u003e4.2GΩ: ± (4% R + 10ct)\u003cbr\u003e11GΩ: ± (10% R + 10ct) (1000V range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eContinuity Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eRanges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e0 to 40Ω (200mA test current ≤2Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e1.2% R + 3ct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eResolution max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e0.01Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eLeads compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003eUp to 5Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eThreshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003eAudible signal triggered Selectable ≤1 or 2Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" colspan=\"2\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eResistance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e0 to 420kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e± (1.2%R + 3ct)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"345\" valign=\"top\"\u003e\u003cstrong\u003eResolution max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"932\" valign=\"top\"\u003e0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eset of (2) 5' color-coded silicone leads\u003c\/li\u003e\n\u003cli\u003e(2) color-coded alligator clips\u003c\/li\u003e\n\u003cli\u003e(2) color-coded test probes (red\/black) (Rated 1000V CAT IV, UL V2)\u003c\/li\u003e\n\u003cli\u003esoft carrying case\u003c\/li\u003e\n\u003cli\u003e(6) 1.5V AA batteries\u003c\/li\u003e\n\u003cli\u003euser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_6528-6529_-_2126-54_Megohmmeter.pdf?v=1608829731\" target=\"_blank\" title=\"AEMC 6529 Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 6529 Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 6529 Megohmmeter, 1000V

AEMC 6529 Megohmmeter, 1000V

$489.00 CAD

Model 6529 is a low cost 1000V hand-held instrument that offers Multimeter functions as well as Megohmmeter functions. This model is created for the commercial, industrial and contractor markets and is simple to use. It's priced at a point tailored to contractors and independent electricians that need to check the quality of insulation as well a...


More Info
{"id":6152318910654,"title":"AEMC 6536 Insulation Resistance Tester for ESD Testing, 10-100V","handle":"aemc-6536-insulation-resistance-tester-for-esd-testing-10-100v","description":"\u003cp\u003e\u003cspan\u003eIdeal for special applications in the aerospace and defense sectors. Also for ESD testing which require a low test voltage and strict adherence to testing procedures. This megohmmeter has features like a timer and lock function that allow you to operate it hands free. It has an automatic safety check that protects both the user and the meter with both audiovisual signals and a test inhibition when \u0026gt;25 V is registered. This megohmmeter is designed for special applications where the voltage needs to be set accurately in 1 V increments for testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue Megohmmeter\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e10 to 100V (variable) Insulation and Multi-Function Tester (Resistance, Continuity and Voltage)\u003c\/li\u003e\n\u003cli\u003eVariable 10 to 100V (1V increments) Insulation Test Voltages\u003c\/li\u003e\n\u003cli\u003e20GΩ Max Insulation Resistance\u003c\/li\u003e\n\u003cli\u003eTimed Test Mode up to 40 minutes for Insulation Resistance Test\u003c\/li\u003e\n\u003cli\u003eTest Lock feature for hands free timed measurements up to 15 minutes\u003c\/li\u003e\n\u003cli\u003eContinuity tests at 20mA or 200mA\u003c\/li\u003e\n\u003cli\u003eTest lead resistance compensation for accurate low resistance measurements\u003c\/li\u003e\n\u003cli\u003eTrue RMS AC\/DC Voltmeter up to 700V\u003c\/li\u003e\n\u003cli\u003eOhmmeter to 1000kΩ\u003c\/li\u003e\n\u003cli\u003eAuto discharge after Insulation Test\u003c\/li\u003e\n\u003cli\u003eHold function to \"freeze\" readings\u003c\/li\u003e\n\u003cli\u003eLarge and bright dual display with blue backlight\u003c\/li\u003e\n\u003cli\u003eAuto Standby Feature due to inactivity saves battery power\u003c\/li\u003e\n\u003cli\u003eOptional Remote Probe accessory\u003c\/li\u003e\n\u003cli\u003eElectro Static Discharge (ESD) Floor Test Kit for testing both point-to-ground and point-to-point electrostatic discharge\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Voltages\u003c\/td\u003e\n\u003ctd\u003eVariable 10 to 100 V (1 V steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 GΩ (20000 MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Test Inhibit\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;25 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDMM Voltage\u003c\/td\u003e\n\u003ctd\u003e700 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e1000 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e10 Ω, 100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Current\u003c\/td\u003e\n\u003ctd\u003e200\/20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Counts\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003e600 V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e6 x AA Alkaline Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Megohmmeter\u003c\/li\u003e\n\u003cli\u003e2 x 1.5m Test Leads (Red \u0026amp; Black)\u003c\/li\u003e\n\u003cli\u003e2 x Alligator clips (Red \u0026amp; Black)\u003c\/li\u003e\n\u003cli\u003e2 x Grip Probes (Red \u0026amp; Black)\u003c\/li\u003e\n\u003cli\u003eBlack Test Probe\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003cli\u003e6 x AA Alkaline Batteries\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_6522_24_26_32_34_36_-_2155-53_Megommeters.pdf?v=1609774317\" target=\"_blank\" title=\"AEMC 6536 Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 6536 Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-04T09:48:36-07:00","created_at":"2021-01-04T09:48:35-07:00","vendor":"AEMC Instruments","type":"Insulation Testers","tags":[],"price":229600,"price_min":229600,"price_max":229600,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37825280245950,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2155.57","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 6536 Insulation Resistance Tester for ESD Testing, 10-100V","public_title":null,"options":["Default Title"],"price":229600,"weight":9072,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338150322","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6536Pic1.png?v=1609778919","\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6536Pic2.png?v=1609778919","\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6536Pic3.jpg?v=1609778919"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6536Pic1.png?v=1609778919","options":["Title"],"media":[{"alt":null,"id":15329843511486,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6536Pic1.png?v=1609778919"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6536Pic1.png?v=1609778919","width":650},{"alt":null,"id":15329843544254,"position":2,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6536Pic2.png?v=1609778919"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6536Pic2.png?v=1609778919","width":650},{"alt":null,"id":15329843577022,"position":3,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6536Pic3.jpg?v=1609778919"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6536Pic3.jpg?v=1609778919","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eIdeal for special applications in the aerospace and defense sectors. Also for ESD testing which require a low test voltage and strict adherence to testing procedures. This megohmmeter has features like a timer and lock function that allow you to operate it hands free. It has an automatic safety check that protects both the user and the meter with both audiovisual signals and a test inhibition when \u0026gt;25 V is registered. This megohmmeter is designed for special applications where the voltage needs to be set accurately in 1 V increments for testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue Megohmmeter\u003csup\u003e®\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003e10 to 100V (variable) Insulation and Multi-Function Tester (Resistance, Continuity and Voltage)\u003c\/li\u003e\n\u003cli\u003eVariable 10 to 100V (1V increments) Insulation Test Voltages\u003c\/li\u003e\n\u003cli\u003e20GΩ Max Insulation Resistance\u003c\/li\u003e\n\u003cli\u003eTimed Test Mode up to 40 minutes for Insulation Resistance Test\u003c\/li\u003e\n\u003cli\u003eTest Lock feature for hands free timed measurements up to 15 minutes\u003c\/li\u003e\n\u003cli\u003eContinuity tests at 20mA or 200mA\u003c\/li\u003e\n\u003cli\u003eTest lead resistance compensation for accurate low resistance measurements\u003c\/li\u003e\n\u003cli\u003eTrue RMS AC\/DC Voltmeter up to 700V\u003c\/li\u003e\n\u003cli\u003eOhmmeter to 1000kΩ\u003c\/li\u003e\n\u003cli\u003eAuto discharge after Insulation Test\u003c\/li\u003e\n\u003cli\u003eHold function to \"freeze\" readings\u003c\/li\u003e\n\u003cli\u003eLarge and bright dual display with blue backlight\u003c\/li\u003e\n\u003cli\u003eAuto Standby Feature due to inactivity saves battery power\u003c\/li\u003e\n\u003cli\u003eOptional Remote Probe accessory\u003c\/li\u003e\n\u003cli\u003eElectro Static Discharge (ESD) Floor Test Kit for testing both point-to-ground and point-to-point electrostatic discharge\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Voltages\u003c\/td\u003e\n\u003ctd\u003eVariable 10 to 100 V (1 V steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 GΩ (20000 MΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Test Inhibit\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;25 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDMM Voltage\u003c\/td\u003e\n\u003ctd\u003e700 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e1000 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e10 Ω, 100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Current\u003c\/td\u003e\n\u003ctd\u003e200\/20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Counts\u003c\/td\u003e\n\u003ctd\u003e4000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003e600 V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e6 x AA Alkaline Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Megohmmeter\u003c\/li\u003e\n\u003cli\u003e2 x 1.5m Test Leads (Red \u0026amp; Black)\u003c\/li\u003e\n\u003cli\u003e2 x Alligator clips (Red \u0026amp; Black)\u003c\/li\u003e\n\u003cli\u003e2 x Grip Probes (Red \u0026amp; Black)\u003c\/li\u003e\n\u003cli\u003eBlack Test Probe\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003cli\u003e6 x AA Alkaline Batteries\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_6522_24_26_32_34_36_-_2155-53_Megommeters.pdf?v=1609774317\" target=\"_blank\" title=\"AEMC 6536 Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 6536 Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 6536 Insulation Resistance Tester for ESD Testing, 10-100V

AEMC 6536 Insulation Resistance Tester for ESD Testing, 10-100V

$2,296.00 CAD

Ideal for special applications in the aerospace and defense sectors. Also for ESD testing which require a low test voltage and strict adherence to testing procedures. This megohmmeter has features like a timer and lock function that allow you to operate it hands free. It has an automatic safety check that protects both the user and the meter wit...


More Info
{"id":6153724264638,"title":"AEMC 6550 Graphical Digital Megohmmeter with DataView Software, 10 kV","handle":"aemc-6550-graphical-digital-megohmmeter-with-dataview-software-10-kv","description":"\u003cp\u003eThe Megohmmeter Model 6550 is a high-end portable measuring instrument intended for the measurement of a wide variety of electrical insulation resistance values on cables and devices operating at high voltage. It is the only fully automated 10,000V graphical insulation tester. The True Megohmmeter\u003csup\u003e\u003cspan class=\"regmark\"\u003e®\u003c\/span\u003e\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eModel 6550 is packaged in a rugged case that is IP65 when closed. Test results and configuration information are displayed on a graphical LCD screen, and are exportable via DataView\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e(provided). This megohmmeter can operate on battery or AC power.\u003c\/p\u003e\n\u003cp\u003eThe Model 6550 also offers the ability to program up to three step voltage profiles (from 40 to 10,000V), each containing up to ten steps. There are also ramp profiles and three programmable test voltages in addition to the standard fixed voltages of 500, 1000, 2500, 5000 and 10,000V.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDetection and measurement of input voltage, frequency, and current prior to running a test\u003c\/li\u003e\n\u003cli\u003eMeasurements at a fixed test voltage of 500, 1000, 2500, 5000, 10,000 VDC\u003c\/li\u003e\n\u003cli\u003eRamp voltage measurements with a ramp from 40 to 1100 V\u003c\/li\u003e\n\u003cli\u003eStep voltage measurements with steps from 40 to 10,000 V\u003c\/li\u003e\n\u003cli\u003eNon-destructive (Early break) test, test stopped at a preset current (Break at I-limit) or burn mode with no predefined stop point\u003c\/li\u003e\n\u003cli\u003eDigital filtering of insulation measurements\u003c\/li\u003e\n\u003cli\u003eLive measurement of the voltage to warn the operator of potential unsafe conditions\u003c\/li\u003e\n\u003cli\u003eProgrammable thresholds to trigger audible\u003c\/li\u003e\n\u003cli\u003eTimed measurement duration checks\u003c\/li\u003e\n\u003cli\u003eFuse protection with display indication of defective fuse condition\u003c\/li\u003e\n\u003cli\u003eStores up to 80,000 measurements\u003c\/li\u003e\n\u003cli\u003eOptically-isolated USB communication for transfer onto PC and and report generation with the included DataView\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003esoftware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V: 10 kΩ to 2000 GΩ (2 TΩ)\u003cbr\u003e1000 V: 10 kΩ to 4000 GΩ (4 TΩ)\u003cbr\u003e2500 V: 10 kΩ to 10,000 GΩ (10 TΩ)\u003cbr\u003e5000 V: 10 kΩ to 15,000 GΩ (15 TΩ)\u003cbr\u003e10,000 V: 10 kΩ to 25,000 GΩ (25 TΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixed Test Voltages\u003c\/td\u003e\n\u003ctd\u003e500\/1000\/2500\/5000\/10,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariable Voltages\u003c\/td\u003e\n\u003ctd\u003e40 V to 10 kV Three user programmable voltage schemes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRamp Mode\u003c\/td\u003e\n\u003ctd\u003eProgrammable ramps: start voltage\/end voltage\/duration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRamp Configuration Range\u003c\/td\u003e\n\u003ctd\u003e40 to 1100 V\/500 to 10,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStep Mode\u003c\/td\u003e\n\u003ctd\u003eUp to 10 steps (voltage and duration configurable for each step)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Measurement After Test\u003c\/td\u003e\n\u003ctd\u003e0 to 2500 V AC\u003cbr\u003e0 to 4000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Measurement\u003c\/td\u003e\n\u003ctd\u003e0.05 to 9.999 µF\/10.00 to 49.99 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current Measurement\u003c\/td\u003e\n\u003ctd\u003e0 to 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge After Test\u003c\/td\u003e\n\u003ctd\u003eYes\/Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGraphical Digital Megohmmeter\u003c\/li\u003e\n\u003cli\u003eSmall, Classic Tool Bag\u003c\/li\u003e\n\u003cli\u003eSet of 3 9' Integral Leads (Red, Blue, and Black) and Alligator Clips, 1000 V CAT IV\u003c\/li\u003e\n\u003cli\u003eSet of 2 Test Probes (Red \u0026amp; Black), 1000 V CAT IV\u003c\/li\u003e\n\u003cli\u003eOptical USB Cable\u003c\/li\u003e\n\u003cli\u003eUS Power Cord, 115 V\u003c\/li\u003e\n\u003cli\u003e2 x NiMH Batteries\u003c\/li\u003e\n\u003cli\u003eUSB Stick with DataView Software and Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_6550_-_2130-31.pdf?v=1609865060\" target=\"_blank\" title=\"AEMC 6550 Graphical Digital Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 6550 Graphical Digital Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-05T09:51:54-07:00","created_at":"2021-01-05T09:51:52-07:00","vendor":"AEMC Instruments","type":"Insulation Testers","tags":[],"price":903000,"price_min":903000,"price_max":903000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37832072331454,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2130.31","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 6550 Graphical Digital Megohmmeter with DataView Software, 10 kV","public_title":null,"options":["Default Title"],"price":903000,"weight":11340,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338150247","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6550Pic1.png?v=1609865517"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6550Pic1.png?v=1609865517","options":["Title"],"media":[{"alt":null,"id":15338980966590,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6550Pic1.png?v=1609865517"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6550Pic1.png?v=1609865517","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe Megohmmeter Model 6550 is a high-end portable measuring instrument intended for the measurement of a wide variety of electrical insulation resistance values on cables and devices operating at high voltage. It is the only fully automated 10,000V graphical insulation tester. The True Megohmmeter\u003csup\u003e\u003cspan class=\"regmark\"\u003e®\u003c\/span\u003e\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eModel 6550 is packaged in a rugged case that is IP65 when closed. Test results and configuration information are displayed on a graphical LCD screen, and are exportable via DataView\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e(provided). This megohmmeter can operate on battery or AC power.\u003c\/p\u003e\n\u003cp\u003eThe Model 6550 also offers the ability to program up to three step voltage profiles (from 40 to 10,000V), each containing up to ten steps. There are also ramp profiles and three programmable test voltages in addition to the standard fixed voltages of 500, 1000, 2500, 5000 and 10,000V.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDetection and measurement of input voltage, frequency, and current prior to running a test\u003c\/li\u003e\n\u003cli\u003eMeasurements at a fixed test voltage of 500, 1000, 2500, 5000, 10,000 VDC\u003c\/li\u003e\n\u003cli\u003eRamp voltage measurements with a ramp from 40 to 1100 V\u003c\/li\u003e\n\u003cli\u003eStep voltage measurements with steps from 40 to 10,000 V\u003c\/li\u003e\n\u003cli\u003eNon-destructive (Early break) test, test stopped at a preset current (Break at I-limit) or burn mode with no predefined stop point\u003c\/li\u003e\n\u003cli\u003eDigital filtering of insulation measurements\u003c\/li\u003e\n\u003cli\u003eLive measurement of the voltage to warn the operator of potential unsafe conditions\u003c\/li\u003e\n\u003cli\u003eProgrammable thresholds to trigger audible\u003c\/li\u003e\n\u003cli\u003eTimed measurement duration checks\u003c\/li\u003e\n\u003cli\u003eFuse protection with display indication of defective fuse condition\u003c\/li\u003e\n\u003cli\u003eStores up to 80,000 measurements\u003c\/li\u003e\n\u003cli\u003eOptically-isolated USB communication for transfer onto PC and and report generation with the included DataView\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003esoftware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V: 10 kΩ to 2000 GΩ (2 TΩ)\u003cbr\u003e1000 V: 10 kΩ to 4000 GΩ (4 TΩ)\u003cbr\u003e2500 V: 10 kΩ to 10,000 GΩ (10 TΩ)\u003cbr\u003e5000 V: 10 kΩ to 15,000 GΩ (15 TΩ)\u003cbr\u003e10,000 V: 10 kΩ to 25,000 GΩ (25 TΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixed Test Voltages\u003c\/td\u003e\n\u003ctd\u003e500\/1000\/2500\/5000\/10,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariable Voltages\u003c\/td\u003e\n\u003ctd\u003e40 V to 10 kV Three user programmable voltage schemes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRamp Mode\u003c\/td\u003e\n\u003ctd\u003eProgrammable ramps: start voltage\/end voltage\/duration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRamp Configuration Range\u003c\/td\u003e\n\u003ctd\u003e40 to 1100 V\/500 to 10,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStep Mode\u003c\/td\u003e\n\u003ctd\u003eUp to 10 steps (voltage and duration configurable for each step)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Measurement After Test\u003c\/td\u003e\n\u003ctd\u003e0 to 2500 V AC\u003cbr\u003e0 to 4000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Measurement\u003c\/td\u003e\n\u003ctd\u003e0.05 to 9.999 µF\/10.00 to 49.99 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current Measurement\u003c\/td\u003e\n\u003ctd\u003e0 to 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge After Test\u003c\/td\u003e\n\u003ctd\u003eYes\/Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGraphical Digital Megohmmeter\u003c\/li\u003e\n\u003cli\u003eSmall, Classic Tool Bag\u003c\/li\u003e\n\u003cli\u003eSet of 3 9' Integral Leads (Red, Blue, and Black) and Alligator Clips, 1000 V CAT IV\u003c\/li\u003e\n\u003cli\u003eSet of 2 Test Probes (Red \u0026amp; Black), 1000 V CAT IV\u003c\/li\u003e\n\u003cli\u003eOptical USB Cable\u003c\/li\u003e\n\u003cli\u003eUS Power Cord, 115 V\u003c\/li\u003e\n\u003cli\u003e2 x NiMH Batteries\u003c\/li\u003e\n\u003cli\u003eUSB Stick with DataView Software and Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_6550_-_2130-31.pdf?v=1609865060\" target=\"_blank\" title=\"AEMC 6550 Graphical Digital Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 6550 Graphical Digital Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 6550 Graphical Digital Megohmmeter with DataView Software, 10 kV

AEMC 6550 Graphical Digital Megohmmeter with DataView Software, 10 kV

$9,030.00 CAD

The Megohmmeter Model 6550 is a high-end portable measuring instrument intended for the measurement of a wide variety of electrical insulation resistance values on cables and devices operating at high voltage. It is the only fully automated 10,000V graphical insulation tester. The True Megohmmeter® Model 6550 is packaged in a rugged case that is...


More Info
{"id":6153730523326,"title":"AEMC 6555 Graphical Digital Megohmmeter with DataView Software, 15 kV","handle":"aemc-6555-graphical-digital-megohmmeter-with-dataview-software-15-kv","description":"\u003cp\u003eThe Megohmmeter Model 6555 is a high-end portable measuring instrument intended for the measurement of a wide variety of electrical insulation resistance values on cables and devices operating at high voltage. It is the only fully automated 15,000V graphical insulation tester. The True Megohmmeter\u003csup\u003e\u003cspan class=\"regmark\"\u003e®\u003c\/span\u003e\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eModel 6555 is packaged in a rugged case that is IP65 when closed. Test results and configuration information are displayed on a graphical LCD screen and are exportable via DataView\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e(provided). This megohmmeter can operate on battery or AC power.\u003c\/p\u003e\n\u003cp\u003eThe Model 6555 also offers the ability to program up to three step voltage profiles (from 40 to 15,000V), each containing up to ten steps. There are also three ramp profiles and three programmable test voltages in addition to the standard fixed voltages of 500, 1000, 2500, 5000, 10,000 and 15,000V.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDetection and measurement of input voltage, frequency, and current prior to running a test\u003c\/li\u003e\n\u003cli\u003eMeasurements at a fixed test voltage of 500, 1000, 2500, 5000, 10,000 or 15,000 V DC\u003c\/li\u003e\n\u003cli\u003eMeasurements at an adjustable test voltage between 40 and 15,000VDC\u003c\/li\u003e\n\u003cli\u003eRamp voltage measurements with a ramp from 40 to 1100V or from 500 to 15,000 V\u003c\/li\u003e\n\u003cli\u003eStep voltage measurements with steps from 40 to 15,000V\u003c\/li\u003e\n\u003cli\u003eNon-destructive (Early break) test, test stopped at a preset current (Break at I-limit) or Burn mode with no predefined stop point\u003c\/li\u003e\n\u003cli\u003eDigital filtering of insulation measurements\u003c\/li\u003e\n\u003cli\u003eLive measurement of the voltage to warn the operator of potential unsafe conditions\u003c\/li\u003e\n\u003cli\u003eProgrammable thresholds to trigger audible\u003c\/li\u003e\n\u003cli\u003eTimed measurement duration checks\u003c\/li\u003e\n\u003cli\u003eFuse protection with display indication of defective fuse condition\u003c\/li\u003e\n\u003cli\u003eStores up to 80,000 measurements\u003c\/li\u003e\n\u003cli\u003eOptically-isolated USB communication for transfer onto PC and and report generation with the included\u003c\/li\u003e\n\u003cli\u003eDataView\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003esoftware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V: 10 kΩ to 2000 GΩ (2 TΩ)\u003cbr\u003e1000 V: 10 kΩ to 4000 GΩ (4 TΩ)\u003cbr\u003e2500 V: 10 kΩ to 10,000 GΩ (10 TΩ)\u003cbr\u003e5000 V: 10 kΩ to 15,000 GΩ (15 TΩ)\u003cbr\u003e10,000 V: 10 kΩ to 25,000 GΩ (25 TΩ)\u003cbr\u003e15,000 V: 10 kΩ to 25,000 GΩ (25 TΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixed Test Voltages\u003c\/td\u003e\n\u003ctd\u003e500\/1000\/2500\/5000\/10,000\/15,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariable Voltages\u003c\/td\u003e\n\u003ctd\u003e40 V to 15 kV Three user programmable voltage schemes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRamp Mode\u003c\/td\u003e\n\u003ctd\u003eProgrammable ramps: start voltage\/end voltage\/duration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRamp Configuration Range\u003c\/td\u003e\n\u003ctd\u003e40 to 1100 V\/500 to 15,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStep Mode\u003c\/td\u003e\n\u003ctd\u003eUp to 10 steps (voltage and duration configurable for each step)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Measurement After Test\u003c\/td\u003e\n\u003ctd\u003e0 to 2500 V AC\u003cbr\u003e0 to 4000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Measurement\u003c\/td\u003e\n\u003ctd\u003e0.05 to 9.999 µF\/10.00 to 49.99 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current Measurement\u003c\/td\u003e\n\u003ctd\u003e0 to 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge After Test\u003c\/td\u003e\n\u003ctd\u003eYes\/Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGraphical Digital Megohmmeter\u003c\/li\u003e\n\u003cli\u003eSet of 3 9' Integral Leads (Red, Blue, and Black) and Alligator Clips, 1000 V CAT IV\u003c\/li\u003e\n\u003cli\u003eSet of 2 Test Probes (Red \u0026amp; Black), 1000 V CAT IV\u003c\/li\u003e\n\u003cli\u003eOptical USB Cable\u003c\/li\u003e\n\u003cli\u003eUS Power Cord, 115 V\u003c\/li\u003e\n\u003cli\u003eSmall, Classic Tool Bag\u003c\/li\u003e\n\u003cli\u003e2 x NiMH Batteries\u003c\/li\u003e\n\u003cli\u003eUSB Stick with DataView Software and Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_6555_-_2130-32.pdf?v=1609865802\" target=\"_blank\" title=\"AEMC 6555 Graphical Digital Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 6555 Graphical Digital Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-05T10:00:47-07:00","created_at":"2021-01-05T10:00:46-07:00","vendor":"AEMC Instruments","type":"Insulation Testers","tags":[],"price":1015000,"price_min":1015000,"price_max":1015000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37832098644158,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2130.32","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 6555 Graphical Digital Megohmmeter with DataView Software, 15 kV","public_title":null,"options":["Default Title"],"price":1015000,"weight":11340,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338150254","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6555Pic1.png?v=1609866050"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6555Pic1.png?v=1609866050","options":["Title"],"media":[{"alt":null,"id":15339017633982,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6555Pic1.png?v=1609866050"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6555Pic1.png?v=1609866050","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe Megohmmeter Model 6555 is a high-end portable measuring instrument intended for the measurement of a wide variety of electrical insulation resistance values on cables and devices operating at high voltage. It is the only fully automated 15,000V graphical insulation tester. The True Megohmmeter\u003csup\u003e\u003cspan class=\"regmark\"\u003e®\u003c\/span\u003e\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eModel 6555 is packaged in a rugged case that is IP65 when closed. Test results and configuration information are displayed on a graphical LCD screen and are exportable via DataView\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e(provided). This megohmmeter can operate on battery or AC power.\u003c\/p\u003e\n\u003cp\u003eThe Model 6555 also offers the ability to program up to three step voltage profiles (from 40 to 15,000V), each containing up to ten steps. There are also three ramp profiles and three programmable test voltages in addition to the standard fixed voltages of 500, 1000, 2500, 5000, 10,000 and 15,000V.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDetection and measurement of input voltage, frequency, and current prior to running a test\u003c\/li\u003e\n\u003cli\u003eMeasurements at a fixed test voltage of 500, 1000, 2500, 5000, 10,000 or 15,000 V DC\u003c\/li\u003e\n\u003cli\u003eMeasurements at an adjustable test voltage between 40 and 15,000VDC\u003c\/li\u003e\n\u003cli\u003eRamp voltage measurements with a ramp from 40 to 1100V or from 500 to 15,000 V\u003c\/li\u003e\n\u003cli\u003eStep voltage measurements with steps from 40 to 15,000V\u003c\/li\u003e\n\u003cli\u003eNon-destructive (Early break) test, test stopped at a preset current (Break at I-limit) or Burn mode with no predefined stop point\u003c\/li\u003e\n\u003cli\u003eDigital filtering of insulation measurements\u003c\/li\u003e\n\u003cli\u003eLive measurement of the voltage to warn the operator of potential unsafe conditions\u003c\/li\u003e\n\u003cli\u003eProgrammable thresholds to trigger audible\u003c\/li\u003e\n\u003cli\u003eTimed measurement duration checks\u003c\/li\u003e\n\u003cli\u003eFuse protection with display indication of defective fuse condition\u003c\/li\u003e\n\u003cli\u003eStores up to 80,000 measurements\u003c\/li\u003e\n\u003cli\u003eOptically-isolated USB communication for transfer onto PC and and report generation with the included\u003c\/li\u003e\n\u003cli\u003eDataView\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003esoftware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V: 10 kΩ to 2000 GΩ (2 TΩ)\u003cbr\u003e1000 V: 10 kΩ to 4000 GΩ (4 TΩ)\u003cbr\u003e2500 V: 10 kΩ to 10,000 GΩ (10 TΩ)\u003cbr\u003e5000 V: 10 kΩ to 15,000 GΩ (15 TΩ)\u003cbr\u003e10,000 V: 10 kΩ to 25,000 GΩ (25 TΩ)\u003cbr\u003e15,000 V: 10 kΩ to 25,000 GΩ (25 TΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixed Test Voltages\u003c\/td\u003e\n\u003ctd\u003e500\/1000\/2500\/5000\/10,000\/15,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVariable Voltages\u003c\/td\u003e\n\u003ctd\u003e40 V to 15 kV Three user programmable voltage schemes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRamp Mode\u003c\/td\u003e\n\u003ctd\u003eProgrammable ramps: start voltage\/end voltage\/duration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRamp Configuration Range\u003c\/td\u003e\n\u003ctd\u003e40 to 1100 V\/500 to 15,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStep Mode\u003c\/td\u003e\n\u003ctd\u003eUp to 10 steps (voltage and duration configurable for each step)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Measurement After Test\u003c\/td\u003e\n\u003ctd\u003e0 to 2500 V AC\u003cbr\u003e0 to 4000 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Measurement\u003c\/td\u003e\n\u003ctd\u003e0.05 to 9.999 µF\/10.00 to 49.99 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current Measurement\u003c\/td\u003e\n\u003ctd\u003e0 to 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge After Test\u003c\/td\u003e\n\u003ctd\u003eYes\/Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGraphical Digital Megohmmeter\u003c\/li\u003e\n\u003cli\u003eSet of 3 9' Integral Leads (Red, Blue, and Black) and Alligator Clips, 1000 V CAT IV\u003c\/li\u003e\n\u003cli\u003eSet of 2 Test Probes (Red \u0026amp; Black), 1000 V CAT IV\u003c\/li\u003e\n\u003cli\u003eOptical USB Cable\u003c\/li\u003e\n\u003cli\u003eUS Power Cord, 115 V\u003c\/li\u003e\n\u003cli\u003eSmall, Classic Tool Bag\u003c\/li\u003e\n\u003cli\u003e2 x NiMH Batteries\u003c\/li\u003e\n\u003cli\u003eUSB Stick with DataView Software and Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_6555_-_2130-32.pdf?v=1609865802\" target=\"_blank\" title=\"AEMC 6555 Graphical Digital Megohmmeter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 6555 Graphical Digital Megohmmeter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 6555 Graphical Digital Megohmmeter with DataView Software, 15 kV

AEMC 6555 Graphical Digital Megohmmeter with DataView Software, 15 kV

$10,150.00 CAD

The Megohmmeter Model 6555 is a high-end portable measuring instrument intended for the measurement of a wide variety of electrical insulation resistance values on cables and devices operating at high voltage. It is the only fully automated 15,000V graphical insulation tester. The True Megohmmeter® Model 6555 is packaged in a rugged case that is...


More Info
{"id":1289633366059,"title":"Amprobe AMB-25 Digital Insulation Resistance Tester","handle":"amprobe-amb-25-digital-insulation-resistance-tester","description":"This affordable and rugged megohmmeters are fast and easy to use, and offer the features you need for most insulation test applications including wires, cables, transformers, and motors.","published_at":"2018-05-29T16:04:11-06:00","created_at":"2018-05-29T16:06:46-06:00","vendor":"Amprobe","type":"Insulation Testers","tags":[],"price":72198,"price_min":72198,"price_max":72198,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12314522845227,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"Amprobe AMB-25","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Amprobe AMB-25 Digital Insulation Resistance Tester","public_title":null,"options":["Default Title"],"price":72198,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969366090","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AMB_25.jpg?v=1527631608"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AMB_25.jpg?v=1527631608","options":["Title"],"media":[{"alt":null,"id":1687445602347,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AMB_25.jpg?v=1527631608"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AMB_25.jpg?v=1527631608","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"This affordable and rugged megohmmeters are fast and easy to use, and offer the features you need for most insulation test applications including wires, cables, transformers, and motors."}
Amprobe AMB-25 Digital Insulation Resistance Tester

Amprobe AMB-25 Digital Insulation Resistance Tester

$721.98 CAD

This affordable and rugged megohmmeters are fast and easy to use, and offer the features you need for most insulation test applications including wires, cables, transformers, and motors.


More Info
Amprobe AMB-45 Insulation Resistance Tester

Insulation Testers

$1,117.91 CAD
{"id":1289667248171,"title":"Amprobe AMB-45 Insulation Resistance Tester","handle":"amprobe-amb-45-insulation-resistance-tester","description":"Test insulation of wires, cables, transformers and electrical motors quickly and easily with this rugged tester.","published_at":"2018-05-29T16:41:23-06:00","created_at":"2018-05-29T16:44:50-06:00","vendor":"Amprobe","type":"Insulation Testers","tags":[],"price":111791,"price_min":111791,"price_max":111791,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12315053883435,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"Amprobe AMB-45","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Amprobe AMB-45 Insulation Resistance Tester","public_title":null,"options":["Default Title"],"price":111791,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969366120","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AMP2731024.jpg?v=1527633892"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AMP2731024.jpg?v=1527633892","options":["Title"],"media":[{"alt":null,"id":1687538630699,"position":1,"preview_image":{"aspect_ratio":1.24,"height":900,"width":1116,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AMP2731024.jpg?v=1527633892"},"aspect_ratio":1.24,"height":900,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AMP2731024.jpg?v=1527633892","width":1116}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"Test insulation of wires, cables, transformers and electrical motors quickly and easily with this rugged tester."}
Amprobe AMB-45 Insulation Resistance Tester

Amprobe AMB-45 Insulation Resistance Tester

$1,117.91 CAD

Test insulation of wires, cables, transformers and electrical motors quickly and easily with this rugged tester.


More Info
Amprobe LCR55A Capacitance Tester

Insulation Testers

$535.83 CAD
{"id":1289610625067,"title":"Amprobe LCR55A Capacitance Tester","handle":"amprobe-lcr55a-capacitance-tester","description":"The ultimate electronic component verifier measures inductance, capacitance, resistance, transistors, diodes and microwave diodes.","published_at":"2018-05-29T15:28:21-06:00","created_at":"2018-05-29T15:41:07-06:00","vendor":"Amprobe","type":"Insulation Testers","tags":[],"price":53583,"price_min":53583,"price_max":53583,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12314166165547,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"Amprobe LCR55A","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Amprobe LCR55A Capacitance Tester","public_title":null,"options":["Default Title"],"price":53583,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969414753","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/1YBT6_AS01.jpg?v=1527630069"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/1YBT6_AS01.jpg?v=1527630069","options":["Title"],"media":[{"alt":null,"id":1687382130731,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/1YBT6_AS01.jpg?v=1527630069"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/1YBT6_AS01.jpg?v=1527630069","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"The ultimate electronic component verifier measures inductance, capacitance, resistance, transistors, diodes and microwave diodes."}
Amprobe LCR55A Capacitance Tester

Amprobe LCR55A Capacitance Tester

$535.83 CAD

The ultimate electronic component verifier measures inductance, capacitance, resistance, transistors, diodes and microwave diodes.


More Info
Fluke 1503 Insulation Resistance Tester

Insulation Testers

$990.07 CAD
{"id":1076161151019,"title":"Fluke 1503 Insulation Resistance Tester","handle":"fluke-1503-insulation-resistance-tester","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 1503 is a great choice for basic residential and commercial electrical insulation testing. This rugged, compact tool fits in the palm of your hand. The 1503 is the same form factor as the Fluke 1507 but with a few less features. You can count on it to handle the most common tests at a most affordable price. Additional features, like the remote probe, reduce the time needed to perform repetitive testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eA rugged, compact insulation resistance tester for residential and commercial electricians\u003c\/li\u003e\n\u003cli\u003ePerforms insulation tests from 0.01 MΩ to 2000 MΩ\u003c\/li\u003e\n\u003cli\u003eOffers two insulation test voltages: 500 V and 1000 V\u003c\/li\u003e\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli\u003eMeasures resistance from 0.01 Ω to 20.00 kΩ\\\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures AC\/DC voltage from 0.1 V to 600 V\u003c\/li\u003e\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli\u003eProvides lo-ohms earth-bond continuity (200 mA)\u003c\/li\u003e\n\u003cli\u003eSimplifies repetitive or hard-to-reach testing with the remote test probe\u003c\/li\u003e\n\u003cli\u003eSaves battery power with auto power off\u003c\/li\u003e\n\u003cli\u003ePresents results on a large, backlit display\u003c\/li\u003e\n\u003cli\u003eFeatures CAT IV 600 V overvoltage category rating\u003c\/li\u003e\n\u003cli\u003eComes with remote probe, test leads, test probes, alligator clips, and one-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC\/DC Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 Hz to 400 Hz ±(% of Rdg + Digits)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 MΩ (nominal), \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio (1 kΩ unbalanced)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 60 dB at DC, 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEarth Bond Resistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e20.00 Ω\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200.0 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003e1.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit test voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 4.0 V, \u0026lt; 8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 200.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInsulation Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 MΩ to 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+ 20%, - 0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto discharge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDischarge time \u0026lt; 0.5 second for C = 1 µF or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive circuit indicator\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInhibit test if terminal voltage \u0026gt; 30 V prior to initialization of test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOperable with up to 1 µF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eMeasure accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage applied to any terminal:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V AC rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.05 x (specified accuracy) per °C for temperatures \u0026lt; 18°C or \u0026gt; 28°C (\u0026lt; 64°F or \u0026gt; 82°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRelative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 95% @ 10°C to 30°C (50°F to 86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 75% @ 30°C to 40°C (86°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 40% @ 40°C to 55°C (104°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIn an RF field of 3 V\/M, accuracy = specified accuracy (EN 61326-1:1997)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eComplies with ANSI\/ISA 82.02.01 (61010-1) 2004, CAN\/CSA-C22.2 NO. 61010-1-04, and IEC\/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA per standard CSA\/CAN C22.2 No. 61010.1-04; TUV per standard IEC\/EN 61010-1 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFour AA batteries (NEDA 15A or IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery llife\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eInsulation test use:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance measurements:\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOperating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m CAT IV 600 V, 3000 m CAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating (storage)\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-range capability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e110% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded accessories\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1503 Insulation Tester\u003c\/li\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eTest probes\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1507_and_1503_Spec.pdf?1803\" target=\"_blank\" title=\"Fluke 1503 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1503 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2018-03-07T12:57:54-07:00","created_at":"2018-03-07T13:24:58-07:00","vendor":"Fluke","type":"Insulation Testers","tags":[],"price":99007,"price_min":99007,"price_max":99007,"available":true,"price_varies":false,"compare_at_price":70700,"compare_at_price_min":70700,"compare_at_price_max":70700,"compare_at_price_varies":false,"variants":[{"id":11042039562283,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-1503","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1503 Insulation Resistance Tester","public_title":null,"options":["Default Title"],"price":99007,"weight":2268,"compare_at_price":70700,"inventory_management":"shopify","barcode":"095969288668","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1503_BHD.jpg?v=1520454300"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1503_BHD.jpg?v=1520454300","options":["Title"],"media":[{"alt":null,"id":1475812065323,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1503_BHD.jpg?v=1520454300"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1503_BHD.jpg?v=1520454300","width":1200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 1503 is a great choice for basic residential and commercial electrical insulation testing. This rugged, compact tool fits in the palm of your hand. The 1503 is the same form factor as the Fluke 1507 but with a few less features. You can count on it to handle the most common tests at a most affordable price. Additional features, like the remote probe, reduce the time needed to perform repetitive testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eA rugged, compact insulation resistance tester for residential and commercial electricians\u003c\/li\u003e\n\u003cli\u003ePerforms insulation tests from 0.01 MΩ to 2000 MΩ\u003c\/li\u003e\n\u003cli\u003eOffers two insulation test voltages: 500 V and 1000 V\u003c\/li\u003e\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli\u003eMeasures resistance from 0.01 Ω to 20.00 kΩ\\\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures AC\/DC voltage from 0.1 V to 600 V\u003c\/li\u003e\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli\u003eProvides lo-ohms earth-bond continuity (200 mA)\u003c\/li\u003e\n\u003cli\u003eSimplifies repetitive or hard-to-reach testing with the remote test probe\u003c\/li\u003e\n\u003cli\u003eSaves battery power with auto power off\u003c\/li\u003e\n\u003cli\u003ePresents results on a large, backlit display\u003c\/li\u003e\n\u003cli\u003eFeatures CAT IV 600 V overvoltage category rating\u003c\/li\u003e\n\u003cli\u003eComes with remote probe, test leads, test probes, alligator clips, and one-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC\/DC Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 Hz to 400 Hz ±(% of Rdg + Digits)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 MΩ (nominal), \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio (1 kΩ unbalanced)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 60 dB at DC, 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEarth Bond Resistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e20.00 Ω\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200.0 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003e1.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit test voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 4.0 V, \u0026lt; 8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 200.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInsulation Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 MΩ to 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+ 20%, - 0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto discharge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDischarge time \u0026lt; 0.5 second for C = 1 µF or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive circuit indicator\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInhibit test if terminal voltage \u0026gt; 30 V prior to initialization of test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOperable with up to 1 µF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eMeasure accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage applied to any terminal:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V AC rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.05 x (specified accuracy) per °C for temperatures \u0026lt; 18°C or \u0026gt; 28°C (\u0026lt; 64°F or \u0026gt; 82°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRelative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 95% @ 10°C to 30°C (50°F to 86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 75% @ 30°C to 40°C (86°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 40% @ 40°C to 55°C (104°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIn an RF field of 3 V\/M, accuracy = specified accuracy (EN 61326-1:1997)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eComplies with ANSI\/ISA 82.02.01 (61010-1) 2004, CAN\/CSA-C22.2 NO. 61010-1-04, and IEC\/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA per standard CSA\/CAN C22.2 No. 61010.1-04; TUV per standard IEC\/EN 61010-1 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFour AA batteries (NEDA 15A or IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery llife\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eInsulation test use:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance measurements:\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOperating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m CAT IV 600 V, 3000 m CAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating (storage)\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-range capability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e110% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded accessories\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1503 Insulation Tester\u003c\/li\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eTest probes\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1507_and_1503_Spec.pdf?1803\" target=\"_blank\" title=\"Fluke 1503 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1503 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e"}
Fluke 1503 Insulation Resistance Tester

Fluke 1503 Insulation Resistance Tester

$990.07 CAD

The Fluke 1503 is a great choice for basic residential and commercial electrical insulation testing. This rugged, compact tool fits in the palm of your hand. The 1503 is the same form factor as the Fluke 1507 but with a few less features. You can count on it to handle the most common tests at a most affordable price. Additional features, like t...


More Info
Fluke 1507 Insulation Resistance Tester

Insulation Testers

$1,165.51 CAD
{"id":1076405272619,"title":"Fluke 1507 Insulation Resistance Tester","handle":"fluke-1507-insulation-resistance-tester","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications.\u003c\/p\u003e\n\u003cp\u003eTake advantage of the 1507 full feature set to easily and quickly perform advanced insulation resistance testing. Its handy size and light weight make it easy to pack and use. Additional features, like the remote probe, save both time and money especially when performing repetitive tests. And its reasonable price and rugged reliability make it an excellent value.\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRugged, compact advanced insulation resistance tester for electrical contractors and industrial and commercial electricians\u003c\/li\u003e\n\u003cli\u003eAutomatically calculates Polarization Index and Dielectric Absorption Ratio\u003c\/li\u003e\n\u003cli\u003eMakes repetitive tests simple and easy with a Compare (Pass\/Fail) function \u003c\/li\u003e\n\u003cli\u003eOffers multiple insulation test voltages: 50 V, 100 V, 250 V, 500 V, and  1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePerforms insulation tests from 0.01 MΩ to 2.0 GΩ\u003c\/li\u003e\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage from 0.1 V to 600 V and resistance from 0.01 Ω to 20.00 kΩ\u003c\/li\u003e\n\u003cli\u003eProvides lo-ohms earth-bond continuity (200 mA)\u003c\/li\u003e\n\u003cli\u003eSimplifies repetitive or hard-to-reach testing with the remote test probe\u003c\/li\u003e\n\u003cli\u003eSaves battery power with auto power off\u003c\/li\u003e\n\u003cli\u003ePresents results on a large, backlit display\u003c\/li\u003e\n\u003cli\u003eFeatures CAT IV 600 V overvoltage category rating\u003c\/li\u003e\n\u003cli\u003eComes with remote probe, test leads, test probes, alligator clips and one-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC\/DC Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 Hz to 400 Hz ± (% of Rdg + Digits)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 MΩ (nominal), \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio (1 kΩ unbalanced):\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 60 dB at DC, 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEarth Bond Resistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e20.00 Ω\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200.0 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003e1.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit test voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 4.0 V, \u0026lt; 8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 200.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInsulation Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+ 20%, - 0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto discharge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDischarge time \u0026lt; 0.5 second for C = 1 µF or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive circuit indicator\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInhibit test if terminal voltage \u0026gt; 30 V prior to initialization of test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOperable with up to 1 µF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eMeasure accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e50 V\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage applied to any terminal:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V AC rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.05 x (specified accuracy) per °C for temperatures \u0026lt; 18°C or \u0026gt; 28°C (\u0026lt; 64°F or \u0026gt; 82°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRelative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 95% @ 10°C to 30°C (50°F to 86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 75% @ 30°C to 40°C (86°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 40% @ 40°C to 55°C (104°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIn an RF field of 3 V\/M, accuracy = specified accuracy (EN 61326-1:1997)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eComplies with ANSI\/ISA 82.02.01 (61010-1) 2004, CAN\/CSA-C22.2 NO. 61010-1-04, and IEC\/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA per standard CSA\/CAN C22.2 No. 61010.1-04; TUV per standard IEC\/EN 61010-1 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFour AA batteries (NEDA 15A or IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eInsulation test use:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance measurements:\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOperating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m CAT IV 600 V, 3000 m CAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating (storage)\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-range capability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e110% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded accessories\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1507 Insulation Tester\u003c\/li\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eTest probes\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1507_and_1503_Spec.pdf?1803\" target=\"_blank\" title=\"Fluke 1507 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1507 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2018-03-07T15:10:22-07:00","created_at":"2018-03-07T15:13:21-07:00","vendor":"Fluke","type":"Insulation Testers","tags":[],"price":116551,"price_min":116551,"price_max":116551,"available":true,"price_varies":false,"compare_at_price":84000,"compare_at_price_min":84000,"compare_at_price_max":84000,"compare_at_price_varies":false,"variants":[{"id":11043776004139,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-1507","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1507 Insulation Resistance Tester","public_title":null,"options":["Default Title"],"price":116551,"weight":2268,"compare_at_price":84000,"inventory_management":"shopify","barcode":"095969288675","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke1507-2.png?v=1520460804"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke1507-2.png?v=1520460804","options":["Title"],"media":[{"alt":null,"id":1476022861867,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1050,"width":1050,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke1507-2.png?v=1520460804"},"aspect_ratio":1.0,"height":1050,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke1507-2.png?v=1520460804","width":1050}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications.\u003c\/p\u003e\n\u003cp\u003eTake advantage of the 1507 full feature set to easily and quickly perform advanced insulation resistance testing. Its handy size and light weight make it easy to pack and use. Additional features, like the remote probe, save both time and money especially when performing repetitive tests. And its reasonable price and rugged reliability make it an excellent value.\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRugged, compact advanced insulation resistance tester for electrical contractors and industrial and commercial electricians\u003c\/li\u003e\n\u003cli\u003eAutomatically calculates Polarization Index and Dielectric Absorption Ratio\u003c\/li\u003e\n\u003cli\u003eMakes repetitive tests simple and easy with a Compare (Pass\/Fail) function \u003c\/li\u003e\n\u003cli\u003eOffers multiple insulation test voltages: 50 V, 100 V, 250 V, 500 V, and  1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePerforms insulation tests from 0.01 MΩ to 2.0 GΩ\u003c\/li\u003e\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage from 0.1 V to 600 V and resistance from 0.01 Ω to 20.00 kΩ\u003c\/li\u003e\n\u003cli\u003eProvides lo-ohms earth-bond continuity (200 mA)\u003c\/li\u003e\n\u003cli\u003eSimplifies repetitive or hard-to-reach testing with the remote test probe\u003c\/li\u003e\n\u003cli\u003eSaves battery power with auto power off\u003c\/li\u003e\n\u003cli\u003ePresents results on a large, backlit display\u003c\/li\u003e\n\u003cli\u003eFeatures CAT IV 600 V overvoltage category rating\u003c\/li\u003e\n\u003cli\u003eComes with remote probe, test leads, test probes, alligator clips and one-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC\/DC Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 Hz to 400 Hz ± (% of Rdg + Digits)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 MΩ (nominal), \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio (1 kΩ unbalanced):\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 60 dB at DC, 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEarth Bond Resistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e20.00 Ω\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200.0 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003e1.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit test voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 4.0 V, \u0026lt; 8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 200.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInsulation Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+ 20%, - 0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto discharge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDischarge time \u0026lt; 0.5 second for C = 1 µF or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive circuit indicator\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInhibit test if terminal voltage \u0026gt; 30 V prior to initialization of test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOperable with up to 1 µF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eMeasure accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e50 V\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage applied to any terminal:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V AC rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.05 x (specified accuracy) per °C for temperatures \u0026lt; 18°C or \u0026gt; 28°C (\u0026lt; 64°F or \u0026gt; 82°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRelative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 95% @ 10°C to 30°C (50°F to 86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 75% @ 30°C to 40°C (86°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 40% @ 40°C to 55°C (104°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIn an RF field of 3 V\/M, accuracy = specified accuracy (EN 61326-1:1997)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eComplies with ANSI\/ISA 82.02.01 (61010-1) 2004, CAN\/CSA-C22.2 NO. 61010-1-04, and IEC\/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA per standard CSA\/CAN C22.2 No. 61010.1-04; TUV per standard IEC\/EN 61010-1 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFour AA batteries (NEDA 15A or IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eInsulation test use:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance measurements:\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOperating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m CAT IV 600 V, 3000 m CAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating (storage)\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-range capability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e110% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded accessories\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1507 Insulation Tester\u003c\/li\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eTest probes\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1507_and_1503_Spec.pdf?1803\" target=\"_blank\" title=\"Fluke 1507 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1507 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e"}
Fluke 1507 Insulation Resistance Tester

Fluke 1507 Insulation Resistance Tester

$1,165.51 CAD

The Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications. Take advantage of the 1507 full feature set to easily and quickly perform advanced ins...


More Info
Fluke 1550C 5kV Digital Insulation Tester

Insulation Testers

From $8,567.99 CAD
{"id":1038411464747,"title":"Fluke 1550C 5kV Digital Insulation Tester","handle":"fluke-1550c-5kv-insulation-resistance-tester","description":"\u003cp\u003e\u003cspan\u003eThe Fluke 1550C performs digital insulation testing up to 5 kV, and makes the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTrust the best name in the business for all your insulation testing with the Fluke 1550C. With advanced testing methods, reporting, and best-in-class performance, this is the number one insulation tester in the industry. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage (DC)\u003c\/td\u003e\n\u003ctd\u003eRange (DC)\u003c\/td\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e250 kΩ to 5 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 GΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 50 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e500 kΩ to 10 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 GΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 100 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e1 MΩ to 20 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20 GΩ to 200 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 200 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e50 GΩ to 500 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 500 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 MΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e100 GΩ to 1 TΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 1 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLeakage Current Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 nA to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (5 % + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCapacitance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 uF to 15.00°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (15 % rdg + 0.03°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest cables with alligator clips (red, black, green)\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC power cord\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eEnglish manual\u003c\/li\u003e\n\u003cli\u003eUser's manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eQuick reference card\u003c\/li\u003e\n\u003cli\u003eSoftware license agreement\u003c\/li\u003e\n\u003cli\u003eRegistration card\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms installation guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR cable installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1550-1555_Spec.pdf?1595\" target=\"_blank\" title=\"Fluke 1550C Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1550C Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-02-21T14:50:18-07:00","created_at":"2018-02-21T14:54:58-07:00","vendor":"Fluke","type":"Insulation Testers","tags":[],"price":856799,"price_min":856799,"price_max":943295,"available":true,"price_varies":true,"compare_at_price":653300,"compare_at_price_min":653300,"compare_at_price_max":653300,"compare_at_price_varies":false,"variants":[{"id":10706613174315,"title":"1550C","option1":"1550C","option2":null,"option3":null,"sku":"FLU-1550C","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1550C 5kV Digital Insulation Tester - 1550C","public_title":"1550C","options":["1550C"],"price":856799,"weight":6804,"compare_at_price":653300,"inventory_management":"shopify","barcode":"095969550918","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16793563627563,"title":"1550C\/KIT","option1":"1550C\/KIT","option2":null,"option3":null,"sku":"FLU-1550C\/KIT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1550C 5kV Digital Insulation Tester - 1550C\/KIT","public_title":"1550C\/KIT","options":["1550C\/KIT"],"price":943295,"weight":6804,"compare_at_price":653300,"inventory_management":"shopify","barcode":"095969550987","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16793569198123,"title":"1550C FC","option1":"1550C FC","option2":null,"option3":null,"sku":"FLU-1550C FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1550C 5kV Digital Insulation Tester - 1550C FC","public_title":"1550C FC","options":["1550C FC"],"price":872167,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969868785","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C.jpg?v=1562783826","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C_BHD.jpg?v=1562783826","\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-1550c-01b-s.jpg?v=1562783826"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C.jpg?v=1562783826","options":["Model"],"media":[{"alt":null,"id":2797304807467,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C.jpg?v=1562783826"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C.jpg?v=1562783826","width":800},{"alt":null,"id":1417403858987,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C_BHD.jpg?v=1562783826"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C_BHD.jpg?v=1562783826","width":1200},{"alt":null,"id":1417412182059,"position":3,"preview_image":{"aspect_ratio":1.493,"height":402,"width":600,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-1550c-01b-s.jpg?v=1562783826"},"aspect_ratio":1.493,"height":402,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-1550c-01b-s.jpg?v=1562783826","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Fluke 1550C performs digital insulation testing up to 5 kV, and makes the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTrust the best name in the business for all your insulation testing with the Fluke 1550C. With advanced testing methods, reporting, and best-in-class performance, this is the number one insulation tester in the industry. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage (DC)\u003c\/td\u003e\n\u003ctd\u003eRange (DC)\u003c\/td\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e250 kΩ to 5 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 GΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 50 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e500 kΩ to 10 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 GΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 100 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e1 MΩ to 20 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20 GΩ to 200 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 200 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e50 GΩ to 500 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 500 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 MΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e100 GΩ to 1 TΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 1 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLeakage Current Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 nA to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (5 % + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCapacitance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 uF to 15.00°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (15 % rdg + 0.03°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest cables with alligator clips (red, black, green)\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC power cord\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eEnglish manual\u003c\/li\u003e\n\u003cli\u003eUser's manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eQuick reference card\u003c\/li\u003e\n\u003cli\u003eSoftware license agreement\u003c\/li\u003e\n\u003cli\u003eRegistration card\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms installation guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR cable installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1550-1555_Spec.pdf?1595\" target=\"_blank\" title=\"Fluke 1550C Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1550C Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 1550C 5kV Digital Insulation Tester

Fluke 1550C 5kV Digital Insulation Tester

$8,721.67 CAD

The Fluke 1550C performs digital insulation testing up to 5 kV, and makes the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur.  Trust the best name in the business for all your insulation testing with the Fluke 1550C. With advanced testing methods, reporting, and ...


More Info