{ "id":1078687563819, "title":"Fluke 1750 Three-Phase Power Quality Recorder","handle":"fluke-1750-three-phase-power-quality-recorder", "description":"\u003cp\u003e\u003cspan\u003eSetting up a power quality analyzer to capture detailed power quality data has never been easier that it is with the Fluke 1750. The only things you need to know are the system voltage, frequency and the power configuration (delta or wye). The analyzer then captures the most important data for up to 30 days without losing the most important details. These power meters automatically record every power quality parameter and event, on every cycle – all the time. Once the data is captured download via Ethernet or directly to 2GB SD card (without the need of any other device). The Fluke 1750 features a wireless front panel for viewing measurements, data and setting up, implemented via a tablet computer using Bluetooth communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLong-term analysis: Uncover hard-to-find or intermittent issues; monitor critical equipment, capturing power quality events to correlate with equipment malfunction\u003c\/li\u003e\n\u003cli\u003ePower quality surveys: Quantify power quality throughout a facility, documenting results with professional reports\u003c\/li\u003e\n\u003cli\u003eQuality of service compliance: Validate incoming power quality at the service entrance\u003c\/li\u003e\n\u003cli\u003eEquipment Installation\/Commissioning: Benchmark: power system prior to install to insure quality of service\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Term Analysis\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Uncover hard-to-find or intermittent issues.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Studies\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Verify the available electrical system capacity before adding loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAllows you to apply thresholds after data is collected, with Fluke Power Analyze Software–no need to worry about missed information due to incorrect setups\u003c\/li\u003e\n\u003cli\u003eCaptures every measurement, on every channel, every time with cross-channel, and current triggering capture\u003c\/li\u003e\n\u003cli\u003eAllows you to easily analyze data and generate reports in intuitive PC software with automated EN50160 reporting and compliance\u003c\/li\u003e\n\u003cli\u003eAutomatically creates standard or customized reports with Auto Report and exports reports to almost any format including RTF (Rich Text Format) for editing in Microsoft Word.\u003c\/li\u003e\n\u003cli\u003eSets up in minutes with self-identifying current probes and single-lead voltage connections\u003c\/li\u003e\n\u003cli\u003eAllows you to swap channels internally with the wireless tablet or PC when connections are not correct. No need to reconnect wires\u003c\/li\u003e\n\u003cli\u003eMeasures every parameter voltage and current on three phases, neutral, and ground\u003c\/li\u003e\n\u003cli\u003eOffers 5 MHz, 8000 Vpk waveform capture to provide a detailed picture of even the shortest events\u003c\/li\u003e\n\u003cli\u003eQuickly retrieves data with included SD memory card or via the 100BaseT high-speed Ethernet connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eTechnical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"11\"\u003ePower quality measurement standards\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eConformance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 61999-1-4 Class 1, IEC 61000-4-30 Class A, S or B depending on measurement function, IEEE519, IEEE1159, IEEE1459 and EN50160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock\/calendar\u003c\/td\u003e\n\u003ctd\u003eLeap years, 24-hour clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal-time clock accuracy\u003c\/td\u003e\n\u003ctd\u003eNot more than ±1 s\/day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal memory capacity for data\u003c\/td\u003e\n\u003ctd\u003eAt least 2 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum recording period\u003c\/td\u003e\n\u003ctd\u003eAt least 31 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement time control\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd\u003eLimited only by the size of the internal memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower requirements\u003c\/td\u003e\n\u003ctd\u003e100 to 240 V rms ±10%, 47-63 Hz, 40 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating time during interruptions (internal UPS operation)\u003c\/td\u003e\n\u003ctd\u003e5 minutes per interruption, 60 minutes total operating time without recharging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e215 x 310 x 35 mm (8.5 x 12.2 x 3.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass (weight)\u003c\/td\u003e\n\u003ctd\u003e6.3 kg (14 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"7\"\u003eInput\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement types\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eOne Phase Plus Neutral, One Phase IT No Neutral, One Phase Split Phase, Three Phase Wye, Three Phase Delta, Three Phase IT, Three Phase High Leg, Three Phase Open Leg, 2 Element Delta, 21\/2 Element Wye\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eInput channels\u003c\/td\u003e\n\u003ctd\u003eVoltage: 4 channels, AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eCurrent: 5 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVoltage channels\u003c\/td\u003e\n\u003ctd\u003eInput resistance: 2 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eInput capacitance: \u0026lt; 20 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent input characteristics\u003c\/td\u003e\n\u003ctd\u003e2 V rms = full scale, 1 MΩ Input Impedance for ferro CTs, low impedance for Flexi-CTs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd\u003eSimultaneous digital sampling of voltage and current. Digital PLL synchronized sampling, internal frequency reference used during voltage drops.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eSynchronization and sampling\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003ePLL-synchronization source\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eThe PLL synchronizes to the A-N voltage for wye power types, and to the A-B voltage for delta power types. All listed power types can be characterized as either wye or delta.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLL lock range\u003c\/td\u003e\n\u003ctd\u003e42.5 to 69 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling frequency\u003c\/td\u003e\n\u003ctd\u003eVoltage and current: 256 samples\/cycle Inter-harmonics per IEC 61000-4-7: 2 560 points\/10 cycles (50 Hz), 3072 points\/12 cycles (60 Hz) Transient Voltage: 5 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D resolution\u003c\/td\u003e\n\u003ctd\u003eVoltage and current: 24 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eTransient voltage: 14 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eVoltage and current measurements\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cb\u003eVoltage measurement range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eAC voltage: 1000 V rms ±10% over range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDC voltage: ±1000 V + 10% over range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage crest factor\u003c\/td\u003e\n\u003ctd\u003e3 or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent measurement range\u003c\/td\u003e\n\u003ctd\u003eDepends on current probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent crest factor\u003c\/td\u003e\n\u003ctd\u003e4 or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eRMS voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue rms calculated continuously: every cycle, every 1\/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by IEC 61000-4-30.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMeasurement uncertainty\u003c\/td\u003e\n\u003ctd\u003eAC: ±0.2% reading ±0.1% full scale, above 50 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eDC: ±0.5% reading ±0.2% full scale, above 50 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRMS current\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue RMS calculated continuously: every cycle, every 1\/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eTransient voltage (impulse)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eWaveshape sampling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale\u003c\/td\u003e\n\u003ctd\u003e8000 V pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample resolution\u003c\/td\u003e\n\u003ctd\u003e200 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement uncertainty\u003c\/td\u003e\n\u003ctd\u003e±5% reading ±20 V (test parameters: 1000 V DC, 1000 V rms, 100 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage swell (rms swell)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue RMS (one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplayed data\u003c\/td\u003e\n\u003ctd\u003eAmplitude and duration of swell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eSame as rms voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage dip (rms sag)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue RMS (one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplayed data\u003c\/td\u003e\n\u003ctd\u003eAmplitude and duration of dip or interruption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eSame as rms voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage dropout (interruption)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eSame as voltage dip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eLAN interface\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eConnector\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed and type\u003c\/td\u003e\n\u003ctd\u003e10\/100 Base-T, auto MDIX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications protocol\u003c\/td\u003e\n\u003ctd\u003eTCP\/IP over Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eWireless controller interface\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eConnection\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ewireless (2.4 GHz radio)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed\u003c\/td\u003e\n\u003ctd\u003eup to 700 kbit\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications protocol\u003c\/td\u003e\n\u003ctd\u003eBluetooth SPP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePower Measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower, battery life\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue RMS calculated continuously: every cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e42.5 to 69 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement source\u003c\/td\u003e\n\u003ctd\u003eSame as PLL synchronization source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd\u003e±10 mHz (10 to 110% of range, with sine wave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003ePower factor\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.000 to 1.000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 digit from the calculation of each measured value (±3 digits for total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDisplacement power factor\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement method\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eCalculated from the phase difference between voltage fundamental and current fundamental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e- 1.000 (leading) to + 1.000 (lagging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% reading ±2% full scale ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage unbalance and phase sequence\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasurement method\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive sequence voltage divided by negative sequence voltage, per IEC 61000-4-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eHarmonic voltage and current\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAnalysis window\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003erectangular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalysis order\u003c\/td\u003e\n\u003ctd\u003e1st to 50th order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd\u003eVoltage \/ Current: 1st to 20th orders: ±0.5% reading ±0.2% full scale, 21st to 50th orders: ±1% reading ±0.3% full scale (current sensor accuracy must be included for current and power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement method\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-4-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eInter-harmonic voltage and current (intermediate harmonics)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAnalysis window\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003erectangular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalysis orders\u003c\/td\u003e\n\u003ctd\u003e1.5 to 49.5th order\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement method\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-4-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFlicker\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cb\u003eMeasurement method\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 61000-4-15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003ePlt for 2 hours and Pst for 10 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0,1 to 5 (25) depending on voltage level, modulation and frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOperating environment\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoors or in covered area outdoors, up to 2,000 m altitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature and humidity\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C, 80% RH max, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature and humidity\u003c\/td\u003e\n\u003ctd\u003e0°C to 40°C, 80% RH max, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eMaximum rated working voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eVoltage terminals\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1100 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage durability\u003c\/td\u003e\n\u003ctd\u003e5550 V rms AC for 1 minute, between voltage input terminals, voltage input terminals and current probes, and voltage input terminals and case (50\/60 Hz, 1 mA sense current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure protection\u003c\/td\u003e\n\u003ctd\u003eIP30 (per EN 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eStandards\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cb\u003eEMC\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61326-1:1997+A1:1998 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN 61000-3-2:1995+A1:1998+A2:1998\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN 61000-3-3:1995\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cb\u003eSafety\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1 2 nd Edition; 2 000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eVoltage input unit: Contamination Level 2 , Overvoltage Category 1000 V CAT III, 600 V CAT IV (anticipated overvoltage: 8000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003eFluke 1750\/ET Three-Phase Power Quality Recorder\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1750 acquisition unit\u003c\/li\u003e\n\u003cli\u003e1750 handheld tablet\u003c\/li\u003e\n\u003cli\u003e4 x 400A current probes (3140)\u003c\/li\u003e\n\u003cli\u003e5 Test leads and clips\u003c\/li\u003e\n\u003cli\u003e2GB SD Memory card (larger cards not compatible)\u003c\/li\u003e\n\u003cli\u003eFluke Power View and Fluke Power Analyze software\u003c\/li\u003e\n\u003cli\u003ePower cord with international plug set\u003c\/li\u003e\n\u003cli\u003eEthernet cable\u003c\/li\u003e\n\u003cli\u003eColor localization set\u003c\/li\u003e\n\u003cli\u003ePrinted Getting Started manual\u003c\/li\u003e\n\u003cli\u003eProduct CD with software and user manual PDF\u003c\/li\u003e\n\u003cli\u003eCS 1750\/1760 Rugged transit softcase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003eFluke 1750-TF Three-Phase Power Quality Recorder\u003cbr\u003e4 – 1,000A 3210-PR- TF iFlex flexible current probe\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1750 acquisition unit\u003c\/li\u003e\n\u003cli\u003e1750 handheld tablet\u003c\/li\u003e\n\u003cli\u003e5 Test leads and clips\u003c\/li\u003e\n\u003cli\u003e2GB SD Memory card (larger cards not compatible)\u003c\/li\u003e\n\u003cli\u003eFluke Power View and Fluke Power Analyze software\u003c\/li\u003e\n\u003cli\u003ePower cord with international plug set\u003c\/li\u003e\n\u003cli\u003eEthernet cable\u003c\/li\u003e\n\u003cli\u003eColor localization set\u003c\/li\u003e\n\u003cli\u003ePrinted Getting Started manual\u003c\/li\u003e\n\u003cli\u003eProduct CD with software and user manual PDF\u003c\/li\u003e\n\u003cli\u003eCS 1750\/1760 Rugged transit softcase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1750_Energy_Recorder_Spec.pdf?1811\" target=\"_blank\" title=\"Fluke 1750 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1750 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-03-08T10:09:57", "created_at":"2018-03-08T10:16:53", "vendor":"Fluke", "type":"Power Quality", "tags":[], "price":2100000, "price_min":2100000, "price_max":2184000, "price_varies":true, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[11060026441771,30267413200939], "variants":[{ "id":11060026441771, "product_id":1078687563819, "product_handle":"fluke-1750-three-phase-power-quality-recorder", "title":"FLU-1750\/ET", "option1":"FLU-1750\/ET", "option2":null, "option3":null, "sku":"FLU-1750\/ET", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 1750 Three-Phase Power Quality Recorder - FLU-1750\/ET", "options":["FLU-1750\/ET"], "price":2100000, "weight":15000, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":""},{ "id":30267413200939, "product_id":1078687563819, "product_handle":"fluke-1750-three-phase-power-quality-recorder", "title":"FLU-1750-TF\/ET", "option1":"FLU-1750-TF\/ET", "option2":null, "option3":null, "sku":"FLU-1750-TF\/ET", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 1750 Three-Phase Power Quality Recorder - FLU-1750-TF\/ET", "options":["FLU-1750-TF\/ET"], "price":2184000, "weight":15000, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":""}], "available":true,"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/71cSyjGnC1L._SL1500.jpg?v=1569598398","\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke_1750.jpg?v=1569598398"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/71cSyjGnC1L._SL1500.jpg?v=1569598398", "options":["Model"], "url":"\/products\/fluke-1750-three-phase-power-quality-recorder"}

Fluke 1750 Three-Phase Power Quality Recorder

Product Description

Setting up a power quality analyzer to capture detailed power quality data has never been easier that it is with the Fluke 1750. The only things you need to know are the system voltage, frequency and the power configuration (delta or wye). The analyzer then captures the most important data for up to 30 days without losing the most important details. These power meters automatically record every power quality parameter and event, on every cycle – all the time. Once the data is captured download via Ethernet or directly to 2GB SD card (without the need of any other device). The Fluke 1750 features a wireless front panel for viewing measurements, data and setting up, implemented via a tablet computer using Bluetooth communication.

Sku: FLU-1750/ET
Vendor: Fluke
On Back-Order
$21,840.00 CAD

Common Applications

  • Long-term analysis: Uncover hard-to-find or intermittent issues; monitor critical equipment, capturing power quality events to correlate with equipment malfunction
  • Power quality surveys: Quantify power quality throughout a facility, documenting results with professional reports
  • Quality of service compliance: Validate incoming power quality at the service entrance
  • Equipment Installation/Commissioning: Benchmark: power system prior to install to insure quality of service
    • Long-Term Analysis – Uncover hard-to-find or intermittent issues.
    • Load Studies – Verify the available electrical system capacity before adding loads.

Other useful features:

  • Allows you to apply thresholds after data is collected, with Fluke Power Analyze Software–no need to worry about missed information due to incorrect setups
  • Captures every measurement, on every channel, every time with cross-channel, and current triggering capture
  • Allows you to easily analyze data and generate reports in intuitive PC software with automated EN50160 reporting and compliance
  • Automatically creates standard or customized reports with Auto Report and exports reports to almost any format including RTF (Rich Text Format) for editing in Microsoft Word.
  • Sets up in minutes with self-identifying current probes and single-lead voltage connections
  • Allows you to swap channels internally with the wireless tablet or PC when connections are not correct. No need to reconnect wires
  • Measures every parameter voltage and current on three phases, neutral, and ground
  • Offers 5 MHz, 8000 Vpk waveform capture to provide a detailed picture of even the shortest events
  • Quickly retrieves data with included SD memory card or via the 100BaseT high-speed Ethernet connection.
Technical Specifications
Power quality measurement standards Conformance IEC 61999-1-4 Class 1, IEC 61000-4-30 Class A, S or B depending on measurement function, IEEE519, IEEE1159, IEEE1459 and EN50160
Clock/calendar Leap years, 24-hour clock
Real-time clock accuracy Not more than ±1 s/day
Internal memory capacity for data At least 2 GB
Maximum recording period At least 31 days
Measurement time control Automatic
Maximum number of events Limited only by the size of the internal memory
Power requirements 100 to 240 V rms ±10%, 47-63 Hz, 40 W
Operating time during interruptions (internal UPS operation) 5 minutes per interruption, 60 minutes total operating time without recharging
Dimensions 215 x 310 x 35 mm (8.5 x 12.2 x 3.5 in)
Mass (weight) 6.3 kg (14 lb)
Input Measurement types One Phase Plus Neutral, One Phase IT No Neutral, One Phase Split Phase, Three Phase Wye, Three Phase Delta, Three Phase IT, Three Phase High Leg, Three Phase Open Leg, 2 Element Delta, 21/2 Element Wye
Input channels Voltage: 4 channels, AC/DC
Current: 5 channels
Voltage channels Input resistance: 2 MΩ
Input capacitance: < 20 pF
Current input characteristics 2 V rms = full scale, 1 MΩ Input Impedance for ferro CTs, low impedance for Flexi-CTs
Measuring method Simultaneous digital sampling of voltage and current. Digital PLL synchronized sampling, internal frequency reference used during voltage drops.
Synchronization and sampling PLL-synchronization source The PLL synchronizes to the A-N voltage for wye power types, and to the A-B voltage for delta power types. All listed power types can be characterized as either wye or delta.
PLL lock range 42.5 to 69 Hz
Sampling frequency Voltage and current: 256 samples/cycle Inter-harmonics per IEC 61000-4-7: 2 560 points/10 cycles (50 Hz), 3072 points/12 cycles (60 Hz) Transient Voltage: 5 MHz
A/D resolution Voltage and current: 24 bits
Transient voltage: 14 bits
Voltage and current measurements Voltage measurement range AC voltage: 1000 V rms ±10% over range
DC voltage: ±1000 V + 10% over range
Voltage crest factor 3 or less
Current measurement range Depends on current probe used
Current crest factor 4 or less
RMS voltage Measurement type True rms calculated continuously: every cycle, every 1/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by IEC 61000-4-30.
Measurement uncertainty AC: ±0.2% reading ±0.1% full scale, above 50 V rms
DC: ±0.5% reading ±0.2% full scale, above 50 V dc
RMS current Measurement type True RMS calculated continuously: every cycle, every 1/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards
Transient voltage (impulse) Measurement type Waveshape sampling
Full scale 8000 V pk
Sample resolution 200 nS
Measurement uncertainty ±5% reading ±20 V (test parameters: 1000 V DC, 1000 V rms, 100 kHz)
Voltage swell (rms swell) Measurement type True RMS (one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines)
Displayed data Amplitude and duration of swell
Measurement Same as rms voltage
Voltage dip (rms sag) Measurement type True RMS (one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines)
Displayed data Amplitude and duration of dip or interruption
Measurement Same as rms voltage
Voltage dropout (interruption) Measurement type Same as voltage dip
LAN interface Connector RJ-45
Speed and type 10/100 Base-T, auto MDIX
Communications protocol TCP/IP over Ethernet
Wireless controller interface Connection wireless (2.4 GHz radio)
Speed up to 700 kbit/second
Communications protocol Bluetooth SPP
Power Measurements
Power, battery life Measurement type True RMS calculated continuously: every cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards
Frequency Measurement range 42.5 to 69 Hz
Measurement source Same as PLL synchronization source
Measurement accuracy ±10 mHz (10 to 110% of range, with sine wave)
Power factor Measurement range 0.000 to 1.000
Measurement accuracy ±1 digit from the calculation of each measured value (±3 digits for total)
Displacement power factor Measurement method Calculated from the phase difference between voltage fundamental and current fundamental
Measurement range - 1.000 (leading) to + 1.000 (lagging)
Measurement accuracy ±0.5% reading ±2% full scale ±1 digit
Voltage unbalance and phase sequence Measurement method Positive sequence voltage divided by negative sequence voltage, per IEC 61000-4-30
Harmonic voltage and current Analysis window rectangular
Analysis order 1st to 50th order
Measurement accuracy Voltage / Current: 1st to 20th orders: ±0.5% reading ±0.2% full scale, 21st to 50th orders: ±1% reading ±0.3% full scale (current sensor accuracy must be included for current and power)
Measurement method IEC 61000-4-7
Inter-harmonic voltage and current (intermediate harmonics) Analysis window rectangular
Analysis orders 1.5 to 49.5th order
Measurement method IEC 61000-4-7
Flicker Measurement method IEC 61000-4-15
Plt for 2 hours and Pst for 10 minutes
Measuring range 0,1 to 5 (25) depending on voltage level, modulation and frequency
Environmental Specifications
Environmental Operating environment Indoors or in covered area outdoors, up to 2,000 m altitude
Storage temperature and humidity -20°C to 50°C, 80% RH max, non-condensing
Operating temperature and humidity 0°C to 40°C, 80% RH max, non-condensing
Maximum rated working voltage Voltage terminals 1100 V rms
Voltage durability 5550 V rms AC for 1 minute, between voltage input terminals, voltage input terminals and current probes, and voltage input terminals and case (50/60 Hz, 1 mA sense current)
Enclosure protection IP30 (per EN 60529)
Standards EMC EN 61326-1:1997+A1:1998 Class A
EN 61000-3-2:1995+A1:1998+A2:1998
EN 61000-3-3:1995
Safety EN 61010-1 2 nd Edition; 2 000
Voltage input unit: Contamination Level 2 , Overvoltage Category 1000 V CAT III, 600 V CAT IV (anticipated overvoltage: 8000 V)


Fluke 1750/ET Three-Phase Power Quality Recorder

Includes:

  • 1750 acquisition unit
  • 1750 handheld tablet
  • 4 x 400A current probes (3140)
  • 5 Test leads and clips
  • 2GB SD Memory card (larger cards not compatible)
  • Fluke Power View and Fluke Power Analyze software
  • Power cord with international plug set
  • Ethernet cable
  • Color localization set
  • Printed Getting Started manual
  • Product CD with software and user manual PDF
  • CS 1750/1760 Rugged transit softcase
Fluke 1750-TF Three-Phase Power Quality Recorder
4 – 1,000A 3210-PR- TF iFlex flexible current probe

Includes:

  • 1750 acquisition unit
  • 1750 handheld tablet
  • 5 Test leads and clips
  • 2GB SD Memory card (larger cards not compatible)
  • Fluke Power View and Fluke Power Analyze software
  • Power cord with international plug set
  • Ethernet cable
  • Color localization set
  • Printed Getting Started manual
  • Product CD with software and user manual PDF
  • CS 1750/1760 Rugged transit softcase