{ "id":1079388504107, "title":"Fluke 414D\/62 MAX+ Laser Distance Meter\/Infrared Thermometer Combo Kit","handle":"fluke-414d-62-max-laser-distance-meter-infrared-thermometer-combo-kit", "description":"\u003cp\u003e\u003cspan\u003eThe most rugged Fluke 62 MAX+ IR thermometer teamed with the easy to use 414D Laser Distance Meter has everything you need to configure layout and to troubleshoot electrical\/hvac problems quickly. Use the IR thermometer to test for overheating in electrical devices and HVAC components, and use the laser distance meter to determine distance, area, and volume for space configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cp\u003e\u003cstrong\u003eThe 414D reduces errors, saves time and money\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe most advanced laser technology for distance measurement\u003c\/li\u003e\n\u003cli\u003eMeasures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in)\u003c\/li\u003e\n\u003cli\u003eQuick calculation of area (square feet\/meters) and volume \u003c\/li\u003e\n\u003cli\u003ePythagoras function indirectly measures height via two other measurements\u003c\/li\u003e\n\u003cli\u003eStores up to five measurement results\u003c\/li\u003e\n\u003cli\u003eBattery life of 3000 measurements with automatic shut-off feature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 62 MAX+. Small in size. Big on toughness\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDust and water-resistant: IP54 rated\u003c\/li\u003e\n\u003cli\u003eRugged: 3-meter (9.8-foot) drop tested\u003c\/li\u003e\n\u003cli\u003eErgonomically designed: Completely redesigned for a more natural hand fit\u003c\/li\u003e\n\u003cli\u003eDistance to spot: 12:1\u003c\/li\u003e\n\u003cli\u003eDual lasers: Identifies area to be measured\u003c\/li\u003e\n\u003cli\u003eLarge, backlit display: Makes data easier to read, even in dark areas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 414D Laser Distance Meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Measuring Tolerance ¹\u003c\/td\u003e\n\u003ctd\u003e±2.0 mm ³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Measuring Tolerance ²\u003c\/td\u003e\n\u003ctd\u003e±3.0 mm ³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange At Leica Target Plate GZM26\u003c\/td\u003e\n\u003ctd\u003e50 m \/ 165 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Range ¹\u003c\/td\u003e\n\u003ctd\u003e40 m \/ 130 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange At Unfavorable Condition\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e35 m \/ 115 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmallest Unit Displayed\u003c\/td\u003e\n\u003ctd\u003e1 mm \/ 1\/16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eØ Laser Point At Distances\u003c\/td\u003e\n\u003ctd\u003e6 \/ 30 \/ 60 mm\u003cbr\u003e(10 \/ 50 \/ 100 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTilt Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Tolerance To Laser Beam\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Tolerance To Housing\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eGeneral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser Class\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser Type\u003c\/td\u003e\n\u003ctd\u003e635 nm, \u0026lt; 1 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Laser Off\u003c\/td\u003e\n\u003ctd\u003eAfter 90 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd\u003eAfter 180 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life (2 x AAA) 1.5 V NEDA 24A\/IEC LR03\u003c\/td\u003e\n\u003ctd\u003eUp to 3,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x D)\u003c\/td\u003e\n\u003ctd\u003e116 x 53 x 33 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with batteries)\u003c\/td\u003e\n\u003ctd\u003e113 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature Range:\u003cbr\u003eStorage Operation\u003c\/td\u003e\n\u003ctd\u003e-25 °C to +70 °C (-13 °F to +158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 °C to +40 °C (32 °F to +104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Cycle\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Altitude\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Relative Humidity\u003c\/td\u003e\n\u003ctd\u003e85% at 20 °F to 120 °F (-7 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC Standard No. 61010-1:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEN60825-1:2007 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 55022:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEN 61000-4-3:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEN 61000-4-8:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25 °C.\u003cbr\u003e2. Applies for 10 to 500% target reflectivity, high background illumination, -10 °C to +50 °C.\u003cbr\u003e3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm\/m between 10 m to 30 m and to 0.15 mm\/m for distances above 30 m.\u003cbr\u003e4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux.\u003cbr\u003e5. After user calibration. Additional angle related deviation of ±0.01 ° per degree up to ±45 ° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1 °\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 62 MAX+ Infrared Thermometer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-30 °C to 650 °C (-22 °F to 1202 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±1.0 °C or ±1.0% of reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e-10 °C to 0 °C: ±2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e-30 °C to -10 °C: ±3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResponse Time (95%)\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFluke 62 MAX+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 300 ms (95% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral response\u003c\/td\u003e\n\u003ctd\u003e8 to 14 microns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissivity\u003c\/td\u003e\n\u003ctd\u003e0.10 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12:1 (calculated at 90% energy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 °C (0.2 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability Of Readings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.5% of reading or \u0026lt; ±0.5 °C (1 °F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAA battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 hours with laser and backlight on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003ePhysical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e255 g (8.99 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 °C to 50 °C (32 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature (Without Battery)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20 °C to 60 °C (-4 °F to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10% to 90% RH non-condensing at 30 °C (86 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12,000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 54 per IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop Test\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVibration And Shock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 68-2-6 2.5 g, 10 to 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eIEC 68-2-27, 50 g, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eEMC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61326-1:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eEN 61326-2:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eStandards And Agency Approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN\/IEC 61010-1: 2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser Safety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFDA and EN 60825-1 Class II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 414D Laser Distance Meter\u003c\/li\u003e\n\u003cli\u003eFluke 62 MAX+ IR Thermometer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_414D-419D-424D_Laser_Distance_Spec.PDF?1827\" target=\"_blank\" title=\"Fluke 414D Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 414D Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_62_MAX_and_62_MAX_data_sheet_080b77f5-baa8-45b6-ac5c-a0c1e1cc8fa2.pdf?1828\" target=\"_blank\" title=\"Fluke 62 Max+ Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 62 MAX+ Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-03-08T16:03:56", "created_at":"2018-03-08T16:06:42", "vendor":"Fluke", "type":"Infrared Thermometers", "tags":[], "price":36000, "price_min":36000, "price_max":36000, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[11068434939947], "variants":[{ "id":11068434939947, "product_id":1079388504107, "product_handle":"fluke-414d-62-max-laser-distance-meter-infrared-thermometer-combo-kit", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"FLU-414D\/62MAX+", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 414D\/62 MAX+ Laser Distance Meter\/Infrared Thermometer Combo Kit - Default Title", "options":["Default Title"], "price":36000, "weight":3629, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"0 95969 65923 9"}], "available":true,"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/F-414d-62maxplus_01a_c.jpg?v=1520550404","\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/61eJNVLsF-L._SL1500.jpg?v=1520550404"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/F-414d-62maxplus_01a_c.jpg?v=1520550404", "options":["Title"], "url":"\/products\/fluke-414d-62-max-laser-distance-meter-infrared-thermometer-combo-kit"}

Fluke 414D/62 MAX+ Laser Distance Meter/Infrared Thermometer Combo Kit

Product Description

The most rugged Fluke 62 MAX+ IR thermometer teamed with the easy to use 414D Laser Distance Meter has everything you need to configure layout and to troubleshoot electrical/hvac problems quickly. Use the IR thermometer to test for overheating in electrical devices and HVAC components, and use the laser distance meter to determine distance, area, and volume for space configuration.

Sku: FLU-414D/62MAX+
Vendor: Fluke
On Back-Order
$360.00 CAD

Key features

The 414D reduces errors, saves time and money

  • The most advanced laser technology for distance measurement
  • Measures up to 50 m (165 ft) with accuracy of 2 mm (0.08 in)
  • Quick calculation of area (square feet/meters) and volume 
  • Pythagoras function indirectly measures height via two other measurements
  • Stores up to five measurement results
  • Battery life of 3000 measurements with automatic shut-off feature

Fluke 62 MAX+. Small in size. Big on toughness

  • Dust and water-resistant: IP54 rated
  • Rugged: 3-meter (9.8-foot) drop tested
  • Ergonomically designed: Completely redesigned for a more natural hand fit
  • Distance to spot: 12:1
  • Dual lasers: Identifies area to be measured
  • Large, backlit display: Makes data easier to read, even in dark areas

Fluke 414D Laser Distance Meter

Distance Measurement
Typical Measuring Tolerance ¹ ±2.0 mm ³
Maximum Measuring Tolerance ² ±3.0 mm ³
Range At Leica Target Plate GZM26 50 m / 165 ft
Typical Range ¹ 40 m / 130 ft
Range At Unfavorable Condition 4 35 m / 115 ft
Smallest Unit Displayed 1 mm / 1/16 in
Ø Laser Point At Distances 6 / 30 / 60 mm
(10 / 50 / 100 m)
Tilt Measurement
Measuring Tolerance To Laser Beam 5 No
Measuring Tolerance To Housing 5 No
Range No
General
Laser Class 2
Laser Type 635 nm, < 1 mW
Protection Class IP40
Automatic Laser Off After 90 seconds
Automatic Power Off After 180 seconds
Battery Life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 Up to 3,000 measurements
Size (L x W x D) 116 x 53 x 33 mm
Weight (with batteries) 113 g
Temperature Range:
Storage Operation
-25 °C to +70 °C (-13 °F to +158 °F)
0 °C to +40 °C (32 °F to +104 °F)
Calibration Cycle Not applicable
Maximum Altitude 3000 m
Maximum Relative Humidity 85% at 20 °F to 120 °F (-7 °C to 50 °C)
Safety IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II)
EMC EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010
1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25 °C.
2. Applies for 10 to 500% target reflectivity, high background illumination, -10 °C to +50 °C.
3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux.
5. After user calibration. Additional angle related deviation of ±0.01 ° per degree up to ±45 ° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1 °

Fluke 62 MAX+ Infrared Thermometer

Specifications
Temperature Range -30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%) Fluke 62 MAX+ < 300 ms (95% of reading)
Spectral response 8 to 14 microns
Emissivity 0.10 to 1.00
Optical Resolution 12:1 (calculated at 90% energy)
Display Resolution 0.1 °C (0.2 °F)
Repeatability Of Readings ±0.5% of reading or < ±0.5 °C (1 °F), whichever is greater
Power AA battery
Battery Life 8 hours with laser and backlight on
Physical Specifications
Weight 255 g (8.99 oz)
Size (L x W x D) 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature (Without Battery) -20 °C to 60 °C (-4 °F to 140 °F)
Operating Humidity 10% to 90% RH non-condensing at 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
IP Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration And Shock IEC 68-2-6 2.5 g, 10 to 200 Hz
IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006
EN 61326-2:2006
Standards And Agency Approval
Compliance EN/IEC 61010-1: 2001
Laser Safety FDA and EN 60825-1 Class II