{ "id":6715458650302, "title":"Industrial Scientific Ventis® Pro5 Personal Multi-Gas Monitor, 4 Gas, LEL - O2 - CO - H2S (VP5-K1231101111)","handle":"industrial-scientific-ventis®-pro5-personal-multi-gas-monitor-4-gas-lel-o2-co-h2s", "description":"\u003cp\u003eStop carrying multiple instruments to meet your gas detection needs. The Ventis™ Pro Series has you covered whether you need unique four-gas or expanded five-gas sensor options—all in the most configurable multi-gas monitors on the market.\u003c\/p\u003e\n\u003cp\u003eBuilt to raise the bar on worker safety, flexibility, and ease of use, the Ventis™ Pro Series offers unique four-gas and expanded five-gas sensor options. A panic button and man-down alarm alert users of emergency situations, alarm action messages provide clear safety instructions, and real-time user and site assignments track instruments and hazards. Backed by the industry’s only Guaranteed for Life™ warranty, the Ventis Pro Series offers the smallest and most configurable multi-gas monitors on the market. \u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFlexible sensor configurations detect up to five gases\u003c\/li\u003e\n\u003cli\u003eWith integral pump for confined spaces or without integral pump for personal protection\u003c\/li\u003e\n\u003cli\u003eCustom start-up messages, alarm action messages, and acknowledgeable gas alerts\u003c\/li\u003e\n\u003cli\u003eMan-down alarm and dedicated panic button\u003c\/li\u003e\n\u003cli\u003eUser and site tracking with iAssign™ Technology\u003c\/li\u003e\n\u003cli\u003eRugged IP68 dust and water rating and Guaranteed for Life™ warranty*\u003c\/li\u003e\n\u003cli\u003eCompatible with most Ventis™ MX4 accessories\u003c\/li\u003e\n\u003cli\u003eDock overdue and maintenance reminders\u003c\/li\u003e\n\u003cli\u003eiNet® and DSX docking station ready\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"font-size: 1.4em;\" class=\"table table-striped\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth width=\"20%\"\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDetail Description\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eTYPICAL RANGE OF GASES DETECTED\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eCATALYTIC BEAD\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eCombustible Gases\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-100% LEL in 1% increments\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eMethane (CH4)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5% of vol in 0.01% increments\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eELECTROCHEMICAL\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eAmmonia (NH3)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-500 ppm in 1 ppm increments\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eCarbon Monoxide (CO)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-2,000 ppm in 1 ppm increments\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eCarbon Monoxide (CO\/H2 low)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-1,000 ppm in 1 ppm increments\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eCarbon Monoxide\/Hydrogen Sulfide\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDUOTOX\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eCO\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-1,500 ppm in 1 ppm increments\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eH2S\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-500 ppm in 0.1 ppm increments\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eHydrogen Sulfide (H2S)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-500 ppm in 0.1 ppm increments\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eHydrogen Cyanide (HCN)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-30 ppm in 0.1 ppm increments\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eNitrogen Dioxide (NO2)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-150 ppm in 0.1 ppm increments\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eOxygen (O2)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-30% of vol in 0.1% increments\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eSulfur Dioxide (SO2)\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-150 ppm in 0.1 ppm increments\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cb\u003eINFRARED\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eCarbon Dioxide\/Hydrocarbons\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDual IR Cell\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eCO2\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5% vol in 0.01% increments\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eHC\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-100% LEL in 1% increments\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eCarbon Dioxide\/Methane\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDual IR Cell\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eCO2\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5% vol in 0.01% increments\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eCH4\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0-5% vol in 0.01% increments\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eCH4\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5-100% vol in 0.1% increments\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eGENERAL SPECIFICATIONS\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eKEYPAD\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTwo buttons for operation. Dedicated panic button.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eDATA LOG\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAt least 3 months at 10-second intervals\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eEVENT LOGGING\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e60 alarm events\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eINGRESS PROTECTION\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP68 (submersion at 1.5 meters for 1 hour)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eCASE MATERIAL\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003ePolycarbonate with protective rubber overmold\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eDIMENSIONS\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e104 x 58 x 36 mm (4.1 x 2.3 x 1.4 in) without pump\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e172 x 67 x 65 mm (6.8 x 2.6 x 2.6 in) with pump\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eWEIGHT\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e200 g (7.05 oz), typical without pump\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e390 g (13.76 oz), typical with pump\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eTEMPERATURE RANGE\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40 °C to 50 °C (-40 °F to 122 °F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eHUMIDITY RANGE\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e15%-95% non-condensing (continuous)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eDISPLAY\/READOUT\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBacklit liquid crystal display (LCD)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003ePOWER SOURCE\/RUN TIME\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRechargeable lithium-ion battery pack with LEL\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e(12 hours typical @ 20 ºC) – without pump\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRechargeable extended-range lithium-ion battery pack with LEL\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e(24 hours typical @ 20 ºC) – without pump\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e(18 hours typical @ 20 ºC) – with pump\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRechargeable lithium-ion battery pack with IR\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e(36 hours typical @ 20 ºC) – without pump\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRechargeable extended-range lithium-ion battery pack with IR\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e(72 hours typical @ 20 ºC) – without pump\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e(32 hours typical @ 20 ºC) – with pump\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eALARMS\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eFour visual alarm LEDs (two red, two blue); 95 decibel (dB) audible alarm at a distance of 10 cm (3.94 in); Vibration alarm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eSENSORS\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCombustible Gases\/Methane – Catalytic Bead. O2, CO, CO\/H2 low, H2S, HCN, NH3, NO2, SO2 – Electrochemical. CO2\/HC, CO\/CH4 - Infrared\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eCERTIFICATIONS\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eUL\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eClass I, Division 1, Groups A, B, C, and D, in the Temperature Class T4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eClass II, Division 1, Groups E, F, and G, in the Temperature Class T4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eClass I, Zone 0, AEx ia IIC, in the Temperature Class T4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eClass I, Zone 1, AEx d ia II C, in the Temperature Class T4, with IR sensor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eATEX\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEquipment Group and Category II 1G, Ex ia IIC, with the protection category Ga, in the Temperature Class T4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEquipment Group and Category II 2G, Ex d ia IIC, with the protection category Gb, in the Temperature Class T4, with IR sensor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eIECEx\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eClass I, Zone 0, Ex ia IIC, with the protection technique Ga, in the Temperature Class T4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eClass I, Zone 1, Ex d ia IIC, with the protection technique Gb, in the\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003cp\u003e\u003cb\u003eTemperature Class T4, with IR sensor\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eCSA\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eClass I, Division 1, Groups A, B, C, and D, in the Temperature Class T4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eClass I, Zone 1, Ex d ia IIC, in the Temperature Class T4\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eSUPPLIED WITH MONITOR\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eCalibration Cup (Ventis), Sample Tubing (Ventis with pump), Reference Guide\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eREFERENCE GUIDE LANGUAGE\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEnglish, French, Spanish, German\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cb\u003eWARRANTY\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGuaranteed for Life. Warranted for as long as the instrument is supported by Industrial Scientific Corporation (excludes sensors, batteries, and filters). O2, LEL, CO, and H2S sensors warranted for three years. All other sensors warranted for two years. Pumps and batteries are warranted for two years.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSupplied with Monitor:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCalibration Cup (Ventis)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSample Tubing (Ventis with pump)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReference Guide\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca title=\"Industrial Scientific Ventis® Pro5 Personal Multi-Gas Monitor\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Ventis_Pro5_Gas_Monitor_Spec_Sheet.pdf?v=1621350342\" target=\"_blank\"\u003eIndustrial Scientific Ventis® Pro5 Personal Multi-Gas Monitor\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2021-05-18T09:20:45", "created_at":"2021-05-18T09:20:44", "vendor":"Industrial Scientific", "type":"Gas Monitors", "tags":[], "price":176801, "price_min":176801, "price_max":176801, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[39771362689214], "variants":[{ "id":39771362689214, "product_id":6715458650302, "product_handle":"industrial-scientific-ventis®-pro5-personal-multi-gas-monitor-4-gas-lel-o2-co-h2s", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"IND-VP5-K1231101111", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Industrial Scientific Ventis® Pro5 Personal Multi-Gas Monitor, 4 Gas, LEL - O2 - CO - H2S (VP5-K1231101111) - Default Title", "options":["Default Title"], "price":176801, "weight":2268, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":""}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/VentisPro5Orange.jpg?v=1621351247"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/VentisPro5Orange.jpg?v=1621351247", "options":["Title"], "url":"\/products\/industrial-scientific-ventis%C2%AE-pro5-personal-multi-gas-monitor-4-gas-lel-o2-co-h2s"}

Industrial Scientific Ventis® Pro5 Personal Multi-Gas Monitor, 4 Gas, LEL - O2 - CO - H2S (VP5-K1231101111)

Product Description

Stop carrying multiple instruments to meet your gas detection needs. The Ventis™ Pro Series has you covered whether you need unique four-gas or expanded five-gas sensor options—all in the most configurable multi-gas monitors on the market.

Built to raise the bar on worker safety, flexibility, and ease of use, the Ventis™ Pro Series offers unique four-gas and expanded five-gas sensor options. A panic button and man-down alarm alert users of emergency situations, alarm action messages provide clear safety instructions, and real-time user and site assignments track instruments and hazards. Backed by the industry’s only Guaranteed for Life™ warranty, the Ventis Pro Series offers the smallest and most configurable multi-gas monitors on the market. 

Sku: IND-VP5-K1231101111
On Back-Order
$1,768.01 CAD

  • Flexible sensor configurations detect up to five gases
  • With integral pump for confined spaces or without integral pump for personal protection
  • Custom start-up messages, alarm action messages, and acknowledgeable gas alerts
  • Man-down alarm and dedicated panic button
  • User and site tracking with iAssign™ Technology
  • Rugged IP68 dust and water rating and Guaranteed for Life™ warranty*
  • Compatible with most Ventis™ MX4 accessories
  • Dock overdue and maintenance reminders
  • iNet® and DSX docking station ready

Specification

Detail Description

TYPICAL RANGE OF GASES DETECTED

CATALYTIC BEAD

Combustible Gases

0-100% LEL in 1% increments

Methane (CH4)

0-5% of vol in 0.01% increments

ELECTROCHEMICAL

Ammonia (NH3)

0-500 ppm in 1 ppm increments

Carbon Monoxide (CO)

0-2,000 ppm in 1 ppm increments

Carbon Monoxide (CO/H2 low)

0-1,000 ppm in 1 ppm increments

Carbon Monoxide/Hydrogen Sulfide

DUOTOX

CO

0-1,500 ppm in 1 ppm increments

H2S

0-500 ppm in 0.1 ppm increments

Hydrogen Sulfide (H2S)

0-500 ppm in 0.1 ppm increments

Hydrogen Cyanide (HCN)

0-30 ppm in 0.1 ppm increments

Nitrogen Dioxide (NO2)

0-150 ppm in 0.1 ppm increments

Oxygen (O2)

0-30% of vol in 0.1% increments

Sulfur Dioxide (SO2)

0-150 ppm in 0.1 ppm increments

INFRARED

Carbon Dioxide/Hydrocarbons

Dual IR Cell

CO2

0-5% vol in 0.01% increments

HC

0-100% LEL in 1% increments

Carbon Dioxide/Methane

Dual IR Cell

CO2

0-5% vol in 0.01% increments

CH4

0-5% vol in 0.01% increments

CH4

5-100% vol in 0.1% increments

 

GENERAL SPECIFICATIONS

KEYPAD

Two buttons for operation. Dedicated panic button.

DATA LOG

At least 3 months at 10-second intervals

EVENT LOGGING

60 alarm events

INGRESS PROTECTION

IP68 (submersion at 1.5 meters for 1 hour)

CASE MATERIAL

Polycarbonate with protective rubber overmold

DIMENSIONS

104 x 58 x 36 mm (4.1 x 2.3 x 1.4 in) without pump

 

172 x 67 x 65 mm (6.8 x 2.6 x 2.6 in) with pump

WEIGHT

200 g (7.05 oz), typical without pump

 

390 g (13.76 oz), typical with pump

TEMPERATURE RANGE

-40 °C to 50 °C (-40 °F to 122 °F)

HUMIDITY RANGE

15%-95% non-condensing (continuous)

DISPLAY/READOUT

Backlit liquid crystal display (LCD)

POWER SOURCE/RUN TIME

Rechargeable lithium-ion battery pack with LEL

 

(12 hours typical @ 20 ºC) – without pump

 

Rechargeable extended-range lithium-ion battery pack with LEL

 

(24 hours typical @ 20 ºC) – without pump

 

(18 hours typical @ 20 ºC) – with pump

 

Rechargeable lithium-ion battery pack with IR

 

(36 hours typical @ 20 ºC) – without pump

 

Rechargeable extended-range lithium-ion battery pack with IR

 

(72 hours typical @ 20 ºC) – without pump

 

(32 hours typical @ 20 ºC) – with pump

ALARMS

Four visual alarm LEDs (two red, two blue); 95 decibel (dB) audible alarm at a distance of 10 cm (3.94 in); Vibration alarm

SENSORS

Combustible Gases/Methane – Catalytic Bead. O2, CO, CO/H2 low, H2S, HCN, NH3, NO2, SO2 – Electrochemical. CO2/HC, CO/CH4 - Infrared

CERTIFICATIONS

UL

Class I, Division 1, Groups A, B, C, and D, in the Temperature Class T4

 

Class II, Division 1, Groups E, F, and G, in the Temperature Class T4

 

Class I, Zone 0, AEx ia IIC, in the Temperature Class T4

 

Class I, Zone 1, AEx d ia II C, in the Temperature Class T4, with IR sensor

ATEX

Equipment Group and Category II 1G, Ex ia IIC, with the protection category Ga, in the Temperature Class T4

 

Equipment Group and Category II 2G, Ex d ia IIC, with the protection category Gb, in the Temperature Class T4, with IR sensor

IECEx

Class I, Zone 0, Ex ia IIC, with the protection technique Ga, in the Temperature Class T4

 

Class I, Zone 1, Ex d ia IIC, with the protection technique Gb, in the

Temperature Class T4, with IR sensor

CSA

Class I, Division 1, Groups A, B, C, and D, in the Temperature Class T4

 

Class I, Zone 1, Ex d ia IIC, in the Temperature Class T4

SUPPLIED WITH MONITOR

Calibration Cup (Ventis), Sample Tubing (Ventis with pump), Reference Guide

REFERENCE GUIDE LANGUAGE

English, French, Spanish, German

WARRANTY

Guaranteed for Life. Warranted for as long as the instrument is supported by Industrial Scientific Corporation (excludes sensors, batteries, and filters). O2, LEL, CO, and H2S sensors warranted for three years. All other sensors warranted for two years. Pumps and batteries are warranted for two years.

Supplied with Monitor:

  • Calibration Cup (Ventis)
  • Sample Tubing (Ventis with pump)
  • Reference Guide

Related Products