Canada’s Most Trusted Fluke Store

Trade professionals know it: Fluke is the global standard in test tools. From the world’s most depended-on digital multimeters to clamp meters, electrical testers, ground resistant testers, insulation testers, thermal imagers and process tools, Fluke leads the way.

As a longtime authorized Fluke dealer, Kingsway Instruments is the go-to supplier for Canadian industry and trade pros. Our fanatical commitment to service is as legendary as Fluke's reputation for quality. Since 1969 we have continuously set the standard for speed, quick service turnarounds and low prices on Fluke multimeters and other electrical test products.

Canada’s Most Trusted Fluke Store

{"id":7907873423550,"title":"Fluke 9009 Dual Dry Block Temperature Calibrator","handle":"fluke-9009-dual-dry-block-temperature-calibrator","description":"\u003cp\u003eThe Model 9009 includes two independently controlled temperature blocks. The hot block provides temperatures from 50 °C to 350 °C, while the cold block covers the range –15 °C to 110 °C. Each block is controlled by a precision Hart Scientific temperature controller. These aren’t some off-the-shelf controllers we glued into a box. These are Hart Scientific controllers from the leading temperature company in the world.\u003c\/p\u003e\n\u003cp\u003eEach temperature block includes two wells with removable inserts. You can calibrate four probes at once, or you can calibrate two probes at the same time with an external reference (like Hart’s Model 1521 LLK Thermometer), or you can use the two temperature wells to get quick “zero\" and “span\" references for transmitter calibrations.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDouble your productivity or cut your calibration time in half\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperatures from –15 °C to 350 °C in one unit\u003c\/li\u003e\n\u003cli\u003eTwo wells in each block for simultaneous comparison calibrations\u003c\/li\u003e\n\u003cli\u003eRugged, lightweight, water-resistant enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou’ve been asking for it and now we’re making it for you. Hart’s new Model 9009 Industrial Dual-Block Calibrator lets you calibrate at hot and cold temperatures at the same time. Double your productivity or cut your calibration time in half—either way you look at it, your in-field temperature calibrations just got easier.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"3\"\u003e\u003cb data-mce-fragment=\"1\"\u003eGeneral Specifications\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eHot block\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eCold block\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRange\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e50°C to 350°C (122°F to 662°F)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e–15°C to 110°C (5°F to 230°F)\u003cbr data-mce-fragment=\"1\"\u003e(–8°C [18°F] with hot block at 350°C [662°F])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e±0.6°C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e±0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStability\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e±0.05°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWell-to-well uniformity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e0.1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eHeating times\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e30 minutes from 25°C to 350°C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e15 minutes from 25°C to 110°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eCooling times\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e40 minutes from 350°C to 100°C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e16 minutes from 25°C to –15°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStabilization times\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e8 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWell depth\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e4 in (102 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRemovable inserts\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003eTwo 6.4 mm (1\/4 in) and two 4.8 mm (3\/16 in) inserts included; see ordering information for other available inserts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eComputer interface\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003eRS-232 included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePower\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e115 V AC (±10 %), 3 A, or\u003cbr data-mce-fragment=\"1\"\u003e230 V AC (±10 %), 2 A, specify, 50\/60 Hz, 280 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSize (H x W x D)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e178 x 267 x 248 mm (7 x 10.5 x 9.75 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e4.5 kg (10 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eNIST-traceable calibration\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eData at 50°C, 100°C, 150°C, 200°C, 250°C, 300°C, and 350°C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eData at –8°C, 0°C, 25°C, 50°C, 75°C, 100°C, and 110°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cli\u003eDry Well\u003c\/li\u003e\n\u003cli\u003eReport of Calibration with Calibration Label\u003c\/li\u003e\n\u003cli\u003e2 x 3102-3 ( 3\/16\") and two 3102-4 (¼\") Inserts\u003c\/li\u003e\n\u003cli\u003ePower Cord\u003c\/li\u003e\n\u003cli\u003eRS-232 Cable\u003c\/li\u003e\n\u003cli\u003eInsert Removal Tool\u003c\/li\u003e\n\u003cli\u003eUser's Manual\u003c\/li\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_9009_Dual-Well_Dry-Well_Spec_Sheet.pdf?v=1708616638\" target=\"_blank\" title=\"Fluke 9009 Datasheet\" rel=\"noopener noreferrer\"\u003eFluke 9009 Datasheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2024-02-22T08:38:18-07:00","created_at":"2024-02-22T08:38:18-07:00","vendor":"Fluke","type":"Dry Blocks","tags":[],"price":1153688,"price_min":1153688,"price_max":1153688,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":43576565072062,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-9009-B-156","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 9009 Dual Dry Block Temperature Calibrator","public_title":null,"options":["Default Title"],"price":1153688,"weight":5443,"compare_at_price":null,"inventory_management":"shopify","barcode":"0 95969 12842 1","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/files\/Fluke9009Pic1.jpg?v=1708616526","\/\/kingswayinstruments.com\/cdn\/shop\/files\/Fluke9009Pic2.jpg?v=1708616535"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/Fluke9009Pic1.jpg?v=1708616526","options":["Title"],"media":[{"alt":null,"id":27037241770174,"position":1,"preview_image":{"aspect_ratio":0.863,"height":313,"width":270,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/Fluke9009Pic1.jpg?v=1708616526"},"aspect_ratio":0.863,"height":313,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/Fluke9009Pic1.jpg?v=1708616526","width":270},{"alt":null,"id":27037243539646,"position":2,"preview_image":{"aspect_ratio":1.333,"height":750,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/Fluke9009Pic2.jpg?v=1708616535"},"aspect_ratio":1.333,"height":750,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/Fluke9009Pic2.jpg?v=1708616535","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe Model 9009 includes two independently controlled temperature blocks. The hot block provides temperatures from 50 °C to 350 °C, while the cold block covers the range –15 °C to 110 °C. Each block is controlled by a precision Hart Scientific temperature controller. These aren’t some off-the-shelf controllers we glued into a box. These are Hart Scientific controllers from the leading temperature company in the world.\u003c\/p\u003e\n\u003cp\u003eEach temperature block includes two wells with removable inserts. You can calibrate four probes at once, or you can calibrate two probes at the same time with an external reference (like Hart’s Model 1521 LLK Thermometer), or you can use the two temperature wells to get quick “zero\" and “span\" references for transmitter calibrations.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDouble your productivity or cut your calibration time in half\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperatures from –15 °C to 350 °C in one unit\u003c\/li\u003e\n\u003cli\u003eTwo wells in each block for simultaneous comparison calibrations\u003c\/li\u003e\n\u003cli\u003eRugged, lightweight, water-resistant enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou’ve been asking for it and now we’re making it for you. Hart’s new Model 9009 Industrial Dual-Block Calibrator lets you calibrate at hot and cold temperatures at the same time. Double your productivity or cut your calibration time in half—either way you look at it, your in-field temperature calibrations just got easier.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"3\"\u003e\u003cb data-mce-fragment=\"1\"\u003eGeneral Specifications\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eHot block\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eCold block\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRange\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e50°C to 350°C (122°F to 662°F)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e–15°C to 110°C (5°F to 230°F)\u003cbr data-mce-fragment=\"1\"\u003e(–8°C [18°F] with hot block at 350°C [662°F])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e±0.6°C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e±0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStability\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e±0.05°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWell-to-well uniformity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e0.1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eHeating times\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e30 minutes from 25°C to 350°C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e15 minutes from 25°C to 110°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eCooling times\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e40 minutes from 350°C to 100°C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e16 minutes from 25°C to –15°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStabilization times\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e8 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWell depth\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e4 in (102 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRemovable inserts\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003eTwo 6.4 mm (1\/4 in) and two 4.8 mm (3\/16 in) inserts included; see ordering information for other available inserts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eComputer interface\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003eRS-232 included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePower\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e115 V AC (±10 %), 3 A, or\u003cbr data-mce-fragment=\"1\"\u003e230 V AC (±10 %), 2 A, specify, 50\/60 Hz, 280 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSize (H x W x D)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e178 x 267 x 248 mm (7 x 10.5 x 9.75 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e4.5 kg (10 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eNIST-traceable calibration\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eData at 50°C, 100°C, 150°C, 200°C, 250°C, 300°C, and 350°C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eData at –8°C, 0°C, 25°C, 50°C, 75°C, 100°C, and 110°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cli\u003eDry Well\u003c\/li\u003e\n\u003cli\u003eReport of Calibration with Calibration Label\u003c\/li\u003e\n\u003cli\u003e2 x 3102-3 ( 3\/16\") and two 3102-4 (¼\") Inserts\u003c\/li\u003e\n\u003cli\u003ePower Cord\u003c\/li\u003e\n\u003cli\u003eRS-232 Cable\u003c\/li\u003e\n\u003cli\u003eInsert Removal Tool\u003c\/li\u003e\n\u003cli\u003eUser's Manual\u003c\/li\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_9009_Dual-Well_Dry-Well_Spec_Sheet.pdf?v=1708616638\" target=\"_blank\" title=\"Fluke 9009 Datasheet\" rel=\"noopener noreferrer\"\u003eFluke 9009 Datasheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 9009 Dual Dry Block Temperature Calibrator

Fluke 9009 Dual Dry Block Temperature Calibrator

$11,536.88 CAD

The Model 9009 includes two independently controlled temperature blocks. The hot block provides temperatures from 50 °C to 350 °C, while the cold block covers the range –15 °C to 110 °C. Each block is controlled by a precision Hart Scientific temperature controller. These aren’t some off-the-shelf controllers we glued into a box. These are Hart ...


More Info
{"id":7188937801918,"title":"Fluke FEV100 Electric Vehicle Charging Station Adapter w\/ Type 1 Connector and Cable","handle":"fluke-fev100-electric-vehicle-charging-station-adapter-w-type-1-connector-and-cable","description":"\u003cp\u003eMonitor the nominal voltage of the station voltage by connecting this adapter and selecting either state C or D using the rotary switch to start the charging cycle. There is no need to bring an electric vehicle onsite for EVSE troubleshooting: the adapter acts as an electric vehicle when connected to an EVSE for effortless performance and maintenance testing.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCheck protective earth for correct wiring and functioning with the PE pre-test feature. \u003c\/li\u003e\n\u003cli\u003ePerform GFCI troubleshooting of EVSE and verify operation within safety standards. \u003c\/li\u003e\n\u003cli\u003eTest charging states of EVSE with CP state simulation. \u003c\/li\u003e\n\u003cli\u003eVerify charging voltage and maximum available current using a multimeter.\u003c\/li\u003e\n\u003cli\u003eSAE J1772 compliant to North American standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003eUL1\/N = 120 V, UL2\/N = 120 V, UL1\/L2 = 208 V, 60 Hz (three-phase system)\u003cbr\u003eUL1\/N = 120 V, UL2\/N = 120 V, UL1\/L2 = 240 V, 60 Hz (single-phase system)\u003cbr\u003e±10 % voltage fluctuations from nominal 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEV connector (EVC-13)\u003c\/td\u003e\n\u003ctd\u003eSAE J1772 socket, 16 A (type 1, 5P single-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal power consumption\u003c\/td\u003e\n\u003ctd\u003e2 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eOperating: -4 to 104°F (-20 to 40 °C)\u003cbr\u003eStorage: -4 to 122°F (-20 to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eOperating range: 10 to 85% relative humidity non-condensing\u003cbr\u003eStorage: 0 to 85% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e6561’ (2000 m) maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.66 x 4.33 x 1.77\" (220 x 110 × 45 mm) without cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.4 lbs (2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke FEV100\/BASIC Test Adapter\u003c\/li\u003e\n\u003cli\u003eFluke FEV-CON\/TY1 Type 1 Connector \u0026amp; Cable\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_FEV100-ds-w.pdf?v=1647626187\" title=\"Fluke FEV100 Electric Vehicle Charging Station Adapter Datasheet\" target=\"_blank\"\u003eFluke FEV100 Electric Vehicle Charging Station Adapter Datasheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2022-03-18T12:03:43-06:00","created_at":"2022-03-18T12:03:42-06:00","vendor":"Fluke","type":"Electrical Testers","tags":[],"price":160000,"price_min":160000,"price_max":160000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41297255170238,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-FEV100\/TY1","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke FEV100 Electric Vehicle Charging Station Adapter w\/ Type 1 Connector and Cable","public_title":null,"options":["Default Title"],"price":160000,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/FlukeFEV-TY1.webp?v=1647626909"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FlukeFEV-TY1.webp?v=1647626909","options":["Title"],"media":[{"alt":null,"id":23208845213886,"position":1,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FlukeFEV-TY1.webp?v=1647626909"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FlukeFEV-TY1.webp?v=1647626909","width":500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eMonitor the nominal voltage of the station voltage by connecting this adapter and selecting either state C or D using the rotary switch to start the charging cycle. There is no need to bring an electric vehicle onsite for EVSE troubleshooting: the adapter acts as an electric vehicle when connected to an EVSE for effortless performance and maintenance testing.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCheck protective earth for correct wiring and functioning with the PE pre-test feature. \u003c\/li\u003e\n\u003cli\u003ePerform GFCI troubleshooting of EVSE and verify operation within safety standards. \u003c\/li\u003e\n\u003cli\u003eTest charging states of EVSE with CP state simulation. \u003c\/li\u003e\n\u003cli\u003eVerify charging voltage and maximum available current using a multimeter.\u003c\/li\u003e\n\u003cli\u003eSAE J1772 compliant to North American standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003eUL1\/N = 120 V, UL2\/N = 120 V, UL1\/L2 = 208 V, 60 Hz (three-phase system)\u003cbr\u003eUL1\/N = 120 V, UL2\/N = 120 V, UL1\/L2 = 240 V, 60 Hz (single-phase system)\u003cbr\u003e±10 % voltage fluctuations from nominal 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEV connector (EVC-13)\u003c\/td\u003e\n\u003ctd\u003eSAE J1772 socket, 16 A (type 1, 5P single-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal power consumption\u003c\/td\u003e\n\u003ctd\u003e2 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eOperating: -4 to 104°F (-20 to 40 °C)\u003cbr\u003eStorage: -4 to 122°F (-20 to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eOperating range: 10 to 85% relative humidity non-condensing\u003cbr\u003eStorage: 0 to 85% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e6561’ (2000 m) maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.66 x 4.33 x 1.77\" (220 x 110 × 45 mm) without cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.4 lbs (2 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke FEV100\/BASIC Test Adapter\u003c\/li\u003e\n\u003cli\u003eFluke FEV-CON\/TY1 Type 1 Connector \u0026amp; Cable\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_FEV100-ds-w.pdf?v=1647626187\" title=\"Fluke FEV100 Electric Vehicle Charging Station Adapter Datasheet\" target=\"_blank\"\u003eFluke FEV100 Electric Vehicle Charging Station Adapter Datasheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke FEV100 Electric Vehicle Charging Station Adapter w/ Type 1 Connector and Cable

Fluke FEV100 Electric Vehicle Charging Station Adapter w/ Type 1 Connector and Cable

$1,600.00 CAD

Monitor the nominal voltage of the station voltage by connecting this adapter and selecting either state C or D using the rotary switch to start the charging cycle. There is no need to bring an electric vehicle onsite for EVSE troubleshooting: the adapter acts as an electric vehicle when connected to an EVSE for effortless performance and mainte...


More Info
Sold Out
Fluke 376 True-RMS AC/DC Clamp Meter, No Fluke Connect
{"id":7188852310206,"title":"Fluke 376 True-RMS AC\/DC Clamp Meter, No Fluke Connect","handle":"fluke-376-true-rms-ac-dc-clamp-meter-no-fluke-connect","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 376 True-rms AC\/DC Clamp Meter includes the iFlex™ Flexible Current Probe and measures up to  1000 V and 1000 A, AC or DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*This unit is no longer available - See the Fluke 376FC replacement*\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eiFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)\u003c\/li\u003e\n\u003cli\u003eTPAK magnetic hanging strap (included)\u003c\/li\u003e\n\u003cli\u003eIntegrated VFD low pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V safety rating\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Capability\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1000 A ac and dc current measurement\u003c\/li\u003e\n\u003cli\u003e2500 A ac current measurement with iFlex flexible current probe\u003c\/li\u003e\n\u003cli\u003e1000 V ac and dc voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue-rms voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eFrequency measurement to 500 Hz with body jaw and iFlex\u003c\/li\u003e\n\u003cli\u003eResistance measurement to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003e500 mV dc measurement range to interface with other accessories\u003c\/li\u003e\n\u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000V, CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent AC Range\u003c\/td\u003e\n\u003ctd\u003e999.9A with clamp jaws\u003cbr\u003e2500A with iFlex flexible current clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC Range\u003c\/td\u003e\n\u003ctd\u003e999.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e1000V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV DC Range\u003c\/td\u003e\n\u003ctd\u003e500mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOhms Range\u003c\/td\u003e\n\u003ctd\u003e60.00kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e5 to 500.0Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1μF to 1,000μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 376F Clamp Meter\u003c\/li\u003e\n\u003cli\u003e18-inch iFlex® Flexible Current Probe\u003c\/li\u003e\n\u003cli\u003eTPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eTL75 test leads\u003c\/li\u003e\n\u003cli\u003eTwo AA Alkaline batteries\u003c\/li\u003e\n\u003cli\u003eCoated instruction card\u003c\/li\u003e\n\u003cli\u003eSafety information sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","published_at":"2022-03-18T09:20:20-06:00","created_at":"2022-03-18T09:18:10-06:00","vendor":"Fluke","type":"Clamp Meters","tags":[],"price":0,"price_min":0,"price_max":0,"available":false,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41297019175102,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-376","requires_shipping":true,"taxable":true,"featured_image":null,"available":false,"name":"Fluke 376 True-RMS AC\/DC Clamp Meter, No Fluke Connect","public_title":null,"options":["Default Title"],"price":0,"weight":1361,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke376NonFC.jpg?v=1647616775"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke376NonFC.jpg?v=1647616775","options":["Title"],"media":[{"alt":null,"id":23208482701502,"position":1,"preview_image":{"aspect_ratio":1.333,"height":600,"width":800,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke376NonFC.jpg?v=1647616775"},"aspect_ratio":1.333,"height":600,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke376NonFC.jpg?v=1647616775","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 376 True-rms AC\/DC Clamp Meter includes the iFlex™ Flexible Current Probe and measures up to  1000 V and 1000 A, AC or DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*This unit is no longer available - See the Fluke 376FC replacement*\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eiFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)\u003c\/li\u003e\n\u003cli\u003eTPAK magnetic hanging strap (included)\u003c\/li\u003e\n\u003cli\u003eIntegrated VFD low pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V safety rating\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Capability\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1000 A ac and dc current measurement\u003c\/li\u003e\n\u003cli\u003e2500 A ac current measurement with iFlex flexible current probe\u003c\/li\u003e\n\u003cli\u003e1000 V ac and dc voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue-rms voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eFrequency measurement to 500 Hz with body jaw and iFlex\u003c\/li\u003e\n\u003cli\u003eResistance measurement to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003e500 mV dc measurement range to interface with other accessories\u003c\/li\u003e\n\u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000V, CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent AC Range\u003c\/td\u003e\n\u003ctd\u003e999.9A with clamp jaws\u003cbr\u003e2500A with iFlex flexible current clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC Range\u003c\/td\u003e\n\u003ctd\u003e999.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e1000V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV DC Range\u003c\/td\u003e\n\u003ctd\u003e500mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOhms Range\u003c\/td\u003e\n\u003ctd\u003e60.00kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e5 to 500.0Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1μF to 1,000μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 376F Clamp Meter\u003c\/li\u003e\n\u003cli\u003e18-inch iFlex® Flexible Current Probe\u003c\/li\u003e\n\u003cli\u003eTPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eTL75 test leads\u003c\/li\u003e\n\u003cli\u003eTwo AA Alkaline batteries\u003c\/li\u003e\n\u003cli\u003eCoated instruction card\u003c\/li\u003e\n\u003cli\u003eSafety information sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e"}
Fluke 376 True-RMS AC/DC Clamp Meter, No Fluke Connect

Fluke 376 True-RMS AC/DC Clamp Meter, No Fluke Connect

Call for pricing

The Fluke 376 True-rms AC/DC Clamp Meter includes the iFlex™ Flexible Current Probe and measures up to  1000 V and 1000 A, AC or DC. *This unit is no longer available - See the Fluke 376FC replacement* Overview iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (include...


More Info
{"id":7166874550462,"title":"Fluke 375 True-RMS AC\/DC Clamp Meter, No Fluke Connect","handle":"fluke-375-true-rms-ac-dc-clamp-meter-no-fluke-connect","description":"\u003cp\u003e\u003cspan\u003eThe Fluke 375 (Non-FC) True-rms AC\/DC Clamp Meter measures up to 1000 V and 600 A, AC or DC. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*This unit does not have FC Fluke Connect - See the Fluke 375FC for this model*\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with TPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eIntegrated VFD low pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V safety rating\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Capability\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e600 A ac and dc current measurement\u003c\/li\u003e\n\u003cli\u003e1000 V ac and dc voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue-rms voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eResistance measurement to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000V, CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent AC Range\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC Range\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage AC\/DC Range\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003c!-- split --\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 375 FC TRMS AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003cli\u003eTL75 Test Leads\u003c\/li\u003e\n\u003cli\u003e2 x AA Alkaline Batteries\u003c\/li\u003e\n\u003cli\u003eCoated Instruction Card\u003c\/li\u003e\n\u003cli\u003eSafety Information Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","published_at":"2022-02-23T08:18:02-07:00","created_at":"2022-02-23T08:18:03-07:00","vendor":"Fluke","type":"Clamp Meters","tags":[],"price":71500,"price_min":71500,"price_max":71500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41226828775614,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-375","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 375 True-RMS AC\/DC Clamp Meter, No Fluke Connect","public_title":null,"options":["Default Title"],"price":71500,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke375NonFC.jpg?v=1645629621"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke375NonFC.jpg?v=1645629621","options":["Title"],"media":[{"alt":null,"id":23123019464894,"position":1,"preview_image":{"aspect_ratio":1.0,"height":565,"width":565,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke375NonFC.jpg?v=1645629621"},"aspect_ratio":1.0,"height":565,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke375NonFC.jpg?v=1645629621","width":565}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Fluke 375 (Non-FC) True-rms AC\/DC Clamp Meter measures up to 1000 V and 600 A, AC or DC. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*This unit does not have FC Fluke Connect - See the Fluke 375FC for this model*\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with TPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eIntegrated VFD low pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V safety rating\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Capability\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e600 A ac and dc current measurement\u003c\/li\u003e\n\u003cli\u003e1000 V ac and dc voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue-rms voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eResistance measurement to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000V, CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent AC Range\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC Range\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage AC\/DC Range\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003c!-- split --\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 375 FC TRMS AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003cli\u003eTL75 Test Leads\u003c\/li\u003e\n\u003cli\u003e2 x AA Alkaline Batteries\u003c\/li\u003e\n\u003cli\u003eCoated Instruction Card\u003c\/li\u003e\n\u003cli\u003eSafety Information Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e"}
Fluke 375 True-RMS AC/DC Clamp Meter, No Fluke Connect

Fluke 375 True-RMS AC/DC Clamp Meter, No Fluke Connect

$715.00 CAD

The Fluke 375 (Non-FC) True-rms AC/DC Clamp Meter measures up to 1000 V and 600 A, AC or DC.  *This unit does not have FC Fluke Connect - See the Fluke 375FC for this model* Overview Compatible with TPAK magnetic hanging strap Integrated VFD low pass filter for accurate motor drive measurements Proprietary inrush measurement technology to filt...


More Info
Fluke IRR1-SOL Solar Irradiance Meter

Irradiance Meters

$571.28 CAD
{"id":7094654927038,"title":"Fluke IRR1-SOL Solar Irradiance Meter","handle":"fluke-irr1-sol-solar-irradiance-meter","description":"\u003cp\u003e\u003cspan\u003eIf you’re surveying, installing, executing maintenance or checking performance of solar panels or a photovoltaic system, the Fluke IRR1-SOL Irradiance Meter gives you the 4 critical measurements needed all in one easy-to-use tool. Make instantaneous measurements to determine the watt per square meter solar irradiation, required by IEC 62446-1 standard. Measure temperature by either placing the meter directly on the panel or by connecting the external probe. Find cardinal direction with the compass, and verify inclination of a roof or panel with the tilt function.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure solar irradiance, ambient and PV module temperature, array orientation and tilt angles\u003c\/li\u003e\n\u003cli\u003eMake instantaneous measurements to determine the watts per square meter solar irradiation, required by IEC 62446-1 standard\u003c\/li\u003e\n\u003cli\u003eHigh contrast LCD with large numbers for easy readability in direct sunlight\u003c\/li\u003e\n\u003cli\u003eIncludes convenient carry case with shoulder strap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ch4\u003eFluke IRR1-SOL Specifications\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eIrradiance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e0 to 1400 W\/m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 W\/m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(5% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTemperature Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e-22 to 212°F (-30 to 100°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.2°F (0.1°C)\/1°F at \u0026gt;100°F (-17.22 at \u0026gt;37.77°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2°F (±1°C) at 14 to 167°F (-10 to 75°C)\u003cbr\u003e±4°F (±2°C) at -22 to 14°F (-30 to -10°C) and 167 to 212°F (75 to 100°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInclination Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e-90 to 90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Accuracy\u003c\/td\u003e\n\u003ctd\u003e±7°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003eMeter: -4 to 122°F (-20 to 50°C); humidity \u0026lt;80%, non-condensing\u003cbr\u003eExternal probe: -22 to 212°F (-30 to 100°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-22 to 140°F (-30 to 60°C); humidity \u0026lt;80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e0 to 6561.68' (0 to 2000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\n\u003ctd\u003eUSA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Protection\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd\u003e4 x AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life (Typical)\u003c\/td\u003e\n\u003ctd\u003e50 hours (\u0026gt;9000 readings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Power Off\u003c\/td\u003e\n\u003ctd\u003e30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.90 x 3.14 x 1.37\" (150 x 80 x 35 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 lbs (231 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSolar Irradiance Meter\u003c\/li\u003e\n\u003cli\u003eExternal Temperature Probe with Suction Cup\u003c\/li\u003e\n\u003cli\u003eCarrying Case with Shoulder Strap\u003c\/li\u003e\n\u003cli\u003e4 x AA Alkaline Batteries\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_IRR1-SOL_Irradiance_Meter_-_Datasheet_EN.pdf?v=1639511042\" target=\"_blank\" title=\"Fluke IRR1-SOL Solar Irradiance Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke IRR1-SOL Solar Irradiance Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-12-14T12:55:20-07:00","created_at":"2021-12-14T12:55:18-07:00","vendor":"Fluke","type":"Irradiance Meters","tags":[],"price":57128,"price_min":57128,"price_max":57128,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41024883032254,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-IRR1-SOL","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke IRR1-SOL Solar Irradiance Meter","public_title":null,"options":["Default Title"],"price":57128,"weight":1361,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/FlukeIRR1-SOL_2.jpg?v=1639512362","\/\/kingswayinstruments.com\/cdn\/shop\/products\/FlukeIRR1-SOL_1.jpg?v=1639512375","\/\/kingswayinstruments.com\/cdn\/shop\/products\/FlukeIRR1-SOL.jpg?v=1639512385"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FlukeIRR1-SOL_2.jpg?v=1639512362","options":["Title"],"media":[{"alt":null,"id":22840745918654,"position":1,"preview_image":{"aspect_ratio":0.54,"height":500,"width":270,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FlukeIRR1-SOL_2.jpg?v=1639512362"},"aspect_ratio":0.54,"height":500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FlukeIRR1-SOL_2.jpg?v=1639512362","width":270},{"alt":null,"id":22840746934462,"position":2,"preview_image":{"aspect_ratio":1.5,"height":348,"width":522,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FlukeIRR1-SOL_1.jpg?v=1639512375"},"aspect_ratio":1.5,"height":348,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FlukeIRR1-SOL_1.jpg?v=1639512375","width":522},{"alt":null,"id":22840747491518,"position":3,"preview_image":{"aspect_ratio":1.0,"height":600,"width":600,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FlukeIRR1-SOL.jpg?v=1639512385"},"aspect_ratio":1.0,"height":600,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FlukeIRR1-SOL.jpg?v=1639512385","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eIf you’re surveying, installing, executing maintenance or checking performance of solar panels or a photovoltaic system, the Fluke IRR1-SOL Irradiance Meter gives you the 4 critical measurements needed all in one easy-to-use tool. Make instantaneous measurements to determine the watt per square meter solar irradiation, required by IEC 62446-1 standard. Measure temperature by either placing the meter directly on the panel or by connecting the external probe. Find cardinal direction with the compass, and verify inclination of a roof or panel with the tilt function.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure solar irradiance, ambient and PV module temperature, array orientation and tilt angles\u003c\/li\u003e\n\u003cli\u003eMake instantaneous measurements to determine the watts per square meter solar irradiation, required by IEC 62446-1 standard\u003c\/li\u003e\n\u003cli\u003eHigh contrast LCD with large numbers for easy readability in direct sunlight\u003c\/li\u003e\n\u003cli\u003eIncludes convenient carry case with shoulder strap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ch4\u003eFluke IRR1-SOL Specifications\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eIrradiance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e0 to 1400 W\/m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 W\/m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(5% + 5 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTemperature Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e-22 to 212°F (-30 to 100°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.2°F (0.1°C)\/1°F at \u0026gt;100°F (-17.22 at \u0026gt;37.77°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2°F (±1°C) at 14 to 167°F (-10 to 75°C)\u003cbr\u003e±4°F (±2°C) at -22 to 14°F (-30 to -10°C) and 167 to 212°F (75 to 100°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInclination Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e-90 to 90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Accuracy\u003c\/td\u003e\n\u003ctd\u003e±7°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003eMeter: -4 to 122°F (-20 to 50°C); humidity \u0026lt;80%, non-condensing\u003cbr\u003eExternal probe: -22 to 212°F (-30 to 100°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-22 to 140°F (-30 to 60°C); humidity \u0026lt;80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e0 to 6561.68' (0 to 2000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\n\u003ctd\u003eUSA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Protection\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd\u003e4 x AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life (Typical)\u003c\/td\u003e\n\u003ctd\u003e50 hours (\u0026gt;9000 readings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Power Off\u003c\/td\u003e\n\u003ctd\u003e30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.90 x 3.14 x 1.37\" (150 x 80 x 35 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 lbs (231 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSolar Irradiance Meter\u003c\/li\u003e\n\u003cli\u003eExternal Temperature Probe with Suction Cup\u003c\/li\u003e\n\u003cli\u003eCarrying Case with Shoulder Strap\u003c\/li\u003e\n\u003cli\u003e4 x AA Alkaline Batteries\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_IRR1-SOL_Irradiance_Meter_-_Datasheet_EN.pdf?v=1639511042\" target=\"_blank\" title=\"Fluke IRR1-SOL Solar Irradiance Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke IRR1-SOL Solar Irradiance Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke IRR1-SOL Solar Irradiance Meter

Fluke IRR1-SOL Solar Irradiance Meter

$571.28 CAD

If you’re surveying, installing, executing maintenance or checking performance of solar panels or a photovoltaic system, the Fluke IRR1-SOL Irradiance Meter gives you the 4 critical measurements needed all in one easy-to-use tool. Make instantaneous measurements to determine the watt per square meter solar irradiation, required by IEC 62446-1 st...


More Info
Fluke 417D Laser Distance Meter

Laser Distance Meters

$201.27 CAD
{"id":7052874678462,"title":"Fluke 417D Laser Distance Meter","handle":"fluke-417d-laser-distance-meter","description":"\u003cp\u003e\u003cspan\u003eThe Fluke 417D is accurate, durable, and easy to use—just point and shoot. The simple design and easy, one-button measurement operation allows you to minimize time spent measuring and maximize the reliability of measurements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLarge, 2-line illuminated LCD screen.\u003c\/li\u003e\n\u003cli\u003eThree different measurement tasks can be completed quickly and easily with one hand.\u003c\/li\u003e\n\u003cli\u003eThe bright laser is clearly visible, so you can always see your target point even from a hard-to-reach spot or long distance.\u003c\/li\u003e\n\u003cli\u003eDesigned for both indoor and outdoor applications.\u003c\/li\u003e\n\u003cli\u003eOperates with the Fluke durability and quality you expect.\u003c\/li\u003e\n\u003cli\u003eProtected by a 3-year warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003e417D\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical range [1]\u003c\/td\u003e\n\u003ctd\u003e0.2-40 m\/0.6-131 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical measuring tolerance* [1]\u003c\/td\u003e\n\u003ctd\u003e2.0 mm ± 1.5 mm\/± 0.06 in ***\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum measuring tolerance [2]\u003c\/td\u003e\n\u003ctd\u003e± 3.0 mm\/0.12 in ***\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy up to 10m (+\/-)\u003c\/td\u003e\n\u003ctd\u003e± 2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e2 line\/1 mm\/1\/32 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay illumination\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser point at distance\u003c\/td\u003e\n\u003ctd\u003e6\/30\/60 mm (10\/40\/100 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArea\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits setting (smallest units displayed)\u003c\/td\u003e\n\u003ctd\u003e0,000m, 0' 00'' 1\/32, 0 in 1\/32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto laser switch off\u003c\/td\u003e\n\u003ctd\u003e90 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto power switch off\u003c\/td\u003e\n\u003ctd\u003e180 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser class\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser type\u003c\/td\u003e\n\u003ctd\u003e635 nm, \u0026lt;1 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life (2 x AAA) 1.5 V NEDA 24A\/IEC LR03\u003c\/td\u003e\n\u003ctd\u003eUp to 3,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (Hx W x D)\u003c\/td\u003e\n\u003ctd\u003e11.9 x 3.8 x 2.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with batteries)\u003c\/td\u003e\n\u003ctd\u003e95g (3.35 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range: Storage\u003c\/td\u003e\n\u003ctd\u003e-25 °C to 70 °C (-13 °F to 158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range: Operation\u003c\/td\u003e\n\u003ctd\u003e-10 °C to 50 °C (14 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration cycle\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum relative humidity\u003c\/td\u003e\n\u003ctd\u003e85 % @ 20°F to 120 °F\u003cbr\u003e(-7 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eCAN\/CSA-C22.2 No. 61010-1-04, UL Std. No. 61010-1 (2nd Edition), ISA-82.02.01, IEC Standard No. 61010-1:2001, EN60825-1:2007 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLaser Distance Meter\u003c\/li\u003e\n\u003cli\u003eLanyard\u003c\/li\u003e\n\u003cli\u003e2 x AAA Batteries\u003c\/li\u003e\n\u003cli\u003eUser's Manual\u003c\/li\u003e\n\u003cli\u003eQuick Reference Guide\u003c\/li\u003e\n\u003cli\u003eThree-Year Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke-417D-Laser-Distance-Measurer-ds-w.pdf?v=1636396262\" target=\"_blank\" title=\"Fluke 417D Laser Distance Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 417D Laser Distance Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-11-08T12:13:34-07:00","created_at":"2021-11-08T12:13:33-07:00","vendor":"Fluke","type":"Laser Distance Meters","tags":[],"price":20127,"price_min":20127,"price_max":20127,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":40917450522814,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-417D","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 417D Laser Distance Meter","public_title":null,"options":["Default Title"],"price":20127,"weight":454,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke417D.jpg?v=1636398816"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke417D.jpg?v=1636398816","options":["Title"],"media":[{"alt":null,"id":22679331995838,"position":1,"preview_image":{"aspect_ratio":0.54,"height":500,"width":270,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke417D.jpg?v=1636398816"},"aspect_ratio":0.54,"height":500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke417D.jpg?v=1636398816","width":270}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Fluke 417D is accurate, durable, and easy to use—just point and shoot. The simple design and easy, one-button measurement operation allows you to minimize time spent measuring and maximize the reliability of measurements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLarge, 2-line illuminated LCD screen.\u003c\/li\u003e\n\u003cli\u003eThree different measurement tasks can be completed quickly and easily with one hand.\u003c\/li\u003e\n\u003cli\u003eThe bright laser is clearly visible, so you can always see your target point even from a hard-to-reach spot or long distance.\u003c\/li\u003e\n\u003cli\u003eDesigned for both indoor and outdoor applications.\u003c\/li\u003e\n\u003cli\u003eOperates with the Fluke durability and quality you expect.\u003c\/li\u003e\n\u003cli\u003eProtected by a 3-year warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003e\u003cstrong\u003e417D\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical range [1]\u003c\/td\u003e\n\u003ctd\u003e0.2-40 m\/0.6-131 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical measuring tolerance* [1]\u003c\/td\u003e\n\u003ctd\u003e2.0 mm ± 1.5 mm\/± 0.06 in ***\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum measuring tolerance [2]\u003c\/td\u003e\n\u003ctd\u003e± 3.0 mm\/0.12 in ***\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy up to 10m (+\/-)\u003c\/td\u003e\n\u003ctd\u003e± 2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e2 line\/1 mm\/1\/32 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay illumination\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser point at distance\u003c\/td\u003e\n\u003ctd\u003e6\/30\/60 mm (10\/40\/100 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArea\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits setting (smallest units displayed)\u003c\/td\u003e\n\u003ctd\u003e0,000m, 0' 00'' 1\/32, 0 in 1\/32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto laser switch off\u003c\/td\u003e\n\u003ctd\u003e90 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto power switch off\u003c\/td\u003e\n\u003ctd\u003e180 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser class\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser type\u003c\/td\u003e\n\u003ctd\u003e635 nm, \u0026lt;1 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life (2 x AAA) 1.5 V NEDA 24A\/IEC LR03\u003c\/td\u003e\n\u003ctd\u003eUp to 3,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (Hx W x D)\u003c\/td\u003e\n\u003ctd\u003e11.9 x 3.8 x 2.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with batteries)\u003c\/td\u003e\n\u003ctd\u003e95g (3.35 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range: Storage\u003c\/td\u003e\n\u003ctd\u003e-25 °C to 70 °C (-13 °F to 158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range: Operation\u003c\/td\u003e\n\u003ctd\u003e-10 °C to 50 °C (14 °F to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration cycle\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum relative humidity\u003c\/td\u003e\n\u003ctd\u003e85 % @ 20°F to 120 °F\u003cbr\u003e(-7 °C to 50 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eCAN\/CSA-C22.2 No. 61010-1-04, UL Std. No. 61010-1 (2nd Edition), ISA-82.02.01, IEC Standard No. 61010-1:2001, EN60825-1:2007 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLaser Distance Meter\u003c\/li\u003e\n\u003cli\u003eLanyard\u003c\/li\u003e\n\u003cli\u003e2 x AAA Batteries\u003c\/li\u003e\n\u003cli\u003eUser's Manual\u003c\/li\u003e\n\u003cli\u003eQuick Reference Guide\u003c\/li\u003e\n\u003cli\u003eThree-Year Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke-417D-Laser-Distance-Measurer-ds-w.pdf?v=1636396262\" target=\"_blank\" title=\"Fluke 417D Laser Distance Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 417D Laser Distance Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 417D Laser Distance Meter

Fluke 417D Laser Distance Meter

$201.27 CAD

The Fluke 417D is accurate, durable, and easy to use—just point and shoot. The simple design and easy, one-button measurement operation allows you to minimize time spent measuring and maximize the reliability of measurements. Overview Large, 2-line illuminated LCD screen. Three different measurement tasks can be completed quickly and easily wi...


More Info
Fluke 1770 Series Three-Phase Power Quality Analyzers

Power Quality

From $11,527.35 CAD
{"id":7015265566910,"title":"Fluke 1770 Series Three-Phase Power Quality Analyzers","handle":"fluke-1770-series-three-phase-power-quality-analyzers","description":"\u003ch3\u003eAutomatic measurements. More flexibility. Better power quality troubleshooting.\u003c\/h3\u003e\n\u003cp\u003eReplacing the long standing Fluke 430 Series, the Fluke 1770 Series Three-Phase Power Quality Analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series offers automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord\u003c\/p\u003e\n\u003cp\u003eWith the 1770 Series you’ll never miss a critical power quality event—from fast transients up to 8 kV, harmonics up to 30 kHz, dips and swells, as well as the voltage, current, and power measurements that enable you to characterize your electrical system.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2\u003eAutomatic Measurement capture\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cdiv class=\"container-flex col-reverse\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eWhether you’re performing a quick system check or a detailed power quality study, consistent data is key. The Fluke 1770 Series offers a unique automatic measurement capture system that helps ensure you’re collecting the right data every time, while still giving you the flexibility to select and adjust specific parameters as needed. More than 500 power quality parameters are captured by default and the guided setup makes it easy to select the right parameters for the system you’re working on. Logged data is instantly viewable, downloadable, and shareable with Fluke Energy Analyze Plus software so you never need to wait to finish a session before reviewing results or analyzing data.\u003c\/p\u003e\n\u003ch3\u003eUltimate measurement confidence\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1770 Series are 2-in-1 devices that combine the troubleshooting functionality of a power quality meter with the robust analysis and logging capabilities of a standalone power quality analyzer—in a single, easy-to-use, handheld device.\u003c\/p\u003e\n\u003cp\u003eThe ‘PQ Meter’ function gives you immediate access to live onscreen data in the field so you can quickly identify potential problems while troubleshooting. The detailed ‘PQ Logging and Analysis’ function eliminates the complexity of performing power quality studies by guiding you through the setup process ensuring you’re capturing the right data every time. Couple these measurement modes with a unique measurement connection autocorrect function and you can be confident that you never need to worry about going back for a second measurement—even if you were unsure about what to look for when you started.\u003c\/p\u003e\n\u003ch3\u003eHigh-speed voltage transient capture\u003c\/h3\u003e\n\u003cp\u003eTransients negatively impact otherwise healthy systems every day and their potential to damage your equipment can’t be underestimated. Whether your system is experiencing impulsive or oscillatory transients, the results can be devastating and cause problems ranging from insulation failures to total equipment failures. The Fluke 1775 and Fluke 1777 incorporate advanced transient capture technology to help you clearly identify high-speed voltage transients, so you have the data you need to stop them in their tracks. The Fluke 1775 Power Quality Analyzer has 1MHz sampling capability to capture fast transients, while the Fluke 1777 Power Quality Analyzer has 20MHz sampling capability to capture the fastest transients in high detail.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\" itemprop=\"name\"\u003e\u003cstrong\u003eFluke 1773 Three-Phase Power Quality Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1773 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eI17XX-FLEX1500 24 iFLEX 1500A 24 IN (2.0M) current probes (set of four)\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clips (set of four)\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1M USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cords (US, EU, UK, AUS, BRA)\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eFLUKE-177X-4204, WI-FI\/BLE module\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cstrong\u003eFluke 1775 Three-Phase Power Quality Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1775 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eI17XX-FLEX1500 24 iFLEX 1500A 24 IN (2.0M) current probes (set of four)\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clips (set of four)\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1m USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cord\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eMP1-3R\/1B Magnet Probe set\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-HANGER magnetic hanging kit\u003c\/li\u003e\n\u003cli\u003eFLUKE-177X-4204, WI-FI\/BLE module\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003cli\u003eBlack soft case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cstrong\u003eFluke 1777\u003cspan\u003e \u003c\/span\u003eThree-Phase Power Quality Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1775 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eI17XX-FLEX1500 24 iFLEX 1500A 24 IN (2.0M) current probes (set of four)\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clips (set of four)\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1m USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cord\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eMP1-3R\/1B Magnet Probe set\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-HANGER magnetic hanging kit\u003c\/li\u003e\n\u003cli\u003eFLUKE-177X-4204, WI-FI\/BLE module\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003cli\u003eBlack soft case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1770_Series_Power_Quality_Analyzer_Datasheet.pdf?v=1636404123\" target=\"_blank\" title=\"Fluke 1770 Series Power Quality Datasheet\" rel=\"noopener noreferrer\"\u003eFluke 1770 Series Power Quality Datasheet\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e","published_at":"2021-10-14T12:47:42-06:00","created_at":"2021-10-14T12:47:42-06:00","vendor":"Fluke","type":"Power Quality","tags":[],"price":1152735,"price_min":1152735,"price_max":1892847,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":40814254194878,"title":"Fluke 1775","option1":"Fluke 1775","option2":null,"option3":null,"sku":"FLU-1775","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1770 Series Three-Phase Power Quality Analyzers - Fluke 1775","public_title":"Fluke 1775","options":["Fluke 1775"],"price":1514631,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969917674","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":40814254227646,"title":"Fluke 1777","option1":"Fluke 1777","option2":null,"option3":null,"sku":"FLU-1777","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1770 Series Three-Phase Power Quality Analyzers - Fluke 1777","public_title":"Fluke 1777","options":["Fluke 1777"],"price":1892847,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969919012","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":40814254260414,"title":"Fluke 1773","option1":"Fluke 1773","option2":null,"option3":null,"sku":"FLU-1773","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1770 Series Three-Phase Power Quality Analyzers - Fluke 1773","public_title":"Fluke 1773","options":["Fluke 1773"],"price":1152735,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969917667","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke1770SeriesPic1.jpg?v=1634238100"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke1770SeriesPic1.jpg?v=1634238100","options":["Model"],"media":[{"alt":null,"id":22427520270526,"position":1,"preview_image":{"aspect_ratio":1.448,"height":411,"width":595,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke1770SeriesPic1.jpg?v=1634238100"},"aspect_ratio":1.448,"height":411,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke1770SeriesPic1.jpg?v=1634238100","width":595}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eAutomatic measurements. More flexibility. Better power quality troubleshooting.\u003c\/h3\u003e\n\u003cp\u003eReplacing the long standing Fluke 430 Series, the Fluke 1770 Series Three-Phase Power Quality Analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series offers automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord\u003c\/p\u003e\n\u003cp\u003eWith the 1770 Series you’ll never miss a critical power quality event—from fast transients up to 8 kV, harmonics up to 30 kHz, dips and swells, as well as the voltage, current, and power measurements that enable you to characterize your electrical system.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2\u003eAutomatic Measurement capture\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cdiv class=\"container-flex col-reverse\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eWhether you’re performing a quick system check or a detailed power quality study, consistent data is key. The Fluke 1770 Series offers a unique automatic measurement capture system that helps ensure you’re collecting the right data every time, while still giving you the flexibility to select and adjust specific parameters as needed. More than 500 power quality parameters are captured by default and the guided setup makes it easy to select the right parameters for the system you’re working on. Logged data is instantly viewable, downloadable, and shareable with Fluke Energy Analyze Plus software so you never need to wait to finish a session before reviewing results or analyzing data.\u003c\/p\u003e\n\u003ch3\u003eUltimate measurement confidence\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1770 Series are 2-in-1 devices that combine the troubleshooting functionality of a power quality meter with the robust analysis and logging capabilities of a standalone power quality analyzer—in a single, easy-to-use, handheld device.\u003c\/p\u003e\n\u003cp\u003eThe ‘PQ Meter’ function gives you immediate access to live onscreen data in the field so you can quickly identify potential problems while troubleshooting. The detailed ‘PQ Logging and Analysis’ function eliminates the complexity of performing power quality studies by guiding you through the setup process ensuring you’re capturing the right data every time. Couple these measurement modes with a unique measurement connection autocorrect function and you can be confident that you never need to worry about going back for a second measurement—even if you were unsure about what to look for when you started.\u003c\/p\u003e\n\u003ch3\u003eHigh-speed voltage transient capture\u003c\/h3\u003e\n\u003cp\u003eTransients negatively impact otherwise healthy systems every day and their potential to damage your equipment can’t be underestimated. Whether your system is experiencing impulsive or oscillatory transients, the results can be devastating and cause problems ranging from insulation failures to total equipment failures. The Fluke 1775 and Fluke 1777 incorporate advanced transient capture technology to help you clearly identify high-speed voltage transients, so you have the data you need to stop them in their tracks. The Fluke 1775 Power Quality Analyzer has 1MHz sampling capability to capture fast transients, while the Fluke 1777 Power Quality Analyzer has 20MHz sampling capability to capture the fastest transients in high detail.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\" itemprop=\"name\"\u003e\u003cstrong\u003eFluke 1773 Three-Phase Power Quality Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1773 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eI17XX-FLEX1500 24 iFLEX 1500A 24 IN (2.0M) current probes (set of four)\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clips (set of four)\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1M USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cords (US, EU, UK, AUS, BRA)\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eFLUKE-177X-4204, WI-FI\/BLE module\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cstrong\u003eFluke 1775 Three-Phase Power Quality Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1775 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eI17XX-FLEX1500 24 iFLEX 1500A 24 IN (2.0M) current probes (set of four)\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clips (set of four)\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1m USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cord\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eMP1-3R\/1B Magnet Probe set\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-HANGER magnetic hanging kit\u003c\/li\u003e\n\u003cli\u003eFLUKE-177X-4204, WI-FI\/BLE module\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003cli\u003eBlack soft case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cstrong\u003eFluke 1777\u003cspan\u003e \u003c\/span\u003eThree-Phase Power Quality Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1775 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eI17XX-FLEX1500 24 iFLEX 1500A 24 IN (2.0M) current probes (set of four)\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clips (set of four)\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1m USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cord\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eMP1-3R\/1B Magnet Probe set\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-HANGER magnetic hanging kit\u003c\/li\u003e\n\u003cli\u003eFLUKE-177X-4204, WI-FI\/BLE module\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003cli\u003eBlack soft case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1770_Series_Power_Quality_Analyzer_Datasheet.pdf?v=1636404123\" target=\"_blank\" title=\"Fluke 1770 Series Power Quality Datasheet\" rel=\"noopener noreferrer\"\u003eFluke 1770 Series Power Quality Datasheet\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e"}
Fluke 1770 Series Three-Phase Power Quality Analyzers

Fluke 1770 Series Three-Phase Power Quality Analyzers

$11,527.35 CAD

Automatic measurements. More flexibility. Better power quality troubleshooting. Replacing the long standing Fluke 430 Series, the Fluke 1770 Series Three-Phase Power Quality Analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1...


More Info
Fluke 190 Series III ScopeMeters®

Oscilloscopes

From $6,195.00 CAD
{"id":6985633988798,"title":"Fluke 190 Series III ScopeMeters®","handle":"fluke-190-series-iii-scopemeters®","description":"\u003cp\u003eFluke 190 Series III ScopeMeter® Test Tools are engineered to go where you go, and tackle just about any troubleshooting job along the way. These CAT III 1000 V\/CAT IV 600V rated test tools combine rugged portability with the high performance of bench oscilloscopes to help you take on the challenges of installing, commissioning and maintaining industrial machinery, automation and process controls, and power conversion electronics with ease—from DC to 500 MHz.\u003c\/p\u003e\n\u003cp\u003eChoose from two or four channel models with a wide range of bandwidth options. Fast sampling rates up to 5.0 GS\/s, 200 ps resolution and deep memory of 10,000 samples per channel allow high-accuracy capture and display of waveform details, noise, and other disturbances.\u003c\/p\u003e\n\u003cp\u003ePerform timing or amplitude related measurements on three phases or three-axis control systems, or simply compare and contrast multiple test points in a circuit under test. Features like TrendPlot™ Paperless Recorder, ScopeRecord™ Mode, Connect-and-View™ Triggering and a unique 100-screen Replay function help you quickly diagnose issues to minimize repair costs and downtime. These features make the oscilloscopes easy to use especially when diagnosing the most difficult problems like complex waveforms, induced noise, intermittent events and signal fluctuations or drift.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUp to four independent floating isolated inputs, up to 1000 V\u003c\/li\u003e\n\u003cli\u003eUp to 5 GS\/s real time sampling (depending on model and channels used)\u003c\/li\u003e\n\u003cli\u003eDeep memory: 10,000 points per trace waveform capture (scope mode)\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V\/CAT IV 600 V safety rated instrument for industrial environments\u003c\/li\u003e\n\u003cli\u003eUp to seven hours of battery operation using BP291\u003c\/li\u003e\n\u003cli\u003eLarge, bright color display is easy to view in nearly any environment\u003c\/li\u003e\n\u003cli\u003eEasy to store and view historical data and transfer to a PC via USB or Wifi\u003c\/li\u003e\n\u003cli\u003eConvenient battery access door for quick battery swaps in the field\u003c\/li\u003e\n\u003cli\u003eIP51 rating, dust and drip-proof\u003c\/li\u003e\n\u003cli\u003eConnect-and-View triggering for intelligent, automatic triggering on fast, slow and even complex signals\u003c\/li\u003e\n\u003cli\u003eFrequency spectrum using FFT-analysis\u003c\/li\u003e\n\u003cli\u003eAutomatic capture and REPLAY of 100 screens\u003c\/li\u003e\n\u003cli\u003eScopeRecord mode gives 30,000 points per input channel for low frequency signal analysis\u003c\/li\u003e\n\u003cli\u003eTrendPlot Paperless Recorder mode with deep memory for long- term automatic measurements\u003c\/li\u003e\n\u003cli\u003e5,000 count DMM included in the 2-channel models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"1149\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd colspan=\"8\"\u003e\u003cstrong\u003eOscilloscope Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd height=\"27\" width=\"253\"\u003e \u003c\/td\u003e\n\u003ctd width=\"128\"\u003e190-062\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e190-102\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e190-202\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e190-502\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e190-104\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e190-204\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e190-504\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd colspan=\"8\" height=\"19\" width=\"1149\"\u003e\u003cstrong\u003eVertical deflection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eNumber of channels\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e2\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e2\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e2\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e2\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e4\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e4\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eBandwidth\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e60 MHz\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e100 MHz\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e200 MHz\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e500 MHz\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e100 MHz\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e200 MHz\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eRise time\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e5.8 ns\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e3.5 ns\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e1.7 ns\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e0.7 ns\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e3.5 ns\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e1.7 ns\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e0.7 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eNumber of scope inputs\u003c\/td\u003e\n\u003ctd colspan=\"4\" width=\"512\"\u003e2 input channels plus external trigger\u003c\/td\u003e\n\u003ctd colspan=\"3\" width=\"384\"\u003e4 input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eChannel architecture\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003eAll inputs fully insulated from each other and from ground. Inputs may be activated in any combination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eInput coupling\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003eAC or DC, with ground level indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"44\"\u003e\n\u003ctd height=\"44\" width=\"253\"\u003eInput sensitivity\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003eWith 10:1  probe, 20 mV  to 1000 V\/div\u003cbr\u003eWith 100:1  probe, 200 mV to 10 kV\/div\u003cbr\u003eDirect (1:1),  2 mV  to 100 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eBandwidth limiter\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003e20 MHz and 10  kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003ePolarity\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003eNormal,  Inverted, Variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eInput voltage\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003eCAT III 1000 V\/CAT IV 600 V rated, see General specifications for further details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eVertical resolution\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003e8 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"25\"\u003e\n\u003ctd height=\"44\" rowspan=\"2\" width=\"253\"\u003eAccuracy at 4 s to 10 μs\/div\u003c\/td\u003e\n\u003ctd colspan=\"7\" rowspan=\"2\" width=\"896\"\u003e5 mV\/div to 100 V\/div, ±(1.5 % + 6 counts)\u003cbr\u003e2 mV\/div, ±(1.5  % + 10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003e1 MΩ (± 1 %) \/\/  15  pF (± 2.25  pF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd colspan=\"8\" height=\"19\" width=\"1149\"\u003e\u003cstrong\u003eHorizontal\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"45\"\u003e\n\u003ctd height=\"83\" rowspan=\"3\" width=\"253\"\u003eMaximum real- time sample rate (sampled simultaneously)\u003c\/td\u003e\n\u003ctd rowspan=\"3\" width=\"128\"\u003e625 MS\/s\u003cbr\u003e(each channel)\u003c\/td\u003e\n\u003ctd rowspan=\"3\" width=\"128\"\u003e1.25 GS\/s (each channel)\u003c\/td\u003e\n\u003ctd rowspan=\"3\" width=\"128\"\u003e2.5 GS\/s (each channel)\u003c\/td\u003e\n\u003ctd rowspan=\"3\" width=\"128\"\u003e5 GS\/s (single channel) or\u003cbr\u003e2.5 GS\/s (dual channel)\u003c\/td\u003e\n\u003ctd rowspan=\"3\" width=\"128\"\u003e1.25 GS\/s (each channel)\u003c\/td\u003e\n\u003ctd rowspan=\"3\" width=\"128\"\u003e2.5 GS\/s (2ch)\u003cbr\u003e1.25 GS\/s (4ch)\u003c\/td\u003e\n\u003ctd rowspan=\"3\" width=\"128\"\u003e5 GS\/s (single ch) or 2.5 GS\/s (2ch) or 1.25 GS\/s (4ch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eRecord length\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003eUp to 10,000 samples per  channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"78\" rowspan=\"4\" width=\"253\"\u003eTime base range\u003c\/td\u003e\n\u003ctd rowspan=\"2\" width=\"128\"\u003e10 ns\/div\u003cbr\u003eto 4 s\/div\u003c\/td\u003e\n\u003ctd rowspan=\"2\" width=\"128\"\u003e5 ns\/div\u003cbr\u003eto 4 s\/div\u003c\/td\u003e\n\u003ctd rowspan=\"2\" width=\"128\"\u003e2 ns\/div\u003cbr\u003eto 4 s\/div\u003c\/td\u003e\n\u003ctd rowspan=\"2\" width=\"128\"\u003e1 ns\/div\u003cbr\u003eto 4 s\/div\u003c\/td\u003e\n\u003ctd rowspan=\"2\" width=\"128\"\u003e5 ns\/div\u003cbr\u003eto 4 s\/div\u003c\/td\u003e\n\u003ctd rowspan=\"2\" width=\"128\"\u003e2 ns\/div\u003cbr\u003eto 4 s\/div\u003c\/td\u003e\n\u003ctd rowspan=\"2\" width=\"128\"\u003e1 ns\/div\u003cbr\u003eto 4 s\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd colspan=\"7\" height=\"40\" rowspan=\"2\" width=\"896\"\u003eTime base in a 1-2-4-sequence\u003cbr\u003eSlower time\/division settings using ScopeRecord™ Roll mode (see ‘Recorder mode’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr height=\"25\"\u003e\n\u003ctd height=\"45\" rowspan=\"2\" width=\"253\"\u003eMaximum record length\u003c\/td\u003e\n\u003ctd colspan=\"7\" rowspan=\"2\" width=\"896\"\u003e10,000 samples per channel in scope mode\u003cbr\u003e30,000 points per channel in ScopeRecord™ Roll mode (see ‘Recorder mode’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eTiming accuracy\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003e± (0.01 % of reading + 1  pixel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eGlitch capture\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003e8 ns (10  µs\/div to 2 min\/div)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eScopeMeter Test Tool\u003c\/li\u003e\n\u003cli\u003eBC190\/830 power adapter\u003c\/li\u003e\n\u003cli\u003ePower cord set\u003c\/li\u003e\n\u003cli\u003eBP291 Li-ion battery pack\u003c\/li\u003e\n\u003cli\u003e** VPS410-II probe (4x)\u003c\/li\u003e\n\u003cli\u003eHand strap\u003c\/li\u003e\n\u003cli\u003eHanging strap\u003c\/li\u003e\n\u003cli\u003eUSB-cable\u003c\/li\u003e\n\u003cli\u003e** TRM50 cable terminator (4 pcs)\u003c\/li\u003e\n\u003cli\u003e** CXT293 carrying case (Kit Only)\u003c\/li\u003e\n\u003cli\u003e** DWA-131 WiFi dongle\u003c\/li\u003e\n\u003cli\u003e** FlukeView Activation Software (Kit Only)\u003c\/li\u003e\n\u003cli\u003ePrinted instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e**Included items vary based on model selected\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e","published_at":"2021-09-27T12:14:00-06:00","created_at":"2021-09-27T12:14:00-06:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":619500,"price_min":619500,"price_max":1043799,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":40724993573054,"title":"190-102-III, 2CH 100MHz","option1":"190-102-III, 2CH 100MHz","option2":null,"option3":null,"sku":"FLU-190-102-III","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190 Series III ScopeMeters® - 190-102-III, 2CH 100MHz","public_title":"190-102-III, 2CH 100MHz","options":["190-102-III, 2CH 100MHz"],"price":670343,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"195112021798","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":40724993605822,"title":"190-102-III-S, 2CH 100MHz with Kit","option1":"190-102-III-S, 2CH 100MHz with Kit","option2":null,"option3":null,"sku":"FLU-190-102-III-S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190 Series III ScopeMeters® - 190-102-III-S, 2CH 100MHz with Kit","public_title":"190-102-III-S, 2CH 100MHz with Kit","options":["190-102-III-S, 2CH 100MHz with Kit"],"price":739023,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"195112021804","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":40724993638590,"title":"190-104-III, 4CH 100MHz","option1":"190-104-III, 4CH 100MHz","option2":null,"option3":null,"sku":"FLU-190-104-III","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190 Series III ScopeMeters® - 190-104-III, 4CH 100MHz","public_title":"190-104-III, 4CH 100MHz","options":["190-104-III, 4CH 100MHz"],"price":754255,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"195112021828","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":40724993671358,"title":"190-104-III-S, 4CH 100MHz with Kit","option1":"190-104-III-S, 4CH 100MHz with Kit","option2":null,"option3":null,"sku":"FLU-190-104-III-S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190 Series III ScopeMeters® - 190-104-III-S, 4CH 100MHz with Kit","public_title":"190-104-III-S, 4CH 100MHz with Kit","options":["190-104-III-S, 4CH 100MHz with Kit"],"price":822799,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"195112021835","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":40724993704126,"title":"190-202-III, 2CH 200MHz","option1":"190-202-III, 2CH 200MHz","option2":null,"option3":null,"sku":"FLU-190-202-III","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190 Series III ScopeMeters® - 190-202-III, 2CH 200MHz","public_title":"190-202-III, 2CH 200MHz","options":["190-202-III, 2CH 200MHz"],"price":619500,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"195112021842","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":40724993736894,"title":"190-202-III-S, 2CH 200MHz with Kit","option1":"190-202-III-S, 2CH 200MHz with Kit","option2":null,"option3":null,"sku":"FLU-190-202-III-S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190 Series III ScopeMeters® - 190-202-III-S, 2CH 200MHz with Kit","public_title":"190-202-III-S, 2CH 200MHz with Kit","options":["190-202-III-S, 2CH 200MHz with Kit"],"price":792335,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"195112021859","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":40724993769662,"title":"190-204-III, 4CH 200MHz","option1":"190-204-III, 4CH 200MHz","option2":null,"option3":null,"sku":"FLU-190-204-III","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190 Series III ScopeMeters® - 190-204-III, 4CH 200MHz","public_title":"190-204-III, 4CH 200MHz","options":["190-204-III, 4CH 200MHz"],"price":861015,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"195112021866","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":40724993802430,"title":"190-204-III-S, 4CH 200MHz with Kit","option1":"190-204-III-S, 4CH 200MHz with Kit","option2":null,"option3":null,"sku":"FLU-190-204-III-S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190 Series III ScopeMeters® - 190-204-III-S, 4CH 200MHz with Kit","public_title":"190-204-III-S, 4CH 200MHz with Kit","options":["190-204-III-S, 4CH 200MHz with Kit"],"price":921807,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"195112021873","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":40724993867966,"title":"190-502-III, 2CH 500MHz","option1":"190-502-III, 2CH 500MHz","option2":null,"option3":null,"sku":"FLU-190-502-III","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190 Series III ScopeMeters® - 190-502-III, 2CH 500MHz","public_title":"190-502-III, 2CH 500MHz","options":["190-502-III, 2CH 500MHz"],"price":816500,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"195112021880","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":40724993900734,"title":"190-502-III-S, 2CH 500MHz with Kit","option1":"190-502-III-S, 2CH 500MHz with Kit","option2":null,"option3":null,"sku":"FLU-190-502-III-S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190 Series III ScopeMeters® - 190-502-III-S, 2CH 500MHz with Kit","public_title":"190-502-III-S, 2CH 500MHz with Kit","options":["190-502-III-S, 2CH 500MHz with Kit"],"price":1036183,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"195112021897","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":40724993933502,"title":"190-504-III, 4CH 500MHz","option1":"190-504-III, 4CH 500MHz","option2":null,"option3":null,"sku":"FLU-190-504-III","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190 Series III ScopeMeters® - 190-504-III, 4CH 500MHz","public_title":"190-504-III, 4CH 500MHz","options":["190-504-III, 4CH 500MHz"],"price":975119,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"195112021903","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":40724993966270,"title":"190-504-III-S, 4CH 500MHz with Kit","option1":"190-504-III-S, 4CH 500MHz with Kit","option2":null,"option3":null,"sku":"FLU-190-504-III-S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190 Series III ScopeMeters® - 190-504-III-S, 4CH 500MHz with Kit","public_title":"190-504-III-S, 4CH 500MHz with Kit","options":["190-504-III-S, 4CH 500MHz with Kit"],"price":1043799,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"195112021910","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke190SeriesIIIScopeMeterPic2.jpg?v=1632767250","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke190SeriesIIIScopeMeterPic3.jpg?v=1632767175"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke190SeriesIIIScopeMeterPic2.jpg?v=1632767250","options":["Model"],"media":[{"alt":null,"id":22277932843198,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke190SeriesIIIScopeMeterPic2.jpg?v=1632767250"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke190SeriesIIIScopeMeterPic2.jpg?v=1632767250","width":1024},{"alt":null,"id":22277923078334,"position":2,"preview_image":{"aspect_ratio":1.5,"height":410,"width":615,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke190SeriesIIIScopeMeterPic3.jpg?v=1632767175"},"aspect_ratio":1.5,"height":410,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke190SeriesIIIScopeMeterPic3.jpg?v=1632767175","width":615}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eFluke 190 Series III ScopeMeter® Test Tools are engineered to go where you go, and tackle just about any troubleshooting job along the way. These CAT III 1000 V\/CAT IV 600V rated test tools combine rugged portability with the high performance of bench oscilloscopes to help you take on the challenges of installing, commissioning and maintaining industrial machinery, automation and process controls, and power conversion electronics with ease—from DC to 500 MHz.\u003c\/p\u003e\n\u003cp\u003eChoose from two or four channel models with a wide range of bandwidth options. Fast sampling rates up to 5.0 GS\/s, 200 ps resolution and deep memory of 10,000 samples per channel allow high-accuracy capture and display of waveform details, noise, and other disturbances.\u003c\/p\u003e\n\u003cp\u003ePerform timing or amplitude related measurements on three phases or three-axis control systems, or simply compare and contrast multiple test points in a circuit under test. Features like TrendPlot™ Paperless Recorder, ScopeRecord™ Mode, Connect-and-View™ Triggering and a unique 100-screen Replay function help you quickly diagnose issues to minimize repair costs and downtime. These features make the oscilloscopes easy to use especially when diagnosing the most difficult problems like complex waveforms, induced noise, intermittent events and signal fluctuations or drift.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUp to four independent floating isolated inputs, up to 1000 V\u003c\/li\u003e\n\u003cli\u003eUp to 5 GS\/s real time sampling (depending on model and channels used)\u003c\/li\u003e\n\u003cli\u003eDeep memory: 10,000 points per trace waveform capture (scope mode)\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V\/CAT IV 600 V safety rated instrument for industrial environments\u003c\/li\u003e\n\u003cli\u003eUp to seven hours of battery operation using BP291\u003c\/li\u003e\n\u003cli\u003eLarge, bright color display is easy to view in nearly any environment\u003c\/li\u003e\n\u003cli\u003eEasy to store and view historical data and transfer to a PC via USB or Wifi\u003c\/li\u003e\n\u003cli\u003eConvenient battery access door for quick battery swaps in the field\u003c\/li\u003e\n\u003cli\u003eIP51 rating, dust and drip-proof\u003c\/li\u003e\n\u003cli\u003eConnect-and-View triggering for intelligent, automatic triggering on fast, slow and even complex signals\u003c\/li\u003e\n\u003cli\u003eFrequency spectrum using FFT-analysis\u003c\/li\u003e\n\u003cli\u003eAutomatic capture and REPLAY of 100 screens\u003c\/li\u003e\n\u003cli\u003eScopeRecord mode gives 30,000 points per input channel for low frequency signal analysis\u003c\/li\u003e\n\u003cli\u003eTrendPlot Paperless Recorder mode with deep memory for long- term automatic measurements\u003c\/li\u003e\n\u003cli\u003e5,000 count DMM included in the 2-channel models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"1149\"\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd colspan=\"8\"\u003e\u003cstrong\u003eOscilloscope Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"27\"\u003e\n\u003ctd height=\"27\" width=\"253\"\u003e \u003c\/td\u003e\n\u003ctd width=\"128\"\u003e190-062\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e190-102\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e190-202\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e190-502\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e190-104\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e190-204\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e190-504\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd colspan=\"8\" height=\"19\" width=\"1149\"\u003e\u003cstrong\u003eVertical deflection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eNumber of channels\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e2\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e2\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e2\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e2\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e4\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e4\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eBandwidth\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e60 MHz\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e100 MHz\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e200 MHz\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e500 MHz\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e100 MHz\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e200 MHz\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e500 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eRise time\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e5.8 ns\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e3.5 ns\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e1.7 ns\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e0.7 ns\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e3.5 ns\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e1.7 ns\u003c\/td\u003e\n\u003ctd width=\"128\"\u003e0.7 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eNumber of scope inputs\u003c\/td\u003e\n\u003ctd colspan=\"4\" width=\"512\"\u003e2 input channels plus external trigger\u003c\/td\u003e\n\u003ctd colspan=\"3\" width=\"384\"\u003e4 input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eChannel architecture\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003eAll inputs fully insulated from each other and from ground. Inputs may be activated in any combination.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eInput coupling\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003eAC or DC, with ground level indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"44\"\u003e\n\u003ctd height=\"44\" width=\"253\"\u003eInput sensitivity\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003eWith 10:1  probe, 20 mV  to 1000 V\/div\u003cbr\u003eWith 100:1  probe, 200 mV to 10 kV\/div\u003cbr\u003eDirect (1:1),  2 mV  to 100 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eBandwidth limiter\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003e20 MHz and 10  kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003ePolarity\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003eNormal,  Inverted, Variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eInput voltage\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003eCAT III 1000 V\/CAT IV 600 V rated, see General specifications for further details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eVertical resolution\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003e8 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"25\"\u003e\n\u003ctd height=\"44\" rowspan=\"2\" width=\"253\"\u003eAccuracy at 4 s to 10 μs\/div\u003c\/td\u003e\n\u003ctd colspan=\"7\" rowspan=\"2\" width=\"896\"\u003e5 mV\/div to 100 V\/div, ±(1.5 % + 6 counts)\u003cbr\u003e2 mV\/div, ±(1.5  % + 10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003e1 MΩ (± 1 %) \/\/  15  pF (± 2.25  pF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd colspan=\"8\" height=\"19\" width=\"1149\"\u003e\u003cstrong\u003eHorizontal\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"45\"\u003e\n\u003ctd height=\"83\" rowspan=\"3\" width=\"253\"\u003eMaximum real- time sample rate (sampled simultaneously)\u003c\/td\u003e\n\u003ctd rowspan=\"3\" width=\"128\"\u003e625 MS\/s\u003cbr\u003e(each channel)\u003c\/td\u003e\n\u003ctd rowspan=\"3\" width=\"128\"\u003e1.25 GS\/s (each channel)\u003c\/td\u003e\n\u003ctd rowspan=\"3\" width=\"128\"\u003e2.5 GS\/s (each channel)\u003c\/td\u003e\n\u003ctd rowspan=\"3\" width=\"128\"\u003e5 GS\/s (single channel) or\u003cbr\u003e2.5 GS\/s (dual channel)\u003c\/td\u003e\n\u003ctd rowspan=\"3\" width=\"128\"\u003e1.25 GS\/s (each channel)\u003c\/td\u003e\n\u003ctd rowspan=\"3\" width=\"128\"\u003e2.5 GS\/s (2ch)\u003cbr\u003e1.25 GS\/s (4ch)\u003c\/td\u003e\n\u003ctd rowspan=\"3\" width=\"128\"\u003e5 GS\/s (single ch) or 2.5 GS\/s (2ch) or 1.25 GS\/s (4ch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eRecord length\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003eUp to 10,000 samples per  channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"78\" rowspan=\"4\" width=\"253\"\u003eTime base range\u003c\/td\u003e\n\u003ctd rowspan=\"2\" width=\"128\"\u003e10 ns\/div\u003cbr\u003eto 4 s\/div\u003c\/td\u003e\n\u003ctd rowspan=\"2\" width=\"128\"\u003e5 ns\/div\u003cbr\u003eto 4 s\/div\u003c\/td\u003e\n\u003ctd rowspan=\"2\" width=\"128\"\u003e2 ns\/div\u003cbr\u003eto 4 s\/div\u003c\/td\u003e\n\u003ctd rowspan=\"2\" width=\"128\"\u003e1 ns\/div\u003cbr\u003eto 4 s\/div\u003c\/td\u003e\n\u003ctd rowspan=\"2\" width=\"128\"\u003e5 ns\/div\u003cbr\u003eto 4 s\/div\u003c\/td\u003e\n\u003ctd rowspan=\"2\" width=\"128\"\u003e2 ns\/div\u003cbr\u003eto 4 s\/div\u003c\/td\u003e\n\u003ctd rowspan=\"2\" width=\"128\"\u003e1 ns\/div\u003cbr\u003eto 4 s\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\n\u003ctd colspan=\"7\" height=\"40\" rowspan=\"2\" width=\"896\"\u003eTime base in a 1-2-4-sequence\u003cbr\u003eSlower time\/division settings using ScopeRecord™ Roll mode (see ‘Recorder mode’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr height=\"25\"\u003e\n\u003ctd height=\"45\" rowspan=\"2\" width=\"253\"\u003eMaximum record length\u003c\/td\u003e\n\u003ctd colspan=\"7\" rowspan=\"2\" width=\"896\"\u003e10,000 samples per channel in scope mode\u003cbr\u003e30,000 points per channel in ScopeRecord™ Roll mode (see ‘Recorder mode’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eTiming accuracy\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003e± (0.01 % of reading + 1  pixel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\"\u003e\n\u003ctd height=\"19\" width=\"253\"\u003eGlitch capture\u003c\/td\u003e\n\u003ctd colspan=\"7\" width=\"896\"\u003e8 ns (10  µs\/div to 2 min\/div)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eScopeMeter Test Tool\u003c\/li\u003e\n\u003cli\u003eBC190\/830 power adapter\u003c\/li\u003e\n\u003cli\u003ePower cord set\u003c\/li\u003e\n\u003cli\u003eBP291 Li-ion battery pack\u003c\/li\u003e\n\u003cli\u003e** VPS410-II probe (4x)\u003c\/li\u003e\n\u003cli\u003eHand strap\u003c\/li\u003e\n\u003cli\u003eHanging strap\u003c\/li\u003e\n\u003cli\u003eUSB-cable\u003c\/li\u003e\n\u003cli\u003e** TRM50 cable terminator (4 pcs)\u003c\/li\u003e\n\u003cli\u003e** CXT293 carrying case (Kit Only)\u003c\/li\u003e\n\u003cli\u003e** DWA-131 WiFi dongle\u003c\/li\u003e\n\u003cli\u003e** FlukeView Activation Software (Kit Only)\u003c\/li\u003e\n\u003cli\u003ePrinted instructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e**Included items vary based on model selected\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e"}
Fluke 190 Series III ScopeMeters®

Fluke 190 Series III ScopeMeters®

$10,437.99 CAD

Fluke 190 Series III ScopeMeter® Test Tools are engineered to go where you go, and tackle just about any troubleshooting job along the way. These CAT III 1000 V/CAT IV 600V rated test tools combine rugged portability with the high performance of bench oscilloscopes to help you take on the challenges of installing, commissioning and maintaining i...


More Info
{"id":6939402567870,"title":"Fluke 393 FC CAT III True RMS Wireless Clamp Meter with iFlex, 1500 V","handle":"fluke-393-fc-cat-iii-true-rms-wireless-clamp-meter-with-iflex-1500-v","description":"\u003cp\u003e\u003cspan\u003eSafely and accurately measure up to 1500 V in DC environments with this rugged CAT III True-RMS Clamp Meter. IP54-rated and with a narrow jaw design, this meter is ideal for tight spaces and provides access to cables in crowded combiner boxes. The included iFlex current probe extends AC measurements up to 2500 A.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is designed for technicians who work in high voltage dc environment: solar arrays, wind power, electric railways, data centers battery banks for uninterruptible power supplies. The clamp will measure up to 1500 V dc, 1000 V ac, and up to 999.9 A dc or ac through the clamp jaw.  The included iFlex flexible current probe extended ac current measurements up to 2500 amps.This clamp has a thin jaw, giving you access to cables in crowded combiner boxes. Test leads are designed with your work in mind, and are also rated to CAT III 1500 V dc.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cspan\u003eOther key functions:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIP54 rated, ideal for work outdoors on solar arrays and wind power systems \u003c\/li\u003e\n\u003cli\u003eDC power measurement, showing readings in kVA\u003c\/li\u003e\n\u003cli\u003eAudio Polarity indicator helps prevent accidental miswires\u003c\/li\u003e\n\u003cli\u003eVisual Continuity turns provide a bright green light in the display, ideal when working in dark and noisy environments\u003c\/li\u003e\n\u003cli\u003eLogging and reporting of test results via Fluke Connect software\u003c\/li\u003e\n\u003cli\u003eWhen measuring ac current the included iFlex flexible current probe gives you unparalleled access to cable is tight spaces.  The iFlex probe can be twisted through extremely small spaces and provide accurate current measurements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAC Current Jaw\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% + 5 digits (10 to 100 Hz)\u003cbr\u003e2.5% + 5 digits (100 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd\u003e2.5 at 600 A\u003cbr\u003e3 at 500 A\u003cbr\u003e1.42 at 999.9 A\u003cbr\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFlexible Current Probe AC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003cbr\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A (≤999.9 A) 1 A (≤2500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e3% RD + 5 digits (10 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd\u003e2.5 at 1400 A\u003cbr\u003e3 at 1100 A\u003cbr\u003e1.42 at 2500 A\u003cbr\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% RD + 5 digits (when using the ZERO function to compensate for offsets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600 V\u003cbr\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V (≤600 V)\u003cbr\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits (20 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600 V\u003cbr\u003e1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V (≤600 V)\u003cbr\u003e1 V (≤1500 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003emV DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e500 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eJaw Amps Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd\u003e5 to 10 Hz, ≥10 A\u003cbr\u003e10 to 100 Hz, ≥5 A\u003cbr\u003e100 to 500 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFlexible Current Probe Amps Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd\u003e5 to 20 Hz, ≥25 A\u003cbr\u003e20 to 100 Hz, ≥20 A\u003cbr\u003e100 to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVoltage Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd\u003e5 to 20 Hz, ≥5 V\u003cbr\u003e20 to 100 Hz, ≥5 V\u003cbr\u003e100 to 500 Hz, ≥10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600 kVA (600 V DC range)\u003cbr\u003e1500 kVA (1500 V DC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 kVA\u003cbr\u003e1 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% RD + 2 KVA\u003cbr\u003e2% RD + 20 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600 Ω\u003cbr\u003e6000 Ω\u003cbr\u003e60 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω (≤600 Ω)\u003cbr\u003e1 Ω (≤6000 Ω)\u003cbr\u003e0.01 kΩ (≤60.00 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e100.0 μF\u003cbr\u003e1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 μF (≤100.0 μF)\u003cbr\u003e1 μF (≤1000 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Trigger Level\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eOperating: 14 to 122°F (-10 to 50°C)\u003cbr\u003eStorage: -40 to 140°F (-40 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003eNon-condensing (\u0026lt;10°C)\u003cbr\u003e≤90% RH at 50 to 86°F (10 to 30°C)\u003cbr\u003e≤75% RH at 86 to 104°F (30 to 40°C)\u003cbr\u003e≤45% RH at 104 to 122°F (40 to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating: 6562' (2000 m)\u003cbr\u003eStorage: 39370' (12000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage (Between Terminal and Earth Ground)\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003cbr\u003e1500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd\u003e2 AA IEC LR6 alkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDual display with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic power off\u003c\/td\u003e\n\u003ctd\u003e20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd\u003e1.3 \" (34 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe Diameter\u003c\/td\u003e\n\u003ctd\u003e0.29\" (7.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe Cable Length\u003c\/td\u003e\n\u003ctd\u003e5.9' (1.8 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11 x 3.3 x 1.9\" (281 x 84 x 49 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eClamp Meter\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003cli\u003eFlexible Current Probe\u003c\/li\u003e\n\u003cli\u003eMagnetic Hanging Strap\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_393.pdf?v=1630614745\" target=\"_blank\" title=\"Fluke 393 FC CAT III True RMS Wireless Clamp Meter with iFlex, 1500V Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 393 FC CAT III True RMS Wireless Clamp Meter with iFlex, 1500 V Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-09-02T14:39:30-06:00","created_at":"2021-09-02T14:39:29-06:00","vendor":"Fluke","type":"Clamp Meters","tags":[],"price":108799,"price_min":108799,"price_max":108799,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":40563976700094,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-393FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 393 FC CAT III True RMS Wireless Clamp Meter with iFlex, 1500 V","public_title":null,"options":["Default Title"],"price":108799,"weight":907,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke-393-FC.jpg?v=1630615170"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke-393-FC.jpg?v=1630615170","options":["Title"],"media":[{"alt":null,"id":22024660877502,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke-393-FC.jpg?v=1630615170"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke-393-FC.jpg?v=1630615170","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eSafely and accurately measure up to 1500 V in DC environments with this rugged CAT III True-RMS Clamp Meter. IP54-rated and with a narrow jaw design, this meter is ideal for tight spaces and provides access to cables in crowded combiner boxes. The included iFlex current probe extends AC measurements up to 2500 A.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is designed for technicians who work in high voltage dc environment: solar arrays, wind power, electric railways, data centers battery banks for uninterruptible power supplies. The clamp will measure up to 1500 V dc, 1000 V ac, and up to 999.9 A dc or ac through the clamp jaw.  The included iFlex flexible current probe extended ac current measurements up to 2500 amps.This clamp has a thin jaw, giving you access to cables in crowded combiner boxes. Test leads are designed with your work in mind, and are also rated to CAT III 1500 V dc.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cspan\u003eOther key functions:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIP54 rated, ideal for work outdoors on solar arrays and wind power systems \u003c\/li\u003e\n\u003cli\u003eDC power measurement, showing readings in kVA\u003c\/li\u003e\n\u003cli\u003eAudio Polarity indicator helps prevent accidental miswires\u003c\/li\u003e\n\u003cli\u003eVisual Continuity turns provide a bright green light in the display, ideal when working in dark and noisy environments\u003c\/li\u003e\n\u003cli\u003eLogging and reporting of test results via Fluke Connect software\u003c\/li\u003e\n\u003cli\u003eWhen measuring ac current the included iFlex flexible current probe gives you unparalleled access to cable is tight spaces.  The iFlex probe can be twisted through extremely small spaces and provide accurate current measurements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAC Current Jaw\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% + 5 digits (10 to 100 Hz)\u003cbr\u003e2.5% + 5 digits (100 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd\u003e2.5 at 600 A\u003cbr\u003e3 at 500 A\u003cbr\u003e1.42 at 999.9 A\u003cbr\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFlexible Current Probe AC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003cbr\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A (≤999.9 A) 1 A (≤2500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e3% RD + 5 digits (10 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd\u003e2.5 at 1400 A\u003cbr\u003e3 at 1100 A\u003cbr\u003e1.42 at 2500 A\u003cbr\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% RD + 5 digits (when using the ZERO function to compensate for offsets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600 V\u003cbr\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V (≤600 V)\u003cbr\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits (20 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600 V\u003cbr\u003e1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V (≤600 V)\u003cbr\u003e1 V (≤1500 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003emV DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e500 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eJaw Amps Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd\u003e5 to 10 Hz, ≥10 A\u003cbr\u003e10 to 100 Hz, ≥5 A\u003cbr\u003e100 to 500 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFlexible Current Probe Amps Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd\u003e5 to 20 Hz, ≥25 A\u003cbr\u003e20 to 100 Hz, ≥20 A\u003cbr\u003e100 to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVoltage Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd\u003e5 to 20 Hz, ≥5 V\u003cbr\u003e20 to 100 Hz, ≥5 V\u003cbr\u003e100 to 500 Hz, ≥10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600 kVA (600 V DC range)\u003cbr\u003e1500 kVA (1500 V DC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 kVA\u003cbr\u003e1 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% RD + 2 KVA\u003cbr\u003e2% RD + 20 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600 Ω\u003cbr\u003e6000 Ω\u003cbr\u003e60 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω (≤600 Ω)\u003cbr\u003e1 Ω (≤6000 Ω)\u003cbr\u003e0.01 kΩ (≤60.00 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e100.0 μF\u003cbr\u003e1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 μF (≤100.0 μF)\u003cbr\u003e1 μF (≤1000 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Trigger Level\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eOperating: 14 to 122°F (-10 to 50°C)\u003cbr\u003eStorage: -40 to 140°F (-40 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003eNon-condensing (\u0026lt;10°C)\u003cbr\u003e≤90% RH at 50 to 86°F (10 to 30°C)\u003cbr\u003e≤75% RH at 86 to 104°F (30 to 40°C)\u003cbr\u003e≤45% RH at 104 to 122°F (40 to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating: 6562' (2000 m)\u003cbr\u003eStorage: 39370' (12000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage (Between Terminal and Earth Ground)\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003cbr\u003e1500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd\u003e2 AA IEC LR6 alkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDual display with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic power off\u003c\/td\u003e\n\u003ctd\u003e20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd\u003e1.3 \" (34 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe Diameter\u003c\/td\u003e\n\u003ctd\u003e0.29\" (7.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe Cable Length\u003c\/td\u003e\n\u003ctd\u003e5.9' (1.8 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11 x 3.3 x 1.9\" (281 x 84 x 49 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eClamp Meter\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003cli\u003eFlexible Current Probe\u003c\/li\u003e\n\u003cli\u003eMagnetic Hanging Strap\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_393.pdf?v=1630614745\" target=\"_blank\" title=\"Fluke 393 FC CAT III True RMS Wireless Clamp Meter with iFlex, 1500V Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 393 FC CAT III True RMS Wireless Clamp Meter with iFlex, 1500 V Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 393 FC CAT III True RMS Wireless Clamp Meter with iFlex, 1500 V

Fluke 393 FC CAT III True RMS Wireless Clamp Meter with iFlex, 1500 V

$1,087.99 CAD

Safely and accurately measure up to 1500 V in DC environments with this rugged CAT III True-RMS Clamp Meter. IP54-rated and with a narrow jaw design, this meter is ideal for tight spaces and provides access to cables in crowded combiner boxes. The included iFlex current probe extends AC measurements up to 2500 A. Overview The 393 FC CAT III 150...


More Info
Fluke ii910 Precision Acoustic Imager

Leak Detection

$38,827.99 CAD
{"id":6828850741438,"title":"Fluke ii910 Precision Acoustic Imager","handle":"fluke-ii910-precision-acoustic-imager","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cspan\u003e*AVAILABLE FOR RENT - Call us for more information*\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFinally, an easy way to detect, locate, and analyze \u003cu\u003eleaks\u003c\/u\u003e and \u003cu\u003epartial discharge \u003c\/u\u003ein one tool. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBuilding on the game changing ii900 that was introduced in the fall of 2019, the Fluke ii910 Precision Acoustic Imager has been engineered with extra precision to locate gas and vacuum leaks up to 120 meters, as well as an extended frequency measurement range of 100kHz which is critical for early detection of Partial Discharge (PD) including Corona and Surface tracking. The ii910 deploys groundbreaking technology that is cost efficient, safe, simple, and comfortable to use. Utilizing an array of 64 strategically located microphones in concert with a built-in visible light camera the Fluke ii910 continuously runs precise algorithms that create Fluke’s live SightSound Image allowing you to locate multiple leaks or PD in real-time, faster than ever before!\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/6xzVwLdnFhE?start=12\" height=\"315\" width=\"560\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eQuick and easy partial discharge detection and PD testing\u003c\/li\u003e\n\u003cli\u003eReduce outages and increase uptime\u003c\/li\u003e\n\u003cli\u003eCut costs and save energy everyday by finding and fixing PD\u003c\/li\u003e\n\u003cli\u003ePDQ Mode to capture and analyze partial discharge\u003c\/li\u003e\n\u003cli\u003eDo more with the same air compressors – delay the capital expense of purchasing an additional compressor\u003c\/li\u003e\n\u003cli\u003eEnsure proper air pressure to your pneumatic equipment\u003c\/li\u003e\n\u003cli\u003eLower utility costs\u003c\/li\u003e\n\u003cli\u003eReduce leak detection time\u003c\/li\u003e\n\u003cli\u003eImprove reliability in your production line\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSensors\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency band\u003c\/td\u003e\n\u003ctd\u003e2 kHz to 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection range\u003c\/td\u003e\n\u003ctd\u003e0.5 to \u0026gt; 120 meters (1.6 to \u0026gt; 393 feet)*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of View\u003c\/td\u003e\n\u003ctd\u003e63 ° ± 5 °\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal frame rate\u003c\/td\u003e\n\u003ctd\u003e25 FPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003csmall\u003e*Depending on ambient conditions\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eBuilt-in digital camera (visible light)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of View (FOV)\u003c\/td\u003e\n\u003ctd\u003e63 ° ± 5 °\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFocus\u003c\/td\u003e\n\u003ctd\u003eFixed lens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eDisplay\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e7\" LCD with backlight, under-sunlight readable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1280 x 800 (1,024,000 pixels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen\u003c\/td\u003e\n\u003ctd\u003eCapacitive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcoustic image\u003c\/td\u003e\n\u003ctd\u003eYes, SoundMap™ image\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eImage storage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage capacity\u003c\/td\u003e\n\u003ctd\u003eInternal memory with the capacity for 999 picture files and 20 video files\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage format\u003c\/td\u003e\n\u003ctd\u003eBlended visual and SoundMap™.JPG or .PNG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVideo format\u003c\/td\u003e\n\u003ctd\u003eBlended visual and SoundMap™.MP4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVideo length\u003c\/td\u003e\n\u003ctd\u003e5 minutes maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital export\u003c\/td\u003e\n\u003ctd\u003eUSB-C for data transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eImager\u003c\/li\u003e\n\u003cli\u003eAC power supply and battery pack charger (including universal AC adapters)\u003c\/li\u003e\n\u003cli\u003eTwo rugged lithium ion smart battery packs\u003c\/li\u003e\n\u003cli\u003eUSB cable\u003c\/li\u003e\n\u003cli\u003eRugged, hard carrying case\u003c\/li\u003e\n\u003cli\u003eAdjustable hand strap and neck strap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca title=\"Fluke ii910 Acoustic Imager Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_ii900-910_Spec_Sheet.pdf?v=1626100077\" target=\"_blank\"\u003eFluke ii910 Acoustic Imager Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-07-12T08:15:47-06:00","created_at":"2021-07-12T08:15:47-06:00","vendor":"Fluke","type":"Leak Detection","tags":[],"price":3882799,"price_min":3882799,"price_max":3882799,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":40161653194942,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-ii910","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke ii910 Precision Acoustic Imager","public_title":null,"options":["Default Title"],"price":3882799,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"195112008164","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-ii910_01a_c.jpg?v=1626099912","\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-ii910_04a_c.jpg?v=1626099912","\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-ii910_21a_c.jpg?v=1626099930","\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-ii910_08a_c.jpg?v=1626099946"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-ii910_01a_c.jpg?v=1626099912","options":["Title"],"media":[{"alt":null,"id":21494058221758,"position":1,"preview_image":{"aspect_ratio":1.643,"height":913,"width":1500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-ii910_01a_c.jpg?v=1626099912"},"aspect_ratio":1.643,"height":913,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-ii910_01a_c.jpg?v=1626099912","width":1500},{"alt":null,"id":21494058483902,"position":2,"preview_image":{"aspect_ratio":1.391,"height":1078,"width":1500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-ii910_04a_c.jpg?v=1626099912"},"aspect_ratio":1.391,"height":1078,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-ii910_04a_c.jpg?v=1626099912","width":1500},{"alt":null,"id":21494060220606,"position":3,"preview_image":{"aspect_ratio":1.5,"height":1000,"width":1500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-ii910_21a_c.jpg?v=1626099930"},"aspect_ratio":1.5,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-ii910_21a_c.jpg?v=1626099930","width":1500},{"alt":null,"id":21494061007038,"position":4,"preview_image":{"aspect_ratio":1.5,"height":1000,"width":1500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-ii910_08a_c.jpg?v=1626099946"},"aspect_ratio":1.5,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-ii910_08a_c.jpg?v=1626099946","width":1500},{"alt":null,"id":21494103179454,"position":5,"preview_image":{"aspect_ratio":1.333,"height":360,"width":480,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/hqdefault_27e05130-e1a5-4f2a-be5f-710f9191f08c.jpg?v=1626100237"},"aspect_ratio":1.77,"external_id":"6xzVwLdnFhE","host":"youtube","media_type":"external_video"}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2 style=\"text-align: center;\"\u003e\u003cspan\u003e*AVAILABLE FOR RENT - Call us for more information*\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFinally, an easy way to detect, locate, and analyze \u003cu\u003eleaks\u003c\/u\u003e and \u003cu\u003epartial discharge \u003c\/u\u003ein one tool. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBuilding on the game changing ii900 that was introduced in the fall of 2019, the Fluke ii910 Precision Acoustic Imager has been engineered with extra precision to locate gas and vacuum leaks up to 120 meters, as well as an extended frequency measurement range of 100kHz which is critical for early detection of Partial Discharge (PD) including Corona and Surface tracking. The ii910 deploys groundbreaking technology that is cost efficient, safe, simple, and comfortable to use. Utilizing an array of 64 strategically located microphones in concert with a built-in visible light camera the Fluke ii910 continuously runs precise algorithms that create Fluke’s live SightSound Image allowing you to locate multiple leaks or PD in real-time, faster than ever before!\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/6xzVwLdnFhE?start=12\" height=\"315\" width=\"560\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eQuick and easy partial discharge detection and PD testing\u003c\/li\u003e\n\u003cli\u003eReduce outages and increase uptime\u003c\/li\u003e\n\u003cli\u003eCut costs and save energy everyday by finding and fixing PD\u003c\/li\u003e\n\u003cli\u003ePDQ Mode to capture and analyze partial discharge\u003c\/li\u003e\n\u003cli\u003eDo more with the same air compressors – delay the capital expense of purchasing an additional compressor\u003c\/li\u003e\n\u003cli\u003eEnsure proper air pressure to your pneumatic equipment\u003c\/li\u003e\n\u003cli\u003eLower utility costs\u003c\/li\u003e\n\u003cli\u003eReduce leak detection time\u003c\/li\u003e\n\u003cli\u003eImprove reliability in your production line\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSensors\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency band\u003c\/td\u003e\n\u003ctd\u003e2 kHz to 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection range\u003c\/td\u003e\n\u003ctd\u003e0.5 to \u0026gt; 120 meters (1.6 to \u0026gt; 393 feet)*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of View\u003c\/td\u003e\n\u003ctd\u003e63 ° ± 5 °\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal frame rate\u003c\/td\u003e\n\u003ctd\u003e25 FPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003csmall\u003e*Depending on ambient conditions\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eBuilt-in digital camera (visible light)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of View (FOV)\u003c\/td\u003e\n\u003ctd\u003e63 ° ± 5 °\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFocus\u003c\/td\u003e\n\u003ctd\u003eFixed lens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eDisplay\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e7\" LCD with backlight, under-sunlight readable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1280 x 800 (1,024,000 pixels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen\u003c\/td\u003e\n\u003ctd\u003eCapacitive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcoustic image\u003c\/td\u003e\n\u003ctd\u003eYes, SoundMap™ image\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eImage storage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage capacity\u003c\/td\u003e\n\u003ctd\u003eInternal memory with the capacity for 999 picture files and 20 video files\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage format\u003c\/td\u003e\n\u003ctd\u003eBlended visual and SoundMap™.JPG or .PNG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVideo format\u003c\/td\u003e\n\u003ctd\u003eBlended visual and SoundMap™.MP4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVideo length\u003c\/td\u003e\n\u003ctd\u003e5 minutes maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital export\u003c\/td\u003e\n\u003ctd\u003eUSB-C for data transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eImager\u003c\/li\u003e\n\u003cli\u003eAC power supply and battery pack charger (including universal AC adapters)\u003c\/li\u003e\n\u003cli\u003eTwo rugged lithium ion smart battery packs\u003c\/li\u003e\n\u003cli\u003eUSB cable\u003c\/li\u003e\n\u003cli\u003eRugged, hard carrying case\u003c\/li\u003e\n\u003cli\u003eAdjustable hand strap and neck strap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca title=\"Fluke ii910 Acoustic Imager Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_ii900-910_Spec_Sheet.pdf?v=1626100077\" target=\"_blank\"\u003eFluke ii910 Acoustic Imager Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke ii910 Precision Acoustic Imager

Fluke ii910 Precision Acoustic Imager

$38,827.99 CAD

*AVAILABLE FOR RENT - Call us for more information* Finally, an easy way to detect, locate, and analyze leaks and partial discharge in one tool. Building on the game changing ii900 that was introduced in the fall of 2019, the Fluke ii910 Precision Acoustic Imager has been engineered with extra precision to locate gas and vacuum leaks up to 120 ...


More Info
{"id":6624533905598,"title":"Fluke 378FC Non-Contact True RMS AC\/DC Clamp Meter w\/ Power Quality Indicator","handle":"fluke-378fc-non-contact-true-rms-ac-dc-clamp-meter-w-power-quality-indicator","description":"\u003cp\u003eThe Fluke 378 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.\u003c\/p\u003e\n\u003ch3\u003ePower quality indicator shows whether a problem is in the equipment or the power line\u003c\/h3\u003e\n\u003cp\u003eThe 378 FC clamp meter includes a unique PQ function that senses power quality issues automatically. When making FieldSense measurements, the 378 FC will detect and display power quality issues, relating to current, voltage, power factor or any combination of the three. Now you can quickly determine if an upstream supply problem exists, or if there is a downstream equipment problem.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/Fykn84SHes0\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure voltage and current with your clamp jaw\u003c\/li\u003e\n\u003cli\u003eFaster, safer testing all without touching a live wire using FieldSense™ technology\u003c\/li\u003e\n\u003cli\u003eComplete three-phase voltage and current tests in three quick steps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower quality indicator shows whether a problem is in the equipment or the power line\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis clamp meter includes a unique PQ function that senses power quality issues automatically. When making FieldSense measurements, it will detect and display power quality issues, relating to current, voltage, power factor or any combination of the three. Now you can quickly determine if an upstream supply problem exists, or if there is a downstream equipment problem.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage and current measurements with FieldSense™ technology\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo more hand-written notes or complicated math.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete 3-phase voltage and current tests in three easy steps\u003c\/li\u003e\n\u003cli\u003eFull set of phase-to-ground and phase-to-phase values calculated\u003c\/li\u003e\n\u003cli\u003eDisplayed on your smart phone and saved to the cloud via Fluke Connect software\u003c\/li\u003e\n\u003cli\u003ePhase rotation calculated and shown on the Fluke Connect software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasure extremely high current with iFlex™ probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy to see, easy to use with included tools\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYour job will get easier when you use this clamp meter:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe display turns green when a stable FieldSense measurement is detected\u003c\/li\u003e\n\u003cli\u003eVisual Continuity provides a bright green screen for easy detection of continuity in noisy work areas\u003c\/li\u003e\n\u003cli\u003eThe magnetic hanging kit, with 9\" (23 cm) hanging strap, lets you hang your clamp wherever you need: to a steel cabinet door; around a pipe; on a nail or screw head\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19px;\"\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 114px;\"\u003e\n\u003ctd style=\"height: 114px;\"\u003eAC - Jaw\u003c\/td\u003e\n\u003ctd style=\"height: 114px;\"\u003eRange: 999.9 A\u003cbr\u003eResolution: 0.1 A\u003cbr\u003eAccuracy: 2% ±5 digits (10 to 100 Hz); 2.5% ±5 digits (100 to 500 Hz)\u003cbr\u003eCrest factor (50\/60 Hz): 3 at 500 A; 2.5 at 600 A; 1.42 at 1000 A; Add 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eAC - Flexible Current Probe\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 2500 A\u003cbr\u003eResolution: 1 A (≤2500 A) 0.1 A (≤999.9 A)\u003cbr\u003eAccuracy: 3% ±5 digits (5 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eDC\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 999.9 A\u003cbr\u003eResolution: 0.1 A\u003cbr\u003eAccuracy: 2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 76px;\"\u003e\n\u003ctd style=\"height: 76px;\"\u003eAC - FieldSense\u003c\/td\u003e\n\u003ctd style=\"height: 76px;\"\u003eRange: 1000 V\u003cbr\u003eResolution: 1 V (≤1000 V)\u003cbr\u003eAccuracy: ≤4\/0 AWG - 3% ±5 digits (45 to 66 Hz); ≥4\/0 AWG - 5% ±5 digits (45 to 66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eAC - Test Leads\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 600.0 V, 1000 V\u003cbr\u003eResolution: 0.1 V (≤600.0 V); 1 V (≤1000 V)\u003cbr\u003eAccuracy: 1% ±5 digits (20 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eDC\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 600 V, 1000 V\u003cbr\u003eResolution: 0.1 V (≤600 V); 1 V (≤1000 V)\u003cbr\u003eAccuracy: 1% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003emV DC\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 500 mV\u003cbr\u003eResolution: 0.1 mV\u003cbr\u003eAccuracy: 1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19px;\"\u003e\u003cstrong\u003eAmps Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 95px;\"\u003e\n\u003ctd style=\"height: 95px;\"\u003eJaw\u003c\/td\u003e\n\u003ctd style=\"height: 95px;\"\u003eRange: 5 to 500 Hz\u003cbr\u003eResolution: 0.1 Hz\u003cbr\u003eAccuracy: 0.5% ±5 digits\u003cbr\u003eTrigger level: 5 to 10 Hz, ≥10 A; 10 to 100 Hz, ≥5 A; 100 to 500 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 95px;\"\u003e\n\u003ctd style=\"height: 95px;\"\u003eFlexible Current Probe\u003c\/td\u003e\n\u003ctd style=\"height: 95px;\"\u003eRange: 5 to 500 Hz\u003cbr\u003eResolution: 0.1 Hz\u003cbr\u003eAccuracy: 0.5% ±5 digits\u003cbr\u003eTrigger level: 5 to 20 Hz, ≥25 A; 20 to 100 Hz, ≥20 A; 100 to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19px;\"\u003e\u003cstrong\u003eOther Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 60 kΩ, 6000 Ω, 600 Ω\u003cbr\u003eResolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 10 Ω (≤60 kΩ)\u003cbr\u003eAccuracy: 1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 1000 μF\u003cbr\u003eResolution: 0.1 μF (≤100 μF), 1 F (≤1000 μF)\u003cbr\u003eAccuracy: 1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 5.375px;\"\u003e\n\u003ctd style=\"height: 5.375px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 5.375px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 12px;\"\u003e\n\u003ctd style=\"height: 12px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 12px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 378 FC Non-Contact Voltage True-RMS AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003eTL224 Test Leads\u003c\/li\u003e\n\u003cli\u003eTP175 TwistGuard™ Test Probes\u003c\/li\u003e\n\u003cli\u003eAC285 black grounding clip (1 only)\u003c\/li\u003e\n\u003cli\u003ei2500-18 iFlex® Flexible Current Probes 18 inch (48 cm)\u003c\/li\u003e\n\u003cli\u003eTPAK ToolPak™ Magnetic Meter Hanger\u003c\/li\u003e\n\u003cli\u003ePremium carrying case\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_377-378_Clamp_Meter_Spec_Sheet.pdf?v=1618499642\" title=\"Fluke 377FC Non-Contact True RMS AC\/DC Clamp Meter\" target=\"_blank\"\u003eFluke 378FC Non-Contact True RMS AC\/DC Clamp Meter) Spec Sheet\u003c\/a\u003e\u003c!-- split --\u003e","published_at":"2021-04-15T10:16:55-06:00","created_at":"2021-04-15T10:08:52-06:00","vendor":"Fluke","type":"Clamp Meters","tags":[],"price":126479,"price_min":126479,"price_max":126479,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39547193426110,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-378FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 378FC Non-Contact True RMS AC\/DC Clamp Meter w\/ Power Quality Indicator","public_title":null,"options":["Default Title"],"price":126479,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969916615","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378.jpg?v=1618503371","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378_2.jpg?v=1618503381","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378_3.jpg?v=1618503393","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377Pic2_c52650d4-67e0-407b-ab96-5821114739d9.jpg?v=1620740477"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378.jpg?v=1618503371","options":["Title"],"media":[{"alt":null,"id":20588553404606,"position":1,"preview_image":{"aspect_ratio":0.487,"height":1500,"width":731,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378.jpg?v=1618503371"},"aspect_ratio":0.487,"height":1500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378.jpg?v=1618503371","width":731},{"alt":null,"id":20588554027198,"position":2,"preview_image":{"aspect_ratio":0.791,"height":1500,"width":1187,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378_2.jpg?v=1618503381"},"aspect_ratio":0.791,"height":1500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378_2.jpg?v=1618503381","width":1187},{"alt":null,"id":20588554420414,"position":3,"preview_image":{"aspect_ratio":1.499,"height":1001,"width":1500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378_3.jpg?v=1618503393"},"aspect_ratio":1.499,"height":1001,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378_3.jpg?v=1618503393","width":1500},{"alt":null,"id":20844773376190,"position":4,"preview_image":{"aspect_ratio":0.714,"height":1500,"width":1071,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377Pic2_c52650d4-67e0-407b-ab96-5821114739d9.jpg?v=1620740477"},"aspect_ratio":0.714,"height":1500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377Pic2_c52650d4-67e0-407b-ab96-5821114739d9.jpg?v=1620740477","width":1071}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe Fluke 378 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.\u003c\/p\u003e\n\u003ch3\u003ePower quality indicator shows whether a problem is in the equipment or the power line\u003c\/h3\u003e\n\u003cp\u003eThe 378 FC clamp meter includes a unique PQ function that senses power quality issues automatically. When making FieldSense measurements, the 378 FC will detect and display power quality issues, relating to current, voltage, power factor or any combination of the three. Now you can quickly determine if an upstream supply problem exists, or if there is a downstream equipment problem.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/Fykn84SHes0\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure voltage and current with your clamp jaw\u003c\/li\u003e\n\u003cli\u003eFaster, safer testing all without touching a live wire using FieldSense™ technology\u003c\/li\u003e\n\u003cli\u003eComplete three-phase voltage and current tests in three quick steps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower quality indicator shows whether a problem is in the equipment or the power line\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis clamp meter includes a unique PQ function that senses power quality issues automatically. When making FieldSense measurements, it will detect and display power quality issues, relating to current, voltage, power factor or any combination of the three. Now you can quickly determine if an upstream supply problem exists, or if there is a downstream equipment problem.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage and current measurements with FieldSense™ technology\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo more hand-written notes or complicated math.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete 3-phase voltage and current tests in three easy steps\u003c\/li\u003e\n\u003cli\u003eFull set of phase-to-ground and phase-to-phase values calculated\u003c\/li\u003e\n\u003cli\u003eDisplayed on your smart phone and saved to the cloud via Fluke Connect software\u003c\/li\u003e\n\u003cli\u003ePhase rotation calculated and shown on the Fluke Connect software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasure extremely high current with iFlex™ probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy to see, easy to use with included tools\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYour job will get easier when you use this clamp meter:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe display turns green when a stable FieldSense measurement is detected\u003c\/li\u003e\n\u003cli\u003eVisual Continuity provides a bright green screen for easy detection of continuity in noisy work areas\u003c\/li\u003e\n\u003cli\u003eThe magnetic hanging kit, with 9\" (23 cm) hanging strap, lets you hang your clamp wherever you need: to a steel cabinet door; around a pipe; on a nail or screw head\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19px;\"\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 114px;\"\u003e\n\u003ctd style=\"height: 114px;\"\u003eAC - Jaw\u003c\/td\u003e\n\u003ctd style=\"height: 114px;\"\u003eRange: 999.9 A\u003cbr\u003eResolution: 0.1 A\u003cbr\u003eAccuracy: 2% ±5 digits (10 to 100 Hz); 2.5% ±5 digits (100 to 500 Hz)\u003cbr\u003eCrest factor (50\/60 Hz): 3 at 500 A; 2.5 at 600 A; 1.42 at 1000 A; Add 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eAC - Flexible Current Probe\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 2500 A\u003cbr\u003eResolution: 1 A (≤2500 A) 0.1 A (≤999.9 A)\u003cbr\u003eAccuracy: 3% ±5 digits (5 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eDC\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 999.9 A\u003cbr\u003eResolution: 0.1 A\u003cbr\u003eAccuracy: 2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 76px;\"\u003e\n\u003ctd style=\"height: 76px;\"\u003eAC - FieldSense\u003c\/td\u003e\n\u003ctd style=\"height: 76px;\"\u003eRange: 1000 V\u003cbr\u003eResolution: 1 V (≤1000 V)\u003cbr\u003eAccuracy: ≤4\/0 AWG - 3% ±5 digits (45 to 66 Hz); ≥4\/0 AWG - 5% ±5 digits (45 to 66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eAC - Test Leads\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 600.0 V, 1000 V\u003cbr\u003eResolution: 0.1 V (≤600.0 V); 1 V (≤1000 V)\u003cbr\u003eAccuracy: 1% ±5 digits (20 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eDC\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 600 V, 1000 V\u003cbr\u003eResolution: 0.1 V (≤600 V); 1 V (≤1000 V)\u003cbr\u003eAccuracy: 1% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003emV DC\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 500 mV\u003cbr\u003eResolution: 0.1 mV\u003cbr\u003eAccuracy: 1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19px;\"\u003e\u003cstrong\u003eAmps Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 95px;\"\u003e\n\u003ctd style=\"height: 95px;\"\u003eJaw\u003c\/td\u003e\n\u003ctd style=\"height: 95px;\"\u003eRange: 5 to 500 Hz\u003cbr\u003eResolution: 0.1 Hz\u003cbr\u003eAccuracy: 0.5% ±5 digits\u003cbr\u003eTrigger level: 5 to 10 Hz, ≥10 A; 10 to 100 Hz, ≥5 A; 100 to 500 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 95px;\"\u003e\n\u003ctd style=\"height: 95px;\"\u003eFlexible Current Probe\u003c\/td\u003e\n\u003ctd style=\"height: 95px;\"\u003eRange: 5 to 500 Hz\u003cbr\u003eResolution: 0.1 Hz\u003cbr\u003eAccuracy: 0.5% ±5 digits\u003cbr\u003eTrigger level: 5 to 20 Hz, ≥25 A; 20 to 100 Hz, ≥20 A; 100 to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19px;\"\u003e\u003cstrong\u003eOther Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 60 kΩ, 6000 Ω, 600 Ω\u003cbr\u003eResolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 10 Ω (≤60 kΩ)\u003cbr\u003eAccuracy: 1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 1000 μF\u003cbr\u003eResolution: 0.1 μF (≤100 μF), 1 F (≤1000 μF)\u003cbr\u003eAccuracy: 1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 5.375px;\"\u003e\n\u003ctd style=\"height: 5.375px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 5.375px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 12px;\"\u003e\n\u003ctd style=\"height: 12px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 12px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 378 FC Non-Contact Voltage True-RMS AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003eTL224 Test Leads\u003c\/li\u003e\n\u003cli\u003eTP175 TwistGuard™ Test Probes\u003c\/li\u003e\n\u003cli\u003eAC285 black grounding clip (1 only)\u003c\/li\u003e\n\u003cli\u003ei2500-18 iFlex® Flexible Current Probes 18 inch (48 cm)\u003c\/li\u003e\n\u003cli\u003eTPAK ToolPak™ Magnetic Meter Hanger\u003c\/li\u003e\n\u003cli\u003ePremium carrying case\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_377-378_Clamp_Meter_Spec_Sheet.pdf?v=1618499642\" title=\"Fluke 377FC Non-Contact True RMS AC\/DC Clamp Meter\" target=\"_blank\"\u003eFluke 378FC Non-Contact True RMS AC\/DC Clamp Meter) Spec Sheet\u003c\/a\u003e\u003c!-- split --\u003e"}
Fluke 378FC Non-Contact True RMS AC/DC Clamp Meter w/ Power Quality Indicator

Fluke 378FC Non-Contact True RMS AC/DC Clamp Meter w/ Power Quality Indicator

$1,264.79 CAD

The Fluke 378 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage a...


More Info
{"id":6624368820414,"title":"Fluke 377FC Non-Contact True RMS AC\/DC Clamp Meter","handle":"fluke-377fc-non-contact-true-rms-ac-dc-clamp-meter","description":"\u003cp\u003e\u003cspan\u003eThe Fluke 377 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/Fykn84SHes0\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure voltage and current with your clamp jaw\u003c\/li\u003e\n\u003cli\u003eFaster, safer testing all without touching a live wire using FieldSense™ technology\u003c\/li\u003e\n\u003cli\u003eComplete three-phase voltage and current tests in three quick steps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage and current measurements with FieldSense™ technology\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo more hand-written notes or complicated math.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete 3-phase voltage and current tests in three easy steps\u003c\/li\u003e\n\u003cli\u003eFull set of phase-to-ground and phase-to-phase values calculated\u003c\/li\u003e\n\u003cli\u003eDisplayed on your smart phone and saved to the cloud via Fluke Connect software\u003c\/li\u003e\n\u003cli\u003ePhase rotation calculated and shown on the Fluke Connect software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasure extremely high current with iFlex™ probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy to see, easy to use with included tools\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYour job will get easier when you use this clamp meter:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe display turns green when a stable FieldSense measurement is detected\u003c\/li\u003e\n\u003cli\u003eVisual Continuity provides a bright green screen for easy detection of continuity in noisy work areas\u003c\/li\u003e\n\u003cli\u003eThe magnetic hanging kit, with 9\" (23 cm) hanging strap, lets you hang your clamp wherever you need: to a steel cabinet door; around a pipe; on a nail or screw head\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC - Jaw\u003c\/td\u003e\n\u003ctd\u003eRange: 999.9 A\u003cbr\u003eResolution: 0.1 A\u003cbr\u003eAccuracy: 2% ±5 digits (10 to 100 Hz); 2.5% ±5 digits (100 to 500 Hz)\u003cbr\u003eCrest factor (50\/60 Hz): 3 at 500 A; 2.5 at 600 A; 1.42 at 1000 A; Add 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC - Flexible Current Probe\u003c\/td\u003e\n\u003ctd\u003eRange: 2500 A\u003cbr\u003eResolution: 1 A (≤2500 A) 0.1 A (≤999.9 A)\u003cbr\u003eAccuracy: 3% ±5 digits (5 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003ctd\u003eRange: 999.9 A\u003cbr\u003eResolution: 0.1 A\u003cbr\u003eAccuracy: 2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC - FieldSense\u003c\/td\u003e\n\u003ctd\u003eRange: 1000 V\u003cbr\u003eResolution: 1 V (≤1000 V)\u003cbr\u003eAccuracy: ≤4\/0 AWG - 3% ±5 digits (45 to 66 Hz); ≥4\/0 AWG - 5% ±5 digits (45 to 66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC - Test Leads\u003c\/td\u003e\n\u003ctd\u003eRange: 600.0 V, 1000 V\u003cbr\u003eResolution: 0.1 V (≤600.0 V); 1 V (≤1000 V)\u003cbr\u003eAccuracy: 1% ±5 digits (20 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003ctd\u003eRange: 600 V, 1000 V\u003cbr\u003eResolution: 0.1 V (≤600 V); 1 V (≤1000 V)\u003cbr\u003eAccuracy: 1% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV DC\u003c\/td\u003e\n\u003ctd\u003eRange: 500 mV\u003cbr\u003eResolution: 0.1 mV\u003cbr\u003eAccuracy: 1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAmps Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw\u003c\/td\u003e\n\u003ctd\u003eRange: 5 to 500 Hz\u003cbr\u003eResolution: 0.1 Hz\u003cbr\u003eAccuracy: 0.5% ±5 digits\u003cbr\u003eTrigger level: 5 to 10 Hz, ≥10 A; 10 to 100 Hz, ≥5 A; 100 to 500 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe\u003c\/td\u003e\n\u003ctd\u003eRange: 5 to 500 Hz\u003cbr\u003eResolution: 0.1 Hz\u003cbr\u003eAccuracy: 0.5% ±5 digits\u003cbr\u003eTrigger level: 5 to 20 Hz, ≥25 A; 20 to 100 Hz, ≥20 A; 100 to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOther Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eRange: 60 kΩ, 6000 Ω, 600 Ω\u003cbr\u003eResolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 10 Ω (≤60 kΩ)\u003cbr\u003eAccuracy: 1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003eRange: 1000 μF\u003cbr\u003eResolution: 0.1 μF (≤100 μF), 1 F (≤1000 μF)\u003cbr\u003eAccuracy: 1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Maximum Voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V (between any terminal and earth ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eType: 2 x AA IEC LR6 alkaline\u003cbr\u003elife: 200 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDual readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd\u003e20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eOperating: 14 to 122°F (-10 to 50°C)\u003cbr\u003eStorage: -40 to 140°F (-40 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity (Without Condensation)\u003c\/td\u003e\n\u003ctd\u003eNon condensing (\u0026lt;50°F [\u0026lt;10°C])\u003cbr\u003e≤90% RH (50 to 86°F [10 to 30°C])\u003cbr\u003e≤75% RH (86 to 104°F [30 to 40°C])\u003cbr\u003e≤45% RH (104 to 122°F [40 to 50°C])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficients\u003c\/td\u003e\n\u003ctd\u003eAdd 0.1 x specified accuracy for each degree C \u0026gt;28°C or \u0026lt;18°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIEC 60529: IP30 (jaw closed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitute\u003c\/td\u003e\n\u003ctd\u003eOperating: 6561.68' (2000 m)\u003cbr\u003eStorage: 39,370.1' (12,000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\n\u003ctd\u003eUSA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eGeneral: IEC 61010-1: Pollution degree 2\u003cbr\u003eMeasurement: IEC 61010-2-032: CAT III 1000 V\/CAT IV 600 V; IEC 61010-2-033: CAT III 1000 V\/CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWireless Radio\u003c\/td\u003e\n\u003ctd\u003eRadio frequency certification: FCC ID: T68-FBLE IC:6627A-FBLE\u003cbr\u003eFrequency range: 2405 to 2480 MHz\u003cbr\u003eOutput power: \u0026lt;100 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.78 x 3.38 x 1.85\" (274 x 86 x 47 mm)\u003cbr\u003eJaw opening: 1.34\" (34 mm)\u003cbr\u003eFlexible current probe diameter: 0.29\" (7.5 mm)\u003cbr\u003eFlexible current probe cable length: 5.9' (1.8 m)\u003cbr\u003eRogowski coil length: 17.71\" (450 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs (463 g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 377 FC Non-Contact Voltage True-RMS AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003eTL224 Test Leads\u003c\/li\u003e\n\u003cli\u003eTP175 TwistGuard™ Test Probes\u003c\/li\u003e\n\u003cli\u003eAC285 black grounding clip (1 only)\u003c\/li\u003e\n\u003cli\u003ei2500-18 iFlex® Flexible Current Probes 18 inch (48 cm)\u003c\/li\u003e\n\u003cli\u003eTPAK ToolPak™ Magnetic Meter Hanger\u003c\/li\u003e\n\u003cli\u003ePremium carrying case\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003ca title=\"Fluke 377FC Non-Contact True RMS AC\/DC Clamp Meter\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_377-378_Clamp_Meter_Spec_Sheet.pdf?v=1618499642\" target=\"_blank\"\u003eFluke 377FC Non-Contact True RMS AC\/DC Clamp Meter) Spec Sheet\u003c\/a\u003e\u003c!-- split --\u003e","published_at":"2021-04-15T09:16:14-06:00","created_at":"2021-04-15T09:16:13-06:00","vendor":"Fluke","type":"Clamp Meters","tags":[],"price":106079,"price_min":106079,"price_max":106079,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39546910572734,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-377FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 377FC Non-Contact True RMS AC\/DC Clamp Meter","public_title":null,"options":["Default Title"],"price":106079,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969916608","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377.jpg?v=1620740376","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377Pic2.jpg?v=1620740415"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377.jpg?v=1620740376","options":["Title"],"media":[{"alt":null,"id":20844763644094,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377.jpg?v=1620740376"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377.jpg?v=1620740376","width":1000},{"alt":null,"id":20844766855358,"position":2,"preview_image":{"aspect_ratio":0.714,"height":1500,"width":1071,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377Pic2.jpg?v=1620740415"},"aspect_ratio":0.714,"height":1500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377Pic2.jpg?v=1620740415","width":1071}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Fluke 377 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/Fykn84SHes0\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure voltage and current with your clamp jaw\u003c\/li\u003e\n\u003cli\u003eFaster, safer testing all without touching a live wire using FieldSense™ technology\u003c\/li\u003e\n\u003cli\u003eComplete three-phase voltage and current tests in three quick steps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage and current measurements with FieldSense™ technology\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo more hand-written notes or complicated math.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete 3-phase voltage and current tests in three easy steps\u003c\/li\u003e\n\u003cli\u003eFull set of phase-to-ground and phase-to-phase values calculated\u003c\/li\u003e\n\u003cli\u003eDisplayed on your smart phone and saved to the cloud via Fluke Connect software\u003c\/li\u003e\n\u003cli\u003ePhase rotation calculated and shown on the Fluke Connect software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasure extremely high current with iFlex™ probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy to see, easy to use with included tools\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYour job will get easier when you use this clamp meter:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe display turns green when a stable FieldSense measurement is detected\u003c\/li\u003e\n\u003cli\u003eVisual Continuity provides a bright green screen for easy detection of continuity in noisy work areas\u003c\/li\u003e\n\u003cli\u003eThe magnetic hanging kit, with 9\" (23 cm) hanging strap, lets you hang your clamp wherever you need: to a steel cabinet door; around a pipe; on a nail or screw head\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC - Jaw\u003c\/td\u003e\n\u003ctd\u003eRange: 999.9 A\u003cbr\u003eResolution: 0.1 A\u003cbr\u003eAccuracy: 2% ±5 digits (10 to 100 Hz); 2.5% ±5 digits (100 to 500 Hz)\u003cbr\u003eCrest factor (50\/60 Hz): 3 at 500 A; 2.5 at 600 A; 1.42 at 1000 A; Add 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC - Flexible Current Probe\u003c\/td\u003e\n\u003ctd\u003eRange: 2500 A\u003cbr\u003eResolution: 1 A (≤2500 A) 0.1 A (≤999.9 A)\u003cbr\u003eAccuracy: 3% ±5 digits (5 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003ctd\u003eRange: 999.9 A\u003cbr\u003eResolution: 0.1 A\u003cbr\u003eAccuracy: 2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC - FieldSense\u003c\/td\u003e\n\u003ctd\u003eRange: 1000 V\u003cbr\u003eResolution: 1 V (≤1000 V)\u003cbr\u003eAccuracy: ≤4\/0 AWG - 3% ±5 digits (45 to 66 Hz); ≥4\/0 AWG - 5% ±5 digits (45 to 66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC - Test Leads\u003c\/td\u003e\n\u003ctd\u003eRange: 600.0 V, 1000 V\u003cbr\u003eResolution: 0.1 V (≤600.0 V); 1 V (≤1000 V)\u003cbr\u003eAccuracy: 1% ±5 digits (20 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003ctd\u003eRange: 600 V, 1000 V\u003cbr\u003eResolution: 0.1 V (≤600 V); 1 V (≤1000 V)\u003cbr\u003eAccuracy: 1% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV DC\u003c\/td\u003e\n\u003ctd\u003eRange: 500 mV\u003cbr\u003eResolution: 0.1 mV\u003cbr\u003eAccuracy: 1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAmps Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw\u003c\/td\u003e\n\u003ctd\u003eRange: 5 to 500 Hz\u003cbr\u003eResolution: 0.1 Hz\u003cbr\u003eAccuracy: 0.5% ±5 digits\u003cbr\u003eTrigger level: 5 to 10 Hz, ≥10 A; 10 to 100 Hz, ≥5 A; 100 to 500 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe\u003c\/td\u003e\n\u003ctd\u003eRange: 5 to 500 Hz\u003cbr\u003eResolution: 0.1 Hz\u003cbr\u003eAccuracy: 0.5% ±5 digits\u003cbr\u003eTrigger level: 5 to 20 Hz, ≥25 A; 20 to 100 Hz, ≥20 A; 100 to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOther Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eRange: 60 kΩ, 6000 Ω, 600 Ω\u003cbr\u003eResolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 10 Ω (≤60 kΩ)\u003cbr\u003eAccuracy: 1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003eRange: 1000 μF\u003cbr\u003eResolution: 0.1 μF (≤100 μF), 1 F (≤1000 μF)\u003cbr\u003eAccuracy: 1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Maximum Voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V (between any terminal and earth ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eType: 2 x AA IEC LR6 alkaline\u003cbr\u003elife: 200 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDual readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd\u003e20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eOperating: 14 to 122°F (-10 to 50°C)\u003cbr\u003eStorage: -40 to 140°F (-40 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity (Without Condensation)\u003c\/td\u003e\n\u003ctd\u003eNon condensing (\u0026lt;50°F [\u0026lt;10°C])\u003cbr\u003e≤90% RH (50 to 86°F [10 to 30°C])\u003cbr\u003e≤75% RH (86 to 104°F [30 to 40°C])\u003cbr\u003e≤45% RH (104 to 122°F [40 to 50°C])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficients\u003c\/td\u003e\n\u003ctd\u003eAdd 0.1 x specified accuracy for each degree C \u0026gt;28°C or \u0026lt;18°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIEC 60529: IP30 (jaw closed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitute\u003c\/td\u003e\n\u003ctd\u003eOperating: 6561.68' (2000 m)\u003cbr\u003eStorage: 39,370.1' (12,000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\n\u003ctd\u003eUSA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eGeneral: IEC 61010-1: Pollution degree 2\u003cbr\u003eMeasurement: IEC 61010-2-032: CAT III 1000 V\/CAT IV 600 V; IEC 61010-2-033: CAT III 1000 V\/CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWireless Radio\u003c\/td\u003e\n\u003ctd\u003eRadio frequency certification: FCC ID: T68-FBLE IC:6627A-FBLE\u003cbr\u003eFrequency range: 2405 to 2480 MHz\u003cbr\u003eOutput power: \u0026lt;100 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.78 x 3.38 x 1.85\" (274 x 86 x 47 mm)\u003cbr\u003eJaw opening: 1.34\" (34 mm)\u003cbr\u003eFlexible current probe diameter: 0.29\" (7.5 mm)\u003cbr\u003eFlexible current probe cable length: 5.9' (1.8 m)\u003cbr\u003eRogowski coil length: 17.71\" (450 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs (463 g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 377 FC Non-Contact Voltage True-RMS AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003eTL224 Test Leads\u003c\/li\u003e\n\u003cli\u003eTP175 TwistGuard™ Test Probes\u003c\/li\u003e\n\u003cli\u003eAC285 black grounding clip (1 only)\u003c\/li\u003e\n\u003cli\u003ei2500-18 iFlex® Flexible Current Probes 18 inch (48 cm)\u003c\/li\u003e\n\u003cli\u003eTPAK ToolPak™ Magnetic Meter Hanger\u003c\/li\u003e\n\u003cli\u003ePremium carrying case\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003ca title=\"Fluke 377FC Non-Contact True RMS AC\/DC Clamp Meter\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_377-378_Clamp_Meter_Spec_Sheet.pdf?v=1618499642\" target=\"_blank\"\u003eFluke 377FC Non-Contact True RMS AC\/DC Clamp Meter) Spec Sheet\u003c\/a\u003e\u003c!-- split --\u003e"}
Fluke 377FC Non-Contact True RMS AC/DC Clamp Meter

Fluke 377FC Non-Contact True RMS AC/DC Clamp Meter

$1,060.79 CAD

The Fluke 377 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage a...


More Info
Fluke 107 Palm-Sized Multimeter, 600V

Multimeters

$213.71 CAD
{"id":4512157171785,"title":"Fluke 107 Palm-Sized Multimeter, 600V","handle":"fluke-107-palm-sized-multimeter-600v","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 107 is a compact, easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool: small enough to fit in a shirt pocket or work bag, tough enough to withstand daily use, and extremely simple to use. All without compromising safety. For everyday applications, where True-RMS accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"PrdPlainText\"\u003eAlso check out the Fluke 115 Electrical Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117 Electrician’s Multimeter with Non-contact voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch3\u003eFluke 107 Complete test functions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC and DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eAC and DC current measurement\u003c\/li\u003e\n\u003cli\u003eResistance measurement\u003c\/li\u003e\n\u003cli\u003eCapacitance measurement\u003c\/li\u003e\n\u003cli\u003eDiode measurement\u003c\/li\u003e\n\u003cli\u003eFrequency and duty cycle test and other functions to meet basic electrical maintenance, electrical measurement, and electronic measurement applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eErgonomic and Rugged\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComfortable grip, only weighs 200g and easy to carry\u003c\/li\u003e\n\u003cli\u003eRugged enclosure and 1-meter drop test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFluke 107 Additional Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFull-parameter automatic range test, which is convenient and quick to test; at the same time, it reduces the number of rotations of the wave plate and prolongs the life of the instrument.\u003c\/li\u003e\n\u003cli\u003e6000-word large screen LCD backlight display\u003c\/li\u003e\n\u003cli\u003eBattery powered, automatic power save mode\u003c\/li\u003e\n\u003cli\u003eData retention feature makes it easier to read measurement results\u003c\/li\u003e\n\u003cli\u003eComes with SmartStrap™ intelligent magnetic multi-purpose lanyard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003ePrecision specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"2\"\u003e\u003cstrong\u003eAC voltage\u003cbr\u003e(40 Hz to 500 Hz)\u003csup\u003e1\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6.000 V\u003cbr\u003e60.00 V\u003cbr\u003e600.0 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003cbr\u003e0.01 V\u003cbr\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e1.0 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V\u003cbr\u003e60.00 V\u003cbr\u003e600.0 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003cbr\u003e0.01 V\u003cbr\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e0.5 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eExchange millivolts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003ctd\u003e3.0 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDiode test\u003csup\u003e2\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.000 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003ctd\u003e10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResistance\u003cbr\u003e(ohm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω\u003cbr\u003e4.000 kΩ\u003cbr\u003e40.00 kΩ\u003cbr\u003e400.0 kΩ\u003cbr\u003e4.000 MΩ\u003cbr\u003e40.00 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003cbr\u003e0.001 kΩ\u003cbr\u003e0.01 kΩ\u003cbr\u003e0.1 kΩ\u003cbr\u003e0.001 MΩ\u003cbr\u003e0.01 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.5 % + 3\u003cbr\u003e0.5 % + 2\u003cbr\u003e0.5 % + 2\u003cbr\u003e0.5 % + 2\u003cbr\u003e0.5 % + 2\u003cbr\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCapacitor\u003csup\u003e3\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.00 nF\u003cbr\u003e500.0 nF\u003cbr\u003e5.000 μF\u003cbr\u003e50.00 μF\u003cbr\u003e500.0 μF\u003cbr\u003e1000 μF\u003c\/td\u003e\n\u003ctd\u003e0.01 nF\u003cbr\u003e0.1 nF\u003cbr\u003e0.001 μF\u003cbr\u003e0.01 μF\u003cbr\u003e0.1 μF\u003cbr\u003e1 μF\u003c\/td\u003e\n\u003ctd\u003e2 % + 5\u003cbr\u003e2 % + 5\u003cbr\u003e5 % + 5\u003cbr\u003e5 % + 5\u003cbr\u003e5 % + 5\u003cbr\u003e5 % + 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFrequency\u003csup\u003e4\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHz\u003cbr\u003e(10 Hz – 100 kHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.00 Hz\u003cbr\u003e500.0 Hz\u003cbr\u003e5.000 kHz\u003cbr\u003e50.00 kHz\u003cbr\u003e100.0 kHz\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003cbr\u003e0.1 Hz\u003cbr\u003e0.001 kHz\u003cbr\u003e0.01 kHz\u003cbr\u003e0.1 kHz\u003c\/td\u003e\n\u003ctd\u003e0.1 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDuty cycle\u003csup\u003e4\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 % to 99 %\u003c\/td\u003e\n\u003ctd\u003e0.10 %\u003c\/td\u003e\n\u003ctd\u003e1 % typical case\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAC current\u003cbr\u003e(40 Hz - 200 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.000 A\u003cbr\u003e10.00 A\u003c\/td\u003e\n\u003ctd\u003e0.001 A\u003cbr\u003e0.01 A\u003c\/td\u003e\n\u003ctd\u003e1.5 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.000 A\u003cbr\u003e10.00 A\u003c\/td\u003e\n\u003ctd\u003e0.001 A\u003cbr\u003e0.01 A\u003c\/td\u003e\n\u003ctd\u003e1.5 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2 class=\"hidden\"\u003e\u003c\/h2\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 107 Palm-sized, CAT III Digital Multimeter\u003c\/li\u003e\n\u003cli\u003eTL75 Hard Point™ Test Lead Set\u003c\/li\u003e\n\u003cli\u003eTwo AAA batteries (installed)\u003c\/li\u003e\n\u003cli\u003eSmartStrap™ intelligent magnetic multi-purpose lanyard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_107_Palm-Sized_Multimeter_Spec_Sheet.pdf?v=1594235733\" target=\"_blank\" title=\"Fluke 107 Multimeter Spec sheet\" rel=\"noopener noreferrer\"\u003eFluke 107 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2020-07-08T13:10:41-06:00","created_at":"2020-07-08T13:10:41-06:00","vendor":"Fluke","type":"Multimeters","tags":[],"price":21371,"price_min":21371,"price_max":21371,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":31682510651465,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-107","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 107 Palm-Sized Multimeter, 600V","public_title":null,"options":["Default Title"],"price":21371,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969678780","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke107Pic1.jpg?v=1594235698","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke107Pic2.jpg?v=1594235698"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke107Pic1.jpg?v=1594235698","options":["Title"],"media":[{"alt":null,"id":6415348105289,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke107Pic1.jpg?v=1594235698"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke107Pic1.jpg?v=1594235698","width":1024},{"alt":null,"id":6415348138057,"position":2,"preview_image":{"aspect_ratio":1.0,"height":700,"width":700,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke107Pic2.jpg?v=1594235698"},"aspect_ratio":1.0,"height":700,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke107Pic2.jpg?v=1594235698","width":700}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 107 is a compact, easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool: small enough to fit in a shirt pocket or work bag, tough enough to withstand daily use, and extremely simple to use. All without compromising safety. For everyday applications, where True-RMS accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"PrdPlainText\"\u003eAlso check out the Fluke 115 Electrical Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117 Electrician’s Multimeter with Non-contact voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch3\u003eFluke 107 Complete test functions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC and DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eAC and DC current measurement\u003c\/li\u003e\n\u003cli\u003eResistance measurement\u003c\/li\u003e\n\u003cli\u003eCapacitance measurement\u003c\/li\u003e\n\u003cli\u003eDiode measurement\u003c\/li\u003e\n\u003cli\u003eFrequency and duty cycle test and other functions to meet basic electrical maintenance, electrical measurement, and electronic measurement applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eErgonomic and Rugged\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComfortable grip, only weighs 200g and easy to carry\u003c\/li\u003e\n\u003cli\u003eRugged enclosure and 1-meter drop test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFluke 107 Additional Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFull-parameter automatic range test, which is convenient and quick to test; at the same time, it reduces the number of rotations of the wave plate and prolongs the life of the instrument.\u003c\/li\u003e\n\u003cli\u003e6000-word large screen LCD backlight display\u003c\/li\u003e\n\u003cli\u003eBattery powered, automatic power save mode\u003c\/li\u003e\n\u003cli\u003eData retention feature makes it easier to read measurement results\u003c\/li\u003e\n\u003cli\u003eComes with SmartStrap™ intelligent magnetic multi-purpose lanyard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003ePrecision specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"2\"\u003e\u003cstrong\u003eAC voltage\u003cbr\u003e(40 Hz to 500 Hz)\u003csup\u003e1\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6.000 V\u003cbr\u003e60.00 V\u003cbr\u003e600.0 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003cbr\u003e0.01 V\u003cbr\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e1.0 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V\u003cbr\u003e60.00 V\u003cbr\u003e600.0 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003cbr\u003e0.01 V\u003cbr\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e0.5 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eExchange millivolts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003ctd\u003e3.0 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDiode test\u003csup\u003e2\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.000 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003ctd\u003e10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResistance\u003cbr\u003e(ohm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω\u003cbr\u003e4.000 kΩ\u003cbr\u003e40.00 kΩ\u003cbr\u003e400.0 kΩ\u003cbr\u003e4.000 MΩ\u003cbr\u003e40.00 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003cbr\u003e0.001 kΩ\u003cbr\u003e0.01 kΩ\u003cbr\u003e0.1 kΩ\u003cbr\u003e0.001 MΩ\u003cbr\u003e0.01 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.5 % + 3\u003cbr\u003e0.5 % + 2\u003cbr\u003e0.5 % + 2\u003cbr\u003e0.5 % + 2\u003cbr\u003e0.5 % + 2\u003cbr\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCapacitor\u003csup\u003e3\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.00 nF\u003cbr\u003e500.0 nF\u003cbr\u003e5.000 μF\u003cbr\u003e50.00 μF\u003cbr\u003e500.0 μF\u003cbr\u003e1000 μF\u003c\/td\u003e\n\u003ctd\u003e0.01 nF\u003cbr\u003e0.1 nF\u003cbr\u003e0.001 μF\u003cbr\u003e0.01 μF\u003cbr\u003e0.1 μF\u003cbr\u003e1 μF\u003c\/td\u003e\n\u003ctd\u003e2 % + 5\u003cbr\u003e2 % + 5\u003cbr\u003e5 % + 5\u003cbr\u003e5 % + 5\u003cbr\u003e5 % + 5\u003cbr\u003e5 % + 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFrequency\u003csup\u003e4\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHz\u003cbr\u003e(10 Hz – 100 kHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.00 Hz\u003cbr\u003e500.0 Hz\u003cbr\u003e5.000 kHz\u003cbr\u003e50.00 kHz\u003cbr\u003e100.0 kHz\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003cbr\u003e0.1 Hz\u003cbr\u003e0.001 kHz\u003cbr\u003e0.01 kHz\u003cbr\u003e0.1 kHz\u003c\/td\u003e\n\u003ctd\u003e0.1 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDuty cycle\u003csup\u003e4\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 % to 99 %\u003c\/td\u003e\n\u003ctd\u003e0.10 %\u003c\/td\u003e\n\u003ctd\u003e1 % typical case\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAC current\u003cbr\u003e(40 Hz - 200 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.000 A\u003cbr\u003e10.00 A\u003c\/td\u003e\n\u003ctd\u003e0.001 A\u003cbr\u003e0.01 A\u003c\/td\u003e\n\u003ctd\u003e1.5 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.000 A\u003cbr\u003e10.00 A\u003c\/td\u003e\n\u003ctd\u003e0.001 A\u003cbr\u003e0.01 A\u003c\/td\u003e\n\u003ctd\u003e1.5 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2 class=\"hidden\"\u003e\u003c\/h2\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 107 Palm-sized, CAT III Digital Multimeter\u003c\/li\u003e\n\u003cli\u003eTL75 Hard Point™ Test Lead Set\u003c\/li\u003e\n\u003cli\u003eTwo AAA batteries (installed)\u003c\/li\u003e\n\u003cli\u003eSmartStrap™ intelligent magnetic multi-purpose lanyard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_107_Palm-Sized_Multimeter_Spec_Sheet.pdf?v=1594235733\" target=\"_blank\" title=\"Fluke 107 Multimeter Spec sheet\" rel=\"noopener noreferrer\"\u003eFluke 107 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e"}
Fluke 107 Palm-Sized Multimeter, 600V

Fluke 107 Palm-Sized Multimeter, 600V

$213.71 CAD

The Fluke 107 is a compact, easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool: small enough to fit in a shirt pocket or work bag, tough enough to withstand daily use, and extremely simple to use. All without compromising safety. For everyday applications, where True-RMS accuracy isn’t...


More Info
Fluke 729 Automatic Pressure Calibrator

Pressure Calibrators

$16,018.07 CAD
{"id":4425244508233,"title":"Fluke 729 Automatic Pressure Calibrator","handle":"fluke-729-automatic-pressure-calibrator","description":"\u003cp\u003eThe ideal portable pressure calibrator, the 729 allows you to simply type in a target pressure, and the calibrator will automatically pump to the desired set-point. Then, internal fine adjustment control automatically stabilizes the pressure at the requested value.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 729 can also automatically test multiple pressure test points and automatically document the results. Calibration is as easy as typing in the starting and ending pressure and the number of test points and tolerance level. The 729 does the rest.\u003c\/p\u003e\n\u003cp\u003eBuilt-in HART communication capabilities enable HART transmitter mA adjustments, light HART configuration and the ability to adjust to applied 0% and 100% values.\u003c\/p\u003e\n\u003cp\u003eUpload and manage documented calibration results with DPCTrack2™ Calibration Management Software, making it easy to manage your instrumentation, create scheduled tests and reports, and manage calibration data.\u003c\/p\u003e\n\u003cp\u003eWith three ranges to choose from, 30 psi (2 bar, 200 kPa), 150 psi (10 bar, 1 MPa) and 300 psi (20 bar, 2 MPa), Fluke 729 Automatic Pressure Calibrators are designed to perform when and where you need them.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic pressure generation and regulation to 300 psi\u003c\/li\u003e\n\u003cli\u003eEasily document the process using onboard test templates\u003c\/li\u003e\n\u003cli\u003eAutomatic internal fine-pressure adjustment\u003c\/li\u003e\n\u003cli\u003eMeasure, source and simulate 4 to 20 mA signals\u003c\/li\u003e\n\u003cli\u003e24V loop power for powering transmitters for tests\u003c\/li\u003e\n\u003cli\u003eBright dual\/triple-channel color graphical display\u003c\/li\u003e\n\u003cli\u003eHART communication for testing HART smart transmitters\u003c\/li\u003e\n\u003cli\u003eBuilt-in leak testing for verifying test setups for leakage\u003c\/li\u003e\n\u003cli\u003eRugged portable design with standard 3-year warranty\u003c\/li\u003e\n\u003cli\u003eFluke Connect® App compatibility\u003c\/li\u003e\n\u003cli\u003eMeasure temperature with optional 720RTD probe\u003c\/li\u003e\n\u003cli\u003eMeasure Vdc for testing 1 V dc to 5 V dc output transmitters\u003c\/li\u003e\n\u003cli\u003eCompatible with 700 Series and 750 Series pressure modules\u003c\/li\u003e\n\u003cli\u003eUpload documented test results to DPCTrack2™ Calibration Management Software\u003c\/li\u003e\n\u003cli\u003eInnovative semi-rigid carrying case designed for field work\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003eSee Resources for Product Datasheet\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCalibrator with Wireless Communication\u003c\/li\u003e\n\u003cli\u003eSoft Case\u003c\/li\u003e\n\u003cli\u003eStackable Test Leads\u003c\/li\u003e\n\u003cli\u003eAC280 Hook Clips\u003c\/li\u003e\n\u003cli\u003eAlligator Clips\u003c\/li\u003e\n\u003cli\u003eTest Probes\u003c\/li\u003e\n\u003cli\u003eMagnetic Hanger Kit\u003c\/li\u003e\n\u003cli\u003eCarrying Strap\u003c\/li\u003e\n\u003cli\u003eWireless Adapter\u003c\/li\u003e\n\u003cli\u003eQuick Start Guide\u003c\/li\u003e\n\u003cli\u003eSafety Sheet\u003c\/li\u003e\n\u003cli\u003ePower Supply\u003c\/li\u003e\n\u003cli\u003eRechargeable Battery (installed)\u003c\/li\u003e\n\u003cli\u003eHose Kit with PUsh Fit Adapters\u003c\/li\u003e\n\u003cli\u003eHanging Clip\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003cli\u003e1\/8 in FNPT to 1\/4 in FNPT Adapter\u003c\/li\u003e\n\u003cli\u003e1\/8 in FNPT to F-M20 Adapter\u003c\/li\u003e\n\u003cli\u003e1\/8 in FNPT to 1\/4 in FBSP Adapter\u003c\/li\u003e\n\u003cli\u003ePTFE Tape\u003c\/li\u003e\n\u003cli\u003e2x Sintered Filters\u003c\/li\u003e\n\u003cli\u003eWater Trap Drain\u003c\/li\u003e\n\u003cli\u003eValve Tuning Hoses\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_729_Pressure_Calibrator.PDF?v=1587055921\" target=\"_blank\" title=\"Fluke 729 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 729 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2020-04-16T10:44:24-06:00","created_at":"2020-04-16T10:44:24-06:00","vendor":"Fluke","type":"Pressure Calibrators","tags":[],"price":1601807,"price_min":1601807,"price_max":1601807,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":31377040965705,"title":"0 - 30 PSI","option1":"0 - 30 PSI","option2":null,"option3":null,"sku":"FLU-729-30G-FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 729 Automatic Pressure Calibrator - 0 - 30 PSI","public_title":"0 - 30 PSI","options":["0 - 30 PSI"],"price":1601807,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969840330","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":31377040998473,"title":"0 - 150 PSI","option1":"0 - 150 PSI","option2":null,"option3":null,"sku":"FLU-729-150G-FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 729 Automatic Pressure Calibrator - 0 - 150 PSI","public_title":"0 - 150 PSI","options":["0 - 150 PSI"],"price":1601807,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969840323","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":31377041031241,"title":"0 - 300 PSI","option1":"0 - 300 PSI","option2":null,"option3":null,"sku":"FLU-729-300G-FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 729 Automatic Pressure Calibrator - 0 - 300 PSI","public_title":"0 - 300 PSI","options":["0 - 300 PSI"],"price":1601807,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969840316","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke729Pic.jpg?v=1587056327"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke729Pic.jpg?v=1587056327","options":["Pressure Range"],"media":[{"alt":null,"id":5973396848713,"position":1,"preview_image":{"aspect_ratio":0.765,"height":1000,"width":765,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke729Pic.jpg?v=1587056327"},"aspect_ratio":0.765,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke729Pic.jpg?v=1587056327","width":765}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe ideal portable pressure calibrator, the 729 allows you to simply type in a target pressure, and the calibrator will automatically pump to the desired set-point. Then, internal fine adjustment control automatically stabilizes the pressure at the requested value.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 729 can also automatically test multiple pressure test points and automatically document the results. Calibration is as easy as typing in the starting and ending pressure and the number of test points and tolerance level. The 729 does the rest.\u003c\/p\u003e\n\u003cp\u003eBuilt-in HART communication capabilities enable HART transmitter mA adjustments, light HART configuration and the ability to adjust to applied 0% and 100% values.\u003c\/p\u003e\n\u003cp\u003eUpload and manage documented calibration results with DPCTrack2™ Calibration Management Software, making it easy to manage your instrumentation, create scheduled tests and reports, and manage calibration data.\u003c\/p\u003e\n\u003cp\u003eWith three ranges to choose from, 30 psi (2 bar, 200 kPa), 150 psi (10 bar, 1 MPa) and 300 psi (20 bar, 2 MPa), Fluke 729 Automatic Pressure Calibrators are designed to perform when and where you need them.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic pressure generation and regulation to 300 psi\u003c\/li\u003e\n\u003cli\u003eEasily document the process using onboard test templates\u003c\/li\u003e\n\u003cli\u003eAutomatic internal fine-pressure adjustment\u003c\/li\u003e\n\u003cli\u003eMeasure, source and simulate 4 to 20 mA signals\u003c\/li\u003e\n\u003cli\u003e24V loop power for powering transmitters for tests\u003c\/li\u003e\n\u003cli\u003eBright dual\/triple-channel color graphical display\u003c\/li\u003e\n\u003cli\u003eHART communication for testing HART smart transmitters\u003c\/li\u003e\n\u003cli\u003eBuilt-in leak testing for verifying test setups for leakage\u003c\/li\u003e\n\u003cli\u003eRugged portable design with standard 3-year warranty\u003c\/li\u003e\n\u003cli\u003eFluke Connect® App compatibility\u003c\/li\u003e\n\u003cli\u003eMeasure temperature with optional 720RTD probe\u003c\/li\u003e\n\u003cli\u003eMeasure Vdc for testing 1 V dc to 5 V dc output transmitters\u003c\/li\u003e\n\u003cli\u003eCompatible with 700 Series and 750 Series pressure modules\u003c\/li\u003e\n\u003cli\u003eUpload documented test results to DPCTrack2™ Calibration Management Software\u003c\/li\u003e\n\u003cli\u003eInnovative semi-rigid carrying case designed for field work\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003eSee Resources for Product Datasheet\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCalibrator with Wireless Communication\u003c\/li\u003e\n\u003cli\u003eSoft Case\u003c\/li\u003e\n\u003cli\u003eStackable Test Leads\u003c\/li\u003e\n\u003cli\u003eAC280 Hook Clips\u003c\/li\u003e\n\u003cli\u003eAlligator Clips\u003c\/li\u003e\n\u003cli\u003eTest Probes\u003c\/li\u003e\n\u003cli\u003eMagnetic Hanger Kit\u003c\/li\u003e\n\u003cli\u003eCarrying Strap\u003c\/li\u003e\n\u003cli\u003eWireless Adapter\u003c\/li\u003e\n\u003cli\u003eQuick Start Guide\u003c\/li\u003e\n\u003cli\u003eSafety Sheet\u003c\/li\u003e\n\u003cli\u003ePower Supply\u003c\/li\u003e\n\u003cli\u003eRechargeable Battery (installed)\u003c\/li\u003e\n\u003cli\u003eHose Kit with PUsh Fit Adapters\u003c\/li\u003e\n\u003cli\u003eHanging Clip\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003cli\u003e1\/8 in FNPT to 1\/4 in FNPT Adapter\u003c\/li\u003e\n\u003cli\u003e1\/8 in FNPT to F-M20 Adapter\u003c\/li\u003e\n\u003cli\u003e1\/8 in FNPT to 1\/4 in FBSP Adapter\u003c\/li\u003e\n\u003cli\u003ePTFE Tape\u003c\/li\u003e\n\u003cli\u003e2x Sintered Filters\u003c\/li\u003e\n\u003cli\u003eWater Trap Drain\u003c\/li\u003e\n\u003cli\u003eValve Tuning Hoses\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_729_Pressure_Calibrator.PDF?v=1587055921\" target=\"_blank\" title=\"Fluke 729 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 729 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 729 Automatic Pressure Calibrator

Fluke 729 Automatic Pressure Calibrator

$16,018.07 CAD

The ideal portable pressure calibrator, the 729 allows you to simply type in a target pressure, and the calibrator will automatically pump to the desired set-point. Then, internal fine adjustment control automatically stabilizes the pressure at the requested value. The Fluke 729 can also automatically test multiple pressure test points and autom...


More Info
{"id":4423600701513,"title":"Fluke 830\/BT Laser Shaft Alignment Tool w\/ Bluetooth","handle":"fluke-830-laser-shaft-alignment-tool","description":"\u003cp\u003eThe Fluke 830 Laser Shaft Alignment Tool is the ideal test tool to precision-align rotating shafts in your facility. Unlike using the straightedge method or dial indicators the Fluke 830 performs the complicated alignment calculations for you, meaning you'll have the answers you need to quickly align your machine and get your plant up and running fast. An enhanced user interface provides easy to understand results that don't require extensive alignment knowledge and the unique \"All-in-One\" result screen that shows you both coupling results and feet corrections (vertical and horizontal) in real terms making it easy to take corrective action.\u003c\/p\u003e\n\u003cp\u003eSince machine downtime is costly, test repeatability is critical. The Fluke 830 uses a patented single laser precision alignment system that provides accurate and repeatable measurement results so you can be assured you're addressing misalignment problems properly.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes a unique “All-in-One” result screen that shows both coupling results and vertical and horizontal feet corrections, making it easy to take corrective action\u003c\/li\u003e\n\u003cli\u003eFeatures a dynamic machine tolerance check that provides continuous evaluation of alignment adjustments so you know when your machine is in the acceptable range\u003c\/li\u003e\n\u003cli\u003eOffers unique extend mode to handle gross misalignment by virtually increasing laser detector size\u003c\/li\u003e\n\u003cli\u003eProvides auto save and resume capability to ensure your data is there when you need it\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLaser Alignment Tool\u003c\/li\u003e\n\u003cli\u003eWireless Sensor with Dust Cap\u003c\/li\u003e\n\u003cli\u003ePrism with Dust Cap\u003c\/li\u003e\n\u003cli\u003e2 x Chain-Type Mounting Brackets with Support Posts\u003c\/li\u003e\n\u003cli\u003ePC Cable\u003c\/li\u003e\n\u003cli\u003eUSB Memory Stick\u003c\/li\u003e\n\u003cli\u003eUSB Cable for USB Memory Stick\u003c\/li\u003e\n\u003cli\u003eCleaning Cloth\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003cli\u003eAdapter\/Charger\u003c\/li\u003e\n\u003cli\u003eUSB Adapter\/Charger\u003c\/li\u003e\n\u003cli\u003eMicro USB Cable\u003c\/li\u003e\n\u003cli\u003eDocumentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_830_Laser_Shaft_Alignment_Tool_SPEC.pdf?v=1613701035\" target=\"_blank\" title=\"Fluke 830\/BT Laser Shaft Alignment Tool w\/ Bluetooth\" rel=\"noopener noreferrer\"\u003eFluke 830\/BT Laser Shaft Alignment Tool w\/ Bluetooth Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2020-04-15T10:09:58-06:00","created_at":"2020-04-15T10:13:31-06:00","vendor":"Fluke","type":"Shaft Alignment","tags":[],"price":1372000,"price_min":1372000,"price_max":1372000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":31373013155913,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-830\/BT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 830\/BT Laser Shaft Alignment Tool w\/ Bluetooth","public_title":null,"options":["Default Title"],"price":1372000,"weight":5897,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke830Pic1.jpg?v=1586976035"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke830Pic1.jpg?v=1586976035","options":["Title"],"media":[{"alt":null,"id":5967571091529,"position":1,"preview_image":{"aspect_ratio":1.0,"height":700,"width":700,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke830Pic1.jpg?v=1586976035"},"aspect_ratio":1.0,"height":700,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke830Pic1.jpg?v=1586976035","width":700}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe Fluke 830 Laser Shaft Alignment Tool is the ideal test tool to precision-align rotating shafts in your facility. Unlike using the straightedge method or dial indicators the Fluke 830 performs the complicated alignment calculations for you, meaning you'll have the answers you need to quickly align your machine and get your plant up and running fast. An enhanced user interface provides easy to understand results that don't require extensive alignment knowledge and the unique \"All-in-One\" result screen that shows you both coupling results and feet corrections (vertical and horizontal) in real terms making it easy to take corrective action.\u003c\/p\u003e\n\u003cp\u003eSince machine downtime is costly, test repeatability is critical. The Fluke 830 uses a patented single laser precision alignment system that provides accurate and repeatable measurement results so you can be assured you're addressing misalignment problems properly.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes a unique “All-in-One” result screen that shows both coupling results and vertical and horizontal feet corrections, making it easy to take corrective action\u003c\/li\u003e\n\u003cli\u003eFeatures a dynamic machine tolerance check that provides continuous evaluation of alignment adjustments so you know when your machine is in the acceptable range\u003c\/li\u003e\n\u003cli\u003eOffers unique extend mode to handle gross misalignment by virtually increasing laser detector size\u003c\/li\u003e\n\u003cli\u003eProvides auto save and resume capability to ensure your data is there when you need it\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLaser Alignment Tool\u003c\/li\u003e\n\u003cli\u003eWireless Sensor with Dust Cap\u003c\/li\u003e\n\u003cli\u003ePrism with Dust Cap\u003c\/li\u003e\n\u003cli\u003e2 x Chain-Type Mounting Brackets with Support Posts\u003c\/li\u003e\n\u003cli\u003ePC Cable\u003c\/li\u003e\n\u003cli\u003eUSB Memory Stick\u003c\/li\u003e\n\u003cli\u003eUSB Cable for USB Memory Stick\u003c\/li\u003e\n\u003cli\u003eCleaning Cloth\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003cli\u003eAdapter\/Charger\u003c\/li\u003e\n\u003cli\u003eUSB Adapter\/Charger\u003c\/li\u003e\n\u003cli\u003eMicro USB Cable\u003c\/li\u003e\n\u003cli\u003eDocumentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_830_Laser_Shaft_Alignment_Tool_SPEC.pdf?v=1613701035\" target=\"_blank\" title=\"Fluke 830\/BT Laser Shaft Alignment Tool w\/ Bluetooth\" rel=\"noopener noreferrer\"\u003eFluke 830\/BT Laser Shaft Alignment Tool w\/ Bluetooth Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 830/BT Laser Shaft Alignment Tool w/ Bluetooth

Fluke 830/BT Laser Shaft Alignment Tool w/ Bluetooth

$13,720.00 CAD

The Fluke 830 Laser Shaft Alignment Tool is the ideal test tool to precision-align rotating shafts in your facility. Unlike using the straightedge method or dial indicators the Fluke 830 performs the complicated alignment calculations for you, meaning you'll have the answers you need to quickly align your machine and get your plant up and runnin...


More Info
Fluke PACK30 Professional Tools Backpack

Accessories Electrical

$319.59 CAD
{"id":4112233005099,"title":"Fluke PACK30 Professional Tools Backpack","handle":"fluke-pack30-professional-tools-backpack","description":"\u003cp\u003e\u003cstrong\u003eWhat you need. Where you need it\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBackpacks offer a convenient method for organizing, storing and your carrying tools. Keeping all the tools you need in a single Fluke Pack30 means fewer trips back to the truck. Plus, the Fluke Pack30 gives you a more comfortable solution than traditional tool belts that put all the weight on your lower back, or tool bags with awkward carrying straps. The Fluke Pack30 is a great solution for the electrician on the go!\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDesigned for professional electricians\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eOver 30 pockets in six main storage compartments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRugged, waterproof bottom base protects tools, keeping the backpack upright for easy access to tools\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eClips, brackets and straps on the outside of the Fluke Pack30 for frequently used tools such as tape rolls, measuring tapes, voltage detectors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStores, organizes and protects test equipment, hand tools, safety glasses, and personal items like keys, wallet and phone\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSpecial pocket for tablet PCs and laptops 12 inches (30 cm) wide or smaller\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilt with durable high-quality polyester and plastic bottom base\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMolded EVA covers for the front and top sections for added protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePadding in the back for comfort and lumbar support\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdjustable chest strap for even weight distribution and increased comfort\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStandard one-year warranty; extendable to 2 years through product registration within 45 days of purchase *\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"1\" bordercolor=\"#c5cdd2\" cellpadding=\"4\" cellspacing=\"0\" width=\"650\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e20 in x 13 in x 9.25 in (50.8 cm x 33 cm x 23.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eNet weight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e5 pounds (2.26 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage compartments\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 central storage compartment\u003cbr\u003e1 front compartment\u003cbr\u003e2 side compartments\u003cbr\u003e1 top compartment\u003cbr\u003e1 12 inch (30 cm) back pocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003csmall\u003eTools shown not included with the Fluke Pack30\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke PACK30 Backpack\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e","published_at":"2019-09-19T11:13:46-06:00","created_at":"2019-09-19T11:19:49-06:00","vendor":"Fluke","type":"Accessories Electrical","tags":[],"price":31959,"price_min":31959,"price_max":31959,"available":true,"price_varies":false,"compare_at_price":28200,"compare_at_price_min":28200,"compare_at_price_max":28200,"compare_at_price_varies":false,"variants":[{"id":30151541129259,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-PACK30","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke PACK30 Professional Tools Backpack","public_title":null,"options":["Default Title"],"price":31959,"weight":1361,"compare_at_price":28200,"inventory_management":"shopify","barcode":"095969870092","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_PACK30_Pic_1_c0abcdc4-ec4f-46f8-87c6-89af1f458c4c.jpg?v=1568913593","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_PACK30_Pic_2.jpg?v=1568913595","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_PACK30_Pic_3.jpg?v=1568913597","\/\/kingswayinstruments.com\/cdn\/shop\/products\/FLUKE_PACK30_Pic_4_c377c6ed-7cf8-4535-82bb-79c1f09be6a5.png?v=1568913599"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_PACK30_Pic_1_c0abcdc4-ec4f-46f8-87c6-89af1f458c4c.jpg?v=1568913593","options":["Title"],"media":[{"alt":null,"id":193006108715,"position":1,"preview_image":{"aspect_ratio":1.5,"height":1000,"width":1500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_PACK30_Pic_1_c0abcdc4-ec4f-46f8-87c6-89af1f458c4c.jpg?v=1568913593"},"aspect_ratio":1.5,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_PACK30_Pic_1_c0abcdc4-ec4f-46f8-87c6-89af1f458c4c.jpg?v=1568913593","width":1500},{"alt":null,"id":193006141483,"position":2,"preview_image":{"aspect_ratio":0.906,"height":1500,"width":1359,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_PACK30_Pic_2.jpg?v=1568913595"},"aspect_ratio":0.906,"height":1500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_PACK30_Pic_2.jpg?v=1568913595","width":1359},{"alt":null,"id":193006305323,"position":3,"preview_image":{"aspect_ratio":0.59,"height":1500,"width":885,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_PACK30_Pic_3.jpg?v=1568913597"},"aspect_ratio":0.59,"height":1500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_PACK30_Pic_3.jpg?v=1568913597","width":885},{"alt":null,"id":193006338091,"position":4,"preview_image":{"aspect_ratio":1.048,"height":648,"width":679,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FLUKE_PACK30_Pic_4_c377c6ed-7cf8-4535-82bb-79c1f09be6a5.png?v=1568913599"},"aspect_ratio":1.048,"height":648,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FLUKE_PACK30_Pic_4_c377c6ed-7cf8-4535-82bb-79c1f09be6a5.png?v=1568913599","width":679}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cstrong\u003eWhat you need. Where you need it\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBackpacks offer a convenient method for organizing, storing and your carrying tools. Keeping all the tools you need in a single Fluke Pack30 means fewer trips back to the truck. Plus, the Fluke Pack30 gives you a more comfortable solution than traditional tool belts that put all the weight on your lower back, or tool bags with awkward carrying straps. The Fluke Pack30 is a great solution for the electrician on the go!\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDesigned for professional electricians\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eOver 30 pockets in six main storage compartments\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRugged, waterproof bottom base protects tools, keeping the backpack upright for easy access to tools\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eClips, brackets and straps on the outside of the Fluke Pack30 for frequently used tools such as tape rolls, measuring tapes, voltage detectors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStores, organizes and protects test equipment, hand tools, safety glasses, and personal items like keys, wallet and phone\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eSpecial pocket for tablet PCs and laptops 12 inches (30 cm) wide or smaller\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBuilt with durable high-quality polyester and plastic bottom base\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMolded EVA covers for the front and top sections for added protection\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePadding in the back for comfort and lumbar support\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAdjustable chest strap for even weight distribution and increased comfort\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eStandard one-year warranty; extendable to 2 years through product registration within 45 days of purchase *\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"1\" bordercolor=\"#c5cdd2\" cellpadding=\"4\" cellspacing=\"0\" width=\"650\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e20 in x 13 in x 9.25 in (50.8 cm x 33 cm x 23.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eNet weight\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e5 pounds (2.26 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage compartments\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 central storage compartment\u003cbr\u003e1 front compartment\u003cbr\u003e2 side compartments\u003cbr\u003e1 top compartment\u003cbr\u003e1 12 inch (30 cm) back pocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003csmall\u003eTools shown not included with the Fluke Pack30\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke PACK30 Backpack\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e"}
Fluke PACK30 Professional Tools Backpack

Fluke PACK30 Professional Tools Backpack

$319.59 CAD

What you need. Where you need it Backpacks offer a convenient method for organizing, storing and your carrying tools. Keeping all the tools you need in a single Fluke Pack30 means fewer trips back to the truck. Plus, the Fluke Pack30 gives you a more comfortable solution than traditional tool belts that put all the weight on your lower back, or ...


More Info
Fluke PQ400 Electrical Measurement Window

Electrical Windows

From $2,919.91 CAD
{"id":1860000120875,"title":"Fluke PQ400 Electrical Measurement Window","handle":"fluke-pq400-electrical-measurement-window","description":"The Fluke PQ400 Electrical Measurement Window enables the connection of three phase measurement equipment to energized panels, without the need to open the panel door, or wear supplemental personal protective equipment.\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eReduced risk—Permanently installed voltage and current connections can be accessed without opening the panel door\u003c\/li\u003e\n\u003cli\u003eIncreased efficiency—Quickly connect your logger or analyzer and begin taking measurements faster than ever\u003c\/li\u003e\n\u003cli\u003eEasy installation—A standard step drill bit and electro-hydraulic hole punch provide the simple means to quickly mount the window in the panel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance without compromise. Safety without sacrifice.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke PQ400 gives you access to the critical power quality and energy data you need, all while decreasing testing time and helping you to maintain safety.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduce the risk of arc-flash and electrocution, while increasing the safety of your personnel\u003c\/li\u003e\n\u003cli\u003eDecrease maintenance costs and reduce downtime by making critical power quality and energy measurements without opening the panel door, enabling logging and monitoring at any time—without disrupting operations\u003c\/li\u003e\n\u003cli\u003eReduce work permit requirements and processes by reducing the hazards associated with taking measurements on open panels, saving time and effort\u003c\/li\u003e\n\u003cli\u003eIncrease measurement efficiency and reduce the need for arc-flash PPE\u003csup\u003e1\u003c\/sup\u003e, saving time, increasing efficiency and increasing operator comfort\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePermanently connected voltage and current sensors located inside the electrical panel allow you to make power quality and energy measurements using the external access points without opening the panel door, reducing operator risk\u003c\/li\u003e\n\u003cli\u003eVoltage and current connections for three-phase voltages, neutral and ground cover most measurement scenarios\u003c\/li\u003e\n\u003cli\u003eAutomatic probe detection for Fluke 1740 and 1730 series power quality and energy loggers and compatible clamps, eliminates the need to open cabinet to check the clamp model\u003c\/li\u003e\n\u003cli\u003eFull 360 degree rotation allows the PQ400 window to be oriented in any direction\u003c\/li\u003e\n\u003cli\u003eSimple installation using a step drill bit and electro-hydraulic hole punch (114.3 mm, 4.5 inch diameter)\u003c\/li\u003e\n\u003cli\u003eCAT IV, 600V and CATIII 1,000V rating according to IEC61010-2-30\u003c\/li\u003e\n\u003cli\u003eCompatibility with standard 4mm shrouded safety-socket voltage test leads makes it easier to make voltage connections, increases safety by reducing the risk of accidently touching live electrical components, and reduces the need for purchasing specialized voltage leads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHow it works\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke PQ400 Electrical Measurement Window is a permanently installed interface that provides technicians with near-instant access to electrical panels for making critical power quality and energy measurements. The PQ400 installs using a standard step drill bit and electro-hydraulic hole punch (114.3 mm, 4.5-inch hole diameter), and allows users to make three-phase voltage, current and ground connects covering most measurement configurations. Once installed, users can simply unlock the window cover, lift the lid, and connect the voltage leads of the logger or analyzer. Then, connect the leads for the current sensors and start making critical measurements. Once complete, simply remove the voltage and current connections from the front panel interface and lock the window lid, leaving the internal connections in place for future use.\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eGeneral specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any voltage terminal and earth ground\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any current terminal and earth ground\u003c\/td\u003e\n\u003ctd\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1: pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-2-030: CAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside\u003c\/td\u003e\n\u003ctd\u003e148 mm x 187 mm x 23 mm (W x H x D) (148 mm x 370 mm x 19 mm with cover opened)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInside\u003c\/td\u003e\n\u003ctd\u003e140 mm x 158 mm x Di (W x H x D) Di = 58 – thickness of panel door in mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eSupported electrical enclosures\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eUL 50\/NEMA environmental type 1 (Type 12 when PQ400 cover is closed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel thickness\u003c\/td\u003e\n\u003ctd\u003eMax. 3.5 mm (10 gauge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating\/storage temperature\u003c\/td\u003e\n\u003ctd\u003e-25 °C to 60 °C (-13 °F to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e10 % to 90 % in dependency of temperature according to IEC 60721-3-3 Class 3K6 (modified):-25 °C to 35 °C: 10 % to 90 %, 50°C: max. 35 %, 60°C: max. 23 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAltitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating\u003c\/td\u003e\n\u003ctd\u003e2,000 m (up to 4000 m derate to CAT II 1000 V, CAT III 600 V, CAT IV 300 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eIngress protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003eIEC 60529: IP67 with cover closed, IP50 with cover opened and all connectors attached\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2-6 , MIL-PRF28800F: Random vibration class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.1 kg (4.6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eVoltage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd\u003e5 (A\/L1, B\/L2, C\/L3, N, and earth\/ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire gauge\u003c\/td\u003e\n\u003ctd\u003eSolid\/flexible: 0.25 mm\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eto 1.5 mm\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e(AWG 24 to AWG 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003eMax. 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse\u003c\/td\u003e\n\u003ctd\u003e2 A 1000 V 1.5 A²s, 10 kA IR (A\/L1, B\/L2, C\/L3, N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003e5x 4 mm safety terminals, 3x red for A\/L1, B\/L2, C\/L3, 1x black for N, 1x green for earth\/ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad current\u003c\/td\u003e\n\u003ctd\u003eMax. 1 A rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eCurrent\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInput\/output\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003e5x 4-pin circular compatible with Fluke 354x FC, 173x, and 174x power and power quality loggers (these loggers can all be power from the measured voltage up to 500V)v\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"product-model\" itemprop=\"model\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/ProductModel\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\n\u003cp\u003eFLUKE-PQ400, Power Quality Window\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePQ400 enclosure\u003c\/li\u003e\n\u003cli\u003e4 x male-male cable 2m for connection of Fluke-17xx iFlex® current probes\u003c\/li\u003e\n\u003cli\u003eCable marker set 3P+N+PE\u003c\/li\u003e\n\u003cli\u003eCable ties\u003c\/li\u003e\n\u003cli\u003eInstruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-model\" itemprop=\"model\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/ProductModel\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\" itemprop=\"name\"\u003eFluke PQ400\/B\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\n\u003cp\u003eFLUKE-PQ400, Basic Power Quality Window\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePQ400 enclosure\u003c\/li\u003e\n\u003cli\u003eInstruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_PQ400.pdf?1717\" target=\"_blank\" title=\"Fluke PQ400 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke PQ400 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-08-19T09:55:40-06:00","created_at":"2019-08-19T10:03:30-06:00","vendor":"Fluke","type":"Electrical Windows","tags":[],"price":291991,"price_min":291991,"price_max":370191,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":17028668489771,"title":"FLU-PQ400","option1":"FLU-PQ400","option2":null,"option3":null,"sku":"FLU-PQ400","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke PQ400 Electrical Measurement Window - FLU-PQ400","public_title":"FLU-PQ400","options":["FLU-PQ400"],"price":370191,"weight":2722,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":17028668522539,"title":"FLU-PQ400\/B","option1":"FLU-PQ400\/B","option2":null,"option3":null,"sku":"FLU-PQ400\/B","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke PQ400 Electrical Measurement Window - FLU-PQ400\/B","public_title":"FLU-PQ400\/B","options":["FLU-PQ400\/B"],"price":291991,"weight":2722,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_PQ400.jpg?v=1566235232","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_PQ400_Pic_2.jpg?v=1566235247"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_PQ400.jpg?v=1566235232","options":["Model"],"media":[{"alt":null,"id":2823827718187,"position":1,"preview_image":{"aspect_ratio":1.657,"height":289,"width":479,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_PQ400.jpg?v=1566235232"},"aspect_ratio":1.657,"height":289,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_PQ400.jpg?v=1566235232","width":479},{"alt":null,"id":2823847673899,"position":2,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_PQ400_Pic_2.jpg?v=1566235247"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_PQ400_Pic_2.jpg?v=1566235247","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"The Fluke PQ400 Electrical Measurement Window enables the connection of three phase measurement equipment to energized panels, without the need to open the panel door, or wear supplemental personal protective equipment.\u003cbr\u003e\n\u003cul\u003e\n\u003cli\u003eReduced risk—Permanently installed voltage and current connections can be accessed without opening the panel door\u003c\/li\u003e\n\u003cli\u003eIncreased efficiency—Quickly connect your logger or analyzer and begin taking measurements faster than ever\u003c\/li\u003e\n\u003cli\u003eEasy installation—A standard step drill bit and electro-hydraulic hole punch provide the simple means to quickly mount the window in the panel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance without compromise. Safety without sacrifice.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke PQ400 gives you access to the critical power quality and energy data you need, all while decreasing testing time and helping you to maintain safety.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduce the risk of arc-flash and electrocution, while increasing the safety of your personnel\u003c\/li\u003e\n\u003cli\u003eDecrease maintenance costs and reduce downtime by making critical power quality and energy measurements without opening the panel door, enabling logging and monitoring at any time—without disrupting operations\u003c\/li\u003e\n\u003cli\u003eReduce work permit requirements and processes by reducing the hazards associated with taking measurements on open panels, saving time and effort\u003c\/li\u003e\n\u003cli\u003eIncrease measurement efficiency and reduce the need for arc-flash PPE\u003csup\u003e1\u003c\/sup\u003e, saving time, increasing efficiency and increasing operator comfort\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePermanently connected voltage and current sensors located inside the electrical panel allow you to make power quality and energy measurements using the external access points without opening the panel door, reducing operator risk\u003c\/li\u003e\n\u003cli\u003eVoltage and current connections for three-phase voltages, neutral and ground cover most measurement scenarios\u003c\/li\u003e\n\u003cli\u003eAutomatic probe detection for Fluke 1740 and 1730 series power quality and energy loggers and compatible clamps, eliminates the need to open cabinet to check the clamp model\u003c\/li\u003e\n\u003cli\u003eFull 360 degree rotation allows the PQ400 window to be oriented in any direction\u003c\/li\u003e\n\u003cli\u003eSimple installation using a step drill bit and electro-hydraulic hole punch (114.3 mm, 4.5 inch diameter)\u003c\/li\u003e\n\u003cli\u003eCAT IV, 600V and CATIII 1,000V rating according to IEC61010-2-30\u003c\/li\u003e\n\u003cli\u003eCompatibility with standard 4mm shrouded safety-socket voltage test leads makes it easier to make voltage connections, increases safety by reducing the risk of accidently touching live electrical components, and reduces the need for purchasing specialized voltage leads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHow it works\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke PQ400 Electrical Measurement Window is a permanently installed interface that provides technicians with near-instant access to electrical panels for making critical power quality and energy measurements. The PQ400 installs using a standard step drill bit and electro-hydraulic hole punch (114.3 mm, 4.5-inch hole diameter), and allows users to make three-phase voltage, current and ground connects covering most measurement configurations. Once installed, users can simply unlock the window cover, lift the lid, and connect the voltage leads of the logger or analyzer. Then, connect the leads for the current sensors and start making critical measurements. Once complete, simply remove the voltage and current connections from the front panel interface and lock the window lid, leaving the internal connections in place for future use.\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eGeneral specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any voltage terminal and earth ground\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any current terminal and earth ground\u003c\/td\u003e\n\u003ctd\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1: pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-2-030: CAT IV 600 V \/ CAT III 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutside\u003c\/td\u003e\n\u003ctd\u003e148 mm x 187 mm x 23 mm (W x H x D) (148 mm x 370 mm x 19 mm with cover opened)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInside\u003c\/td\u003e\n\u003ctd\u003e140 mm x 158 mm x Di (W x H x D) Di = 58 – thickness of panel door in mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eSupported electrical enclosures\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eUL 50\/NEMA environmental type 1 (Type 12 when PQ400 cover is closed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel thickness\u003c\/td\u003e\n\u003ctd\u003eMax. 3.5 mm (10 gauge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating\/storage temperature\u003c\/td\u003e\n\u003ctd\u003e-25 °C to 60 °C (-13 °F to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e10 % to 90 % in dependency of temperature according to IEC 60721-3-3 Class 3K6 (modified):-25 °C to 35 °C: 10 % to 90 %, 50°C: max. 35 %, 60°C: max. 23 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAltitude\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating\u003c\/td\u003e\n\u003ctd\u003e2,000 m (up to 4000 m derate to CAT II 1000 V, CAT III 600 V, CAT IV 300 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eIngress protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003eIEC 60529: IP67 with cover closed, IP50 with cover opened and all connectors attached\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2-6 , MIL-PRF28800F: Random vibration class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.1 kg (4.6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eVoltage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of inputs\u003c\/td\u003e\n\u003ctd\u003e5 (A\/L1, B\/L2, C\/L3, N, and earth\/ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire gauge\u003c\/td\u003e\n\u003ctd\u003eSolid\/flexible: 0.25 mm\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eto 1.5 mm\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e(AWG 24 to AWG 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003eMax. 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse\u003c\/td\u003e\n\u003ctd\u003e2 A 1000 V 1.5 A²s, 10 kA IR (A\/L1, B\/L2, C\/L3, N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003e5x 4 mm safety terminals, 3x red for A\/L1, B\/L2, C\/L3, 1x black for N, 1x green for earth\/ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad current\u003c\/td\u003e\n\u003ctd\u003eMax. 1 A rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eCurrent\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInput\/output\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003e5x 4-pin circular compatible with Fluke 354x FC, 173x, and 174x power and power quality loggers (these loggers can all be power from the measured voltage up to 500V)v\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"product-model\" itemprop=\"model\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/ProductModel\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\n\u003cp\u003eFLUKE-PQ400, Power Quality Window\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePQ400 enclosure\u003c\/li\u003e\n\u003cli\u003e4 x male-male cable 2m for connection of Fluke-17xx iFlex® current probes\u003c\/li\u003e\n\u003cli\u003eCable marker set 3P+N+PE\u003c\/li\u003e\n\u003cli\u003eCable ties\u003c\/li\u003e\n\u003cli\u003eInstruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-model\" itemprop=\"model\" itemscope=\"\" itemtype=\"https:\/\/schema.org\/ProductModel\"\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\" itemprop=\"name\"\u003eFluke PQ400\/B\u003cspan class=\"fluke-icon fluke-icon-caret-down\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\n\u003cp\u003eFLUKE-PQ400, Basic Power Quality Window\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePQ400 enclosure\u003c\/li\u003e\n\u003cli\u003eInstruction sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_PQ400.pdf?1717\" target=\"_blank\" title=\"Fluke PQ400 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke PQ400 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke PQ400 Electrical Measurement Window

Fluke PQ400 Electrical Measurement Window

$2,919.91 CAD

The Fluke PQ400 Electrical Measurement Window enables the connection of three phase measurement equipment to energized panels, without the need to open the panel door, or wear supplemental personal protective equipment. Reduced risk—Permanently installed voltage and current connections can be accessed without opening the panel door Increased ef...


More Info
Fluke ii900 Sonic Industrial Imager

Leak Detection

$31,755.99 CAD
{"id":1859995140139,"title":"Fluke ii900 Sonic Industrial Imager","handle":"fluke-ii900-sonic-industrial-imager","description":"\u003ch2 style=\"text-align: center;\"\u003e\u003cspan\u003e*AVAILABLE FOR RENT - Call us for more information*\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eEquipped with an array of microphones for an expanded field-of-view, the handheld Fluke ii900 Sonic Industrial Imager enables maintenance teams to quickly and accurately locate air, gas and vacuum leaks in compressed air systems; even in noisy environments. Specifically designed for noisy production facilities the new SoundSight™ technology is simple to learn and easy to implement. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 7” LCD touchscreen overlays a SoundMap™ on a visual image for quick leak location identification. The straightforward, intuitive interface allows technicians to isolate the sound frequency of the leak to filter out loud background noise. In a matter of hours, the team can inspect the entire plant – during peak operations. For the first time, you can quickly and easily identify the air leak repairs needed to ensure efficient operations and reduce utility bills. Images can be saved and exported for reporting purposes. Never leave air leaks unattended again.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/6xzVwLdnFhE?start=12\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDo more with the same air compressors – delay the capital expense of purchasing an additional compressor\u003c\/li\u003e\n\u003cli\u003eEnsure proper air pressure to your pneumatic equipment\u003c\/li\u003e\n\u003cli\u003eLower utility costs\u003c\/li\u003e\n\u003cli\u003eReduce leak detection time\u003c\/li\u003e\n\u003cli\u003eImprove reliability in your production line\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSensors\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of microphones\u003c\/td\u003e\n\u003ctd\u003e64 digital MEMS microphones\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency band\u003c\/td\u003e\n\u003ctd\u003e2 kHz to 52 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound pressure sensitivity\u003c\/td\u003e\n\u003ctd\u003eDetects a 0.005 CFM leak at 100PSI from up to 32.8 feet\u003cbr\u003e(Detects a 2.5 cm\u003csup\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/sup\u003e\/sec leak at 7 bar from up to 10 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation distance range\u003c\/td\u003e\n\u003ctd\u003e0.5 to \u0026gt; 50 meters (1.6 to \u0026gt; 164 feet)*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of View\u003c\/td\u003e\n\u003ctd\u003e63 ° ± 5 °\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Frame Rate\u003c\/td\u003e\n\u003ctd\u003e12.5 FPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003csmall\u003e\u003cem\u003e*Depending on ambient conditions\u003c\/em\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eBuilt-in digital camera (visible light)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of View (FOV)\u003c\/td\u003e\n\u003ctd\u003e63 ° ± 5 °\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFocus\u003c\/td\u003e\n\u003ctd\u003eFixed lens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003cth\u003e7\" LCD with backlight, under-sunlight readable\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1280 x 800 (1,024,000 pixels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen\u003c\/td\u003e\n\u003ctd\u003eCapacitive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcoustic Image\u003c\/td\u003e\n\u003ctd\u003eYes, SoundMap™ image\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eImage storage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage capacity\u003c\/td\u003e\n\u003ctd\u003eInternal memory with the capacity for 999 picture files or 20 video files\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage format\u003c\/td\u003e\n\u003ctd\u003eBlended visual and SoundMap™.JPG or .PNG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVideo format\u003c\/td\u003e\n\u003ctd\u003eBlended visual and SoundMap™.MP4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVideo length\u003c\/td\u003e\n\u003ctd\u003e30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital export\u003c\/td\u003e\n\u003ctd\u003eUSB-C for data transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eAcoustic Measurements\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e29.3 dB to 119.6 dB SPL (±2 dB) at 2 kHz\u003cbr\u003e21.9 dB to 112.3 db SPL (±2 dB) at 19 kHz\u003cbr\u003e36.6 db to 126.9 dB SPL (±2 dB) at 52 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto max\/min dB gain\u003c\/td\u003e\n\u003ctd\u003eAuto or manual, user selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency band selection\u003c\/td\u003e\n\u003ctd\u003eUser selectable through user-made presets or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSoftware\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEase of use\u003c\/td\u003e\n\u003ctd\u003eIntuitive user interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrend graphs\u003c\/td\u003e\n\u003ctd\u003eFrequency and dB scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpot markers\u003c\/td\u003e\n\u003ctd\u003edB level reading at center point of the image\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eBattery\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries (field-replaceable, rechargeable)\u003c\/td\u003e\n\u003ctd\u003eRechargeable Li-ion, Fluke BP291\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e6 hours (product includes spare battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charging time\u003c\/td\u003e\n\u003ctd\u003e3 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charging system\u003c\/td\u003e\n\u003ctd\u003eExternal dual-bay charger, EDBC 290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eGeneral Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard palettes\u003c\/td\u003e\n\u003ctd\u003e3: Grayscale, Ironbow, Blue-Red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C (32 °F to 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 °C to 70 °C (-4 °F to 158 °F) Without batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e10 % to 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd\u003e186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (battery included)\u003c\/td\u003e\n\u003ctd\u003e1.7 kg (3.75 pounds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain unit rating\u003c\/td\u003e\n\u003ctd\u003eIP40 protection against particles 1mm or greater and dripping water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor head rating\u003c\/td\u003e\n\u003ctd\u003eIP51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf-diagnostic notification\u003c\/td\u003e\n\u003ctd\u003eArray-health test to identify when microphone array needs attention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported languages\u003c\/td\u003e\n\u003ctd\u003eDutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS compliant\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSafety\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Safety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility (EMC) International\u003c\/td\u003e\n\u003ctd\u003eIEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2\u003cbr\u003eCISPR 11: Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eImager\u003c\/li\u003e\n\u003cli\u003eAC power supply and battery pack charger (including universal AC adapters)\u003c\/li\u003e\n\u003cli\u003eTwo rugged lithium ion smart battery packs\u003c\/li\u003e\n\u003cli\u003eUSB cable\u003c\/li\u003e\n\u003cli\u003eRugged, hard carrying case\u003c\/li\u003e\n\u003cli\u003eAdjustable hand strap and neck strap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/ii900_Data_Sheet.pdf?1716\" title=\"Fluke ii900 Spec Sheet\" target=\"_blank\"\u003eFluke ii900 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-08-19T09:43:37-06:00","created_at":"2019-08-19T09:46:24-06:00","vendor":"Fluke","type":"Leak Detection","tags":[],"price":3175599,"price_min":3175599,"price_max":3175599,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":17028547280939,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-ii900","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke ii900 Sonic Industrial Imager","public_title":null,"options":["Default Title"],"price":3175599,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969906371","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_ii900.jpg?v=1566229587","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_ii900_Pic_2.jpg?v=1566234936"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_ii900.jpg?v=1566229587","options":["Title"],"media":[{"alt":null,"id":2823824310315,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_ii900.jpg?v=1566229587"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_ii900.jpg?v=1566229587","width":1024},{"alt":null,"id":2823845380139,"position":2,"preview_image":{"aspect_ratio":1.503,"height":183,"width":275,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_ii900_Pic_2.jpg?v=1566234936"},"aspect_ratio":1.503,"height":183,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_ii900_Pic_2.jpg?v=1566234936","width":275},{"alt":null,"id":21493936259262,"position":3,"preview_image":{"aspect_ratio":1.333,"height":360,"width":480,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/hqdefault.jpg?v=1626099235"},"aspect_ratio":1.77,"external_id":"6xzVwLdnFhE","host":"youtube","media_type":"external_video"}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch2 style=\"text-align: center;\"\u003e\u003cspan\u003e*AVAILABLE FOR RENT - Call us for more information*\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eEquipped with an array of microphones for an expanded field-of-view, the handheld Fluke ii900 Sonic Industrial Imager enables maintenance teams to quickly and accurately locate air, gas and vacuum leaks in compressed air systems; even in noisy environments. Specifically designed for noisy production facilities the new SoundSight™ technology is simple to learn and easy to implement. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe 7” LCD touchscreen overlays a SoundMap™ on a visual image for quick leak location identification. The straightforward, intuitive interface allows technicians to isolate the sound frequency of the leak to filter out loud background noise. In a matter of hours, the team can inspect the entire plant – during peak operations. For the first time, you can quickly and easily identify the air leak repairs needed to ensure efficient operations and reduce utility bills. Images can be saved and exported for reporting purposes. Never leave air leaks unattended again.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/6xzVwLdnFhE?start=12\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDo more with the same air compressors – delay the capital expense of purchasing an additional compressor\u003c\/li\u003e\n\u003cli\u003eEnsure proper air pressure to your pneumatic equipment\u003c\/li\u003e\n\u003cli\u003eLower utility costs\u003c\/li\u003e\n\u003cli\u003eReduce leak detection time\u003c\/li\u003e\n\u003cli\u003eImprove reliability in your production line\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSensors\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of microphones\u003c\/td\u003e\n\u003ctd\u003e64 digital MEMS microphones\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency band\u003c\/td\u003e\n\u003ctd\u003e2 kHz to 52 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound pressure sensitivity\u003c\/td\u003e\n\u003ctd\u003eDetects a 0.005 CFM leak at 100PSI from up to 32.8 feet\u003cbr\u003e(Detects a 2.5 cm\u003csup\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/sup\u003e\/sec leak at 7 bar from up to 10 meters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation distance range\u003c\/td\u003e\n\u003ctd\u003e0.5 to \u0026gt; 50 meters (1.6 to \u0026gt; 164 feet)*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of View\u003c\/td\u003e\n\u003ctd\u003e63 ° ± 5 °\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Frame Rate\u003c\/td\u003e\n\u003ctd\u003e12.5 FPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003csmall\u003e\u003cem\u003e*Depending on ambient conditions\u003c\/em\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eBuilt-in digital camera (visible light)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of View (FOV)\u003c\/td\u003e\n\u003ctd\u003e63 ° ± 5 °\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFocus\u003c\/td\u003e\n\u003ctd\u003eFixed lens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003cth\u003e7\" LCD with backlight, under-sunlight readable\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1280 x 800 (1,024,000 pixels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen\u003c\/td\u003e\n\u003ctd\u003eCapacitive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcoustic Image\u003c\/td\u003e\n\u003ctd\u003eYes, SoundMap™ image\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eImage storage\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage capacity\u003c\/td\u003e\n\u003ctd\u003eInternal memory with the capacity for 999 picture files or 20 video files\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage format\u003c\/td\u003e\n\u003ctd\u003eBlended visual and SoundMap™.JPG or .PNG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVideo format\u003c\/td\u003e\n\u003ctd\u003eBlended visual and SoundMap™.MP4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVideo length\u003c\/td\u003e\n\u003ctd\u003e30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital export\u003c\/td\u003e\n\u003ctd\u003eUSB-C for data transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eAcoustic Measurements\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e29.3 dB to 119.6 dB SPL (±2 dB) at 2 kHz\u003cbr\u003e21.9 dB to 112.3 db SPL (±2 dB) at 19 kHz\u003cbr\u003e36.6 db to 126.9 dB SPL (±2 dB) at 52 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto max\/min dB gain\u003c\/td\u003e\n\u003ctd\u003eAuto or manual, user selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency band selection\u003c\/td\u003e\n\u003ctd\u003eUser selectable through user-made presets or manual entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSoftware\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEase of use\u003c\/td\u003e\n\u003ctd\u003eIntuitive user interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrend graphs\u003c\/td\u003e\n\u003ctd\u003eFrequency and dB scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpot markers\u003c\/td\u003e\n\u003ctd\u003edB level reading at center point of the image\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eBattery\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries (field-replaceable, rechargeable)\u003c\/td\u003e\n\u003ctd\u003eRechargeable Li-ion, Fluke BP291\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e6 hours (product includes spare battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charging time\u003c\/td\u003e\n\u003ctd\u003e3 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charging system\u003c\/td\u003e\n\u003ctd\u003eExternal dual-bay charger, EDBC 290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eGeneral Specifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard palettes\u003c\/td\u003e\n\u003ctd\u003e3: Grayscale, Ironbow, Blue-Red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to 40 °C (32 °F to 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 °C to 70 °C (-4 °F to 158 °F) Without batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e10 % to 95 % non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd\u003e186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (battery included)\u003c\/td\u003e\n\u003ctd\u003e1.7 kg (3.75 pounds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain unit rating\u003c\/td\u003e\n\u003ctd\u003eIP40 protection against particles 1mm or greater and dripping water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor head rating\u003c\/td\u003e\n\u003ctd\u003eIP51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf-diagnostic notification\u003c\/td\u003e\n\u003ctd\u003eArray-health test to identify when microphone array needs attention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported languages\u003c\/td\u003e\n\u003ctd\u003eDutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS compliant\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eSafety\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Safety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility (EMC) International\u003c\/td\u003e\n\u003ctd\u003eIEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2\u003cbr\u003eCISPR 11: Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eImager\u003c\/li\u003e\n\u003cli\u003eAC power supply and battery pack charger (including universal AC adapters)\u003c\/li\u003e\n\u003cli\u003eTwo rugged lithium ion smart battery packs\u003c\/li\u003e\n\u003cli\u003eUSB cable\u003c\/li\u003e\n\u003cli\u003eRugged, hard carrying case\u003c\/li\u003e\n\u003cli\u003eAdjustable hand strap and neck strap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/ii900_Data_Sheet.pdf?1716\" title=\"Fluke ii900 Spec Sheet\" target=\"_blank\"\u003eFluke ii900 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke ii900 Sonic Industrial Imager

Fluke ii900 Sonic Industrial Imager

$31,755.99 CAD

*AVAILABLE FOR RENT - Call us for more information* Equipped with an array of microphones for an expanded field-of-view, the handheld Fluke ii900 Sonic Industrial Imager enables maintenance teams to quickly and accurately locate air, gas and vacuum leaks in compressed air systems; even in noisy environments. Specifically designed for noisy produ...


More Info
{"id":1858235564075,"title":"Fluke T6-1000\/PRV240FS Electrical Tester with Proving Unit","handle":"fluke-t6-1000-prv240fs-electrical-tester-with-proving-unit","description":"\u003cp\u003eFluke Electrical Tester with FieldSense Plus PRV240FS Proving Unit, 1000V AC\/DC, 100A AC\u003cbr\u003eMeasure voltage to 1000 V ac through the open fork, without test leads\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eMeasure voltage up to 1000 V ac due to FieldSense technology, which easily and quickly takes measurements by sliding a conductor through the open fork. Additionally, without opening covers or removing wire nuts, on wires up to AWG 4\/0 (120 mm2), carrying as much as 200 A which makes the jobs safer, faster and easier.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage\u003c\/li\u003e\n\u003cli\u003eSimultaneous voltage and current display shows all power supply measurements at a glance for efficient troubleshooting\u003c\/li\u003e\n\u003cli\u003e1 to 1000 V ac or dc\u003c\/li\u003e\n\u003cli\u003e0.1 to 200 A ac\u003c\/li\u003e\n\u003cli\u003eResistance 1 Ω to 100 kΩ\u003c\/li\u003e\n\u003cli\u003eFrequency measurement 45 to 66 Hz\u003c\/li\u003e\n\u003cli\u003eWorks with wires up to AWG 4\/0 (120 mm2) with a 0.7\" (17.8 mm) jaw opening\u003c\/li\u003e\n\u003cli\u003eHold button temporarily freezes the reading for easy viewing\u003c\/li\u003e\n\u003cli\u003eEasy to read display with backlight\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke PRV240FS Proving Unit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReduces the need for personal protective equipment (PPE) when a known voltage source is not available for verification (PPE is still needed for absence of voltage testing when appropriate).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eSources both ac and dc steady-state voltage - supplies 240 V dc\/ac\u003c\/li\u003e\n\u003cli\u003eA single LED indicates functionality, making this unit a simple-to-use solution for verification of your test tool\u003c\/li\u003e\n\u003cli\u003eCompatible with both high impedance or low impedance multimeters, clamp meters or two pole testers\u003c\/li\u003e\n\u003cli\u003eVoltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact\u003c\/li\u003e\n\u003cli\u003eLong battery life - 5000 tests per set of four AA batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ch4\u003eFluke T6-1000\/PRV240FS Specifications\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFieldSense AC Voltage True RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(3% + 3 counts) 45 to 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFieldSense AC Current True RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e200.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(3% + 3 counts) 45 to 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFieldSense Frequency (Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e45 to 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVolts AC True RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 2 counts) 45 to 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVolts DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003cbr\u003e2000 Ω\u003cbr\u003e20 kΩ\u003cbr\u003e100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 V\u003cbr\u003e1 Ω\u003cbr\u003e0.01 kΩ\u003cbr\u003e0.1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V CAT III\u003cbr\u003e600 V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eOne year calibration cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd\u003e0.7\" (17.8 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e14 to 122°F (-10 to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-22 to 140°F (-30 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e6562' (2000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd\u003e32,808' (10,000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 90%, 41 to 86°F (5 to 30°C)\u003cbr\u003e0 to 75%, 86 to 104°F (30 to 40°C)\u003cbr\u003e0 to 45%, 104 to 122°F (40 to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type and Life\u003c\/td\u003e\n\u003ctd\u003e2 x AA (IEC LR6)\u003cbr\u003e360 hours continuous\u003cbr\u003eTypical; 200 hours using FieldSense\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.1 x (specified accuracy) \/°C for \u0026lt;18 or \u0026gt;28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61010-1: Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Environment\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61326-1: Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.4 x 10.2 x 1.7\" (61.1 x 259.3 x 43.8 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.78 lb (350 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eT6-1000 Electrical Teste\u003c\/li\u003e\n\u003cli\u003ePRV240FS Proving Unit\u003c\/li\u003e\n\u003cli\u003eAttached Test Leads, with 0.16\" (4 mm) Removable Probe Caps\u003c\/li\u003e\n\u003cli\u003eUser's Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e","published_at":"2019-08-16T10:18:39-06:00","created_at":"2019-08-16T10:24:07-06:00","vendor":"Fluke","type":"Multimeters","tags":[],"price":74799,"price_min":74799,"price_max":74799,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16996849385515,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-T6-1000\/PRV240FS","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke T6-1000\/PRV240FS Electrical Tester with Proving Unit","public_title":null,"options":["Default Title"],"price":74799,"weight":907,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969854177","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/T6-1000-PRV240FS.jpg?v=1565972650"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/T6-1000-PRV240FS.jpg?v=1565972650","options":["Title"],"media":[{"alt":null,"id":2822234832939,"position":1,"preview_image":{"aspect_ratio":0.73,"height":2000,"width":1460,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/T6-1000-PRV240FS.jpg?v=1565972650"},"aspect_ratio":0.73,"height":2000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/T6-1000-PRV240FS.jpg?v=1565972650","width":1460}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eFluke Electrical Tester with FieldSense Plus PRV240FS Proving Unit, 1000V AC\/DC, 100A AC\u003cbr\u003eMeasure voltage to 1000 V ac through the open fork, without test leads\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eMeasure voltage up to 1000 V ac due to FieldSense technology, which easily and quickly takes measurements by sliding a conductor through the open fork. Additionally, without opening covers or removing wire nuts, on wires up to AWG 4\/0 (120 mm2), carrying as much as 200 A which makes the jobs safer, faster and easier.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage\u003c\/li\u003e\n\u003cli\u003eSimultaneous voltage and current display shows all power supply measurements at a glance for efficient troubleshooting\u003c\/li\u003e\n\u003cli\u003e1 to 1000 V ac or dc\u003c\/li\u003e\n\u003cli\u003e0.1 to 200 A ac\u003c\/li\u003e\n\u003cli\u003eResistance 1 Ω to 100 kΩ\u003c\/li\u003e\n\u003cli\u003eFrequency measurement 45 to 66 Hz\u003c\/li\u003e\n\u003cli\u003eWorks with wires up to AWG 4\/0 (120 mm2) with a 0.7\" (17.8 mm) jaw opening\u003c\/li\u003e\n\u003cli\u003eHold button temporarily freezes the reading for easy viewing\u003c\/li\u003e\n\u003cli\u003eEasy to read display with backlight\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke PRV240FS Proving Unit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReduces the need for personal protective equipment (PPE) when a known voltage source is not available for verification (PPE is still needed for absence of voltage testing when appropriate).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eSources both ac and dc steady-state voltage - supplies 240 V dc\/ac\u003c\/li\u003e\n\u003cli\u003eA single LED indicates functionality, making this unit a simple-to-use solution for verification of your test tool\u003c\/li\u003e\n\u003cli\u003eCompatible with both high impedance or low impedance multimeters, clamp meters or two pole testers\u003c\/li\u003e\n\u003cli\u003eVoltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact\u003c\/li\u003e\n\u003cli\u003eLong battery life - 5000 tests per set of four AA batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ch4\u003eFluke T6-1000\/PRV240FS Specifications\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFieldSense AC Voltage True RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(3% + 3 counts) 45 to 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFieldSense AC Current True RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e200.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(3% + 3 counts) 45 to 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFieldSense Frequency (Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e45 to 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVolts AC True RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 2 counts) 45 to 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVolts DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003cbr\u003e2000 Ω\u003cbr\u003e20 kΩ\u003cbr\u003e100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 V\u003cbr\u003e1 Ω\u003cbr\u003e0.01 kΩ\u003cbr\u003e0.1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V CAT III\u003cbr\u003e600 V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eOne year calibration cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd\u003e0.7\" (17.8 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e14 to 122°F (-10 to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-22 to 140°F (-30 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e6562' (2000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd\u003e32,808' (10,000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 90%, 41 to 86°F (5 to 30°C)\u003cbr\u003e0 to 75%, 86 to 104°F (30 to 40°C)\u003cbr\u003e0 to 45%, 104 to 122°F (40 to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type and Life\u003c\/td\u003e\n\u003ctd\u003e2 x AA (IEC LR6)\u003cbr\u003e360 hours continuous\u003cbr\u003eTypical; 200 hours using FieldSense\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.1 x (specified accuracy) \/°C for \u0026lt;18 or \u0026gt;28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61010-1: Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Environment\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61326-1: Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.4 x 10.2 x 1.7\" (61.1 x 259.3 x 43.8 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.78 lb (350 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eT6-1000 Electrical Teste\u003c\/li\u003e\n\u003cli\u003ePRV240FS Proving Unit\u003c\/li\u003e\n\u003cli\u003eAttached Test Leads, with 0.16\" (4 mm) Removable Probe Caps\u003c\/li\u003e\n\u003cli\u003eUser's Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e"}
Fluke T6-1000/PRV240FS Electrical Tester with Proving Unit

Fluke T6-1000/PRV240FS Electrical Tester with Proving Unit

$747.99 CAD

Fluke Electrical Tester with FieldSense Plus PRV240FS Proving Unit, 1000V AC/DC, 100A ACMeasure voltage to 1000 V ac through the open fork, without test leads Overview Measure voltage up to 1000 V ac due to FieldSense technology, which easily and quickly takes measurements by sliding a conductor through the open fork. Additionally, without open...


More Info
Fluke T6-600 Electrical Tester

Multimeters

$342.49 CAD
{"id":1858230190123,"title":"Fluke T6-600 Electrical Tester","handle":"fluke-t6-600-electrical-tester","description":"\u003cp\u003e\u003cstrong\u003eMeasure voltage … without test leads\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe know working in electrical boxes jammed with wires can be challenging when you’re trying to find a safe metallic contact point. Now, with Fluke’s T6-600 or T6-1000 with integrated FieldSense technology, you can quickly and easily take measurements by sliding the open fork over a conductor to see the voltage level without the need for test leads.*\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e5 reasons the T6 belongs in your toolbelt\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eBe safer: Measure voltage to 600 V ac through the open fork, without test leads.\u003c\/li\u003e\n\u003cli\u003eBe faster: No need to open covers or remove wire nuts.\u003c\/li\u003e\n\u003cli\u003eBe more efficient: Simultaneously measure voltage and current.\u003c\/li\u003e\n\u003cli\u003eBe everywhere: 17.8 mm open fork is widest in the industry; measure up to 200 A on 4\/0 wires (120 mm\u003csup\u003e2\u003c\/sup\u003e).\u003c\/li\u003e\n\u003cli\u003eGo beyond simple detection. Actually measure ac voltage and current values without test leads.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Highlights\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage*\u003c\/li\u003e\n\u003cli\u003eSee voltage or current display – shows all power supply measurements at a glance for efficient trouble shooting\u003c\/li\u003e\n\u003cli\u003e1 to 600 V ac or dc (T6-600)\u003c\/li\u003e\n\u003cli\u003e0 to 200 A ac\u003c\/li\u003e\n\u003cli\u003eTrue-rms voltage and current\u003c\/li\u003e\n\u003cli\u003eResistance 1 Ω to 2000 Ω\u003c\/li\u003e\n\u003cli\u003eWorks with wires up to AWG 4\/0 (120 mm\u003csup\u003e2\u003c\/sup\u003e) with a 17.8 mm jaw opening\u003c\/li\u003e\n\u003cli\u003eHOLD button temporarily freezes the reading for easy viewing\u003c\/li\u003e\n\u003cli\u003eEasy to read display with backlight\u003c\/li\u003e\n\u003cli\u003eAccepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation\u003c\/li\u003e\n\u003cli\u003eStandard two-year warranty; extendable to 4 years through product registration within 45 days of purchase+\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ccaption\u003eMeasurement Specifications\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRequires test leads\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003csup\u003e[1]\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldSense\u003cbr\u003eac voltage true-rms\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e±(3% + 3 counts) 45 Hz - 66 Hz\u003csup\u003e[2] [3]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldSense\u003cbr\u003eac current true-rms\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e200.0 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±(3% + 3 counts) 45 Hz - 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldSense\u003cbr\u003efrequency (Hz)\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Hz\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003csup\u003e[3]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVolts ac true-rms\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 2 counts) 45 Hz - 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVolts dc\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003e1 Ω\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e600 V CAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp\u003eAccuracy\u003csup\u003e[1]\u003c\/sup\u003e: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.\u003c\/p\u003e\n\u003cp\u003eAccuracy\u003csup\u003e[2]\u003c\/sup\u003e: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.\u003c\/p\u003e\n\u003cp\u003eAccuracy\u003csup\u003e[3]\u003c\/sup\u003e: FieldSense is specified from 16 V to 100 % of range.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAttached test leads with removable 4 mm probe caps, user documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_T6_Electrical_Tester_Specs.PDF?1713\" target=\"_blank\" title=\"Fluke T6-600 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke T6-600 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-08-16T10:09:23-06:00","created_at":"2019-08-16T10:14:25-06:00","vendor":"Fluke","type":"Multimeters","tags":[],"price":34249,"price_min":34249,"price_max":34249,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16996781391915,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-T6-600","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke T6-600 Electrical Tester","public_title":null,"options":["Default Title"],"price":34249,"weight":907,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969854115","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/t6-600.jpg?v=1565972067"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/t6-600.jpg?v=1565972067","options":["Title"],"media":[{"alt":null,"id":2822229033003,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/t6-600.jpg?v=1565972067"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/t6-600.jpg?v=1565972067","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cstrong\u003eMeasure voltage … without test leads\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe know working in electrical boxes jammed with wires can be challenging when you’re trying to find a safe metallic contact point. Now, with Fluke’s T6-600 or T6-1000 with integrated FieldSense technology, you can quickly and easily take measurements by sliding the open fork over a conductor to see the voltage level without the need for test leads.*\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e5 reasons the T6 belongs in your toolbelt\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eBe safer: Measure voltage to 600 V ac through the open fork, without test leads.\u003c\/li\u003e\n\u003cli\u003eBe faster: No need to open covers or remove wire nuts.\u003c\/li\u003e\n\u003cli\u003eBe more efficient: Simultaneously measure voltage and current.\u003c\/li\u003e\n\u003cli\u003eBe everywhere: 17.8 mm open fork is widest in the industry; measure up to 200 A on 4\/0 wires (120 mm\u003csup\u003e2\u003c\/sup\u003e).\u003c\/li\u003e\n\u003cli\u003eGo beyond simple detection. Actually measure ac voltage and current values without test leads.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Highlights\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage*\u003c\/li\u003e\n\u003cli\u003eSee voltage or current display – shows all power supply measurements at a glance for efficient trouble shooting\u003c\/li\u003e\n\u003cli\u003e1 to 600 V ac or dc (T6-600)\u003c\/li\u003e\n\u003cli\u003e0 to 200 A ac\u003c\/li\u003e\n\u003cli\u003eTrue-rms voltage and current\u003c\/li\u003e\n\u003cli\u003eResistance 1 Ω to 2000 Ω\u003c\/li\u003e\n\u003cli\u003eWorks with wires up to AWG 4\/0 (120 mm\u003csup\u003e2\u003c\/sup\u003e) with a 17.8 mm jaw opening\u003c\/li\u003e\n\u003cli\u003eHOLD button temporarily freezes the reading for easy viewing\u003c\/li\u003e\n\u003cli\u003eEasy to read display with backlight\u003c\/li\u003e\n\u003cli\u003eAccepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation\u003c\/li\u003e\n\u003cli\u003eStandard two-year warranty; extendable to 4 years through product registration within 45 days of purchase+\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ccaption\u003eMeasurement Specifications\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRequires test leads\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eResolution\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003csup\u003e[1]\u003c\/sup\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldSense\u003cbr\u003eac voltage true-rms\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e±(3% + 3 counts) 45 Hz - 66 Hz\u003csup\u003e[2] [3]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldSense\u003cbr\u003eac current true-rms\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e200.0 A\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003ctd\u003e±(3% + 3 counts) 45 Hz - 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldSense\u003cbr\u003efrequency (Hz)\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Hz\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003csup\u003e[3]\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVolts ac true-rms\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 2 counts) 45 Hz - 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVolts dc\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e600 V\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResistance\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003e1 Ω\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e600 V CAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctfoot\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp\u003eAccuracy\u003csup\u003e[1]\u003c\/sup\u003e: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.\u003c\/p\u003e\n\u003cp\u003eAccuracy\u003csup\u003e[2]\u003c\/sup\u003e: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.\u003c\/p\u003e\n\u003cp\u003eAccuracy\u003csup\u003e[3]\u003c\/sup\u003e: FieldSense is specified from 16 V to 100 % of range.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tfoot\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAttached test leads with removable 4 mm probe caps, user documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_T6_Electrical_Tester_Specs.PDF?1713\" target=\"_blank\" title=\"Fluke T6-600 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke T6-600 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke T6-600 Electrical Tester

Fluke T6-600 Electrical Tester

$342.49 CAD

Measure voltage … without test leads We know working in electrical boxes jammed with wires can be challenging when you’re trying to find a safe metallic contact point. Now, with Fluke’s T6-600 or T6-1000 with integrated FieldSense technology, you can quickly and easily take measurements by sliding the open fork over a conductor to see the voltag...