Fluke 190 Series III ScopeMeter® Test Tools are engineered to go where you go, and tackle just about any troubleshooting job along the way. These CAT III 1000 V/CAT IV 600V rated test tools combine rugged portability with the high performance of bench oscilloscopes to help you take on the challenges of installing, commissioning and maintaining industrial machinery, automation and process controls, and power conversion electronics with ease—from DC to 500 MHz.
Choose from two or four channel models with a wide range of bandwidth options. Fast sampling rates up to 5.0 GS/s, 200 ps resolution and deep memory of 10,000 samples per channel allow high-accuracy capture and display of waveform details, noise, and other disturbances.
Perform timing or amplitude related measurements on three phases or three-axis control systems, or simply compare and contrast multiple test points in a circuit under test. Features like TrendPlot™ Paperless Recorder, ScopeRecord™ Mode, Connect-and-View™ Triggering and a unique 100-screen Replay function help you quickly diagnose issues to minimize repair costs and downtime. These features make the oscilloscopes easy to use especially when diagnosing the most difficult problems like complex waveforms, induced noise, intermittent events and signal fluctuations or drift.
Overview
- Up to four independent floating isolated inputs, up to 1000 V
- Up to 5 GS/s real time sampling (depending on model and channels used)
- Deep memory: 10,000 points per trace waveform capture (scope mode)
- CAT III 1000 V/CAT IV 600 V safety rated instrument for industrial environments
- Up to seven hours of battery operation using BP291
- Large, bright color display is easy to view in nearly any environment
- Easy to store and view historical data and transfer to a PC via USB or Wifi
- Convenient battery access door for quick battery swaps in the field
- IP51 rating, dust and drip-proof
- Connect-and-View triggering for intelligent, automatic triggering on fast, slow and even complex signals
- Frequency spectrum using FFT-analysis
- Automatic capture and REPLAY of 100 screens
- ScopeRecord mode gives 30,000 points per input channel for low frequency signal analysis
- TrendPlot Paperless Recorder mode with deep memory for long- term automatic measurements
- 5,000 count DMM included in the 2-channel models
Specifications
Oscilloscope Modes | |||||||
190-062 | 190-102 | 190-202 | 190-502 | 190-104 | 190-204 | 190-504 | |
Vertical deflection | |||||||
Number of channels | 2 | 2 | 2 | 2 | 4 | 4 | 4 |
Bandwidth | 60 MHz | 100 MHz | 200 MHz | 500 MHz | 100 MHz | 200 MHz | 500 MHz |
Rise time | 5.8 ns | 3.5 ns | 1.7 ns | 0.7 ns | 3.5 ns | 1.7 ns | 0.7 ns |
Number of scope inputs | 2 input channels plus external trigger | 4 input channels | |||||
Channel architecture | All inputs fully insulated from each other and from ground. Inputs may be activated in any combination. | ||||||
Input coupling | AC or DC, with ground level indicator | ||||||
Input sensitivity | With 10:1 probe, 20 mV to 1000 V/div With 100:1 probe, 200 mV to 10 kV/div Direct (1:1), 2 mV to 100 V/div |
||||||
Bandwidth limiter | 20 MHz and 10 kHz | ||||||
Polarity | Normal, Inverted, Variable | ||||||
Input voltage | CAT III 1000 V/CAT IV 600 V rated, see General specifications for further details | ||||||
Vertical resolution | 8 bit | ||||||
Accuracy at 4 s to 10 μs/div | 5 mV/div to 100 V/div, ±(1.5 % + 6 counts) 2 mV/div, ±(1.5 % + 10 counts) |
||||||
Input impedance | 1 MΩ (± 1 %) // 15 pF (± 2.25 pF) | ||||||
Horizontal | |||||||
Maximum real- time sample rate (sampled simultaneously) | 625 MS/s (each channel) |
1.25 GS/s (each channel) | 2.5 GS/s (each channel) | 5 GS/s (single channel) or 2.5 GS/s (dual channel) |
1.25 GS/s (each channel) | 2.5 GS/s (2ch) 1.25 GS/s (4ch) |
5 GS/s (single ch) or 2.5 GS/s (2ch) or 1.25 GS/s (4ch) |
Record length | Up to 10,000 samples per channel | ||||||
Time base range | 10 ns/div to 4 s/div |
5 ns/div to 4 s/div |
2 ns/div to 4 s/div |
1 ns/div to 4 s/div |
5 ns/div to 4 s/div |
2 ns/div to 4 s/div |
1 ns/div to 4 s/div |
Time base in a 1-2-4-sequence Slower time/division settings using ScopeRecord™ Roll mode (see ‘Recorder mode’) |
|||||||
Maximum record length | 10,000 samples per channel in scope mode 30,000 points per channel in ScopeRecord™ Roll mode (see ‘Recorder mode’) |
||||||
Timing accuracy | ± (0.01 % of reading + 1 pixel) | ||||||
Glitch capture | 8 ns (10 µs/div to 2 min/div) |
What's in the Box
- ScopeMeter Test Tool
- BC190/830 power adapter
- Power cord set
- BP291 Li-ion battery pack
- ** VPS410-II probe (4x)
- Hand strap
- Hanging strap
- USB-cable
- ** TRM50 cable terminator (4 pcs)
- ** CXT293 carrying case (Kit Only)
- ** DWA-131 WiFi dongle
- ** FlukeView Activation Software (Kit Only)
- Printed instructions
**Included items vary based on model selected