{ "id":1054995218475, "title":"Fluke 53 II Temperature Logging Digital Thermometer","handle":"fluke-53-ii-thermometer", "description":"\u003cp\u003e\u003cspan\u003eThe Fluke 53 II single input digital thermometer delivers fast response with laboratory accuracy (0.05% + 0.3°C). And it logs up to 500 points of temperature data to internal memory. You can use the 53 II to measure contact temperature on motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, E, N, R, or S-type thermocouple temperature sensors. The user-friendly-front panel and large, backlit display make it easy to view results and recall logged data for further review. And the sleep mode feature preserves battery life to give you a typical thousand hours of operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eSingle Input digital thermometer with data logging for lab, QA, process calibration, food safety and HVAC\u003c\/li\u003e\n\u003cli\u003eLogs up to 500 points of data at user adjustable recording intervals\u003c\/li\u003e\n\u003cli\u003eMeasures J, K, T, E, R, S, and N-type thermocouples\u003c\/li\u003e\n\u003cli\u003ePresents results in °C, °F, or Kelvin (K) on a large backlit display\u003c\/li\u003e\n\u003cli\u003eProvides a recall function to easily review logged data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eTemperature accuracy\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cb\u003eAbove -100°C\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eJ, K, T, E, and N-type: ±[0.05% + 0.3°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eR and S-type: ±[0.05% + 0.4°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cb\u003eBelow -100°C\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eJ, K, E, and N-types: ±[0.20% + 0.3°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eT-type: ±[0.50% + 0.3°C]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eJ-type:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-210°C to 1200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-type\u003c\/td\u003e\n\u003ctd\u003e-200°C to 1372°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT-type\u003c\/td\u003e\n\u003ctd\u003e-250°C to 400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-type\u003c\/td\u003e\n\u003ctd\u003e-150°C to 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN-type\u003c\/td\u003e\n\u003ctd\u003e-200°C to 1300°C\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR and S-type\u003c\/td\u003e\n\u003ctd\u003e0°C to 1767°C\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature scale\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eITS-90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable standards\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNIST-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C, 0.1 K \u0026lt; 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1°C, 1 K ≥ 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"3\"\u003e1. Only the Fluke Models 53 II B and 54 II Bthermometers are capable of measuring N, R, and S-type thermocouples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% to 90%; 0°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 70%; 0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCE, CSA, TÜV (pending)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e173 x 86 x 38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 AA batteries; typical 1000-hour life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpact absorbing holster\u003c\/li\u003e\n\u003cli\u003eOne 80PK-1 bead probe thermocouple\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_50_Series_Thermometer.pdf?1832\" target=\"_blank\" title=\"Fluke 53 IIB Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 53 IIB Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-02-27T16:29:34", "created_at":"2018-02-27T16:37:09", "vendor":"Fluke", "type":"Digital Thermometers", "tags":[], "price":81599, "price_min":81599, "price_max":81599, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[10861565870123], "variants":[{ "id":10861565870123, "product_id":1054995218475, "product_handle":"fluke-53-ii-thermometer", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"FLU-53-2-B", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 53 II Temperature Logging Digital Thermometer - Default Title", "options":["Default Title"], "price":81599, "weight":2268, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969565103"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/FLU_53_II_B-50Hz.jpg?v=1519774631","\/\/kingswayinstruments.com\/cdn\/shop\/products\/81RP-hJFuPL._SL1500.jpg?v=1519774632"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FLU_53_II_B-50Hz.jpg?v=1519774631", "options":["Title"], "url":"\/products\/fluke-53-ii-thermometer"}

Fluke 53 II Temperature Logging Digital Thermometer

Product Description

The Fluke 53 II single input digital thermometer delivers fast response with laboratory accuracy (0.05% + 0.3°C). And it logs up to 500 points of temperature data to internal memory. You can use the 53 II to measure contact temperature on motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, E, N, R, or S-type thermocouple temperature sensors. The user-friendly-front panel and large, backlit display make it easy to view results and recall logged data for further review. And the sleep mode feature preserves battery life to give you a typical thousand hours of operation.

Sku: FLU-53-2-B
Vendor: Fluke
On Back-Order
$815.99 CAD

Key features

  • Single Input digital thermometer with data logging for lab, QA, process calibration, food safety and HVAC
  • Logs up to 500 points of data at user adjustable recording intervals
  • Measures J, K, T, E, R, S, and N-type thermocouples
  • Presents results in °C, °F, or Kelvin (K) on a large backlit display
  • Provides a recall function to easily review logged data
Specifications
Temperature accuracy Above -100°C J, K, T, E, and N-type: ±[0.05% + 0.3°C]1
R and S-type: ±[0.05% + 0.4°C]1
Below -100°C J, K, E, and N-types: ±[0.20% + 0.3°C]1
T-type: ±[0.50% + 0.3°C]
Temperature J-type: -210°C to 1200°C
K-type -200°C to 1372°C
T-type -250°C to 400°C
E-type -150°C to 1000°C
N-type -200°C to 1300°C 1
R and S-type 0°C to 1767°C 1
Temperature scale ITS-90
Applicable standards NIST-175
Display resolution 0.1°C, 0.1 K < 1000
1°C, 1 K ≥ 1000
1. Only the Fluke Models 53 II B and 54 II Bthermometers are capable of measuring N, R, and S-type thermocouples.
Environmental Specifications
Operating temperature -10°C to 50°C
Storage temperature -40°C to 60°C
Humidity (without condensation) 0% to 90%; 0°C to 35°C
0% to 70%; 0°C to 50°C
Safety Specifications
Overvoltage category CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2
Agency approvals CE, CSA, TÜV (pending)
Mechanical and General Specifications
Size (L x W x D) 173 x 86 x 38 mm
Weight 400 g
Batteries 3 AA batteries; typical 1000-hour life


Includes:

  • Impact absorbing holster
  • One 80PK-1 bead probe thermocouple

Related Products