Dry Blocks

{"id":7907873423550,"title":"Fluke 9009 Dual Dry Block Temperature Calibrator","handle":"fluke-9009-dual-dry-block-temperature-calibrator","description":"\u003cp\u003eThe Model 9009 includes two independently controlled temperature blocks. The hot block provides temperatures from 50 °C to 350 °C, while the cold block covers the range –15 °C to 110 °C. Each block is controlled by a precision Hart Scientific temperature controller. These aren’t some off-the-shelf controllers we glued into a box. These are Hart Scientific controllers from the leading temperature company in the world.\u003c\/p\u003e\n\u003cp\u003eEach temperature block includes two wells with removable inserts. You can calibrate four probes at once, or you can calibrate two probes at the same time with an external reference (like Hart’s Model 1521 LLK Thermometer), or you can use the two temperature wells to get quick “zero\" and “span\" references for transmitter calibrations.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDouble your productivity or cut your calibration time in half\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperatures from –15 °C to 350 °C in one unit\u003c\/li\u003e\n\u003cli\u003eTwo wells in each block for simultaneous comparison calibrations\u003c\/li\u003e\n\u003cli\u003eRugged, lightweight, water-resistant enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou’ve been asking for it and now we’re making it for you. Hart’s new Model 9009 Industrial Dual-Block Calibrator lets you calibrate at hot and cold temperatures at the same time. Double your productivity or cut your calibration time in half—either way you look at it, your in-field temperature calibrations just got easier.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"3\"\u003e\u003cb data-mce-fragment=\"1\"\u003eGeneral Specifications\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eHot block\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eCold block\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRange\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e50°C to 350°C (122°F to 662°F)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e–15°C to 110°C (5°F to 230°F)\u003cbr data-mce-fragment=\"1\"\u003e(–8°C [18°F] with hot block at 350°C [662°F])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e±0.6°C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e±0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStability\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e±0.05°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWell-to-well uniformity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e0.1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eHeating times\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e30 minutes from 25°C to 350°C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e15 minutes from 25°C to 110°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eCooling times\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e40 minutes from 350°C to 100°C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e16 minutes from 25°C to –15°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStabilization times\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e8 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWell depth\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e4 in (102 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRemovable inserts\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003eTwo 6.4 mm (1\/4 in) and two 4.8 mm (3\/16 in) inserts included; see ordering information for other available inserts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eComputer interface\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003eRS-232 included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePower\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e115 V AC (±10 %), 3 A, or\u003cbr data-mce-fragment=\"1\"\u003e230 V AC (±10 %), 2 A, specify, 50\/60 Hz, 280 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSize (H x W x D)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e178 x 267 x 248 mm (7 x 10.5 x 9.75 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e4.5 kg (10 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eNIST-traceable calibration\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eData at 50°C, 100°C, 150°C, 200°C, 250°C, 300°C, and 350°C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eData at –8°C, 0°C, 25°C, 50°C, 75°C, 100°C, and 110°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cli\u003eDry Well\u003c\/li\u003e\n\u003cli\u003eReport of Calibration with Calibration Label\u003c\/li\u003e\n\u003cli\u003e2 x 3102-3 ( 3\/16\") and two 3102-4 (¼\") Inserts\u003c\/li\u003e\n\u003cli\u003ePower Cord\u003c\/li\u003e\n\u003cli\u003eRS-232 Cable\u003c\/li\u003e\n\u003cli\u003eInsert Removal Tool\u003c\/li\u003e\n\u003cli\u003eUser's Manual\u003c\/li\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_9009_Dual-Well_Dry-Well_Spec_Sheet.pdf?v=1708616638\" target=\"_blank\" title=\"Fluke 9009 Datasheet\" rel=\"noopener noreferrer\"\u003eFluke 9009 Datasheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2024-02-22T08:38:18-07:00","created_at":"2024-02-22T08:38:18-07:00","vendor":"Fluke","type":"Dry Blocks","tags":[],"price":1153688,"price_min":1153688,"price_max":1153688,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":43576565072062,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-9009-B-156","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 9009 Dual Dry Block Temperature Calibrator","public_title":null,"options":["Default Title"],"price":1153688,"weight":5443,"compare_at_price":null,"inventory_management":"shopify","barcode":"0 95969 12842 1","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/files\/Fluke9009Pic1.jpg?v=1708616526","\/\/kingswayinstruments.com\/cdn\/shop\/files\/Fluke9009Pic2.jpg?v=1708616535"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/Fluke9009Pic1.jpg?v=1708616526","options":["Title"],"media":[{"alt":null,"id":27037241770174,"position":1,"preview_image":{"aspect_ratio":0.863,"height":313,"width":270,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/Fluke9009Pic1.jpg?v=1708616526"},"aspect_ratio":0.863,"height":313,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/Fluke9009Pic1.jpg?v=1708616526","width":270},{"alt":null,"id":27037243539646,"position":2,"preview_image":{"aspect_ratio":1.333,"height":750,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/Fluke9009Pic2.jpg?v=1708616535"},"aspect_ratio":1.333,"height":750,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/Fluke9009Pic2.jpg?v=1708616535","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe Model 9009 includes two independently controlled temperature blocks. The hot block provides temperatures from 50 °C to 350 °C, while the cold block covers the range –15 °C to 110 °C. Each block is controlled by a precision Hart Scientific temperature controller. These aren’t some off-the-shelf controllers we glued into a box. These are Hart Scientific controllers from the leading temperature company in the world.\u003c\/p\u003e\n\u003cp\u003eEach temperature block includes two wells with removable inserts. You can calibrate four probes at once, or you can calibrate two probes at the same time with an external reference (like Hart’s Model 1521 LLK Thermometer), or you can use the two temperature wells to get quick “zero\" and “span\" references for transmitter calibrations.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDouble your productivity or cut your calibration time in half\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTemperatures from –15 °C to 350 °C in one unit\u003c\/li\u003e\n\u003cli\u003eTwo wells in each block for simultaneous comparison calibrations\u003c\/li\u003e\n\u003cli\u003eRugged, lightweight, water-resistant enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou’ve been asking for it and now we’re making it for you. Hart’s new Model 9009 Industrial Dual-Block Calibrator lets you calibrate at hot and cold temperatures at the same time. Double your productivity or cut your calibration time in half—either way you look at it, your in-field temperature calibrations just got easier.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"3\"\u003e\u003cb data-mce-fragment=\"1\"\u003eGeneral Specifications\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e \u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eHot block\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eCold block\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRange\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e50°C to 350°C (122°F to 662°F)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e–15°C to 110°C (5°F to 230°F)\u003cbr data-mce-fragment=\"1\"\u003e(–8°C [18°F] with hot block at 350°C [662°F])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e±0.6°C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e±0.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStability\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e±0.05°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWell-to-well uniformity\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e0.1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eHeating times\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e30 minutes from 25°C to 350°C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e15 minutes from 25°C to 110°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eCooling times\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e40 minutes from 350°C to 100°C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e16 minutes from 25°C to –15°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eStabilization times\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e8 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWell depth\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e4 in (102 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRemovable inserts\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003eTwo 6.4 mm (1\/4 in) and two 4.8 mm (3\/16 in) inserts included; see ordering information for other available inserts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eComputer interface\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003eRS-232 included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003ePower\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e115 V AC (±10 %), 3 A, or\u003cbr data-mce-fragment=\"1\"\u003e230 V AC (±10 %), 2 A, specify, 50\/60 Hz, 280 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSize (H x W x D)\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e178 x 267 x 248 mm (7 x 10.5 x 9.75 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\" colspan=\"2\"\u003e4.5 kg (10 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eNIST-traceable calibration\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eData at 50°C, 100°C, 150°C, 200°C, 250°C, 300°C, and 350°C\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eData at –8°C, 0°C, 25°C, 50°C, 75°C, 100°C, and 110°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cli\u003eDry Well\u003c\/li\u003e\n\u003cli\u003eReport of Calibration with Calibration Label\u003c\/li\u003e\n\u003cli\u003e2 x 3102-3 ( 3\/16\") and two 3102-4 (¼\") Inserts\u003c\/li\u003e\n\u003cli\u003ePower Cord\u003c\/li\u003e\n\u003cli\u003eRS-232 Cable\u003c\/li\u003e\n\u003cli\u003eInsert Removal Tool\u003c\/li\u003e\n\u003cli\u003eUser's Manual\u003c\/li\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_9009_Dual-Well_Dry-Well_Spec_Sheet.pdf?v=1708616638\" target=\"_blank\" title=\"Fluke 9009 Datasheet\" rel=\"noopener noreferrer\"\u003eFluke 9009 Datasheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 9009 Dual Dry Block Temperature Calibrator

Fluke 9009 Dual Dry Block Temperature Calibrator

$11,536.88 CAD

The Model 9009 includes two independently controlled temperature blocks. The hot block provides temperatures from 50 °C to 350 °C, while the cold block covers the range –15 °C to 110 °C. Each block is controlled by a precision Hart Scientific temperature controller. These aren’t some off-the-shelf controllers we glued into a box. These are Hart ...


More Info
Additel 875 Dry Well Temperature Calibrator

Dry Blocks

From $10,483.20 CAD
{"id":4432380166217,"title":"Additel 875 Dry Well Temperature Calibrator","handle":"additel-875-dry-well-temperature-calibrator","description":"\u003cp\u003eIf you are serious about portable temperature calibration tools, then you know a good dry well calibrator is more than just a stable heat source. The Additel 875 Series Dry Well Calibrators combine excellent performance in stability, radial and axial uniformity, and loading with speed, ruggedness and portability. The Process Calibrator option adds the capabilities of a three-channel thermometer readout and a documenting process calibrator. Additel has also incorporated a unique option to select your own temperature range within the range of the model selected, calling this the CYOR option or \"Choose Your Own Range\" option. When you purchase the CYOR option, you pick the upper and lower temperature range needed and we calibrate and optimize the dry well’s performance over your selected range. Each unit has a color touch screen display, dual-zone control, and much more.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThree models ranging from -40°C to 660°C\u003c\/li\u003e\n\u003cli\u003ePortable,rugged, and quick to temperature\u003c\/li\u003e\n\u003cli\u003eMetrology-level performance in stability, uniformity, accuracy and loading effect\u003c\/li\u003e\n\u003cli\u003eDual-zone control\u003c\/li\u003e\n\u003cli\u003eProcess calibrator option provides a multi-channel readout for a reference thermometer, RTDs and TCs, task documentation, and HART Communication\u003c\/li\u003e\n\u003cli\u003eColor touch screen display\u003c\/li\u003e\n\u003cli\u003eChoose your own range option\u003c\/li\u003e\n\u003cli\u003eSet point control by reference\u003c\/li\u003e\n\u003cli\u003eSelf-calibration feature\u003c\/li\u003e\n\u003cli\u003eISO 17025-accredited calibration w\/data included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003eSee Resources for Product Datasheet and Selection Guide\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDry well and selected insert\u003c\/li\u003e\n\u003cli\u003ePower adapter\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003cli\u003eInsert removal tool\u003c\/li\u003e\n\u003cli\u003eThermal Shield (ADT875\/PC-350\/660 only)\u003c\/li\u003e\n\u003cli\u003eSilica gel plug (ADT875\/PC-155 only) 1 set (3 pcs.)\u003c\/li\u003e\n\u003cli\u003eInsulation plug (ADT875\/PC-155 only)\u003c\/li\u003e\n\u003cli\u003eTest leads (ADT875PC only) 2 sets (6 pcs.)\u003c\/li\u003e\n\u003cli\u003eCertificate of calibration\u003c\/li\u003e\n\u003cli\u003eCD Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Additel_875_Datasheet.pdf?v=1587504503\" target=\"_blank\" title=\"Additel 875 Spec Sheet\" rel=\"noopener noreferrer\"\u003eAdditel 875 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2020-04-21T15:21:48-06:00","created_at":"2020-04-21T15:21:48-06:00","vendor":"Additel","type":"Dry Blocks","tags":[],"price":1048320,"price_min":1048320,"price_max":1716680,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":31408434413641,"title":"-40°C to 155°C","option1":"-40°C to 155°C","option2":null,"option3":null,"sku":"ADT875-155-A-110V","requires_shipping":true,"taxable":true,"featured_image":{"id":13822455316553,"product_id":4432380166217,"position":2,"created_at":"2020-04-21T15:22:10-06:00","updated_at":"2020-04-21T15:22:10-06:00","alt":null,"width":1600,"height":1200,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic2.jpg?v=1587504130","variant_ids":[31408434413641,31408434446409,31408434479177]},"available":true,"name":"Additel 875 Dry Well Temperature Calibrator - -40°C to 155°C","public_title":"-40°C to 155°C","options":["-40°C to 155°C"],"price":1359400,"weight":9072,"compare_at_price":null,"inventory_management":"shopify","barcode":"","featured_media":{"alt":null,"id":5995506958409,"position":2,"preview_image":{"aspect_ratio":1.333,"height":1200,"width":1600,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic2.jpg?v=1587504130"}},"requires_selling_plan":false,"selling_plan_allocations":[]},{"id":31408434511945,"title":"-40°C to 155°C w\/PC","option1":"-40°C to 155°C w\/PC","option2":null,"option3":null,"sku":"ADT875PC-155-A-110V","requires_shipping":true,"taxable":true,"featured_image":{"id":13822455251017,"product_id":4432380166217,"position":1,"created_at":"2020-04-21T15:22:05-06:00","updated_at":"2020-04-21T15:22:05-06:00","alt":null,"width":1600,"height":1059,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic1.jpg?v=1587504125","variant_ids":[31408434511945,31408434544713,31408434577481]},"available":true,"name":"Additel 875 Dry Well Temperature Calibrator - -40°C to 155°C w\/PC","public_title":"-40°C to 155°C w\/PC","options":["-40°C to 155°C w\/PC"],"price":1716680,"weight":9072,"compare_at_price":null,"inventory_management":"shopify","barcode":"","featured_media":{"alt":null,"id":5995506925641,"position":1,"preview_image":{"aspect_ratio":1.511,"height":1059,"width":1600,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic1.jpg?v=1587504125"}},"requires_selling_plan":false,"selling_plan_allocations":[]},{"id":31408434446409,"title":"33°C to 350°C","option1":"33°C to 350°C","option2":null,"option3":null,"sku":"ADT875-350-A-110V","requires_shipping":true,"taxable":true,"featured_image":{"id":13822455316553,"product_id":4432380166217,"position":2,"created_at":"2020-04-21T15:22:10-06:00","updated_at":"2020-04-21T15:22:10-06:00","alt":null,"width":1600,"height":1200,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic2.jpg?v=1587504130","variant_ids":[31408434413641,31408434446409,31408434479177]},"available":true,"name":"Additel 875 Dry Well Temperature Calibrator - 33°C to 350°C","public_title":"33°C to 350°C","options":["33°C to 350°C"],"price":1048320,"weight":9072,"compare_at_price":null,"inventory_management":"shopify","barcode":"","featured_media":{"alt":null,"id":5995506958409,"position":2,"preview_image":{"aspect_ratio":1.333,"height":1200,"width":1600,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic2.jpg?v=1587504130"}},"requires_selling_plan":false,"selling_plan_allocations":[]},{"id":31408434544713,"title":"33°C to 350°C w\/PC","option1":"33°C to 350°C w\/PC","option2":null,"option3":null,"sku":"ADT875PC-350-A-110V","requires_shipping":true,"taxable":true,"featured_image":{"id":13822455251017,"product_id":4432380166217,"position":1,"created_at":"2020-04-21T15:22:05-06:00","updated_at":"2020-04-21T15:22:05-06:00","alt":null,"width":1600,"height":1059,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic1.jpg?v=1587504125","variant_ids":[31408434511945,31408434544713,31408434577481]},"available":true,"name":"Additel 875 Dry Well Temperature Calibrator - 33°C to 350°C w\/PC","public_title":"33°C to 350°C w\/PC","options":["33°C to 350°C w\/PC"],"price":1414840,"weight":9072,"compare_at_price":null,"inventory_management":"shopify","barcode":"","featured_media":{"alt":null,"id":5995506925641,"position":1,"preview_image":{"aspect_ratio":1.511,"height":1059,"width":1600,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic1.jpg?v=1587504125"}},"requires_selling_plan":false,"selling_plan_allocations":[]},{"id":31408434479177,"title":"33°C to 660°C","option1":"33°C to 660°C","option2":null,"option3":null,"sku":"ADT875-660-A-110V","requires_shipping":true,"taxable":true,"featured_image":{"id":13822455316553,"product_id":4432380166217,"position":2,"created_at":"2020-04-21T15:22:10-06:00","updated_at":"2020-04-21T15:22:10-06:00","alt":null,"width":1600,"height":1200,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic2.jpg?v=1587504130","variant_ids":[31408434413641,31408434446409,31408434479177]},"available":true,"name":"Additel 875 Dry Well Temperature Calibrator - 33°C to 660°C","public_title":"33°C to 660°C","options":["33°C to 660°C"],"price":1126020,"weight":9072,"compare_at_price":null,"inventory_management":"shopify","barcode":"","featured_media":{"alt":null,"id":5995506958409,"position":2,"preview_image":{"aspect_ratio":1.333,"height":1200,"width":1600,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic2.jpg?v=1587504130"}},"requires_selling_plan":false,"selling_plan_allocations":[]},{"id":31408434577481,"title":"33°C to 660°C w\/PC","option1":"33°C to 660°C w\/PC","option2":null,"option3":null,"sku":"ADT875PC-660-A-110V","requires_shipping":true,"taxable":true,"featured_image":{"id":13822455251017,"product_id":4432380166217,"position":1,"created_at":"2020-04-21T15:22:05-06:00","updated_at":"2020-04-21T15:22:05-06:00","alt":null,"width":1600,"height":1059,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic1.jpg?v=1587504125","variant_ids":[31408434511945,31408434544713,31408434577481]},"available":true,"name":"Additel 875 Dry Well Temperature Calibrator - 33°C to 660°C w\/PC","public_title":"33°C to 660°C w\/PC","options":["33°C to 660°C w\/PC"],"price":1490300,"weight":9072,"compare_at_price":null,"inventory_management":"shopify","barcode":"","featured_media":{"alt":null,"id":5995506925641,"position":1,"preview_image":{"aspect_ratio":1.511,"height":1059,"width":1600,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic1.jpg?v=1587504125"}},"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic1.jpg?v=1587504125","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic2.jpg?v=1587504130"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic1.jpg?v=1587504125","options":["Range"],"media":[{"alt":null,"id":5995506925641,"position":1,"preview_image":{"aspect_ratio":1.511,"height":1059,"width":1600,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic1.jpg?v=1587504125"},"aspect_ratio":1.511,"height":1059,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic1.jpg?v=1587504125","width":1600},{"alt":null,"id":5995506958409,"position":2,"preview_image":{"aspect_ratio":1.333,"height":1200,"width":1600,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic2.jpg?v=1587504130"},"aspect_ratio":1.333,"height":1200,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Additel875pic2.jpg?v=1587504130","width":1600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eIf you are serious about portable temperature calibration tools, then you know a good dry well calibrator is more than just a stable heat source. The Additel 875 Series Dry Well Calibrators combine excellent performance in stability, radial and axial uniformity, and loading with speed, ruggedness and portability. The Process Calibrator option adds the capabilities of a three-channel thermometer readout and a documenting process calibrator. Additel has also incorporated a unique option to select your own temperature range within the range of the model selected, calling this the CYOR option or \"Choose Your Own Range\" option. When you purchase the CYOR option, you pick the upper and lower temperature range needed and we calibrate and optimize the dry well’s performance over your selected range. Each unit has a color touch screen display, dual-zone control, and much more.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThree models ranging from -40°C to 660°C\u003c\/li\u003e\n\u003cli\u003ePortable,rugged, and quick to temperature\u003c\/li\u003e\n\u003cli\u003eMetrology-level performance in stability, uniformity, accuracy and loading effect\u003c\/li\u003e\n\u003cli\u003eDual-zone control\u003c\/li\u003e\n\u003cli\u003eProcess calibrator option provides a multi-channel readout for a reference thermometer, RTDs and TCs, task documentation, and HART Communication\u003c\/li\u003e\n\u003cli\u003eColor touch screen display\u003c\/li\u003e\n\u003cli\u003eChoose your own range option\u003c\/li\u003e\n\u003cli\u003eSet point control by reference\u003c\/li\u003e\n\u003cli\u003eSelf-calibration feature\u003c\/li\u003e\n\u003cli\u003eISO 17025-accredited calibration w\/data included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003eSee Resources for Product Datasheet and Selection Guide\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDry well and selected insert\u003c\/li\u003e\n\u003cli\u003ePower adapter\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003cli\u003eInsert removal tool\u003c\/li\u003e\n\u003cli\u003eThermal Shield (ADT875\/PC-350\/660 only)\u003c\/li\u003e\n\u003cli\u003eSilica gel plug (ADT875\/PC-155 only) 1 set (3 pcs.)\u003c\/li\u003e\n\u003cli\u003eInsulation plug (ADT875\/PC-155 only)\u003c\/li\u003e\n\u003cli\u003eTest leads (ADT875PC only) 2 sets (6 pcs.)\u003c\/li\u003e\n\u003cli\u003eCertificate of calibration\u003c\/li\u003e\n\u003cli\u003eCD Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Additel_875_Datasheet.pdf?v=1587504503\" target=\"_blank\" title=\"Additel 875 Spec Sheet\" rel=\"noopener noreferrer\"\u003eAdditel 875 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Additel 875 Dry Well Temperature Calibrator

Additel 875 Dry Well Temperature Calibrator

$14,903.00 CAD

If you are serious about portable temperature calibration tools, then you know a good dry well calibrator is more than just a stable heat source. The Additel 875 Series Dry Well Calibrators combine excellent performance in stability, radial and axial uniformity, and loading with speed, ruggedness and portability. The Process Calibrator option ad...


More Info
{"id":1838172504107,"title":"Fluke 9100S Dry Block Temperature Calibrator","handle":"fluke-9100s-dry-block-temperature-calibrator","description":"\u003cp\u003eSince we introduced the world’s first truly handheld dry-well, many have tried to duplicate it—in vain. Despite its small size (2¼ inches high and 5 inches wide) and light weight, the 9100S outperforms every dry-well in its class in the world.\u003c\/p\u003e\n\u003cp\u003eIt’s simple and convenient, too. Anyone can learn to use one in less than 15 minutes. It has a range to 375°C (707°F) and is perfect for checking RTDs, thermocouples, and small bimetal thermometers in the field.\u003c\/p\u003e\n\u003cp\u003ePlug it in, switch it on (Note, these wells are fixed and not interchangeable,) set the temperature with the front-panel buttons, and insert your probe into the properly sized well. Compare the reading of your device to the display temperature or to an external reference, and the difference is the error in your device. With a proprietary Fluke Calibration temperature controller, the 9100S has a display resolution of 0.1 degrees, an accuracy of ±0.5°C, a stability of ±0.1°C, and a stabilization time of just five minutes.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBlock \"A\" handles a full range of probe sizes with a single well of each size (1\/16\", 1\/8\", 1\/4\", 5\/32\"; 2 wells of 3\/16\")\u003c\/li\u003e\n\u003cli\u003eBlock \"B\" features four different size wells (1\/8\", 3\/16\", 1\/4\", 3\/8\")\u003c\/li\u003e\n\u003cli\u003eBlock \"C\" has two wells, one well is 3\/16\" in diameter, the other has a diameter of 1\/2\" and accepts 9102H inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSmallest dry-wells in the world\u003c\/li\u003e\n\u003cli\u003eRanges from –10°C to 375°C\u003c\/li\u003e\n\u003cli\u003eAccuracy to ±0.25°C, stability of ±0.05°C at 0°C\u003c\/li\u003e\n\u003cli\u003eRS-232 interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFluke Calibration's line of portable dry-wells is incredible. They’re the smallest, lightest, and most portable dry-wells in the world. And now they're better than ever!\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e35 to 375°C (95 to 707°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.25°C @ 50°C; ±0.25°C @ 100°C; ±0.5°C @ 375°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e±0.07°C @ 50°C; ±0.1°C @ 100°C; ±0.3°C @ 375°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell-to-Well Uniformity\u003c\/td\u003e\n\u003ctd\u003e±0.2°C with sensors of similar size at equal depths within wells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell Depth\u003c\/td\u003e\n\u003ctd\u003e4\" (102mm); 1\/16\" (1.6mm) hole is 3.5\" (89mm) deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStabilization Time\u003c\/td\u003e\n\u003ctd\u003e5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Time\u003c\/td\u003e\n\u003ctd\u003eAmbient to 375°C: 9.5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Time\u003c\/td\u003e\n\u003ctd\u003e375°C to 100°C: 14 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e9100S Dry Block Temperature Calibrator\u003c\/li\u003e\n\u003cli\u003eVariety block insert (see model options for insert sizes) *Inserts are fixed and not interchangeable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_9100S_-_9102S_Spec_Sheet.PDF?1592\" target=\"_blank\" title=\"Fluke 9100S Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 9100S Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-07-22T13:34:57-06:00","created_at":"2019-07-22T13:34:57-06:00","vendor":"Fluke","type":"Dry Blocks","tags":[],"price":420100,"price_min":420100,"price_max":420100,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16793265307691,"title":"9100S-A-156","option1":"9100S-A-156","option2":null,"option3":null,"sku":"FLU-9100S-A-156","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 9100S Dry Block Temperature Calibrator - 9100S-A-156","public_title":"9100S-A-156","options":["9100S-A-156"],"price":420100,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969017831","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16793366659115,"title":"9100S-B-156","option1":"9100S-B-156","option2":null,"option3":null,"sku":"FLU-9100S-B-156","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 9100S Dry Block Temperature Calibrator - 9100S-B-156","public_title":"9100S-B-156","options":["9100S-B-156"],"price":420100,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969205603","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16793366691883,"title":"9100S-C-156","option1":"9100S-C-156","option2":null,"option3":null,"sku":"FLU-9100S-C-156","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 9100S Dry Block Temperature Calibrator - 9100S-C-156","public_title":"9100S-C-156","options":["9100S-C-156"],"price":420100,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969017879","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9100S_Pic.jpg?v=1563824711","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9100S_Pic_2.jpg?v=1563824718"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9100S_Pic.jpg?v=1563824711","options":["Model"],"media":[{"alt":null,"id":2804026409003,"position":1,"preview_image":{"aspect_ratio":0.607,"height":1500,"width":911,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9100S_Pic.jpg?v=1563824711"},"aspect_ratio":0.607,"height":1500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9100S_Pic.jpg?v=1563824711","width":911},{"alt":null,"id":2804026802219,"position":2,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9100S_Pic_2.jpg?v=1563824718"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9100S_Pic_2.jpg?v=1563824718","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eSince we introduced the world’s first truly handheld dry-well, many have tried to duplicate it—in vain. Despite its small size (2¼ inches high and 5 inches wide) and light weight, the 9100S outperforms every dry-well in its class in the world.\u003c\/p\u003e\n\u003cp\u003eIt’s simple and convenient, too. Anyone can learn to use one in less than 15 minutes. It has a range to 375°C (707°F) and is perfect for checking RTDs, thermocouples, and small bimetal thermometers in the field.\u003c\/p\u003e\n\u003cp\u003ePlug it in, switch it on (Note, these wells are fixed and not interchangeable,) set the temperature with the front-panel buttons, and insert your probe into the properly sized well. Compare the reading of your device to the display temperature or to an external reference, and the difference is the error in your device. With a proprietary Fluke Calibration temperature controller, the 9100S has a display resolution of 0.1 degrees, an accuracy of ±0.5°C, a stability of ±0.1°C, and a stabilization time of just five minutes.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBlock \"A\" handles a full range of probe sizes with a single well of each size (1\/16\", 1\/8\", 1\/4\", 5\/32\"; 2 wells of 3\/16\")\u003c\/li\u003e\n\u003cli\u003eBlock \"B\" features four different size wells (1\/8\", 3\/16\", 1\/4\", 3\/8\")\u003c\/li\u003e\n\u003cli\u003eBlock \"C\" has two wells, one well is 3\/16\" in diameter, the other has a diameter of 1\/2\" and accepts 9102H inserts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSmallest dry-wells in the world\u003c\/li\u003e\n\u003cli\u003eRanges from –10°C to 375°C\u003c\/li\u003e\n\u003cli\u003eAccuracy to ±0.25°C, stability of ±0.05°C at 0°C\u003c\/li\u003e\n\u003cli\u003eRS-232 interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFluke Calibration's line of portable dry-wells is incredible. They’re the smallest, lightest, and most portable dry-wells in the world. And now they're better than ever!\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e35 to 375°C (95 to 707°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.25°C @ 50°C; ±0.25°C @ 100°C; ±0.5°C @ 375°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e±0.07°C @ 50°C; ±0.1°C @ 100°C; ±0.3°C @ 375°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell-to-Well Uniformity\u003c\/td\u003e\n\u003ctd\u003e±0.2°C with sensors of similar size at equal depths within wells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell Depth\u003c\/td\u003e\n\u003ctd\u003e4\" (102mm); 1\/16\" (1.6mm) hole is 3.5\" (89mm) deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStabilization Time\u003c\/td\u003e\n\u003ctd\u003e5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Time\u003c\/td\u003e\n\u003ctd\u003eAmbient to 375°C: 9.5 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Time\u003c\/td\u003e\n\u003ctd\u003e375°C to 100°C: 14 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e9100S Dry Block Temperature Calibrator\u003c\/li\u003e\n\u003cli\u003eVariety block insert (see model options for insert sizes) *Inserts are fixed and not interchangeable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_9100S_-_9102S_Spec_Sheet.PDF?1592\" target=\"_blank\" title=\"Fluke 9100S Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 9100S Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 9100S Dry Block Temperature Calibrator

Fluke 9100S Dry Block Temperature Calibrator

$4,201.00 CAD

Since we introduced the world’s first truly handheld dry-well, many have tried to duplicate it—in vain. Despite its small size (2¼ inches high and 5 inches wide) and light weight, the 9100S outperforms every dry-well in its class in the world. It’s simple and convenient, too. Anyone can learn to use one in less than 15 minutes. It has a range to...


More Info
{"id":1838102904875,"title":"Fluke 9144-A-156 Dry Block Temperature Calibrator","handle":"fluke-9144-a-156-dry-block-temperature-calibrator","description":"\u003cp\u003eThe 9142, 9143, 9144 Field Metrology Wells extend high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance.\u003c\/p\u003e\n\u003cp\u003eField Metrology Wells are packed with functionality and are remarkably easy to use. They are lightweight, small, and quick to reach temperature set points, yet they are stable, uniform, and accurate. These industrial temperature loop calibrators are perfect for performing transmitter loop calibrations, comparison calibrations, or simple checks of thermocouple sensors. With the “process” option, there is no need to carry additional tools into the field. This optional built-in two-channel readout reads resistance, voltage, and 4–20 mA current with 24 volt loop power. It also has on-board automation and documentation. Combined, the three models (9142, 9143, and 9144—each with a “process” option) cover the wide range of –25 °C to 660 °C.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHeats up to 660 °C in only 15 minutes!\u003c\/li\u003e\n\u003cli\u003eControl all functions from the front panel or hook it up to your PC with its built-in RS-232 port\u003c\/li\u003e\n\u003cli\u003eFour removable well inserts available\u003c\/li\u003e\n\u003cli\u003eHeating and cooling rate of each of these dry blocks is adjustable from the front panel\u003c\/li\u003e\n\u003cli\u003eVery easy to calibrate, you don't even have to open the case; meaning less maintenance costs and less down time when they do need recalibration\u003c\/li\u003e\n\u003cli\u003eInterface-it software lets you adjust set points and ramp rates, log dry block readings to a file, create an electronic strip chart, and perform thermal switch testing with data collection\u003c\/li\u003e\n\u003cli\u003eMultiple hole inserts are available for a variety of probe sizes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e50 to 660°C (122 to 1220°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.35°C at 50°C, ±.4°C at 420°C, ±.5°C at 660°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e±0.03°C at 50°C, ±0.04°C at 420°C, ±0.05°C at 660°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell-to-Well Uniformity\u003c\/td\u003e\n\u003ctd\u003e±0.05°C \u0026lt; 50°C, ±0.35°C \u0026gt; 420°C, ±0.5°C \u0026gt; 660°C w\/ similarly sized wells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmersion Depth \/ Well Diameter\u003c\/td\u003e\n\u003ctd\u003e5.9'' (150mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStabilization Time\u003c\/td\u003e\n\u003ctd\u003e7 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Time\u003c\/td\u003e\n\u003ctd\u003e15 minutes from ambient to 660°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Time\u003c\/td\u003e\n\u003ctd\u003e25 minutes from 650 to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cli\u003eFluke 9144-A-156 Dry Block Temperature Calibrator\u003c\/li\u003e\n\u003cli\u003eSerial Cable\u003c\/li\u003e\n\u003cli\u003eInsert Removal Tool\u003c\/li\u003e\n\u003cli\u003eManual \u003c\/li\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e","published_at":"2019-07-22T10:08:30-06:00","created_at":"2019-07-22T10:15:09-06:00","vendor":"Fluke","type":"Dry Blocks","tags":[],"price":973488,"price_min":973488,"price_max":973488,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16792348360747,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-9144-A-156","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 9144-A-156 Dry Block Temperature Calibrator","public_title":null,"options":["Default Title"],"price":973488,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969420242","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9144_Pic.jpg?v=1563812112","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9144_Pic_2.jpg?v=1563812113"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9144_Pic.jpg?v=1563812112","options":["Title"],"media":[{"alt":null,"id":2803893141547,"position":1,"preview_image":{"aspect_ratio":0.8,"height":675,"width":540,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9144_Pic.jpg?v=1563812112"},"aspect_ratio":0.8,"height":675,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9144_Pic.jpg?v=1563812112","width":540},{"alt":null,"id":2803893174315,"position":2,"preview_image":{"aspect_ratio":1.603,"height":312,"width":500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9144_Pic_2.jpg?v=1563812113"},"aspect_ratio":1.603,"height":312,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9144_Pic_2.jpg?v=1563812113","width":500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe 9142, 9143, 9144 Field Metrology Wells extend high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance.\u003c\/p\u003e\n\u003cp\u003eField Metrology Wells are packed with functionality and are remarkably easy to use. They are lightweight, small, and quick to reach temperature set points, yet they are stable, uniform, and accurate. These industrial temperature loop calibrators are perfect for performing transmitter loop calibrations, comparison calibrations, or simple checks of thermocouple sensors. With the “process” option, there is no need to carry additional tools into the field. This optional built-in two-channel readout reads resistance, voltage, and 4–20 mA current with 24 volt loop power. It also has on-board automation and documentation. Combined, the three models (9142, 9143, and 9144—each with a “process” option) cover the wide range of –25 °C to 660 °C.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHeats up to 660 °C in only 15 minutes!\u003c\/li\u003e\n\u003cli\u003eControl all functions from the front panel or hook it up to your PC with its built-in RS-232 port\u003c\/li\u003e\n\u003cli\u003eFour removable well inserts available\u003c\/li\u003e\n\u003cli\u003eHeating and cooling rate of each of these dry blocks is adjustable from the front panel\u003c\/li\u003e\n\u003cli\u003eVery easy to calibrate, you don't even have to open the case; meaning less maintenance costs and less down time when they do need recalibration\u003c\/li\u003e\n\u003cli\u003eInterface-it software lets you adjust set points and ramp rates, log dry block readings to a file, create an electronic strip chart, and perform thermal switch testing with data collection\u003c\/li\u003e\n\u003cli\u003eMultiple hole inserts are available for a variety of probe sizes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e50 to 660°C (122 to 1220°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.35°C at 50°C, ±.4°C at 420°C, ±.5°C at 660°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e±0.03°C at 50°C, ±0.04°C at 420°C, ±0.05°C at 660°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell-to-Well Uniformity\u003c\/td\u003e\n\u003ctd\u003e±0.05°C \u0026lt; 50°C, ±0.35°C \u0026gt; 420°C, ±0.5°C \u0026gt; 660°C w\/ similarly sized wells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmersion Depth \/ Well Diameter\u003c\/td\u003e\n\u003ctd\u003e5.9'' (150mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStabilization Time\u003c\/td\u003e\n\u003ctd\u003e7 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Time\u003c\/td\u003e\n\u003ctd\u003e15 minutes from ambient to 660°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Time\u003c\/td\u003e\n\u003ctd\u003e25 minutes from 650 to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cli\u003eFluke 9144-A-156 Dry Block Temperature Calibrator\u003c\/li\u003e\n\u003cli\u003eSerial Cable\u003c\/li\u003e\n\u003cli\u003eInsert Removal Tool\u003c\/li\u003e\n\u003cli\u003eManual \u003c\/li\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e"}
Fluke 9144-A-156 Dry Block Temperature Calibrator

Fluke 9144-A-156 Dry Block Temperature Calibrator

$9,734.88 CAD

The 9142, 9143, 9144 Field Metrology Wells extend high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance. Field Metrology Wells are packed with functionality and are remarkably easy to use. They are lightweight, small, and quick to reach temperatu...


More Info
{"id":1838095040555,"title":"Fluke 9140-A-156 Dry Block Temperature Calibrator","handle":"fluke-9140-a-156-dry-block-temperature-calibrator","description":"\u003cp\u003eThe 9140 has a temperature range of 35 °C to 350 °C, and it reaches its maximum temperature in 12 minutes. At six pounds, it’s small enough to easily carry in one hand. It’s truly a unique innovation in dry-wells.\u003c\/p\u003e\n\u003cp\u003eThe unit has a stability of ±0.05 °C or better and a uniformity of at least 0.4 °C in the largest-diameter wells and 0.1 °C in the smaller wells. Despite its small size, this unit performs.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature range of 35 to 350°C, and it reaches its maximum temperature in 12 minutes\u003c\/li\u003e\n\u003cli\u003eStability of ±0.05°C or better and a uniformity of at least 0.4°C in the largest-diameter wells and 0.1°C in the smaller wells\u003c\/li\u003e\n\u003cli\u003eHeating and cooling rates are adjustable from the front panel, thermal switches can be checked for actuation testing, and multiple-hole inserts are available for a variety of probe sizes\u003c\/li\u003e\n\u003cli\u003eUse the display, calibrated to ±0.5°C, as your reference, or use an external thermometer for maximum calibration accuracy\u003c\/li\u003e\n\u003cli\u003eEasy to calibrate, you don't even have to open the case\u003c\/li\u003e\n\u003cli\u003eInterface-it software lets you adjust set-points and ramp rates, log dry-well readings to a file, create an electronic strip chart, and perform thermal switch testing with data collection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e35 to 350°C (95 to 662°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C (±0.9°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e±0.03°C @ 50°C, ±0.05°C @ 350°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniformity\u003c\/td\u003e\n\u003ctd\u003e±0.1°C with similar size wells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C\/°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStabilization Time\u003c\/td\u003e\n\u003ctd\u003e7 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Time\u003c\/td\u003e\n\u003ctd\u003e12 minutes from ambient to 350°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Time\u003c\/td\u003e\n\u003ctd\u003e15 minutes from 350 to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmersion Depth\u003c\/td\u003e\n\u003ctd\u003e4.875\" (124mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e9140-A-156 Dry Block Temperature Calibrator\u003c\/li\u003e\n\u003cli\u003eVariety block insert with six different well sizes (1\/16\", 1\/8\", 3\/16\", 1\/4\", 3\/8\", 1\/2\")\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e","published_at":"2019-07-22T09:40:00-06:00","created_at":"2019-07-22T09:46:07-06:00","vendor":"Fluke","type":"Dry Blocks","tags":[],"price":577500,"price_min":577500,"price_max":577500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16792259788843,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-9140-A-156","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 9140-A-156 Dry Block Temperature Calibrator","public_title":null,"options":["Default Title"],"price":577500,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969128926","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9140_Dryblock_Pic.jpg?v=1563810370"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9140_Dryblock_Pic.jpg?v=1563810370","options":["Title"],"media":[{"alt":null,"id":2803882557483,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9140_Dryblock_Pic.jpg?v=1563810370"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_9140_Dryblock_Pic.jpg?v=1563810370","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe 9140 has a temperature range of 35 °C to 350 °C, and it reaches its maximum temperature in 12 minutes. At six pounds, it’s small enough to easily carry in one hand. It’s truly a unique innovation in dry-wells.\u003c\/p\u003e\n\u003cp\u003eThe unit has a stability of ±0.05 °C or better and a uniformity of at least 0.4 °C in the largest-diameter wells and 0.1 °C in the smaller wells. Despite its small size, this unit performs.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature range of 35 to 350°C, and it reaches its maximum temperature in 12 minutes\u003c\/li\u003e\n\u003cli\u003eStability of ±0.05°C or better and a uniformity of at least 0.4°C in the largest-diameter wells and 0.1°C in the smaller wells\u003c\/li\u003e\n\u003cli\u003eHeating and cooling rates are adjustable from the front panel, thermal switches can be checked for actuation testing, and multiple-hole inserts are available for a variety of probe sizes\u003c\/li\u003e\n\u003cli\u003eUse the display, calibrated to ±0.5°C, as your reference, or use an external thermometer for maximum calibration accuracy\u003c\/li\u003e\n\u003cli\u003eEasy to calibrate, you don't even have to open the case\u003c\/li\u003e\n\u003cli\u003eInterface-it software lets you adjust set-points and ramp rates, log dry-well readings to a file, create an electronic strip chart, and perform thermal switch testing with data collection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e35 to 350°C (95 to 662°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C (±0.9°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStability\u003c\/td\u003e\n\u003ctd\u003e±0.03°C @ 50°C, ±0.05°C @ 350°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUniformity\u003c\/td\u003e\n\u003ctd\u003e±0.1°C with similar size wells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C\/°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStabilization Time\u003c\/td\u003e\n\u003ctd\u003e7 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Time\u003c\/td\u003e\n\u003ctd\u003e12 minutes from ambient to 350°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Time\u003c\/td\u003e\n\u003ctd\u003e15 minutes from 350 to 100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmersion Depth\u003c\/td\u003e\n\u003ctd\u003e4.875\" (124mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e9140-A-156 Dry Block Temperature Calibrator\u003c\/li\u003e\n\u003cli\u003eVariety block insert with six different well sizes (1\/16\", 1\/8\", 3\/16\", 1\/4\", 3\/8\", 1\/2\")\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e"}
Fluke 9140-A-156 Dry Block Temperature Calibrator

Fluke 9140-A-156 Dry Block Temperature Calibrator

$5,775.00 CAD

The 9140 has a temperature range of 35 °C to 350 °C, and it reaches its maximum temperature in 12 minutes. At six pounds, it’s small enough to easily carry in one hand. It’s truly a unique innovation in dry-wells. The unit has a stability of ±0.05 °C or better and a uniformity of at least 0.4 °C in the largest-diameter wells and 0.1 °C in the sm...


More Info