{ "id":6700735168702, "title":"Industrial Scientific Ventis Multi-Gas Detector-LEL,CO,H2S,O2, Ext. Li-ion, Pump w\/ Conv. Kit (VTS-K1232120101)","handle":"industrial-scientific-ventis-multi-gas-detector-lel-co-h2s-o2-ext-li-ion-pump-w-conv-kit-vts-k1232120101", "description":"\u003cp\u003eIntroducing the Ventis MX4 – a compact, multi-gas monitor available in both aspirated and diffusion versions. The Ventis meets your gas detection needs with ease. It is the ideal instrument for monitoring one to four gases in confined spaces and nearly any other potentially hazardous environment. This lightweight instrument is available with a bright \"safety orange\" overmold providing visibility in darker environments. An extended range lithium-ion battery pack provides up to 20 hours of continuous monitoring when using the diffusion version. Compatible with iNet and our DSX™ Docking Station.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eGet the simple, reliable gas detection you need with the Ventis MX4, a four-gas monitor with the portability and size of a single-gas monitor. Designed to be extremely rugged yet lightweight and easy to wear, the Ventis MX4 eliminates the need for extra monitors and transitions seamlessly from personal monitoring to confined space entry thanks to the Ventis® Slide-on Pump. When your shift is over, maintenance, reporting, and data tracking are fast and easy with a DSXi Docking Station and iNet® Control software.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEliminate the need for two monitors by using Ventis MX4 for personal monitoring and confined space entry\u003c\/li\u003e\n\u003cli\u003eChoose your run time with 12-hour, 18-hour, or 20-hour batteries for non-pumped instruments\u003c\/li\u003e\n\u003cli\u003ePersonalize devices for your needs by selecting alarm thresholds, setting latch alarms, disabling the ability to power off while the instrument is in alarm, and more\u003c\/li\u003e\n\u003cli\u003eBacked by a 4-year warranty for monitor and standard four-gas sensors\u003c\/li\u003e\n\u003cli\u003eMonitor up to four of the following gases: LEL (Methane), LEL (Pentane), CO, H2S, O2, CO\/H2 Low, SO2, NO2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\" data-mce-selected=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth width=\"20%\"\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail Description\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cb\u003eTYPICAL RANGE OF GASES DETECTED\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCombustible Gases\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0-100% LEL in 1% increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMethane (CH4)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0-5% of vol. in 0.01% increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOxygen (O2)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0-30% of vol. in 0.1% increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCarbon Monoxide (CO)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0-1,000 ppm in 1 ppm increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eHydrogen Sulfide (H2S)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0-500 ppm in 0.1 ppm increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eNitrogen Dioxide (NO2)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0-150 ppm in 0.1 ppm increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSulfur Dioxide (SO2)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0-150 ppm in 0.1 ppm increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCase Material\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate with Protective Rubber Overmold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDimensions\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e103 mm x 58 mm x 30 mm (4.1” x 2.3” x 1.2”) - Ventis, Lithium-ion Battery Version (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e172 mm x 67 mm x 66 mm (6.8” x 2.6” x 2.6”) - Ventis with Pump, Lithium-ion Battery Version (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eWeight\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e182 g (6.4 oz) - Ventis, Lithium-ion Battery Version (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e380 g (13.4 oz) - Ventis with Pump, Lithium-ion Battery Version (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOperating Temperature Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C- 50°C (-4°F-122°F) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eOperating Humidity Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e15%-95% Non-condensing (continuous) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eDisplay\/Readout\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eBacklit Liquid Crystal Display (LCD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003ePower Source \/Run Time\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRechargeable Lithium-ion Battery Pack\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e(12 hours typical @ 20ºC) - Ventis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRechargeable Extended-Range Lithium-ion Battery Pack\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e(20 hours typical @ 20ºC) - Ventis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e(12 hours typical @ 20ºC) - Ventis with Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eReplaceable AAA Alkaline Battery Pack\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e(8 hours typical @ 20ºC) - Ventis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e(4 hours typical @ 20ºC) - Ventis with Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eAlarms\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eUltra-bright LEDs, loud audible alarm (95 dB at 30 cm) and vibrating alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eSensors\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cb\u003eCombustible gases\/methane - Catalytic Diffusion, O2, CO, H2S, NO2, SO2 - Electrochemical\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCERTIFICATIONS\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eUL\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 1, Groups A B C D, T4; Zone 0, AEx ia IIC T4 Class II, Groups F G (Carbonaceous \u0026amp; Grain Dust); P66; IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eATEX\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEx ia IIC T4 Ga and Ex ia I Ma; Equipment Group and Category II 1G and I M1; IP66; IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eIECEx\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEx ia IIC T4 Ga; IP66; IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eCSA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 1, Groups A B C D, T4; Ex d ia IIC T4 C22.2 No. 152 for %LEL reading only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eANZEx\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEx ia s Zone 0 I\/IIC T4; IP66; IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eINMETRO\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEx d ia IIC T4 Gb; IP66; IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eKOSHA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEx d ia IIC T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eMSHA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e30 CFR Part 22; Permissible for Underground Mines; diffusion (without pump) li-ion versions only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eChina EX\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEx ia d IIC T4 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eChina CMC\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eMetrology Approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eChina MA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eApproved for Underground Mines; diffusion (without pump) standard li-ion version only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCalibration Cup (without pump)\u003c\/li\u003e\n\u003cli\u003eSample Tubing (with pump)\u003c\/li\u003e\n\u003cli\u003eCharger\u003c\/li\u003e\n\u003cli\u003eReference Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Ventis_MX4_Gas_Monitor_Spec_Sheet.pdf?v=1620839665\" target=\"_blank\" title=\"Industrial Scientific Ventis Multi-Gas Detector Spec Sheet\" rel=\"noopener noreferrer\"\u003eIndustrial Scientific Ventis Multi-Gas Detector Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2021-05-12T12:29:25", "created_at":"2021-05-12T12:29:24", "vendor":"Industrial Scientific", "type":"Gas Monitors", "tags":[], "price":180994, "price_min":180994, "price_max":180994, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[39734667935934], "variants":[{ "id":39734667935934, "product_id":6700735168702, "product_handle":"industrial-scientific-ventis-multi-gas-detector-lel-co-h2s-o2-ext-li-ion-pump-w-conv-kit-vts-k1232120101", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"IND-VTS-K1232120101", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Industrial Scientific Ventis Multi-Gas Detector-LEL,CO,H2S,O2, Ext. Li-ion, Pump w\/ Conv. Kit (VTS-K1232120101) - Default Title", "options":["Default Title"], "price":180994, "weight":2268, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":""}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/VentisMX4PumpBlack.jpg?v=1620844386"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/VentisMX4PumpBlack.jpg?v=1620844386", "options":["Title"], "url":"\/products\/industrial-scientific-ventis-multi-gas-detector-lel-co-h2s-o2-ext-li-ion-pump-w-conv-kit-vts-k1232120101"}

Industrial Scientific Ventis Multi-Gas Detector-LEL,CO,H2S,O2, Ext. Li-ion, Pump w/ Conv. Kit (VTS-K1232120101)

Product Description

Introducing the Ventis MX4 – a compact, multi-gas monitor available in both aspirated and diffusion versions. The Ventis meets your gas detection needs with ease. It is the ideal instrument for monitoring one to four gases in confined spaces and nearly any other potentially hazardous environment. This lightweight instrument is available with a bright "safety orange" overmold providing visibility in darker environments. An extended range lithium-ion battery pack provides up to 20 hours of continuous monitoring when using the diffusion version. Compatible with iNet and our DSX™ Docking Station.

Sku: IND-VTS-K1232120101
On Back-Order
$1,809.94 CAD

Get the simple, reliable gas detection you need with the Ventis MX4, a four-gas monitor with the portability and size of a single-gas monitor. Designed to be extremely rugged yet lightweight and easy to wear, the Ventis MX4 eliminates the need for extra monitors and transitions seamlessly from personal monitoring to confined space entry thanks to the Ventis® Slide-on Pump. When your shift is over, maintenance, reporting, and data tracking are fast and easy with a DSXi Docking Station and iNet® Control software.

  • Eliminate the need for two monitors by using Ventis MX4 for personal monitoring and confined space entry
  • Choose your run time with 12-hour, 18-hour, or 20-hour batteries for non-pumped instruments
  • Personalize devices for your needs by selecting alarm thresholds, setting latch alarms, disabling the ability to power off while the instrument is in alarm, and more
  • Backed by a 4-year warranty for monitor and standard four-gas sensors
  • Monitor up to four of the following gases: LEL (Methane), LEL (Pentane), CO, H2S, O2, CO/H2 Low, SO2, NO2
Specification Detail Description
TYPICAL RANGE OF GASES DETECTED
Combustible Gases 0-100% LEL in 1% increments
Methane (CH4) 0-5% of vol. in 0.01% increments
Oxygen (O2) 0-30% of vol. in 0.1% increments
Carbon Monoxide (CO) 0-1,000 ppm in 1 ppm increments
Hydrogen Sulfide (H2S) 0-500 ppm in 0.1 ppm increments
Nitrogen Dioxide (NO2) 0-150 ppm in 0.1 ppm increments
Sulfur Dioxide (SO2) 0-150 ppm in 0.1 ppm increments
Case Material Polycarbonate with Protective Rubber Overmold
Dimensions 103 mm x 58 mm x 30 mm (4.1” x 2.3” x 1.2”) - Ventis, Lithium-ion Battery Version (typical)
172 mm x 67 mm x 66 mm (6.8” x 2.6” x 2.6”) - Ventis with Pump, Lithium-ion Battery Version (typical)
Weight 182 g (6.4 oz) - Ventis, Lithium-ion Battery Version (typical)
380 g (13.4 oz) - Ventis with Pump, Lithium-ion Battery Version (typical)
Operating Temperature Range -20°C- 50°C (-4°F-122°F) typical
Operating Humidity Range 15%-95% Non-condensing (continuous) typical
Display/Readout Backlit Liquid Crystal Display (LCD)
Power Source /Run Time
Rechargeable Lithium-ion Battery Pack (12 hours typical @ 20ºC) - Ventis
Rechargeable Extended-Range Lithium-ion Battery Pack (20 hours typical @ 20ºC) - Ventis
(12 hours typical @ 20ºC) - Ventis with Pump
Replaceable AAA Alkaline Battery Pack (8 hours typical @ 20ºC) - Ventis
(4 hours typical @ 20ºC) - Ventis with Pump
Alarms Ultra-bright LEDs, loud audible alarm (95 dB at 30 cm) and vibrating alarm
Sensors
Combustible gases/methane - Catalytic Diffusion, O2, CO, H2S, NO2, SO2 - Electrochemical
CERTIFICATIONS
UL Class I, Division 1, Groups A B C D, T4; Zone 0, AEx ia IIC T4 Class II, Groups F G (Carbonaceous & Grain Dust); P66; IP67
ATEX Ex ia IIC T4 Ga and Ex ia I Ma; Equipment Group and Category II 1G and I M1; IP66; IP67
IECEx Ex ia IIC T4 Ga; IP66; IP67
CSA Class I, Division 1, Groups A B C D, T4; Ex d ia IIC T4 C22.2 No. 152 for %LEL reading only
ANZEx Ex ia s Zone 0 I/IIC T4; IP66; IP67
INMETRO Ex d ia IIC T4 Gb; IP66; IP67
KOSHA Ex d ia IIC T4
MSHA 30 CFR Part 22; Permissible for Underground Mines; diffusion (without pump) li-ion versions only
China EX Ex ia d IIC T4 Gb
China CMC Metrology Approval
China MA Approved for Underground Mines; diffusion (without pump) standard li-ion version only


  • Calibration Cup (without pump)
  • Sample Tubing (with pump)
  • Charger
  • Reference Guide

Related Products