Health and Safety is our #1 Priority - As an essential service Kingsway Instruments is committed to ensuring ongoing services during the COVID19 crisis. Our Calibration Lab remains open and all equipment is cleaned and sanitized on return.

Laser Distance Meters

Fluke 424D Laser Distance Meter

Laser Distance Meters

$606.00 CAD
{"id":1076460224555,"title":"Fluke 424D Laser Distance Meter","handle":"fluke-424d-laser-distance-meter","description":"\u003cp\u003e\u003cstrong\u003eFluke 424D Laser Distance Meter delivers a full measure of sophisticated features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 424D is our most sophisticated laser distance meter packed with versatile features to save you more time in more situations and reduce errors. Just point and click to instantly measure up to 100 meters (330 ft.), accurate to + 1 mm. No scales to interpret or misread. The extra bright laser supports easy targeting even at longer distances. Extra features like a 180º inclination sensor, the corner angle feature, and a built-in compass make it easy to get accurate measurements in hard-to-reach locations. You'll be able to see the results more clearly on the large, four-line backlit display. No matter your job, the 424D laser distance meter will help you do the work of two people on your own.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eVersatile laser distance meter that instantly measures up to 100 meters (330 feet) with one-button point-and-click operation\u003c\/li\u003e\n\u003cli\u003eQuickly calculates area (square feet\/meters) and volume\u003c\/li\u003e\n\u003cli\u003eIncludes 180° inclination sensor for leveling and height tracking\u003c\/li\u003e\n\u003cli\u003eOffers enhanced Pythagoras calculation for determining distance indirectly from three other measurements \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eDistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical measuring tolerance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±1.0 mm\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum measuring tolerance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±2.0 mm\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange At Leica Target Plate GZM26\u003c\/td\u003e\n\u003ctd\u003e100 m \/ 330 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical range\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e80 m \/ 260 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange at unfavorable condition\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e60 m \/ 195 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmallest unit displayed\u003c\/td\u003e\n\u003ctd\u003e6 \/ 30 \/ 60 mm (10 \/ 50 \/ 100 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eØ Laser point at distances\u003c\/td\u003e\n\u003ctd\u003e6 \/ 30 \/ 60 mm (10 \/ 50 \/ 100 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eTilt Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring tolerance to laser beam\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±0.2°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring tolerance to housing\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±0.2°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e360°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser cass\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser type\u003c\/td\u003e\n\u003ctd\u003e635 nm, \u0026lt; 1 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic laser off\u003c\/td\u003e\n\u003ctd\u003eAfter 90 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic power off\u003c\/td\u003e\n\u003ctd\u003eAfter 180 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life (2 x AAA) 1.5 V NEDA 24A\/IEC LR03\u003c\/td\u003e\n\u003ctd\u003eUp to 5,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x D)\u003c\/td\u003e\n\u003ctd\u003e127 x 56 x 33 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with batteries)\u003c\/td\u003e\n\u003ctd\u003e158 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature range Storage operation\u003c\/td\u003e\n\u003ctd\u003e-25°C to +70°C (-13°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-10°C to +50°C (14°F to +122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration cycle\u003c\/td\u003e\n\u003ctd\u003eTilt and compass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum altitude\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum relative humidity\u003c\/td\u003e\n\u003ctd\u003e85% at 20°F to 120°F (-7°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC Standard No. 61010-1:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN60825-1:2007 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 55022:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN 61000-4-3:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN 61000-4-8:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo AAA batteries\u003c\/li\u003e\n\u003cli\u003eUsers manual on CD\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003cli\u003eVinyl carrying pouch\u003c\/li\u003e\n\u003cli\u003eLanyard\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_414D-419D-424D_Laser_Distance_Spec_6b36bf1f-e9ce-4523-a4cd-30bd4727f3dc.PDF?1829\" target=\"_blank\" title=\"Fluke 424D Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 424D Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-03-07T15:30:37-07:00","created_at":"2018-03-07T15:32:40-07:00","vendor":"Fluke","type":"Laser Distance Meters","tags":[],"price":60600,"price_min":60600,"price_max":60600,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11043987849259,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-424D","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 424D Laser Distance Meter","public_title":null,"options":["Default Title"],"price":60600,"weight":5000,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969613576","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/71DI5NCxUCL._SL1500.jpg?v=1520461962"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/71DI5NCxUCL._SL1500.jpg?v=1520461962","options":["Title"],"media":[{"alt":null,"id":1476072112171,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/71DI5NCxUCL._SL1500.jpg?v=1569271323"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/71DI5NCxUCL._SL1500.jpg?v=1569271323","width":1500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cstrong\u003eFluke 424D Laser Distance Meter delivers a full measure of sophisticated features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 424D is our most sophisticated laser distance meter packed with versatile features to save you more time in more situations and reduce errors. Just point and click to instantly measure up to 100 meters (330 ft.), accurate to + 1 mm. No scales to interpret or misread. The extra bright laser supports easy targeting even at longer distances. Extra features like a 180º inclination sensor, the corner angle feature, and a built-in compass make it easy to get accurate measurements in hard-to-reach locations. You'll be able to see the results more clearly on the large, four-line backlit display. No matter your job, the 424D laser distance meter will help you do the work of two people on your own.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eVersatile laser distance meter that instantly measures up to 100 meters (330 feet) with one-button point-and-click operation\u003c\/li\u003e\n\u003cli\u003eQuickly calculates area (square feet\/meters) and volume\u003c\/li\u003e\n\u003cli\u003eIncludes 180° inclination sensor for leveling and height tracking\u003c\/li\u003e\n\u003cli\u003eOffers enhanced Pythagoras calculation for determining distance indirectly from three other measurements \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eDistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical measuring tolerance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±1.0 mm\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum measuring tolerance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±2.0 mm\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange At Leica Target Plate GZM26\u003c\/td\u003e\n\u003ctd\u003e100 m \/ 330 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical range\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e80 m \/ 260 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange at unfavorable condition\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e60 m \/ 195 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmallest unit displayed\u003c\/td\u003e\n\u003ctd\u003e6 \/ 30 \/ 60 mm (10 \/ 50 \/ 100 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eØ Laser point at distances\u003c\/td\u003e\n\u003ctd\u003e6 \/ 30 \/ 60 mm (10 \/ 50 \/ 100 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eTilt Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring tolerance to laser beam\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±0.2°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring tolerance to housing\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±0.2°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e360°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser cass\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser type\u003c\/td\u003e\n\u003ctd\u003e635 nm, \u0026lt; 1 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic laser off\u003c\/td\u003e\n\u003ctd\u003eAfter 90 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic power off\u003c\/td\u003e\n\u003ctd\u003eAfter 180 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life (2 x AAA) 1.5 V NEDA 24A\/IEC LR03\u003c\/td\u003e\n\u003ctd\u003eUp to 5,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x D)\u003c\/td\u003e\n\u003ctd\u003e127 x 56 x 33 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with batteries)\u003c\/td\u003e\n\u003ctd\u003e158 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature range Storage operation\u003c\/td\u003e\n\u003ctd\u003e-25°C to +70°C (-13°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-10°C to +50°C (14°F to +122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration cycle\u003c\/td\u003e\n\u003ctd\u003eTilt and compass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum altitude\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum relative humidity\u003c\/td\u003e\n\u003ctd\u003e85% at 20°F to 120°F (-7°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC Standard No. 61010-1:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN60825-1:2007 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 55022:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN 61000-4-3:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN 61000-4-8:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo AAA batteries\u003c\/li\u003e\n\u003cli\u003eUsers manual on CD\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003cli\u003eVinyl carrying pouch\u003c\/li\u003e\n\u003cli\u003eLanyard\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_414D-419D-424D_Laser_Distance_Spec_6b36bf1f-e9ce-4523-a4cd-30bd4727f3dc.PDF?1829\" target=\"_blank\" title=\"Fluke 424D Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 424D Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 424D Laser Distance Meter

Fluke 424D Laser Distance Meter

$606.00 CAD

Fluke 424D Laser Distance Meter delivers a full measure of sophisticated features The Fluke 424D is our most sophisticated laser distance meter packed with versatile features to save you more time in more situations and reduce errors. Just point and click to instantly measure up to 100 meters (330 ft.), accurate to + 1 mm. No scales to interpret...


More Info
Fluke 419D Laser Distance Meter

Laser Distance Meters

$423.00 CAD
{"id":1076504264747,"title":"Fluke 419D Laser Distance Meter","handle":"fluke-419d-laser-distance-meter","description":"\u003cp\u003e\u003cstrong\u003eFluke 419D Laser Distance Meter extends your reach to 80 meters with high accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can use the Fluke 419D laser distance meter to measure up to 80 m (260 ft.), accurate to + 1 mm. No scales to interpret or misread. The extra bright laser makes it easy to target even at long distances. The 419D will help you save time and reduce errors with enhanced features like storage for 20 complete displays, indirect Pythagoras distance calculations, and the tripod mode for stable, long-distance measurements. And, you'll be able to see the results more easily on the backlit display. No matter your job, the 419D laser distance meter provides accurate long distance measurements to help you do the work of two people on your own.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVersatile laser distance meter that instantly measures up to 80 m (260 ft.) with one-button point-and-click operation\u003c\/li\u003e\n\u003cli\u003eQuickly calculates area (square feet\/meters) and volume\u003c\/li\u003e\n\u003cli\u003eOffers enhanced Pythagoras calculation for determining distance indirectly from three other measurements\u003c\/li\u003e\n\u003cli\u003eProvides easy to-use addition and subtraction function\u003c\/li\u003e\n\u003cli\u003eProvides audible keypad feedback \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eDistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical measuring tolerance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±1.0 mm\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum measuring tolerance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±2.0 mm\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange at Leica Target Plate GZM26\u003c\/td\u003e\n\u003ctd\u003e80 m \/ 260 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical range\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e80 m \/ 260 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange at unfavorable condition\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e60 m \/ 195 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmallest unit displayed\u003c\/td\u003e\n\u003ctd\u003e6 \/ 30 \/ 60 mm (10 \/ 50 \/ 100 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eØ Laser point at distances\u003c\/td\u003e\n\u003ctd\u003e6 \/ 30 \/ 60 mm\u003cbr\u003e(10 \/ 50 \/ 100 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eTilt measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring tolerance to laser beam\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring tolerance to housing\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser class\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser type\u003c\/td\u003e\n\u003ctd\u003e635 nm, \u0026lt; 1 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic laser off\u003c\/td\u003e\n\u003ctd\u003eAfter 90 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic power off\u003c\/td\u003e\n\u003ctd\u003eAfter 180 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life (2 x AAA) 1.5 V NEDA 24A\/IEC LR03\u003c\/td\u003e\n\u003ctd\u003eUp to 5,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x D)\u003c\/td\u003e\n\u003ctd\u003e127 x 56 x 33 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with batteries)\u003c\/td\u003e\n\u003ctd\u003e153 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature range Storage operation\u003c\/td\u003e\n\u003ctd\u003e-25°C to +70°C (-13°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-10°C to +50°C (14°F to +122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration cycle\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum altitude\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum relative humidity\u003c\/td\u003e\n\u003ctd\u003e85% at 20°F to 120°F (-7°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC Standard No. 61010-1:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN60825-1:2007 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 55022:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN 61000-4-3:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN 61000-4-8:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo AAA batteries\u003c\/li\u003e\n\u003cli\u003eUsers manual on CD\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003cli\u003eVinyl carrying pouch\u003c\/li\u003e\n\u003cli\u003eLanyard\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_414D-419D-424D_Laser_Distance_Spec.PDF?1829\" target=\"_blank\" title=\"Fluke 419D Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 419D Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-03-07T15:43:45-07:00","created_at":"2018-03-07T15:47:13-07:00","vendor":"Fluke","type":"Laser Distance Meters","tags":[],"price":42300,"price_min":42300,"price_max":42300,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11044154540075,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-419D","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 419D Laser Distance Meter","public_title":null,"options":["Default Title"],"price":42300,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969613569","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/6bcc715d870cef5a3f7ebf6217fd63b7.jpg?v=1520462835"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/6bcc715d870cef5a3f7ebf6217fd63b7.jpg?v=1520462835","options":["Title"],"media":[{"alt":null,"id":1476108189739,"position":1,"preview_image":{"aspect_ratio":1.0,"height":2400,"width":2400,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/6bcc715d870cef5a3f7ebf6217fd63b7.jpg?v=1569271329"},"aspect_ratio":1.0,"height":2400,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/6bcc715d870cef5a3f7ebf6217fd63b7.jpg?v=1569271329","width":2400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cstrong\u003eFluke 419D Laser Distance Meter extends your reach to 80 meters with high accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can use the Fluke 419D laser distance meter to measure up to 80 m (260 ft.), accurate to + 1 mm. No scales to interpret or misread. The extra bright laser makes it easy to target even at long distances. The 419D will help you save time and reduce errors with enhanced features like storage for 20 complete displays, indirect Pythagoras distance calculations, and the tripod mode for stable, long-distance measurements. And, you'll be able to see the results more easily on the backlit display. No matter your job, the 419D laser distance meter provides accurate long distance measurements to help you do the work of two people on your own.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVersatile laser distance meter that instantly measures up to 80 m (260 ft.) with one-button point-and-click operation\u003c\/li\u003e\n\u003cli\u003eQuickly calculates area (square feet\/meters) and volume\u003c\/li\u003e\n\u003cli\u003eOffers enhanced Pythagoras calculation for determining distance indirectly from three other measurements\u003c\/li\u003e\n\u003cli\u003eProvides easy to-use addition and subtraction function\u003c\/li\u003e\n\u003cli\u003eProvides audible keypad feedback \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eDistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical measuring tolerance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±1.0 mm\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum measuring tolerance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±2.0 mm\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange at Leica Target Plate GZM26\u003c\/td\u003e\n\u003ctd\u003e80 m \/ 260 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical range\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e80 m \/ 260 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange at unfavorable condition\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e60 m \/ 195 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmallest unit displayed\u003c\/td\u003e\n\u003ctd\u003e6 \/ 30 \/ 60 mm (10 \/ 50 \/ 100 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eØ Laser point at distances\u003c\/td\u003e\n\u003ctd\u003e6 \/ 30 \/ 60 mm\u003cbr\u003e(10 \/ 50 \/ 100 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eTilt measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring tolerance to laser beam\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring tolerance to housing\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser class\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser type\u003c\/td\u003e\n\u003ctd\u003e635 nm, \u0026lt; 1 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic laser off\u003c\/td\u003e\n\u003ctd\u003eAfter 90 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic power off\u003c\/td\u003e\n\u003ctd\u003eAfter 180 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life (2 x AAA) 1.5 V NEDA 24A\/IEC LR03\u003c\/td\u003e\n\u003ctd\u003eUp to 5,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x D)\u003c\/td\u003e\n\u003ctd\u003e127 x 56 x 33 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with batteries)\u003c\/td\u003e\n\u003ctd\u003e153 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature range Storage operation\u003c\/td\u003e\n\u003ctd\u003e-25°C to +70°C (-13°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-10°C to +50°C (14°F to +122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration cycle\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum altitude\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum relative humidity\u003c\/td\u003e\n\u003ctd\u003e85% at 20°F to 120°F (-7°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC Standard No. 61010-1:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN60825-1:2007 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 55022:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN 61000-4-3:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN 61000-4-8:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo AAA batteries\u003c\/li\u003e\n\u003cli\u003eUsers manual on CD\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003cli\u003eVinyl carrying pouch\u003c\/li\u003e\n\u003cli\u003eLanyard\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_414D-419D-424D_Laser_Distance_Spec.PDF?1829\" target=\"_blank\" title=\"Fluke 419D Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 419D Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 419D Laser Distance Meter

Fluke 419D Laser Distance Meter

$423.00 CAD

Fluke 419D Laser Distance Meter extends your reach to 80 meters with high accuracy You can use the Fluke 419D laser distance meter to measure up to 80 m (260 ft.), accurate to + 1 mm. No scales to interpret or misread. The extra bright laser makes it easy to target even at long distances. The 419D will help you save time and reduce errors with e...


More Info
Fluke 414D Distance Measuring Laser

Laser Distance Meters

$200.00 CAD
{"id":1076381188139,"title":"Fluke 414D Distance Measuring Laser","handle":"fluke-414d-laser-distance-meter","description":"\u003cp\u003e\u003cstrong\u003eFluke 414D Laser Distance Meter delivers professional-grade distance measurements quickly and easily\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 414D is a big step up from the common tape measure and it's much easier to use. Just point and click. No scales to interpret or misread. The 414D measures up to 50 meters (165 ft.), with 2 mm (0.08 in) accuracy and the extra bright laser makes targeting easy. This professional-grade laser distance meter is fast and easy to use to help improve accuracy and reduce measurement errors. You'll save time and money at every step.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRugged, professional grade laser distance meter featuring advanced laser distance measurement technology\u003c\/li\u003e\n\u003cli\u003eInstantly measures up to 50 m (165 ft.) with one-button point-and-click operation\u003c\/li\u003e\n\u003cli\u003eOffers Pythagoras calculation to indirectly measure height from two other measurements\u003c\/li\u003e\n\u003cli\u003eQuickly calculates area (square feet\/meters) and volume \u003c\/li\u003e\n\u003cli\u003eOffers easy to-use addition and subtraction function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eDistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical measuring tolerance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±2.0 mm\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum measuring tolerance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±3.0 mm\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange At Leica Target Plate GZM26\u003c\/td\u003e\n\u003ctd\u003e50 m \/ 165 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical range\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e40 m \/ 130 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange at unfavorable condition\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e35 m \/ 115 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmallest unit displayed\u003c\/td\u003e\n\u003ctd\u003e1 mm \/ 1\/16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eØ Laser point at distances\u003c\/td\u003e\n\u003ctd\u003e6 \/ 30 \/ 60 mm (10 \/ 50 \/ 100 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eTilt Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring tolerance to laser beam\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring tolerance to housing\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser class\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser type\u003c\/td\u003e\n\u003ctd\u003e635 nm, \u0026lt; 1 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic laser off\u003c\/td\u003e\n\u003ctd\u003eAfter 90 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic power off\u003c\/td\u003e\n\u003ctd\u003eAfter 180 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life (2 x AAA) 1.5 V NEDA 24A\/IEC LR03\u003c\/td\u003e\n\u003ctd\u003eUp to 3,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x D)\u003c\/td\u003e\n\u003ctd\u003e116 x 53 x 33 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with batteries)\u003c\/td\u003e\n\u003ctd\u003e113 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature range\u003cbr\u003eStorage operation\u003c\/td\u003e\n\u003ctd\u003e-25°C to +70°C (-13°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0°C to +40°C (32°F to +104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration cycle\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum altitude\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum relative humidity\u003c\/td\u003e\n\u003ctd\u003e85% at 20°F to 120°F (-7°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC Standard No. 61010-1:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN60825-1:2007 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 55022:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN 61000-4-3:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN 61000-4-8:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"2\"\u003e1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25°C.\u003cbr\u003e2. Applies for 10 to 500% target reflectivity, high background illumination, -10°C to +50°C.\u003cbr\u003e3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm\/m between 10 m to 30 m and to 0.15 mm\/m for distances above 30 m.\u003cbr\u003e4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux.\u003cbr\u003e5. After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo AAA batteries\u003c\/li\u003e\n\u003cli\u003eUsers manual on CD (17 languages)\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003cli\u003eVinyl carrying pouch\u003c\/li\u003e\n\u003cli\u003eLanyard\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_414D-419D-424D_Laser_Distance_Spec.PDF?1827\" target=\"_blank\" title=\"Fluke 414D Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 414D Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-03-07T15:00:53-07:00","created_at":"2018-03-07T15:03:14-07:00","vendor":"Fluke","type":"Laser Distance Meters","tags":[],"price":20000,"price_min":20000,"price_max":20000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11043637428267,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-414D","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 414D Distance Measuring Laser","public_title":null,"options":["Default Title"],"price":20000,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969613552","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/FLU_414D.jpg?v=1520460196"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/FLU_414D.jpg?v=1520460196","options":["Title"],"media":[{"alt":null,"id":1475991273515,"position":1,"preview_image":{"aspect_ratio":0.962,"height":1039,"width":1000,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/FLU_414D.jpg?v=1569271309"},"aspect_ratio":0.962,"height":1039,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/FLU_414D.jpg?v=1569271309","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cstrong\u003eFluke 414D Laser Distance Meter delivers professional-grade distance measurements quickly and easily\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 414D is a big step up from the common tape measure and it's much easier to use. Just point and click. No scales to interpret or misread. The 414D measures up to 50 meters (165 ft.), with 2 mm (0.08 in) accuracy and the extra bright laser makes targeting easy. This professional-grade laser distance meter is fast and easy to use to help improve accuracy and reduce measurement errors. You'll save time and money at every step.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRugged, professional grade laser distance meter featuring advanced laser distance measurement technology\u003c\/li\u003e\n\u003cli\u003eInstantly measures up to 50 m (165 ft.) with one-button point-and-click operation\u003c\/li\u003e\n\u003cli\u003eOffers Pythagoras calculation to indirectly measure height from two other measurements\u003c\/li\u003e\n\u003cli\u003eQuickly calculates area (square feet\/meters) and volume \u003c\/li\u003e\n\u003cli\u003eOffers easy to-use addition and subtraction function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eDistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical measuring tolerance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±2.0 mm\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum measuring tolerance\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±3.0 mm\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange At Leica Target Plate GZM26\u003c\/td\u003e\n\u003ctd\u003e50 m \/ 165 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical range\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e40 m \/ 130 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange at unfavorable condition\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e35 m \/ 115 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmallest unit displayed\u003c\/td\u003e\n\u003ctd\u003e1 mm \/ 1\/16 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eØ Laser point at distances\u003c\/td\u003e\n\u003ctd\u003e6 \/ 30 \/ 60 mm (10 \/ 50 \/ 100 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eTilt Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring tolerance to laser beam\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring tolerance to housing\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser class\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser type\u003c\/td\u003e\n\u003ctd\u003e635 nm, \u0026lt; 1 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection class\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic laser off\u003c\/td\u003e\n\u003ctd\u003eAfter 90 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic power off\u003c\/td\u003e\n\u003ctd\u003eAfter 180 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life (2 x AAA) 1.5 V NEDA 24A\/IEC LR03\u003c\/td\u003e\n\u003ctd\u003eUp to 3,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x D)\u003c\/td\u003e\n\u003ctd\u003e116 x 53 x 33 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (with batteries)\u003c\/td\u003e\n\u003ctd\u003e113 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature range\u003cbr\u003eStorage operation\u003c\/td\u003e\n\u003ctd\u003e-25°C to +70°C (-13°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0°C to +40°C (32°F to +104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration cycle\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum altitude\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum relative humidity\u003c\/td\u003e\n\u003ctd\u003e85% at 20°F to 120°F (-7°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC Standard No. 61010-1:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN60825-1:2007 (Class II)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 55022:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN 61000-4-3:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEN 61000-4-8:2010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"2\"\u003e1. Applies for 100% target reflectivity (white painted wall), low background illumination, 25°C.\u003cbr\u003e2. Applies for 10 to 500% target reflectivity, high background illumination, -10°C to +50°C.\u003cbr\u003e3. Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. The maximum tolerance may deteriorate to 0.1 mm\/m between 10 m to 30 m and to 0.15 mm\/m for distances above 30 m.\u003cbr\u003e4. Applies for 100% target reflectivity, background illumination between 10'000 lux and 30'000 lux.\u003cbr\u003e5. After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTwo AAA batteries\u003c\/li\u003e\n\u003cli\u003eUsers manual on CD (17 languages)\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003cli\u003eVinyl carrying pouch\u003c\/li\u003e\n\u003cli\u003eLanyard\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_414D-419D-424D_Laser_Distance_Spec.PDF?1827\" target=\"_blank\" title=\"Fluke 414D Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 414D Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 414D Distance Measuring Laser

Fluke 414D Distance Measuring Laser

$200.00 CAD

Fluke 414D Laser Distance Meter delivers professional-grade distance measurements quickly and easily The Fluke 414D is a big step up from the common tape measure and it's much easier to use. Just point and click. No scales to interpret or misread. The 414D measures up to 50 meters (165 ft.), with 2 mm (0.08 in) accuracy and the extra bright lase...


More Info