Oscilloscopes

{"id":1253590499371,"title":"Fluke 124B Industrial Hand-Held ScopeMeter Oscilloscope, 2 Channel, 40 MHZ","handle":"fluke-124-industrial-scopemeter","description":"\u003cp\u003e\u003cspan\u003eThe compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input digital oscilloscope and multimeter\u003c\/li\u003e\n\u003cli\u003eIncreased resolution and work load coverage with 40 MHz oscilloscope bandwidth\u003c\/li\u003e\n\u003cli\u003eTwo 5,000-count true-rms digital multimeters\u003c\/li\u003e\n\u003cli\u003eConnect-and-View™ trigger simplicity for hands-off operation; IntellaSet™ technology automatically and intelligently adjusts numerical readout\u003c\/li\u003e\n\u003cli\u003eDual-input waveform and meter reading recorder for trending data over extended periods\u003c\/li\u003e\n\u003cli\u003eRecorder Event Detect captures elusive intermittent signals\u003c\/li\u003e\n\u003cli\u003eWiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app*\u003c\/li\u003e\n\u003cli\u003eFlukeView® ScopeMeter® Software for Windows® (FLU-124\/B\/NA\/S)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eOscilloscope mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency response - dc coupled\u003c\/td\u003e\n\u003ctd\u003eWithout probes and test leads (with BB120)\u003c\/td\u003e\n\u003ctd\u003e123B: dc to 20 MHz (-3 dB)\u003cbr\u003e124B and 125B: dc to 40 MHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith STL120-IV 1:1 shielded test leads\u003c\/td\u003e\n\u003ctd\u003eDC to 12.5 MHz (-3 dB) \/ dc to 20 MHz (-6 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith VP41 10:1 Probe\u003c\/td\u003e\n\u003ctd\u003e123B: dc to 20MHz (-3 dB)\u003cbr\u003e124B and 125B: dc to 40 MHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency response - ac coupled (lf roll off)\u003c\/td\u003e\n\u003ctd\u003eWithout probes and test leads\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith STL120-IV 1:1 shielded test leads\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith VP41 10:1 Probe\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise time, excluding probes, \u003cbr\u003etest leads\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e123B \u0026lt;17.5 ns\u003cbr\u003e124B and 125B \u0026lt;8.75 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003eWithout probes and test leads\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\/\/20 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith BB120\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\/\/24 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith STL120-IV 1:1 shielded test leads\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\/\/230 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith VP41 10:1 Probe\u003c\/td\u003e\n\u003ctd\u003e5 MΩ\/\/15.5 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 mV to 200 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog bandwidth limiter\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay modes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA, -A, B, -B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMax. input voltage A and B\u003c\/td\u003e\n\u003ctd\u003eDirect, with test leads, or with VP41 Probe\u003c\/td\u003e\n\u003ctd\u003e600 Vrms Cat IV, 750 Vrms maximum voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith BB120\u003c\/td\u003e\n\u003ctd\u003e600 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. floating voltage, from any terminal to ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 Vrms Cat IV, 750 Vrms up to 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScope modes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormal, Single, Roll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eRanges (normal)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eEquivalent sampling\u003c\/td\u003e\n\u003ctd\u003e123B: 20 ns to 500 ns\/div,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 10 ns to 500 ns\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eReal time sampling\u003c\/td\u003e\n\u003ctd\u003e1 μs to 5 s\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eSingle (real time)\u003c\/td\u003e\n\u003ctd\u003e1 μs to 5 s\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eRoll (real time)\u003c\/td\u003e\n\u003ctd\u003e1s to 60 s\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSampling rate (for both channels simultaneously)\u003c\/td\u003e\n\u003ctd\u003eEquivalent sampling (repetitive signals)\u003c\/td\u003e\n\u003ctd\u003eUp to 4 GS\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eReal time sampling 1 μs to 60 s\/div\u003c\/td\u003e\n\u003ctd\u003e40 MS\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eTrigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen update\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFree run, on trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA, B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eSensitivity A and B\u003c\/td\u003e\n\u003ctd\u003e@ DC to 5 MHz\u003c\/td\u003e\n\u003ctd\u003e0.5 divisions or 5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" rowspan=\"2\"\u003e@ 40 MHz\u003c\/td\u003e\n\u003ctd\u003e123B: 4 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 1.5 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" rowspan=\"2\"\u003e@ 60 MHz\u003c\/td\u003e\n\u003ctd\u003e123B: N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 4 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePositive, negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAdvanced scope functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eDisplay modes\u003c\/td\u003e\n\u003ctd\u003eNormal\u003c\/td\u003e\n\u003ctd\u003eCaptures up to 25 ns glitches and displays analog-like persistence waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eSmooth\u003c\/td\u003e\n\u003ctd\u003eSuppresses noise from a waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eGlitch off\u003c\/td\u003e\n\u003ctd\u003eDoes not capture glitches between samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEnvelope\u003c\/td\u003e\n\u003ctd\u003eRecords and displays the minimum and maximum of waveforms over time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto set (Connect-and-View™)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eContinuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eDual input meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eAdd 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe  uncertainty +1%. More than one waveform period must be visible on the screen.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eInput A and input B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC voltage (VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.5% +5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection (CMRR)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;100 dB @ dc, \u0026gt;60 dB @ 50, 60, or 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eTrue-rms voltages (V ac and V ac+dc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy for 5% to 100% of range (DC coupled)\u003c\/td\u003e\n\u003ctd\u003eDC to 60 Hz (V ac+dc)\u003c\/td\u003e\n\u003ctd\u003e±(1% +10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e1 Hz to 60 Hz (V ac)\u003c\/td\u003e\n\u003ctd\u003e±(1% +10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy for 5% to 100% of range (AC or dc coupled)\u003c\/td\u003e\n\u003ctd\u003e60 Hz to 20 kHz\u003c\/td\u003e\n\u003ctd\u003e±(2.5% +15 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC rejection (only VAC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;50 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCommon mode rejection (CMRR)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;100 dB @ dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e\u0026gt;60 dB @ 50, 60, or 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts, reading is independent of any signal crest factor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePeak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMax peak, Min peak, or pk-to-pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 2200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eAccuracy Max peak or Min peak\u003c\/td\u003e\n\u003ctd\u003e5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy Peak-to-Peak\u003c\/td\u003e\n\u003ctd\u003e10% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFrequency (Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 Hz (1 Hz) to 50 MHz in continuous autoset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @1 Hz to 1 MHz\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.5% +2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10,000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eRPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50.00 kRPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.5% +2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDuty cycle (PULSE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2% to 98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 Hz (1 Hz) to 30 MHz in continuous autoset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePulse width (PULSE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 Hz (1 Hz) to 30 MHz in continuous autoset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAmperes (AMP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eWith current clamp\u003c\/td\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd\u003eSame as V dc, V ac, V ac+dc, or PEAK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eScale factors\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\/A, 1 mV\/A, 10 mV\/A, 100 mV\/A, 400 mV\/A, 1 V\/A, 10 mV\/mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eSame as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eTemperature (TEMP) with optional temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e200 °C\/div (200 °F\/div)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale factor\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mV\/°C and 1 mV\/°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAs V dc (add temp. probe uncertainty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDecibel (dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 dBV\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 dBm (600 Ω \/50 Ω)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mW referenced to 600 Ω or 50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edB on\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eV dc, V ac, or Vac+dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eCrest factor (CREST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 to 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e90 Counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePhase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA to B, B to A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 359 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 degree\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePower (125B only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurations\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 phase \/ 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower factor (PF)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRatio between watts and VA range - 0.00 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eWatt\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRMS reading of multiplying corresponding samples of input A (volts) and input B (amperes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eFull scale reading\u003c\/td\u003e\n\u003ctd\u003e999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVA\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eVrms x Arms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eFull scale reading\u003c\/td\u003e\n\u003ctd\u003e999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVA reactive (var)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e√((VA)\u003csup\u003e2\u003c\/sup\u003e-W\u003csup\u003e2\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eFull scale reading\u003c\/td\u003e\n\u003ctd\u003e999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eVpwm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePurpose\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTo measure on pulse width modulated signals, like motor drive inverter outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinciple\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eReadings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAs Vrms for sinewave signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eInput A to common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eOhm (Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eRanges\u003c\/td\u003e\n\u003ctd\u003e123B and 124B\u003c\/td\u003e\n\u003ctd\u003e500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e125B\u003c\/td\u003e\n\u003ctd\u003e50 Ω, 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 Ω to 5 MΩ - 5000 counts, 30 MΩ - 3000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5 mA to 50 nA, decreases with increasing ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eContinuity (Cont)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeep\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;(30 Ω ±5 Ω) in 50 Ω range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection of shorts of\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≥1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMeasurement voltage\u003c\/td\u003e\n\u003ctd\u003e@0.5 mA\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;2.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e@open circuit\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+ on input A, - on COM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eCapacitance (CAP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 nF, 500 nF, 5 μF, 50 μF, 500 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 nA to 0.5 mA, increases with increasing ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAdvanced meter functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Set\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSet actual value to reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoHold (on A)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCaptures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixed decimal point\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eActivated by using attenuation keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eCursor Readout (124B and 125B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSources\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA, B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eSingle vertical line\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAverage, min and max readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAverage, min, max and time from start of readout (in ROLL mode; instrument in HOLD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eMin, max and time from start of readout (in RECORDER mode; instrument in HOLD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eHarmonics values in POWER QUALITY mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDual vertical lines\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePeak-peak, time distance and reciprocal time distance readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAverage, min, max and time distance readout (in ROLL mode; instrument in HOLD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDual horizontal lines\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eHigh, low and peak-peak readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise or fall time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTransition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only \u003cbr\u003epossible in single channel mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAs oscilloscope accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eRecorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMeter readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Speed\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMaximum 2 measurement\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size (min, max, average)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 M readings for 1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eWaveform record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum sample rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 K sample\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize Internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 M samples Recorded Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 minutes at 500 μs\/div\u003cbr\u003e11 hours at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5 G samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e11 hours at 500 μs\/div\u003cbr\u003e14 days at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003ePower Quality (125B only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWatt, VA, var, PF, DPF, Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eWatt, VA, var ranges (auto)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e250 W to 250 MW, 625 MW, 1.56 GW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: total (% r)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 6 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: fundamental (% f)\u003c\/td\u003e\n\u003ctd\u003e±(4% + 4 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDPF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00, ±0.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10.0 Hz to 15.0 kHz\u003cbr\u003e40.0 Hz to 70.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Harmonics\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDC to 51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings \/ Cursor readings \u003cbr\u003e(fundamental 40 Hz to 70 Hz)\u003c\/td\u003e\n\u003ctd\u003eVrms \/ Arms \/Watt\u003c\/td\u003e\n\u003ctd\u003eEach harmonic from fundamental maybe selected for individual readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eIncludes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eBusHealth tester (Fluke 125B only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSubtype\u003c\/td\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAS-i\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNEN-EN50295\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAN\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eISO-11898\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterbus S\u003c\/td\u003e\n\u003ctd\u003eRS-422\u003c\/td\u003e\n\u003ctd\u003eEIA-422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eModbus\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003ctd\u003eRS-232\/EIA-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eRS-485\u003c\/td\u003e\n\u003ctd\u003eRS-485\/EIA-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoundation Fieldbus\u003c\/td\u003e\n\u003ctd\u003eH1\u003c\/td\u003e\n\u003ctd\u003e61158 type 1, 31.25 kBit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eProfibus\u003c\/td\u003e\n\u003ctd\u003eDP\u003c\/td\u003e\n\u003ctd\u003eEIA-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003ePA\u003c\/td\u003e\n\u003ctd\u003e61158 type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eMiscellaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e5.7-inch color active matrix TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eWaveform Display\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003ctd\u003e10 div of 40 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eHorizontal\u003c\/td\u003e\n\u003ctd\u003e12 div of 40 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"9\"\u003ePower\u003c\/td\u003e\n\u003ctd\u003eExternal\u003c\/td\u003e\n\u003ctd\u003eVia Power Adapter BC430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eInput voltage\u003c\/td\u003e\n\u003ctd\u003e10 V DC to 21 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003e5 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eInput connector\u003c\/td\u003e\n\u003ctd\u003e5 mm jack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eInternal\u003c\/td\u003e\n\u003ctd\u003eVia Battery Pack BP290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eBattery power\u003c\/td\u003e\n\u003ctd\u003eRechargeable Li-Ion 10.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e7 hours with 50% backlight brightness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4 hours with test tool off,  7 hours with test tool on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAllowable ambient temp\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (32 to 104 °F) during charging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eInternal memory can store 20 data sets  (screen waveform and setup)\u003c\/td\u003e\n\u003ctd\u003eMicro SD card slot with optional SD card  (max size of 32 GB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e259 x 132 x 55 mm \u003cbr\u003e(10.2 x 5.2 x 2.15 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.4 kg (3.2 lb) including battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eOptically isolated\u003c\/td\u003e\n\u003ctd\u003eTransfer screen copies (bitmaps), settings and data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eUSB to PC\/laptop\u003c\/td\u003e\n\u003ctd\u003eOC4USB optically isolated USB adapter\/cable, (optional), using FlukeView® software for Windows®.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eOptional WiFi adapter\u003c\/td\u003e\n\u003ctd\u003eFast transfer of screen copies (bitmaps), settings and data to PC\/laptop, tablet, smartphone, etc. A USB port is provided for attaching the WiFi dongle. Do not use the USB port with a cable for safety reasons.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMIL-PRF-28800F, Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eBattery Operation\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003ePower Adapter Operation\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 °C (-4 to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eHumidity (Operating)\u003c\/td\u003e\n\u003ctd\u003e@ 0 to 10 °C (32 to 50 °F)\u003c\/td\u003e\n\u003ctd\u003eNon-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e@ 10 to 30 °C (50 to 86 °F)\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e@ 30 to 40 °C (86 to 104 °F)\u003c\/td\u003e\n\u003ctd\u003e75%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e@ 40 to 50 °C (104 to 122 °F)\u003c\/td\u003e\n\u003ctd\u003e45%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e@ -20 to 60 °C (-4 to 140 °F)\u003c\/td\u003e\n\u003ctd\u003eNon-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating at 3 km (10,000 feet)\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eOperating at 2 km (6,600 feet)\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e12 km (40,000 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eEMC electromagnetic compatibility\u003c\/td\u003e\n\u003ctd\u003eInternational\u003c\/td\u003e\n\u003ctd\u003eIEC 61326-1: Industrial, CISPR 11:  Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eWireless radio with adapter\u003c\/td\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e2412 MHz to 2462 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;100 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP51, ref: EN\/IEC60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1: Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-2-033: CAT IV 600 V\/CAT III 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eMax. input voltage input A and B\u003c\/td\u003e\n\u003ctd\u003eDirect on input or with leads\u003c\/td\u003e\n\u003ctd\u003e600 Vrms CAT IV for derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith Banana-to-BNC Adapter BB120\u003c\/td\u003e\n\u003ctd\u003e600 Vrms for derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eMax. floating voltage from any terminal to ground\u003c\/td\u003e\n\u003ctd\u003e600 Vrms Cat IV, 750 Vrms up to 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOscilloscope\u003c\/li\u003e\n\u003cli\u003eAccessory List\u003c\/li\u003e\n\u003cli\u003eCD\u003c\/li\u003e\n\u003cli\u003eSafety Manual\u003c\/li\u003e\n\u003cli\u003eBanana to BNC Adapter\u003c\/li\u003e\n\u003cli\u003ePower Adapter\u003c\/li\u003e\n\u003cli\u003eShield Test Leads W\/ Black Ground Leads\u003c\/li\u003e\n\u003cli\u003eTL175 Test Leads\u003c\/li\u003e\n\u003cli\u003eBattery\u003c\/li\u003e\n\u003cli\u003eWiFi Dongle\u003c\/li\u003e\n\u003cli\u003eLine Cord\u003c\/li\u003e\n\u003cli\u003e10:1 Voltage Probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_ScopeMeter_Brochure_-_120_Series_190_Series.PDF?1800\" target=\"_blank\" title=\"Fluke 124B Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 124B Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-05-11T16:58:21-06:00","created_at":"2018-05-11T17:01:08-06:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":277400,"price_min":277400,"price_max":332900,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12050132172843,"title":"FLU-124B\/NA","option1":"FLU-124B\/NA","option2":null,"option3":null,"sku":"FLU-124B\/NA","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 124B Industrial Hand-Held ScopeMeter Oscilloscope, 2 Channel, 40 MHZ - FLU-124B\/NA","public_title":"FLU-124B\/NA","options":["FLU-124B\/NA"],"price":277400,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969814812"},{"id":30251325653035,"title":"FLU-124B\/NA\/S","option1":"FLU-124B\/NA\/S","option2":null,"option3":null,"sku":"FLU-124B\/NA\/S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 124B Industrial Hand-Held ScopeMeter Oscilloscope, 2 Channel, 40 MHZ - FLU-124B\/NA\/S","public_title":"FLU-124B\/NA\/S","options":["FLU-124B\/NA\/S"],"price":332900,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969815055"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-124-846.jpg?v=1526079670"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-124-846.jpg?v=1526079670","options":["Model"],"media":[{"alt":null,"id":1647110881323,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-124-846.jpg?v=1569303104"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-124-846.jpg?v=1569303104","width":1000}],"content":"\u003cp\u003e\u003cspan\u003eThe compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input digital oscilloscope and multimeter\u003c\/li\u003e\n\u003cli\u003eIncreased resolution and work load coverage with 40 MHz oscilloscope bandwidth\u003c\/li\u003e\n\u003cli\u003eTwo 5,000-count true-rms digital multimeters\u003c\/li\u003e\n\u003cli\u003eConnect-and-View™ trigger simplicity for hands-off operation; IntellaSet™ technology automatically and intelligently adjusts numerical readout\u003c\/li\u003e\n\u003cli\u003eDual-input waveform and meter reading recorder for trending data over extended periods\u003c\/li\u003e\n\u003cli\u003eRecorder Event Detect captures elusive intermittent signals\u003c\/li\u003e\n\u003cli\u003eWiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app*\u003c\/li\u003e\n\u003cli\u003eFlukeView® ScopeMeter® Software for Windows® (FLU-124\/B\/NA\/S)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eOscilloscope mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency response - dc coupled\u003c\/td\u003e\n\u003ctd\u003eWithout probes and test leads (with BB120)\u003c\/td\u003e\n\u003ctd\u003e123B: dc to 20 MHz (-3 dB)\u003cbr\u003e124B and 125B: dc to 40 MHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith STL120-IV 1:1 shielded test leads\u003c\/td\u003e\n\u003ctd\u003eDC to 12.5 MHz (-3 dB) \/ dc to 20 MHz (-6 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith VP41 10:1 Probe\u003c\/td\u003e\n\u003ctd\u003e123B: dc to 20MHz (-3 dB)\u003cbr\u003e124B and 125B: dc to 40 MHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency response - ac coupled (lf roll off)\u003c\/td\u003e\n\u003ctd\u003eWithout probes and test leads\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith STL120-IV 1:1 shielded test leads\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith VP41 10:1 Probe\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise time, excluding probes, \u003cbr\u003etest leads\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e123B \u0026lt;17.5 ns\u003cbr\u003e124B and 125B \u0026lt;8.75 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003eWithout probes and test leads\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\/\/20 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith BB120\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\/\/24 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith STL120-IV 1:1 shielded test leads\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\/\/230 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith VP41 10:1 Probe\u003c\/td\u003e\n\u003ctd\u003e5 MΩ\/\/15.5 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 mV to 200 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog bandwidth limiter\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay modes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA, -A, B, -B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMax. input voltage A and B\u003c\/td\u003e\n\u003ctd\u003eDirect, with test leads, or with VP41 Probe\u003c\/td\u003e\n\u003ctd\u003e600 Vrms Cat IV, 750 Vrms maximum voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith BB120\u003c\/td\u003e\n\u003ctd\u003e600 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. floating voltage, from any terminal to ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 Vrms Cat IV, 750 Vrms up to 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScope modes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormal, Single, Roll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eRanges (normal)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eEquivalent sampling\u003c\/td\u003e\n\u003ctd\u003e123B: 20 ns to 500 ns\/div,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 10 ns to 500 ns\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eReal time sampling\u003c\/td\u003e\n\u003ctd\u003e1 μs to 5 s\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eSingle (real time)\u003c\/td\u003e\n\u003ctd\u003e1 μs to 5 s\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eRoll (real time)\u003c\/td\u003e\n\u003ctd\u003e1s to 60 s\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSampling rate (for both channels simultaneously)\u003c\/td\u003e\n\u003ctd\u003eEquivalent sampling (repetitive signals)\u003c\/td\u003e\n\u003ctd\u003eUp to 4 GS\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eReal time sampling 1 μs to 60 s\/div\u003c\/td\u003e\n\u003ctd\u003e40 MS\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eTrigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen update\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFree run, on trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA, B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eSensitivity A and B\u003c\/td\u003e\n\u003ctd\u003e@ DC to 5 MHz\u003c\/td\u003e\n\u003ctd\u003e0.5 divisions or 5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" rowspan=\"2\"\u003e@ 40 MHz\u003c\/td\u003e\n\u003ctd\u003e123B: 4 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 1.5 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" rowspan=\"2\"\u003e@ 60 MHz\u003c\/td\u003e\n\u003ctd\u003e123B: N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 4 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePositive, negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAdvanced scope functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eDisplay modes\u003c\/td\u003e\n\u003ctd\u003eNormal\u003c\/td\u003e\n\u003ctd\u003eCaptures up to 25 ns glitches and displays analog-like persistence waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eSmooth\u003c\/td\u003e\n\u003ctd\u003eSuppresses noise from a waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eGlitch off\u003c\/td\u003e\n\u003ctd\u003eDoes not capture glitches between samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEnvelope\u003c\/td\u003e\n\u003ctd\u003eRecords and displays the minimum and maximum of waveforms over time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto set (Connect-and-View™)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eContinuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eDual input meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eAdd 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe  uncertainty +1%. More than one waveform period must be visible on the screen.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eInput A and input B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC voltage (VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.5% +5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection (CMRR)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;100 dB @ dc, \u0026gt;60 dB @ 50, 60, or 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eTrue-rms voltages (V ac and V ac+dc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy for 5% to 100% of range (DC coupled)\u003c\/td\u003e\n\u003ctd\u003eDC to 60 Hz (V ac+dc)\u003c\/td\u003e\n\u003ctd\u003e±(1% +10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e1 Hz to 60 Hz (V ac)\u003c\/td\u003e\n\u003ctd\u003e±(1% +10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy for 5% to 100% of range (AC or dc coupled)\u003c\/td\u003e\n\u003ctd\u003e60 Hz to 20 kHz\u003c\/td\u003e\n\u003ctd\u003e±(2.5% +15 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC rejection (only VAC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;50 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCommon mode rejection (CMRR)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;100 dB @ dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e\u0026gt;60 dB @ 50, 60, or 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts, reading is independent of any signal crest factor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePeak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMax peak, Min peak, or pk-to-pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 2200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eAccuracy Max peak or Min peak\u003c\/td\u003e\n\u003ctd\u003e5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy Peak-to-Peak\u003c\/td\u003e\n\u003ctd\u003e10% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFrequency (Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 Hz (1 Hz) to 50 MHz in continuous autoset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @1 Hz to 1 MHz\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.5% +2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10,000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eRPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50.00 kRPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.5% +2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDuty cycle (PULSE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2% to 98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 Hz (1 Hz) to 30 MHz in continuous autoset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePulse width (PULSE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 Hz (1 Hz) to 30 MHz in continuous autoset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAmperes (AMP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eWith current clamp\u003c\/td\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd\u003eSame as V dc, V ac, V ac+dc, or PEAK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eScale factors\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\/A, 1 mV\/A, 10 mV\/A, 100 mV\/A, 400 mV\/A, 1 V\/A, 10 mV\/mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eSame as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eTemperature (TEMP) with optional temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e200 °C\/div (200 °F\/div)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale factor\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mV\/°C and 1 mV\/°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAs V dc (add temp. probe uncertainty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDecibel (dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 dBV\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 dBm (600 Ω \/50 Ω)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mW referenced to 600 Ω or 50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edB on\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eV dc, V ac, or Vac+dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eCrest factor (CREST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 to 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e90 Counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePhase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA to B, B to A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 359 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 degree\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePower (125B only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurations\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 phase \/ 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower factor (PF)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRatio between watts and VA range - 0.00 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eWatt\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRMS reading of multiplying corresponding samples of input A (volts) and input B (amperes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eFull scale reading\u003c\/td\u003e\n\u003ctd\u003e999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVA\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eVrms x Arms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eFull scale reading\u003c\/td\u003e\n\u003ctd\u003e999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVA reactive (var)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e√((VA)\u003csup\u003e2\u003c\/sup\u003e-W\u003csup\u003e2\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eFull scale reading\u003c\/td\u003e\n\u003ctd\u003e999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eVpwm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePurpose\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTo measure on pulse width modulated signals, like motor drive inverter outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinciple\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eReadings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAs Vrms for sinewave signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eInput A to common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eOhm (Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eRanges\u003c\/td\u003e\n\u003ctd\u003e123B and 124B\u003c\/td\u003e\n\u003ctd\u003e500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e125B\u003c\/td\u003e\n\u003ctd\u003e50 Ω, 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 Ω to 5 MΩ - 5000 counts, 30 MΩ - 3000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5 mA to 50 nA, decreases with increasing ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eContinuity (Cont)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeep\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;(30 Ω ±5 Ω) in 50 Ω range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection of shorts of\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≥1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMeasurement voltage\u003c\/td\u003e\n\u003ctd\u003e@0.5 mA\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;2.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e@open circuit\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+ on input A, - on COM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eCapacitance (CAP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 nF, 500 nF, 5 μF, 50 μF, 500 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 nA to 0.5 mA, increases with increasing ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAdvanced meter functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Set\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSet actual value to reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoHold (on A)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCaptures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixed decimal point\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eActivated by using attenuation keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eCursor Readout (124B and 125B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSources\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA, B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eSingle vertical line\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAverage, min and max readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAverage, min, max and time from start of readout (in ROLL mode; instrument in HOLD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eMin, max and time from start of readout (in RECORDER mode; instrument in HOLD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eHarmonics values in POWER QUALITY mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDual vertical lines\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePeak-peak, time distance and reciprocal time distance readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAverage, min, max and time distance readout (in ROLL mode; instrument in HOLD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDual horizontal lines\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eHigh, low and peak-peak readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise or fall time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTransition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only \u003cbr\u003epossible in single channel mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAs oscilloscope accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eRecorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMeter readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Speed\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMaximum 2 measurement\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size (min, max, average)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 M readings for 1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eWaveform record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum sample rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 K sample\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize Internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 M samples Recorded Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 minutes at 500 μs\/div\u003cbr\u003e11 hours at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5 G samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e11 hours at 500 μs\/div\u003cbr\u003e14 days at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003ePower Quality (125B only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWatt, VA, var, PF, DPF, Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eWatt, VA, var ranges (auto)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e250 W to 250 MW, 625 MW, 1.56 GW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: total (% r)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 6 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: fundamental (% f)\u003c\/td\u003e\n\u003ctd\u003e±(4% + 4 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDPF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00, ±0.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10.0 Hz to 15.0 kHz\u003cbr\u003e40.0 Hz to 70.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Harmonics\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDC to 51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings \/ Cursor readings \u003cbr\u003e(fundamental 40 Hz to 70 Hz)\u003c\/td\u003e\n\u003ctd\u003eVrms \/ Arms \/Watt\u003c\/td\u003e\n\u003ctd\u003eEach harmonic from fundamental maybe selected for individual readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eIncludes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eBusHealth tester (Fluke 125B only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSubtype\u003c\/td\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAS-i\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNEN-EN50295\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAN\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eISO-11898\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterbus S\u003c\/td\u003e\n\u003ctd\u003eRS-422\u003c\/td\u003e\n\u003ctd\u003eEIA-422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eModbus\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003ctd\u003eRS-232\/EIA-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eRS-485\u003c\/td\u003e\n\u003ctd\u003eRS-485\/EIA-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoundation Fieldbus\u003c\/td\u003e\n\u003ctd\u003eH1\u003c\/td\u003e\n\u003ctd\u003e61158 type 1, 31.25 kBit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eProfibus\u003c\/td\u003e\n\u003ctd\u003eDP\u003c\/td\u003e\n\u003ctd\u003eEIA-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003ePA\u003c\/td\u003e\n\u003ctd\u003e61158 type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eMiscellaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e5.7-inch color active matrix TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eWaveform Display\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003ctd\u003e10 div of 40 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eHorizontal\u003c\/td\u003e\n\u003ctd\u003e12 div of 40 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"9\"\u003ePower\u003c\/td\u003e\n\u003ctd\u003eExternal\u003c\/td\u003e\n\u003ctd\u003eVia Power Adapter BC430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eInput voltage\u003c\/td\u003e\n\u003ctd\u003e10 V DC to 21 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003e5 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eInput connector\u003c\/td\u003e\n\u003ctd\u003e5 mm jack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eInternal\u003c\/td\u003e\n\u003ctd\u003eVia Battery Pack BP290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eBattery power\u003c\/td\u003e\n\u003ctd\u003eRechargeable Li-Ion 10.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e7 hours with 50% backlight brightness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4 hours with test tool off,  7 hours with test tool on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAllowable ambient temp\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (32 to 104 °F) during charging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eInternal memory can store 20 data sets  (screen waveform and setup)\u003c\/td\u003e\n\u003ctd\u003eMicro SD card slot with optional SD card  (max size of 32 GB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e259 x 132 x 55 mm \u003cbr\u003e(10.2 x 5.2 x 2.15 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.4 kg (3.2 lb) including battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eOptically isolated\u003c\/td\u003e\n\u003ctd\u003eTransfer screen copies (bitmaps), settings and data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eUSB to PC\/laptop\u003c\/td\u003e\n\u003ctd\u003eOC4USB optically isolated USB adapter\/cable, (optional), using FlukeView® software for Windows®.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eOptional WiFi adapter\u003c\/td\u003e\n\u003ctd\u003eFast transfer of screen copies (bitmaps), settings and data to PC\/laptop, tablet, smartphone, etc. A USB port is provided for attaching the WiFi dongle. Do not use the USB port with a cable for safety reasons.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMIL-PRF-28800F, Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eBattery Operation\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003ePower Adapter Operation\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 °C (-4 to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eHumidity (Operating)\u003c\/td\u003e\n\u003ctd\u003e@ 0 to 10 °C (32 to 50 °F)\u003c\/td\u003e\n\u003ctd\u003eNon-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e@ 10 to 30 °C (50 to 86 °F)\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e@ 30 to 40 °C (86 to 104 °F)\u003c\/td\u003e\n\u003ctd\u003e75%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e@ 40 to 50 °C (104 to 122 °F)\u003c\/td\u003e\n\u003ctd\u003e45%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e@ -20 to 60 °C (-4 to 140 °F)\u003c\/td\u003e\n\u003ctd\u003eNon-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating at 3 km (10,000 feet)\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eOperating at 2 km (6,600 feet)\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e12 km (40,000 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eEMC electromagnetic compatibility\u003c\/td\u003e\n\u003ctd\u003eInternational\u003c\/td\u003e\n\u003ctd\u003eIEC 61326-1: Industrial, CISPR 11:  Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eWireless radio with adapter\u003c\/td\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e2412 MHz to 2462 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;100 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP51, ref: EN\/IEC60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1: Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-2-033: CAT IV 600 V\/CAT III 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eMax. input voltage input A and B\u003c\/td\u003e\n\u003ctd\u003eDirect on input or with leads\u003c\/td\u003e\n\u003ctd\u003e600 Vrms CAT IV for derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith Banana-to-BNC Adapter BB120\u003c\/td\u003e\n\u003ctd\u003e600 Vrms for derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eMax. floating voltage from any terminal to ground\u003c\/td\u003e\n\u003ctd\u003e600 Vrms Cat IV, 750 Vrms up to 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOscilloscope\u003c\/li\u003e\n\u003cli\u003eAccessory List\u003c\/li\u003e\n\u003cli\u003eCD\u003c\/li\u003e\n\u003cli\u003eSafety Manual\u003c\/li\u003e\n\u003cli\u003eBanana to BNC Adapter\u003c\/li\u003e\n\u003cli\u003ePower Adapter\u003c\/li\u003e\n\u003cli\u003eShield Test Leads W\/ Black Ground Leads\u003c\/li\u003e\n\u003cli\u003eTL175 Test Leads\u003c\/li\u003e\n\u003cli\u003eBattery\u003c\/li\u003e\n\u003cli\u003eWiFi Dongle\u003c\/li\u003e\n\u003cli\u003eLine Cord\u003c\/li\u003e\n\u003cli\u003e10:1 Voltage Probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_ScopeMeter_Brochure_-_120_Series_190_Series.PDF?1800\" target=\"_blank\" title=\"Fluke 124B Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 124B Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 124B Industrial Hand-Held ScopeMeter Oscilloscope, 2 Channel, 40 MHZ

Fluke 124B Industrial Hand-Held ScopeMeter Oscilloscope, 2 Channel, 40 MHZ

$3,329.00 CAD

The compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with F...


More Info
Fluke 190-502/AM/S ScopeMeter® with Software

Oscilloscopes

$8,045.00 CAD
{"id":1076003733547,"title":"Fluke 190-502\/AM\/S ScopeMeter® with Software","handle":"fluke-190-502-scopemeter®-with-software","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eA faster sample rate and higher bandwidth means greater accuracy and clarity. The scope will capture and display unknown waveform shapes, amplitudes and any disturbances. In order to display at least the fifth harmonic component of a signal, a good rule of thumb is to select a scope with a bandwidth of at least five times the maximum clock rate of the device under test. The faster the sample interval, the more accurate and detailed the scope will display a signal edge (dV\/dt) and peaks of any reflections or transients.\u003c\/span\u003e","published_at":"2018-03-07T12:24:37-07:00","created_at":"2018-03-07T12:28:07-07:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":804500,"price_min":804500,"price_max":804500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11041195950123,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-190-502\/AM\/S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190-502\/AM\/S ScopeMeter® with Software","public_title":null,"options":["Default Title"],"price":804500,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969601795"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-502-am-s-d0c-1.jpg?v=1520450889"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-502-am-s-d0c-1.jpg?v=1520450889","options":["Title"],"media":[{"alt":null,"id":1475706650667,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-502-am-s-d0c-1.jpg?v=1569271261"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-502-am-s-d0c-1.jpg?v=1569271261","width":1000}],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eA faster sample rate and higher bandwidth means greater accuracy and clarity. The scope will capture and display unknown waveform shapes, amplitudes and any disturbances. In order to display at least the fifth harmonic component of a signal, a good rule of thumb is to select a scope with a bandwidth of at least five times the maximum clock rate of the device under test. The faster the sample interval, the more accurate and detailed the scope will display a signal edge (dV\/dt) and peaks of any reflections or transients.\u003c\/span\u003e"}
Fluke 190-502/AM/S ScopeMeter® with Software

Fluke 190-502/AM/S ScopeMeter® with Software

$8,045.00 CAD

A faster sample rate and higher bandwidth means greater accuracy and clarity. The scope will capture and display unknown waveform shapes, amplitudes and any disturbances. In order to display at least the fifth harmonic component of a signal, a good rule of thumb is to select a scope with a bandwidth of at least five times the maximum clock rate ...


More Info
Fluke 190-502/AM ScopeMeter®

Oscilloscopes

$7,397.00 CAD
{"id":1075909132331,"title":"Fluke 190-502\/AM ScopeMeter®","handle":"fluke-190-502-scopemeter®","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e5 GS\/s sampling rate, 500 MHz bandwidth with 2 input channels and DMM for electronic field service applications.\u003c\/span\u003e","published_at":"2018-03-07T12:00:31-07:00","created_at":"2018-03-07T12:02:43-07:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":739700,"price_min":739700,"price_max":739700,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11040570245163,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-190-502\/AM","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190-502\/AM ScopeMeter®","public_title":null,"options":["Default Title"],"price":739700,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969601726"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-502-am-s-d0c.jpg?v=1520449365"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-502-am-s-d0c.jpg?v=1520449365","options":["Title"],"media":[{"alt":null,"id":1475620470827,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-502-am-s-d0c.jpg?v=1569271248"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-502-am-s-d0c.jpg?v=1569271248","width":1000}],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e5 GS\/s sampling rate, 500 MHz bandwidth with 2 input channels and DMM for electronic field service applications.\u003c\/span\u003e"}
Fluke 190-502/AM ScopeMeter®

Fluke 190-502/AM ScopeMeter®

$7,397.00 CAD

5 GS/s sampling rate, 500 MHz bandwidth with 2 input channels and DMM for electronic field service applications.


More Info
Fluke 190-204/AM/S ScopeMeter® with Software

Oscilloscopes

$7,213.00 CAD
{"id":1069126189099,"title":"Fluke 190-204\/AM\/S ScopeMeter® with Software","handle":"fluke-190-204-s-scopemeter®-with-software","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eAs the first four-channel portable scope safety rated CAT III 1000V \/ CAT IV 600V, the Fluke ScopeMeter 190-204\/S combines an unprecedented level of performance, ruggedness, and portability with 200 MHz bandwidth and real-time sampling rates up to 2.5 GS\/s and 200 ps resolution to capture noise and other disturbances. This model features deep memory up to 10,000 samples per channel; so you can examine very small parts of the waveform in detail, and it is IP-51 rated to withstand dust, drips, humidity, and wide temperature variations.\u003c\/span\u003e","published_at":"2018-03-05T15:48:49-07:00","created_at":"2018-03-05T15:51:52-07:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":721300,"price_min":721300,"price_max":721300,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11001267912747,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-190-204\/AM\/S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190-204\/AM\/S ScopeMeter® with Software","public_title":null,"options":["Default Title"],"price":721300,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969580007"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-204-am-s-8cc.jpg?v=1520290314","\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/71aSJm7BTZL._SL1500_-1.jpg?v=1520290315"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-204-am-s-8cc.jpg?v=1520290314","options":["Title"],"media":[{"alt":null,"id":1469087547435,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-204-am-s-8cc.jpg?v=1569268308"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-204-am-s-8cc.jpg?v=1569268308","width":1000},{"alt":null,"id":1469087678507,"position":2,"preview_image":{"aspect_ratio":1.038,"height":1445,"width":1500,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/71aSJm7BTZL._SL1500_-1.jpg?v=1569268308"},"aspect_ratio":1.038,"height":1445,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/71aSJm7BTZL._SL1500_-1.jpg?v=1569268308","width":1500}],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eAs the first four-channel portable scope safety rated CAT III 1000V \/ CAT IV 600V, the Fluke ScopeMeter 190-204\/S combines an unprecedented level of performance, ruggedness, and portability with 200 MHz bandwidth and real-time sampling rates up to 2.5 GS\/s and 200 ps resolution to capture noise and other disturbances. This model features deep memory up to 10,000 samples per channel; so you can examine very small parts of the waveform in detail, and it is IP-51 rated to withstand dust, drips, humidity, and wide temperature variations.\u003c\/span\u003e"}
Fluke 190-204/AM/S ScopeMeter® with Software

Fluke 190-204/AM/S ScopeMeter® with Software

$7,213.00 CAD

As the first four-channel portable scope safety rated CAT III 1000V / CAT IV 600V, the Fluke ScopeMeter 190-204/S combines an unprecedented level of performance, ruggedness, and portability with 200 MHz bandwidth and real-time sampling rates up to 2.5 GS/s and 200 ps resolution to capture noise and other disturbances. This model features deep me...


More Info
Fluke 190-204/AM ScopeMeter®

Oscilloscopes

$6,658.00 CAD
{"id":1069071335467,"title":"Fluke 190-204\/AM ScopeMeter®","handle":"fluke-190-204-scopemeter®","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eAs the first four-channel portable scope safety rated CAT III 1000 V \/ CAT IV 600 V, the Fluke ScopeMeter® 190-204 combines an unprecedented level of performance, ruggedness, and portability with 200 MHz bandwidth and real-time sampling rates up to 2.5 GS\/s and 200 ps resolution to capture noise and other disturbances. \u003c\/span\u003e","published_at":"2018-03-05T14:39:15-07:00","created_at":"2018-03-05T14:41:35-07:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":665800,"price_min":665800,"price_max":665800,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11000922734635,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-190-204\/AM","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190-204\/AM ScopeMeter®","public_title":null,"options":["Default Title"],"price":665800,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969579933"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/71aSJm7BTZL._SL1500.jpg?v=1520286096","\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke190-204-1.jpg?v=1520286097"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/71aSJm7BTZL._SL1500.jpg?v=1520286096","options":["Title"],"media":[{"alt":null,"id":1469002580011,"position":1,"preview_image":{"aspect_ratio":1.038,"height":1445,"width":1500,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/71aSJm7BTZL._SL1500.jpg?v=1569268177"},"aspect_ratio":1.038,"height":1445,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/71aSJm7BTZL._SL1500.jpg?v=1569268177","width":1500},{"alt":null,"id":1469002612779,"position":2,"preview_image":{"aspect_ratio":0.949,"height":1024,"width":972,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke190-204-1.jpg?v=1569268177"},"aspect_ratio":0.949,"height":1024,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke190-204-1.jpg?v=1569268177","width":972}],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eAs the first four-channel portable scope safety rated CAT III 1000 V \/ CAT IV 600 V, the Fluke ScopeMeter® 190-204 combines an unprecedented level of performance, ruggedness, and portability with 200 MHz bandwidth and real-time sampling rates up to 2.5 GS\/s and 200 ps resolution to capture noise and other disturbances. \u003c\/span\u003e"}
Fluke 190-204/AM ScopeMeter®

Fluke 190-204/AM ScopeMeter®

$6,658.00 CAD

As the first four-channel portable scope safety rated CAT III 1000 V / CAT IV 600 V, the Fluke ScopeMeter® 190-204 combines an unprecedented level of performance, ruggedness, and portability with 200 MHz bandwidth and real-time sampling rates up to 2.5 GS/s and 200 ps resolution to capture noise and other disturbances. 


More Info
Sold Out
Fluke 190-202/AM/S ScopeMeter® with Software
Fluke 190-202/AM/S ScopeMeter® with Software

Oscilloscopes

$6,242.00 CAD
{"id":1069078446123,"title":"Fluke 190-202\/AM\/S ScopeMeter® with Software","handle":"fluke-190-202-s-scopemeter®-with-software","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eAs the first two-channel portable scope safety rated CAT III 1000 V \/ CAT IV 600 V, the Fluke ScopeMeter 190-202\/S combines an unprecedented level of performance, ruggedness, and portability with 200 MHz bandwidth and real-time sampling rates up to 2.5 GS\/s and 200 ps resolution to capture noise and other disturbances. This model features deep memory up to 10,000 samples per channel; so you can examine very small parts of the waveform in detail, and it is IP-51 rated to withstand dust, drips, humidity, and wide temperature variations.\u003c\/span\u003e","published_at":"2018-03-05T14:42:06-07:00","created_at":"2018-03-05T14:45:58-07:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":624200,"price_min":624200,"price_max":624200,"available":false,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11000958222379,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-190-202\/AM\/S","requires_shipping":true,"taxable":true,"featured_image":null,"available":false,"name":"Fluke 190-202\/AM\/S ScopeMeter® with Software","public_title":null,"options":["Default Title"],"price":624200,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969601658"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/101722_GB_00_FB.EPS_1000.jpg?v=1520286359"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/101722_GB_00_FB.EPS_1000.jpg?v=1520286359","options":["Title"],"media":[{"alt":null,"id":1469007134763,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/101722_GB_00_FB.EPS_1000.jpg?v=1569268178"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/101722_GB_00_FB.EPS_1000.jpg?v=1569268178","width":1000}],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eAs the first two-channel portable scope safety rated CAT III 1000 V \/ CAT IV 600 V, the Fluke ScopeMeter 190-202\/S combines an unprecedented level of performance, ruggedness, and portability with 200 MHz bandwidth and real-time sampling rates up to 2.5 GS\/s and 200 ps resolution to capture noise and other disturbances. This model features deep memory up to 10,000 samples per channel; so you can examine very small parts of the waveform in detail, and it is IP-51 rated to withstand dust, drips, humidity, and wide temperature variations.\u003c\/span\u003e"}
Fluke 190-202/AM/S ScopeMeter® with Software

Fluke 190-202/AM/S ScopeMeter® with Software

$6,242.00 CAD

As the first two-channel portable scope safety rated CAT III 1000 V / CAT IV 600 V, the Fluke ScopeMeter 190-202/S combines an unprecedented level of performance, ruggedness, and portability with 200 MHz bandwidth and real-time sampling rates up to 2.5 GS/s and 200 ps resolution to capture noise and other disturbances. This model features deep m...


More Info
Fluke 190-202/AM ScopeMeter®

Oscilloscopes

$5,616.00 CAD
{"id":1069027950635,"title":"Fluke 190-202\/AM ScopeMeter®","handle":"fluke-190-202-scopemeter®","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eAs the first two-channel portable scope safety rated CAT III 1000V \/ CAT IV 600V, the Fluke ScopeMeter® 190-202 combines an unprecedented level of performance, ruggedness, and portability with 200 MHz bandwidth and real-time sampling rates up to 2.5GS\/s and 200 ps resolution to capture noise and other disturbances. This model feature deep memory up to 10,000 samples per channel; so you can examine very small parts of the waveform in detail, and it is IP-51 rated to withstand dust, drips, humidity, and wide temperature variations.\u003c\/span\u003e","published_at":"2018-03-05T13:58:26-07:00","created_at":"2018-03-05T14:04:39-07:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":561600,"price_min":561600,"price_max":561600,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11000665047083,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-190-202\/AM","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190-202\/AM ScopeMeter®","public_title":null,"options":["Default Title"],"price":561600,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969601573"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke190-202AMS.jpg?v=1520283881","\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-202-am-s-c05.jpg?v=1520283881"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke190-202AMS.jpg?v=1520283881","options":["Title"],"media":[{"alt":null,"id":1468958113835,"position":1,"preview_image":{"aspect_ratio":0.855,"height":768,"width":657,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke190-202AMS.jpg?v=1569268138"},"aspect_ratio":0.855,"height":768,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke190-202AMS.jpg?v=1569268138","width":657},{"alt":null,"id":1468958212139,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-202-am-s-c05.jpg?v=1569268138"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-202-am-s-c05.jpg?v=1569268138","width":1000}],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eAs the first two-channel portable scope safety rated CAT III 1000V \/ CAT IV 600V, the Fluke ScopeMeter® 190-202 combines an unprecedented level of performance, ruggedness, and portability with 200 MHz bandwidth and real-time sampling rates up to 2.5GS\/s and 200 ps resolution to capture noise and other disturbances. This model feature deep memory up to 10,000 samples per channel; so you can examine very small parts of the waveform in detail, and it is IP-51 rated to withstand dust, drips, humidity, and wide temperature variations.\u003c\/span\u003e"}
Fluke 190-202/AM ScopeMeter®

Fluke 190-202/AM ScopeMeter®

$5,616.00 CAD

As the first two-channel portable scope safety rated CAT III 1000V / CAT IV 600V, the Fluke ScopeMeter® 190-202 combines an unprecedented level of performance, ruggedness, and portability with 200 MHz bandwidth and real-time sampling rates up to 2.5GS/s and 200 ps resolution to capture noise and other disturbances. This model feature deep memory...


More Info
Fluke 190-104/AM/S ScopeMeter® with Software

Oscilloscopes

$6,380.00 CAD
{"id":1069050888235,"title":"Fluke 190-104\/AM\/S ScopeMeter® with Software","handle":"fluke-190-104-s-scopemeter®-with-software","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eAs the first two and four-channel portable scopes safety rated CAT III 1000V \/ CAT IV 600V, the new Fluke ScopeMeter® 190 Series II combines an unprecedented level of performance, ruggedness, and portability. You can choose from 60MHz, 100MHz or 200MHz bandwidth models, both with real-time sampling rates up to 2.5 GS\/s and 400 ps resolution to capture noise and other disturbances. Both models feature deep memory—up to 10,000 samples per channel— so you can examine very small parts of the waveform in detail. And both are IP-51 rated to withstand dust, drips, humidity, and wide temperature variations. Fluke ScopeMeter test tools are hand-held battery operated, designed to meet the demands of field service professionals.\u003c\/span\u003e","published_at":"2018-03-05T14:10:37-07:00","created_at":"2018-03-05T14:19:28-07:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":638000,"price_min":638000,"price_max":638000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11000771379243,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-190-104\/AM\/S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190-104\/AM\/S ScopeMeter® with Software","public_title":null,"options":["Default Title"],"price":638000,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969580144"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke_190-104_b3ac9f2b-e9a5-4c8e-ba2c-2e1e23bdd9c7.jpg?v=1520284770"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke_190-104_b3ac9f2b-e9a5-4c8e-ba2c-2e1e23bdd9c7.jpg?v=1520284770","options":["Title"],"media":[{"alt":null,"id":1468978004011,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke_190-104_b3ac9f2b-e9a5-4c8e-ba2c-2e1e23bdd9c7.jpg?v=1569268159"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke_190-104_b3ac9f2b-e9a5-4c8e-ba2c-2e1e23bdd9c7.jpg?v=1569268159","width":1024}],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eAs the first two and four-channel portable scopes safety rated CAT III 1000V \/ CAT IV 600V, the new Fluke ScopeMeter® 190 Series II combines an unprecedented level of performance, ruggedness, and portability. You can choose from 60MHz, 100MHz or 200MHz bandwidth models, both with real-time sampling rates up to 2.5 GS\/s and 400 ps resolution to capture noise and other disturbances. Both models feature deep memory—up to 10,000 samples per channel— so you can examine very small parts of the waveform in detail. And both are IP-51 rated to withstand dust, drips, humidity, and wide temperature variations. Fluke ScopeMeter test tools are hand-held battery operated, designed to meet the demands of field service professionals.\u003c\/span\u003e"}
Fluke 190-104/AM/S ScopeMeter® with Software

Fluke 190-104/AM/S ScopeMeter® with Software

$6,380.00 CAD

As the first two and four-channel portable scopes safety rated CAT III 1000V / CAT IV 600V, the new Fluke ScopeMeter® 190 Series II combines an unprecedented level of performance, ruggedness, and portability. You can choose from 60MHz, 100MHz or 200MHz bandwidth models, both with real-time sampling rates up to 2.5 GS/s and 400 ps resolution to c...


More Info
Fluke 190-104/AM ScopeMeter® Test Tool

Oscilloscopes

$5,826.00 CAD
{"id":1069017301035,"title":"Fluke 190-104\/AM ScopeMeter® Test Tool","handle":"fluke-190-104-scopemeter®-test-tool","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eAs the first four-channel portable scope safety rated CAT III 1000 V \/ CAT IV 600 V, the Fluke ScopeMeter® 190-104 combines an unprecedented level of performance, ruggedness, and portability. With 100 MHz bandwidth and real-time sampling rates up to 1.5 GS\/s and 200 ps resolution to capture noise and other disturbances.\u003c\/span\u003e","published_at":"2018-03-05T13:44:36-07:00","created_at":"2018-03-05T13:55:05-07:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":582600,"price_min":582600,"price_max":582600,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11000600428587,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-190-104\/AM","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190-104\/AM ScopeMeter® Test Tool","public_title":null,"options":["Default Title"],"price":582600,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969580076"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke_190-104.jpg?v=1520283307"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke_190-104.jpg?v=1520283307","options":["Title"],"media":[{"alt":null,"id":1468941402155,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke_190-104.jpg?v=1569268135"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke_190-104.jpg?v=1569268135","width":1024}],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eAs the first four-channel portable scope safety rated CAT III 1000 V \/ CAT IV 600 V, the Fluke ScopeMeter® 190-104 combines an unprecedented level of performance, ruggedness, and portability. With 100 MHz bandwidth and real-time sampling rates up to 1.5 GS\/s and 200 ps resolution to capture noise and other disturbances.\u003c\/span\u003e"}
Fluke 190-104/AM ScopeMeter® Test Tool

Fluke 190-104/AM ScopeMeter® Test Tool

$5,826.00 CAD

As the first four-channel portable scope safety rated CAT III 1000 V / CAT IV 600 V, the Fluke ScopeMeter® 190-104 combines an unprecedented level of performance, ruggedness, and portability. With 100 MHz bandwidth and real-time sampling rates up to 1.5 GS/s and 200 ps resolution to capture noise and other disturbances.


More Info
Fluke 190-102/AM/S ScopeMeter® with Software

Oscilloscopes

$5,687.00 CAD
{"id":1054491672619,"title":"Fluke 190-102\/AM\/S ScopeMeter® with Software","handle":"fluke-190-102-s-scopemeter®-with-software","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e\u003cspan\u003eAs the first two-channel portable scope safety rated CAT III 1000 V \/ CAT IV 600 V, the Fluke ScopeMeter 190-102\/S combines an unprecedented level of performance, ruggedness, and portability with 100 MHz bandwidth and real-time sampling rates up to 1.25 GS\/s and 200 ps resolution to capture noise and other disturbances. \u003c\/span\u003e\u003c\/span\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThis model features deep memory up to 10,000 samples per channel; so you can examine very small parts of the waveform in detail, and it is IP-51 rated to withstand dust, drips, humidity, and wide temperature variations. Fluke ScopeMeter test tools are hand-held battery operated, designed to meet the demands of field service professionals.\u003c\/span\u003e","published_at":"2018-02-27T12:29:09-07:00","created_at":"2018-02-27T12:34:27-07:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":568700,"price_min":568700,"price_max":568700,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":10857357082667,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-190-102\/AM\/S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190-102\/AM\/S ScopeMeter® with Software","public_title":null,"options":["Default Title"],"price":568700,"weight":0,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969601504"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-102-am-s-edf.jpg?v=1519760069"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-102-am-s-edf.jpg?v=1519760069","options":["Title"],"media":[{"alt":null,"id":1444207362091,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-102-am-s-edf.jpg?v=1569257588"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-102-am-s-edf.jpg?v=1569257588","width":1000}],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e\u003cspan\u003eAs the first two-channel portable scope safety rated CAT III 1000 V \/ CAT IV 600 V, the Fluke ScopeMeter 190-102\/S combines an unprecedented level of performance, ruggedness, and portability with 100 MHz bandwidth and real-time sampling rates up to 1.25 GS\/s and 200 ps resolution to capture noise and other disturbances. \u003c\/span\u003e\u003c\/span\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThis model features deep memory up to 10,000 samples per channel; so you can examine very small parts of the waveform in detail, and it is IP-51 rated to withstand dust, drips, humidity, and wide temperature variations. Fluke ScopeMeter test tools are hand-held battery operated, designed to meet the demands of field service professionals.\u003c\/span\u003e"}
Fluke 190-102/AM/S ScopeMeter® with Software

Fluke 190-102/AM/S ScopeMeter® with Software

$5,687.00 CAD

As the first two-channel portable scope safety rated CAT III 1000 V / CAT IV 600 V, the Fluke ScopeMeter 190-102/S combines an unprecedented level of performance, ruggedness, and portability with 100 MHz bandwidth and real-time sampling rates up to 1.25 GS/s and 200 ps resolution to capture noise and other disturbances. This model features deep ...


More Info
Fluke 190-102/AM ScopeMeter®

Oscilloscopes

$5,132.00 CAD
{"id":1052327641131,"title":"Fluke 190-102\/AM ScopeMeter®","handle":"fluke-190-102-scopemeter®","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e1.25 GS\/s sampling rate, 100MHz bandwidth with 2 input channels and DMM for industrial process control, automation or electronic applications.\u003c\/span\u003e","published_at":"2018-02-26T16:40:38-07:00","created_at":"2018-02-26T16:46:26-07:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":513200,"price_min":513200,"price_max":513200,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":10833802035243,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-190-102\/AM","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190-102\/AM ScopeMeter®","public_title":null,"options":["Default Title"],"price":513200,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969601436"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-102-am-s-e6f.jpg?v=1519688788"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-102-am-s-e6f.jpg?v=1519688788","options":["Title"],"media":[{"alt":null,"id":1439946637355,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-102-am-s-e6f.jpg?v=1569255756"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-190-102-am-s-e6f.jpg?v=1569255756","width":1000}],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e1.25 GS\/s sampling rate, 100MHz bandwidth with 2 input channels and DMM for industrial process control, automation or electronic applications.\u003c\/span\u003e"}
Fluke 190-102/AM ScopeMeter®

Fluke 190-102/AM ScopeMeter®

$5,132.00 CAD

1.25 GS/s sampling rate, 100MHz bandwidth with 2 input channels and DMM for industrial process control, automation or electronic applications.


More Info
Fluke 190-062/AM/S ScopeMeter® with Software

Oscilloscopes

$5,068.00 CAD
{"id":1038603649067,"title":"Fluke 190-062\/AM\/S ScopeMeter® with Software","handle":"fluke-190-062-s-scopemeter®-with-software","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eAs the first two-channel portable scope safety rated CAT III 1000 V \/ CAT IV 600 V, the Fluke ScopeMeter 190-062\/S combines an unprecedented level of performance, ruggedness, and portability with 60 MHz bandwidth and real-time sampling rates up to 625 MS\/s and 200 ps resolution to capture noise and other disturbances. This model feature deep memory up to 10,000 samples per channel; so you can examine very small parts of the waveform in detail, and it is IP-51 rated to withstand dust, drips, humidity, and wide temperature variations. Fluke ScopeMeter test tools are hand-held battery operated, designed to meet the demands of field service professionals.\u003c\/span\u003e","published_at":"2018-02-21T16:12:03-07:00","created_at":"2018-02-21T16:12:55-07:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":506800,"price_min":506800,"price_max":506800,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":10707950469163,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-190-026\/AM\/S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190-062\/AM\/S ScopeMeter® with Software","public_title":null,"options":["Default Title"],"price":506800,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969601368"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke190-062_0f57d4ba-d670-4d4a-91c5-73f9e3a98a3e.jpg?v=1519254777"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke190-062_0f57d4ba-d670-4d4a-91c5-73f9e3a98a3e.jpg?v=1519254777","options":["Title"],"media":[{"alt":null,"id":1417682419755,"position":1,"preview_image":{"aspect_ratio":0.869,"height":1024,"width":890,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke190-062_0f57d4ba-d670-4d4a-91c5-73f9e3a98a3e.jpg?v=1569246171"},"aspect_ratio":0.869,"height":1024,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke190-062_0f57d4ba-d670-4d4a-91c5-73f9e3a98a3e.jpg?v=1569246171","width":890}],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eAs the first two-channel portable scope safety rated CAT III 1000 V \/ CAT IV 600 V, the Fluke ScopeMeter 190-062\/S combines an unprecedented level of performance, ruggedness, and portability with 60 MHz bandwidth and real-time sampling rates up to 625 MS\/s and 200 ps resolution to capture noise and other disturbances. This model feature deep memory up to 10,000 samples per channel; so you can examine very small parts of the waveform in detail, and it is IP-51 rated to withstand dust, drips, humidity, and wide temperature variations. Fluke ScopeMeter test tools are hand-held battery operated, designed to meet the demands of field service professionals.\u003c\/span\u003e"}
Fluke 190-062/AM/S ScopeMeter® with Software

Fluke 190-062/AM/S ScopeMeter® with Software

$5,068.00 CAD

As the first two-channel portable scope safety rated CAT III 1000 V / CAT IV 600 V, the Fluke ScopeMeter 190-062/S combines an unprecedented level of performance, ruggedness, and portability with 60 MHz bandwidth and real-time sampling rates up to 625 MS/s and 200 ps resolution to capture noise and other disturbances. This model feature deep mem...


More Info
Fluke 190-062 ScopeMeter®

Oscilloscopes

$4,577.00 CAD
{"id":1038581104683,"title":"Fluke 190-062 ScopeMeter®","handle":"fluke-190-062-scopemeter®","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eAs the first two-channel portable scope safety rated CAT III 1000 V \/ CAT IV 600 V, the Fluke ScopeMeter® 190-062 combines an unprecedented level of performance, ruggedness, and portability with 60MHz bandwidth and real-time sampling rates up to 625 MS\/s and 200 ps resolution to capture noise and other disturbances. This model feature deep memory up to 10,000 samples per channel; so you can examine very small parts of the waveform in detail, and it is IP-51 rated to withstand dust, drips, humidity, and wide temperature variations. Fluke ScopeMeter® test tools are hand-held battery operated, designed to meet the demands of field service professionals.\u003c\/span\u003e","published_at":"2018-02-21T15:50:28-07:00","created_at":"2018-02-21T16:01:36-07:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":457700,"price_min":457700,"price_max":457700,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":10707776405547,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-190-062\/AM","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 190-062 ScopeMeter®","public_title":null,"options":["Default Title"],"price":457700,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969601290"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke190-062.jpg?v=1519254099"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke190-062.jpg?v=1519254099","options":["Title"],"media":[{"alt":null,"id":1417663447083,"position":1,"preview_image":{"aspect_ratio":0.869,"height":1024,"width":890,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke190-062.jpg?v=1569246167"},"aspect_ratio":0.869,"height":1024,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke190-062.jpg?v=1569246167","width":890}],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eAs the first two-channel portable scope safety rated CAT III 1000 V \/ CAT IV 600 V, the Fluke ScopeMeter® 190-062 combines an unprecedented level of performance, ruggedness, and portability with 60MHz bandwidth and real-time sampling rates up to 625 MS\/s and 200 ps resolution to capture noise and other disturbances. This model feature deep memory up to 10,000 samples per channel; so you can examine very small parts of the waveform in detail, and it is IP-51 rated to withstand dust, drips, humidity, and wide temperature variations. Fluke ScopeMeter® test tools are hand-held battery operated, designed to meet the demands of field service professionals.\u003c\/span\u003e"}
Fluke 190-062 ScopeMeter®

Fluke 190-062 ScopeMeter®

$4,577.00 CAD

As the first two-channel portable scope safety rated CAT III 1000 V / CAT IV 600 V, the Fluke ScopeMeter® 190-062 combines an unprecedented level of performance, ruggedness, and portability with 60MHz bandwidth and real-time sampling rates up to 625 MS/s and 200 ps resolution to capture noise and other disturbances. This model feature deep memor...


More Info
{"id":1253600526379,"title":"Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope, 2 Channel, 40 MHZ","handle":"fluke-125-industrial-scopemeter","description":"\u003cp\u003e\u003cspan\u003eThe compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input digital oscilloscope and multimeter\u003c\/li\u003e\n\u003cli\u003eIncreased resolution and work load coverage with 40 MHz oscilloscope bandwidth\u003c\/li\u003e\n\u003cli\u003eTwo 5,000-count true-rms digital multimeters\u003c\/li\u003e\n\u003cli\u003eConnect-and-View™ trigger simplicity for hands-off operation; IntellaSet™ technology automatically and intelligently adjusts numerical readout\u003c\/li\u003e\n\u003cli\u003eDual-input waveform and meter reading recorder for trending data over extended periods\u003c\/li\u003e\n\u003cli\u003eRecorder Event Detect captures elusive intermittent signals\u003c\/li\u003e\n\u003cli\u003eWiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app*\u003c\/li\u003e\n\u003cli\u003eFlukeView® ScopeMeter® Software for Windows® (FLU-125B\/NA\/S)\u003c\/li\u003e\n\u003cli\u003eCheck Industrial networks with BusHealth physical layer tests against defined reference levels\u003c\/li\u003e\n\u003cli\u003eSingle Phase Power Quality and Harmonics Analzyer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eOscilloscope mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency response - dc coupled\u003c\/td\u003e\n\u003ctd\u003eWithout probes and test leads (with BB120)\u003c\/td\u003e\n\u003ctd\u003e123B: dc to 20 MHz (-3 dB)\u003cbr\u003e124B and 125B: dc to 40 MHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith STL120-IV 1:1 shielded test leads\u003c\/td\u003e\n\u003ctd\u003eDC to 12.5 MHz (-3 dB) \/ dc to 20 MHz (-6 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith VP41 10:1 Probe\u003c\/td\u003e\n\u003ctd\u003e123B: dc to 20MHz (-3 dB)\u003cbr\u003e124B and 125B: dc to 40 MHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency response - ac coupled (lf roll off)\u003c\/td\u003e\n\u003ctd\u003eWithout probes and test leads\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith STL120-IV 1:1 shielded test leads\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith VP41 10:1 Probe\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise time, excluding probes, \u003cbr\u003etest leads\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e123B \u0026lt;17.5 ns\u003cbr\u003e124B and 125B \u0026lt;8.75 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003eWithout probes and test leads\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\/\/20 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith BB120\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\/\/24 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith STL120-IV 1:1 shielded test leads\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\/\/230 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith VP41 10:1 Probe\u003c\/td\u003e\n\u003ctd\u003e5 MΩ\/\/15.5 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 mV to 200 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog bandwidth limiter\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay modes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA, -A, B, -B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMax. input voltage A and B\u003c\/td\u003e\n\u003ctd\u003eDirect, with test leads, or with VP41 Probe\u003c\/td\u003e\n\u003ctd\u003e600 Vrms Cat IV, 750 Vrms maximum voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith BB120\u003c\/td\u003e\n\u003ctd\u003e600 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. floating voltage, from any terminal to ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 Vrms Cat IV, 750 Vrms up to 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScope modes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormal, Single, Roll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eRanges (normal)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eEquivalent sampling\u003c\/td\u003e\n\u003ctd\u003e123B: 20 ns to 500 ns\/div,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 10 ns to 500 ns\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eReal time sampling\u003c\/td\u003e\n\u003ctd\u003e1 μs to 5 s\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eSingle (real time)\u003c\/td\u003e\n\u003ctd\u003e1 μs to 5 s\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eRoll (real time)\u003c\/td\u003e\n\u003ctd\u003e1s to 60 s\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSampling rate (for both channels simultaneously)\u003c\/td\u003e\n\u003ctd\u003eEquivalent sampling (repetitive signals)\u003c\/td\u003e\n\u003ctd\u003eUp to 4 GS\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eReal time sampling 1 μs to 60 s\/div\u003c\/td\u003e\n\u003ctd\u003e40 MS\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eTrigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen update\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFree run, on trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA, B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eSensitivity A and B\u003c\/td\u003e\n\u003ctd\u003e@ DC to 5 MHz\u003c\/td\u003e\n\u003ctd\u003e0.5 divisions or 5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" rowspan=\"2\"\u003e@ 40 MHz\u003c\/td\u003e\n\u003ctd\u003e123B: 4 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 1.5 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" rowspan=\"2\"\u003e@ 60 MHz\u003c\/td\u003e\n\u003ctd\u003e123B: N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 4 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePositive, negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAdvanced scope functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eDisplay modes\u003c\/td\u003e\n\u003ctd\u003eNormal\u003c\/td\u003e\n\u003ctd\u003eCaptures up to 25 ns glitches and displays analog-like persistence waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eSmooth\u003c\/td\u003e\n\u003ctd\u003eSuppresses noise from a waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eGlitch off\u003c\/td\u003e\n\u003ctd\u003eDoes not capture glitches between samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEnvelope\u003c\/td\u003e\n\u003ctd\u003eRecords and displays the minimum and maximum of waveforms over time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto set (Connect-and-View™)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eContinuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eDual input meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eAdd 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe  uncertainty +1%. More than one waveform period must be visible on the screen.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eInput A and input B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC voltage (VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.5% +5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection (CMRR)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;100 dB @ dc, \u0026gt;60 dB @ 50, 60, or 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eTrue-rms voltages (V ac and V ac+dc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy for 5% to 100% of range (DC coupled)\u003c\/td\u003e\n\u003ctd\u003eDC to 60 Hz (V ac+dc)\u003c\/td\u003e\n\u003ctd\u003e±(1% +10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e1 Hz to 60 Hz (V ac)\u003c\/td\u003e\n\u003ctd\u003e±(1% +10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy for 5% to 100% of range (AC or dc coupled)\u003c\/td\u003e\n\u003ctd\u003e60 Hz to 20 kHz\u003c\/td\u003e\n\u003ctd\u003e±(2.5% +15 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC rejection (only VAC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;50 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCommon mode rejection (CMRR)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;100 dB @ dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e\u0026gt;60 dB @ 50, 60, or 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts, reading is independent of any signal crest factor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePeak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMax peak, Min peak, or pk-to-pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 2200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eAccuracy Max peak or Min peak\u003c\/td\u003e\n\u003ctd\u003e5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy Peak-to-Peak\u003c\/td\u003e\n\u003ctd\u003e10% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFrequency (Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 Hz (1 Hz) to 50 MHz in continuous autoset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @1 Hz to 1 MHz\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.5% +2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10,000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eRPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50.00 kRPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.5% +2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDuty cycle (PULSE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2% to 98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 Hz (1 Hz) to 30 MHz in continuous autoset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePulse width (PULSE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 Hz (1 Hz) to 30 MHz in continuous autoset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAmperes (AMP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eWith current clamp\u003c\/td\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd\u003eSame as V dc, V ac, V ac+dc, or PEAK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eScale factors\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\/A, 1 mV\/A, 10 mV\/A, 100 mV\/A, 400 mV\/A, 1 V\/A, 10 mV\/mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eSame as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eTemperature (TEMP) with optional temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e200 °C\/div (200 °F\/div)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale factor\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mV\/°C and 1 mV\/°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAs V dc (add temp. probe uncertainty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDecibel (dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 dBV\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 dBm (600 Ω \/50 Ω)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mW referenced to 600 Ω or 50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edB on\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eV dc, V ac, or Vac+dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eCrest factor (CREST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 to 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e90 Counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePhase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA to B, B to A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 359 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 degree\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePower (125B only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurations\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 phase \/ 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower factor (PF)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRatio between watts and VA range - 0.00 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eWatt\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRMS reading of multiplying corresponding samples of input A (volts) and input B (amperes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eFull scale reading\u003c\/td\u003e\n\u003ctd\u003e999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVA\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eVrms x Arms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eFull scale reading\u003c\/td\u003e\n\u003ctd\u003e999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVA reactive (var)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e√((VA)\u003csup\u003e2\u003c\/sup\u003e-W\u003csup\u003e2\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eFull scale reading\u003c\/td\u003e\n\u003ctd\u003e999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eVpwm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePurpose\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTo measure on pulse width modulated signals, like motor drive inverter outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinciple\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eReadings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAs Vrms for sinewave signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eInput A to common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eOhm (Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eRanges\u003c\/td\u003e\n\u003ctd\u003e123B and 124B\u003c\/td\u003e\n\u003ctd\u003e500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e125B\u003c\/td\u003e\n\u003ctd\u003e50 Ω, 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 Ω to 5 MΩ - 5000 counts, 30 MΩ - 3000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5 mA to 50 nA, decreases with increasing ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eContinuity (Cont)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeep\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;(30 Ω ±5 Ω) in 50 Ω range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection of shorts of\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≥1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMeasurement voltage\u003c\/td\u003e\n\u003ctd\u003e@0.5 mA\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;2.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e@open circuit\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+ on input A, - on COM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eCapacitance (CAP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 nF, 500 nF, 5 μF, 50 μF, 500 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 nA to 0.5 mA, increases with increasing ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAdvanced meter functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Set\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSet actual value to reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoHold (on A)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCaptures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixed decimal point\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eActivated by using attenuation keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eCursor Readout (124B and 125B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSources\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA, B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eSingle vertical line\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAverage, min and max readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAverage, min, max and time from start of readout (in ROLL mode; instrument in HOLD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eMin, max and time from start of readout (in RECORDER mode; instrument in HOLD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eHarmonics values in POWER QUALITY mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDual vertical lines\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePeak-peak, time distance and reciprocal time distance readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAverage, min, max and time distance readout (in ROLL mode; instrument in HOLD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDual horizontal lines\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eHigh, low and peak-peak readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise or fall time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTransition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only \u003cbr\u003epossible in single channel mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAs oscilloscope accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eRecorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMeter readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Speed\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMaximum 2 measurement\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size (min, max, average)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 M readings for 1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eWaveform record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum sample rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 K sample\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize Internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 M samples Recorded Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 minutes at 500 μs\/div\u003cbr\u003e11 hours at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5 G samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e11 hours at 500 μs\/div\u003cbr\u003e14 days at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003ePower Quality (125B only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWatt, VA, var, PF, DPF, Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eWatt, VA, var ranges (auto)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e250 W to 250 MW, 625 MW, 1.56 GW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: total (% r)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 6 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: fundamental (% f)\u003c\/td\u003e\n\u003ctd\u003e±(4% + 4 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDPF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00, ±0.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10.0 Hz to 15.0 kHz\u003cbr\u003e40.0 Hz to 70.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Harmonics\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDC to 51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings \/ Cursor readings \u003cbr\u003e(fundamental 40 Hz to 70 Hz)\u003c\/td\u003e\n\u003ctd\u003eVrms \/ Arms \/Watt\u003c\/td\u003e\n\u003ctd\u003eEach harmonic from fundamental maybe selected for individual readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eIncludes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eBusHealth tester (Fluke 125B only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSubtype\u003c\/td\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAS-i\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNEN-EN50295\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAN\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eISO-11898\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterbus S\u003c\/td\u003e\n\u003ctd\u003eRS-422\u003c\/td\u003e\n\u003ctd\u003eEIA-422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eModbus\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003ctd\u003eRS-232\/EIA-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eRS-485\u003c\/td\u003e\n\u003ctd\u003eRS-485\/EIA-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoundation Fieldbus\u003c\/td\u003e\n\u003ctd\u003eH1\u003c\/td\u003e\n\u003ctd\u003e61158 type 1, 31.25 kBit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eProfibus\u003c\/td\u003e\n\u003ctd\u003eDP\u003c\/td\u003e\n\u003ctd\u003eEIA-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003ePA\u003c\/td\u003e\n\u003ctd\u003e61158 type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eMiscellaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e5.7-inch color active matrix TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eWaveform Display\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003ctd\u003e10 div of 40 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eHorizontal\u003c\/td\u003e\n\u003ctd\u003e12 div of 40 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"9\"\u003ePower\u003c\/td\u003e\n\u003ctd\u003eExternal\u003c\/td\u003e\n\u003ctd\u003eVia Power Adapter BC430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eInput voltage\u003c\/td\u003e\n\u003ctd\u003e10 V DC to 21 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003e5 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eInput connector\u003c\/td\u003e\n\u003ctd\u003e5 mm jack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eInternal\u003c\/td\u003e\n\u003ctd\u003eVia Battery Pack BP290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eBattery power\u003c\/td\u003e\n\u003ctd\u003eRechargeable Li-Ion 10.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e7 hours with 50% backlight brightness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4 hours with test tool off,  7 hours with test tool on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAllowable ambient temp\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (32 to 104 °F) during charging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eInternal memory can store 20 data sets  (screen waveform and setup)\u003c\/td\u003e\n\u003ctd\u003eMicro SD card slot with optional SD card  (max size of 32 GB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e259 x 132 x 55 mm \u003cbr\u003e(10.2 x 5.2 x 2.15 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.4 kg (3.2 lb) including battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eOptically isolated\u003c\/td\u003e\n\u003ctd\u003eTransfer screen copies (bitmaps), settings and data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eUSB to PC\/laptop\u003c\/td\u003e\n\u003ctd\u003eOC4USB optically isolated USB adapter\/cable, (optional), using FlukeView® software for Windows®.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eOptional WiFi adapter\u003c\/td\u003e\n\u003ctd\u003eFast transfer of screen copies (bitmaps), settings and data to PC\/laptop, tablet, smartphone, etc. A USB port is provided for attaching the WiFi dongle. Do not use the USB port with a cable for safety reasons.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMIL-PRF-28800F, Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eBattery Operation\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003ePower Adapter Operation\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 °C (-4 to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eHumidity (Operating)\u003c\/td\u003e\n\u003ctd\u003e@ 0 to 10 °C (32 to 50 °F)\u003c\/td\u003e\n\u003ctd\u003eNon-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e@ 10 to 30 °C (50 to 86 °F)\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e@ 30 to 40 °C (86 to 104 °F)\u003c\/td\u003e\n\u003ctd\u003e75%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e@ 40 to 50 °C (104 to 122 °F)\u003c\/td\u003e\n\u003ctd\u003e45%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e@ -20 to 60 °C (-4 to 140 °F)\u003c\/td\u003e\n\u003ctd\u003eNon-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating at 3 km (10,000 feet)\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eOperating at 2 km (6,600 feet)\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e12 km (40,000 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eEMC electromagnetic compatibility\u003c\/td\u003e\n\u003ctd\u003eInternational\u003c\/td\u003e\n\u003ctd\u003eIEC 61326-1: Industrial, CISPR 11:  Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eWireless radio with adapter\u003c\/td\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e2412 MHz to 2462 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;100 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP51, ref: EN\/IEC60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1: Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-2-033: CAT IV 600 V\/CAT III 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eMax. input voltage input A and B\u003c\/td\u003e\n\u003ctd\u003eDirect on input or with leads\u003c\/td\u003e\n\u003ctd\u003e600 Vrms CAT IV for derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith Banana-to-BNC Adapter BB120\u003c\/td\u003e\n\u003ctd\u003e600 Vrms for derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eMax. floating voltage from any terminal to ground\u003c\/td\u003e\n\u003ctd\u003e600 Vrms Cat IV, 750 Vrms up to 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOscilloscope\u003c\/li\u003e\n\u003cli\u003eAccessory List\u003c\/li\u003e\n\u003cli\u003eCD\u003c\/li\u003e\n\u003cli\u003eSafety Manual\u003c\/li\u003e\n\u003cli\u003eBanana to BNC Adapter\u003c\/li\u003e\n\u003cli\u003ePower Adapter\u003c\/li\u003e\n\u003cli\u003eShield Test Leads W\/ Black Ground Leads\u003c\/li\u003e\n\u003cli\u003eTL175 Test Leads\u003c\/li\u003e\n\u003cli\u003eBattery\u003c\/li\u003e\n\u003cli\u003eWiFi Dongle\u003c\/li\u003e\n\u003cli\u003eLine Cord\u003c\/li\u003e\n\u003cli\u003e10:1 Voltage probe\u003c\/li\u003e\n\u003cli\u003eCurrent Clamp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_ScopeMeter_Brochure_-_120_Series_190_Series.PDF?1800\" target=\"_blank\" title=\"Fluke 125B Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 125B Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-05-11T17:01:32-06:00","created_at":"2018-05-11T17:03:43-06:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":350900,"price_min":350900,"price_max":406400,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12050314723371,"title":"FLU-125B\/NA","option1":"FLU-125B\/NA","option2":null,"option3":null,"sku":"FLU-125B\/NA","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope, 2 Channel, 40 MHZ - FLU-125B\/NA","public_title":"FLU-125B\/NA","options":["FLU-125B\/NA"],"price":350900,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969814898"},{"id":30251356618795,"title":"FLU-125B\/NA\/S","option1":"FLU-125B\/NA\/S","option2":null,"option3":null,"sku":"FLU-125B\/NA\/S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope, 2 Channel, 40 MHZ - FLU-125B\/NA\/S","public_title":"FLU-125B\/NA\/S","options":["FLU-125B\/NA\/S"],"price":406400,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969815130"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-125-1ce.jpg?v=1526079825"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-125-1ce.jpg?v=1526079825","options":["Model"],"media":[{"alt":null,"id":1647120023595,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-125-1ce.jpg?v=1569303105"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-125-1ce.jpg?v=1569303105","width":1000}],"content":"\u003cp\u003e\u003cspan\u003eThe compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input digital oscilloscope and multimeter\u003c\/li\u003e\n\u003cli\u003eIncreased resolution and work load coverage with 40 MHz oscilloscope bandwidth\u003c\/li\u003e\n\u003cli\u003eTwo 5,000-count true-rms digital multimeters\u003c\/li\u003e\n\u003cli\u003eConnect-and-View™ trigger simplicity for hands-off operation; IntellaSet™ technology automatically and intelligently adjusts numerical readout\u003c\/li\u003e\n\u003cli\u003eDual-input waveform and meter reading recorder for trending data over extended periods\u003c\/li\u003e\n\u003cli\u003eRecorder Event Detect captures elusive intermittent signals\u003c\/li\u003e\n\u003cli\u003eWiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app*\u003c\/li\u003e\n\u003cli\u003eFlukeView® ScopeMeter® Software for Windows® (FLU-125B\/NA\/S)\u003c\/li\u003e\n\u003cli\u003eCheck Industrial networks with BusHealth physical layer tests against defined reference levels\u003c\/li\u003e\n\u003cli\u003eSingle Phase Power Quality and Harmonics Analzyer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eOscilloscope mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency response - dc coupled\u003c\/td\u003e\n\u003ctd\u003eWithout probes and test leads (with BB120)\u003c\/td\u003e\n\u003ctd\u003e123B: dc to 20 MHz (-3 dB)\u003cbr\u003e124B and 125B: dc to 40 MHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith STL120-IV 1:1 shielded test leads\u003c\/td\u003e\n\u003ctd\u003eDC to 12.5 MHz (-3 dB) \/ dc to 20 MHz (-6 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith VP41 10:1 Probe\u003c\/td\u003e\n\u003ctd\u003e123B: dc to 20MHz (-3 dB)\u003cbr\u003e124B and 125B: dc to 40 MHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency response - ac coupled (lf roll off)\u003c\/td\u003e\n\u003ctd\u003eWithout probes and test leads\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith STL120-IV 1:1 shielded test leads\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith VP41 10:1 Probe\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise time, excluding probes, \u003cbr\u003etest leads\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e123B \u0026lt;17.5 ns\u003cbr\u003e124B and 125B \u0026lt;8.75 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003eWithout probes and test leads\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\/\/20 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith BB120\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\/\/24 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith STL120-IV 1:1 shielded test leads\u003c\/td\u003e\n\u003ctd\u003e1 MΩ\/\/230 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith VP41 10:1 Probe\u003c\/td\u003e\n\u003ctd\u003e5 MΩ\/\/15.5 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 mV to 200 V\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog bandwidth limiter\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay modes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA, -A, B, -B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMax. input voltage A and B\u003c\/td\u003e\n\u003ctd\u003eDirect, with test leads, or with VP41 Probe\u003c\/td\u003e\n\u003ctd\u003e600 Vrms Cat IV, 750 Vrms maximum voltage.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith BB120\u003c\/td\u003e\n\u003ctd\u003e600 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. floating voltage, from any terminal to ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 Vrms Cat IV, 750 Vrms up to 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScope modes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNormal, Single, Roll\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eRanges (normal)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eEquivalent sampling\u003c\/td\u003e\n\u003ctd\u003e123B: 20 ns to 500 ns\/div,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 10 ns to 500 ns\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eReal time sampling\u003c\/td\u003e\n\u003ctd\u003e1 μs to 5 s\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eSingle (real time)\u003c\/td\u003e\n\u003ctd\u003e1 μs to 5 s\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eRoll (real time)\u003c\/td\u003e\n\u003ctd\u003e1s to 60 s\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSampling rate (for both channels simultaneously)\u003c\/td\u003e\n\u003ctd\u003eEquivalent sampling (repetitive signals)\u003c\/td\u003e\n\u003ctd\u003eUp to 4 GS\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eReal time sampling 1 μs to 60 s\/div\u003c\/td\u003e\n\u003ctd\u003e40 MS\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eTrigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen update\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFree run, on trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA, B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eSensitivity A and B\u003c\/td\u003e\n\u003ctd\u003e@ DC to 5 MHz\u003c\/td\u003e\n\u003ctd\u003e0.5 divisions or 5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" rowspan=\"2\"\u003e@ 40 MHz\u003c\/td\u003e\n\u003ctd\u003e123B: 4 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 1.5 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" rowspan=\"2\"\u003e@ 60 MHz\u003c\/td\u003e\n\u003ctd\u003e123B: N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 4 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePositive, negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAdvanced scope functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eDisplay modes\u003c\/td\u003e\n\u003ctd\u003eNormal\u003c\/td\u003e\n\u003ctd\u003eCaptures up to 25 ns glitches and displays analog-like persistence waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eSmooth\u003c\/td\u003e\n\u003ctd\u003eSuppresses noise from a waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eGlitch off\u003c\/td\u003e\n\u003ctd\u003eDoes not capture glitches between samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEnvelope\u003c\/td\u003e\n\u003ctd\u003eRecords and displays the minimum and maximum of waveforms over time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto set (Connect-and-View™)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eContinuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eDual input meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eAdd 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe  uncertainty +1%. More than one waveform period must be visible on the screen.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eInput A and input B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC voltage (VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.5% +5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection (CMRR)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;100 dB @ dc, \u0026gt;60 dB @ 50, 60, or 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eTrue-rms voltages (V ac and V ac+dc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy for 5% to 100% of range (DC coupled)\u003c\/td\u003e\n\u003ctd\u003eDC to 60 Hz (V ac+dc)\u003c\/td\u003e\n\u003ctd\u003e±(1% +10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e1 Hz to 60 Hz (V ac)\u003c\/td\u003e\n\u003ctd\u003e±(1% +10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy for 5% to 100% of range (AC or dc coupled)\u003c\/td\u003e\n\u003ctd\u003e60 Hz to 20 kHz\u003c\/td\u003e\n\u003ctd\u003e±(2.5% +15 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC rejection (only VAC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;50 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCommon mode rejection (CMRR)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;100 dB @ dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e\u0026gt;60 dB @ 50, 60, or 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts, reading is independent of any signal crest factor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePeak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMax peak, Min peak, or pk-to-pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 2200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eAccuracy Max peak or Min peak\u003c\/td\u003e\n\u003ctd\u003e5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy Peak-to-Peak\u003c\/td\u003e\n\u003ctd\u003e10% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFrequency (Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 Hz (1 Hz) to 50 MHz in continuous autoset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @1 Hz to 1 MHz\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.5% +2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10,000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eRPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50.00 kRPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.5% +2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDuty cycle (PULSE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2% to 98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 Hz (1 Hz) to 30 MHz in continuous autoset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePulse width (PULSE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 Hz (1 Hz) to 30 MHz in continuous autoset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAmperes (AMP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eWith current clamp\u003c\/td\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd\u003eSame as V dc, V ac, V ac+dc, or PEAK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eScale factors\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\/A, 1 mV\/A, 10 mV\/A, 100 mV\/A, 400 mV\/A, 1 V\/A, 10 mV\/mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eSame as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eTemperature (TEMP) with optional temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e200 °C\/div (200 °F\/div)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale factor\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mV\/°C and 1 mV\/°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAs V dc (add temp. probe uncertainty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDecibel (dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 dBV\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 dBm (600 Ω \/50 Ω)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mW referenced to 600 Ω or 50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edB on\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eV dc, V ac, or Vac+dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eCrest factor (CREST)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 to 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e90 Counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePhase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA to B, B to A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 359 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 degree\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePower (125B only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurations\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 phase \/ 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower factor (PF)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRatio between watts and VA range - 0.00 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eWatt\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRMS reading of multiplying corresponding samples of input A (volts) and input B (amperes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eFull scale reading\u003c\/td\u003e\n\u003ctd\u003e999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVA\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eVrms x Arms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eFull scale reading\u003c\/td\u003e\n\u003ctd\u003e999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVA reactive (var)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e√((VA)\u003csup\u003e2\u003c\/sup\u003e-W\u003csup\u003e2\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eFull scale reading\u003c\/td\u003e\n\u003ctd\u003e999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eVpwm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePurpose\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTo measure on pulse width modulated signals, like motor drive inverter outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinciple\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eReadings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAs Vrms for sinewave signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eInput A to common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eOhm (Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eRanges\u003c\/td\u003e\n\u003ctd\u003e123B and 124B\u003c\/td\u003e\n\u003ctd\u003e500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e125B\u003c\/td\u003e\n\u003ctd\u003e50 Ω, 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 Ω to 5 MΩ - 5000 counts, 30 MΩ - 3000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5 mA to 50 nA, decreases with increasing ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eContinuity (Cont)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeep\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;(30 Ω ±5 Ω) in 50 Ω range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection of shorts of\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≥1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDiode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMeasurement voltage\u003c\/td\u003e\n\u003ctd\u003e@0.5 mA\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;2.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e@open circuit\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+ on input A, - on COM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eCapacitance (CAP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 nF, 500 nF, 5 μF, 50 μF, 500 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 nA to 0.5 mA, increases with increasing ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAdvanced meter functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero Set\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSet actual value to reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoHold (on A)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCaptures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixed decimal point\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eActivated by using attenuation keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eCursor Readout (124B and 125B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSources\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA, B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eSingle vertical line\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAverage, min and max readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAverage, min, max and time from start of readout (in ROLL mode; instrument in HOLD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eMin, max and time from start of readout (in RECORDER mode; instrument in HOLD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eHarmonics values in POWER QUALITY mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDual vertical lines\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePeak-peak, time distance and reciprocal time distance readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eAverage, min, max and time distance readout (in ROLL mode; instrument in HOLD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDual horizontal lines\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eHigh, low and peak-peak readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise or fall time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTransition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only \u003cbr\u003epossible in single channel mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAs oscilloscope accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eRecorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMeter readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Speed\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMaximum 2 measurement\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size (min, max, average)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 M readings for 1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eWaveform record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum sample rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 K sample\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize Internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 M samples Recorded Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 minutes at 500 μs\/div\u003cbr\u003e11 hours at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5 G samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e11 hours at 500 μs\/div\u003cbr\u003e14 days at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003ePower Quality (125B only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWatt, VA, var, PF, DPF, Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eWatt, VA, var ranges (auto)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e250 W to 250 MW, 625 MW, 1.56 GW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: total (% r)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 6 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: fundamental (% f)\u003c\/td\u003e\n\u003ctd\u003e±(4% + 4 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDPF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00, ±0.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10.0 Hz to 15.0 kHz\u003cbr\u003e40.0 Hz to 70.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Harmonics\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDC to 51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings \/ Cursor readings \u003cbr\u003e(fundamental 40 Hz to 70 Hz)\u003c\/td\u003e\n\u003ctd\u003eVrms \/ Arms \/Watt\u003c\/td\u003e\n\u003ctd\u003eEach harmonic from fundamental maybe selected for individual readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eIncludes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eBusHealth tester (Fluke 125B only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSubtype\u003c\/td\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAS-i\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNEN-EN50295\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAN\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eISO-11898\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterbus S\u003c\/td\u003e\n\u003ctd\u003eRS-422\u003c\/td\u003e\n\u003ctd\u003eEIA-422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eModbus\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003ctd\u003eRS-232\/EIA-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eRS-485\u003c\/td\u003e\n\u003ctd\u003eRS-485\/EIA-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFoundation Fieldbus\u003c\/td\u003e\n\u003ctd\u003eH1\u003c\/td\u003e\n\u003ctd\u003e61158 type 1, 31.25 kBit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eProfibus\u003c\/td\u003e\n\u003ctd\u003eDP\u003c\/td\u003e\n\u003ctd\u003eEIA-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003ePA\u003c\/td\u003e\n\u003ctd\u003e61158 type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eMiscellaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e5.7-inch color active matrix TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eWaveform Display\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003ctd\u003e10 div of 40 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eHorizontal\u003c\/td\u003e\n\u003ctd\u003e12 div of 40 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"9\"\u003ePower\u003c\/td\u003e\n\u003ctd\u003eExternal\u003c\/td\u003e\n\u003ctd\u003eVia Power Adapter BC430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eInput voltage\u003c\/td\u003e\n\u003ctd\u003e10 V DC to 21 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003e5 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eInput connector\u003c\/td\u003e\n\u003ctd\u003e5 mm jack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eInternal\u003c\/td\u003e\n\u003ctd\u003eVia Battery Pack BP290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eBattery power\u003c\/td\u003e\n\u003ctd\u003eRechargeable Li-Ion 10.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eOperating time\u003c\/td\u003e\n\u003ctd\u003e7 hours with 50% backlight brightness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eCharging time\u003c\/td\u003e\n\u003ctd\u003e4 hours with test tool off,  7 hours with test tool on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAllowable ambient temp\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (32 to 104 °F) during charging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eInternal memory can store 20 data sets  (screen waveform and setup)\u003c\/td\u003e\n\u003ctd\u003eMicro SD card slot with optional SD card  (max size of 32 GB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMechanical\u003c\/td\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e259 x 132 x 55 mm \u003cbr\u003e(10.2 x 5.2 x 2.15 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.4 kg (3.2 lb) including battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eOptically isolated\u003c\/td\u003e\n\u003ctd\u003eTransfer screen copies (bitmaps), settings and data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eUSB to PC\/laptop\u003c\/td\u003e\n\u003ctd\u003eOC4USB optically isolated USB adapter\/cable, (optional), using FlukeView® software for Windows®.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eOptional WiFi adapter\u003c\/td\u003e\n\u003ctd\u003eFast transfer of screen copies (bitmaps), settings and data to PC\/laptop, tablet, smartphone, etc. A USB port is provided for attaching the WiFi dongle. Do not use the USB port with a cable for safety reasons.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMIL-PRF-28800F, Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eBattery Operation\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C (32 to 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003ePower Adapter Operation\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 °C (-4 to 140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eHumidity (Operating)\u003c\/td\u003e\n\u003ctd\u003e@ 0 to 10 °C (32 to 50 °F)\u003c\/td\u003e\n\u003ctd\u003eNon-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e@ 10 to 30 °C (50 to 86 °F)\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e@ 30 to 40 °C (86 to 104 °F)\u003c\/td\u003e\n\u003ctd\u003e75%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e@ 40 to 50 °C (104 to 122 °F)\u003c\/td\u003e\n\u003ctd\u003e45%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e@ -20 to 60 °C (-4 to 140 °F)\u003c\/td\u003e\n\u003ctd\u003eNon-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating at 3 km (10,000 feet)\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eOperating at 2 km (6,600 feet)\u003c\/td\u003e\n\u003ctd\u003eCAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e12 km (40,000 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eEMC electromagnetic compatibility\u003c\/td\u003e\n\u003ctd\u003eInternational\u003c\/td\u003e\n\u003ctd\u003eIEC 61326-1: Industrial, CISPR 11:  Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eKorea (KCC)\u003c\/td\u003e\n\u003ctd\u003eClass A Equipment (Industrial Broadcasting \u0026amp; Communication Equipment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eUSA (FCC)\u003c\/td\u003e\n\u003ctd\u003e47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eWireless radio with adapter\u003c\/td\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e2412 MHz to 2462 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eOutput power\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;100 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP51, ref: EN\/IEC60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eGeneral\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1: Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-2-033: CAT IV 600 V\/CAT III 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eMax. input voltage input A and B\u003c\/td\u003e\n\u003ctd\u003eDirect on input or with leads\u003c\/td\u003e\n\u003ctd\u003e600 Vrms CAT IV for derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWith Banana-to-BNC Adapter BB120\u003c\/td\u003e\n\u003ctd\u003e600 Vrms for derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eMax. floating voltage from any terminal to ground\u003c\/td\u003e\n\u003ctd\u003e600 Vrms Cat IV, 750 Vrms up to 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOscilloscope\u003c\/li\u003e\n\u003cli\u003eAccessory List\u003c\/li\u003e\n\u003cli\u003eCD\u003c\/li\u003e\n\u003cli\u003eSafety Manual\u003c\/li\u003e\n\u003cli\u003eBanana to BNC Adapter\u003c\/li\u003e\n\u003cli\u003ePower Adapter\u003c\/li\u003e\n\u003cli\u003eShield Test Leads W\/ Black Ground Leads\u003c\/li\u003e\n\u003cli\u003eTL175 Test Leads\u003c\/li\u003e\n\u003cli\u003eBattery\u003c\/li\u003e\n\u003cli\u003eWiFi Dongle\u003c\/li\u003e\n\u003cli\u003eLine Cord\u003c\/li\u003e\n\u003cli\u003e10:1 Voltage probe\u003c\/li\u003e\n\u003cli\u003eCurrent Clamp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_ScopeMeter_Brochure_-_120_Series_190_Series.PDF?1800\" target=\"_blank\" title=\"Fluke 125B Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 125B Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope, 2 Channel, 40 MHZ

Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope, 2 Channel, 40 MHZ

$4,064.00 CAD

The compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with F...


More Info