Pressure Calibrators

Fluke 719 Pro Electric Pressure Calibrator

Pressure Calibrators

$5,067.00 CAD
{"id":1262557986859,"title":"Fluke 719 Pro Electric Pressure Calibrator","handle":"fluke-719-pro-electric-pressure-calibrator","description":"\u003cp\u003e\u003cstrong\u003eFluke 719Pro Electric Pressure Calibrator sources, simulates, and measures mA signals and more\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 719Pro includes a full functioning loop calibrator that sources, simulates and measures mA signals and more making it the ideal test tool for calibrating high accuracy transmitters, pressure switches and pressure gauges.\u003c\/p\u003e\n\u003cp\u003eGet the ultimate in measurement flexibility with the large backlit screen, which displays three parameters at once:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePressure measurement from internal or external sensor\u003c\/li\u003e\n\u003cli\u003eSourced\/simulated or measured mA values\u003c\/li\u003e\n\u003cli\u003eTemperature measured by optional RTD probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cul\u003e\n\u003cli\u003eUnique integrated electric pump for one handed pressure calibration\u003c\/li\u003e\n\u003cli\u003eTest pressure switches easily with easy-to-use switch test function\u003c\/li\u003e\n\u003cli\u003ePrecision pressure adjust vernier for easy and accurate pressure calibration\u003c\/li\u003e\n\u003cli\u003eIdeal accuracy and performance (0.025%) for reference class transmitter calibration\u003c\/li\u003e\n\u003cli\u003e30 psi, 150 psi and 300 psi pressure ranges\u003c\/li\u003e\n\u003cli\u003eProgrammable pressure calibrator pump limit:\n\u003cul\u003e\n\u003cli\u003eEliminates over-pressurization\u003c\/li\u003e\n\u003cli\u003eAllows the user to program target pressures for pumping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eExtended pressure measurement range with any of 29 750P Pressure Modules\u003c\/li\u003e\n\u003cli\u003ePump cleanout ports reduce pump failures from moisture and fluid damage\u003c\/li\u003e\n\u003cli\u003eFluid trap included with the unit to mitigate chance of fluid damage in at-risk applications\u003c\/li\u003e\n\u003cli\u003ePrecision temperature measurement with optional RTD probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eMeasurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eFluke-719Pro-30G\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-12 to 30 psi \/ -0.8 to 2 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.001 psi \/ 0.0001 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eFluke-719Pro-150G\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-12 to 150 psi \/ -0.8 to 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 psi \/ 0.001 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eFluke-719Pro-300G\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-12 to 300 psi \/ -0.8 to 20 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 psi \/ 0.001 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e±0.025% of full scale, 6 months\u003cbr\u003e±0.035% of full scale, 1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature effect (all ranges)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eAdd ±0.002% F.S.\/°C for temps outside of 15°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"4\"\u003eDry air and non-corrosive gas only\u003cbr\u003eNo effect on accuracy on all functions from 15°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy (1 year)\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA DC (simulation and measurement)\u003c\/td\u003e\n\u003ctd\u003e0-24 mA DC\u003c\/td\u003e\n\u003ctd\u003e0.001 mA\u003c\/td\u003e\n\u003ctd\u003e±0.015% of reading ±2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003e1000 ohm maximum load in mA source, 26 V DC maximum voltage in mA simulate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVolts DC (measurement only)\u003c\/td\u003e\n\u003ctd\u003e30 V DC\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003ctd\u003e±0.015% of reading ±2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eNo AC voltage measurement, do not exceed 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature (measurement only, Pt100 RTD)\u003c\/td\u003e\n\u003ctd\u003e-50 to 150°C\u003cbr\u003e(-50°F to 302°F)\u003c\/td\u003e\n\u003ctd\u003e0.01°C\u003cbr\u003e0.01°F\u003c\/td\u003e\n\u003ctd\u003eTemperature ±0.1°C (0.2°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"3\"\u003e±0.25°C (±0.45°F) combined uncertainty when using 720 RTD probe (optional accessory)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop power supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e24 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature effect (all functions)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eAdd ±0.002% F.S.\/°C for temps outside of 15°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"3\"\u003eNo effect on accuracy on all functions from 15°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eEnvironmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (with batteries)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003ePer battery manufacturer's specification within storage specification below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (without batteries)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003ePower Requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eEight (8) standard Alkaline AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e300 pump cycles to 150 psi minimum; 1000 pump cycles to 30 psi; 100 pump cycles to 300 psi minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003ePhysical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e24.13 x 11.18 x 7 cm (9.5 x 4.4 x 2.8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eWith holster 1.2 kg (2.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eConnections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1\/8 inch female NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard banana jacks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e4 pin miniature circular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal module\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e6 pin miniature circular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eEngineering Units (Configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003epsi, bar, mbar, kPa, kgcm\u003csup\u003e2\u003c\/sup\u003e, cmH\u003csub\u003e2\u003c\/sub\u003eO @ 4°C, cmH\u003csub\u003e2\u003c\/sub\u003eO @ 20°C, mH\u003csub\u003e2\u003c\/sub\u003eO @ 4°C, mH\u003csub\u003e2\u003c\/sub\u003eO @ 20°C, inH\u003csub\u003e2\u003c\/sub\u003eO @ 4°C, inH\u003csub\u003e2\u003c\/sub\u003eO @ 20°C, inH\u003csub\u003e2\u003c\/sub\u003eO @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH\u003csub\u003e2\u003c\/sub\u003eO @ 4°C, ftH\u003csub\u003e2\u003c\/sub\u003eO @ 20°C, ftH\u003csub\u003e2\u003c\/sub\u003eO @ 60°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest leads with alligator clips\u003c\/li\u003e\n\u003cli\u003ePrinted user's manual and user's manual on CD-ROM in 14 languages\u003c\/li\u003e\n\u003cli\u003eFluid trap\u003c\/li\u003e\n\u003cli\u003eCarrying case\u003c\/li\u003e\n\u003cli\u003e1\/4 inch NPT to 1\/4 inch ISO adapter\u003c\/li\u003e\n\u003cli\u003eAccessory hose kit with (2) 1\/8 inch quick fit adapters and 1 meter of hose\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/719PRO-Data_Sheet.PDF?1849\" target=\"_blank\" title=\"Fluke 719 Pro Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 719 Pro Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-05-16T11:40:23-06:00","created_at":"2018-05-16T11:44:21-06:00","vendor":"Fluke","type":"Pressure Calibrators","tags":[],"price":506700,"price_min":506700,"price_max":506700,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12139911315499,"title":"30PSI","option1":"30PSI","option2":null,"option3":null,"sku":"FLU-719PRO-30g","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 719 Pro Electric Pressure Calibrator - 30PSI","public_title":"30PSI","options":["30PSI"],"price":506700,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969673792"},{"id":15642163544107,"title":"150PSI","option1":"150PSI","option2":null,"option3":null,"sku":"FLU-719PRO-150G","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 719 Pro Electric Pressure Calibrator - 150PSI","public_title":"150PSI","options":["150PSI"],"price":506700,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969673808"},{"id":15642163576875,"title":"300PSI","option1":"300PSI","option2":null,"option3":null,"sku":"FLU-719PRO-300G","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 719 Pro Electric Pressure Calibrator - 300PSI","public_title":"300PSI","options":["300PSI"],"price":506700,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969673815"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-719-pro.jpg?v=1570134330","\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke-719Pro-300G-Electric-Pressure-Calibrator-1.jpg?v=1570134330"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-719-pro.jpg?v=1570134330","options":["Pressure Range"],"media":[{"alt":null,"id":2369751842859,"position":1,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-719-pro.jpg?v=1570134326"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-719-pro.jpg?v=1570134326","width":500},{"alt":null,"id":1663281659947,"position":2,"preview_image":{"aspect_ratio":0.774,"height":1550,"width":1200,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke-719Pro-300G-Electric-Pressure-Calibrator-1.jpg?v=1569305735"},"aspect_ratio":0.774,"height":1550,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke-719Pro-300G-Electric-Pressure-Calibrator-1.jpg?v=1569305735","width":1200}],"content":"\u003cp\u003e\u003cstrong\u003eFluke 719Pro Electric Pressure Calibrator sources, simulates, and measures mA signals and more\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 719Pro includes a full functioning loop calibrator that sources, simulates and measures mA signals and more making it the ideal test tool for calibrating high accuracy transmitters, pressure switches and pressure gauges.\u003c\/p\u003e\n\u003cp\u003eGet the ultimate in measurement flexibility with the large backlit screen, which displays three parameters at once:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePressure measurement from internal or external sensor\u003c\/li\u003e\n\u003cli\u003eSourced\/simulated or measured mA values\u003c\/li\u003e\n\u003cli\u003eTemperature measured by optional RTD probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cul\u003e\n\u003cli\u003eUnique integrated electric pump for one handed pressure calibration\u003c\/li\u003e\n\u003cli\u003eTest pressure switches easily with easy-to-use switch test function\u003c\/li\u003e\n\u003cli\u003ePrecision pressure adjust vernier for easy and accurate pressure calibration\u003c\/li\u003e\n\u003cli\u003eIdeal accuracy and performance (0.025%) for reference class transmitter calibration\u003c\/li\u003e\n\u003cli\u003e30 psi, 150 psi and 300 psi pressure ranges\u003c\/li\u003e\n\u003cli\u003eProgrammable pressure calibrator pump limit:\n\u003cul\u003e\n\u003cli\u003eEliminates over-pressurization\u003c\/li\u003e\n\u003cli\u003eAllows the user to program target pressures for pumping\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eExtended pressure measurement range with any of 29 750P Pressure Modules\u003c\/li\u003e\n\u003cli\u003ePump cleanout ports reduce pump failures from moisture and fluid damage\u003c\/li\u003e\n\u003cli\u003eFluid trap included with the unit to mitigate chance of fluid damage in at-risk applications\u003c\/li\u003e\n\u003cli\u003ePrecision temperature measurement with optional RTD probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eMeasurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eFluke-719Pro-30G\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-12 to 30 psi \/ -0.8 to 2 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.001 psi \/ 0.0001 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eFluke-719Pro-150G\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-12 to 150 psi \/ -0.8 to 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 psi \/ 0.001 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eFluke-719Pro-300G\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-12 to 300 psi \/ -0.8 to 20 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 psi \/ 0.001 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e±0.025% of full scale, 6 months\u003cbr\u003e±0.035% of full scale, 1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature effect (all ranges)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eAdd ±0.002% F.S.\/°C for temps outside of 15°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"4\"\u003eDry air and non-corrosive gas only\u003cbr\u003eNo effect on accuracy on all functions from 15°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy (1 year)\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA DC (simulation and measurement)\u003c\/td\u003e\n\u003ctd\u003e0-24 mA DC\u003c\/td\u003e\n\u003ctd\u003e0.001 mA\u003c\/td\u003e\n\u003ctd\u003e±0.015% of reading ±2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003e1000 ohm maximum load in mA source, 26 V DC maximum voltage in mA simulate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVolts DC (measurement only)\u003c\/td\u003e\n\u003ctd\u003e30 V DC\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003ctd\u003e±0.015% of reading ±2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eNo AC voltage measurement, do not exceed 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature (measurement only, Pt100 RTD)\u003c\/td\u003e\n\u003ctd\u003e-50 to 150°C\u003cbr\u003e(-50°F to 302°F)\u003c\/td\u003e\n\u003ctd\u003e0.01°C\u003cbr\u003e0.01°F\u003c\/td\u003e\n\u003ctd\u003eTemperature ±0.1°C (0.2°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"3\"\u003e±0.25°C (±0.45°F) combined uncertainty when using 720 RTD probe (optional accessory)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop power supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e24 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature effect (all functions)\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003eAdd ±0.002% F.S.\/°C for temps outside of 15°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"3\"\u003eNo effect on accuracy on all functions from 15°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eEnvironmental\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (with batteries)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003ePer battery manufacturer's specification within storage specification below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature (without batteries)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003ePower Requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eEight (8) standard Alkaline AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e300 pump cycles to 150 psi minimum; 1000 pump cycles to 30 psi; 100 pump cycles to 300 psi minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003ePhysical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e24.13 x 11.18 x 7 cm (9.5 x 4.4 x 2.8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eWith holster 1.2 kg (2.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eConnections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1\/8 inch female NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eStandard banana jacks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e4 pin miniature circular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal module\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e6 pin miniature circular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eEngineering Units (Configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003epsi, bar, mbar, kPa, kgcm\u003csup\u003e2\u003c\/sup\u003e, cmH\u003csub\u003e2\u003c\/sub\u003eO @ 4°C, cmH\u003csub\u003e2\u003c\/sub\u003eO @ 20°C, mH\u003csub\u003e2\u003c\/sub\u003eO @ 4°C, mH\u003csub\u003e2\u003c\/sub\u003eO @ 20°C, inH\u003csub\u003e2\u003c\/sub\u003eO @ 4°C, inH\u003csub\u003e2\u003c\/sub\u003eO @ 20°C, inH\u003csub\u003e2\u003c\/sub\u003eO @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH\u003csub\u003e2\u003c\/sub\u003eO @ 4°C, ftH\u003csub\u003e2\u003c\/sub\u003eO @ 20°C, ftH\u003csub\u003e2\u003c\/sub\u003eO @ 60°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest leads with alligator clips\u003c\/li\u003e\n\u003cli\u003ePrinted user's manual and user's manual on CD-ROM in 14 languages\u003c\/li\u003e\n\u003cli\u003eFluid trap\u003c\/li\u003e\n\u003cli\u003eCarrying case\u003c\/li\u003e\n\u003cli\u003e1\/4 inch NPT to 1\/4 inch ISO adapter\u003c\/li\u003e\n\u003cli\u003eAccessory hose kit with (2) 1\/8 inch quick fit adapters and 1 meter of hose\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/719PRO-Data_Sheet.PDF?1849\" target=\"_blank\" title=\"Fluke 719 Pro Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 719 Pro Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 719 Pro Electric Pressure Calibrator

Fluke 719 Pro Electric Pressure Calibrator

$5,067.00 CAD

Fluke 719Pro Electric Pressure Calibrator sources, simulates, and measures mA signals and more The 719Pro includes a full functioning loop calibrator that sources, simulates and measures mA signals and more making it the ideal test tool for calibrating high accuracy transmitters, pressure switches and pressure gauges. Get the ultimate in measure...


More Info
Fluke 718 Pressure Calibrator

Pressure Calibrators

$3,425.00 CAD
{"id":1078787080235,"title":"Fluke 718 Pressure Calibrator","handle":"fluke-718-pressure-calibrator","description":"\u003cp\u003e\u003cstrong\u003eThe complete solution to pressure calibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 718 Pressure Calibrator provides a total pressure calibration solution for transmitters, gauges and switches. This compact pressure calibration solution is about a third of the size of comparable instruments and weighs just one kilogram (two pounds). The unique easy to clean pump helps protect the pump from damage and provides the ability to service the pump without disassembly, even in the field.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cul\u003e\n\u003cli\u003ePressure Source and Milliamp Measurement to calibrate and maintain almost any pressure device\u003c\/li\u003e\n\u003cli\u003eIntegrated pump is easily cleaned when accidently exposed to fluids that reduces cost of ownership and repairs and enables servicing the pump in the field\u003c\/li\u003e\n\u003cli\u003eError % calculation for quicker pass\/fail decision making in the field\u003c\/li\u003e\n\u003cli\u003eBest in class mA accuracy of 0.015% for better measurement confidence and workload coverage\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Hold to capture changing measurements\u003c\/li\u003e\n\u003cli\u003eSwitch test feature for quicker and more accurate pressure switch testing\u003c\/li\u003e\n\u003cli\u003eNew 1 and 300 psi pressure ranges mean fewer extra tools required\u003c\/li\u003e\n\u003cli\u003e1, 30, 100 \u0026amp; 300 psi ranges now available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eFluke 718 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure pressure\u003c\/td\u003e\n\u003ctd\u003e(Internal sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.025% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctions\u003c\/td\u003e\n\u003ctd\u003eZero, min\/max, hold, damp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"2\"\u003eDry air, non-corrosives only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eFluke 718 1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-1 psi to +1 psi, -68.9 mbar to 68.9 mbar (-6.89 kPa to 6.89 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 psi, 0.001 mbar, 0.0001 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver pressure\u003c\/td\u003e\n\u003ctd\u003e5x Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctions\u003c\/td\u003e\n\u003ctd\u003eZero, Min, Max, Hold, Damp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eFluke 718 30G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-12 psi to 30 psi, (-850 mbar to 2 bar, -85 to 206.84 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 psi, 0.1 mbar, 0.01 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver pressure\u003c\/td\u003e\n\u003ctd\u003e5x Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctions\u003c\/td\u003e\n\u003ctd\u003eZero, Min, Max, Hold, Damp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eFluke 718 100G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-12 psi to 100 psi, (-850 mbar to 7 bar, -85 to 689.48 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 psi, 0.1 mbar, 0.01 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver pressure\u003c\/td\u003e\n\u003ctd\u003e2x Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctions\u003c\/td\u003e\n\u003ctd\u003eZero, Min, Max, Hold, Damp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eFluke 718 300G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-12 psi to 300 psi, (-850 mbar to 20 bar, -85 to 2068.42 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 psi, 1 mbar, 0.1 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver pressure\u003c\/td\u003e\n\u003ctd\u003e375 psi 25 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctions\u003c\/td\u003e\n\u003ctd\u003eZero, Min, Max, Hold, Damp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eFluke 718 series via 700 Series Pressure Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e29 pressure modules, 0 – 1 inH\u003csub\u003e2\u003c\/sub\u003e0 to 10,000 psi, 2.5 mbar to 700 bar. Over pressure per pressure module specs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003ePer pressure module specs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eTo 0.025% of full span, per pressure module specs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctions\u003c\/td\u003e\n\u003ctd\u003eZero, Min, Max, Hold, Damp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"2\"\u003eMedia compatibility per pressure module specs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eFluke 718 Series Via Built in Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-12 psi or -850 mbar to full scale Supported Pressure Units; psi, inH\u003csub\u003e2\u003c\/sub\u003e0 (4°C), inH\u003csub\u003e2\u003c\/sub\u003e0 (20°C), cmH\u003csub\u003e2\u003c\/sub\u003e0 (4°C), cmH\u003csub\u003e2\u003c\/sub\u003e0 (20°C), bar, mbar, kPa, inHg, mmHg, kg\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop power range\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"2\"\u003eDrive; 20 mA into 1000 Ω for battery \u0026gt; 6.8 V; 700 Ω for battery 5.8 to 6.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003emA Measure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 mA to 24 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.015% + 1 count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage\u003c\/td\u003e\n\u003ctd\u003e30 volts (non-operating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e95% (10°C to 30°C); 75% (30°C to 40°C); 45% (40°C to 50°C); 35% (50°C to 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e3,000 M max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e1 M drop test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eRandom, 2 g, 5 Hz – 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 1010.1: 1992\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN50082-1: 1992 and EN55022: 1994 Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e216 x 94 x 66 mm (8.50 x 3.72 x 2.60 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e992 g (35 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower, battery life\u003c\/td\u003e\n\u003ctd\u003e9V battery ANSI\/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e4 to 20 hours typical, depending on functions used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eThree years (one year on pressure pump in Fluke 718)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD, 5 digit pressure and current simultaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"2\"\u003eFor use with non-corrosive gasses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective Yellow Holster with test lead storage\u003c\/li\u003e\n\u003cli\u003eInstructions Sheet (14 languages)\u003c\/li\u003e\n\u003cli\u003eTest Leads and Alligator Clip\u003c\/li\u003e\n\u003cli\u003eTwo 9V alkaline batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_718_Calibrator_Spec.pdf?1848\" target=\"_blank\" title=\"Fluke 718 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 718 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-03-08T11:19:06-07:00","created_at":"2018-03-08T11:21:52-07:00","vendor":"Fluke","type":"Pressure Calibrators","tags":[],"price":342500,"price_min":342500,"price_max":342500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11061385265195,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-718","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 718 Pressure Calibrator","public_title":null,"options":["Default Title"],"price":342500,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-718-100g-a0b.jpg?v=1520533314"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-718-100g-a0b.jpg?v=1520533314","options":["Title"],"media":[{"alt":null,"id":1478718652459,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-718-100g-a0b.jpg?v=1569271883"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-718-100g-a0b.jpg?v=1569271883","width":1000}],"content":"\u003cp\u003e\u003cstrong\u003eThe complete solution to pressure calibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 718 Pressure Calibrator provides a total pressure calibration solution for transmitters, gauges and switches. This compact pressure calibration solution is about a third of the size of comparable instruments and weighs just one kilogram (two pounds). The unique easy to clean pump helps protect the pump from damage and provides the ability to service the pump without disassembly, even in the field.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cul\u003e\n\u003cli\u003ePressure Source and Milliamp Measurement to calibrate and maintain almost any pressure device\u003c\/li\u003e\n\u003cli\u003eIntegrated pump is easily cleaned when accidently exposed to fluids that reduces cost of ownership and repairs and enables servicing the pump in the field\u003c\/li\u003e\n\u003cli\u003eError % calculation for quicker pass\/fail decision making in the field\u003c\/li\u003e\n\u003cli\u003eBest in class mA accuracy of 0.015% for better measurement confidence and workload coverage\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Hold to capture changing measurements\u003c\/li\u003e\n\u003cli\u003eSwitch test feature for quicker and more accurate pressure switch testing\u003c\/li\u003e\n\u003cli\u003eNew 1 and 300 psi pressure ranges mean fewer extra tools required\u003c\/li\u003e\n\u003cli\u003e1, 30, 100 \u0026amp; 300 psi ranges now available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTechnical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eFluke 718 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure pressure\u003c\/td\u003e\n\u003ctd\u003e(Internal sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.025% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctions\u003c\/td\u003e\n\u003ctd\u003eZero, min\/max, hold, damp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"2\"\u003eDry air, non-corrosives only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eFluke 718 1G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-1 psi to +1 psi, -68.9 mbar to 68.9 mbar (-6.89 kPa to 6.89 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.0001 psi, 0.001 mbar, 0.0001 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver pressure\u003c\/td\u003e\n\u003ctd\u003e5x Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctions\u003c\/td\u003e\n\u003ctd\u003eZero, Min, Max, Hold, Damp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eFluke 718 30G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-12 psi to 30 psi, (-850 mbar to 2 bar, -85 to 206.84 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 psi, 0.1 mbar, 0.01 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver pressure\u003c\/td\u003e\n\u003ctd\u003e5x Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctions\u003c\/td\u003e\n\u003ctd\u003eZero, Min, Max, Hold, Damp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eFluke 718 100G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-12 psi to 100 psi, (-850 mbar to 7 bar, -85 to 689.48 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 psi, 0.1 mbar, 0.01 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver pressure\u003c\/td\u003e\n\u003ctd\u003e2x Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctions\u003c\/td\u003e\n\u003ctd\u003eZero, Min, Max, Hold, Damp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eFluke 718 300G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-12 psi to 300 psi, (-850 mbar to 20 bar, -85 to 2068.42 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 psi, 1 mbar, 0.1 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver pressure\u003c\/td\u003e\n\u003ctd\u003e375 psi 25 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctions\u003c\/td\u003e\n\u003ctd\u003eZero, Min, Max, Hold, Damp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eFluke 718 series via 700 Series Pressure Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e29 pressure modules, 0 – 1 inH\u003csub\u003e2\u003c\/sub\u003e0 to 10,000 psi, 2.5 mbar to 700 bar. Over pressure per pressure module specs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003ePer pressure module specs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eTo 0.025% of full span, per pressure module specs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctions\u003c\/td\u003e\n\u003ctd\u003eZero, Min, Max, Hold, Damp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"2\"\u003eMedia compatibility per pressure module specs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eFluke 718 Series Via Built in Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e-12 psi or -850 mbar to full scale Supported Pressure Units; psi, inH\u003csub\u003e2\u003c\/sub\u003e0 (4°C), inH\u003csub\u003e2\u003c\/sub\u003e0 (20°C), cmH\u003csub\u003e2\u003c\/sub\u003e0 (4°C), cmH\u003csub\u003e2\u003c\/sub\u003e0 (20°C), bar, mbar, kPa, inHg, mmHg, kg\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop power range\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"2\"\u003eDrive; 20 mA into 1000 Ω for battery \u0026gt; 6.8 V; 700 Ω for battery 5.8 to 6.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003emA Measure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0 mA to 24 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.015% + 1 count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage\u003c\/td\u003e\n\u003ctd\u003e30 volts (non-operating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e95% (10°C to 30°C); 75% (30°C to 40°C); 45% (40°C to 50°C); 35% (50°C to 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e3,000 M max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e1 M drop test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eRandom, 2 g, 5 Hz – 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No. 1010.1: 1992\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN50082-1: 1992 and EN55022: 1994 Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e216 x 94 x 66 mm (8.50 x 3.72 x 2.60 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e992 g (35 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower, battery life\u003c\/td\u003e\n\u003ctd\u003e9V battery ANSI\/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e4 to 20 hours typical, depending on functions used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eThree years (one year on pressure pump in Fluke 718)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD, 5 digit pressure and current simultaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"2\"\u003eFor use with non-corrosive gasses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProtective Yellow Holster with test lead storage\u003c\/li\u003e\n\u003cli\u003eInstructions Sheet (14 languages)\u003c\/li\u003e\n\u003cli\u003eTest Leads and Alligator Clip\u003c\/li\u003e\n\u003cli\u003eTwo 9V alkaline batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_718_Calibrator_Spec.pdf?1848\" target=\"_blank\" title=\"Fluke 718 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 718 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 718 Pressure Calibrator

Fluke 718 Pressure Calibrator

$3,425.00 CAD

The complete solution to pressure calibration The Fluke 718 Pressure Calibrator provides a total pressure calibration solution for transmitters, gauges and switches. This compact pressure calibration solution is about a third of the size of comparable instruments and weighs just one kilogram (two pounds). The unique easy to clean pump helps prot...


More Info
Fluke 721 Pressure Calibration Instrument

Pressure Calibrators

$3,507.00 CAD
{"id":1076371128363,"title":"Fluke 721 Pressure Calibration Instrument","handle":"fluke-721-precision-pressure-calibrator","description":"\u003cp\u003e\u003cstrong\u003eFluke 721 Precision Pressure Calibrator provides pressure calibration and temperature measurement for custody transfer applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 721 Precision Pressure Calibrator is the ideal tool for gas custody transfer applications. It features dual isolated pressure sensors to allow you to take simultaneous static and differential pressure measurements with a single tool. And it can be configured by selecting either a 16 psi (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then adding any of seven high pressure ranges: 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar).\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cul\u003e\n\u003cli\u003ePrecision pressure calibrator with dual isolated sensors for gas flow calibration (custody transfer) applications\u003c\/li\u003e\n\u003cli\u003eFeatures two isolated, stainless steel, pressure sensors with 0.025% accuracy\u003c\/li\u003e\n\u003cli\u003eIncludes Pt100 RTD input for temperature measurement (probe optional)\u003c\/li\u003e\n\u003cli\u003eMeasures 4 to 20 mA signals\u003c\/li\u003e\n\u003cli\u003eProvides internal 24 V loop power supply to power a transmitter under test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eSpecifications 1-Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eFluke-721-1601\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +16 psi,\u003cbr\u003e-0.97 bar to 1.1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-12 psi to +100 psi,\u003cbr\u003e-0.83 bar to 6.9 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-1603\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +16 psi,\u003cbr\u003e-0.97 bar to 1.1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-12 psi to +300 psi,\u003cbr\u003e-0.83 bar to 20 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-1605\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +16 psi,\u003cbr\u003e-0.97 bar to 1.1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-12 psi to +500 psi,\u003cbr\u003e-0.83 bar to 34.5 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-1610\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +16psi,\u003cbr\u003e-0.97 bar to 1.1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0 psi to +1000 psi,\u003cbr\u003e0.00 bar to 69 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eFluke-721-1615\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +16 psi,\u003cbr\u003e-0.97 bar to 1.1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0 psi to +1500 psi,\u003cbr\u003e0.00 bar to 103.4 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-1630\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +16 psi,\u003cbr\u003e-0.97 bar to 1.1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0 psi to +3000 psi,\u003cbr\u003e0.00 bar to 200 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-1650\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +16 psi,\u003cbr\u003e-0.97 bar to 1.1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0 psi to +5000 psi,\u003cbr\u003e0.00 bar to 345 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003e0.035% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eFluke-721-3601\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +36 psi,\u003cbr\u003e-0.97 bar to 2.48 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-12 to +100 psi,\u003cbr\u003e-0.83 bar to 6.9 bar\u003c\/td\u003e\n\u003ctd\u003e.01 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-3603\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +36 psi,\u003cbr\u003e-0.97 bar to 2.48 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-12 psi to +300 psi,\u003cbr\u003e-0.83 bar to 20 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-3605\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +36 psi,\u003cbr\u003e-0.97 bar to 2.48 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-12 psi to +500 psi,\u003cbr\u003e-0.83 bar to 34.5 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eFluke-721-3610\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +36 psi,\u003cbr\u003e-0.97 bar to 2.48 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0 psi to +1000 psi,\u003cbr\u003e0.00 bar to 69 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-3615\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +36 psi,\u003cbr\u003e-0.97 bar to 2.48 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0 psi to +1500 psi,\u003cbr\u003e0.00 bar to 103.4 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-3630\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +36 psi,\u003cbr\u003e-0.97 bar to 2.48 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0 psi to +3000 psi,\u003cbr\u003e0.00 bar to 200 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-3650\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +36 psi,\u003cbr\u003e-0.97 bar to 2.48 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0 psi to +5000 psi,\u003cbr\u003e0.00 bar to 345 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003e0.035% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument setup recall\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eLast used on power-up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eOperating temperature -10°C to +50°C\u003cbr\u003eStorage temperature (without batteries) -20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eIP-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower requirements\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e6.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026gt;35 hours, typical usage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries required\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e(4) Standard AA cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e7.9 x 4.3 x 2.3 in (20 x 11 x 5.8 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e03539 kg (1 lb 3 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\/ports pressure\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eTwo, 1\/8 in NPT, 700P Series Pressure Module; RTD Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eElectrical and Temperature Measurement 1-Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emA measure\u003c\/td\u003e\n\u003ctd\u003e0 to 24 mA\u003c\/td\u003e\n\u003ctd\u003e0.001 mA\u003c\/td\u003e\n\u003ctd\u003e±0.015% of rdg\u003cbr\u003e±0.002mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV DC measure\u003c\/td\u003e\n\u003ctd\u003e0 to 30 V DC\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003ctd\u003e±0.015% of rdg\u003cbr\u003e±0.002 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measure (RTD\/ Ohms)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e-40°C to 150°C\u003cbr\u003e(-40°F to 302°F)\u003c\/td\u003e\n\u003ctd\u003e0.01°C, 0.01°F\u003c\/td\u003e\n\u003ctd\u003e±0.015% of rdg\u003cbr\u003e±0.02 ohms\u003cbr\u003e±0.1°C (±0.2°F)\u003cbr\u003e±0.25°C (±0.45°F) combined uncertainty when using 720 RTD probe accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop power supply\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e24 mA @ 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"4\"\u003e1. Temperature measurement requires optional Fluke-720RTD Pt-100 RTD probe available as an accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eTemperature Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eNo effect on accuracy on all functions from 15°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eAdd ±0.002% F.S.\/°C for temps outside of 15°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eAvailable Pressure Engineering Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003epsi, bar, mbar, kPa, kgcm2, cmH\u003csub\u003e2\u003c\/sub\u003eO @ 4°C, cmH\u003csub\u003e2\u003c\/sub\u003eO @ 20°C, mH\u003csub\u003e2\u003c\/sub\u003eO @ 4°C, mH\u003csub\u003e2\u003c\/sub\u003eO @ 20°C, inH\u003csub\u003e2\u003c\/sub\u003eO @ 4°C, inH\u003csub\u003e2\u003c\/sub\u003eO @ 20°C, inH\u003csub\u003e2\u003c\/sub\u003eO @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH\u003csub\u003e2\u003c\/sub\u003eO @ 4°C, ftH\u003csub\u003e2\u003c\/sub\u003eO @ 20°C, ftH\u003csub\u003e2\u003c\/sub\u003eO @ 60°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSoft case\u003c\/li\u003e\n\u003cli\u003eFour (4) AA batteries\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_721-721EX_Spec.PDF?1850\" target=\"_blank\" title=\"Fluke 721 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 721 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-03-07T14:56:37-07:00","created_at":"2018-03-07T15:00:05-07:00","vendor":"Fluke","type":"Pressure Calibrators","tags":[],"price":350700,"price_min":350700,"price_max":350700,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11043582279723,"title":"36PSI\/3000PSI","option1":"36PSI\/3000PSI","option2":null,"option3":null,"sku":"FLU-721-3630","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 721 Pressure Calibration Instrument - 36PSI\/3000PSI","public_title":"36PSI\/3000PSI","options":["36PSI\/3000PSI"],"price":350700,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969674034"},{"id":15642174423083,"title":"36PSI\/5000PSI","option1":"36PSI\/5000PSI","option2":null,"option3":null,"sku":"FLU-721-3650","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 721 Pressure Calibration Instrument - 36PSI\/5000PSI","public_title":"36PSI\/5000PSI","options":["36PSI\/5000PSI"],"price":350700,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969674072"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/F-721_01b_c.jpg?v=1520460007"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/F-721_01b_c.jpg?v=1520460007","options":["Pressure Range"],"media":[{"alt":null,"id":1475978854443,"position":1,"preview_image":{"aspect_ratio":0.704,"height":1500,"width":1056,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/F-721_01b_c.jpg?v=1569271307"},"aspect_ratio":0.704,"height":1500,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/F-721_01b_c.jpg?v=1569271307","width":1056}],"content":"\u003cp\u003e\u003cstrong\u003eFluke 721 Precision Pressure Calibrator provides pressure calibration and temperature measurement for custody transfer applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 721 Precision Pressure Calibrator is the ideal tool for gas custody transfer applications. It features dual isolated pressure sensors to allow you to take simultaneous static and differential pressure measurements with a single tool. And it can be configured by selecting either a 16 psi (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then adding any of seven high pressure ranges: 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar).\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cul\u003e\n\u003cli\u003ePrecision pressure calibrator with dual isolated sensors for gas flow calibration (custody transfer) applications\u003c\/li\u003e\n\u003cli\u003eFeatures two isolated, stainless steel, pressure sensors with 0.025% accuracy\u003c\/li\u003e\n\u003cli\u003eIncludes Pt100 RTD input for temperature measurement (probe optional)\u003c\/li\u003e\n\u003cli\u003eMeasures 4 to 20 mA signals\u003c\/li\u003e\n\u003cli\u003eProvides internal 24 V loop power supply to power a transmitter under test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eSpecifications 1-Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eFluke-721-1601\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +16 psi,\u003cbr\u003e-0.97 bar to 1.1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-12 psi to +100 psi,\u003cbr\u003e-0.83 bar to 6.9 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-1603\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +16 psi,\u003cbr\u003e-0.97 bar to 1.1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-12 psi to +300 psi,\u003cbr\u003e-0.83 bar to 20 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-1605\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +16 psi,\u003cbr\u003e-0.97 bar to 1.1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-12 psi to +500 psi,\u003cbr\u003e-0.83 bar to 34.5 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-1610\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +16psi,\u003cbr\u003e-0.97 bar to 1.1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0 psi to +1000 psi,\u003cbr\u003e0.00 bar to 69 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eFluke-721-1615\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +16 psi,\u003cbr\u003e-0.97 bar to 1.1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0 psi to +1500 psi,\u003cbr\u003e0.00 bar to 103.4 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-1630\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +16 psi,\u003cbr\u003e-0.97 bar to 1.1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0 psi to +3000 psi,\u003cbr\u003e0.00 bar to 200 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-1650\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +16 psi,\u003cbr\u003e-0.97 bar to 1.1 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0 psi to +5000 psi,\u003cbr\u003e0.00 bar to 345 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003e0.035% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eFluke-721-3601\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +36 psi,\u003cbr\u003e-0.97 bar to 2.48 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-12 to +100 psi,\u003cbr\u003e-0.83 bar to 6.9 bar\u003c\/td\u003e\n\u003ctd\u003e.01 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-3603\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +36 psi,\u003cbr\u003e-0.97 bar to 2.48 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-12 psi to +300 psi,\u003cbr\u003e-0.83 bar to 20 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-3605\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +36 psi,\u003cbr\u003e-0.97 bar to 2.48 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-12 psi to +500 psi,\u003cbr\u003e-0.83 bar to 34.5 bar\u003c\/td\u003e\n\u003ctd\u003e0.01 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eFluke-721-3610\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +36 psi,\u003cbr\u003e-0.97 bar to 2.48 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0 psi to +1000 psi,\u003cbr\u003e0.00 bar to 69 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-3615\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +36 psi,\u003cbr\u003e-0.97 bar to 2.48 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0 psi to +1500 psi,\u003cbr\u003e0.00 bar to 103.4 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-3630\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +36 psi,\u003cbr\u003e-0.97 bar to 2.48 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0 psi to +3000 psi,\u003cbr\u003e0.00 bar to 200 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eFluke-721-3650\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eLow pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e-14 psi to +36 psi,\u003cbr\u003e-0.97 bar to 2.48 bar\u003c\/td\u003e\n\u003ctd\u003e0.001 psi,\u003cbr\u003e0.0001 bar\u003c\/td\u003e\n\u003ctd\u003e0.025% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eHigh pressure sensor\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e0 psi to +5000 psi,\u003cbr\u003e0.00 bar to 345 bar\u003c\/td\u003e\n\u003ctd\u003e0.1 psi,\u003cbr\u003e0.01 bar\u003c\/td\u003e\n\u003ctd\u003e0.035% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument setup recall\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eLast used on power-up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eOperating temperature -10°C to +50°C\u003cbr\u003eStorage temperature (without batteries) -20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress protection\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eIP-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower requirements\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e6.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e\u0026gt;35 hours, typical usage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries required\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e(4) Standard AA cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e7.9 x 4.3 x 2.3 in (20 x 11 x 5.8 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e03539 kg (1 lb 3 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\/ports pressure\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eTwo, 1\/8 in NPT, 700P Series Pressure Module; RTD Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eElectrical and Temperature Measurement 1-Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emA measure\u003c\/td\u003e\n\u003ctd\u003e0 to 24 mA\u003c\/td\u003e\n\u003ctd\u003e0.001 mA\u003c\/td\u003e\n\u003ctd\u003e±0.015% of rdg\u003cbr\u003e±0.002mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV DC measure\u003c\/td\u003e\n\u003ctd\u003e0 to 30 V DC\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003ctd\u003e±0.015% of rdg\u003cbr\u003e±0.002 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature measure (RTD\/ Ohms)\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e-40°C to 150°C\u003cbr\u003e(-40°F to 302°F)\u003c\/td\u003e\n\u003ctd\u003e0.01°C, 0.01°F\u003c\/td\u003e\n\u003ctd\u003e±0.015% of rdg\u003cbr\u003e±0.02 ohms\u003cbr\u003e±0.1°C (±0.2°F)\u003cbr\u003e±0.25°C (±0.45°F) combined uncertainty when using 720 RTD probe accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop power supply\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e24 mA @ 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"4\"\u003e1. Temperature measurement requires optional Fluke-720RTD Pt-100 RTD probe available as an accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eTemperature Effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eNo effect on accuracy on all functions from 15°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eAdd ±0.002% F.S.\/°C for temps outside of 15°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eAvailable Pressure Engineering Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003epsi, bar, mbar, kPa, kgcm2, cmH\u003csub\u003e2\u003c\/sub\u003eO @ 4°C, cmH\u003csub\u003e2\u003c\/sub\u003eO @ 20°C, mH\u003csub\u003e2\u003c\/sub\u003eO @ 4°C, mH\u003csub\u003e2\u003c\/sub\u003eO @ 20°C, inH\u003csub\u003e2\u003c\/sub\u003eO @ 4°C, inH\u003csub\u003e2\u003c\/sub\u003eO @ 20°C, inH\u003csub\u003e2\u003c\/sub\u003eO @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH\u003csub\u003e2\u003c\/sub\u003eO @ 4°C, ftH\u003csub\u003e2\u003c\/sub\u003eO @ 20°C, ftH\u003csub\u003e2\u003c\/sub\u003eO @ 60°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSoft case\u003c\/li\u003e\n\u003cli\u003eFour (4) AA batteries\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_721-721EX_Spec.PDF?1850\" target=\"_blank\" title=\"Fluke 721 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 721 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 721 Pressure Calibration Instrument

Fluke 721 Pressure Calibration Instrument

$3,507.00 CAD

Fluke 721 Precision Pressure Calibrator provides pressure calibration and temperature measurement for custody transfer applications The Fluke 721 Precision Pressure Calibrator is the ideal tool for gas custody transfer applications. It features dual isolated pressure sensors to allow you to take simultaneous static and differential pressure meas...


More Info
Crystal IS33 Pressure Calibrator

Pressure Calibrators

From $3,475.00 CAD
{"id":1281511129131,"title":"Crystal IS33 Pressure Calibrator","handle":"crystal-is33-36-5000-psi-pressure-calibrator","description":"\u003cp\u003eThe tried and true Crystal IS33 is a wide range digital pressure calibrator that fits easily into your shirt pocket. Offering both a high and low pressure port, its internal sensors give you 0.05% of reading accuracy and resist damage from over-pressure. The go-to for pressure and mA calibration.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e• Wide pressure range can measure vacuum and pressure up to 5000 psi (300 bar) \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Indicates milliamps to calibrate transmitters\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Ultra compact and light \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Very easy to learn and use \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Battery operated\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Brings laboratory accuracy to outdoor field conditions \u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e0 to 110% of Range\u003c\/strong\u003e: ±(0.05% of Reading + Floor Term)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFloor Term\u003c\/strong\u003e: 0.005% of FS or display resolution, whichever is greater\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVacuum\u003c\/strong\u003e: ±(0.25% of Reading + Vacuum Floor Term)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVacuum Floor Term\u003c\/strong\u003e: 0.004 psi for 16 and 36 psi 0.01 psi for 300 psi\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003emA Accuracy\u003c\/strong\u003e: ±(0.025% of Reading + 0.001 mA)\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eCrystal IS33 Pressure Calibrator with Protective Case\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Crystal_IS33_Specs.pdf?1433\" target=\"_blank\" title=\"Crystal IS33 Spec Sheet\" rel=\"noopener noreferrer\"\u003eCrystal IS33 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-05-25T10:43:43-06:00","created_at":"2018-05-25T10:48:04-06:00","vendor":"Crystal","type":"Pressure Calibrators","tags":[],"price":347500,"price_min":347500,"price_max":377500,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12260551000107,"title":"3KPSI","option1":"3KPSI","option2":null,"option3":null,"sku":"CRY-IS33-36\/3000","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Crystal IS33 Pressure Calibrator - 3KPSI","public_title":"3KPSI","options":["3KPSI"],"price":347500,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":""},{"id":14872763924523,"title":"5KPSI","option1":"5KPSI","option2":null,"option3":null,"sku":"CRY-IS33-36\/5000","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Crystal IS33 Pressure Calibrator - 5KPSI","public_title":"5KPSI","options":["5KPSI"],"price":377500,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Crystal-32-IS33.jpg?v=1527266886"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Crystal-32-IS33.jpg?v=1527266886","options":["Pressure Range"],"media":[{"alt":null,"id":1679517417515,"position":1,"preview_image":{"aspect_ratio":1.0,"height":870,"width":870,"src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Crystal-32-IS33.jpg?v=1569308328"},"aspect_ratio":1.0,"height":870,"media_type":"image","src":"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Crystal-32-IS33.jpg?v=1569308328","width":870}],"content":"\u003cp\u003eThe tried and true Crystal IS33 is a wide range digital pressure calibrator that fits easily into your shirt pocket. Offering both a high and low pressure port, its internal sensors give you 0.05% of reading accuracy and resist damage from over-pressure. The go-to for pressure and mA calibration.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e• Wide pressure range can measure vacuum and pressure up to 5000 psi (300 bar) \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Indicates milliamps to calibrate transmitters\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Ultra compact and light \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Very easy to learn and use \u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Battery operated\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e• Brings laboratory accuracy to outdoor field conditions \u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e0 to 110% of Range\u003c\/strong\u003e: ±(0.05% of Reading + Floor Term)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFloor Term\u003c\/strong\u003e: 0.005% of FS or display resolution, whichever is greater\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVacuum\u003c\/strong\u003e: ±(0.25% of Reading + Vacuum Floor Term)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVacuum Floor Term\u003c\/strong\u003e: 0.004 psi for 16 and 36 psi 0.01 psi for 300 psi\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003emA Accuracy\u003c\/strong\u003e: ±(0.025% of Reading + 0.001 mA)\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eCrystal IS33 Pressure Calibrator with Protective Case\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Crystal_IS33_Specs.pdf?1433\" target=\"_blank\" title=\"Crystal IS33 Spec Sheet\" rel=\"noopener noreferrer\"\u003eCrystal IS33 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Crystal IS33 Pressure Calibrator

Crystal IS33 Pressure Calibrator

$3,775.00 CAD

The tried and true Crystal IS33 is a wide range digital pressure calibrator that fits easily into your shirt pocket. Offering both a high and low pressure port, its internal sensors give you 0.05% of reading accuracy and resist damage from over-pressure. The go-to for pressure and mA calibration. Overview • Wide pressure range can measure vacuu...


More Info