{ "id":4461554925641, "title":"Hubner FOC signal transmission for HTL\/TTL (up to 100 kHz)","handle":"hubner-foc-signal-transmission-for-htl-ttl-up-to-100-khz", "description":"\u003ch4\u003eThe converters\u003c\/h4\u003e\n\u003cp\u003eFOC transmitters and FOC decoders are always installed when electric incremental signals are to be transmitted disturbance-free via fiber optic cables. They encode and transmit signals via a fiber optic cable to the decoder in the switchboard, where they can be used by the controller or other modules in the switchboard. In doing so they ensure high data transmission rates even over long cable lengths. Electrical isolation guarantees high levels of transmission reliability. It is possible to select HTL and\/or TTL as input blocks. Optional FOC cable break monitoring is available to increase system reliability. Many Hübner Giessen encoder solutions are optionally also available with an integrated FOC transmitter.\u003c\/p\u003e\n\u003ch1 style=\"text-align: center;\"\u003e*MADE IN GERMANY*\u003c\/h1\u003e\n\u003cp style=\"text-align: center;\"\u003eCall us today to find the best encoder for your application.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eModule set (transmitter + decoder) for incremental signals (HTL or TTL)\u003c\/li\u003e\n\u003cli\u003eAlternative: Combination of decoder module and encoder with integrated transmitter\u003c\/li\u003e\n\u003cli\u003eDisturbance-free signal transmission up to 1000 m range; signal conversion time 2 µs\u003c\/li\u003e\n\u003cli\u003eOptions: FOC break monitoring, galvanically isolated output blocks, aluminium die-cast housing for outdoor applications (IP66)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-responsive\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAttribute\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct usage\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eImplement FOC transmission path (Incremental)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e12-30 VDC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal input\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTransmitter LWLS-T (switchboard) uad LWL-T (housing for outdoor applications)\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eSignal input (from encoder): \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIncremental: 0°, 90°, N, STATUS; each with inverted signals\u003cbr\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSignal transmission (outputs transmitter module):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOptical (to decoder): Fiber optic 62.5\/125 µm or 50\/125 µm with ST plug-in connector\u003cbr\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSignal level:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHTL or TTL (RS 422A)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal output\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eDecoder LWLS-D and LWLS-Di (galvanically isolated output blocks)\u003cbr\u003e \u003c\/p\u003e\n\u003cp\u003eSignal output (to controller): \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIncremental: 0°, 90°, N, STATUS; each with inverted signals\u003c\/li\u003e\n\u003cli\u003e2 output blocks, optional additional galvanic isolation between the two output blocks (type LWLS-Di)\u003cbr\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSignal transmission (inputs decoder module):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOptical (from transmitter): Fiber optic 62.5\/125 µm or 50\/125 µm with ST plug-in connector. All data via only one optical fibre.\u003cbr\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSignal level:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHTL or TTL (2 output blocks, for each output block: HTL or TTL level)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0 - 100 kHz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCasing\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTransmitter\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLWLS-T: Electronic housing for standard mounting rails\u003c\/li\u003e\n\u003cli\u003eLWL-T: Die cast metal aluminium housing for outdoor applications\u003cbr\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDecoder\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLWLS-D(i): Electronic housing for standard mounting rails\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTransmitter\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLWLS-T: 23 x 120 x 115 mm\u003c\/li\u003e\n\u003cli\u003eLWL-T:  125 x 80 x 57 mm\u003cbr\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDecoder\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLWLS-D(i): 23 x 120 x 115 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice temperature range\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTransmitter\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLWLS-T: -20 °C to +70 °C\u003c\/li\u003e\n\u003cli\u003eLWL-T:  -25 °C to +85 °C\u003cbr\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDecoder\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLWLS-D(i): -20 °C to +70 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTransmitter\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLWLS-T: IP20 (switchboard)\u003c\/li\u003e\n\u003cli\u003eLWL-T: IP66 (outdoor area)\u003cbr\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDecoder\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLWLS-D(i): IP20 (switchboard)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical connection\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eTransmitter\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLWLS-T: Connection terminals and FOC connector outside\u003c\/li\u003e\n\u003cli\u003eLWL-T: Terminal box (terminal strip and FOC connector inside)\u003cbr\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDecoder\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLWLS-D(i): Connection terminals and FOC connector outside\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice options\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eConstant cycle time \u0026lt; 2 µs (transmitter input to decoder output)\u003c\/li\u003e\n\u003cli\u003eDistances up to 1000 m\u003c\/li\u003e\n\u003cli\u003eOptional cable break and status monitoring\u003c\/li\u003e\n\u003cli\u003e2 output blocks, optional additional galvanic isolation between the two output blocks (type LWLS-Di)\u003cbr\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical options\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAluminium die-cast housing for outdoor applications (Transmitter)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecial features and certificates\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNew transmission technology - patent pending\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e", "published_at":"2020-05-14T14:04:57", "created_at":"2020-05-14T14:04:57", "vendor":"Hubner", "type":"Encoder", "tags":[], "price":0, "price_min":0, "price_max":0, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[31512197595209], "variants":[{ "id":31512197595209, "product_id":4461554925641, "product_handle":"hubner-foc-signal-transmission-for-htl-ttl-up-to-100-khz", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Hubner FOC signal transmission for HTL\/TTL (up to 100 kHz) - Default Title", "options":["Default Title"], "price":0, "weight":4536, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":""}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/HubnerFOCTransmitter1.jpg?v=1589486853","\/\/kingswayinstruments.com\/cdn\/shop\/products\/HubnerFOCTransmitter2.jpg?v=1589486853"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/HubnerFOCTransmitter1.jpg?v=1589486853", "options":["Title"], "url":"\/products\/hubner-foc-signal-transmission-for-htl-ttl-up-to-100-khz"}

Hubner FOC signal transmission for HTL/TTL (up to 100 kHz)

Product Description

The converters

FOC transmitters and FOC decoders are always installed when electric incremental signals are to be transmitted disturbance-free via fiber optic cables. They encode and transmit signals via a fiber optic cable to the decoder in the switchboard, where they can be used by the controller or other modules in the switchboard. In doing so they ensure high data transmission rates even over long cable lengths. Electrical isolation guarantees high levels of transmission reliability. It is possible to select HTL and/or TTL as input blocks. Optional FOC cable break monitoring is available to increase system reliability. Many Hübner Giessen encoder solutions are optionally also available with an integrated FOC transmitter.

*MADE IN GERMANY*

Call us today to find the best encoder for your application.

Sku:
Vendor: Hubner
On Back-Order

  • Module set (transmitter + decoder) for incremental signals (HTL or TTL)
  • Alternative: Combination of decoder module and encoder with integrated transmitter
  • Disturbance-free signal transmission up to 1000 m range; signal conversion time 2 µs
  • Options: FOC break monitoring, galvanically isolated output blocks, aluminium die-cast housing for outdoor applications (IP66)
Attribute Value
Product usage

Implement FOC transmission path (Incremental)

Supply voltage

12-30 VDC

Signal input

Transmitter LWLS-T (switchboard) uad LWL-T (housing for outdoor applications)
 

Signal input (from encoder): 

  • Incremental: 0°, 90°, N, STATUS; each with inverted signals
     

Signal transmission (outputs transmitter module):

  • Optical (to decoder): Fiber optic 62.5/125 µm or 50/125 µm with ST plug-in connector
     

Signal level:

  • HTL or TTL (RS 422A)
Signal output

Decoder LWLS-D and LWLS-Di (galvanically isolated output blocks)
 

Signal output (to controller): 

  • Incremental: 0°, 90°, N, STATUS; each with inverted signals
  • 2 output blocks, optional additional galvanic isolation between the two output blocks (type LWLS-Di)
     

Signal transmission (inputs decoder module):

  • Optical (from transmitter): Fiber optic 62.5/125 µm or 50/125 µm with ST plug-in connector. All data via only one optical fibre.
     

Signal level:

  • HTL or TTL (2 output blocks, for each output block: HTL or TTL level)
Frequency range

0 - 100 kHz

Casing

Transmitter

  • LWLS-T: Electronic housing for standard mounting rails
  • LWL-T: Die cast metal aluminium housing for outdoor applications
     

Decoder

  • LWLS-D(i): Electronic housing for standard mounting rails
Dimensions

Transmitter

  • LWLS-T: 23 x 120 x 115 mm
  • LWL-T:  125 x 80 x 57 mm
     

Decoder

  • LWLS-D(i): 23 x 120 x 115 mm
Device temperature range

Transmitter

  • LWLS-T: -20 °C to +70 °C
  • LWL-T:  -25 °C to +85 °C
     

Decoder

  • LWLS-D(i): -20 °C to +70 °C
Degree of protection

Transmitter

  • LWLS-T: IP20 (switchboard)
  • LWL-T: IP66 (outdoor area)
     

Decoder

  • LWLS-D(i): IP20 (switchboard)
Electrical connection

Transmitter

  • LWLS-T: Connection terminals and FOC connector outside
  • LWL-T: Terminal box (terminal strip and FOC connector inside)
     

Decoder

  • LWLS-D(i): Connection terminals and FOC connector outside
Device options
  • Constant cycle time < 2 µs (transmitter input to decoder output)
  • Distances up to 1000 m
  • Optional cable break and status monitoring
  • 2 output blocks, optional additional galvanic isolation between the two output blocks (type LWLS-Di)
     
Mechanical options

Aluminium die-cast housing for outdoor applications (Transmitter)

Special features and certificates

New transmission technology - patent pending




Related Products