dwyer

{"id":7496149205182,"title":"Dwyer 475-1-FM Digital Manometer 0 to 20\" WC","handle":"dwyer-475-1-fm-digital-manometer-0-to-20-wc","description":"\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe \u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDwyer Series 475 Handheld Digital Manometer\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e measures positive, negative, or differential pressures of air and natural gases in ranges from 1 in w.c. (0.249 kPa) to 150 psid (10.34 bar). The dual push pads on the front panel control the on\/off, auto zero, and pressure unit selection, allowing for simple operation with no set up needed. When used with a Dwyer® Pitot tube, the Series 475 can also be used as an air velocity gage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e \u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRugged aluminum case protects instrument from damage during transport\/use\u003c\/li\u003e\n\u003cli\u003eLarge, easy to read LCD and simple operation\u003c\/li\u003e\n\u003cli\u003eFM approved to be intrinsically safe in hazardous locations, Class 1, Div 2, Groups A, B, C, D, T4 Ta = 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoring natural gas pressures on boilers and other combustion equipment\u003c\/li\u003e\n\u003cli\u003eField calibration of other instruments\u003c\/li\u003e\n\u003cli\u003eMonitoring or troubleshooting HVAC\/R systems\u003c\/li\u003e\n\u003cli\u003eAir velocity monitoring, when used with a Dwyer Pitot tube and AV calculator (sold separately)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 20.00\" w.c. (0 to 4.982 kPa)\u003cbr\u003eMax. Pressure: 10 psi (68.9 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService\u003c\/td\u003e\n\u003ctd\u003eAir and compatible combustible gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% F.S., 60 to 78°F (15.6 to 25.6°C)\u003cbr\u003e±1.5% F.S., from 32 to 60°F and 78 to 104°F (0 to 15.6°C and 25.6 to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Hysteresis\u003c\/td\u003e\n\u003ctd\u003e±0.1% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Limits\u003c\/td\u003e\n\u003ctd\u003e0 to 140°F (-17.8 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompensated Temperature Limits\u003c\/td\u003e\n\u003ctd\u003e32 to 104°F (0 to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4-digit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e9V alkaline battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connections\u003c\/td\u003e\n\u003ctd\u003eTwo barbed connections for use with 1\/8\" or 3\/16\" I.D. tubing\u003cbr\u003eTwo compression fittings for use with 1\/8\" I.D. x 1\/4\" O.D. tubing (for 100 psi or higher pressure ranges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCE, FM approved to CLASS 1, DIV. 2 GROUPS ABCD\/T4 Ta = 70°C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDwyer 475-1-FM Digital Manometer 0 to 20\" WC\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","published_at":"2022-12-08T13:11:41-07:00","created_at":"2022-12-08T13:11:40-07:00","vendor":"Dwyer","type":"","tags":[],"price":50500,"price_min":50500,"price_max":50500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":42385496473790,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"DWY-475-1-FM","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Dwyer 475-1-FM Digital Manometer 0 to 20\" WC","public_title":null,"options":["Default Title"],"price":50500,"weight":907,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Dwyer475.gif?v=1670530301"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Dwyer475.gif?v=1670530301","options":["Title"],"media":[{"alt":null,"id":25126239371454,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Dwyer475.gif?v=1670530301"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Dwyer475.gif?v=1670530301","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe \u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDwyer Series 475 Handheld Digital Manometer\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e measures positive, negative, or differential pressures of air and natural gases in ranges from 1 in w.c. (0.249 kPa) to 150 psid (10.34 bar). The dual push pads on the front panel control the on\/off, auto zero, and pressure unit selection, allowing for simple operation with no set up needed. When used with a Dwyer® Pitot tube, the Series 475 can also be used as an air velocity gage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e \u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRugged aluminum case protects instrument from damage during transport\/use\u003c\/li\u003e\n\u003cli\u003eLarge, easy to read LCD and simple operation\u003c\/li\u003e\n\u003cli\u003eFM approved to be intrinsically safe in hazardous locations, Class 1, Div 2, Groups A, B, C, D, T4 Ta = 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoring natural gas pressures on boilers and other combustion equipment\u003c\/li\u003e\n\u003cli\u003eField calibration of other instruments\u003c\/li\u003e\n\u003cli\u003eMonitoring or troubleshooting HVAC\/R systems\u003c\/li\u003e\n\u003cli\u003eAir velocity monitoring, when used with a Dwyer Pitot tube and AV calculator (sold separately)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 20.00\" w.c. (0 to 4.982 kPa)\u003cbr\u003eMax. Pressure: 10 psi (68.9 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService\u003c\/td\u003e\n\u003ctd\u003eAir and compatible combustible gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% F.S., 60 to 78°F (15.6 to 25.6°C)\u003cbr\u003e±1.5% F.S., from 32 to 60°F and 78 to 104°F (0 to 15.6°C and 25.6 to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Hysteresis\u003c\/td\u003e\n\u003ctd\u003e±0.1% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Limits\u003c\/td\u003e\n\u003ctd\u003e0 to 140°F (-17.8 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompensated Temperature Limits\u003c\/td\u003e\n\u003ctd\u003e32 to 104°F (0 to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4-digit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e9V alkaline battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connections\u003c\/td\u003e\n\u003ctd\u003eTwo barbed connections for use with 1\/8\" or 3\/16\" I.D. tubing\u003cbr\u003eTwo compression fittings for use with 1\/8\" I.D. x 1\/4\" O.D. tubing (for 100 psi or higher pressure ranges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCE, FM approved to CLASS 1, DIV. 2 GROUPS ABCD\/T4 Ta = 70°C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDwyer 475-1-FM Digital Manometer 0 to 20\" WC\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e"}
Dwyer 475-1-FM Digital Manometer 0 to 20" WC

Dwyer 475-1-FM Digital Manometer 0 to 20" WC

$505.00 CAD

The Dwyer Series 475 Handheld Digital Manometer measures positive, negative, or differential pressures of air and natural gases in ranges from 1 in w.c. (0.249 kPa) to 150 psid (10.34 bar). The dual push pads on the front panel control the on/off, auto zero, and pressure unit selection, allowing for simple operation with no set up needed. When u...


More Info
{"id":7496150548670,"title":"Dwyer 475-5-FM Digital Manometer 0 to 20 PSI","handle":"dwyer-475-5-fm-digital-manometer-0-to-20-psi","description":"\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe \u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDwyer Series 475 Handheld Digital Manometer\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e measures positive, negative, or differential pressures of air and natural gases in ranges from 1 in w.c. (0.249 kPa) to 150 psid (10.34 bar). The dual push pads on the front panel control the on\/off, auto zero, and pressure unit selection, allowing for simple operation with no set up needed. When used with a Dwyer® Pitot tube, the Series 475 can also be used as an air velocity gage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e \u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRugged aluminum case protects instrument from damage during transport\/use\u003c\/li\u003e\n\u003cli\u003eLarge, easy to read LCD and simple operation\u003c\/li\u003e\n\u003cli\u003eFM approved to be intrinsically safe in hazardous locations, Class 1, Div 2, Groups A, B, C, D, T4 Ta = 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoring natural gas pressures on boilers and other combustion equipment\u003c\/li\u003e\n\u003cli\u003eField calibration of other instruments\u003c\/li\u003e\n\u003cli\u003eMonitoring or troubleshooting HVAC\/R systems\u003c\/li\u003e\n\u003cli\u003eAir velocity monitoring, when used with a Dwyer Pitot tube and AV calculator (sold separately)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Ranges\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e0 to 20.00 psi (0 to 1.379 bar)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eMax. Pressure: 60 psi (4.14 bar)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService\u003c\/td\u003e\n\u003ctd\u003eAir and compatible combustible gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% F.S., 60 to 78°F (15.6 to 25.6°C)\u003cbr\u003e±1.5% F.S., from 32 to 60°F and 78 to 104°F (0 to 15.6°C and 25.6 to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Hysteresis\u003c\/td\u003e\n\u003ctd\u003e±0.1% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Limits\u003c\/td\u003e\n\u003ctd\u003e0 to 140°F (-17.8 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompensated Temperature Limits\u003c\/td\u003e\n\u003ctd\u003e32 to 104°F (0 to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4-digit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e9V alkaline battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connections\u003c\/td\u003e\n\u003ctd\u003eTwo barbed connections for use with 1\/8\" or 3\/16\" I.D. tubing\u003cbr\u003eTwo compression fittings for use with 1\/8\" I.D. x 1\/4\" O.D. tubing (for 100 psi or higher pressure ranges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCE, FM approved to CLASS 1, DIV. 2 GROUPS ABCD\/T4 Ta = 70°C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDwyer 475-1-FM Digital Manometer 0 to 20 PSI\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","published_at":"2022-12-08T13:15:02-07:00","created_at":"2022-12-08T13:15:02-07:00","vendor":"Dwyer","type":"","tags":[],"price":36500,"price_min":36500,"price_max":36500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":42385500111038,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"DWY-475-5-FM","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Dwyer 475-5-FM Digital Manometer 0 to 20 PSI","public_title":null,"options":["Default Title"],"price":36500,"weight":907,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Dwyer475_a2f766a6-8f96-4e89-b662-dfd296c472e4.gif?v=1670530504"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Dwyer475_a2f766a6-8f96-4e89-b662-dfd296c472e4.gif?v=1670530504","options":["Title"],"media":[{"alt":null,"id":25126251823294,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Dwyer475_a2f766a6-8f96-4e89-b662-dfd296c472e4.gif?v=1670530504"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Dwyer475_a2f766a6-8f96-4e89-b662-dfd296c472e4.gif?v=1670530504","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003eThe \u003c\/span\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDwyer Series 475 Handheld Digital Manometer\u003c\/strong\u003e\u003cspan data-mce-fragment=\"1\"\u003e measures positive, negative, or differential pressures of air and natural gases in ranges from 1 in w.c. (0.249 kPa) to 150 psid (10.34 bar). The dual push pads on the front panel control the on\/off, auto zero, and pressure unit selection, allowing for simple operation with no set up needed. When used with a Dwyer® Pitot tube, the Series 475 can also be used as an air velocity gage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e \u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRugged aluminum case protects instrument from damage during transport\/use\u003c\/li\u003e\n\u003cli\u003eLarge, easy to read LCD and simple operation\u003c\/li\u003e\n\u003cli\u003eFM approved to be intrinsically safe in hazardous locations, Class 1, Div 2, Groups A, B, C, D, T4 Ta = 70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMonitoring natural gas pressures on boilers and other combustion equipment\u003c\/li\u003e\n\u003cli\u003eField calibration of other instruments\u003c\/li\u003e\n\u003cli\u003eMonitoring or troubleshooting HVAC\/R systems\u003c\/li\u003e\n\u003cli\u003eAir velocity monitoring, when used with a Dwyer Pitot tube and AV calculator (sold separately)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Ranges\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e0 to 20.00 psi (0 to 1.379 bar)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eMax. Pressure: 60 psi (4.14 bar)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService\u003c\/td\u003e\n\u003ctd\u003eAir and compatible combustible gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% F.S., 60 to 78°F (15.6 to 25.6°C)\u003cbr\u003e±1.5% F.S., from 32 to 60°F and 78 to 104°F (0 to 15.6°C and 25.6 to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Hysteresis\u003c\/td\u003e\n\u003ctd\u003e±0.1% of FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Limits\u003c\/td\u003e\n\u003ctd\u003e0 to 140°F (-17.8 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompensated Temperature Limits\u003c\/td\u003e\n\u003ctd\u003e32 to 104°F (0 to 40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4-digit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e9V alkaline battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connections\u003c\/td\u003e\n\u003ctd\u003eTwo barbed connections for use with 1\/8\" or 3\/16\" I.D. tubing\u003cbr\u003eTwo compression fittings for use with 1\/8\" I.D. x 1\/4\" O.D. tubing (for 100 psi or higher pressure ranges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCE, FM approved to CLASS 1, DIV. 2 GROUPS ABCD\/T4 Ta = 70°C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDwyer 475-1-FM Digital Manometer 0 to 20 PSI\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e"}
Dwyer 475-5-FM Digital Manometer 0 to 20 PSI

Dwyer 475-5-FM Digital Manometer 0 to 20 PSI

$365.00 CAD

The Dwyer Series 475 Handheld Digital Manometer measures positive, negative, or differential pressures of air and natural gases in ranges from 1 in w.c. (0.249 kPa) to 150 psid (10.34 bar). The dual push pads on the front panel control the on/off, auto zero, and pressure unit selection, allowing for simple operation with no set up needed. When u...


More Info