Flir CM85-2 True RMS Power Clamp Meter
Product Description
The FLIR CM85-2 is an industrial power clamp meter with advanced power analysis and variable frequency drive (VFD) filtering functions required by electrical troubleshooters for full-scale equipment. Accurately analyze voltage in complex machinery by including harmonics, inrush, current, and phase rotation testing with a wide AC/DC voltage range and base accuracy of +/-1%. Stream live data in real time from the CM85-2 to your mobile device over Bluetooth®. Using the METERLiNK® app, you can compare log files, create alarm thresholds, visualize trends, and create reports to share with team members.
Overview
-
SUPERIOR POWER ANALYSIS
VFD mode increases accuracy when working on VFD-controlled equipment. Conduct multiple conductor measurements with True RMS AC Current up to 1000 Amps.
-
PURPOSE BUILT FOR INSPECTIONS
Dual LED lights eliminate the need to carry additional tools, and an ergonomic industrial design offers ease of use and operation.
-
INSPECT AT A SAFE DISTANCE
Stream live readings in real time from the meter to your mobile device over Bluetooth using the METERLiNK app from a distance up to 10 m (32 ft).
Specifications
OVERVIEW
-
MEASUREMENT & ANALYSIS
- AC Current
- 99.99 A, 50-60 Hz ± (2% + 5 digits); >60–400 Hz ± (2.5% + 5 digits)
999.9 A, 50-60 Hz ± (2% + 5 digits); >60–400 Hz ± (2.5% + 5 digits)
- AC Voltage
- 99.99 V, 50–500 Hz ±(1.0% + 5 digits)
999.9 V, 50–500 Hz ±(1.0% + 5 digits)
- Capacitance
- 3.999 μF, ±(1.9% + 8 digits)
39.99 μF, ±(1.9% + 8 digits)
399.9 μF, ±(1.9% + 8 digits)
3.999 mF, ±(1.9% + 8 digits)
- Continuity
- 999.9 Ω, ±(1.0% + 5 digits)
- DC Current
- 99.99 A, ±(2% + 0.5 A)
999.9 A, ±(2% + 5 digits)
- DC Voltage
- 99.99 V, ±(0.7% + 2 digits)
999.9 V, ±(0.7% + 2 digits)
- Diode
- 0.40 to 0.80 V, ±0.1 V
- Frequency
- 20.00 to 99.99 Hz, ±(0.5% + 3 digits)
20.0 to 999.9 Hz, ±(0.5% + 3 digits)
0.020 to 9.999 kHz, ±(0.5% + 3 digits)
- Harmonics
- Total harmonic distortion ACA/ACV: 99.9%, ±(3.0% + 10 digits)
Harmonic distortion: H01–H12 99.9%, ±(5% + 10 digits)
Harmonic distortion: H13–H25 99.9%, ±(10% + 10 digits)
- Inrush Current
- ACA:
99.99 A, ±(3% + 0.3 A)
999.9 A, ±(3% + 5 digits)
- Measuring Rate
- 3 times per second
- Peak Hold
- ACV:
140.0 V, ±(3.0% + 15 digits)
1400 V, ±(3.0% + 15 digits)
ACA:
140.0 A, ±(3.5% + 15 digits)
1400 A, ±(3.5% + 15 digits)
- Power Factor
- -1.00 to 0.00 to +1.00, ±3° ±1 digit
- Recording
- Data recording available via METERLiNK App
- Resistance
- 999.9 Ω, ±(1.0% + 5 digits)
9.999 kΩ, ±(1.0% + 3 digits)
99.99 kΩ, ±(1.0% + 3 digits)
- VFD
- ACV:
99.99 V, 50–60 Hz ±(1% + 5 digits)
999.9 V, 50–60 Hz ±(1% + 5 digits)
ACA:
99.99 A, 50–60 Hz ±(2% + 5 digits)
999.9 A, 50–60 Hz ±(2% + 5 digits)
- Watts
- DC:
9.999 kW (10 V, 5 A min), ±(3% + 0.05 kW)
99.99 kW (10 V, 5 A min), ±(3% + 0.5 kW)
999.9 kW (10 V, 5 A min), ±(3% + 10 digits)
AC:
9.999 kW (10 V, 5 A min), ±(3% + 10 digits)
99.99 kW (10 V, 5 A min), ±(3% + 10 digits)
999.9 kW (10 V, 5 A min), ±(3% + 10 digits)
What's in the Box
- True RMS Power Clamp
- Set of CAT IV-600V Test Leads
- 6 x LR03 Alkaline Batteries
- Quick Start Guide
- Warranty Card
- Limited Lifetime Warranty