{ "id":6179495084222, "title":"AEMC 403 True RMS Clamp Meter with Temperature, 1000A AC\/1500A DC","handle":"aemc-403-true-rms-clamp-meter-with-temperature-1000a-ac-1500a-dc", "description":"\u003cp\u003e\u003cspan\u003eThe True RMS Clamp-On Meter Model 403 is safety rated at 1000V CAT IV. It measures voltage, current, resistance, frequency, \u003c\/span\u003e\u003ca href=\"http:\/\/www.aemc.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003e\u003cstrong\u003e\u003cspan color=\"#004f92\" style=\"color: #004f92;\"\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003cspan\u003e\u003csup\u003e®\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003etemperature, and continuity. It can also perform diode checks. Adapter mode allows external sensor inputs to be displayed. Delta relative function allows new measurements to be compared to a reference value. This rugged meter can operate in demanding work environments, and its IP54 rating allows it to withstand both dust and water spray.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1000V CAT IV Rated\u003c\/li\u003e\n\u003cli\u003eUL 94 flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003eIP54 Rated\u003c\/li\u003e\n\u003cli\u003e10,000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1000VDC and AC and DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000AAC and 2000ADC\u003c\/li\u003e\n\u003cli\u003eMeasures temperature in °F or °C using a K-type Thermocouple\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC measurement voltage\u003c\/li\u003e\n\u003cli\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ecurrent measurement with 1mS capture\u003c\/li\u003e\n\u003cli\u003eDelta relative function for tracking deviation from reference values\u003c\/li\u003e\n\u003cli\u003eAdapter function to accept inputs from sensors and transducers with a millivolt output with user programmable scaling\u003c\/li\u003e\n\u003cli\u003eJaw opening up to 1.89\"\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1000Vrms AC\/DC Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1000Arms AC, 1500ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eInRush:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e10 to 1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eSelectable from 0 to 999.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e100kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eDiode Test:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e0 to 3.2VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e20kHz in V, 2kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eTemperature K Thermocouple:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e-76.0 to 2192°F (-60 to 1200°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eAdapter Function:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eLCD w\/backlight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eMIN\/MAX:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e4 x AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e\u0026gt;350 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e10.7 x 3.6 x 1.6\" (272 x 92 x 41mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1.32 lbs (600g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1.89\" (48mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e-4° to +131°F (-20° to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e-40° to +158°F (-40° to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eEN\/IEC 61010-1 to 1000V CAT IV\u003cimg src=\"https:\/\/www.aemc.com\/userfiles\/images\/logos\/CE_Logo.png\" alt=\"\"\u003e\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Clamp-on Meter\u003c\/li\u003e\n\u003cli\u003e2152.03 Silicone Lead Set, 1000V, CAT IV Rated\u003c\/li\u003e\n\u003cli\u003e2139.71 Type K Thermocouple\u003c\/li\u003e\n\u003cli\u003e2139.72 Soft Carrying Case\u003c\/li\u003e\n\u003cli\u003e4 x AA 1.2V Batteries\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_200-400-600_Series_Clamps_-_High_Current_Spec.pdf?v=1610036163\" target=\"_blank\" title=\"AEMC 403 True RMS Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 403 True RMS Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2021-01-18T10:47:38", "created_at":"2021-01-18T10:47:37", "vendor":"AEMC Instruments", "type":"Clamp Meters", "tags":[], "price":56700, "price_min":56700, "price_max":56700, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[37911301030078], "variants":[{ "id":37911301030078, "product_id":6179495084222, "product_handle":"aemc-403-true-rms-clamp-meter-with-temperature-1000a-ac-1500a-dc", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"AEMC-2139.21", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"AEMC 403 True RMS Clamp Meter with Temperature, 1000A AC\/1500A DC - Default Title", "options":["Default Title"], "price":56700, "weight":4082, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"685338110258"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC403Pic1.png?v=1610992059"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC403Pic1.png?v=1610992059", "options":["Title"], "url":"\/products\/aemc-403-true-rms-clamp-meter-with-temperature-1000a-ac-1500a-dc"}

AEMC 403 True RMS Clamp Meter with Temperature, 1000A AC/1500A DC

Product Description

The True RMS Clamp-On Meter Model 403 is safety rated at 1000V CAT IV. It measures voltage, current, resistance, frequency, True InRush®, temperature, and continuity. It can also perform diode checks. Adapter mode allows external sensor inputs to be displayed. Delta relative function allows new measurements to be compared to a reference value. This rugged meter can operate in demanding work environments, and its IP54 rating allows it to withstand both dust and water spray.

Sku: AEMC-2139.21
On Back-Order
$567.00 CAD

  • 1000V CAT IV Rated
  • UL 94 flame retardant self-extinguishing
  • IP54 Rated
  • 10,000-count blue electroluminescent backlit display
  • Measures up to 1000VAC (1400V peak), 1000VDC and AC and DC with resolution to 10mV
  • Measures up to 1000AAC and 2000ADC
  • Measures temperature in °F or °C using a K-type Thermocouple
  • Measures frequency to 20kHz with 0.1Hz resolution
  • Auto selects AC or DC measurement voltage
  • True InRush® current measurement with 1mS capture
  • Delta relative function for tracking deviation from reference values
  • Adapter function to accept inputs from sensors and transducers with a millivolt output with user programmable scaling
  • Jaw opening up to 1.89"
  • Leads are constructed with a flexible silicone material
Voltage Range: 1000Vrms AC/DC Autoranging
Resolution Max: 0.01V
Current Range: 1000Arms AC, 1500ADC
Resolution Max: 0.01A
Accuracy V Typical: 1% ± 3cts
Accuracy A Typical: 1% ± 3cts
InRush: 10 to 1000A
Continuity: Selectable from 0 to 999.9Ω
Resistance: 100kΩ
Diode Test: 0 to 3.2VDC
Frequency: 20kHz in V, 2kHz in A
Temperature K Thermocouple: -76.0 to 2192°F (-60 to 1200°C)
Adapter Function: Yes
LCD w/backlight: Yes
MIN/MAX: Yes
Power Source: 4 x AA, NEDA 15A, IEC LR6
Battery Life: >350 hours
Dimensions: 10.7 x 3.6 x 1.6" (272 x 92 x 41mm)
Weight: 1.32 lbs (600g) with batteries
Jaw Opening: 1.89" (48mm)
Operating Temperature: -4° to +131°F (-20° to +55°C)
Storage Temperature: -40° to +158°F (-40° to +70°C)
Operating Humidity: 90% up to 131°F (55°C)
Pollution Degree: 2
Ingress Protection: IP54
EMC: EN61326-1
Safety Compliance: EN/IEC 61010-1 to 1000V CAT IV
EN/IEC 61010-2-030:2010
EN/IEC 61010-032:2002


  • True RMS Clamp-on Meter
  • 2152.03 Silicone Lead Set, 1000V, CAT IV Rated
  • 2139.71 Type K Thermocouple
  • 2139.72 Soft Carrying Case
  • 4 x AA 1.2V Batteries
  • Manual