Clamp Meters

Fluke 374FC True-RMS AC/DC Clamp Meter

Clamp Meters

$720.79 CAD
{"id":1075877052459,"title":"Fluke 374FC True-RMS AC\/DC Clamp Meter","handle":"fluke-374fc-true-rms-ac-dc-clamp-meter","description":"\u003cp\u003e\u003cspan\u003eThe Fluke 374 FC Wireless True-rms AC\/DC Clamp Meter offers logging capabilities and measures up to 1000 V and 600 A, AC or DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConnect your meter to your smartphone with Fluke Connect Measurements\u003c\/li\u003e\n\u003cli\u003eRead measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks\u003c\/li\u003e\n\u003cli\u003eRecord results directly to your phone and the Cloud\u003c\/li\u003e\n\u003cli\u003eCapture intermittent faults while performing other tasks using the logging capabilities of the Fluke 374 FC\u003c\/li\u003e\n\u003cli\u003eCreate and share reports from the field via email, or converse in real-time with ShareLive™ video calls\u003c\/li\u003e\n\u003cli\u003eCompatible with TPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eIntegrated VFD low pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V safety rating\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Capability\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e600 A ac and dc current measurement\u003c\/li\u003e\n\u003cli\u003e1000 V ac and dc voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue-rms voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eResistance measurement to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000V, CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent AC Range\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC Range\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage AC\/DC Range\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003c!-- split --\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 374 FC TRMS AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003cli\u003eTL75 Test Leads\u003c\/li\u003e\n\u003cli\u003e2 x AA Alkaline Batteries\u003c\/li\u003e\n\u003cli\u003eCoated Instruction Card\u003c\/li\u003e\n\u003cli\u003eSafety Information Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_370_Series_FC_Spec.pdf?1825\" target=\"_blank\" title=\"Fluke 374FC Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 374FC Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-03-07T11:46:22-07:00","created_at":"2018-03-07T11:51:32-07:00","vendor":"Fluke","type":"Clamp Meters","tags":[],"price":72079,"price_min":72079,"price_max":72079,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11040295878699,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-374FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 374FC True-RMS AC\/DC Clamp Meter","public_title":null,"options":["Default Title"],"price":72079,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969798532","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/flu374fc-1-1.jpg?v=1520448694","\/\/kingswayinstruments.com\/cdn\/shop\/products\/FLUKE-374_FC_2-1.jpg?v=1520448695"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/flu374fc-1-1.jpg?v=1520448694","options":["Title"],"media":[{"alt":null,"id":1475596222507,"position":1,"preview_image":{"aspect_ratio":1.493,"height":1206,"width":1800,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/flu374fc-1-1.jpg?v=1520448694"},"aspect_ratio":1.493,"height":1206,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/flu374fc-1-1.jpg?v=1520448694","width":1800},{"alt":null,"id":1475596288043,"position":2,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FLUKE-374_FC_2-1.jpg?v=1520448695"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FLUKE-374_FC_2-1.jpg?v=1520448695","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Fluke 374 FC Wireless True-rms AC\/DC Clamp Meter offers logging capabilities and measures up to 1000 V and 600 A, AC or DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConnect your meter to your smartphone with Fluke Connect Measurements\u003c\/li\u003e\n\u003cli\u003eRead measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks\u003c\/li\u003e\n\u003cli\u003eRecord results directly to your phone and the Cloud\u003c\/li\u003e\n\u003cli\u003eCapture intermittent faults while performing other tasks using the logging capabilities of the Fluke 374 FC\u003c\/li\u003e\n\u003cli\u003eCreate and share reports from the field via email, or converse in real-time with ShareLive™ video calls\u003c\/li\u003e\n\u003cli\u003eCompatible with TPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eIntegrated VFD low pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V safety rating\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Capability\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e600 A ac and dc current measurement\u003c\/li\u003e\n\u003cli\u003e1000 V ac and dc voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue-rms voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eResistance measurement to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000V, CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent AC Range\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC Range\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage AC\/DC Range\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003c!-- split --\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 374 FC TRMS AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003cli\u003eTL75 Test Leads\u003c\/li\u003e\n\u003cli\u003e2 x AA Alkaline Batteries\u003c\/li\u003e\n\u003cli\u003eCoated Instruction Card\u003c\/li\u003e\n\u003cli\u003eSafety Information Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_370_Series_FC_Spec.pdf?1825\" target=\"_blank\" title=\"Fluke 374FC Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 374FC Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 374FC True-RMS AC/DC Clamp Meter

Fluke 374FC True-RMS AC/DC Clamp Meter

$720.79 CAD

The Fluke 374 FC Wireless True-rms AC/DC Clamp Meter offers logging capabilities and measures up to 1000 V and 600 A, AC or DC. Overview Connect your meter to your smartphone with Fluke Connect Measurements Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks Record results directly to your ...


More Info
Fluke 375FC True-RMS AC/DC Clamp Meter

Clamp Meters

$788.79 CAD
{"id":1072428548139,"title":"Fluke 375FC True-RMS AC\/DC Clamp Meter","handle":"fluke-375fc-true-rms-ac-dc-clamp-meter","description":"\u003cp\u003e\u003cspan\u003eThe Fluke 375 FC Wireless True-rms AC\/DC Clamp Meter offers logging capabilities and measures up to 1000 V and 600 A, AC or DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePerforming welding parameters? Then this is the perfect meter for you!\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConnect your meter to your smartphone with Fluke Connect Measurements\u003c\/li\u003e\n\u003cli\u003eRead measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks\u003c\/li\u003e\n\u003cli\u003eRecord results directly to your phone and the Cloud\u003c\/li\u003e\n\u003cli\u003eCapture intermittent faults while performing other tasks using the logging capabilities of the Fluke 375 FC\u003c\/li\u003e\n\u003cli\u003eCreate and share reports from the field via email, or converse in real-time with ShareLive™ video calls\u003c\/li\u003e\n\u003cli\u003eCompatible with iFlex flexible current probe; use to expand the measurement range to 2500 A ac; provides access to large conductors in tight spaces\u003c\/li\u003e\n\u003cli\u003eCompatible with TPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eIntegrated VFD low pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V safety rating\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Capability\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e600 A ac and dc current measurement\u003c\/li\u003e\n\u003cli\u003e2500 A ac current measurement with (optional) iFlex flexible current probe\u003c\/li\u003e\n\u003cli\u003e1000 V ac and dc voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue-rms voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eFrequency measurement to 500 Hz with body jaw and iFlex\u003c\/li\u003e\n\u003cli\u003eResistance measurement to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003e500 mV dc measurement range to interface with other accessories\u003c\/li\u003e\n\u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000V, CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent AC Range\u003c\/td\u003e\n\u003ctd\u003e600A with clamp jaws\u003cbr\u003e2500A with optional iFlex flexible current clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC Range\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage AC\/DC Range\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV DC Range\u003c\/td\u003e\n\u003ctd\u003e500mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOhms Range\u003c\/td\u003e\n\u003ctd\u003e60.00kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e5 to 500.0Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1μF to 1,000μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 375 FC TRMS AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003cli\u003eTL75 Test Leads\u003c\/li\u003e\n\u003cli\u003e2 x AA Alkaline Batteries\u003c\/li\u003e\n\u003cli\u003eCoated Instruction Card\u003c\/li\u003e\n\u003cli\u003eSafety Information Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_370_Series_FC_Spec.pdf?1825\" target=\"_blank\" title=\"Fluke 375FC Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 375FC Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-03-06T15:50:36-07:00","created_at":"2018-03-06T16:04:49-07:00","vendor":"Fluke","type":"Clamp Meters","tags":[],"price":78879,"price_min":78879,"price_max":78879,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11020039356459,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-375FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 375FC True-RMS AC\/DC Clamp Meter","public_title":null,"options":["Default Title"],"price":78879,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969798464","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/s-l1000-2.jpg?v=1520377491","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke-375-FC-True-rms-AC-DC-Clamp-Meter-1200x1200.jpg?v=1520377492"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/s-l1000-2.jpg?v=1520377491","options":["Title"],"media":[{"alt":null,"id":1472785252395,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/s-l1000-2.jpg?v=1520377491"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/s-l1000-2.jpg?v=1520377491","width":1000},{"alt":null,"id":1472785285163,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke-375-FC-True-rms-AC-DC-Clamp-Meter-1200x1200.jpg?v=1520377492"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke-375-FC-True-rms-AC-DC-Clamp-Meter-1200x1200.jpg?v=1520377492","width":1200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Fluke 375 FC Wireless True-rms AC\/DC Clamp Meter offers logging capabilities and measures up to 1000 V and 600 A, AC or DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePerforming welding parameters? Then this is the perfect meter for you!\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConnect your meter to your smartphone with Fluke Connect Measurements\u003c\/li\u003e\n\u003cli\u003eRead measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks\u003c\/li\u003e\n\u003cli\u003eRecord results directly to your phone and the Cloud\u003c\/li\u003e\n\u003cli\u003eCapture intermittent faults while performing other tasks using the logging capabilities of the Fluke 375 FC\u003c\/li\u003e\n\u003cli\u003eCreate and share reports from the field via email, or converse in real-time with ShareLive™ video calls\u003c\/li\u003e\n\u003cli\u003eCompatible with iFlex flexible current probe; use to expand the measurement range to 2500 A ac; provides access to large conductors in tight spaces\u003c\/li\u003e\n\u003cli\u003eCompatible with TPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eIntegrated VFD low pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V safety rating\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Capability\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e600 A ac and dc current measurement\u003c\/li\u003e\n\u003cli\u003e2500 A ac current measurement with (optional) iFlex flexible current probe\u003c\/li\u003e\n\u003cli\u003e1000 V ac and dc voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue-rms voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eFrequency measurement to 500 Hz with body jaw and iFlex\u003c\/li\u003e\n\u003cli\u003eResistance measurement to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003e500 mV dc measurement range to interface with other accessories\u003c\/li\u003e\n\u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000V, CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent AC Range\u003c\/td\u003e\n\u003ctd\u003e600A with clamp jaws\u003cbr\u003e2500A with optional iFlex flexible current clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC Range\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage AC\/DC Range\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV DC Range\u003c\/td\u003e\n\u003ctd\u003e500mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOhms Range\u003c\/td\u003e\n\u003ctd\u003e60.00kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e5 to 500.0Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1μF to 1,000μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 375 FC TRMS AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003cli\u003eTL75 Test Leads\u003c\/li\u003e\n\u003cli\u003e2 x AA Alkaline Batteries\u003c\/li\u003e\n\u003cli\u003eCoated Instruction Card\u003c\/li\u003e\n\u003cli\u003eSafety Information Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_370_Series_FC_Spec.pdf?1825\" target=\"_blank\" title=\"Fluke 375FC Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 375FC Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 375FC True-RMS AC/DC Clamp Meter

Fluke 375FC True-RMS AC/DC Clamp Meter

$788.79 CAD

The Fluke 375 FC Wireless True-rms AC/DC Clamp Meter offers logging capabilities and measures up to 1000 V and 600 A, AC or DC. Performing welding parameters? Then this is the perfect meter for you! Overview Connect your meter to your smartphone with Fluke Connect Measurements Read measurements on your phone at a safe distance, wearing less PP...


More Info
{"id":1038703099947,"title":"Fluke 325 400A AC\/DC True-rms Clamp Meter","handle":"fluke-325-400a-ac-dc-true-rms-clamp-meter","description":"\u003cp\u003e\u003cstrong\u003eFluke 325 True RMS Clamp Meter offers big AC\/DC features in a small form factor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 325 Clamp Meter is the top of the 320 Series Clamp Meters. Designed to perform in the toughest environments and provide noise-free, reliable results, you can trust the 325 to help you confidently diagnose all kinds of electrical problems. It features True RMS measurements, optimized ergonomics, a large backlight display, and a rugged compact design to measure current up to 400 A in tight cable compartments. You can also use it to measure temperature, capacitance, AC\/DC current and frequency. Commercial and residential electricians use the 325 to verify the presence of load current, AC voltage, and continuity of circuits, switches, fuses and contacts. Frequency measurements allow checking of portable generators; dc current testing battery backups and solar storage equipment.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 325 comes with a two-year warranty and a soft carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRugged, reliable True-RMS clamp meter with dc current and frequency measurements\u003c\/li\u003e\n\u003cli\u003eMeasures AC and DC current to 400 A\u003c\/li\u003e\n\u003cli\u003eMeasures AC voltage and DC voltage to 600 V\u003c\/li\u003e\n\u003cli\u003eProvides True RMS AC voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eMeasures resistance to 40 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 500 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" width=\"25%\"\u003eAC current\u003c\/td\u003e\n\u003ctd width=\"25%\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e40.00 A \/ 400.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% ± 5 digits (45 Hz to 65 Hz)\u003cbr\u003e2.5% ± 5 digits (65 Hz to 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC current\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e40.00 A \/ 400.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω \/ 4000 Ω \/ 40.00 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤ 30 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e0 to 100.0 μF \/ 100μF to 1000 μF\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAC response\u003c\/td\u003e\n\u003ctd\u003eTrue-RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eData hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContact temperature\u003c\/td\u003e\n\u003ctd\u003e-10.0°C to 400.0°C (14.0°F to 752.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMin\/Max\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eH x W x D (mm)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e207 x 75 x 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax wire diameter\u003c\/td\u003e\n\u003ctd\u003e30 mm (600 MCM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e283 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCategory rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003cbr\u003eCAT IV 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eTwo-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eSoft case\u003c\/li\u003e\n\u003cli\u003eUser's manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_320_Series_Spec_6c76e86c-6677-488d-abd4-57337942f6d9.PDF?1819\" target=\"_blank\" title=\"Fluke 325 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 325 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-02-21T16:58:03-07:00","created_at":"2018-02-21T17:00:32-07:00","vendor":"Fluke","type":"Clamp Meters","tags":[],"price":57119,"price_min":57119,"price_max":57119,"available":true,"price_varies":false,"compare_at_price":42700,"compare_at_price_min":42700,"compare_at_price_max":42700,"compare_at_price_varies":false,"variants":[{"id":10708696301611,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-325","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 325 400A AC\/DC True-rms Clamp Meter","public_title":null,"options":["Default Title"],"price":57119,"weight":2268,"compare_at_price":42700,"inventory_management":"shopify","barcode":"095969623766","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke_325_1.jpg?v=1569858523","\/\/kingswayinstruments.com\/cdn\/shop\/products\/71Q-LoGsarL._SL1487.jpg?v=1569858523"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke_325_1.jpg?v=1569858523","options":["Title"],"media":[{"alt":null,"id":1417846882347,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke_325_1.jpg?v=1569858523"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke_325_1.jpg?v=1569858523","width":1024},{"alt":null,"id":1417846849579,"position":2,"preview_image":{"aspect_ratio":0.923,"height":1487,"width":1372,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/71Q-LoGsarL._SL1487.jpg?v=1569858523"},"aspect_ratio":0.923,"height":1487,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/71Q-LoGsarL._SL1487.jpg?v=1569858523","width":1372}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cstrong\u003eFluke 325 True RMS Clamp Meter offers big AC\/DC features in a small form factor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 325 Clamp Meter is the top of the 320 Series Clamp Meters. Designed to perform in the toughest environments and provide noise-free, reliable results, you can trust the 325 to help you confidently diagnose all kinds of electrical problems. It features True RMS measurements, optimized ergonomics, a large backlight display, and a rugged compact design to measure current up to 400 A in tight cable compartments. You can also use it to measure temperature, capacitance, AC\/DC current and frequency. Commercial and residential electricians use the 325 to verify the presence of load current, AC voltage, and continuity of circuits, switches, fuses and contacts. Frequency measurements allow checking of portable generators; dc current testing battery backups and solar storage equipment.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 325 comes with a two-year warranty and a soft carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRugged, reliable True-RMS clamp meter with dc current and frequency measurements\u003c\/li\u003e\n\u003cli\u003eMeasures AC and DC current to 400 A\u003c\/li\u003e\n\u003cli\u003eMeasures AC voltage and DC voltage to 600 V\u003c\/li\u003e\n\u003cli\u003eProvides True RMS AC voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eMeasures resistance to 40 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 500 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" width=\"25%\"\u003eAC current\u003c\/td\u003e\n\u003ctd width=\"25%\"\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e40.00 A \/ 400.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% ± 5 digits (45 Hz to 65 Hz)\u003cbr\u003e2.5% ± 5 digits (65 Hz to 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC current\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e40.00 A \/ 400.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC voltage\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω \/ 4000 Ω \/ 40.00 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e≤ 30 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e0 to 100.0 μF \/ 100μF to 1000 μF\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e5.0 Hz to 500.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAC response\u003c\/td\u003e\n\u003ctd\u003eTrue-RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eData hold\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eContact temperature\u003c\/td\u003e\n\u003ctd\u003e-10.0°C to 400.0°C (14.0°F to 752.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMin\/Max\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eSize\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eH x W x D (mm)\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e207 x 75 x 34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax wire diameter\u003c\/td\u003e\n\u003ctd\u003e30 mm (600 MCM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e283 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCategory rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 600 V\u003cbr\u003eCAT IV 300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eTwo-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eSoft case\u003c\/li\u003e\n\u003cli\u003eUser's manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_320_Series_Spec_6c76e86c-6677-488d-abd4-57337942f6d9.PDF?1819\" target=\"_blank\" title=\"Fluke 325 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 325 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 325 400A AC/DC True-rms Clamp Meter

Fluke 325 400A AC/DC True-rms Clamp Meter

$571.19 CAD

Fluke 325 True RMS Clamp Meter offers big AC/DC features in a small form factor The Fluke 325 Clamp Meter is the top of the 320 Series Clamp Meters. Designed to perform in the toughest environments and provide noise-free, reliable results, you can trust the 325 to help you confidently diagnose all kinds of electrical problems. It features True R...


More Info
{"id":7166874550462,"title":"Fluke 375 True-RMS AC\/DC Clamp Meter, No Fluke Connect","handle":"fluke-375-true-rms-ac-dc-clamp-meter-no-fluke-connect","description":"\u003cp\u003e\u003cspan\u003eThe Fluke 375 (Non-FC) True-rms AC\/DC Clamp Meter measures up to 1000 V and 600 A, AC or DC. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*This unit does not have FC Fluke Connect - See the Fluke 375FC for this model*\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with TPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eIntegrated VFD low pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V safety rating\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Capability\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e600 A ac and dc current measurement\u003c\/li\u003e\n\u003cli\u003e1000 V ac and dc voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue-rms voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eResistance measurement to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000V, CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent AC Range\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC Range\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage AC\/DC Range\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003c!-- split --\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 375 FC TRMS AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003cli\u003eTL75 Test Leads\u003c\/li\u003e\n\u003cli\u003e2 x AA Alkaline Batteries\u003c\/li\u003e\n\u003cli\u003eCoated Instruction Card\u003c\/li\u003e\n\u003cli\u003eSafety Information Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","published_at":"2022-02-23T08:18:02-07:00","created_at":"2022-02-23T08:18:03-07:00","vendor":"Fluke","type":"Clamp Meters","tags":[],"price":71500,"price_min":71500,"price_max":71500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41226828775614,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-375","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 375 True-RMS AC\/DC Clamp Meter, No Fluke Connect","public_title":null,"options":["Default Title"],"price":71500,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke375NonFC.jpg?v=1645629621"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke375NonFC.jpg?v=1645629621","options":["Title"],"media":[{"alt":null,"id":23123019464894,"position":1,"preview_image":{"aspect_ratio":1.0,"height":565,"width":565,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke375NonFC.jpg?v=1645629621"},"aspect_ratio":1.0,"height":565,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke375NonFC.jpg?v=1645629621","width":565}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Fluke 375 (Non-FC) True-rms AC\/DC Clamp Meter measures up to 1000 V and 600 A, AC or DC. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*This unit does not have FC Fluke Connect - See the Fluke 375FC for this model*\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with TPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eIntegrated VFD low pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V safety rating\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Capability\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e600 A ac and dc current measurement\u003c\/li\u003e\n\u003cli\u003e1000 V ac and dc voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue-rms voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eResistance measurement to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000V, CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent AC Range\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC Range\u003c\/td\u003e\n\u003ctd\u003e600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage AC\/DC Range\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003c!-- split --\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 375 FC TRMS AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003cli\u003eTL75 Test Leads\u003c\/li\u003e\n\u003cli\u003e2 x AA Alkaline Batteries\u003c\/li\u003e\n\u003cli\u003eCoated Instruction Card\u003c\/li\u003e\n\u003cli\u003eSafety Information Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e"}
Fluke 375 True-RMS AC/DC Clamp Meter, No Fluke Connect

Fluke 375 True-RMS AC/DC Clamp Meter, No Fluke Connect

$715.00 CAD

The Fluke 375 (Non-FC) True-rms AC/DC Clamp Meter measures up to 1000 V and 600 A, AC or DC.  *This unit does not have FC Fluke Connect - See the Fluke 375FC for this model* Overview Compatible with TPAK magnetic hanging strap Integrated VFD low pass filter for accurate motor drive measurements Proprietary inrush measurement technology to filt...


More Info
{"id":1072435003435,"title":"Fluke 376FC True-RMS AC\/DC Clamp Meter with iFlex","handle":"fluke-376-fc-true-rms-ac-dc-clamp-meter-with-iflex","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 376 FC Wireless True-rms AC\/DC Clamp Meter offers logging capabilities, includes the iFlex™ Flexible Current Probe, and measures up to  1000 V and 1000 A, AC or DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/PwWr4B3SbP8?rel=0\" frameborder=\"0\" allow=\"autoplay; encrypted-media\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConnect your meter to your smartphone with Fluke Connect Measurements\u003c\/li\u003e\n\u003cli\u003eRead measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks\u003c\/li\u003e\n\u003cli\u003eRecord results directly to your phone and the Cloud\u003c\/li\u003e\n\u003cli\u003eCapture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC\u003c\/li\u003e\n\u003cli\u003eCreate and share reports from the field via email, or converse in real-time with ShareLive™ video calls\u003c\/li\u003e\n\u003cli\u003eiFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)\u003c\/li\u003e\n\u003cli\u003eTPAK magnetic hanging strap (included)\u003c\/li\u003e\n\u003cli\u003eIntegrated VFD low pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V safety rating\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Capability\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1000 A ac and dc current measurement\u003c\/li\u003e\n\u003cli\u003e2500 A ac current measurement with iFlex flexible current probe\u003c\/li\u003e\n\u003cli\u003e1000 V ac and dc voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue-rms voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eFrequency measurement to 500 Hz with body jaw and iFlex\u003c\/li\u003e\n\u003cli\u003eResistance measurement to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003e500 mV dc measurement range to interface with other accessories\u003c\/li\u003e\n\u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000V, CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent AC Range\u003c\/td\u003e\n\u003ctd\u003e999.9A with clamp jaws\u003cbr\u003e2500A with iFlex flexible current clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC Range\u003c\/td\u003e\n\u003ctd\u003e999.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e1000V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV DC Range\u003c\/td\u003e\n\u003ctd\u003e500mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOhms Range\u003c\/td\u003e\n\u003ctd\u003e60.00kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e5 to 500.0Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1μF to 1,000μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 376FC Clamp Meter\u003c\/li\u003e\n\u003cli\u003e18-inch iFlex® Flexible Current Probe\u003c\/li\u003e\n\u003cli\u003eTPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eTL75 test leads\u003c\/li\u003e\n\u003cli\u003eTwo AA Alkaline batteries\u003c\/li\u003e\n\u003cli\u003eCoated instruction card\u003c\/li\u003e\n\u003cli\u003eSafety information sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_376FC_Spec.PDF?1287\" target=\"_blank\" title=\"Fluke 376FC Spec Sheet\" rel=\"noopener noreferrer\"\u003e Fluke 376FC Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-03-06T16:05:18-07:00","created_at":"2018-03-06T16:07:33-07:00","vendor":"Fluke","type":"Clamp Meters","tags":[],"price":89759,"price_min":89759,"price_max":89759,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11020060033067,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-376FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 376FC True-RMS AC\/DC Clamp Meter with iFlex","public_title":null,"options":["Default Title"],"price":89759,"weight":1361,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969798396","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/flu376fc-3.jpg?v=1520377655","\/\/kingswayinstruments.com\/cdn\/shop\/products\/51IgkXdntIL._SL1000.jpg?v=1520377656"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/flu376fc-3.jpg?v=1520377655","options":["Title"],"media":[{"alt":null,"id":1472790134827,"position":1,"preview_image":{"aspect_ratio":1.493,"height":1206,"width":1800,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/flu376fc-3.jpg?v=1520377655"},"aspect_ratio":1.493,"height":1206,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/flu376fc-3.jpg?v=1520377655","width":1800},{"alt":null,"id":1472790233131,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/51IgkXdntIL._SL1000.jpg?v=1520377656"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/51IgkXdntIL._SL1000.jpg?v=1520377656","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 376 FC Wireless True-rms AC\/DC Clamp Meter offers logging capabilities, includes the iFlex™ Flexible Current Probe, and measures up to  1000 V and 1000 A, AC or DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/PwWr4B3SbP8?rel=0\" frameborder=\"0\" allow=\"autoplay; encrypted-media\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConnect your meter to your smartphone with Fluke Connect Measurements\u003c\/li\u003e\n\u003cli\u003eRead measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks\u003c\/li\u003e\n\u003cli\u003eRecord results directly to your phone and the Cloud\u003c\/li\u003e\n\u003cli\u003eCapture intermittent faults while performing other tasks using the logging capabilities of the Fluke 376 FC\u003c\/li\u003e\n\u003cli\u003eCreate and share reports from the field via email, or converse in real-time with ShareLive™ video calls\u003c\/li\u003e\n\u003cli\u003eiFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)\u003c\/li\u003e\n\u003cli\u003eTPAK magnetic hanging strap (included)\u003c\/li\u003e\n\u003cli\u003eIntegrated VFD low pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V safety rating\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Capability\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1000 A ac and dc current measurement\u003c\/li\u003e\n\u003cli\u003e2500 A ac current measurement with iFlex flexible current probe\u003c\/li\u003e\n\u003cli\u003e1000 V ac and dc voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue-rms voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eFrequency measurement to 500 Hz with body jaw and iFlex\u003c\/li\u003e\n\u003cli\u003eResistance measurement to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003e500 mV dc measurement range to interface with other accessories\u003c\/li\u003e\n\u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000V, CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent AC Range\u003c\/td\u003e\n\u003ctd\u003e999.9A with clamp jaws\u003cbr\u003e2500A with iFlex flexible current clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC Range\u003c\/td\u003e\n\u003ctd\u003e999.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e1000V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV DC Range\u003c\/td\u003e\n\u003ctd\u003e500mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOhms Range\u003c\/td\u003e\n\u003ctd\u003e60.00kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e5 to 500.0Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1μF to 1,000μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 376FC Clamp Meter\u003c\/li\u003e\n\u003cli\u003e18-inch iFlex® Flexible Current Probe\u003c\/li\u003e\n\u003cli\u003eTPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eTL75 test leads\u003c\/li\u003e\n\u003cli\u003eTwo AA Alkaline batteries\u003c\/li\u003e\n\u003cli\u003eCoated instruction card\u003c\/li\u003e\n\u003cli\u003eSafety information sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_376FC_Spec.PDF?1287\" target=\"_blank\" title=\"Fluke 376FC Spec Sheet\" rel=\"noopener noreferrer\"\u003e Fluke 376FC Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 376FC True-RMS AC/DC Clamp Meter with iFlex

Fluke 376FC True-RMS AC/DC Clamp Meter with iFlex

$897.59 CAD

The Fluke 376 FC Wireless True-rms AC/DC Clamp Meter offers logging capabilities, includes the iFlex™ Flexible Current Probe, and measures up to  1000 V and 1000 A, AC or DC. Overview Connect your meter to your smartphone with Fluke Connect Measurements Read measurements on your phone at a safe distance, wearing less PPE while your meter tak...


More Info
{"id":6624368820414,"title":"Fluke 377FC Non-Contact True RMS AC\/DC Clamp Meter","handle":"fluke-377fc-non-contact-true-rms-ac-dc-clamp-meter","description":"\u003cp\u003e\u003cspan\u003eThe Fluke 377 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/Fykn84SHes0\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure voltage and current with your clamp jaw\u003c\/li\u003e\n\u003cli\u003eFaster, safer testing all without touching a live wire using FieldSense™ technology\u003c\/li\u003e\n\u003cli\u003eComplete three-phase voltage and current tests in three quick steps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage and current measurements with FieldSense™ technology\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo more hand-written notes or complicated math.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete 3-phase voltage and current tests in three easy steps\u003c\/li\u003e\n\u003cli\u003eFull set of phase-to-ground and phase-to-phase values calculated\u003c\/li\u003e\n\u003cli\u003eDisplayed on your smart phone and saved to the cloud via Fluke Connect software\u003c\/li\u003e\n\u003cli\u003ePhase rotation calculated and shown on the Fluke Connect software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasure extremely high current with iFlex™ probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy to see, easy to use with included tools\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYour job will get easier when you use this clamp meter:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe display turns green when a stable FieldSense measurement is detected\u003c\/li\u003e\n\u003cli\u003eVisual Continuity provides a bright green screen for easy detection of continuity in noisy work areas\u003c\/li\u003e\n\u003cli\u003eThe magnetic hanging kit, with 9\" (23 cm) hanging strap, lets you hang your clamp wherever you need: to a steel cabinet door; around a pipe; on a nail or screw head\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC - Jaw\u003c\/td\u003e\n\u003ctd\u003eRange: 999.9 A\u003cbr\u003eResolution: 0.1 A\u003cbr\u003eAccuracy: 2% ±5 digits (10 to 100 Hz); 2.5% ±5 digits (100 to 500 Hz)\u003cbr\u003eCrest factor (50\/60 Hz): 3 at 500 A; 2.5 at 600 A; 1.42 at 1000 A; Add 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC - Flexible Current Probe\u003c\/td\u003e\n\u003ctd\u003eRange: 2500 A\u003cbr\u003eResolution: 1 A (≤2500 A) 0.1 A (≤999.9 A)\u003cbr\u003eAccuracy: 3% ±5 digits (5 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003ctd\u003eRange: 999.9 A\u003cbr\u003eResolution: 0.1 A\u003cbr\u003eAccuracy: 2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC - FieldSense\u003c\/td\u003e\n\u003ctd\u003eRange: 1000 V\u003cbr\u003eResolution: 1 V (≤1000 V)\u003cbr\u003eAccuracy: ≤4\/0 AWG - 3% ±5 digits (45 to 66 Hz); ≥4\/0 AWG - 5% ±5 digits (45 to 66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC - Test Leads\u003c\/td\u003e\n\u003ctd\u003eRange: 600.0 V, 1000 V\u003cbr\u003eResolution: 0.1 V (≤600.0 V); 1 V (≤1000 V)\u003cbr\u003eAccuracy: 1% ±5 digits (20 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003ctd\u003eRange: 600 V, 1000 V\u003cbr\u003eResolution: 0.1 V (≤600 V); 1 V (≤1000 V)\u003cbr\u003eAccuracy: 1% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV DC\u003c\/td\u003e\n\u003ctd\u003eRange: 500 mV\u003cbr\u003eResolution: 0.1 mV\u003cbr\u003eAccuracy: 1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAmps Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw\u003c\/td\u003e\n\u003ctd\u003eRange: 5 to 500 Hz\u003cbr\u003eResolution: 0.1 Hz\u003cbr\u003eAccuracy: 0.5% ±5 digits\u003cbr\u003eTrigger level: 5 to 10 Hz, ≥10 A; 10 to 100 Hz, ≥5 A; 100 to 500 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe\u003c\/td\u003e\n\u003ctd\u003eRange: 5 to 500 Hz\u003cbr\u003eResolution: 0.1 Hz\u003cbr\u003eAccuracy: 0.5% ±5 digits\u003cbr\u003eTrigger level: 5 to 20 Hz, ≥25 A; 20 to 100 Hz, ≥20 A; 100 to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOther Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eRange: 60 kΩ, 6000 Ω, 600 Ω\u003cbr\u003eResolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 10 Ω (≤60 kΩ)\u003cbr\u003eAccuracy: 1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003eRange: 1000 μF\u003cbr\u003eResolution: 0.1 μF (≤100 μF), 1 F (≤1000 μF)\u003cbr\u003eAccuracy: 1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Maximum Voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V (between any terminal and earth ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eType: 2 x AA IEC LR6 alkaline\u003cbr\u003elife: 200 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDual readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd\u003e20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eOperating: 14 to 122°F (-10 to 50°C)\u003cbr\u003eStorage: -40 to 140°F (-40 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity (Without Condensation)\u003c\/td\u003e\n\u003ctd\u003eNon condensing (\u0026lt;50°F [\u0026lt;10°C])\u003cbr\u003e≤90% RH (50 to 86°F [10 to 30°C])\u003cbr\u003e≤75% RH (86 to 104°F [30 to 40°C])\u003cbr\u003e≤45% RH (104 to 122°F [40 to 50°C])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficients\u003c\/td\u003e\n\u003ctd\u003eAdd 0.1 x specified accuracy for each degree C \u0026gt;28°C or \u0026lt;18°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIEC 60529: IP30 (jaw closed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitute\u003c\/td\u003e\n\u003ctd\u003eOperating: 6561.68' (2000 m)\u003cbr\u003eStorage: 39,370.1' (12,000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\n\u003ctd\u003eUSA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eGeneral: IEC 61010-1: Pollution degree 2\u003cbr\u003eMeasurement: IEC 61010-2-032: CAT III 1000 V\/CAT IV 600 V; IEC 61010-2-033: CAT III 1000 V\/CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWireless Radio\u003c\/td\u003e\n\u003ctd\u003eRadio frequency certification: FCC ID: T68-FBLE IC:6627A-FBLE\u003cbr\u003eFrequency range: 2405 to 2480 MHz\u003cbr\u003eOutput power: \u0026lt;100 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.78 x 3.38 x 1.85\" (274 x 86 x 47 mm)\u003cbr\u003eJaw opening: 1.34\" (34 mm)\u003cbr\u003eFlexible current probe diameter: 0.29\" (7.5 mm)\u003cbr\u003eFlexible current probe cable length: 5.9' (1.8 m)\u003cbr\u003eRogowski coil length: 17.71\" (450 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs (463 g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 377 FC Non-Contact Voltage True-RMS AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003eTL224 Test Leads\u003c\/li\u003e\n\u003cli\u003eTP175 TwistGuard™ Test Probes\u003c\/li\u003e\n\u003cli\u003eAC285 black grounding clip (1 only)\u003c\/li\u003e\n\u003cli\u003ei2500-18 iFlex® Flexible Current Probes 18 inch (48 cm)\u003c\/li\u003e\n\u003cli\u003eTPAK ToolPak™ Magnetic Meter Hanger\u003c\/li\u003e\n\u003cli\u003ePremium carrying case\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003ca title=\"Fluke 377FC Non-Contact True RMS AC\/DC Clamp Meter\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_377-378_Clamp_Meter_Spec_Sheet.pdf?v=1618499642\" target=\"_blank\"\u003eFluke 377FC Non-Contact True RMS AC\/DC Clamp Meter) Spec Sheet\u003c\/a\u003e\u003c!-- split --\u003e","published_at":"2021-04-15T09:16:14-06:00","created_at":"2021-04-15T09:16:13-06:00","vendor":"Fluke","type":"Clamp Meters","tags":[],"price":106079,"price_min":106079,"price_max":106079,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39546910572734,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-377FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 377FC Non-Contact True RMS AC\/DC Clamp Meter","public_title":null,"options":["Default Title"],"price":106079,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969916608","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377.jpg?v=1620740376","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377Pic2.jpg?v=1620740415"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377.jpg?v=1620740376","options":["Title"],"media":[{"alt":null,"id":20844763644094,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377.jpg?v=1620740376"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377.jpg?v=1620740376","width":1000},{"alt":null,"id":20844766855358,"position":2,"preview_image":{"aspect_ratio":0.714,"height":1500,"width":1071,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377Pic2.jpg?v=1620740415"},"aspect_ratio":0.714,"height":1500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377Pic2.jpg?v=1620740415","width":1071}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Fluke 377 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e \u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/Fykn84SHes0\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure voltage and current with your clamp jaw\u003c\/li\u003e\n\u003cli\u003eFaster, safer testing all without touching a live wire using FieldSense™ technology\u003c\/li\u003e\n\u003cli\u003eComplete three-phase voltage and current tests in three quick steps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage and current measurements with FieldSense™ technology\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo more hand-written notes or complicated math.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete 3-phase voltage and current tests in three easy steps\u003c\/li\u003e\n\u003cli\u003eFull set of phase-to-ground and phase-to-phase values calculated\u003c\/li\u003e\n\u003cli\u003eDisplayed on your smart phone and saved to the cloud via Fluke Connect software\u003c\/li\u003e\n\u003cli\u003ePhase rotation calculated and shown on the Fluke Connect software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasure extremely high current with iFlex™ probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy to see, easy to use with included tools\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYour job will get easier when you use this clamp meter:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe display turns green when a stable FieldSense measurement is detected\u003c\/li\u003e\n\u003cli\u003eVisual Continuity provides a bright green screen for easy detection of continuity in noisy work areas\u003c\/li\u003e\n\u003cli\u003eThe magnetic hanging kit, with 9\" (23 cm) hanging strap, lets you hang your clamp wherever you need: to a steel cabinet door; around a pipe; on a nail or screw head\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC - Jaw\u003c\/td\u003e\n\u003ctd\u003eRange: 999.9 A\u003cbr\u003eResolution: 0.1 A\u003cbr\u003eAccuracy: 2% ±5 digits (10 to 100 Hz); 2.5% ±5 digits (100 to 500 Hz)\u003cbr\u003eCrest factor (50\/60 Hz): 3 at 500 A; 2.5 at 600 A; 1.42 at 1000 A; Add 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC - Flexible Current Probe\u003c\/td\u003e\n\u003ctd\u003eRange: 2500 A\u003cbr\u003eResolution: 1 A (≤2500 A) 0.1 A (≤999.9 A)\u003cbr\u003eAccuracy: 3% ±5 digits (5 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003ctd\u003eRange: 999.9 A\u003cbr\u003eResolution: 0.1 A\u003cbr\u003eAccuracy: 2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC - FieldSense\u003c\/td\u003e\n\u003ctd\u003eRange: 1000 V\u003cbr\u003eResolution: 1 V (≤1000 V)\u003cbr\u003eAccuracy: ≤4\/0 AWG - 3% ±5 digits (45 to 66 Hz); ≥4\/0 AWG - 5% ±5 digits (45 to 66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC - Test Leads\u003c\/td\u003e\n\u003ctd\u003eRange: 600.0 V, 1000 V\u003cbr\u003eResolution: 0.1 V (≤600.0 V); 1 V (≤1000 V)\u003cbr\u003eAccuracy: 1% ±5 digits (20 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC\u003c\/td\u003e\n\u003ctd\u003eRange: 600 V, 1000 V\u003cbr\u003eResolution: 0.1 V (≤600 V); 1 V (≤1000 V)\u003cbr\u003eAccuracy: 1% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV DC\u003c\/td\u003e\n\u003ctd\u003eRange: 500 mV\u003cbr\u003eResolution: 0.1 mV\u003cbr\u003eAccuracy: 1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAmps Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw\u003c\/td\u003e\n\u003ctd\u003eRange: 5 to 500 Hz\u003cbr\u003eResolution: 0.1 Hz\u003cbr\u003eAccuracy: 0.5% ±5 digits\u003cbr\u003eTrigger level: 5 to 10 Hz, ≥10 A; 10 to 100 Hz, ≥5 A; 100 to 500 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe\u003c\/td\u003e\n\u003ctd\u003eRange: 5 to 500 Hz\u003cbr\u003eResolution: 0.1 Hz\u003cbr\u003eAccuracy: 0.5% ±5 digits\u003cbr\u003eTrigger level: 5 to 20 Hz, ≥25 A; 20 to 100 Hz, ≥20 A; 100 to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOther Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eRange: 60 kΩ, 6000 Ω, 600 Ω\u003cbr\u003eResolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 10 Ω (≤60 kΩ)\u003cbr\u003eAccuracy: 1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003eRange: 1000 μF\u003cbr\u003eResolution: 0.1 μF (≤100 μF), 1 F (≤1000 μF)\u003cbr\u003eAccuracy: 1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral Maximum Voltage\u003c\/td\u003e\n\u003ctd\u003e1000 V (between any terminal and earth ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eType: 2 x AA IEC LR6 alkaline\u003cbr\u003elife: 200 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDual readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Power Off\u003c\/td\u003e\n\u003ctd\u003e20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eOperating: 14 to 122°F (-10 to 50°C)\u003cbr\u003eStorage: -40 to 140°F (-40 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity (Without Condensation)\u003c\/td\u003e\n\u003ctd\u003eNon condensing (\u0026lt;50°F [\u0026lt;10°C])\u003cbr\u003e≤90% RH (50 to 86°F [10 to 30°C])\u003cbr\u003e≤75% RH (86 to 104°F [30 to 40°C])\u003cbr\u003e≤45% RH (104 to 122°F [40 to 50°C])\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficients\u003c\/td\u003e\n\u003ctd\u003eAdd 0.1 x specified accuracy for each degree C \u0026gt;28°C or \u0026lt;18°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIEC 60529: IP30 (jaw closed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitute\u003c\/td\u003e\n\u003ctd\u003eOperating: 6561.68' (2000 m)\u003cbr\u003eStorage: 39,370.1' (12,000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Compatibility (EMC)\u003c\/td\u003e\n\u003ctd\u003eUSA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eGeneral: IEC 61010-1: Pollution degree 2\u003cbr\u003eMeasurement: IEC 61010-2-032: CAT III 1000 V\/CAT IV 600 V; IEC 61010-2-033: CAT III 1000 V\/CAT IV 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWireless Radio\u003c\/td\u003e\n\u003ctd\u003eRadio frequency certification: FCC ID: T68-FBLE IC:6627A-FBLE\u003cbr\u003eFrequency range: 2405 to 2480 MHz\u003cbr\u003eOutput power: \u0026lt;100 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.78 x 3.38 x 1.85\" (274 x 86 x 47 mm)\u003cbr\u003eJaw opening: 1.34\" (34 mm)\u003cbr\u003eFlexible current probe diameter: 0.29\" (7.5 mm)\u003cbr\u003eFlexible current probe cable length: 5.9' (1.8 m)\u003cbr\u003eRogowski coil length: 17.71\" (450 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 lbs (463 g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 377 FC Non-Contact Voltage True-RMS AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003eTL224 Test Leads\u003c\/li\u003e\n\u003cli\u003eTP175 TwistGuard™ Test Probes\u003c\/li\u003e\n\u003cli\u003eAC285 black grounding clip (1 only)\u003c\/li\u003e\n\u003cli\u003ei2500-18 iFlex® Flexible Current Probes 18 inch (48 cm)\u003c\/li\u003e\n\u003cli\u003eTPAK ToolPak™ Magnetic Meter Hanger\u003c\/li\u003e\n\u003cli\u003ePremium carrying case\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003ca title=\"Fluke 377FC Non-Contact True RMS AC\/DC Clamp Meter\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_377-378_Clamp_Meter_Spec_Sheet.pdf?v=1618499642\" target=\"_blank\"\u003eFluke 377FC Non-Contact True RMS AC\/DC Clamp Meter) Spec Sheet\u003c\/a\u003e\u003c!-- split --\u003e"}
Fluke 377FC Non-Contact True RMS AC/DC Clamp Meter

Fluke 377FC Non-Contact True RMS AC/DC Clamp Meter

$1,060.79 CAD

The Fluke 377 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage a...


More Info
Flir CM85-2 True RMS Power Clamp Meter

Clamp Meters

$675.00 CAD
{"id":7692134023358,"title":"Flir CM85-2 True RMS Power Clamp Meter","handle":"flir-cm85-2-true-rms-power-clamp-meter","description":"\u003cp\u003e\u003cspan\u003eThe FLIR CM85-2 is an industrial power clamp meter with advanced power analysis and variable frequency drive (VFD) filtering functions required by electrical troubleshooters for full-scale equipment. Accurately analyze voltage in complex machinery by including harmonics, inrush, current, and phase rotation testing with a wide AC\/DC voltage range and base accuracy of +\/-1%. Stream live data in real time from the CM85-2 to your mobile device over Bluetooth®. Using the METERLiNK® app, you can compare log files, create alarm thresholds, visualize trends, and create reports to share with team members.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul class=\"FeatureShowcase-list\"\u003e\n\u003cli class=\"FeatureShowcase-listItem\"\u003e\n\u003cstrong\u003e\u003cspan class=\"subtitle-h6\"\u003eSUPERIOR POWER ANALYSIS\u003c\/span\u003e\u003c\/strong\u003e\n\u003cp\u003eVFD mode increases accuracy when working on VFD-controlled equipment. Conduct multiple conductor measurements with True RMS AC Current up to 1000 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"FeatureShowcase-listItem\"\u003e\n\u003cstrong\u003e\u003cspan class=\"subtitle-h6\"\u003ePURPOSE BUILT FOR INSPECTIONS\u003c\/span\u003e\u003c\/strong\u003e\n\u003cp\u003eDual LED lights eliminate the need to carry additional tools, and an ergonomic industrial design offers ease of use and operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"FeatureShowcase-listItem\"\u003e\n\u003cstrong\u003e\u003cspan class=\"subtitle-h6\"\u003eINSPECT AT A SAFE DISTANCE\u003c\/span\u003e\u003c\/strong\u003e\n\u003cp\u003eStream live readings in real time from the meter to your mobile device over Bluetooth using the METERLiNK app from a distance up to 10 m (32 ft).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"Specifications-list\"\u003e\n\u003ch6 class=\"Specifications-header\"\u003eOVERVIEW\u003c\/h6\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003e\n\u003ch6 class=\"Specifications-header\"\u003eMEASUREMENT \u0026amp; ANALYSIS\u003c\/h6\u003e\n\u003c\/dt\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eAC Current\u003c\/dt\u003e\n\u003cdd\u003e99.99 A, 50-60 Hz ± (2% + 5 digits); \u0026gt;60–400 Hz ± (2.5% + 5 digits)\u003cbr\u003e999.9 A, 50-60 Hz ± (2% + 5 digits); \u0026gt;60–400 Hz ± (2.5% + 5 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eAC Voltage\u003c\/dt\u003e\n\u003cdd\u003e99.99 V, 50–500 Hz ±(1.0% + 5 digits)\u003cbr\u003e999.9 V, 50–500 Hz ±(1.0% + 5 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eCapacitance\u003c\/dt\u003e\n\u003cdd\u003e3.999 μF, ±(1.9% + 8 digits)\u003cbr\u003e39.99 μF, ±(1.9% + 8 digits)\u003cbr\u003e399.9 μF, ±(1.9% + 8 digits)\u003cbr\u003e3.999 mF, ±(1.9% + 8 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eContinuity\u003c\/dt\u003e\n\u003cdd\u003e999.9 Ω, ±(1.0% + 5 digits)\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eDC Current\u003c\/dt\u003e\n\u003cdd\u003e99.99 A, ±(2% + 0.5 A)\u003cbr\u003e999.9 A, ±(2% + 5 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eDC Voltage\u003c\/dt\u003e\n\u003cdd\u003e99.99 V, ±(0.7% + 2 digits)\u003cbr\u003e999.9 V, ±(0.7% + 2 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eDiode\u003c\/dt\u003e\n\u003cdd\u003e0.40 to 0.80 V, ±0.1 V\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eFrequency\u003c\/dt\u003e\n\u003cdd\u003e20.00 to 99.99 Hz, ±(0.5% + 3 digits)\u003cbr\u003e20.0 to 999.9 Hz, ±(0.5% + 3 digits)\u003cbr\u003e0.020 to 9.999 kHz, ±(0.5% + 3 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eHarmonics\u003c\/dt\u003e\n\u003cdd\u003eTotal harmonic distortion ACA\/ACV: 99.9%, ±(3.0% + 10 digits)\u003cbr\u003eHarmonic distortion: H01–H12 99.9%, ±(5% + 10 digits)\u003cbr\u003eHarmonic distortion: H13–H25 99.9%, ±(10% + 10 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eInrush Current\u003c\/dt\u003e\n\u003cdd\u003eACA:\u003cbr\u003e99.99 A, ±(3% + 0.3 A)\u003cbr\u003e999.9 A, ±(3% + 5 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eMeasuring Rate\u003c\/dt\u003e\n\u003cdd\u003e3 times per second\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003ePeak Hold\u003c\/dt\u003e\n\u003cdd\u003eACV:\u003cbr\u003e140.0 V, ±(3.0% + 15 digits)\u003cbr\u003e1400 V, ±(3.0% + 15 digits)\u003cbr\u003e\u003cbr\u003eACA:\u003cbr\u003e140.0 A, ±(3.5% + 15 digits)\u003cbr\u003e1400 A, ±(3.5% + 15 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003ePower Factor\u003c\/dt\u003e\n\u003cdd\u003e-1.00 to 0.00 to +1.00, ±3° ±1 digit\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eRecording\u003c\/dt\u003e\n\u003cdd\u003eData recording available via METERLiNK App\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eResistance\u003c\/dt\u003e\n\u003cdd\u003e999.9 Ω, ±(1.0% + 5 digits)\u003cbr\u003e9.999 kΩ, ±(1.0% + 3 digits)\u003cbr\u003e99.99 kΩ, ±(1.0% + 3 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eVFD\u003c\/dt\u003e\n\u003cdd\u003eACV:\u003cbr\u003e99.99 V, 50–60 Hz ±(1% + 5 digits)\u003cbr\u003e999.9 V, 50–60 Hz ±(1% + 5 digits)\u003cbr\u003e\u003cbr\u003eACA:\u003cbr\u003e99.99 A, 50–60 Hz ±(2% + 5 digits)\u003cbr\u003e999.9 A, 50–60 Hz ±(2% + 5 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eWatts\u003c\/dt\u003e\n\u003cdd\u003eDC:\u003cbr\u003e9.999 kW (10 V, 5 A min), ±(3% + 0.05 kW)\u003cbr\u003e99.99 kW (10 V, 5 A min), ±(3% + 0.5 kW)\u003cbr\u003e999.9 kW (10 V, 5 A min), ±(3% + 10 digits)\u003cbr\u003e\u003cbr\u003eAC:\u003cbr\u003e9.999 kW (10 V, 5 A min), ±(3% + 10 digits)\u003cbr\u003e99.99 kW (10 V, 5 A min), ±(3% + 10 digits)\u003cbr\u003e999.9 kW (10 V, 5 A min), ±(3% + 10 digits)\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Power Clamp\u003c\/li\u003e\n\u003cli\u003eSet of CAT IV-600V Test Leads\u003c\/li\u003e\n\u003cli\u003e6 x LR03 Alkaline Batteries\u003c\/li\u003e\n\u003cli\u003eQuick Start Guide\u003c\/li\u003e\n\u003cli\u003eWarranty Card\u003c\/li\u003e\n\u003cli\u003eLimited Lifetime Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e","published_at":"2023-07-17T08:50:19-06:00","created_at":"2023-07-17T08:50:19-06:00","vendor":"Flir","type":"Clamp Meters","tags":[],"price":67500,"price_min":67500,"price_max":67500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":42902044180670,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLIR-CM85-2","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Flir CM85-2 True RMS Power Clamp Meter","public_title":null,"options":["Default Title"],"price":67500,"weight":1361,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/files\/FlirCM85-2.jpg?v=1689605567"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/FlirCM85-2.jpg?v=1689605567","options":["Title"],"media":[{"alt":null,"id":26122284204222,"position":1,"preview_image":{"aspect_ratio":0.54,"height":500,"width":270,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/FlirCM85-2.jpg?v=1689605567"},"aspect_ratio":0.54,"height":500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/FlirCM85-2.jpg?v=1689605567","width":270}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe FLIR CM85-2 is an industrial power clamp meter with advanced power analysis and variable frequency drive (VFD) filtering functions required by electrical troubleshooters for full-scale equipment. Accurately analyze voltage in complex machinery by including harmonics, inrush, current, and phase rotation testing with a wide AC\/DC voltage range and base accuracy of +\/-1%. Stream live data in real time from the CM85-2 to your mobile device over Bluetooth®. Using the METERLiNK® app, you can compare log files, create alarm thresholds, visualize trends, and create reports to share with team members.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul class=\"FeatureShowcase-list\"\u003e\n\u003cli class=\"FeatureShowcase-listItem\"\u003e\n\u003cstrong\u003e\u003cspan class=\"subtitle-h6\"\u003eSUPERIOR POWER ANALYSIS\u003c\/span\u003e\u003c\/strong\u003e\n\u003cp\u003eVFD mode increases accuracy when working on VFD-controlled equipment. Conduct multiple conductor measurements with True RMS AC Current up to 1000 Amps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"FeatureShowcase-listItem\"\u003e\n\u003cstrong\u003e\u003cspan class=\"subtitle-h6\"\u003ePURPOSE BUILT FOR INSPECTIONS\u003c\/span\u003e\u003c\/strong\u003e\n\u003cp\u003eDual LED lights eliminate the need to carry additional tools, and an ergonomic industrial design offers ease of use and operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"FeatureShowcase-listItem\"\u003e\n\u003cstrong\u003e\u003cspan class=\"subtitle-h6\"\u003eINSPECT AT A SAFE DISTANCE\u003c\/span\u003e\u003c\/strong\u003e\n\u003cp\u003eStream live readings in real time from the meter to your mobile device over Bluetooth using the METERLiNK app from a distance up to 10 m (32 ft).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"Specifications-list\"\u003e\n\u003ch6 class=\"Specifications-header\"\u003eOVERVIEW\u003c\/h6\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003e\n\u003ch6 class=\"Specifications-header\"\u003eMEASUREMENT \u0026amp; ANALYSIS\u003c\/h6\u003e\n\u003c\/dt\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eAC Current\u003c\/dt\u003e\n\u003cdd\u003e99.99 A, 50-60 Hz ± (2% + 5 digits); \u0026gt;60–400 Hz ± (2.5% + 5 digits)\u003cbr\u003e999.9 A, 50-60 Hz ± (2% + 5 digits); \u0026gt;60–400 Hz ± (2.5% + 5 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eAC Voltage\u003c\/dt\u003e\n\u003cdd\u003e99.99 V, 50–500 Hz ±(1.0% + 5 digits)\u003cbr\u003e999.9 V, 50–500 Hz ±(1.0% + 5 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eCapacitance\u003c\/dt\u003e\n\u003cdd\u003e3.999 μF, ±(1.9% + 8 digits)\u003cbr\u003e39.99 μF, ±(1.9% + 8 digits)\u003cbr\u003e399.9 μF, ±(1.9% + 8 digits)\u003cbr\u003e3.999 mF, ±(1.9% + 8 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eContinuity\u003c\/dt\u003e\n\u003cdd\u003e999.9 Ω, ±(1.0% + 5 digits)\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eDC Current\u003c\/dt\u003e\n\u003cdd\u003e99.99 A, ±(2% + 0.5 A)\u003cbr\u003e999.9 A, ±(2% + 5 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eDC Voltage\u003c\/dt\u003e\n\u003cdd\u003e99.99 V, ±(0.7% + 2 digits)\u003cbr\u003e999.9 V, ±(0.7% + 2 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eDiode\u003c\/dt\u003e\n\u003cdd\u003e0.40 to 0.80 V, ±0.1 V\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eFrequency\u003c\/dt\u003e\n\u003cdd\u003e20.00 to 99.99 Hz, ±(0.5% + 3 digits)\u003cbr\u003e20.0 to 999.9 Hz, ±(0.5% + 3 digits)\u003cbr\u003e0.020 to 9.999 kHz, ±(0.5% + 3 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eHarmonics\u003c\/dt\u003e\n\u003cdd\u003eTotal harmonic distortion ACA\/ACV: 99.9%, ±(3.0% + 10 digits)\u003cbr\u003eHarmonic distortion: H01–H12 99.9%, ±(5% + 10 digits)\u003cbr\u003eHarmonic distortion: H13–H25 99.9%, ±(10% + 10 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eInrush Current\u003c\/dt\u003e\n\u003cdd\u003eACA:\u003cbr\u003e99.99 A, ±(3% + 0.3 A)\u003cbr\u003e999.9 A, ±(3% + 5 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eMeasuring Rate\u003c\/dt\u003e\n\u003cdd\u003e3 times per second\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003ePeak Hold\u003c\/dt\u003e\n\u003cdd\u003eACV:\u003cbr\u003e140.0 V, ±(3.0% + 15 digits)\u003cbr\u003e1400 V, ±(3.0% + 15 digits)\u003cbr\u003e\u003cbr\u003eACA:\u003cbr\u003e140.0 A, ±(3.5% + 15 digits)\u003cbr\u003e1400 A, ±(3.5% + 15 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003ePower Factor\u003c\/dt\u003e\n\u003cdd\u003e-1.00 to 0.00 to +1.00, ±3° ±1 digit\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eRecording\u003c\/dt\u003e\n\u003cdd\u003eData recording available via METERLiNK App\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eResistance\u003c\/dt\u003e\n\u003cdd\u003e999.9 Ω, ±(1.0% + 5 digits)\u003cbr\u003e9.999 kΩ, ±(1.0% + 3 digits)\u003cbr\u003e99.99 kΩ, ±(1.0% + 3 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eVFD\u003c\/dt\u003e\n\u003cdd\u003eACV:\u003cbr\u003e99.99 V, 50–60 Hz ±(1% + 5 digits)\u003cbr\u003e999.9 V, 50–60 Hz ±(1% + 5 digits)\u003cbr\u003e\u003cbr\u003eACA:\u003cbr\u003e99.99 A, 50–60 Hz ±(2% + 5 digits)\u003cbr\u003e999.9 A, 50–60 Hz ±(2% + 5 digits)\u003cbr\u003e\n\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdl class=\"Spec-list\"\u003e\n\u003cdt\u003eWatts\u003c\/dt\u003e\n\u003cdd\u003eDC:\u003cbr\u003e9.999 kW (10 V, 5 A min), ±(3% + 0.05 kW)\u003cbr\u003e99.99 kW (10 V, 5 A min), ±(3% + 0.5 kW)\u003cbr\u003e999.9 kW (10 V, 5 A min), ±(3% + 10 digits)\u003cbr\u003e\u003cbr\u003eAC:\u003cbr\u003e9.999 kW (10 V, 5 A min), ±(3% + 10 digits)\u003cbr\u003e99.99 kW (10 V, 5 A min), ±(3% + 10 digits)\u003cbr\u003e999.9 kW (10 V, 5 A min), ±(3% + 10 digits)\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Power Clamp\u003c\/li\u003e\n\u003cli\u003eSet of CAT IV-600V Test Leads\u003c\/li\u003e\n\u003cli\u003e6 x LR03 Alkaline Batteries\u003c\/li\u003e\n\u003cli\u003eQuick Start Guide\u003c\/li\u003e\n\u003cli\u003eWarranty Card\u003c\/li\u003e\n\u003cli\u003eLimited Lifetime Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e"}
Flir CM85-2 True RMS Power Clamp Meter

Flir CM85-2 True RMS Power Clamp Meter

$675.00 CAD

The FLIR CM85-2 is an industrial power clamp meter with advanced power analysis and variable frequency drive (VFD) filtering functions required by electrical troubleshooters for full-scale equipment. Accurately analyze voltage in complex machinery by including harmonics, inrush, current, and phase rotation testing with a wide AC/DC voltage range...


More Info
Sold Out
Fluke 376 True-RMS AC/DC Clamp Meter, No Fluke Connect
{"id":7188852310206,"title":"Fluke 376 True-RMS AC\/DC Clamp Meter, No Fluke Connect","handle":"fluke-376-true-rms-ac-dc-clamp-meter-no-fluke-connect","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 376 True-rms AC\/DC Clamp Meter includes the iFlex™ Flexible Current Probe and measures up to  1000 V and 1000 A, AC or DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*This unit is no longer available - See the Fluke 376FC replacement*\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eiFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)\u003c\/li\u003e\n\u003cli\u003eTPAK magnetic hanging strap (included)\u003c\/li\u003e\n\u003cli\u003eIntegrated VFD low pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V safety rating\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Capability\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1000 A ac and dc current measurement\u003c\/li\u003e\n\u003cli\u003e2500 A ac current measurement with iFlex flexible current probe\u003c\/li\u003e\n\u003cli\u003e1000 V ac and dc voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue-rms voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eFrequency measurement to 500 Hz with body jaw and iFlex\u003c\/li\u003e\n\u003cli\u003eResistance measurement to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003e500 mV dc measurement range to interface with other accessories\u003c\/li\u003e\n\u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000V, CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent AC Range\u003c\/td\u003e\n\u003ctd\u003e999.9A with clamp jaws\u003cbr\u003e2500A with iFlex flexible current clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC Range\u003c\/td\u003e\n\u003ctd\u003e999.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e1000V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV DC Range\u003c\/td\u003e\n\u003ctd\u003e500mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOhms Range\u003c\/td\u003e\n\u003ctd\u003e60.00kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e5 to 500.0Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1μF to 1,000μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 376F Clamp Meter\u003c\/li\u003e\n\u003cli\u003e18-inch iFlex® Flexible Current Probe\u003c\/li\u003e\n\u003cli\u003eTPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eTL75 test leads\u003c\/li\u003e\n\u003cli\u003eTwo AA Alkaline batteries\u003c\/li\u003e\n\u003cli\u003eCoated instruction card\u003c\/li\u003e\n\u003cli\u003eSafety information sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","published_at":"2022-03-18T09:20:20-06:00","created_at":"2022-03-18T09:18:10-06:00","vendor":"Fluke","type":"Clamp Meters","tags":[],"price":0,"price_min":0,"price_max":0,"available":false,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41297019175102,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-376","requires_shipping":true,"taxable":true,"featured_image":null,"available":false,"name":"Fluke 376 True-RMS AC\/DC Clamp Meter, No Fluke Connect","public_title":null,"options":["Default Title"],"price":0,"weight":1361,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke376NonFC.jpg?v=1647616775"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke376NonFC.jpg?v=1647616775","options":["Title"],"media":[{"alt":null,"id":23208482701502,"position":1,"preview_image":{"aspect_ratio":1.333,"height":600,"width":800,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke376NonFC.jpg?v=1647616775"},"aspect_ratio":1.333,"height":600,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke376NonFC.jpg?v=1647616775","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 376 True-rms AC\/DC Clamp Meter includes the iFlex™ Flexible Current Probe and measures up to  1000 V and 1000 A, AC or DC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*This unit is no longer available - See the Fluke 376FC replacement*\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eiFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (included)\u003c\/li\u003e\n\u003cli\u003eTPAK magnetic hanging strap (included)\u003c\/li\u003e\n\u003cli\u003eIntegrated VFD low pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eProprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it\u003c\/li\u003e\n\u003cli\u003eCAT IV 600 V, CAT III 1000 V safety rating\u003c\/li\u003e\n\u003cli\u003eThree-year warranty\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Capability\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1000 A ac and dc current measurement\u003c\/li\u003e\n\u003cli\u003e2500 A ac current measurement with iFlex flexible current probe\u003c\/li\u003e\n\u003cli\u003e1000 V ac and dc voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue-rms voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eFrequency measurement to 500 Hz with body jaw and iFlex\u003c\/li\u003e\n\u003cli\u003eResistance measurement to 60 kΩ with continuity detection\u003c\/li\u003e\n\u003cli\u003eMin, max, average, and inrush recording to capture variations automatically\u003c\/li\u003e\n\u003cli\u003e500 mV dc measurement range to interface with other accessories\u003c\/li\u003e\n\u003cli\u003e1000 μF capacitance measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT Rating\u003c\/td\u003e\n\u003ctd\u003eCAT III 1000V, CAT IV 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent AC Range\u003c\/td\u003e\n\u003ctd\u003e999.9A with clamp jaws\u003cbr\u003e2500A with iFlex flexible current clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC Range\u003c\/td\u003e\n\u003ctd\u003e999.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e1000V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV DC Range\u003c\/td\u003e\n\u003ctd\u003e500mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOhms Range\u003c\/td\u003e\n\u003ctd\u003e60.00kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e5 to 500.0Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1μF to 1,000μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 376F Clamp Meter\u003c\/li\u003e\n\u003cli\u003e18-inch iFlex® Flexible Current Probe\u003c\/li\u003e\n\u003cli\u003eTPAK magnetic hanging strap\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eTL75 test leads\u003c\/li\u003e\n\u003cli\u003eTwo AA Alkaline batteries\u003c\/li\u003e\n\u003cli\u003eCoated instruction card\u003c\/li\u003e\n\u003cli\u003eSafety information sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e"}
Fluke 376 True-RMS AC/DC Clamp Meter, No Fluke Connect

Fluke 376 True-RMS AC/DC Clamp Meter, No Fluke Connect

Call for pricing

The Fluke 376 True-rms AC/DC Clamp Meter includes the iFlex™ Flexible Current Probe and measures up to  1000 V and 1000 A, AC or DC. *This unit is no longer available - See the Fluke 376FC replacement* Overview iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces (include...


More Info
{"id":6939402567870,"title":"Fluke 393 FC CAT III True RMS Wireless Clamp Meter with iFlex, 1500 V","handle":"fluke-393-fc-cat-iii-true-rms-wireless-clamp-meter-with-iflex-1500-v","description":"\u003cp\u003e\u003cspan\u003eSafely and accurately measure up to 1500 V in DC environments with this rugged CAT III True-RMS Clamp Meter. IP54-rated and with a narrow jaw design, this meter is ideal for tight spaces and provides access to cables in crowded combiner boxes. The included iFlex current probe extends AC measurements up to 2500 A.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is designed for technicians who work in high voltage dc environment: solar arrays, wind power, electric railways, data centers battery banks for uninterruptible power supplies. The clamp will measure up to 1500 V dc, 1000 V ac, and up to 999.9 A dc or ac through the clamp jaw.  The included iFlex flexible current probe extended ac current measurements up to 2500 amps.This clamp has a thin jaw, giving you access to cables in crowded combiner boxes. Test leads are designed with your work in mind, and are also rated to CAT III 1500 V dc.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cspan\u003eOther key functions:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIP54 rated, ideal for work outdoors on solar arrays and wind power systems \u003c\/li\u003e\n\u003cli\u003eDC power measurement, showing readings in kVA\u003c\/li\u003e\n\u003cli\u003eAudio Polarity indicator helps prevent accidental miswires\u003c\/li\u003e\n\u003cli\u003eVisual Continuity turns provide a bright green light in the display, ideal when working in dark and noisy environments\u003c\/li\u003e\n\u003cli\u003eLogging and reporting of test results via Fluke Connect software\u003c\/li\u003e\n\u003cli\u003eWhen measuring ac current the included iFlex flexible current probe gives you unparalleled access to cable is tight spaces.  The iFlex probe can be twisted through extremely small spaces and provide accurate current measurements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAC Current Jaw\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% + 5 digits (10 to 100 Hz)\u003cbr\u003e2.5% + 5 digits (100 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd\u003e2.5 at 600 A\u003cbr\u003e3 at 500 A\u003cbr\u003e1.42 at 999.9 A\u003cbr\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFlexible Current Probe AC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003cbr\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A (≤999.9 A) 1 A (≤2500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e3% RD + 5 digits (10 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd\u003e2.5 at 1400 A\u003cbr\u003e3 at 1100 A\u003cbr\u003e1.42 at 2500 A\u003cbr\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% RD + 5 digits (when using the ZERO function to compensate for offsets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600 V\u003cbr\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V (≤600 V)\u003cbr\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits (20 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600 V\u003cbr\u003e1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V (≤600 V)\u003cbr\u003e1 V (≤1500 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003emV DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e500 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eJaw Amps Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd\u003e5 to 10 Hz, ≥10 A\u003cbr\u003e10 to 100 Hz, ≥5 A\u003cbr\u003e100 to 500 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFlexible Current Probe Amps Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd\u003e5 to 20 Hz, ≥25 A\u003cbr\u003e20 to 100 Hz, ≥20 A\u003cbr\u003e100 to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVoltage Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd\u003e5 to 20 Hz, ≥5 V\u003cbr\u003e20 to 100 Hz, ≥5 V\u003cbr\u003e100 to 500 Hz, ≥10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600 kVA (600 V DC range)\u003cbr\u003e1500 kVA (1500 V DC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 kVA\u003cbr\u003e1 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% RD + 2 KVA\u003cbr\u003e2% RD + 20 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600 Ω\u003cbr\u003e6000 Ω\u003cbr\u003e60 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω (≤600 Ω)\u003cbr\u003e1 Ω (≤6000 Ω)\u003cbr\u003e0.01 kΩ (≤60.00 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e100.0 μF\u003cbr\u003e1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 μF (≤100.0 μF)\u003cbr\u003e1 μF (≤1000 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Trigger Level\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eOperating: 14 to 122°F (-10 to 50°C)\u003cbr\u003eStorage: -40 to 140°F (-40 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003eNon-condensing (\u0026lt;10°C)\u003cbr\u003e≤90% RH at 50 to 86°F (10 to 30°C)\u003cbr\u003e≤75% RH at 86 to 104°F (30 to 40°C)\u003cbr\u003e≤45% RH at 104 to 122°F (40 to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating: 6562' (2000 m)\u003cbr\u003eStorage: 39370' (12000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage (Between Terminal and Earth Ground)\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003cbr\u003e1500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd\u003e2 AA IEC LR6 alkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDual display with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic power off\u003c\/td\u003e\n\u003ctd\u003e20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd\u003e1.3 \" (34 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe Diameter\u003c\/td\u003e\n\u003ctd\u003e0.29\" (7.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe Cable Length\u003c\/td\u003e\n\u003ctd\u003e5.9' (1.8 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11 x 3.3 x 1.9\" (281 x 84 x 49 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eClamp Meter\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003cli\u003eFlexible Current Probe\u003c\/li\u003e\n\u003cli\u003eMagnetic Hanging Strap\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_393.pdf?v=1630614745\" target=\"_blank\" title=\"Fluke 393 FC CAT III True RMS Wireless Clamp Meter with iFlex, 1500V Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 393 FC CAT III True RMS Wireless Clamp Meter with iFlex, 1500 V Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-09-02T14:39:30-06:00","created_at":"2021-09-02T14:39:29-06:00","vendor":"Fluke","type":"Clamp Meters","tags":[],"price":108799,"price_min":108799,"price_max":108799,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":40563976700094,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-393FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 393 FC CAT III True RMS Wireless Clamp Meter with iFlex, 1500 V","public_title":null,"options":["Default Title"],"price":108799,"weight":907,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke-393-FC.jpg?v=1630615170"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke-393-FC.jpg?v=1630615170","options":["Title"],"media":[{"alt":null,"id":22024660877502,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke-393-FC.jpg?v=1630615170"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke-393-FC.jpg?v=1630615170","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eSafely and accurately measure up to 1500 V in DC environments with this rugged CAT III True-RMS Clamp Meter. IP54-rated and with a narrow jaw design, this meter is ideal for tight spaces and provides access to cables in crowded combiner boxes. The included iFlex current probe extends AC measurements up to 2500 A.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex is designed for technicians who work in high voltage dc environment: solar arrays, wind power, electric railways, data centers battery banks for uninterruptible power supplies. The clamp will measure up to 1500 V dc, 1000 V ac, and up to 999.9 A dc or ac through the clamp jaw.  The included iFlex flexible current probe extended ac current measurements up to 2500 amps.This clamp has a thin jaw, giving you access to cables in crowded combiner boxes. Test leads are designed with your work in mind, and are also rated to CAT III 1500 V dc.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cspan\u003eOther key functions:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIP54 rated, ideal for work outdoors on solar arrays and wind power systems \u003c\/li\u003e\n\u003cli\u003eDC power measurement, showing readings in kVA\u003c\/li\u003e\n\u003cli\u003eAudio Polarity indicator helps prevent accidental miswires\u003c\/li\u003e\n\u003cli\u003eVisual Continuity turns provide a bright green light in the display, ideal when working in dark and noisy environments\u003c\/li\u003e\n\u003cli\u003eLogging and reporting of test results via Fluke Connect software\u003c\/li\u003e\n\u003cli\u003eWhen measuring ac current the included iFlex flexible current probe gives you unparalleled access to cable is tight spaces.  The iFlex probe can be twisted through extremely small spaces and provide accurate current measurements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAC Current Jaw\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% + 5 digits (10 to 100 Hz)\u003cbr\u003e2.5% + 5 digits (100 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd\u003e2.5 at 600 A\u003cbr\u003e3 at 500 A\u003cbr\u003e1.42 at 999.9 A\u003cbr\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFlexible Current Probe AC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003cbr\u003e2500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A (≤999.9 A) 1 A (≤2500 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e3% RD + 5 digits (10 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrest Factor (50\/60 Hz)\u003c\/td\u003e\n\u003ctd\u003e2.5 at 1400 A\u003cbr\u003e3 at 1100 A\u003cbr\u003e1.42 at 2500 A\u003cbr\u003eAdd 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e999.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% RD + 5 digits (when using the ZERO function to compensate for offsets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600 V\u003cbr\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V (≤600 V)\u003cbr\u003e1 V (≤1000 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits (20 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600 V\u003cbr\u003e1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V (≤600 V)\u003cbr\u003e1 V (≤1500 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003emV DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e500 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eJaw Amps Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd\u003e5 to 10 Hz, ≥10 A\u003cbr\u003e10 to 100 Hz, ≥5 A\u003cbr\u003e100 to 500 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFlexible Current Probe Amps Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd\u003e5 to 20 Hz, ≥25 A\u003cbr\u003e20 to 100 Hz, ≥20 A\u003cbr\u003e100 to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVoltage Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger Level\u003c\/td\u003e\n\u003ctd\u003e5 to 20 Hz, ≥5 V\u003cbr\u003e20 to 100 Hz, ≥5 V\u003cbr\u003e100 to 500 Hz, ≥10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600 kVA (600 V DC range)\u003cbr\u003e1500 kVA (1500 V DC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 kVA\u003cbr\u003e1 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2% RD + 2 KVA\u003cbr\u003e2% RD + 20 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e600 Ω\u003cbr\u003e6000 Ω\u003cbr\u003e60 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω (≤600 Ω)\u003cbr\u003e1 Ω (≤6000 Ω)\u003cbr\u003e0.01 kΩ (≤60.00 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e100.0 μF\u003cbr\u003e1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 μF (≤100.0 μF)\u003cbr\u003e1 μF (≤1000 μF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% RD + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Trigger Level\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eOperating: 14 to 122°F (-10 to 50°C)\u003cbr\u003eStorage: -40 to 140°F (-40 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003eNon-condensing (\u0026lt;10°C)\u003cbr\u003e≤90% RH at 50 to 86°F (10 to 30°C)\u003cbr\u003e≤75% RH at 86 to 104°F (30 to 40°C)\u003cbr\u003e≤45% RH at 104 to 122°F (40 to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eOperating: 6562' (2000 m)\u003cbr\u003eStorage: 39370' (12000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage (Between Terminal and Earth Ground)\u003c\/td\u003e\n\u003ctd\u003e1000 V AC\u003cbr\u003e1500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd\u003e2 AA IEC LR6 alkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDual display with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic power off\u003c\/td\u003e\n\u003ctd\u003e20 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd\u003e1.3 \" (34 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe Diameter\u003c\/td\u003e\n\u003ctd\u003e0.29\" (7.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexible Current Probe Cable Length\u003c\/td\u003e\n\u003ctd\u003e5.9' (1.8 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11 x 3.3 x 1.9\" (281 x 84 x 49 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eClamp Meter\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003cli\u003eFlexible Current Probe\u003c\/li\u003e\n\u003cli\u003eMagnetic Hanging Strap\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_393.pdf?v=1630614745\" target=\"_blank\" title=\"Fluke 393 FC CAT III True RMS Wireless Clamp Meter with iFlex, 1500V Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 393 FC CAT III True RMS Wireless Clamp Meter with iFlex, 1500 V Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 393 FC CAT III True RMS Wireless Clamp Meter with iFlex, 1500 V

Fluke 393 FC CAT III True RMS Wireless Clamp Meter with iFlex, 1500 V

$1,087.99 CAD

Safely and accurately measure up to 1500 V in DC environments with this rugged CAT III True-RMS Clamp Meter. IP54-rated and with a narrow jaw design, this meter is ideal for tight spaces and provides access to cables in crowded combiner boxes. The included iFlex current probe extends AC measurements up to 2500 A. Overview The 393 FC CAT III 150...


More Info
{"id":6624533905598,"title":"Fluke 378FC Non-Contact True RMS AC\/DC Clamp Meter w\/ Power Quality Indicator","handle":"fluke-378fc-non-contact-true-rms-ac-dc-clamp-meter-w-power-quality-indicator","description":"\u003cp\u003eThe Fluke 378 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.\u003c\/p\u003e\n\u003ch3\u003ePower quality indicator shows whether a problem is in the equipment or the power line\u003c\/h3\u003e\n\u003cp\u003eThe 378 FC clamp meter includes a unique PQ function that senses power quality issues automatically. When making FieldSense measurements, the 378 FC will detect and display power quality issues, relating to current, voltage, power factor or any combination of the three. Now you can quickly determine if an upstream supply problem exists, or if there is a downstream equipment problem.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/Fykn84SHes0\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure voltage and current with your clamp jaw\u003c\/li\u003e\n\u003cli\u003eFaster, safer testing all without touching a live wire using FieldSense™ technology\u003c\/li\u003e\n\u003cli\u003eComplete three-phase voltage and current tests in three quick steps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower quality indicator shows whether a problem is in the equipment or the power line\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis clamp meter includes a unique PQ function that senses power quality issues automatically. When making FieldSense measurements, it will detect and display power quality issues, relating to current, voltage, power factor or any combination of the three. Now you can quickly determine if an upstream supply problem exists, or if there is a downstream equipment problem.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage and current measurements with FieldSense™ technology\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo more hand-written notes or complicated math.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete 3-phase voltage and current tests in three easy steps\u003c\/li\u003e\n\u003cli\u003eFull set of phase-to-ground and phase-to-phase values calculated\u003c\/li\u003e\n\u003cli\u003eDisplayed on your smart phone and saved to the cloud via Fluke Connect software\u003c\/li\u003e\n\u003cli\u003ePhase rotation calculated and shown on the Fluke Connect software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasure extremely high current with iFlex™ probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy to see, easy to use with included tools\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYour job will get easier when you use this clamp meter:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe display turns green when a stable FieldSense measurement is detected\u003c\/li\u003e\n\u003cli\u003eVisual Continuity provides a bright green screen for easy detection of continuity in noisy work areas\u003c\/li\u003e\n\u003cli\u003eThe magnetic hanging kit, with 9\" (23 cm) hanging strap, lets you hang your clamp wherever you need: to a steel cabinet door; around a pipe; on a nail or screw head\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19px;\"\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 114px;\"\u003e\n\u003ctd style=\"height: 114px;\"\u003eAC - Jaw\u003c\/td\u003e\n\u003ctd style=\"height: 114px;\"\u003eRange: 999.9 A\u003cbr\u003eResolution: 0.1 A\u003cbr\u003eAccuracy: 2% ±5 digits (10 to 100 Hz); 2.5% ±5 digits (100 to 500 Hz)\u003cbr\u003eCrest factor (50\/60 Hz): 3 at 500 A; 2.5 at 600 A; 1.42 at 1000 A; Add 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eAC - Flexible Current Probe\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 2500 A\u003cbr\u003eResolution: 1 A (≤2500 A) 0.1 A (≤999.9 A)\u003cbr\u003eAccuracy: 3% ±5 digits (5 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eDC\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 999.9 A\u003cbr\u003eResolution: 0.1 A\u003cbr\u003eAccuracy: 2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 76px;\"\u003e\n\u003ctd style=\"height: 76px;\"\u003eAC - FieldSense\u003c\/td\u003e\n\u003ctd style=\"height: 76px;\"\u003eRange: 1000 V\u003cbr\u003eResolution: 1 V (≤1000 V)\u003cbr\u003eAccuracy: ≤4\/0 AWG - 3% ±5 digits (45 to 66 Hz); ≥4\/0 AWG - 5% ±5 digits (45 to 66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eAC - Test Leads\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 600.0 V, 1000 V\u003cbr\u003eResolution: 0.1 V (≤600.0 V); 1 V (≤1000 V)\u003cbr\u003eAccuracy: 1% ±5 digits (20 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eDC\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 600 V, 1000 V\u003cbr\u003eResolution: 0.1 V (≤600 V); 1 V (≤1000 V)\u003cbr\u003eAccuracy: 1% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003emV DC\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 500 mV\u003cbr\u003eResolution: 0.1 mV\u003cbr\u003eAccuracy: 1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19px;\"\u003e\u003cstrong\u003eAmps Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 95px;\"\u003e\n\u003ctd style=\"height: 95px;\"\u003eJaw\u003c\/td\u003e\n\u003ctd style=\"height: 95px;\"\u003eRange: 5 to 500 Hz\u003cbr\u003eResolution: 0.1 Hz\u003cbr\u003eAccuracy: 0.5% ±5 digits\u003cbr\u003eTrigger level: 5 to 10 Hz, ≥10 A; 10 to 100 Hz, ≥5 A; 100 to 500 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 95px;\"\u003e\n\u003ctd style=\"height: 95px;\"\u003eFlexible Current Probe\u003c\/td\u003e\n\u003ctd style=\"height: 95px;\"\u003eRange: 5 to 500 Hz\u003cbr\u003eResolution: 0.1 Hz\u003cbr\u003eAccuracy: 0.5% ±5 digits\u003cbr\u003eTrigger level: 5 to 20 Hz, ≥25 A; 20 to 100 Hz, ≥20 A; 100 to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19px;\"\u003e\u003cstrong\u003eOther Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 60 kΩ, 6000 Ω, 600 Ω\u003cbr\u003eResolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 10 Ω (≤60 kΩ)\u003cbr\u003eAccuracy: 1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 1000 μF\u003cbr\u003eResolution: 0.1 μF (≤100 μF), 1 F (≤1000 μF)\u003cbr\u003eAccuracy: 1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 5.375px;\"\u003e\n\u003ctd style=\"height: 5.375px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 5.375px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 12px;\"\u003e\n\u003ctd style=\"height: 12px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 12px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 378 FC Non-Contact Voltage True-RMS AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003eTL224 Test Leads\u003c\/li\u003e\n\u003cli\u003eTP175 TwistGuard™ Test Probes\u003c\/li\u003e\n\u003cli\u003eAC285 black grounding clip (1 only)\u003c\/li\u003e\n\u003cli\u003ei2500-18 iFlex® Flexible Current Probes 18 inch (48 cm)\u003c\/li\u003e\n\u003cli\u003eTPAK ToolPak™ Magnetic Meter Hanger\u003c\/li\u003e\n\u003cli\u003ePremium carrying case\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_377-378_Clamp_Meter_Spec_Sheet.pdf?v=1618499642\" title=\"Fluke 377FC Non-Contact True RMS AC\/DC Clamp Meter\" target=\"_blank\"\u003eFluke 378FC Non-Contact True RMS AC\/DC Clamp Meter) Spec Sheet\u003c\/a\u003e\u003c!-- split --\u003e","published_at":"2021-04-15T10:16:55-06:00","created_at":"2021-04-15T10:08:52-06:00","vendor":"Fluke","type":"Clamp Meters","tags":[],"price":126479,"price_min":126479,"price_max":126479,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39547193426110,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-378FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 378FC Non-Contact True RMS AC\/DC Clamp Meter w\/ Power Quality Indicator","public_title":null,"options":["Default Title"],"price":126479,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969916615","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378.jpg?v=1618503371","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378_2.jpg?v=1618503381","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378_3.jpg?v=1618503393","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377Pic2_c52650d4-67e0-407b-ab96-5821114739d9.jpg?v=1620740477"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378.jpg?v=1618503371","options":["Title"],"media":[{"alt":null,"id":20588553404606,"position":1,"preview_image":{"aspect_ratio":0.487,"height":1500,"width":731,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378.jpg?v=1618503371"},"aspect_ratio":0.487,"height":1500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378.jpg?v=1618503371","width":731},{"alt":null,"id":20588554027198,"position":2,"preview_image":{"aspect_ratio":0.791,"height":1500,"width":1187,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378_2.jpg?v=1618503381"},"aspect_ratio":0.791,"height":1500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378_2.jpg?v=1618503381","width":1187},{"alt":null,"id":20588554420414,"position":3,"preview_image":{"aspect_ratio":1.499,"height":1001,"width":1500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378_3.jpg?v=1618503393"},"aspect_ratio":1.499,"height":1001,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke378_3.jpg?v=1618503393","width":1500},{"alt":null,"id":20844773376190,"position":4,"preview_image":{"aspect_ratio":0.714,"height":1500,"width":1071,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377Pic2_c52650d4-67e0-407b-ab96-5821114739d9.jpg?v=1620740477"},"aspect_ratio":0.714,"height":1500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke377Pic2_c52650d4-67e0-407b-ab96-5821114739d9.jpg?v=1620740477","width":1071}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe Fluke 378 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.\u003c\/p\u003e\n\u003ch3\u003ePower quality indicator shows whether a problem is in the equipment or the power line\u003c\/h3\u003e\n\u003cp\u003eThe 378 FC clamp meter includes a unique PQ function that senses power quality issues automatically. When making FieldSense measurements, the 378 FC will detect and display power quality issues, relating to current, voltage, power factor or any combination of the three. Now you can quickly determine if an upstream supply problem exists, or if there is a downstream equipment problem.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/Fykn84SHes0\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure voltage and current with your clamp jaw\u003c\/li\u003e\n\u003cli\u003eFaster, safer testing all without touching a live wire using FieldSense™ technology\u003c\/li\u003e\n\u003cli\u003eComplete three-phase voltage and current tests in three quick steps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower quality indicator shows whether a problem is in the equipment or the power line\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis clamp meter includes a unique PQ function that senses power quality issues automatically. When making FieldSense measurements, it will detect and display power quality issues, relating to current, voltage, power factor or any combination of the three. Now you can quickly determine if an upstream supply problem exists, or if there is a downstream equipment problem.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage and current measurements with FieldSense™ technology\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo more hand-written notes or complicated math.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplete 3-phase voltage and current tests in three easy steps\u003c\/li\u003e\n\u003cli\u003eFull set of phase-to-ground and phase-to-phase values calculated\u003c\/li\u003e\n\u003cli\u003eDisplayed on your smart phone and saved to the cloud via Fluke Connect software\u003c\/li\u003e\n\u003cli\u003ePhase rotation calculated and shown on the Fluke Connect software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasure extremely high current with iFlex™ probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy to see, easy to use with included tools\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYour job will get easier when you use this clamp meter:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe display turns green when a stable FieldSense measurement is detected\u003c\/li\u003e\n\u003cli\u003eVisual Continuity provides a bright green screen for easy detection of continuity in noisy work areas\u003c\/li\u003e\n\u003cli\u003eThe magnetic hanging kit, with 9\" (23 cm) hanging strap, lets you hang your clamp wherever you need: to a steel cabinet door; around a pipe; on a nail or screw head\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19px;\"\u003e\u003cstrong\u003eCurrent\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 114px;\"\u003e\n\u003ctd style=\"height: 114px;\"\u003eAC - Jaw\u003c\/td\u003e\n\u003ctd style=\"height: 114px;\"\u003eRange: 999.9 A\u003cbr\u003eResolution: 0.1 A\u003cbr\u003eAccuracy: 2% ±5 digits (10 to 100 Hz); 2.5% ±5 digits (100 to 500 Hz)\u003cbr\u003eCrest factor (50\/60 Hz): 3 at 500 A; 2.5 at 600 A; 1.42 at 1000 A; Add 2% for C.F. \u0026gt;2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eAC - Flexible Current Probe\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 2500 A\u003cbr\u003eResolution: 1 A (≤2500 A) 0.1 A (≤999.9 A)\u003cbr\u003eAccuracy: 3% ±5 digits (5 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eDC\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 999.9 A\u003cbr\u003eResolution: 0.1 A\u003cbr\u003eAccuracy: 2% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19px;\"\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 76px;\"\u003e\n\u003ctd style=\"height: 76px;\"\u003eAC - FieldSense\u003c\/td\u003e\n\u003ctd style=\"height: 76px;\"\u003eRange: 1000 V\u003cbr\u003eResolution: 1 V (≤1000 V)\u003cbr\u003eAccuracy: ≤4\/0 AWG - 3% ±5 digits (45 to 66 Hz); ≥4\/0 AWG - 5% ±5 digits (45 to 66 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eAC - Test Leads\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 600.0 V, 1000 V\u003cbr\u003eResolution: 0.1 V (≤600.0 V); 1 V (≤1000 V)\u003cbr\u003eAccuracy: 1% ±5 digits (20 to 500 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eDC\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 600 V, 1000 V\u003cbr\u003eResolution: 0.1 V (≤600 V); 1 V (≤1000 V)\u003cbr\u003eAccuracy: 1% ± 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003emV DC\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 500 mV\u003cbr\u003eResolution: 0.1 mV\u003cbr\u003eAccuracy: 1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19px;\"\u003e\u003cstrong\u003eAmps Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 95px;\"\u003e\n\u003ctd style=\"height: 95px;\"\u003eJaw\u003c\/td\u003e\n\u003ctd style=\"height: 95px;\"\u003eRange: 5 to 500 Hz\u003cbr\u003eResolution: 0.1 Hz\u003cbr\u003eAccuracy: 0.5% ±5 digits\u003cbr\u003eTrigger level: 5 to 10 Hz, ≥10 A; 10 to 100 Hz, ≥5 A; 100 to 500 Hz, ≥10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 95px;\"\u003e\n\u003ctd style=\"height: 95px;\"\u003eFlexible Current Probe\u003c\/td\u003e\n\u003ctd style=\"height: 95px;\"\u003eRange: 5 to 500 Hz\u003cbr\u003eResolution: 0.1 Hz\u003cbr\u003eAccuracy: 0.5% ±5 digits\u003cbr\u003eTrigger level: 5 to 20 Hz, ≥25 A; 20 to 100 Hz, ≥20 A; 100 to 500 Hz, ≥25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 19px;\"\u003e\u003cstrong\u003eOther Measurements\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eResistance\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 60 kΩ, 6000 Ω, 600 Ω\u003cbr\u003eResolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 10 Ω (≤60 kΩ)\u003cbr\u003eAccuracy: 1% ±5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 57px;\"\u003e\n\u003ctd style=\"height: 57px;\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd style=\"height: 57px;\"\u003eRange: 1000 μF\u003cbr\u003eResolution: 0.1 μF (≤100 μF), 1 F (≤1000 μF)\u003cbr\u003eAccuracy: 1% ±4 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd colspan=\"2\" style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 5.375px;\"\u003e\n\u003ctd style=\"height: 5.375px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 5.375px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 10px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 12px;\"\u003e\n\u003ctd style=\"height: 12px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 12px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 378 FC Non-Contact Voltage True-RMS AC\/DC Clamp Meter\u003c\/li\u003e\n\u003cli\u003eTL224 Test Leads\u003c\/li\u003e\n\u003cli\u003eTP175 TwistGuard™ Test Probes\u003c\/li\u003e\n\u003cli\u003eAC285 black grounding clip (1 only)\u003c\/li\u003e\n\u003cli\u003ei2500-18 iFlex® Flexible Current Probes 18 inch (48 cm)\u003c\/li\u003e\n\u003cli\u003eTPAK ToolPak™ Magnetic Meter Hanger\u003c\/li\u003e\n\u003cli\u003ePremium carrying case\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_377-378_Clamp_Meter_Spec_Sheet.pdf?v=1618499642\" title=\"Fluke 377FC Non-Contact True RMS AC\/DC Clamp Meter\" target=\"_blank\"\u003eFluke 378FC Non-Contact True RMS AC\/DC Clamp Meter) Spec Sheet\u003c\/a\u003e\u003c!-- split --\u003e"}
Fluke 378FC Non-Contact True RMS AC/DC Clamp Meter w/ Power Quality Indicator

Fluke 378FC Non-Contact True RMS AC/DC Clamp Meter w/ Power Quality Indicator

$1,264.79 CAD

The Fluke 378 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage a...


More Info
{"id":6179674259646,"title":"AEMC 605 True RMS Power Clamp Meter with Phase Rotation, 1000V AC\/DC, 2000A AC\/3000A DC","handle":"aemc-605-true-rms-power-clamp-meter-with-phase-rotation-1000v-ac-dc-2000a-ac-3000a-dc","description":"\u003cp\u003e\u003cspan\u003eThe TRMS Power Clamp-on Meter Model 605 provides a new standard for safety and measurement capability not available in any other clamp meter sold today. Safety Rated at 1000V CAT IV, it is safe to operate in most electrical environments. It is rugged enough for the most demanding work environments and will withstand both dust and water spray with its IP54 rating. It is ergonomically designed and easily used by one hand, including function selection and button pushing even with a glove on. In addition to the standard measurement of volts, amps, frequency, resistance, diode checking and continuity, the Model 605 offers several unequaled functions including: AC, DC and AC+DC volts, amps and power,\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.aemc.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003csup\u003e®\u003c\/sup\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cspan\u003e, Delta relative function, phase rotation indication, power measurements, and more.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1000V CAT IV Rated\u003c\/li\u003e\n\u003cli\u003eUL 94 flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003eIP54 Rated\u003c\/li\u003e\n\u003cli\u003e10,000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1000VDC and AC+DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 2000AAC and 3000ADC\u003c\/li\u003e\n\u003cli\u003eMeasures single- and three-phase power (real, reactive and apparent) up to 3MW with resolution to 1W\u003c\/li\u003e\n\u003cli\u003eDisplays Power Factor\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC measurement\u003c\/li\u003e\n\u003cli\u003eMeasures AC+DC volts, amps and power\u003c\/li\u003e\n\u003cli\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ecurrent measurement with 1mS capture\u003c\/li\u003e\n\u003cli\u003eMeasures THDr and THDf  \u003c\/li\u003e\n\u003cli\u003eDetects and displays phase rotation\u003c\/li\u003e\n\u003cli\u003eDelta relative function for tracking deviation from reference values\u003c\/li\u003e\n\u003cli\u003eTracks Min\/Max values\u003c\/li\u003e\n\u003cli\u003eJaw opening up to 2.36\"\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Vrms AC\/DC\/AC+DC Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2000Arms AC, 3000ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTrue InRush®:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e10 to 1000AAC, 10 to 1500ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Measurement Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2MW AC, 3MW DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTHD:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes, %f and %r\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eSelectable from 0 to 999.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e100kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDiode Test:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0 to 3.2VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e20kHz in V, 2kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Factor:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePhase Order:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eMIN\/MAX\/PEAK-\/PEAK+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003e∆REL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e4 x AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e\u0026gt;350 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e11.65 x 4.37 x 1.61\" (296 x 111 x 41mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.4 lbs (640g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2.36\" (60mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-4° to +131°F (-20 to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-40° to +158°F (-40 to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN\/IEC 61010-1 to 1000V CAT IV\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Power Clamp-on Meter with Phase Rotation\u003c\/li\u003e\n\u003cli\u003e2152.03 Silicone Lead Set, 1000V CAT IV\u003c\/li\u003e\n\u003cli\u003e2139.72 Soft Case\u003c\/li\u003e\n\u003cli\u003eSet of 4 AA 1.2V Batteries\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_200-400-600_Series_Clamps_-_High_Current_Spec.pdf?v=1610036163\" target=\"_blank\" title=\"AEMC 605 True RMS Power Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 605 True RMS Power Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-18T12:29:00-07:00","created_at":"2021-01-18T12:28:59-07:00","vendor":"AEMC Instruments","type":"Clamp Meters","tags":[],"price":67400,"price_min":67400,"price_max":67400,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37911668195518,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2139.60","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 605 True RMS Power Clamp Meter with Phase Rotation, 1000V AC\/DC, 2000A AC\/3000A DC","public_title":null,"options":["Default Title"],"price":67400,"weight":4082,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338220438","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC605Pic1.png?v=1610998143"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC605Pic1.png?v=1610998143","options":["Title"],"media":[{"alt":null,"id":15455056494782,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC605Pic1.png?v=1610998143"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC605Pic1.png?v=1610998143","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe TRMS Power Clamp-on Meter Model 605 provides a new standard for safety and measurement capability not available in any other clamp meter sold today. Safety Rated at 1000V CAT IV, it is safe to operate in most electrical environments. It is rugged enough for the most demanding work environments and will withstand both dust and water spray with its IP54 rating. It is ergonomically designed and easily used by one hand, including function selection and button pushing even with a glove on. In addition to the standard measurement of volts, amps, frequency, resistance, diode checking and continuity, the Model 605 offers several unequaled functions including: AC, DC and AC+DC volts, amps and power,\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.aemc.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003csup\u003e®\u003c\/sup\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cspan\u003e, Delta relative function, phase rotation indication, power measurements, and more.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1000V CAT IV Rated\u003c\/li\u003e\n\u003cli\u003eUL 94 flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003eIP54 Rated\u003c\/li\u003e\n\u003cli\u003e10,000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1000VDC and AC+DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 2000AAC and 3000ADC\u003c\/li\u003e\n\u003cli\u003eMeasures single- and three-phase power (real, reactive and apparent) up to 3MW with resolution to 1W\u003c\/li\u003e\n\u003cli\u003eDisplays Power Factor\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC measurement\u003c\/li\u003e\n\u003cli\u003eMeasures AC+DC volts, amps and power\u003c\/li\u003e\n\u003cli\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ecurrent measurement with 1mS capture\u003c\/li\u003e\n\u003cli\u003eMeasures THDr and THDf  \u003c\/li\u003e\n\u003cli\u003eDetects and displays phase rotation\u003c\/li\u003e\n\u003cli\u003eDelta relative function for tracking deviation from reference values\u003c\/li\u003e\n\u003cli\u003eTracks Min\/Max values\u003c\/li\u003e\n\u003cli\u003eJaw opening up to 2.36\"\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Vrms AC\/DC\/AC+DC Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2000Arms AC, 3000ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTrue InRush®:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e10 to 1000AAC, 10 to 1500ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Measurement Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2MW AC, 3MW DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTHD:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes, %f and %r\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eSelectable from 0 to 999.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e100kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDiode Test:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0 to 3.2VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e20kHz in V, 2kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Factor:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePhase Order:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eMIN\/MAX\/PEAK-\/PEAK+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003e∆REL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e4 x AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e\u0026gt;350 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e11.65 x 4.37 x 1.61\" (296 x 111 x 41mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.4 lbs (640g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2.36\" (60mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-4° to +131°F (-20 to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-40° to +158°F (-40 to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN\/IEC 61010-1 to 1000V CAT IV\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Power Clamp-on Meter with Phase Rotation\u003c\/li\u003e\n\u003cli\u003e2152.03 Silicone Lead Set, 1000V CAT IV\u003c\/li\u003e\n\u003cli\u003e2139.72 Soft Case\u003c\/li\u003e\n\u003cli\u003eSet of 4 AA 1.2V Batteries\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_200-400-600_Series_Clamps_-_High_Current_Spec.pdf?v=1610036163\" target=\"_blank\" title=\"AEMC 605 True RMS Power Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 605 True RMS Power Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 605 True RMS Power Clamp Meter with Phase Rotation, 1000V AC/DC, 2000A AC/3000A DC

AEMC 605 True RMS Power Clamp Meter with Phase Rotation, 1000V AC/DC, 2000A AC/3000A DC

$674.00 CAD

The TRMS Power Clamp-on Meter Model 605 provides a new standard for safety and measurement capability not available in any other clamp meter sold today. Safety Rated at 1000V CAT IV, it is safe to operate in most electrical environments. It is rugged enough for the most demanding work environments and will withstand both dust and water spray wit...


More Info
{"id":6179663610046,"title":"AEMC 405 True RMS Clamp Meter with Phase Rotation, 1000V AC\/DC, 1000A AC\/1500A DC","handle":"aemc-405-true-rms-clamp-meter-with-phase-rotation-1000v-ac-dc-1000a-ac-1500a-dc","description":"\u003cp\u003e\u003cspan\u003eThe True RMS Clamp-On Meter Model 405 is safety rated at 1000V CAT IV. AC DC clamp meter - it measures AC, DC, and AC+DC volts, amps and power. The Model 405 also measures resistance, frequency, \u003c\/span\u003e\u003ca href=\"http:\/\/aemc.skyworld.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003e\u003cstrong\u003e\u003cspan color=\"#004f92\" style=\"color: #004f92;\"\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003cspan\u003e\u003csup\u003e®\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003etemperature, phase rotation, and continuity. It can also perform diode checks. This rugged meter can operate in the most demanding work environments, and its IP54 rating allows it to withstand both dust and water spray.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1000V CAT IV Rated\u003c\/li\u003e\n\u003cli\u003eUL 94 flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003eIP54 Rated\u003c\/li\u003e\n\u003cli\u003e10,000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1000VDC and AC+DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000AAC and 1500ADC\u003c\/li\u003e\n\u003cli\u003eMeasures single- and three-phase power (real, reactive and apparent) up to 3MW with resolution to 1W\u003c\/li\u003e\n\u003cli\u003eDisplays Power Factor\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC measurement\u003c\/li\u003e\n\u003cli\u003eMeasures AC+DC volts, amps and power\u003c\/li\u003e\n\u003cli\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ecurrent measurement with 1mS capture\u003c\/li\u003e\n\u003cli\u003eMeasures THDr and THDf  \u003c\/li\u003e\n\u003cli\u003eDetects and displays phase rotation\u003c\/li\u003e\n\u003cli\u003eDelta relative function for tracking deviation from reference values\u003c\/li\u003e\n\u003cli\u003eTracks Min\/Max values\u003c\/li\u003e\n\u003cli\u003eJaw opening up to 1.89\"\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Vrms AC\/DC\/AC+DC Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Arms AC, 1500ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eInRush:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e10 to 1000AAC, 10 to 1500ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Measurement Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1MW AC, 1.5MW DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTHD:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes, %f and %r\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eSelectable from 0 to 999.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e100kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDiode Test:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0 to 3.2VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e20kHz in V, 2kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Factor:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePhase Order:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eMIN\/MAX\/PEAK-\/PEAK+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003e∆REL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e4 x AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e\u0026gt;350 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e10.7 x 3.6 x 1.6\" (272 x 92 x 41mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.32 lbs (600g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.9\" (48mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-4° to +131°F (-20° to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-40° to +158°F (-40° to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN\/IEC 61010-1 to 1000V CAT IV\u003cimg src=\"https:\/\/www.aemc.com\/userfiles\/images\/logos\/CE_Logo.png\" alt=\"\"\u003e\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Clamp-on Meter\u003c\/li\u003e\n\u003cli\u003e2152.03 Silicone Lead Set, 1000V, CAT IV Rated\u003c\/li\u003e\n\u003cli\u003e2139.72 Soft Carrying Case\u003c\/li\u003e\n\u003cli\u003eSet of 4 AA 1.2V Batteries\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_200-400-600_Series_Clamps_-_High_Current_Spec.pdf?v=1610036163\" target=\"_blank\" title=\"AEMC 405 True RMS Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 405 True RMS Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-18T12:22:52-07:00","created_at":"2021-01-18T12:22:51-07:00","vendor":"AEMC Instruments","type":"Clamp Meters","tags":[],"price":58100,"price_min":58100,"price_max":58100,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37911648534718,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2139.50","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 405 True RMS Clamp Meter with Phase Rotation, 1000V AC\/DC, 1000A AC\/1500A DC","public_title":null,"options":["Default Title"],"price":58100,"weight":4082,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338220414","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC405Pic1.png?v=1610997773"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC405Pic1.png?v=1610997773","options":["Title"],"media":[{"alt":null,"id":15455011668158,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC405Pic1.png?v=1610997773"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC405Pic1.png?v=1610997773","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe True RMS Clamp-On Meter Model 405 is safety rated at 1000V CAT IV. AC DC clamp meter - it measures AC, DC, and AC+DC volts, amps and power. The Model 405 also measures resistance, frequency, \u003c\/span\u003e\u003ca href=\"http:\/\/aemc.skyworld.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003e\u003cstrong\u003e\u003cspan color=\"#004f92\" style=\"color: #004f92;\"\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003cspan\u003e\u003csup\u003e®\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003etemperature, phase rotation, and continuity. It can also perform diode checks. This rugged meter can operate in the most demanding work environments, and its IP54 rating allows it to withstand both dust and water spray.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1000V CAT IV Rated\u003c\/li\u003e\n\u003cli\u003eUL 94 flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003eIP54 Rated\u003c\/li\u003e\n\u003cli\u003e10,000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1000VDC and AC+DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000AAC and 1500ADC\u003c\/li\u003e\n\u003cli\u003eMeasures single- and three-phase power (real, reactive and apparent) up to 3MW with resolution to 1W\u003c\/li\u003e\n\u003cli\u003eDisplays Power Factor\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC measurement\u003c\/li\u003e\n\u003cli\u003eMeasures AC+DC volts, amps and power\u003c\/li\u003e\n\u003cli\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ecurrent measurement with 1mS capture\u003c\/li\u003e\n\u003cli\u003eMeasures THDr and THDf  \u003c\/li\u003e\n\u003cli\u003eDetects and displays phase rotation\u003c\/li\u003e\n\u003cli\u003eDelta relative function for tracking deviation from reference values\u003c\/li\u003e\n\u003cli\u003eTracks Min\/Max values\u003c\/li\u003e\n\u003cli\u003eJaw opening up to 1.89\"\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Vrms AC\/DC\/AC+DC Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Arms AC, 1500ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eInRush:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e10 to 1000AAC, 10 to 1500ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Measurement Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1MW AC, 1.5MW DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTHD:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes, %f and %r\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eSelectable from 0 to 999.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e100kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDiode Test:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0 to 3.2VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e20kHz in V, 2kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Factor:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePhase Order:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eMIN\/MAX\/PEAK-\/PEAK+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003e∆REL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e4 x AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e\u0026gt;350 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e10.7 x 3.6 x 1.6\" (272 x 92 x 41mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.32 lbs (600g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.9\" (48mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-4° to +131°F (-20° to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-40° to +158°F (-40° to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN\/IEC 61010-1 to 1000V CAT IV\u003cimg src=\"https:\/\/www.aemc.com\/userfiles\/images\/logos\/CE_Logo.png\" alt=\"\"\u003e\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Clamp-on Meter\u003c\/li\u003e\n\u003cli\u003e2152.03 Silicone Lead Set, 1000V, CAT IV Rated\u003c\/li\u003e\n\u003cli\u003e2139.72 Soft Carrying Case\u003c\/li\u003e\n\u003cli\u003eSet of 4 AA 1.2V Batteries\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_200-400-600_Series_Clamps_-_High_Current_Spec.pdf?v=1610036163\" target=\"_blank\" title=\"AEMC 405 True RMS Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 405 True RMS Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 405 True RMS Clamp Meter with Phase Rotation, 1000V AC/DC, 1000A AC/1500A DC

AEMC 405 True RMS Clamp Meter with Phase Rotation, 1000V AC/DC, 1000A AC/1500A DC

$581.00 CAD

The True RMS Clamp-On Meter Model 405 is safety rated at 1000V CAT IV. AC DC clamp meter - it measures AC, DC, and AC+DC volts, amps and power. The Model 405 also measures resistance, frequency, True InRush®, temperature, phase rotation, and continuity. It can also perform diode checks. This rugged meter can operate in the most demanding work en...


More Info
{"id":6179653124286,"title":"AEMC 205 True RMS Clamp Meter with Phase Rotation, 600AAC\/900ADC","handle":"aemc-205-true-rms-clamp-meter-with-phase-rotation-600aac-900adc","description":"\u003cp\u003e\u003cspan\u003eThe True RMS Clamp-On Meter Model 205 is safety rated at 600V CAT IV. It measures AC+DC volts and amps, frequency, continuity, resistance, power and Power Factor, phase rotation, and THD. It can also perform diode checks. The Delta relative function compares new measurements to a reference value, and the MIN\/MAX function tracks high and low values. The Model 205 also tracks peak+ and peak– values. This compact and rugged meter can operate in demanding work environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUL94 VI flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003e6000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1400VDC and AC+DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 600AAC and 900ADC\u003c\/li\u003e\n\u003cli\u003eMeasures single- and three-phase power (real, reactive, and apparent) up to 600kW with resolution to 1W\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue InRush® current measurement with 1ms capture\u003c\/li\u003e\n\u003cli\u003eJaw opening to 1.33\" (34mm); IP54 Rated\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Vrms AC\/DC\/AC+DC Auto-ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e600Arms AC, 900ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eInRush:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e6 to 600AAC, 6 to 900ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Measurement Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e600kW AC, 900kW DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTHD:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes, %f and %r\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eSelectable from 0 to 599.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e60kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDiode Test:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0 to 3.2VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e20kHz in V, 3kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Factor:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePhase Order:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eMIN\/MAX\/PEAK-\/PEAK+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003e∆REL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1 x 9V, IEC LF22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e\u0026gt;120 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e8.7 x 3.0 x 1.65\" (222 x 78 x 42mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e12.0 oz. (340g) with battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.34\" (34mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-4° to +131°F (-20 to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-40° to +158°F (-40 to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN\/IEC 61010-1: 1000V CAT III, 600V CAT IV\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span10\"\u003e\n\u003cdiv class=\"mhide ipad-view-setting\"\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"row-fluid ProductTabs\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv id=\"tab2\" class=\"product-tabs tab-pane active\"\u003e\n\u003cli\u003eAEMC 205 True RMS Clamp Meter with Phase Rotation, 600AAC\/900ADC\u003c\/li\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row-fluid\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"span2 mhide ipad-view-setting\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_200-400-600_Series_Clamps_-_High_Current_Spec.pdf?v=1610036163\" target=\"_blank\" title=\"AEMC 205 True RMS Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 205 True RMS Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-18T12:16:38-07:00","created_at":"2021-01-18T12:16:38-07:00","vendor":"AEMC Instruments","type":"Clamp Meters","tags":[],"price":55300,"price_min":55300,"price_max":55300,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37911634215102,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2139.40","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 205 True RMS Clamp Meter with Phase Rotation, 600AAC\/900ADC","public_title":null,"options":["Default Title"],"price":55300,"weight":4082,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338220407","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC205Pic1.png?v=1610997400"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC205Pic1.png?v=1610997400","options":["Title"],"media":[{"alt":null,"id":15454978506942,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC205Pic1.png?v=1610997400"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC205Pic1.png?v=1610997400","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe True RMS Clamp-On Meter Model 205 is safety rated at 600V CAT IV. It measures AC+DC volts and amps, frequency, continuity, resistance, power and Power Factor, phase rotation, and THD. It can also perform diode checks. The Delta relative function compares new measurements to a reference value, and the MIN\/MAX function tracks high and low values. The Model 205 also tracks peak+ and peak– values. This compact and rugged meter can operate in demanding work environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUL94 VI flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003e6000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1400VDC and AC+DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 600AAC and 900ADC\u003c\/li\u003e\n\u003cli\u003eMeasures single- and three-phase power (real, reactive, and apparent) up to 600kW with resolution to 1W\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue InRush® current measurement with 1ms capture\u003c\/li\u003e\n\u003cli\u003eJaw opening to 1.33\" (34mm); IP54 Rated\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Vrms AC\/DC\/AC+DC Auto-ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e600Arms AC, 900ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eInRush:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e6 to 600AAC, 6 to 900ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Measurement Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e600kW AC, 900kW DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTHD:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes, %f and %r\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eSelectable from 0 to 599.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e60kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDiode Test:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0 to 3.2VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e20kHz in V, 3kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Factor:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePhase Order:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eMIN\/MAX\/PEAK-\/PEAK+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003e∆REL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1 x 9V, IEC LF22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e\u0026gt;120 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e8.7 x 3.0 x 1.65\" (222 x 78 x 42mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e12.0 oz. (340g) with battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.34\" (34mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-4° to +131°F (-20 to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-40° to +158°F (-40 to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN\/IEC 61010-1: 1000V CAT III, 600V CAT IV\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span10\"\u003e\n\u003cdiv class=\"mhide ipad-view-setting\"\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"row-fluid ProductTabs\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv id=\"tab2\" class=\"product-tabs tab-pane active\"\u003e\n\u003cli\u003eAEMC 205 True RMS Clamp Meter with Phase Rotation, 600AAC\/900ADC\u003c\/li\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row-fluid\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"span2 mhide ipad-view-setting\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_200-400-600_Series_Clamps_-_High_Current_Spec.pdf?v=1610036163\" target=\"_blank\" title=\"AEMC 205 True RMS Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 205 True RMS Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 205 True RMS Clamp Meter with Phase Rotation, 600AAC/900ADC

AEMC 205 True RMS Clamp Meter with Phase Rotation, 600AAC/900ADC

$553.00 CAD

The True RMS Clamp-On Meter Model 205 is safety rated at 600V CAT IV. It measures AC+DC volts and amps, frequency, continuity, resistance, power and Power Factor, phase rotation, and THD. It can also perform diode checks. The Delta relative function compares new measurements to a reference value, and the MIN/MAX function tracks high and low valu...


More Info
{"id":6179504160958,"title":"AEMC 603 True RMS Clamp Meter with Temperature, 2000A AC\/3000A DC","handle":"aemc-603-true-rms-clamp-meter-with-temperature-2000a-ac-3000a-dc","description":"\u003cp\u003e\u003cspan\u003eThe TRMS Clamp-on Meter Model 603 provides a new standard for safety and measurement capability not available in any other clamp meter sold today. Safety Rated at 1000V CAT IV, it is safe to operate in all electrical environments. It is rugged enough for the most demanding work environments and will withstand both dust and water spray with its IP54 rating. It is ergonomically designed and easily used by one hand, including function selection and button pushing even with a glove on. In addition to the standard measurement of volts, amps, frequency, resistance, diode checking and continuity, the Model 603 offers several unequaled functions including: \u003c\/span\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.aemc.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/www.aemc.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003e\u003csup\u003e®\u003c\/sup\u003e\u003c\/a\u003e\u003cspan\u003e, Adapter function, Delta relative function, temperature measurement, and more.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1000V CAT IV Rated\u003c\/li\u003e\n\u003cli\u003eUL 94 flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003eIP54 Rated\u003c\/li\u003e\n\u003cli\u003e10,000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1000VDC and AC and DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 2000AAC and 3000ADC\u003c\/li\u003e\n\u003cli\u003eMeasures temperature in °F or °C using a K-type Thermocouple\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC measurement voltage\u003c\/li\u003e\n\u003cli\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ecurrent measurement with 1mS capture\u003c\/li\u003e\n\u003cli\u003eDelta relative function for tracking deviation from reference values\u003c\/li\u003e\n\u003cli\u003eAdapter function to accept inputs from sensors and transducers with a millivolt output with user programmable scaling\u003c\/li\u003e\n\u003cli\u003eJaw opening up to 2.36\"\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Vrms AC\/DC Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2000Arms AC, 3000ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts, 5% ± 5cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eInRush:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e10 to 1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eSelectable from 0 to 999.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e100kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDiode Test:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0 to 3.2VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e20kHz in V, 2kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTemperature K Thermocouple:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-76.0 to 2192°F (-60 to 1200°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAdapter Function:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eMIN\/MAX:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003e∆REL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e4 x AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e\u0026gt;350 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e11.65 x 4.37 x 1.61\" (296 x 111 x 41mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.4 lbs (640g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2.36\" (60mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-4° to +131°F (-20° to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-40° to +158°F (-40° to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN\/IEC 61010-1 to 1000V CAT IV\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Clamp-On Meter with Temperature\u003c\/li\u003e\n\u003cli\u003eSilicone Color Coded Insulated Test Leads\u003c\/li\u003e\n\u003cli\u003eTest Probes\u003c\/li\u003e\n\u003cli\u003eAlligator Clips\u003c\/li\u003e\n\u003cli\u003eK-Thermocouple with 4mm Integrated Adapter\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003cli\u003e4 x AA Batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_200-400-600_Series_Clamps_-_High_Current_Spec.pdf?v=1610036163\" target=\"_blank\" title=\"AEMC 603 True RMS Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 603 True RMS Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-18T10:53:06-07:00","created_at":"2021-01-18T10:53:05-07:00","vendor":"AEMC Instruments","type":"Clamp Meters","tags":[],"price":59400,"price_min":59400,"price_max":59400,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37911341269182,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2139.31","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 603 True RMS Clamp Meter with Temperature, 2000A AC\/3000A DC","public_title":null,"options":["Default Title"],"price":59400,"weight":4082,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338110272","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC603Pic1.png?v=1610992388"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC603Pic1.png?v=1610992388","options":["Title"],"media":[{"alt":null,"id":15454533583038,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC603Pic1.png?v=1610992388"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC603Pic1.png?v=1610992388","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe TRMS Clamp-on Meter Model 603 provides a new standard for safety and measurement capability not available in any other clamp meter sold today. Safety Rated at 1000V CAT IV, it is safe to operate in all electrical environments. It is rugged enough for the most demanding work environments and will withstand both dust and water spray with its IP54 rating. It is ergonomically designed and easily used by one hand, including function selection and button pushing even with a glove on. In addition to the standard measurement of volts, amps, frequency, resistance, diode checking and continuity, the Model 603 offers several unequaled functions including: \u003c\/span\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.aemc.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003ca href=\"https:\/\/www.aemc.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003e\u003csup\u003e®\u003c\/sup\u003e\u003c\/a\u003e\u003cspan\u003e, Adapter function, Delta relative function, temperature measurement, and more.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1000V CAT IV Rated\u003c\/li\u003e\n\u003cli\u003eUL 94 flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003eIP54 Rated\u003c\/li\u003e\n\u003cli\u003e10,000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1000VDC and AC and DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 2000AAC and 3000ADC\u003c\/li\u003e\n\u003cli\u003eMeasures temperature in °F or °C using a K-type Thermocouple\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC measurement voltage\u003c\/li\u003e\n\u003cli\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ecurrent measurement with 1mS capture\u003c\/li\u003e\n\u003cli\u003eDelta relative function for tracking deviation from reference values\u003c\/li\u003e\n\u003cli\u003eAdapter function to accept inputs from sensors and transducers with a millivolt output with user programmable scaling\u003c\/li\u003e\n\u003cli\u003eJaw opening up to 2.36\"\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Vrms AC\/DC Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2000Arms AC, 3000ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts, 5% ± 5cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eInRush:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e10 to 1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eSelectable from 0 to 999.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e100kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDiode Test:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0 to 3.2VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e20kHz in V, 2kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTemperature K Thermocouple:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-76.0 to 2192°F (-60 to 1200°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAdapter Function:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eMIN\/MAX:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003e∆REL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e4 x AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e\u0026gt;350 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e11.65 x 4.37 x 1.61\" (296 x 111 x 41mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.4 lbs (640g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2.36\" (60mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-4° to +131°F (-20° to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-40° to +158°F (-40° to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN\/IEC 61010-1 to 1000V CAT IV\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Clamp-On Meter with Temperature\u003c\/li\u003e\n\u003cli\u003eSilicone Color Coded Insulated Test Leads\u003c\/li\u003e\n\u003cli\u003eTest Probes\u003c\/li\u003e\n\u003cli\u003eAlligator Clips\u003c\/li\u003e\n\u003cli\u003eK-Thermocouple with 4mm Integrated Adapter\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003cli\u003e4 x AA Batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_200-400-600_Series_Clamps_-_High_Current_Spec.pdf?v=1610036163\" target=\"_blank\" title=\"AEMC 603 True RMS Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 603 True RMS Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 603 True RMS Clamp Meter with Temperature, 2000A AC/3000A DC

AEMC 603 True RMS Clamp Meter with Temperature, 2000A AC/3000A DC

$594.00 CAD

The TRMS Clamp-on Meter Model 603 provides a new standard for safety and measurement capability not available in any other clamp meter sold today. Safety Rated at 1000V CAT IV, it is safe to operate in all electrical environments. It is rugged enough for the most demanding work environments and will withstand both dust and water spray with its I...


More Info
{"id":6179495084222,"title":"AEMC 403 True RMS Clamp Meter with Temperature, 1000A AC\/1500A DC","handle":"aemc-403-true-rms-clamp-meter-with-temperature-1000a-ac-1500a-dc","description":"\u003cp\u003e\u003cspan\u003eThe True RMS Clamp-On Meter Model 403 is safety rated at 1000V CAT IV. It measures voltage, current, resistance, frequency, \u003c\/span\u003e\u003ca href=\"http:\/\/www.aemc.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003e\u003cstrong\u003e\u003cspan color=\"#004f92\" style=\"color: #004f92;\"\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003cspan\u003e\u003csup\u003e®\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003etemperature, and continuity. It can also perform diode checks. Adapter mode allows external sensor inputs to be displayed. Delta relative function allows new measurements to be compared to a reference value. This rugged meter can operate in demanding work environments, and its IP54 rating allows it to withstand both dust and water spray.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1000V CAT IV Rated\u003c\/li\u003e\n\u003cli\u003eUL 94 flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003eIP54 Rated\u003c\/li\u003e\n\u003cli\u003e10,000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1000VDC and AC and DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000AAC and 2000ADC\u003c\/li\u003e\n\u003cli\u003eMeasures temperature in °F or °C using a K-type Thermocouple\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC measurement voltage\u003c\/li\u003e\n\u003cli\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ecurrent measurement with 1mS capture\u003c\/li\u003e\n\u003cli\u003eDelta relative function for tracking deviation from reference values\u003c\/li\u003e\n\u003cli\u003eAdapter function to accept inputs from sensors and transducers with a millivolt output with user programmable scaling\u003c\/li\u003e\n\u003cli\u003eJaw opening up to 1.89\"\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1000Vrms AC\/DC Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1000Arms AC, 1500ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eInRush:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e10 to 1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eSelectable from 0 to 999.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e100kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eDiode Test:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e0 to 3.2VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e20kHz in V, 2kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eTemperature K Thermocouple:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e-76.0 to 2192°F (-60 to 1200°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eAdapter Function:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eLCD w\/backlight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eMIN\/MAX:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e4 x AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e\u0026gt;350 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e10.7 x 3.6 x 1.6\" (272 x 92 x 41mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1.32 lbs (600g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1.89\" (48mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e-4° to +131°F (-20° to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e-40° to +158°F (-40° to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eEN\/IEC 61010-1 to 1000V CAT IV\u003cimg src=\"https:\/\/www.aemc.com\/userfiles\/images\/logos\/CE_Logo.png\" alt=\"\"\u003e\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Clamp-on Meter\u003c\/li\u003e\n\u003cli\u003e2152.03 Silicone Lead Set, 1000V, CAT IV Rated\u003c\/li\u003e\n\u003cli\u003e2139.71 Type K Thermocouple\u003c\/li\u003e\n\u003cli\u003e2139.72 Soft Carrying Case\u003c\/li\u003e\n\u003cli\u003e4 x AA 1.2V Batteries\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_200-400-600_Series_Clamps_-_High_Current_Spec.pdf?v=1610036163\" target=\"_blank\" title=\"AEMC 403 True RMS Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 403 True RMS Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-18T10:47:38-07:00","created_at":"2021-01-18T10:47:37-07:00","vendor":"AEMC Instruments","type":"Clamp Meters","tags":[],"price":56700,"price_min":56700,"price_max":56700,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37911301030078,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2139.21","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 403 True RMS Clamp Meter with Temperature, 1000A AC\/1500A DC","public_title":null,"options":["Default Title"],"price":56700,"weight":4082,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338110258","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC403Pic1.png?v=1610992059"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC403Pic1.png?v=1610992059","options":["Title"],"media":[{"alt":null,"id":15454500323518,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC403Pic1.png?v=1610992059"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC403Pic1.png?v=1610992059","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe True RMS Clamp-On Meter Model 403 is safety rated at 1000V CAT IV. It measures voltage, current, resistance, frequency, \u003c\/span\u003e\u003ca href=\"http:\/\/www.aemc.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003e\u003cstrong\u003e\u003cspan color=\"#004f92\" style=\"color: #004f92;\"\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003cspan\u003e\u003csup\u003e®\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003etemperature, and continuity. It can also perform diode checks. Adapter mode allows external sensor inputs to be displayed. Delta relative function allows new measurements to be compared to a reference value. This rugged meter can operate in demanding work environments, and its IP54 rating allows it to withstand both dust and water spray.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1000V CAT IV Rated\u003c\/li\u003e\n\u003cli\u003eUL 94 flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003eIP54 Rated\u003c\/li\u003e\n\u003cli\u003e10,000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1000VDC and AC and DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000AAC and 2000ADC\u003c\/li\u003e\n\u003cli\u003eMeasures temperature in °F or °C using a K-type Thermocouple\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC measurement voltage\u003c\/li\u003e\n\u003cli\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003ecurrent measurement with 1mS capture\u003c\/li\u003e\n\u003cli\u003eDelta relative function for tracking deviation from reference values\u003c\/li\u003e\n\u003cli\u003eAdapter function to accept inputs from sensors and transducers with a millivolt output with user programmable scaling\u003c\/li\u003e\n\u003cli\u003eJaw opening up to 1.89\"\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1000Vrms AC\/DC Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1000Arms AC, 1500ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eInRush:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e10 to 1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eSelectable from 0 to 999.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e100kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eDiode Test:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e0 to 3.2VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e20kHz in V, 2kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eTemperature K Thermocouple:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e-76.0 to 2192°F (-60 to 1200°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eAdapter Function:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eLCD w\/backlight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eMIN\/MAX:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e4 x AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e\u0026gt;350 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e10.7 x 3.6 x 1.6\" (272 x 92 x 41mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1.32 lbs (600g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1.89\" (48mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e-4° to +131°F (-20° to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e-40° to +158°F (-40° to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eEN\/IEC 61010-1 to 1000V CAT IV\u003cimg src=\"https:\/\/www.aemc.com\/userfiles\/images\/logos\/CE_Logo.png\" alt=\"\"\u003e\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Clamp-on Meter\u003c\/li\u003e\n\u003cli\u003e2152.03 Silicone Lead Set, 1000V, CAT IV Rated\u003c\/li\u003e\n\u003cli\u003e2139.71 Type K Thermocouple\u003c\/li\u003e\n\u003cli\u003e2139.72 Soft Carrying Case\u003c\/li\u003e\n\u003cli\u003e4 x AA 1.2V Batteries\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_200-400-600_Series_Clamps_-_High_Current_Spec.pdf?v=1610036163\" target=\"_blank\" title=\"AEMC 403 True RMS Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 403 True RMS Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 403 True RMS Clamp Meter with Temperature, 1000A AC/1500A DC

AEMC 403 True RMS Clamp Meter with Temperature, 1000A AC/1500A DC

$567.00 CAD

The True RMS Clamp-On Meter Model 403 is safety rated at 1000V CAT IV. It measures voltage, current, resistance, frequency, True InRush®, temperature, and continuity. It can also perform diode checks. Adapter mode allows external sensor inputs to be displayed. Delta relative function allows new measurements to be compared to a reference value. T...


More Info
{"id":6173063971006,"title":"AEMC 203 True RMS Clamp Meter with Temperature, 600AAC\/900ADC","handle":"aemc-203-true-rms-clamp-meter-with-temperature-600aac-900adc","description":"\u003cp\u003e\u003cspan\u003eThe True RMS Clamp-On Meter Model 203 is safety rated at 600V CAT IV. It measures AC+DC volts and amps, frequency, continuity, resistance, and temperature (with the supplied K thermocouple probe). The Model 203 can also perform diode checks. Its Adapter mode displays external sensor inputs. The Delta relative function compares new measurements to a reference value, and the MIN\/MAX function tracks high and low values. This compact and rugged meter can operate in demanding work environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUL94 VI flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003e6000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1400VDC and AC+DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 600AAC and 900ADC\u003c\/li\u003e\n\u003cli\u003eMeasures single- and three-phase power (real, reactive, and apparent) up to 600kW with resolution to 1W\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue InRush® current measurement with 1ms capture\u003c\/li\u003e\n\u003cli\u003eJaw opening to 1.33\" (34mm); IP54 Rated\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Vrms AC\/DC Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e600Arms AC, 900ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eInRush:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e6 to 600AAC, 6 to 900ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eSelectable from 0 to 599.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e60kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDiode Test:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0 to 3.2VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e20kHz in V, 3kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTemperature K Thermocouple:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-76.0 to 2192°F (-60 to 1200°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAdapter Function:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eMIN\/MAX:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1 x 9V, IEC LF22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e\u0026gt;130 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e8.7 x 3.1 x 1.65\" (222 x 78 x 42mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e12.0 oz. (340g) with battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.34\" (34mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-4° to +131°F (-20 to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-40° to +158°F (-40 to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN\/IEC 61010-1: 1000V CAT III, 600V CAT IV\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAEMC 203 True RMS Clamp Meter with Temperature, 600AAC\/900ADC\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_200-400-600_Series_Clamps_-_High_Current_Spec.pdf?v=1610036163\" target=\"_blank\" title=\"AEMC 203 True RMS Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 203 True RMS Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-14T13:38:48-07:00","created_at":"2021-01-14T13:38:46-07:00","vendor":"AEMC Instruments","type":"Clamp Meters","tags":[],"price":32300,"price_min":32300,"price_max":32300,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37889858306238,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2139.12","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 203 True RMS Clamp Meter with Temperature, 600AAC\/900ADC","public_title":null,"options":["Default Title"],"price":32300,"weight":4082,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338110234","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC203Pic1.png?v=1610656729"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC203Pic1.png?v=1610656729","options":["Title"],"media":[{"alt":null,"id":15426189000894,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC203Pic1.png?v=1610656729"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC203Pic1.png?v=1610656729","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe True RMS Clamp-On Meter Model 203 is safety rated at 600V CAT IV. It measures AC+DC volts and amps, frequency, continuity, resistance, and temperature (with the supplied K thermocouple probe). The Model 203 can also perform diode checks. Its Adapter mode displays external sensor inputs. The Delta relative function compares new measurements to a reference value, and the MIN\/MAX function tracks high and low values. This compact and rugged meter can operate in demanding work environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUL94 VI flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003e6000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1400VDC and AC+DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 600AAC and 900ADC\u003c\/li\u003e\n\u003cli\u003eMeasures single- and three-phase power (real, reactive, and apparent) up to 600kW with resolution to 1W\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue InRush® current measurement with 1ms capture\u003c\/li\u003e\n\u003cli\u003eJaw opening to 1.33\" (34mm); IP54 Rated\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Vrms AC\/DC Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e600Arms AC, 900ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eInRush:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e6 to 600AAC, 6 to 900ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eSelectable from 0 to 599.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e60kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDiode Test:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0 to 3.2VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e20kHz in V, 3kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTemperature K Thermocouple:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-76.0 to 2192°F (-60 to 1200°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAdapter Function:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eMIN\/MAX:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1 x 9V, IEC LF22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e\u0026gt;130 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e8.7 x 3.1 x 1.65\" (222 x 78 x 42mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e12.0 oz. (340g) with battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.34\" (34mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-4° to +131°F (-20 to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-40° to +158°F (-40 to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN\/IEC 61010-1: 1000V CAT III, 600V CAT IV\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAEMC 203 True RMS Clamp Meter with Temperature, 600AAC\/900ADC\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_200-400-600_Series_Clamps_-_High_Current_Spec.pdf?v=1610036163\" target=\"_blank\" title=\"AEMC 203 True RMS Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 203 True RMS Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 203 True RMS Clamp Meter with Temperature, 600AAC/900ADC

AEMC 203 True RMS Clamp Meter with Temperature, 600AAC/900ADC

$323.00 CAD

The True RMS Clamp-On Meter Model 203 is safety rated at 600V CAT IV. It measures AC+DC volts and amps, frequency, continuity, resistance, and temperature (with the supplied K thermocouple probe). The Model 203 can also perform diode checks. Its Adapter mode displays external sensor inputs. The Delta relative function compares new measurements t...


More Info
AEMC CM605 Clamp Meter, 100A

Clamp Meters

$293.00 CAD
{"id":6156255101118,"title":"AEMC CM605 Clamp Meter, 100A","handle":"aemc-cm605-clamp-meter-100a","description":"\u003cp\u003e\u003cspan\u003eThe Multifunction Clamp-on Meter Model CM605 is an ideal choice for both process and general industrial markets. It is also the perfect instrument for measuring 4 to 20mA process signals, as well as the higher currents up to 100A associated with general industrial monitoring and troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe Model CM605 is a versatile device that is capable of measuring both AC\/DC voltage (up to 600V) and AC\/DC current. It can also measure resistance up to 10kΩ and includes a continuity buzzer to assist in circuit verification.\u003c\/p\u003e\n\u003cp\u003eFor operator convenience, the Model CM605 can also hold the last reading in the display and capture the peak value at the time of the measurement.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e10,000-count LCD display - excellent resolution\u003c\/li\u003e\n\u003cli\u003e100A AC\/DC Ammeter with low 10A range (1mA resolution)\u003c\/li\u003e\n\u003cli\u003eTapered jaws for crowded wiring areas (Ø.60\"- 15mm Jaw opening) (Ø.45\"- 12mm Cable diameter)\u003c\/li\u003e\n\u003cli\u003e600V AC\/DC voltmeter\u003c\/li\u003e\n\u003cli\u003eAnalog output in A AC\/DC to data loggers, etc\u003c\/li\u003e\n\u003cli\u003eAuto-ranging \u0026amp; A DC zero push-button\u003c\/li\u003e\n\u003cli\u003eData HOLD \u0026amp; PEAK functions\u003c\/li\u003e\n\u003cli\u003eRelative function to compare two measurements\u003c\/li\u003e\n\u003cli\u003eOhm range \u0026amp; continuity test with beeper\u003c\/li\u003e\n\u003cli\u003eAUTO-OFF and low battery indicator\u003c\/li\u003e\n\u003cli\u003eIEC\/EN 61010 safety rated \u0026amp; CE mark\u003c\/li\u003e\n\u003cli\u003e600Vrms overload protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e600V AC\/DC Auto-Ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e100A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.001A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.5% ± 5cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2% ± 10cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e\u0026lt;100Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e10kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003e∆REL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2 x AAA, IEC LR03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e7.44 x 2.8 x 1.46\" (189 x 71 x 37mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e6.5 oz. (180g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.45\" (12mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e+32° to 104°F (0 to +40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e+14° to 140°F (-10 to +60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e80% up to 104°F (40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN\/IEC 61010 to 300V CAT III, 600V CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span10\"\u003e\n\u003cdiv class=\"mhide ipad-view-setting\"\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"row-fluid ProductTabs\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv id=\"tab2\" class=\"product-tabs tab-pane active\"\u003e\n\u003cul\u003e\n\u003cli\u003eCM605 Clamp Meter\u003c\/li\u003e\n\u003cli\u003eRed and black lead set with needle point test probes\u003c\/li\u003e\n\u003cli\u003eCarrying case\u003c\/li\u003e\n\u003cli\u003e2 x 1.5V AAA batteries\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row-fluid\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"span2 mhide ipad-view-setting\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_CM605_clamp-on-meter-specs-7000-02.pdf?v=1609972128\" target=\"_blank\" title=\"AEMC CM605 Clamp Meter Specs\" rel=\"noopener noreferrer\"\u003eAEMC CM605 Clamp Meter Specs\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-06T15:39:29-07:00","created_at":"2021-01-06T15:39:28-07:00","vendor":"AEMC Instruments","type":"Clamp Meters","tags":[],"price":29300,"price_min":29300,"price_max":29300,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37840204562622,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-7000.02","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC CM605 Clamp Meter, 100A","public_title":null,"options":["Default Title"],"price":29300,"weight":2722,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338110203","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCCM605Pic1.png?v=1609972771"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCCM605Pic1.png?v=1609972771","options":["Title"],"media":[{"alt":null,"id":15349877833918,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCCM605Pic1.png?v=1609972771"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCCM605Pic1.png?v=1609972771","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Multifunction Clamp-on Meter Model CM605 is an ideal choice for both process and general industrial markets. It is also the perfect instrument for measuring 4 to 20mA process signals, as well as the higher currents up to 100A associated with general industrial monitoring and troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe Model CM605 is a versatile device that is capable of measuring both AC\/DC voltage (up to 600V) and AC\/DC current. It can also measure resistance up to 10kΩ and includes a continuity buzzer to assist in circuit verification.\u003c\/p\u003e\n\u003cp\u003eFor operator convenience, the Model CM605 can also hold the last reading in the display and capture the peak value at the time of the measurement.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e10,000-count LCD display - excellent resolution\u003c\/li\u003e\n\u003cli\u003e100A AC\/DC Ammeter with low 10A range (1mA resolution)\u003c\/li\u003e\n\u003cli\u003eTapered jaws for crowded wiring areas (Ø.60\"- 15mm Jaw opening) (Ø.45\"- 12mm Cable diameter)\u003c\/li\u003e\n\u003cli\u003e600V AC\/DC voltmeter\u003c\/li\u003e\n\u003cli\u003eAnalog output in A AC\/DC to data loggers, etc\u003c\/li\u003e\n\u003cli\u003eAuto-ranging \u0026amp; A DC zero push-button\u003c\/li\u003e\n\u003cli\u003eData HOLD \u0026amp; PEAK functions\u003c\/li\u003e\n\u003cli\u003eRelative function to compare two measurements\u003c\/li\u003e\n\u003cli\u003eOhm range \u0026amp; continuity test with beeper\u003c\/li\u003e\n\u003cli\u003eAUTO-OFF and low battery indicator\u003c\/li\u003e\n\u003cli\u003eIEC\/EN 61010 safety rated \u0026amp; CE mark\u003c\/li\u003e\n\u003cli\u003e600Vrms overload protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e600V AC\/DC Auto-Ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e100A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.001A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.5% ± 5cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2% ± 10cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e\u0026lt;100Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e10kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003e∆REL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2 x AAA, IEC LR03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e7.44 x 2.8 x 1.46\" (189 x 71 x 37mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e6.5 oz. (180g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.45\" (12mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e+32° to 104°F (0 to +40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e+14° to 140°F (-10 to +60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e80% up to 104°F (40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN\/IEC 61010 to 300V CAT III, 600V CAT II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span10\"\u003e\n\u003cdiv class=\"mhide ipad-view-setting\"\u003e\n\u003cdiv class=\"row-fluid\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"row-fluid ProductTabs\"\u003e\n\u003cdiv class=\"span12\"\u003e\n\u003cdiv class=\"tab-content\"\u003e\n\u003cdiv id=\"tab2\" class=\"product-tabs tab-pane active\"\u003e\n\u003cul\u003e\n\u003cli\u003eCM605 Clamp Meter\u003c\/li\u003e\n\u003cli\u003eRed and black lead set with needle point test probes\u003c\/li\u003e\n\u003cli\u003eCarrying case\u003c\/li\u003e\n\u003cli\u003e2 x 1.5V AAA batteries\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row-fluid\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"span2 mhide ipad-view-setting\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_CM605_clamp-on-meter-specs-7000-02.pdf?v=1609972128\" target=\"_blank\" title=\"AEMC CM605 Clamp Meter Specs\" rel=\"noopener noreferrer\"\u003eAEMC CM605 Clamp Meter Specs\u003c\/a\u003e\u003c\/p\u003e"}
AEMC CM605 Clamp Meter, 100A

AEMC CM605 Clamp Meter, 100A

$293.00 CAD

The Multifunction Clamp-on Meter Model CM605 is an ideal choice for both process and general industrial markets. It is also the perfect instrument for measuring 4 to 20mA process signals, as well as the higher currents up to 100A associated with general industrial monitoring and troubleshooting. The Model CM605 is a versatile device that is capa...


More Info
{"id":6156072911038,"title":"AEMC 565 True RMS Clamp-on Leakage Current Meter, 60mA-100A, 600V AC\/DC","handle":"aemc-565-true-rms-clamp-on-leakage-current-meter-60ma-100a-600v-ac-dc","description":"\u003cp\u003e\u003cspan\u003eThe TRMS Clamp-On Leakage Current Meter Model 565 is designed to measure low AC currents, which are typically leakage currents in ground conductors. Low currents are measured using either the 60mA or the 600mA range. The high sensitivity of the probe (10µA and 100µA) is possible through special jaw construction and, in particular, critical shielding of the jaws. At low measurement levels, this shielding out of the noise is critical for low sensitivity, accuracy, and stability.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThe Model 565 can be used as a standard clamp-on meter measuring to 100Arms, as well as AC and DC voltage, resistance and continuity with a buzzer.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThe Model 565 is ergonomic in design and fits well in the hand, facilitating one hand operation. The jaw size is compact yet designed to accommodate the most common conductors up to 1\" (26mm) in diameter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCheck for leakage and locate insulation breakdowns on live circuits.\u003c\/li\u003e\n\u003cli\u003eMeasures leakage current up to 600mA with up to 10μA resolution.\u003c\/li\u003e\n\u003cli\u003eMeasures current up to 100Arms\u003c\/li\u003e\n\u003cli\u003eMeasures up to 600Vac\/dc\u003c\/li\u003e\n\u003cli\u003eMeasures Hz on either V or A inputs\u003c\/li\u003e\n\u003cli\u003eMeasures Resistance and Continuity\u003c\/li\u003e\n\u003cli\u003eHold feature freezes Value\u003c\/li\u003e\n\u003cli\u003eMax feature keeps track of highest measured In-rush value\u003c\/li\u003e\n\u003cli\u003eZero button ideal for measuring relative values\u003c\/li\u003e\n\u003cli\u003eFilter to isolate 50\/60Hz fundamental from harmonics\u003c\/li\u003e\n\u003cli\u003eCompatible with VDE 0404\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e600Vrms AC\/DC Auto-Ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e0.1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e100Arms AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e10µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1.0% ± 5cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1.2% ± 5cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e\u0026lt;35Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1kHz in V, A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003e∆REL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e2 x AAA, IEC LR03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e45 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e8.5 x 2.5 x 1.18\" (218 x 64 x 30mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e10.0 oz. (280g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1.10\" (28mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e+32° to 104°F (0° to +40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e+14° to 140°F (-10° to +60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e80% up to 104°F (40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eEN\/IEC 61010 to 600V CAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Clamp-on Leakage Current Meter\u003c\/li\u003e\n\u003cli\u003eTwo color-coded 5ft test leads\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003cli\u003e2 AAA Batteries\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_565_Leakage_Current_Meter_-_2117-56.pdf?v=1609963943\" target=\"_blank\" title=\"AEMC 565 Clamp-on Leakage Current Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 565 Clamp-on Leakage Current Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-06T13:14:09-07:00","created_at":"2021-01-06T13:14:08-07:00","vendor":"AEMC Instruments","type":"Clamp Meters","tags":[],"price":38500,"price_min":38500,"price_max":38500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37839438610622,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2117.56","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 565 True RMS Clamp-on Leakage Current Meter, 60mA-100A, 600V AC\/DC","public_title":null,"options":["Default Title"],"price":38500,"weight":2722,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338110166","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC565Pic1.png?v=1609964051"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC565Pic1.png?v=1609964051","options":["Title"],"media":[{"alt":null,"id":15349162213566,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC565Pic1.png?v=1609964051"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC565Pic1.png?v=1609964051","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe TRMS Clamp-On Leakage Current Meter Model 565 is designed to measure low AC currents, which are typically leakage currents in ground conductors. Low currents are measured using either the 60mA or the 600mA range. The high sensitivity of the probe (10µA and 100µA) is possible through special jaw construction and, in particular, critical shielding of the jaws. At low measurement levels, this shielding out of the noise is critical for low sensitivity, accuracy, and stability.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThe Model 565 can be used as a standard clamp-on meter measuring to 100Arms, as well as AC and DC voltage, resistance and continuity with a buzzer.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eThe Model 565 is ergonomic in design and fits well in the hand, facilitating one hand operation. The jaw size is compact yet designed to accommodate the most common conductors up to 1\" (26mm) in diameter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCheck for leakage and locate insulation breakdowns on live circuits.\u003c\/li\u003e\n\u003cli\u003eMeasures leakage current up to 600mA with up to 10μA resolution.\u003c\/li\u003e\n\u003cli\u003eMeasures current up to 100Arms\u003c\/li\u003e\n\u003cli\u003eMeasures up to 600Vac\/dc\u003c\/li\u003e\n\u003cli\u003eMeasures Hz on either V or A inputs\u003c\/li\u003e\n\u003cli\u003eMeasures Resistance and Continuity\u003c\/li\u003e\n\u003cli\u003eHold feature freezes Value\u003c\/li\u003e\n\u003cli\u003eMax feature keeps track of highest measured In-rush value\u003c\/li\u003e\n\u003cli\u003eZero button ideal for measuring relative values\u003c\/li\u003e\n\u003cli\u003eFilter to isolate 50\/60Hz fundamental from harmonics\u003c\/li\u003e\n\u003cli\u003eCompatible with VDE 0404\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e600Vrms AC\/DC Auto-Ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e0.1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e100Arms AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e10µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1.0% ± 5cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1.2% ± 5cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e\u0026lt;35Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1kHz in V, A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003e∆REL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e2 x AAA, IEC LR03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e45 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e8.5 x 2.5 x 1.18\" (218 x 64 x 30mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e10.0 oz. (280g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e1.10\" (28mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e+32° to 104°F (0° to +40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e+14° to 140°F (-10° to +60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e80% up to 104°F (40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"22%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"78%\"\u003eEN\/IEC 61010 to 600V CAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Clamp-on Leakage Current Meter\u003c\/li\u003e\n\u003cli\u003eTwo color-coded 5ft test leads\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003cli\u003e2 AAA Batteries\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_565_Leakage_Current_Meter_-_2117-56.pdf?v=1609963943\" target=\"_blank\" title=\"AEMC 565 Clamp-on Leakage Current Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 565 Clamp-on Leakage Current Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 565 True RMS Clamp-on Leakage Current Meter, 60mA-100A, 600V AC/DC

AEMC 565 True RMS Clamp-on Leakage Current Meter, 60mA-100A, 600V AC/DC

$385.00 CAD

The TRMS Clamp-On Leakage Current Meter Model 565 is designed to measure low AC currents, which are typically leakage currents in ground conductors. Low currents are measured using either the 60mA or the 600mA range. The high sensitivity of the probe (10µA and 100µA) is possible through special jaw construction and, in particular, critical shiel...


More Info
{"id":6155966972094,"title":"AEMC 607 Power Clamp Meter\/Data Logger, 1000 V AC\/DC, 2000 A AC\/3000 A DC","handle":"aemc-607-power-clamp-meter-data-logger-1000-v-ac-dc-2000-a-ac-3000-a-dc","description":"\u003cp\u003e\u003cspan\u003eThe TRMS Power Clamp-on Meter Model 607 provides a new standard for safety and measurement capability not available in any other clamp meter sold today. Safety Rated at 1000V CAT IV, it is safe to operate in most electrical environments. It is rugged enough for the most demanding work environments and will withstand both dust and water spray with its IP54 rating. It is ergonomically designed and easily used by one hand, including function selection and button pushing even with a glove on. In addition to the standard measurement of volts, amps, frequency, resistance, diode checking and continuity, the Model 607 offers several unequaled functions including: AC, DC and AC+DC volts, amps and power,\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.aemc.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003csup\u003e®\u003c\/sup\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cspan\u003e, power measurements, harmonic analysis, data logging, and more.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1000V CAT IV Rated\u003c\/li\u003e\n\u003cli\u003eUL 94 flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003eIP54 Rated\u003c\/li\u003e\n\u003cli\u003e10,000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000V AC (1400V peak), 1000V DC and AC+DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000A AC and 2000A DC\u003c\/li\u003e\n\u003cli\u003eMeasures single- and three-phase power (real, reactive and apparent) up to 3MW with resolution to 1W\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC measurement voltage\u003c\/li\u003e\n\u003cli\u003eTrue\u003cem\u003e\u003cspan\u003e \u003c\/span\u003eInRush\u003c\/em\u003e\u003cem\u003e™\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003ecurrent measurement with 1mS capture\u003c\/li\u003e\n\u003cli\u003eRecords up to 1000 measurements\u003c\/li\u003e\n\u003cli\u003eWireless Bluetooth communications\u003c\/li\u003e\n\u003cli\u003eJaw opening up to 1.89\"\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Vrms AC\/DC\/AC+DC Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2000Arms AC, 3000ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTrue InRush®:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e20 to 2000AAC, 20 to 3000ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Measurement Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2MW AC, 3MW DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eHarmonics:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eUp to 25th\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTHD:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes, %f and %r\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eSelectable from 0 to 999.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e100kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e20kHz in V, 2kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Factor:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePhase Order:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eMIN\/MAX\/PEAK-\/PEAK+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003e∆REL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eRecording:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes, up to 1000 points (160 hours at 10 min intervals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eBluetooth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSoftware:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes, DataView included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e4 x AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e\u0026gt;350 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e10.7 x 3.6 x 1.6\" (272 x 92 x 41mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.4 lbs (640g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2.36\" (60mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-4° to +131°F (-20 to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-40° to +158°F (-40 to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN\/IEC 61010-1 to 1000V CAT IV\u003cimg src=\"https:\/\/www.aemc.com\/userfiles\/images\/logos\/CE_Logo.png\" alt=\"\"\u003e\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Power Clamp-on Meter with Phase Rotation\u003c\/li\u003e\n\u003cli\u003eSet of two color coded silicone insulated test leads\u003c\/li\u003e\n\u003cli\u003eTest probes and alligator clips\u003c\/li\u003e\n\u003cli\u003eHard carrying case\u003c\/li\u003e\n\u003cli\u003eFour AA Batteries\u003c\/li\u003e\n\u003cli\u003eSafety Information sheet\u003c\/li\u003e\n\u003cli\u003eDataView Software\u003c\/li\u003e\n\u003cli\u003eBluetooth adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_407-607_Clamp_Meter_-_2139-61.pdf?v=1609958892\" target=\"_blank\" title=\"AEMC 607 Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 607 Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-06T11:55:43-07:00","created_at":"2021-01-06T11:55:43-07:00","vendor":"AEMC Instruments","type":"Clamp Meters","tags":[],"price":93800,"price_min":93800,"price_max":93800,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37839194030270,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2139.61","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 607 Power Clamp Meter\/Data Logger, 1000 V AC\/DC, 2000 A AC\/3000 A DC","public_title":null,"options":["Default Title"],"price":93800,"weight":4082,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338220445","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC607Pic1.png?v=1609959344"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC607Pic1.png?v=1609959344","options":["Title"],"media":[{"alt":null,"id":15348835647678,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC607Pic1.png?v=1609959344"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC607Pic1.png?v=1609959344","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe TRMS Power Clamp-on Meter Model 607 provides a new standard for safety and measurement capability not available in any other clamp meter sold today. Safety Rated at 1000V CAT IV, it is safe to operate in most electrical environments. It is rugged enough for the most demanding work environments and will withstand both dust and water spray with its IP54 rating. It is ergonomically designed and easily used by one hand, including function selection and button pushing even with a glove on. In addition to the standard measurement of volts, amps, frequency, resistance, diode checking and continuity, the Model 607 offers several unequaled functions including: AC, DC and AC+DC volts, amps and power,\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.aemc.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003csup\u003e®\u003c\/sup\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cspan\u003e, power measurements, harmonic analysis, data logging, and more.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1000V CAT IV Rated\u003c\/li\u003e\n\u003cli\u003eUL 94 flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003eIP54 Rated\u003c\/li\u003e\n\u003cli\u003e10,000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000V AC (1400V peak), 1000V DC and AC+DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000A AC and 2000A DC\u003c\/li\u003e\n\u003cli\u003eMeasures single- and three-phase power (real, reactive and apparent) up to 3MW with resolution to 1W\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC measurement voltage\u003c\/li\u003e\n\u003cli\u003eTrue\u003cem\u003e\u003cspan\u003e \u003c\/span\u003eInRush\u003c\/em\u003e\u003cem\u003e™\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003ecurrent measurement with 1mS capture\u003c\/li\u003e\n\u003cli\u003eRecords up to 1000 measurements\u003c\/li\u003e\n\u003cli\u003eWireless Bluetooth communications\u003c\/li\u003e\n\u003cli\u003eJaw opening up to 1.89\"\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Vrms AC\/DC\/AC+DC Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2000Arms AC, 3000ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTrue InRush®:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e20 to 2000AAC, 20 to 3000ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Measurement Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2MW AC, 3MW DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eHarmonics:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eUp to 25th\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTHD:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes, %f and %r\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eSelectable from 0 to 999.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e100kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e20kHz in V, 2kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Factor:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePhase Order:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eMIN\/MAX\/PEAK-\/PEAK+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003e∆REL:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eRecording:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes, up to 1000 points (160 hours at 10 min intervals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eBluetooth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSoftware:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes, DataView included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e4 x AA, NEDA 15A, IEC LR6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e\u0026gt;350 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e10.7 x 3.6 x 1.6\" (272 x 92 x 41mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.4 lbs (640g) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2.36\" (60mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-4° to +131°F (-20 to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-40° to +158°F (-40 to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN\/IEC 61010-1 to 1000V CAT IV\u003cimg src=\"https:\/\/www.aemc.com\/userfiles\/images\/logos\/CE_Logo.png\" alt=\"\"\u003e\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Power Clamp-on Meter with Phase Rotation\u003c\/li\u003e\n\u003cli\u003eSet of two color coded silicone insulated test leads\u003c\/li\u003e\n\u003cli\u003eTest probes and alligator clips\u003c\/li\u003e\n\u003cli\u003eHard carrying case\u003c\/li\u003e\n\u003cli\u003eFour AA Batteries\u003c\/li\u003e\n\u003cli\u003eSafety Information sheet\u003c\/li\u003e\n\u003cli\u003eDataView Software\u003c\/li\u003e\n\u003cli\u003eBluetooth adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_407-607_Clamp_Meter_-_2139-61.pdf?v=1609958892\" target=\"_blank\" title=\"AEMC 607 Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 607 Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 607 Power Clamp Meter/Data Logger, 1000 V AC/DC, 2000 A AC/3000 A DC

AEMC 607 Power Clamp Meter/Data Logger, 1000 V AC/DC, 2000 A AC/3000 A DC

$938.00 CAD

The TRMS Power Clamp-on Meter Model 607 provides a new standard for safety and measurement capability not available in any other clamp meter sold today. Safety Rated at 1000V CAT IV, it is safe to operate in most electrical environments. It is rugged enough for the most demanding work environments and will withstand both dust and water spray wit...


More Info
{"id":6155956912318,"title":"AEMC 407 Power Clamp Meter\/Data Logger, 1000 V AC\/DC, 1000 A AC\/1500 A DC","handle":"aemc-407-power-clamp-meter-data-logger-1000-v-ac-dc-1000-a-ac-1500-a-dc","description":"\u003cp\u003e\u003cspan\u003eThe TRMS Power Clamp-on Meter Model 407 provides a new standard for safety and measurement capability not available in any other clamp meter sold today. Safety Rated at 1000V CAT IV, it is safe to operate in all electrical environments. It is rugged enough for the most demanding work environments and will withstand both dust and water spray with its IP54 rating. It is ergonomically designed and easily used by one hand, including function selection and button pushing even with a glove on. In addition to the standard measurement of volts, amps, frequency, resistance, diode checking and continuity, the Model 407 offers several unequaled functions including:\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eAC, DC and AC+DC volts, amps and power,\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.aemc.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003csup\u003e®\u003c\/sup\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cspan\u003e, power measurements, harmonic analysis, data logging, and more.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1000V CAT IV Rated\u003c\/li\u003e\n\u003cli\u003eUL 94 flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003eIP54 Rated\u003c\/li\u003e\n\u003cli\u003e10,000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1000VDC and AC+DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000AAC and 2000ADC\u003c\/li\u003e\n\u003cli\u003eMeasures single- and three-phase power (real, reactive and apparent) up to 3MW with resolution to 1W\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC measurement voltage\u003c\/li\u003e\n\u003cli\u003eTrue\u003cem\u003e\u003cspan\u003e \u003c\/span\u003eInRush\u003c\/em\u003e\u003cem\u003e™\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003ecurrent measurement with 1mS capture\u003c\/li\u003e\n\u003cli\u003eRecords up to 1000 measurements\u003c\/li\u003e\n\u003cli\u003eWireless Bluetooth communications\u003c\/li\u003e\n\u003cli\u003eJaw opening up to 1.89\"\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA AC\u003c\/td\u003e\n\u003ctd\u003e0.15 to 1000A (1500A peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA DC\u003c\/td\u003e\n\u003ctd\u003e0.15 to 1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA AC+DC\u003c\/td\u003e\n\u003ctd\u003e0.15 to 1000A (1500A peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Accuracy\u003c\/td\u003e\n\u003ctd\u003e1% of Reading + 3 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV AC\u003c\/td\u003e\n\u003ctd\u003e0.15 to 1000A (1400V peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV DC\u003c\/td\u003e\n\u003ctd\u003e0.15 to 1400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV AC+DC\u003c\/td\u003e\n\u003ctd\u003e0.15 to 1000A (1400V peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Accuracy\u003c\/td\u003e\n\u003ctd\u003e1% of Reading + 3 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHz\u003c\/td\u003e\n\u003ctd\u003eCurrent: 5.0Hz to 2000Hz\u003cbr\u003eVoltage: 5.0Hz to 20.00Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOhm\u003c\/td\u003e\n\u003ctd\u003e0.1Ω to 99.99kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e≤8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Current\u003c\/td\u003e\n\u003ctd\u003e≤680μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Continuity\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Threshold\u003c\/td\u003e\n\u003ctd\u003e40Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingephase and Total Three-phase Power Values\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive Power\u003c\/td\u003e\n\u003ctd\u003e1W to 1000KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApparent Power\u003c\/td\u003e\n\u003ctd\u003e1VA to 1000kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFP \/ DPF\u003c\/td\u003e\n\u003ctd\u003eYes\/Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Analysis\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHDf\/THDr\u003c\/td\u003e\n\u003ctd\u003eYes\/Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamping Diameter\u003c\/td\u003e\n\u003ctd\u003e1.89\" (48mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eBacklit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e10,000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Values Displayed\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Power Off\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Recording\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eBluetooth communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety as per IEC 61010\u003c\/td\u003e\n\u003ctd\u003e1000V CAT IV; 1000V CAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e4 x 1.5V AA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension \u0026amp; Weight\u003c\/td\u003e\n\u003ctd\u003e3.62 x 10.70 x 1.31\" (92 x 272 x 41mm)\/ 600g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Clamp-on Meter\u003c\/li\u003e\n\u003cli\u003eSet of two color coded silicone insulated test leads\u003c\/li\u003e\n\u003cli\u003eTest probes and alligator clips\u003c\/li\u003e\n\u003cli\u003eHard carrying case\u003c\/li\u003e\n\u003cli\u003eFour AA Batteries\u003c\/li\u003e\n\u003cli\u003eSafety Information sheet\u003c\/li\u003e\n\u003cli\u003eDataView Software\u003c\/li\u003e\n\u003cli\u003eBluetooth adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_407-607_Clamp_Meter_-_2139-61.pdf?v=1609958892\" target=\"_blank\" title=\"AEMC 407 Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 407 Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-06T11:49:09-07:00","created_at":"2021-01-06T11:49:07-07:00","vendor":"AEMC Instruments","type":"Clamp Meters","tags":[],"price":77000,"price_min":77000,"price_max":77000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37839165980862,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2139.51","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 407 Power Clamp Meter\/Data Logger, 1000 V AC\/DC, 1000 A AC\/1500 A DC","public_title":null,"options":["Default Title"],"price":77000,"weight":4082,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338220421","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC407Pic1.png?v=1609958950"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC407Pic1.png?v=1609958950","options":["Title"],"media":[{"alt":null,"id":15348803141822,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC407Pic1.png?v=1609958950"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC407Pic1.png?v=1609958950","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe TRMS Power Clamp-on Meter Model 407 provides a new standard for safety and measurement capability not available in any other clamp meter sold today. Safety Rated at 1000V CAT IV, it is safe to operate in all electrical environments. It is rugged enough for the most demanding work environments and will withstand both dust and water spray with its IP54 rating. It is ergonomically designed and easily used by one hand, including function selection and button pushing even with a glove on. In addition to the standard measurement of volts, amps, frequency, resistance, diode checking and continuity, the Model 407 offers several unequaled functions including:\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003eAC, DC and AC+DC volts, amps and power,\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.aemc.com\/userfiles\/files\/resources\/applications\/clamp-on-meters\/TrueInrush.pdf\" target=\"blank\"\u003eTrue\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eInRush\u003c\/em\u003e\u003csup\u003e®\u003c\/sup\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003cspan\u003e, power measurements, harmonic analysis, data logging, and more.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1000V CAT IV Rated\u003c\/li\u003e\n\u003cli\u003eUL 94 flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003eIP54 Rated\u003c\/li\u003e\n\u003cli\u003e10,000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1000VDC and AC+DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000AAC and 2000ADC\u003c\/li\u003e\n\u003cli\u003eMeasures single- and three-phase power (real, reactive and apparent) up to 3MW with resolution to 1W\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC measurement voltage\u003c\/li\u003e\n\u003cli\u003eTrue\u003cem\u003e\u003cspan\u003e \u003c\/span\u003eInRush\u003c\/em\u003e\u003cem\u003e™\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003ecurrent measurement with 1mS capture\u003c\/li\u003e\n\u003cli\u003eRecords up to 1000 measurements\u003c\/li\u003e\n\u003cli\u003eWireless Bluetooth communications\u003c\/li\u003e\n\u003cli\u003eJaw opening up to 1.89\"\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA AC\u003c\/td\u003e\n\u003ctd\u003e0.15 to 1000A (1500A peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA DC\u003c\/td\u003e\n\u003ctd\u003e0.15 to 1000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA AC+DC\u003c\/td\u003e\n\u003ctd\u003e0.15 to 1000A (1500A peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Accuracy\u003c\/td\u003e\n\u003ctd\u003e1% of Reading + 3 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV AC\u003c\/td\u003e\n\u003ctd\u003e0.15 to 1000A (1400V peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV DC\u003c\/td\u003e\n\u003ctd\u003e0.15 to 1400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV AC+DC\u003c\/td\u003e\n\u003ctd\u003e0.15 to 1000A (1400V peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest Accuracy\u003c\/td\u003e\n\u003ctd\u003e1% of Reading + 3 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHz\u003c\/td\u003e\n\u003ctd\u003eCurrent: 5.0Hz to 2000Hz\u003cbr\u003eVoltage: 5.0Hz to 20.00Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOhm\u003c\/td\u003e\n\u003ctd\u003e0.1Ω to 99.99kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e≤8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Current\u003c\/td\u003e\n\u003ctd\u003e≤680μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Continuity\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity Threshold\u003c\/td\u003e\n\u003ctd\u003e40Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingephase and Total Three-phase Power Values\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive Power\u003c\/td\u003e\n\u003ctd\u003e1W to 1000KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApparent Power\u003c\/td\u003e\n\u003ctd\u003e1VA to 1000kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFP \/ DPF\u003c\/td\u003e\n\u003ctd\u003eYes\/Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Analysis\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTHDf\/THDr\u003c\/td\u003e\n\u003ctd\u003eYes\/Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamping Diameter\u003c\/td\u003e\n\u003ctd\u003e1.89\" (48mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eBacklit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e10,000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Values Displayed\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Power Off\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Recording\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eBluetooth communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety as per IEC 61010\u003c\/td\u003e\n\u003ctd\u003e1000V CAT IV; 1000V CAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e4 x 1.5V AA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension \u0026amp; Weight\u003c\/td\u003e\n\u003ctd\u003e3.62 x 10.70 x 1.31\" (92 x 272 x 41mm)\/ 600g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Clamp-on Meter\u003c\/li\u003e\n\u003cli\u003eSet of two color coded silicone insulated test leads\u003c\/li\u003e\n\u003cli\u003eTest probes and alligator clips\u003c\/li\u003e\n\u003cli\u003eHard carrying case\u003c\/li\u003e\n\u003cli\u003eFour AA Batteries\u003c\/li\u003e\n\u003cli\u003eSafety Information sheet\u003c\/li\u003e\n\u003cli\u003eDataView Software\u003c\/li\u003e\n\u003cli\u003eBluetooth adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_407-607_Clamp_Meter_-_2139-61.pdf?v=1609958892\" target=\"_blank\" title=\"AEMC 407 Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 407 Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 407 Power Clamp Meter/Data Logger, 1000 V AC/DC, 1000 A AC/1500 A DC

AEMC 407 Power Clamp Meter/Data Logger, 1000 V AC/DC, 1000 A AC/1500 A DC

$770.00 CAD

The TRMS Power Clamp-on Meter Model 407 provides a new standard for safety and measurement capability not available in any other clamp meter sold today. Safety Rated at 1000V CAT IV, it is safe to operate in all electrical environments. It is rugged enough for the most demanding work environments and will withstand both dust and water spray with...


More Info