Dataloggers Electrical

{"id":6192631840958,"title":"AEMC ML912 Simple Logger II AC Current Data Logger, 100\/1000 A","handle":"aemc-ml912-simple-logger-ii-ac-current-data-logger-100-1000-a","description":"\u003cp\u003e\u003cspan\u003eThe Simple Logger \u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e II Model ML912 is a two channel AC current recording device powered by two alkaline batteries. It incorporates two user selectable measurement ranges of 0 to 100 Amps and 0 to 1000 Amps. Line tracking is performed such that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency 50 or 60Hz. Harmonic measurements are calculated from these 64 samples. Harmonics are only available from the Simple Logger \u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e II Control Panel within the free DataView\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e software included with the unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTwo channel AC recording logger includes two integral MiniFlex flexible current probes that measure from 0.5A to 1000A TRMS. Stores up to 240,000 measurements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes two integral MiniFlex® flexible current probes that will measure from 0.5A to 1000A TRMS with 0.1A resolution\u003c\/li\u003e\n\u003cli\u003eDual range 100\/1000A user selectable per channel\u003c\/li\u003e\n\u003cli\u003e64 samples per cycle\u003c\/li\u003e\n\u003cli\u003eProgrammable storage rates from 8 every second to 1 every day\u003c\/li\u003e\n\u003cli\u003e4 user selectable storage modes\u003c\/li\u003e\n\u003cli\u003eStores up to 240,000 measurements in non-volatile memory\u003c\/li\u003e\n\u003cli\u003ePowered by standard Alkaline batteries\u003c\/li\u003e\n\u003cli\u003eLightweight, compact, fits anywhere\u003c\/li\u003e\n\u003cli\u003e5 LED indicators quickly and clearly display logger status\u003c\/li\u003e\n\u003cli\u003eIncludes FREE DataView® software for data storage, real-time display, analysis and report generation\u003c\/li\u003e\n\u003cli\u003eIsolated USB 2.0 communication cable included\u003c\/li\u003e\n\u003cli\u003eEN 61010-1; 600V CAT IV, 1000V CAT III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003eCaptive MiniFlex® AC Current Flexible Sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange and Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.5 to 100A AC: 0 to 1A unspecified 1 to 100A: ±(1% of Reading + 0.5A\u003cbr\u003e5 to 1000A AC: 0 to 5A unspecified 5 to 1000A: ±(1% of Reading + 1A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Rate\u003c\/td\u003e\n\u003ctd\u003e64 samples\/cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Rate\u003c\/td\u003e\n\u003ctd\u003eProgrammable from 8 every second to 1 every day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Modes\u003c\/td\u003e\n\u003ctd\u003eStart\/Stop, FIFO, Extended Recording Mode (XRM™) and Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording Length\u003c\/td\u003e\n\u003ctd\u003e15 minutes to 8 weeks, programmable using DataView®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e240,000 measurement (512KB)\u003cbr\u003eData is stored in non-volatile memory and retained if the battery is low or removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 optically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eML912 Simple Logger II\u003c\/li\u003e\n\u003cli\u003eUSB cable\u003c\/li\u003e\n\u003cli\u003eDataView® software\u003c\/li\u003e\n\u003cli\u003e2 x 1.5V AA alkaline batteries\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_ML912-14_-_2126-37.pdf?v=1611686756\" target=\"_blank\" title=\"AEMC ML912 Simple Logger II Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC ML912 Simple Logger II Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-26T11:49:20-07:00","created_at":"2021-01-26T11:49:19-07:00","vendor":"AEMC Instruments","type":"Dataloggers Electrical","tags":[],"price":98500,"price_min":98500,"price_max":98500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37963945246910,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2126.37","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC ML912 Simple Logger II AC Current Data Logger, 100\/1000 A","public_title":null,"options":["Default Title"],"price":98500,"weight":5443,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCML912Pic1.png?v=1611686961"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCML912Pic1.png?v=1611686961","options":["Title"],"media":[{"alt":null,"id":15515322810558,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCML912Pic1.png?v=1611686961"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCML912Pic1.png?v=1611686961","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Simple Logger \u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e II Model ML912 is a two channel AC current recording device powered by two alkaline batteries. It incorporates two user selectable measurement ranges of 0 to 100 Amps and 0 to 1000 Amps. Line tracking is performed such that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency 50 or 60Hz. Harmonic measurements are calculated from these 64 samples. Harmonics are only available from the Simple Logger \u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e II Control Panel within the free DataView\u003c\/span\u003e\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e software included with the unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTwo channel AC recording logger includes two integral MiniFlex flexible current probes that measure from 0.5A to 1000A TRMS. Stores up to 240,000 measurements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes two integral MiniFlex® flexible current probes that will measure from 0.5A to 1000A TRMS with 0.1A resolution\u003c\/li\u003e\n\u003cli\u003eDual range 100\/1000A user selectable per channel\u003c\/li\u003e\n\u003cli\u003e64 samples per cycle\u003c\/li\u003e\n\u003cli\u003eProgrammable storage rates from 8 every second to 1 every day\u003c\/li\u003e\n\u003cli\u003e4 user selectable storage modes\u003c\/li\u003e\n\u003cli\u003eStores up to 240,000 measurements in non-volatile memory\u003c\/li\u003e\n\u003cli\u003ePowered by standard Alkaline batteries\u003c\/li\u003e\n\u003cli\u003eLightweight, compact, fits anywhere\u003c\/li\u003e\n\u003cli\u003e5 LED indicators quickly and clearly display logger status\u003c\/li\u003e\n\u003cli\u003eIncludes FREE DataView® software for data storage, real-time display, analysis and report generation\u003c\/li\u003e\n\u003cli\u003eIsolated USB 2.0 communication cable included\u003c\/li\u003e\n\u003cli\u003eEN 61010-1; 600V CAT IV, 1000V CAT III\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003eTwo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003eCaptive MiniFlex® AC Current Flexible Sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange and Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.5 to 100A AC: 0 to 1A unspecified 1 to 100A: ±(1% of Reading + 0.5A\u003cbr\u003e5 to 1000A AC: 0 to 5A unspecified 5 to 1000A: ±(1% of Reading + 1A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Rate\u003c\/td\u003e\n\u003ctd\u003e64 samples\/cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Rate\u003c\/td\u003e\n\u003ctd\u003eProgrammable from 8 every second to 1 every day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Modes\u003c\/td\u003e\n\u003ctd\u003eStart\/Stop, FIFO, Extended Recording Mode (XRM™) and Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording Length\u003c\/td\u003e\n\u003ctd\u003e15 minutes to 8 weeks, programmable using DataView®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e240,000 measurement (512KB)\u003cbr\u003eData is stored in non-volatile memory and retained if the battery is low or removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 optically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eML912 Simple Logger II\u003c\/li\u003e\n\u003cli\u003eUSB cable\u003c\/li\u003e\n\u003cli\u003eDataView® software\u003c\/li\u003e\n\u003cli\u003e2 x 1.5V AA alkaline batteries\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_ML912-14_-_2126-37.pdf?v=1611686756\" target=\"_blank\" title=\"AEMC ML912 Simple Logger II Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC ML912 Simple Logger II Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC ML912 Simple Logger II AC Current Data Logger, 100/1000 A

AEMC ML912 Simple Logger II AC Current Data Logger, 100/1000 A

$985.00 CAD

The Simple Logger ® II Model ML912 is a two channel AC current recording device powered by two alkaline batteries. It incorporates two user selectable measurement ranges of 0 to 100 Amps and 0 to 1000 Amps. Line tracking is performed such that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around...


More Info
{"id":6192494182590,"title":"AEMC L452 DC Current\/Voltage Data Logger, 100mV\/1V\/10V DC","handle":"aemc-l452-dc-current-voltage-data-logger-100mv-1v-10v-dc","description":"\u003cp\u003e\u003cspan\u003eThe Model L452 is a low cost, simple to use, two-channel data logger. It records DC voltage, DC current, pulses and events. Its two input channels allow the user to connect to various types of sensors in order to record data such as pressure, temperature, flow, humidity and more. This logger can also be used to record events such as machine run time. Each channel's real-time measurement is displayed on the LCD screen. The L452 communicates via USB or Bluetooth for configuration and data transfer to a PC using the free DataView software included with the unit. The logger can also be configured using its front panel with a very simple user interface.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent and Voltage data logger (4-20mA, ±100mV, ±1V, ±10V) user selectable\u003c\/li\u003e\n\u003cli\u003eEvent counter, dry contact closure and logical level (pulse) detection\u003c\/li\u003e\n\u003cli\u003eReal-time display of measurements\u003c\/li\u003e\n\u003cli\u003eWireless Bluetooth communication\u003c\/li\u003e\n\u003cli\u003eCan be used to record events such as machine run time\u003c\/li\u003e\n\u003cli\u003eEach channel's real-time measurement is displayed on the LCD screen\u003c\/li\u003e\n\u003cli\u003eKeypad can be locked within the DataView software\u003c\/li\u003e\n\u003cli\u003eMagnetized rear panel\u003c\/li\u003e\n\u003cli\u003eOperates on rechargeable batteries or can be powered from the USB cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eTwo with LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e4mm safety banana jacks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eRanges (4)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e100mV\/1V\/10V, 4 to 20mA, Event \u0026amp; Pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e± 100mV, ±1V, ±10V:  ±(0.5% R +1ct)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e4 to 20mA ±(0.25% R +5ct)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003ePulse: 3.3V (with 1MΩ pull up resistor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eEvent: ± 10V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eV DC: 1MΩ, DC current: 100Ω Event: 1MΩ, Pulse N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eSample Rate Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eV \u0026amp; Current DC: 5 samples\/s, Event 16 samples\/s, Pulse 100 samples\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eStorage Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eProgrammable from 200 ms to 60 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eStorage Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eStart\/Stop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eRecording Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e15 minutes to 6 weeks, programmable using DataView\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e32MB recorded data is stored in non-volatile memory and will be retained even if battery is low or removed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eUSB 2.0, Bluetooth 2.1 Class 1 (100m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e2x1.2V 400mAh NIMH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eCharger (Supply)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eRechargeable by main 110 to 240V 50\/60Hz or via USB cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eBattery Life (Display ON)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e18 days @ 200ms sampling rate, 27 days @ 60s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eBattery Life (Display OFF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e36 days @ 200ms sampling rate, 270 days @ 60s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e4.92 x 2.60 x 1.30” (125 x 66 x 33mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eWeight (with battery)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e7.4 oz (210g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eCase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e32° to 122°F (0° to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e-4° to 140°F (-20° to 65°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eUp to 90% @ 104°F (40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eIngress Protection (IP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eEN 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eSafety Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eIEC 61010-1, EN 61010-2-30\u003cimg src=\"https:\/\/www.aemc.com\/userfiles\/images\/logos\/CE_Logo.png\" alt=\"CE symbol\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eData Logger\u003c\/li\u003e\n\u003cli\u003eUSB Stick containing DataView Software\u003c\/li\u003e\n\u003cli\u003eUSB Cable, 6ft\u003c\/li\u003e\n\u003cli\u003eWall to USB Plug, US 120V\u003c\/li\u003e\n\u003cli\u003e6-Pin Screw Terminal Block\u003c\/li\u003e\n\u003cli\u003e2 x AA Rechargeable NiHM Batteries\u003c\/li\u003e\n\u003cli\u003eQuick Start Guide\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_L452_-_2153-51.pdf?v=1611676345\" target=\"_blank\" title=\"AEMC L452 DC Current\/Voltage Data Logger\" rel=\"noopener noreferrer\"\u003eAEMC L452 DC Current\/Voltage Data Logger\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-26T09:34:07-07:00","created_at":"2021-01-26T09:32:34-07:00","vendor":"AEMC Instruments","type":"Dataloggers Electrical","tags":[],"price":78400,"price_min":78400,"price_max":78400,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37963150885054,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2153.51","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC L452 DC Current\/Voltage Data Logger, 100mV\/1V\/10V DC","public_title":null,"options":["Default Title"],"price":78400,"weight":2722,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338140521","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCL452Pic1.png?v=1611678756","\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCL452Pic2.png?v=1611678756","\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCL452Pic3.png?v=1611678757"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCL452Pic1.png?v=1611678756","options":["Title"],"media":[{"alt":null,"id":15514648281278,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCL452Pic1.png?v=1611678756"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCL452Pic1.png?v=1611678756","width":650},{"alt":null,"id":15514648314046,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1800,"width":1800,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCL452Pic2.png?v=1611678756"},"aspect_ratio":1.0,"height":1800,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCL452Pic2.png?v=1611678756","width":1800},{"alt":null,"id":15514648346814,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1800,"width":1800,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCL452Pic3.png?v=1611678757"},"aspect_ratio":1.0,"height":1800,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCL452Pic3.png?v=1611678757","width":1800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Model L452 is a low cost, simple to use, two-channel data logger. It records DC voltage, DC current, pulses and events. Its two input channels allow the user to connect to various types of sensors in order to record data such as pressure, temperature, flow, humidity and more. This logger can also be used to record events such as machine run time. Each channel's real-time measurement is displayed on the LCD screen. The L452 communicates via USB or Bluetooth for configuration and data transfer to a PC using the free DataView software included with the unit. The logger can also be configured using its front panel with a very simple user interface.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCurrent and Voltage data logger (4-20mA, ±100mV, ±1V, ±10V) user selectable\u003c\/li\u003e\n\u003cli\u003eEvent counter, dry contact closure and logical level (pulse) detection\u003c\/li\u003e\n\u003cli\u003eReal-time display of measurements\u003c\/li\u003e\n\u003cli\u003eWireless Bluetooth communication\u003c\/li\u003e\n\u003cli\u003eCan be used to record events such as machine run time\u003c\/li\u003e\n\u003cli\u003eEach channel's real-time measurement is displayed on the LCD screen\u003c\/li\u003e\n\u003cli\u003eKeypad can be locked within the DataView software\u003c\/li\u003e\n\u003cli\u003eMagnetized rear panel\u003c\/li\u003e\n\u003cli\u003eOperates on rechargeable batteries or can be powered from the USB cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eTwo with LCD display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e4mm safety banana jacks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eRanges (4)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e100mV\/1V\/10V, 4 to 20mA, Event \u0026amp; Pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e± 100mV, ±1V, ±10V:  ±(0.5% R +1ct)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e4 to 20mA ±(0.25% R +5ct)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003ePulse: 3.3V (with 1MΩ pull up resistor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eEvent: ± 10V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eV DC: 1MΩ, DC current: 100Ω Event: 1MΩ, Pulse N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eSample Rate Max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eV \u0026amp; Current DC: 5 samples\/s, Event 16 samples\/s, Pulse 100 samples\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eStorage Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eProgrammable from 200 ms to 60 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eStorage Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eStart\/Stop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eRecording Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e15 minutes to 6 weeks, programmable using DataView\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e32MB recorded data is stored in non-volatile memory and will be retained even if battery is low or removed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eUSB 2.0, Bluetooth 2.1 Class 1 (100m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e2x1.2V 400mAh NIMH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eCharger (Supply)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eRechargeable by main 110 to 240V 50\/60Hz or via USB cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eBattery Life (Display ON)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e18 days @ 200ms sampling rate, 27 days @ 60s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eBattery Life (Display OFF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e36 days @ 200ms sampling rate, 270 days @ 60s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e4.92 x 2.60 x 1.30” (125 x 66 x 33mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eWeight (with battery)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e7.4 oz (210g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eCase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e32° to 122°F (0° to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003e-4° to 140°F (-20° to 65°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eUp to 90% @ 104°F (40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eIngress Protection (IP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eEN 61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"242\" valign=\"top\"\u003e\u003cstrong\u003eSafety Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"948\" valign=\"top\"\u003eIEC 61010-1, EN 61010-2-30\u003cimg src=\"https:\/\/www.aemc.com\/userfiles\/images\/logos\/CE_Logo.png\" alt=\"CE symbol\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eData Logger\u003c\/li\u003e\n\u003cli\u003eUSB Stick containing DataView Software\u003c\/li\u003e\n\u003cli\u003eUSB Cable, 6ft\u003c\/li\u003e\n\u003cli\u003eWall to USB Plug, US 120V\u003c\/li\u003e\n\u003cli\u003e6-Pin Screw Terminal Block\u003c\/li\u003e\n\u003cli\u003e2 x AA Rechargeable NiHM Batteries\u003c\/li\u003e\n\u003cli\u003eQuick Start Guide\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_L452_-_2153-51.pdf?v=1611676345\" target=\"_blank\" title=\"AEMC L452 DC Current\/Voltage Data Logger\" rel=\"noopener noreferrer\"\u003eAEMC L452 DC Current\/Voltage Data Logger\u003c\/a\u003e\u003c\/p\u003e"}
AEMC L452 DC Current/Voltage Data Logger, 100mV/1V/10V DC

AEMC L452 DC Current/Voltage Data Logger, 100mV/1V/10V DC

$784.00 CAD

The Model L452 is a low cost, simple to use, two-channel data logger. It records DC voltage, DC current, pulses and events. Its two input channels allow the user to connect to various types of sensors in order to record data such as pressure, temperature, flow, humidity and more. This logger can also be used to record events such as machine run ...


More Info
{"id":6192471507134,"title":"AEMC SL20 Simple Logger Data Logger, 4 to 20 mADC, Current","handle":"aemc-sl20-simple-logger-data-logger-4-to-20-madc-current","description":"\u003cp\u003eThe Simple Logger\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eModel SL20 is a small one channel recording device powered by two AA alkaline batteries. It can also be powered by 5V using the USB interface cable supplied. The input is 4 - 20mADC facilitated by two screw terminals. Sample rate is 16\/sec with a storage rate of once per second of the average of all the samples. Application software is included with the unit by plugging it into your computer using the USB cable and downloading it from our web site. Scaling units of measure and recording length can be set through the software. Real-time graphs can be displayed, downloaded data can be analyzed, and reports printed.\u003c\/p\u003e\n\u003cp\u003eThe main advantage of the logger is its ability to begin recording with only the need to configure the length of time for the recording. A simple one button operation is all you need. The front panel LED alerts the operator of the logger’s status.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSimple 1 button operation\u003c\/li\u003e\n\u003cli\u003eQuick 2 wire input connection\u003c\/li\u003e\n\u003cli\u003eUser configurable scaling, units of measure and recording length\u003c\/li\u003e\n\u003cli\u003eStores up to 4 million measurements\u003c\/li\u003e\n\u003cli\u003eData analysis software included\u003c\/li\u003e\n\u003cli\u003eSoftware provides real-time trend graph display, data download, analysis and report generation\u003c\/li\u003e\n\u003cli\u003eThe input is 4 to 20 mADC facilitated by two screw terminals\u003c\/li\u003e\n\u003cli\u003eSample rate is 16\/sec with a storage rate of once per second of the average of all the samples\u003c\/li\u003e\n\u003cli\u003eScaling units of measure and recording length can be set through the software\u003c\/li\u003e\n\u003cli\u003eReal-time graphs can be displayed, downloaded data can be analyzed, and reports printed\u003c\/li\u003e\n\u003cli\u003eThe front panel LED alerts the operator of the logger's status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e±20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.02 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.5% of reading + 0.1 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Voltage\u003c\/td\u003e\n\u003ctd\u003e3 V\u003csub\u003eDC\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e49 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eInternal: 2 x 1.5 V AA non-rechargeable batteries\u003cbr\u003eExternal: USB 2.0 (computer or other power source, when powered by the USB the battery is automatically disconnected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInternal power: 1 mA (average)\u003cbr\u003eExternal power: 100 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAEMC SL20 Simple Logger Data Logger, 4 to 20 mADC, Current\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_SL20-50_-_2156-12.pdf?v=1611676132\" target=\"_blank\" title=\"AEMC SL20 Simple Logger Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC SL20 Simple Logger Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-26T08:49:23-07:00","created_at":"2021-01-26T08:49:22-07:00","vendor":"AEMC Instruments","type":"Dataloggers Electrical","tags":[],"price":20900,"price_min":20900,"price_max":20900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37962933960894,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2156.20","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC SL20 Simple Logger Data Logger, 4 to 20 mADC, Current","public_title":null,"options":["Default Title"],"price":20900,"weight":1814,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCSL20Pic1.jpg?v=1611676164"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCSL20Pic1.jpg?v=1611676164","options":["Title"],"media":[{"alt":null,"id":15514467565758,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCSL20Pic1.jpg?v=1611676164"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCSL20Pic1.jpg?v=1611676164","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe Simple Logger\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eModel SL20 is a small one channel recording device powered by two AA alkaline batteries. It can also be powered by 5V using the USB interface cable supplied. The input is 4 - 20mADC facilitated by two screw terminals. Sample rate is 16\/sec with a storage rate of once per second of the average of all the samples. Application software is included with the unit by plugging it into your computer using the USB cable and downloading it from our web site. Scaling units of measure and recording length can be set through the software. Real-time graphs can be displayed, downloaded data can be analyzed, and reports printed.\u003c\/p\u003e\n\u003cp\u003eThe main advantage of the logger is its ability to begin recording with only the need to configure the length of time for the recording. A simple one button operation is all you need. The front panel LED alerts the operator of the logger’s status.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSimple 1 button operation\u003c\/li\u003e\n\u003cli\u003eQuick 2 wire input connection\u003c\/li\u003e\n\u003cli\u003eUser configurable scaling, units of measure and recording length\u003c\/li\u003e\n\u003cli\u003eStores up to 4 million measurements\u003c\/li\u003e\n\u003cli\u003eData analysis software included\u003c\/li\u003e\n\u003cli\u003eSoftware provides real-time trend graph display, data download, analysis and report generation\u003c\/li\u003e\n\u003cli\u003eThe input is 4 to 20 mADC facilitated by two screw terminals\u003c\/li\u003e\n\u003cli\u003eSample rate is 16\/sec with a storage rate of once per second of the average of all the samples\u003c\/li\u003e\n\u003cli\u003eScaling units of measure and recording length can be set through the software\u003c\/li\u003e\n\u003cli\u003eReal-time graphs can be displayed, downloaded data can be analyzed, and reports printed\u003c\/li\u003e\n\u003cli\u003eThe front panel LED alerts the operator of the logger's status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e±20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.02 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.5% of reading + 0.1 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Voltage\u003c\/td\u003e\n\u003ctd\u003e3 V\u003csub\u003eDC\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e49 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eInternal: 2 x 1.5 V AA non-rechargeable batteries\u003cbr\u003eExternal: USB 2.0 (computer or other power source, when powered by the USB the battery is automatically disconnected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInternal power: 1 mA (average)\u003cbr\u003eExternal power: 100 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAEMC SL20 Simple Logger Data Logger, 4 to 20 mADC, Current\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_SL20-50_-_2156-12.pdf?v=1611676132\" target=\"_blank\" title=\"AEMC SL20 Simple Logger Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC SL20 Simple Logger Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC SL20 Simple Logger Data Logger, 4 to 20 mADC, Current

AEMC SL20 Simple Logger Data Logger, 4 to 20 mADC, Current

$209.00 CAD

The Simple Logger® Model SL20 is a small one channel recording device powered by two AA alkaline batteries. It can also be powered by 5V using the USB interface cable supplied. The input is 4 - 20mADC facilitated by two screw terminals. Sample rate is 16/sec with a storage rate of once per second of the average of all the samples. Application so...


More Info
AEMC SL12 Simple Logger Data Logger, 10 VDC, Voltage

Dataloggers Electrical

$209.00 CAD
{"id":6192465772734,"title":"AEMC SL12 Simple Logger Data Logger, 10 VDC, Voltage","handle":"aemc-sl12-simple-logger-data-logger-10-vdc-voltage","description":"\u003cp\u003eThe Simple Logger\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eModel SL12 is a small one channel recording device powered by two AA alkaline batteries. It can also be powered by 5V using the USB interface cable supplied. The input is 0 - 10VDC facilitated by two screw terminals. Sample rate is 16\/sec with a storage rate of once per second of the average of all the samples. Application software is included with the unit by plugging it into your computer using the USB cable and downloading it from our web site. Scaling units of measure and recording length can be set through the software. Real-time graphs can be displayed, downloaded data can be analyzed, and reports printed.\u003c\/p\u003e\n\u003cp\u003eThe main advantage of the logger is its ability to begin recording with only the need to configure the length of time for the recording. A simple one button operation is all you need. The front panel LED alerts the operator of the logger’s status.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSimple 1 button operation\u003c\/li\u003e\n\u003cli\u003eQuick 2 wire input connection\u003c\/li\u003e\n\u003cli\u003eUser configurable scaling, units of measure and recording length\u003c\/li\u003e\n\u003cli\u003eStores up to 4 million measurements\u003c\/li\u003e\n\u003cli\u003eData analysis software included\u003c\/li\u003e\n\u003cli\u003eSoftware provides real-time trend graph display, data download, analysis and report generation\u003c\/li\u003e\n\u003cli\u003eThe input is 0 to 10 VDC facilitated by two screw terminals\u003c\/li\u003e\n\u003cli\u003eSample rate is 16\/sec with a storage rate of once per second of the average of all the samples\u003c\/li\u003e\n\u003cli\u003eScaling units of measure and recording length can be set through the software\u003c\/li\u003e\n\u003cli\u003eReal-time graphs can be displayed, downloaded data can be analyzed, and reports printed\u003c\/li\u003e\n\u003cli\u003eThe front panel LED alerts the operator of the logger's status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e±10 V\u003csub\u003eDC\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e10 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.5% of reading + 50 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Voltage\u003c\/td\u003e\n\u003ctd\u003e60 V\u003csub\u003eDC\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e800 KΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eInternal: 2 x 1.5 V AA non-rechargeable batteries\u003cbr\u003eExternal: USB 2.0 (computer or other USB power source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInternal power: 1 mA (average)\u003cbr\u003eExternal power: 100 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eData Logger\u003c\/li\u003e\n\u003cli\u003eMicro-B USB Cable\u003c\/li\u003e\n\u003cli\u003eData Analysis Software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_SL01-13_-_2156-12.pdf?v=1611675345\" target=\"_blank\" title=\"AEMC SL12 Simple Logger Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC SL12 Simple Logger Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-26T08:39:24-07:00","created_at":"2021-01-26T08:39:23-07:00","vendor":"AEMC Instruments","type":"Dataloggers Electrical","tags":[],"price":20900,"price_min":20900,"price_max":20900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37962899128510,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2156.12","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC SL12 Simple Logger Data Logger, 10 VDC, Voltage","public_title":null,"options":["Default Title"],"price":20900,"weight":1814,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCSL12Pic1.jpg?v=1611675567"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCSL12Pic1.jpg?v=1611675567","options":["Title"],"media":[{"alt":null,"id":15514418970814,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCSL12Pic1.jpg?v=1611675567"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCSL12Pic1.jpg?v=1611675567","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe Simple Logger\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eModel SL12 is a small one channel recording device powered by two AA alkaline batteries. It can also be powered by 5V using the USB interface cable supplied. The input is 0 - 10VDC facilitated by two screw terminals. Sample rate is 16\/sec with a storage rate of once per second of the average of all the samples. Application software is included with the unit by plugging it into your computer using the USB cable and downloading it from our web site. Scaling units of measure and recording length can be set through the software. Real-time graphs can be displayed, downloaded data can be analyzed, and reports printed.\u003c\/p\u003e\n\u003cp\u003eThe main advantage of the logger is its ability to begin recording with only the need to configure the length of time for the recording. A simple one button operation is all you need. The front panel LED alerts the operator of the logger’s status.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSimple 1 button operation\u003c\/li\u003e\n\u003cli\u003eQuick 2 wire input connection\u003c\/li\u003e\n\u003cli\u003eUser configurable scaling, units of measure and recording length\u003c\/li\u003e\n\u003cli\u003eStores up to 4 million measurements\u003c\/li\u003e\n\u003cli\u003eData analysis software included\u003c\/li\u003e\n\u003cli\u003eSoftware provides real-time trend graph display, data download, analysis and report generation\u003c\/li\u003e\n\u003cli\u003eThe input is 0 to 10 VDC facilitated by two screw terminals\u003c\/li\u003e\n\u003cli\u003eSample rate is 16\/sec with a storage rate of once per second of the average of all the samples\u003c\/li\u003e\n\u003cli\u003eScaling units of measure and recording length can be set through the software\u003c\/li\u003e\n\u003cli\u003eReal-time graphs can be displayed, downloaded data can be analyzed, and reports printed\u003c\/li\u003e\n\u003cli\u003eThe front panel LED alerts the operator of the logger's status\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e±10 V\u003csub\u003eDC\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e10 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.5% of reading + 50 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Voltage\u003c\/td\u003e\n\u003ctd\u003e60 V\u003csub\u003eDC\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e800 KΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eInternal: 2 x 1.5 V AA non-rechargeable batteries\u003cbr\u003eExternal: USB 2.0 (computer or other USB power source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInternal power: 1 mA (average)\u003cbr\u003eExternal power: 100 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eData Logger\u003c\/li\u003e\n\u003cli\u003eMicro-B USB Cable\u003c\/li\u003e\n\u003cli\u003eData Analysis Software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_SL01-13_-_2156-12.pdf?v=1611675345\" target=\"_blank\" title=\"AEMC SL12 Simple Logger Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC SL12 Simple Logger Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC SL12 Simple Logger Data Logger, 10 VDC, Voltage

AEMC SL12 Simple Logger Data Logger, 10 VDC, Voltage

$209.00 CAD

The Simple Logger® Model SL12 is a small one channel recording device powered by two AA alkaline batteries. It can also be powered by 5V using the USB interface cable supplied. The input is 0 - 10VDC facilitated by two screw terminals. Sample rate is 16/sec with a storage rate of once per second of the average of all the samples. Application sof...


More Info
{"id":1314802827307,"title":"Monarch Instruments Analog 500mV Track-It LB Data Logger","handle":"monarch-instruments-analog-500mv-track-it-lb-data-logger","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Track-It\u003c\/span\u003e\u003cspan\u003e™\u003c\/span\u003e\u003cspan\u003e DC Voltage and Current Data Loggers are two channel battery powered stand alone compact data loggers that record up to 32,000 samples each of DC Voltage or Current data. Units are available in 4 DC voltage ranges or for DC current. The unit is easily configured using the included Track-It\u003c\/span\u003e\u003cspan\u003e™\u003c\/span\u003e\u003cspan\u003e Software. Simply plug the logger into an open USB port on your PC and the software automatically identifies the logger. Configure the unit to start and stop recording at a predetermined time and date or only when an alarm condition is sensed. The sample storage rate can be set from 1 sample every 2 seconds to 1 sample every 24 hours.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe on board data storage is non-volatile so data will not be lost in the event of a depleted battery. The Track-It\u003c\/span\u003e\u003cspan\u003e™\u003c\/span\u003e\u003cspan\u003e DC Voltage and Current Loggers can also be used to record ambient temperature if one or neither input is being used. Information displayed on the LCD is also user programmable and can be sequenced by pressing the logger button. A multicolored LED indicator notifies the user of alarms, or general activity.\u003c\/span\u003e\u003c\/p\u003e","published_at":"2018-06-08T16:42:32-06:00","created_at":"2018-06-08T16:47:54-06:00","vendor":"Monarch Instruments","type":"Dataloggers Electrical","tags":[],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12498992234539,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Monarch Instruments Analog 500mV Track-It LB Data Logger","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/81sZ46-nndL._SL1500_b2e33007-311a-4bc6-bf93-b66c27e0cfb3.jpg?v=1528498076"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/81sZ46-nndL._SL1500_b2e33007-311a-4bc6-bf93-b66c27e0cfb3.jpg?v=1528498076","options":["Title"],"media":[{"alt":null,"id":1747096633387,"position":1,"preview_image":{"aspect_ratio":1.901,"height":789,"width":1500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/81sZ46-nndL._SL1500_b2e33007-311a-4bc6-bf93-b66c27e0cfb3.jpg?v=1528498076"},"aspect_ratio":1.901,"height":789,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/81sZ46-nndL._SL1500_b2e33007-311a-4bc6-bf93-b66c27e0cfb3.jpg?v=1528498076","width":1500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Track-It\u003c\/span\u003e\u003cspan\u003e™\u003c\/span\u003e\u003cspan\u003e DC Voltage and Current Data Loggers are two channel battery powered stand alone compact data loggers that record up to 32,000 samples each of DC Voltage or Current data. Units are available in 4 DC voltage ranges or for DC current. The unit is easily configured using the included Track-It\u003c\/span\u003e\u003cspan\u003e™\u003c\/span\u003e\u003cspan\u003e Software. Simply plug the logger into an open USB port on your PC and the software automatically identifies the logger. Configure the unit to start and stop recording at a predetermined time and date or only when an alarm condition is sensed. The sample storage rate can be set from 1 sample every 2 seconds to 1 sample every 24 hours.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe on board data storage is non-volatile so data will not be lost in the event of a depleted battery. The Track-It\u003c\/span\u003e\u003cspan\u003e™\u003c\/span\u003e\u003cspan\u003e DC Voltage and Current Loggers can also be used to record ambient temperature if one or neither input is being used. Information displayed on the LCD is also user programmable and can be sequenced by pressing the logger button. A multicolored LED indicator notifies the user of alarms, or general activity.\u003c\/span\u003e\u003c\/p\u003e"}
Monarch Instruments Analog 500mV Track-It LB Data Logger

Monarch Instruments Analog 500mV Track-It LB Data Logger

Call for pricing

The Track-It™ DC Voltage and Current Data Loggers are two channel battery powered stand alone compact data loggers that record up to 32,000 samples each of DC Voltage or Current data. Units are available in 4 DC voltage ranges or for DC current. The unit is easily configured using the included Track-It™ Software. Simply plug the logger into an ...


More Info
{"id":1324909002795,"title":"Monarch Instruments Analog 500mV Track-It Data Logger","handle":"monarch-instruments-analog-500mv-track-it-data-logger","description":"The Track-It™ DC Voltage and Current Data Loggers are two channel battery powered stand alone compact data loggers that record up to 32,000 samples each of DC Voltage or Current data. Units are available in 4 DC voltage ranges or for DC current. The unit is easily configured using the included Track-It™ Software. Simply plug the logger into an open USB port on your PC and the software automatically identifies the logger. Configure the unit to start and stop recording at a predetermined time and date or only when an alarm condition is sensed. The sample storage rate can be set from 1 sample every 2 seconds to 1 sample every 24 hours.\u003cbr\u003e\u003cbr\u003eThe on board data storage is non-volatile so data will not be lost in the event of a depleted battery. The Track-It™ DC Voltage and Current Loggers can also be used to record ambient temperature if one or neither input is being used. Information displayed on the LCD is also user programmable and can be sequenced by pressing the logger button. A multicolored LED indicator notifies the user of alarms, or general activity.","published_at":"2018-06-11T11:45:40-06:00","created_at":"2018-06-11T11:47:08-06:00","vendor":"Monarch Instruments","type":"Dataloggers Electrical","tags":[],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12592141172779,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Monarch Instruments Analog 500mV Track-It Data Logger","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Track-It_Logger_20mA_2_1024x1024_84b339cf-6377-4b38-ac15-169f0f9ba30c.jpg?v=1528739230"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Track-It_Logger_20mA_2_1024x1024_84b339cf-6377-4b38-ac15-169f0f9ba30c.jpg?v=1528739230","options":["Title"],"media":[{"alt":null,"id":1801264398379,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Track-It_Logger_20mA_2_1024x1024_84b339cf-6377-4b38-ac15-169f0f9ba30c.jpg?v=1528739230"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Track-It_Logger_20mA_2_1024x1024_84b339cf-6377-4b38-ac15-169f0f9ba30c.jpg?v=1528739230","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"The Track-It™ DC Voltage and Current Data Loggers are two channel battery powered stand alone compact data loggers that record up to 32,000 samples each of DC Voltage or Current data. Units are available in 4 DC voltage ranges or for DC current. The unit is easily configured using the included Track-It™ Software. Simply plug the logger into an open USB port on your PC and the software automatically identifies the logger. Configure the unit to start and stop recording at a predetermined time and date or only when an alarm condition is sensed. The sample storage rate can be set from 1 sample every 2 seconds to 1 sample every 24 hours.\u003cbr\u003e\u003cbr\u003eThe on board data storage is non-volatile so data will not be lost in the event of a depleted battery. The Track-It™ DC Voltage and Current Loggers can also be used to record ambient temperature if one or neither input is being used. Information displayed on the LCD is also user programmable and can be sequenced by pressing the logger button. A multicolored LED indicator notifies the user of alarms, or general activity."}
Monarch Instruments Analog 500mV Track-It Data Logger

Monarch Instruments Analog 500mV Track-It Data Logger

Call for pricing

The Track-It™ DC Voltage and Current Data Loggers are two channel battery powered stand alone compact data loggers that record up to 32,000 samples each of DC Voltage or Current data. Units are available in 4 DC voltage ranges or for DC current. The unit is easily configured using the included Track-It™ Software. Simply plug the logger into an o...


More Info
{"id":1314786476075,"title":"Monarch Instruments Analog 20mA Track-It LB Data Logger","handle":"monarch-instruments-analog-20ma-track-it-lb-data-logger","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Track-It\u003c\/span\u003e\u003cspan\u003e™\u003c\/span\u003e\u003cspan\u003e DC Voltage and Current Data Loggers are two channel battery powered stand alone compact data loggers that record up to 32,000 samples each of DC Voltage or Current data. Units are available in 4 DC voltage ranges or for DC current. The unit is easily configured using the included Track-It\u003c\/span\u003e\u003cspan\u003e™\u003c\/span\u003e\u003cspan\u003e Software. Simply plug the logger into an open USB port on your PC and the software automatically identifies the logger. Configure the unit to start and stop recording at a predetermined time and date or only when an alarm condition is sensed. The sample storage rate can be set from 1 sample every 2 seconds to 1 sample every 24 hours.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe on board data storage is non-volatile so data will not be lost in the event of a depleted battery. The Track-It\u003c\/span\u003e\u003cspan\u003e™\u003c\/span\u003e\u003cspan\u003e DC Voltage and Current Loggers can also be used to record ambient temperature if one or neither input is being used. Information displayed on the LCD is also user programmable and can be sequenced by pressing the logger button. A multicolored LED indicator notifies the user of alarms, or general activity.\u003c\/span\u003e\u003c\/p\u003e","published_at":"2018-06-08T16:37:39-06:00","created_at":"2018-06-08T16:40:31-06:00","vendor":"Monarch Instruments","type":"Dataloggers Electrical","tags":[],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12498792644651,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Monarch Instruments Analog 20mA Track-It LB Data Logger","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/81sZ46-nndL._SL1500.jpg?v=1528497632"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/81sZ46-nndL._SL1500.jpg?v=1528497632","options":["Title"],"media":[{"alt":null,"id":1746980798507,"position":1,"preview_image":{"aspect_ratio":1.901,"height":789,"width":1500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/81sZ46-nndL._SL1500.jpg?v=1528497632"},"aspect_ratio":1.901,"height":789,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/81sZ46-nndL._SL1500.jpg?v=1528497632","width":1500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Track-It\u003c\/span\u003e\u003cspan\u003e™\u003c\/span\u003e\u003cspan\u003e DC Voltage and Current Data Loggers are two channel battery powered stand alone compact data loggers that record up to 32,000 samples each of DC Voltage or Current data. Units are available in 4 DC voltage ranges or for DC current. The unit is easily configured using the included Track-It\u003c\/span\u003e\u003cspan\u003e™\u003c\/span\u003e\u003cspan\u003e Software. Simply plug the logger into an open USB port on your PC and the software automatically identifies the logger. Configure the unit to start and stop recording at a predetermined time and date or only when an alarm condition is sensed. The sample storage rate can be set from 1 sample every 2 seconds to 1 sample every 24 hours.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe on board data storage is non-volatile so data will not be lost in the event of a depleted battery. The Track-It\u003c\/span\u003e\u003cspan\u003e™\u003c\/span\u003e\u003cspan\u003e DC Voltage and Current Loggers can also be used to record ambient temperature if one or neither input is being used. Information displayed on the LCD is also user programmable and can be sequenced by pressing the logger button. A multicolored LED indicator notifies the user of alarms, or general activity.\u003c\/span\u003e\u003c\/p\u003e"}
Monarch Instruments Analog 20mA Track-It LB Data Logger

Monarch Instruments Analog 20mA Track-It LB Data Logger

Call for pricing

The Track-It™ DC Voltage and Current Data Loggers are two channel battery powered stand alone compact data loggers that record up to 32,000 samples each of DC Voltage or Current data. Units are available in 4 DC voltage ranges or for DC current. The unit is easily configured using the included Track-It™ Software. Simply plug the logger into an ...


More Info
Monarch Instruments Analog 20mA Track-It Data Logger

Dataloggers Electrical

$235.00 CAD
{"id":1324906577963,"title":"Monarch Instruments Analog 20mA Track-It Data Logger","handle":"monarch-instruments-analog-20ma-track-it-data-logger","description":"The Track-It™ DC Voltage and Current Data Loggers are two channel battery powered stand alone compact data loggers that record up to 32,000 samples each of DC Voltage or Current data. Units are available in 4 DC voltage ranges or for DC current. The unit is easily configured using the included Track-It™ Software. Simply plug the logger into an open USB port on your PC and the software automatically identifies the logger. Configure the unit to start and stop recording at a predetermined time and date or only when an alarm condition is sensed. The sample storage rate can be set from 1 sample every 2 seconds to 1 sample every 24 hours.\u003cbr\u003e\u003cbr\u003eThe on board data storage is non-volatile so data will not be lost in the event of a depleted battery. The Track-It™ DC Voltage and Current Loggers can also be used to record ambient temperature if one or neither input is being used. Information displayed on the LCD is also user programmable and can be sequenced by pressing the logger button. A multicolored LED indicator notifies the user of alarms, or general activity.","published_at":"2018-06-11T11:44:14-06:00","created_at":"2018-06-11T11:45:36-06:00","vendor":"Monarch Instruments","type":"Dataloggers Electrical","tags":[],"price":23500,"price_min":23500,"price_max":23500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12592097329195,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MON-5396-0525","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Monarch Instruments Analog 20mA Track-It Data Logger","public_title":null,"options":["Default Title"],"price":23500,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Track-It_Logger_20mA_2_1024x1024_e0e93aa8-ffe5-4ad8-8943-246628c0bbff.jpg?v=1528739138"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Track-It_Logger_20mA_2_1024x1024_e0e93aa8-ffe5-4ad8-8943-246628c0bbff.jpg?v=1528739138","options":["Title"],"media":[{"alt":null,"id":1801244835883,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Track-It_Logger_20mA_2_1024x1024_e0e93aa8-ffe5-4ad8-8943-246628c0bbff.jpg?v=1528739138"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Track-It_Logger_20mA_2_1024x1024_e0e93aa8-ffe5-4ad8-8943-246628c0bbff.jpg?v=1528739138","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"The Track-It™ DC Voltage and Current Data Loggers are two channel battery powered stand alone compact data loggers that record up to 32,000 samples each of DC Voltage or Current data. Units are available in 4 DC voltage ranges or for DC current. The unit is easily configured using the included Track-It™ Software. Simply plug the logger into an open USB port on your PC and the software automatically identifies the logger. Configure the unit to start and stop recording at a predetermined time and date or only when an alarm condition is sensed. The sample storage rate can be set from 1 sample every 2 seconds to 1 sample every 24 hours.\u003cbr\u003e\u003cbr\u003eThe on board data storage is non-volatile so data will not be lost in the event of a depleted battery. The Track-It™ DC Voltage and Current Loggers can also be used to record ambient temperature if one or neither input is being used. Information displayed on the LCD is also user programmable and can be sequenced by pressing the logger button. A multicolored LED indicator notifies the user of alarms, or general activity."}
Monarch Instruments Analog 20mA Track-It Data Logger

Monarch Instruments Analog 20mA Track-It Data Logger

$235.00 CAD

The Track-It™ DC Voltage and Current Data Loggers are two channel battery powered stand alone compact data loggers that record up to 32,000 samples each of DC Voltage or Current data. Units are available in 4 DC voltage ranges or for DC current. The unit is easily configured using the included Track-It™ Software. Simply plug the logger into an o...


More Info
Monarch Instruments Analog 10V Track-It LB Data Logger

Dataloggers Electrical

$195.00 CAD
{"id":1324588269611,"title":"Monarch Instruments Analog 10V Track-It LB Data Logger","handle":"monarch-instruments-analog-1v-track-it-lb-data-logger","description":"\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eThe Track-It™ DC Voltage and Current Data Loggers are two channel battery powered stand alone compact data loggers that record up to 32,000 samples each of DC Voltage or Current data. Units are available in 4 DC voltage ranges or for DC current. The unit is easily configured using the included Track-It™ Software. Simply plug the logger into an open USB port on your PC and the software automatically identifies the logger. Configure the unit to start and stop recording at a predetermined time and date or only when an alarm condition is sensed. The sample storage rate can be set from 1 sample every 2 seconds to 1 sample every 24 hours.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eThe on board data storage is non-volatile so data will not be lost in the event of a depleted battery. The Track-It™ DC Voltage and Current Loggers can also be used to record ambient temperature if one or neither input is being used. Information displayed on the LCD is also user programmable and can be sequenced by pressing the logger button. A multicolored LED indicator notifies the user of alarms, or general activity.\u003c\/span\u003e\u003c\/p\u003e","published_at":"2018-06-11T09:44:57-06:00","created_at":"2018-06-11T09:48:21-06:00","vendor":"Monarch Instruments","type":"Dataloggers Electrical","tags":[],"price":19500,"price_min":19500,"price_max":19500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12589675937835,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MON-5396-0514","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Monarch Instruments Analog 10V Track-It LB Data Logger","public_title":null,"options":["Default Title"],"price":19500,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/81sZ46-nndL._SL1500_-1.jpg?v=1528732104"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/81sZ46-nndL._SL1500_-1.jpg?v=1528732104","options":["Title"],"media":[{"alt":null,"id":1799797178411,"position":1,"preview_image":{"aspect_ratio":1.901,"height":789,"width":1500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/81sZ46-nndL._SL1500_-1.jpg?v=1528732104"},"aspect_ratio":1.901,"height":789,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/81sZ46-nndL._SL1500_-1.jpg?v=1528732104","width":1500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eThe Track-It™ DC Voltage and Current Data Loggers are two channel battery powered stand alone compact data loggers that record up to 32,000 samples each of DC Voltage or Current data. Units are available in 4 DC voltage ranges or for DC current. The unit is easily configured using the included Track-It™ Software. Simply plug the logger into an open USB port on your PC and the software automatically identifies the logger. Configure the unit to start and stop recording at a predetermined time and date or only when an alarm condition is sensed. The sample storage rate can be set from 1 sample every 2 seconds to 1 sample every 24 hours.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"s1\"\u003eThe on board data storage is non-volatile so data will not be lost in the event of a depleted battery. The Track-It™ DC Voltage and Current Loggers can also be used to record ambient temperature if one or neither input is being used. Information displayed on the LCD is also user programmable and can be sequenced by pressing the logger button. A multicolored LED indicator notifies the user of alarms, or general activity.\u003c\/span\u003e\u003c\/p\u003e"}
Monarch Instruments Analog 10V Track-It LB Data Logger

Monarch Instruments Analog 10V Track-It LB Data Logger

$195.00 CAD

The Track-It™ DC Voltage and Current Data Loggers are two channel battery powered stand alone compact data loggers that record up to 32,000 samples each of DC Voltage or Current data. Units are available in 4 DC voltage ranges or for DC current. The unit is easily configured using the included Track-It™ Software. Simply plug the logger into an o...


More Info