{ "id":6196047544510, "title":"AEMC 5233 True RMS Multimeter with Non-Contact Voltage Detection and Temperature","handle":"aemc-5233-true-rms-multimeter-with-non-contact-voltage-detection-and-temperature", "description":"\u003cp\u003eThe Model 5233 is a rugged, economical TRMS digital multimeter with a function for non-electrical contact testing (NCV) function for detecting live electrical circuits. This multimeter is designed for safety: IEC61010, 600V CAT IV. The Multimeter Model 5233 provides a Volt, Ohm, Continuity, Diode, Capacitance, Frequency, Duty Cycle and Ammeter function, as well as an AC voltmeter with low input impedance that is capable of finding ghost voltages by adding a burden to the circuit. It can measure up to 10 Amps directly and can measure temperature in both °C or °F using K-type thermocouples.\u003c\/p\u003e\n\u003cp\u003eThe rotary function switch provides two OFF positions (OFF and OFF NCV). While in the OFF NCV position, the display will turn red if placed close to a live cable, providing a safe and easy way to detect hot wires. This meter has a high sensitivity with a resolution of 0.01mV and can withstand overloads up to 8000V.\u003c\/p\u003e\n\u003cp\u003eThe Model 5233 is ideal for electrical installers, electricians and heating or air-conditioning specialists.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNon-electrical contact detection of network voltage (NCV Function)\u003c\/li\u003e\n\u003cli\u003eHigh sensitivity with a resolution of 0.01mV\u003c\/li\u003e\n\u003cli\u003eAC voltmeter with low input impedance (voltage measurements for electricity and electrical engineering)\u003c\/li\u003e\n\u003cli\u003eAC\/DC voltmeter with high input impedance (voltage measurements for electronics)\u003c\/li\u003e\n\u003cli\u003eOhmmeter, Continuity test with buzzer, Diode test and Capacitance functions\u003c\/li\u003e\n\u003cli\u003eFrequency and Duty Cycle measurements\u003c\/li\u003e\n\u003cli\u003eWithstands overloads up to 8000V\u003c\/li\u003e\n\u003cli\u003eVLowZ function detects the presence of ghost voltage by placing a burden on the circuit\u003c\/li\u003e\n\u003cli\u003eMulti-position mounting for a hands-free work environment\u003c\/li\u003e\n\u003cli\u003eIEC\/EN 61010-1, 1000V CAT III, 600V CAT IV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eCounts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eVoltage AC\/DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e1000VAC\/600VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eCurrent AC\/DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e10AAC\/DC (15A for 60s max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eBandwidth AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e1kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e60MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e3kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eCapacitance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e1mF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eContinuity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e\u0026lt;20Ω+3Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eNon-Contact Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e\u0026gt;90V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eTemperature (K-type TC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e-4° to 1400°F (20° to 760°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eDiode Test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\n\u003cstrong\u003eV\u003c\/strong\u003e\u003cstrong\u003eLow\u003c\/strong\u003e\u003cstrong\u003eZ\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eDuty Cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003e∆REL\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eMIN\/MAX\/AVG\/PEAK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003eMIN\/MAX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003eDigital with 61-segment analog bargraph and backlighting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eDimensions  (HxWxD)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e6.1 x 2.95 x 2.17\" (155 x 75 x 55mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e11oz (320g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003ePower Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e9V alkaline battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eBattery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e\u0026gt;100 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e-4° to 158°F (-20° to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e-32° to 122°F (-35° to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eIngress Protection (IP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eEMC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003eEN 61326\/A2:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"205\" valign=\"top\"\u003e\u003cstrong\u003eSafety Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\" colspan=\"2\"\u003eIEC\/EN 61010-1, 1000V CAT III, 600V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrue RMS Multimeter\u003c\/li\u003e\n\u003cli\u003e2 x 5ft red and black leads with needle tips, 1000V CAT IV 15A\u003c\/li\u003e\n\u003cli\u003eType-K Thermocouple with adapter\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_5000_Series_-_2154-09.pdf?v=1611873358\" target=\"_blank\" title=\"AEMC 5233 True RMS DMM Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 5233 True RMS DMM Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2021-01-28T15:45:29", "created_at":"2021-01-28T15:45:28", "vendor":"AEMC Instruments", "type":"Multimeters", "tags":[], "price":14700, "price_min":14700, "price_max":14700, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[37978394001598], "variants":[{ "id":37978394001598, "product_id":6196047544510, "product_handle":"aemc-5233-true-rms-multimeter-with-non-contact-voltage-detection-and-temperature", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"AEMC-2125.65", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"AEMC 5233 True RMS Multimeter with Non-Contact Voltage Detection and Temperature - Default Title", "options":["Default Title"], "price":14700, "weight":2722, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"685338170191"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC5233Pic1.png?v=1611873930"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC5233Pic1.png?v=1611873930", "options":["Title"], "url":"\/products\/aemc-5233-true-rms-multimeter-with-non-contact-voltage-detection-and-temperature"}

AEMC 5233 True RMS Multimeter with Non-Contact Voltage Detection and Temperature

Product Description

The Model 5233 is a rugged, economical TRMS digital multimeter with a function for non-electrical contact testing (NCV) function for detecting live electrical circuits. This multimeter is designed for safety: IEC61010, 600V CAT IV. The Multimeter Model 5233 provides a Volt, Ohm, Continuity, Diode, Capacitance, Frequency, Duty Cycle and Ammeter function, as well as an AC voltmeter with low input impedance that is capable of finding ghost voltages by adding a burden to the circuit. It can measure up to 10 Amps directly and can measure temperature in both °C or °F using K-type thermocouples.

The rotary function switch provides two OFF positions (OFF and OFF NCV). While in the OFF NCV position, the display will turn red if placed close to a live cable, providing a safe and easy way to detect hot wires. This meter has a high sensitivity with a resolution of 0.01mV and can withstand overloads up to 8000V.

The Model 5233 is ideal for electrical installers, electricians and heating or air-conditioning specialists.

Sku: AEMC-2125.65
On Back-Order
$147.00 CAD

  • Non-electrical contact detection of network voltage (NCV Function)
  • High sensitivity with a resolution of 0.01mV
  • AC voltmeter with low input impedance (voltage measurements for electricity and electrical engineering)
  • AC/DC voltmeter with high input impedance (voltage measurements for electronics)
  • Ohmmeter, Continuity test with buzzer, Diode test and Capacitance functions
  • Frequency and Duty Cycle measurements
  • Withstands overloads up to 8000V
  • VLowZ function detects the presence of ghost voltage by placing a burden on the circuit
  • Multi-position mounting for a hands-free work environment
  • IEC/EN 61010-1, 1000V CAT III, 600V CAT IV
Counts 6000
Voltage AC/DC 1000VAC/600VDC
Current AC/DC 10AAC/DC (15A for 60s max)
Bandwidth AC 1kHz
Resistance 60MΩ
Frequency 3kHz
Capacitance 1mF
Continuity <20Ω+3Ω
Non-Contact Voltage >90V
Temperature (K-type TC) -4° to 1400°F (20° to 760°C)
Diode Test Yes
VLowZ Yes
Duty Cycle Yes
∆REL Yes
MIN/MAX/AVG/PEAK MIN/MAX
Display Digital with 61-segment analog bargraph and backlighting
Dimensions  (HxWxD) 6.1 x 2.95 x 2.17" (155 x 75 x 55mm)
Weight 11oz (320g)
Power Source 9V alkaline battery
Battery Life >100 hours
Operating Temperature -4° to 158°F (-20° to 70°C)
Storage Temperature -32° to 122°F (-35° to 50°C)
Pollution Degree 2
Ingress Protection (IP) IP54
EMC EN 61326/A2:2001
Safety Compliance IEC/EN 61010-1, 1000V CAT III, 600V CAT IV


  • True RMS Multimeter
  • 2 x 5ft red and black leads with needle tips, 1000V CAT IV 15A
  • Type-K Thermocouple with adapter
  • Soft carrying case
  • Manual

Related Products