Fluke T6-600 Electrical Tester
Product Description
Measure voltage … without test leads
We know working in electrical boxes jammed with wires can be challenging when you’re trying to find a safe metallic contact point. Now, with Fluke’s T6-600 or T6-1000 with integrated FieldSense technology, you can quickly and easily take measurements by sliding the open fork over a conductor to see the voltage level without the need for test leads.*
Overview
5 reasons the T6 belongs in your toolbelt
- Be safer: Measure voltage to 600 V ac through the open fork, without test leads.
- Be faster: No need to open covers or remove wire nuts.
- Be more efficient: Simultaneously measure voltage and current.
- Be everywhere: 17.8 mm open fork is widest in the industry; measure up to 200 A on 4/0 wires (120 mm2).
- Go beyond simple detection. Actually measure ac voltage and current values without test leads.
Product Highlights
- FieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage*
- See voltage or current display – shows all power supply measurements at a glance for efficient trouble shooting
- 1 to 600 V ac or dc (T6-600)
- 0 to 200 A ac
- True-rms voltage and current
- Resistance 1 Ω to 2000 Ω
- Works with wires up to AWG 4/0 (120 mm2) with a 17.8 mm jaw opening
- HOLD button temporarily freezes the reading for easy viewing
- Easy to read display with backlight
- Accepts optional Fluke TPAK Magnetic Meter Hanger for convenient operation
- Standard two-year warranty; extendable to 4 years through product registration within 45 days of purchase+
Specifications
Function | Requires test leads | Range | Resolution | Accuracy[1] |
---|---|---|---|---|
FieldSense ac voltage true-rms |
No | 600 V | 1 V | ±(3% + 3 counts) 45 Hz - 66 Hz[2] [3] |
FieldSense ac current true-rms |
No | 200.0 A | 0.1 A | ±(3% + 3 counts) 45 Hz - 66 Hz |
FieldSense frequency (Hz) |
No | 1 Hz | ±(1% + 2 counts)[3] | |
Volts ac true-rms | Yes | 600 V | 1 V | ±(1.5% + 2 counts) 45 Hz - 66 Hz |
Volts dc | Yes | 600 V | 1 V | ±(1% + 2 counts) |
Resistance | Yes | 2000 Ω | 1 Ω | ±(1% + 2 counts) |
Safety | 600 V CAT III | |||
Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding. Accuracy[2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground. Accuracy[3]: FieldSense is specified from 16 V to 100 % of range. |
What's in the Box
Includes:
- Attached test leads with removable 4 mm probe caps, user documentation