Fluke T6-1000PRO Electrical Tester
Product Description
- Simultaneous voltage and current display - save time by seeing voltage and current measurements at the same time when trouble shooting motors, pumps or other equipment
- Visual Continuity™ - When checking continuity, the screen automatically turns green while the beeper is on. Perfect for those times when it's too loud to hear the beeper, when you're wearing ear protection or when it's too dark to easily read the screen. Visual Continuity takes the guesswork out of checking continuity
- FieldSense™ technology for AC voltage, current and frequency measurement without making electrical contact to live voltage
Overview
Measure voltage … without test leads
We know working in electrical boxes jammed with wires can be challenging when you’re trying to find a safe metallic contact point. Now, with Fluke’s T6-600 or T6-1000 with integrated FieldSense technology, you can quickly and easily take measurements by sliding the open fork over a conductor to see the voltage level without the need for test leads.*
Why use the T6 Electrical Tester?
Electricians often work in boxes jammed with wires, where finding a safe metallic contact point can be a challenge. With the T6-600 or T6-1000 you take measurements by sliding a single wire into the open fork.
How FieldSense Works
FieldSense technology is truly a breakthrough in how voltage is measured. While other open fork testers detect a magnetic field to show ac current, FieldSense technology detects an electrical field. This field interacts with a reference signal created by the T6 tester, creating a voltage value on the tester’s display.
Specifications
Fluke T6-1000PRO/AMER Specifications
Measurement Specifications | |
FieldSense AC Voltage | Requires test leads: Yes, black lead Range: 1000 V Resolution: 1 V Accuracy: ±(3% + 3 counts), 45 to 66 Hz |
AC Current | Requires test leads: No Range: 200 A Resolution: 0.1 A Accuracy: ±(3% + 3 counts), 45 to 66 Hz |
FieldSense Frequency (Hz) | Requires test leads: No Range: 45 to 66 Hz Resolution: 1 Hz Accuracy: ±(1% + 2 counts) |
Volts AC | Requires test leads: Yes Range: 1000 V Resolution: 1 V Accuracy: ±(1.5% + 2 counts), 45 to 66 Hz |
Volts DC | Requires test leads: Yes Range: 1000 V Resolution: 1 V Accuracy: ±(1% + 2 counts) |
Resistance | Requires test leads: Yes Range: 2000 Ω, 20 kΩ, 100 kΩ Resolution: 1 Ω, 0.01 kΩ, 0.1 kΩ Accuracy: ±(1% + 2 counts) |
What's in the Box
Includes:
- Attached test leads with removable 4 mm probe caps
- User documentation