Power Quality

AEMC 8345 PowerPad IV Power Quality Analyzer

Power Quality

From $12,873.00 CAD
{"id":7984806002878,"title":"AEMC 8345 PowerPad IV Power Quality Analyzer","handle":"aemc-8345-powerpad-iv-power-quality-analyzer","description":"\u003cp\u003eThe PowerPad\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003emodel 8345 is a portable three-phase, Class A Power Quality Analyzer that enables technicians and engineers to measure and perform diagnostics and power quality work on one, two or three phase networks. This very advanced event recorder meets the highest performance and measurement time accuracy requirements providing a large number of calculated values and processing functions to make installations and maintenance easier.\u003c\/p\u003e\n\u003cp\u003eThis power and energy analyzer allows the measurement of voltage, current, frequency, etc. The display of the curves is completely automatic and goes up to 10 complete cycles. All power and energy measurements, and other associated parameters, necessary for a good analysis of an electrical installation in terms of its energy efficiency, are carried out according to the IEEE1459 standard.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHarmonics and interharmonics are calculated according to IEC 61000-4-7. It also includes the possibility to detect and measure main signaling (MSV). The flicker measurements comply with IEC61000-4-15. Its Trend mode allows all parameters to be recorded every 200 ms. The Alarm mode adds the ability to monitor the power system and send Emails to the user. The 10-period transient mode, now with the ability to program the number of transients prior to triggering, captures very fast events (up to 2.5 μs). In addition, it incorporates a surge mode that measures 500 ns peaks up to 12 kV. We still have the Inrush mode which captures electrical signals during load start-up.\u003c\/p\u003e\n\u003cp\u003eCommunication options are vast through USB link, Wi-Fi mode (direct or via a server), and an Ethernet RJ45 link. A VNC mode has been integrated into the device, which allows any browser (through an IP address) to control the device remotely, whether using a PC, a smartphone, or a tablet (Android or iOS). Its memory card is directly accessible on the front of the device and can be duplicated on a USB key.\u003c\/p\u003e\n\u003cp\u003eModel 8345 is compatible with all the current sensors from the PowerPad® family and comes with a power adapter for its 1000 V AC\/DC phase power supply.\u003c\/p\u003e\n\u003cp\u003eOur proprietary DataView® software is included with the meter to download and analyze all measurements. It also allows the unit to be configured for recording to EN50160.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel 8345 - Cat. #2136.35:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIncludes meter, extra-large tool bag, internal carrying pouch, hand strap, USB cable, five 10 ft black voltage leads with alligator clips, twelve color-coded input ID markers, power adapter (PA32ER) with US power cord, two 6 ft stackable leads, two 10 ft black voltage leads with alligator clips for power adapter PA32ER, SD Card, one power plug adaptor for PA32ER, 5.8 A·h Li-ion battery pack, quick start guide, and USB stick with DataView® software and user manual.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel 8345 (w\/4 MA194-24-BK Sensors) - Cat. #2136.36: \u003c\/strong\u003e\u003c\/span\u003eIncludes meter, extra-large tool bag, internal carrying pouch, hand strap, four MA194-24-BK sensors, USB cable, five 10 ft black voltage leads with alligator clips, twelve color-coded input ID markers, power adapter (PA32ER) with US power cord, two 6 ft stackable leads, two 10 ft black voltage leads with alligator clips for power adapter PA32ER, SD Card, one power plug adaptor for PA32ER,5.8 A·h Li-ion battery pack, quick start guide, and USB stick with DataView® software and user manual.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel 8345 (w\/4 193-24-BK Sensors) - Cat. #2136.37: \u003c\/strong\u003e\u003c\/span\u003eIncludes meter, extra-large tool bag, internal carrying pouch, hand strap, four 193-24-BK sensors, USB cable, five 10 ft black voltage leads with alligator clips, twelve color-coded input ID markers, power adapter (PA32ER) with US power cord, two 6 ft stackable leads, two 10 ft black voltage leads with alligator clips for power adapter PA32ER, SD Card, one power plug adaptor for PA32ER,5.8 A·h Li-ion battery pack, quick start guide, and USB stick with DataView® software and user manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_8345_Power_Quality_Model_2136-35.pdf?v=1711992599\" target=\"_blank\" title=\"AEMC 8345 Spec Sheet\" rel=\"noopener\"\u003eAEMC 8345 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2024-04-01T10:27:56-06:00","created_at":"2024-04-01T10:27:57-06:00","vendor":"AEMC Instruments","type":"Power Quality","tags":[],"price":1287300,"price_min":1287300,"price_max":1440600,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":43786027761854,"title":"2136.35","option1":"2136.35","option2":null,"option3":null,"sku":"AEMC-2136.35","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 8345 PowerPad IV Power Quality Analyzer - 2136.35","public_title":"2136.35","options":["2136.35"],"price":1287300,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":43786027794622,"title":"2136.36","option1":"2136.36","option2":null,"option3":null,"sku":"AEMC-2136.36","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 8345 PowerPad IV Power Quality Analyzer - 2136.36","public_title":"2136.36","options":["2136.36"],"price":1440600,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/files\/AEMC8345Pic1.png?v=1711992375","\/\/kingswayinstruments.com\/cdn\/shop\/files\/AEMC8345Pic2.jpg?v=1711992382"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/AEMC8345Pic1.png?v=1711992375","options":["Model"],"media":[{"alt":null,"id":27303756333246,"position":1,"preview_image":{"aspect_ratio":0.826,"height":3553,"width":2935,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/AEMC8345Pic1.png?v=1711992375"},"aspect_ratio":0.826,"height":3553,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/AEMC8345Pic1.png?v=1711992375","width":2935},{"alt":null,"id":27303756726462,"position":2,"preview_image":{"aspect_ratio":1.76,"height":712,"width":1253,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/AEMC8345Pic2.jpg?v=1711992382"},"aspect_ratio":1.76,"height":712,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/AEMC8345Pic2.jpg?v=1711992382","width":1253}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe PowerPad\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003emodel 8345 is a portable three-phase, Class A Power Quality Analyzer that enables technicians and engineers to measure and perform diagnostics and power quality work on one, two or three phase networks. This very advanced event recorder meets the highest performance and measurement time accuracy requirements providing a large number of calculated values and processing functions to make installations and maintenance easier.\u003c\/p\u003e\n\u003cp\u003eThis power and energy analyzer allows the measurement of voltage, current, frequency, etc. The display of the curves is completely automatic and goes up to 10 complete cycles. All power and energy measurements, and other associated parameters, necessary for a good analysis of an electrical installation in terms of its energy efficiency, are carried out according to the IEEE1459 standard.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHarmonics and interharmonics are calculated according to IEC 61000-4-7. It also includes the possibility to detect and measure main signaling (MSV). The flicker measurements comply with IEC61000-4-15. Its Trend mode allows all parameters to be recorded every 200 ms. The Alarm mode adds the ability to monitor the power system and send Emails to the user. The 10-period transient mode, now with the ability to program the number of transients prior to triggering, captures very fast events (up to 2.5 μs). In addition, it incorporates a surge mode that measures 500 ns peaks up to 12 kV. We still have the Inrush mode which captures electrical signals during load start-up.\u003c\/p\u003e\n\u003cp\u003eCommunication options are vast through USB link, Wi-Fi mode (direct or via a server), and an Ethernet RJ45 link. A VNC mode has been integrated into the device, which allows any browser (through an IP address) to control the device remotely, whether using a PC, a smartphone, or a tablet (Android or iOS). Its memory card is directly accessible on the front of the device and can be duplicated on a USB key.\u003c\/p\u003e\n\u003cp\u003eModel 8345 is compatible with all the current sensors from the PowerPad® family and comes with a power adapter for its 1000 V AC\/DC phase power supply.\u003c\/p\u003e\n\u003cp\u003eOur proprietary DataView® software is included with the meter to download and analyze all measurements. It also allows the unit to be configured for recording to EN50160.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel 8345 - Cat. #2136.35:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIncludes meter, extra-large tool bag, internal carrying pouch, hand strap, USB cable, five 10 ft black voltage leads with alligator clips, twelve color-coded input ID markers, power adapter (PA32ER) with US power cord, two 6 ft stackable leads, two 10 ft black voltage leads with alligator clips for power adapter PA32ER, SD Card, one power plug adaptor for PA32ER, 5.8 A·h Li-ion battery pack, quick start guide, and USB stick with DataView® software and user manual.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel 8345 (w\/4 MA194-24-BK Sensors) - Cat. #2136.36: \u003c\/strong\u003e\u003c\/span\u003eIncludes meter, extra-large tool bag, internal carrying pouch, hand strap, four MA194-24-BK sensors, USB cable, five 10 ft black voltage leads with alligator clips, twelve color-coded input ID markers, power adapter (PA32ER) with US power cord, two 6 ft stackable leads, two 10 ft black voltage leads with alligator clips for power adapter PA32ER, SD Card, one power plug adaptor for PA32ER,5.8 A·h Li-ion battery pack, quick start guide, and USB stick with DataView® software and user manual.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel 8345 (w\/4 193-24-BK Sensors) - Cat. #2136.37: \u003c\/strong\u003e\u003c\/span\u003eIncludes meter, extra-large tool bag, internal carrying pouch, hand strap, four 193-24-BK sensors, USB cable, five 10 ft black voltage leads with alligator clips, twelve color-coded input ID markers, power adapter (PA32ER) with US power cord, two 6 ft stackable leads, two 10 ft black voltage leads with alligator clips for power adapter PA32ER, SD Card, one power plug adaptor for PA32ER,5.8 A·h Li-ion battery pack, quick start guide, and USB stick with DataView® software and user manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_8345_Power_Quality_Model_2136-35.pdf?v=1711992599\" target=\"_blank\" title=\"AEMC 8345 Spec Sheet\" rel=\"noopener\"\u003eAEMC 8345 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 8345 PowerPad IV Power Quality Analyzer

AEMC 8345 PowerPad IV Power Quality Analyzer

$14,406.00 CAD

The PowerPad® model 8345 is a portable three-phase, Class A Power Quality Analyzer that enables technicians and engineers to measure and perform diagnostics and power quality work on one, two or three phase networks. This very advanced event recorder meets the highest performance and measurement time accuracy requirements providing a large numbe...


More Info
Fluke 1770 Series Three-Phase Power Quality Analyzers

Power Quality

From $11,527.35 CAD
{"id":7015265566910,"title":"Fluke 1770 Series Three-Phase Power Quality Analyzers","handle":"fluke-1770-series-three-phase-power-quality-analyzers","description":"\u003ch3\u003eAutomatic measurements. More flexibility. Better power quality troubleshooting.\u003c\/h3\u003e\n\u003cp\u003eReplacing the long standing Fluke 430 Series, the Fluke 1770 Series Three-Phase Power Quality Analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series offers automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord\u003c\/p\u003e\n\u003cp\u003eWith the 1770 Series you’ll never miss a critical power quality event—from fast transients up to 8 kV, harmonics up to 30 kHz, dips and swells, as well as the voltage, current, and power measurements that enable you to characterize your electrical system.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2\u003eAutomatic Measurement capture\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cdiv class=\"container-flex col-reverse\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eWhether you’re performing a quick system check or a detailed power quality study, consistent data is key. The Fluke 1770 Series offers a unique automatic measurement capture system that helps ensure you’re collecting the right data every time, while still giving you the flexibility to select and adjust specific parameters as needed. More than 500 power quality parameters are captured by default and the guided setup makes it easy to select the right parameters for the system you’re working on. Logged data is instantly viewable, downloadable, and shareable with Fluke Energy Analyze Plus software so you never need to wait to finish a session before reviewing results or analyzing data.\u003c\/p\u003e\n\u003ch3\u003eUltimate measurement confidence\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1770 Series are 2-in-1 devices that combine the troubleshooting functionality of a power quality meter with the robust analysis and logging capabilities of a standalone power quality analyzer—in a single, easy-to-use, handheld device.\u003c\/p\u003e\n\u003cp\u003eThe ‘PQ Meter’ function gives you immediate access to live onscreen data in the field so you can quickly identify potential problems while troubleshooting. The detailed ‘PQ Logging and Analysis’ function eliminates the complexity of performing power quality studies by guiding you through the setup process ensuring you’re capturing the right data every time. Couple these measurement modes with a unique measurement connection autocorrect function and you can be confident that you never need to worry about going back for a second measurement—even if you were unsure about what to look for when you started.\u003c\/p\u003e\n\u003ch3\u003eHigh-speed voltage transient capture\u003c\/h3\u003e\n\u003cp\u003eTransients negatively impact otherwise healthy systems every day and their potential to damage your equipment can’t be underestimated. Whether your system is experiencing impulsive or oscillatory transients, the results can be devastating and cause problems ranging from insulation failures to total equipment failures. The Fluke 1775 and Fluke 1777 incorporate advanced transient capture technology to help you clearly identify high-speed voltage transients, so you have the data you need to stop them in their tracks. The Fluke 1775 Power Quality Analyzer has 1MHz sampling capability to capture fast transients, while the Fluke 1777 Power Quality Analyzer has 20MHz sampling capability to capture the fastest transients in high detail.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\" itemprop=\"name\"\u003e\u003cstrong\u003eFluke 1773 Three-Phase Power Quality Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1773 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eI17XX-FLEX1500 24 iFLEX 1500A 24 IN (2.0M) current probes (set of four)\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clips (set of four)\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1M USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cords (US, EU, UK, AUS, BRA)\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eFLUKE-177X-4204, WI-FI\/BLE module\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cstrong\u003eFluke 1775 Three-Phase Power Quality Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1775 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eI17XX-FLEX1500 24 iFLEX 1500A 24 IN (2.0M) current probes (set of four)\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clips (set of four)\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1m USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cord\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eMP1-3R\/1B Magnet Probe set\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-HANGER magnetic hanging kit\u003c\/li\u003e\n\u003cli\u003eFLUKE-177X-4204, WI-FI\/BLE module\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003cli\u003eBlack soft case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cstrong\u003eFluke 1777\u003cspan\u003e \u003c\/span\u003eThree-Phase Power Quality Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1775 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eI17XX-FLEX1500 24 iFLEX 1500A 24 IN (2.0M) current probes (set of four)\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clips (set of four)\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1m USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cord\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eMP1-3R\/1B Magnet Probe set\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-HANGER magnetic hanging kit\u003c\/li\u003e\n\u003cli\u003eFLUKE-177X-4204, WI-FI\/BLE module\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003cli\u003eBlack soft case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1770_Series_Power_Quality_Analyzer_Datasheet.pdf?v=1636404123\" target=\"_blank\" title=\"Fluke 1770 Series Power Quality Datasheet\" rel=\"noopener noreferrer\"\u003eFluke 1770 Series Power Quality Datasheet\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e","published_at":"2021-10-14T12:47:42-06:00","created_at":"2021-10-14T12:47:42-06:00","vendor":"Fluke","type":"Power Quality","tags":[],"price":1152735,"price_min":1152735,"price_max":1892847,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":40814254194878,"title":"Fluke 1775","option1":"Fluke 1775","option2":null,"option3":null,"sku":"FLU-1775","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1770 Series Three-Phase Power Quality Analyzers - Fluke 1775","public_title":"Fluke 1775","options":["Fluke 1775"],"price":1514631,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969917674","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":40814254227646,"title":"Fluke 1777","option1":"Fluke 1777","option2":null,"option3":null,"sku":"FLU-1777","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1770 Series Three-Phase Power Quality Analyzers - Fluke 1777","public_title":"Fluke 1777","options":["Fluke 1777"],"price":1892847,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969919012","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":40814254260414,"title":"Fluke 1773","option1":"Fluke 1773","option2":null,"option3":null,"sku":"FLU-1773","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1770 Series Three-Phase Power Quality Analyzers - Fluke 1773","public_title":"Fluke 1773","options":["Fluke 1773"],"price":1152735,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969917667","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke1770SeriesPic1.jpg?v=1634238100"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke1770SeriesPic1.jpg?v=1634238100","options":["Model"],"media":[{"alt":null,"id":22427520270526,"position":1,"preview_image":{"aspect_ratio":1.448,"height":411,"width":595,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke1770SeriesPic1.jpg?v=1634238100"},"aspect_ratio":1.448,"height":411,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke1770SeriesPic1.jpg?v=1634238100","width":595}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eAutomatic measurements. More flexibility. Better power quality troubleshooting.\u003c\/h3\u003e\n\u003cp\u003eReplacing the long standing Fluke 430 Series, the Fluke 1770 Series Three-Phase Power Quality Analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series offers automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord\u003c\/p\u003e\n\u003cp\u003eWith the 1770 Series you’ll never miss a critical power quality event—from fast transients up to 8 kV, harmonics up to 30 kHz, dips and swells, as well as the voltage, current, and power measurements that enable you to characterize your electrical system.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2\u003eAutomatic Measurement capture\u003c\/h2\u003e\n\u003cdiv id=\"fluke-product-display-overview\"\u003e\n\u003cdiv id=\"product-overview\"\u003e\n\u003cdiv id=\"overview_content\" itemprop=\"description\"\u003e\n\u003cdiv class=\"container-flex col-reverse\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eWhether you’re performing a quick system check or a detailed power quality study, consistent data is key. The Fluke 1770 Series offers a unique automatic measurement capture system that helps ensure you’re collecting the right data every time, while still giving you the flexibility to select and adjust specific parameters as needed. More than 500 power quality parameters are captured by default and the guided setup makes it easy to select the right parameters for the system you’re working on. Logged data is instantly viewable, downloadable, and shareable with Fluke Energy Analyze Plus software so you never need to wait to finish a session before reviewing results or analyzing data.\u003c\/p\u003e\n\u003ch3\u003eUltimate measurement confidence\u003c\/h3\u003e\n\u003cp\u003eThe Fluke 1770 Series are 2-in-1 devices that combine the troubleshooting functionality of a power quality meter with the robust analysis and logging capabilities of a standalone power quality analyzer—in a single, easy-to-use, handheld device.\u003c\/p\u003e\n\u003cp\u003eThe ‘PQ Meter’ function gives you immediate access to live onscreen data in the field so you can quickly identify potential problems while troubleshooting. The detailed ‘PQ Logging and Analysis’ function eliminates the complexity of performing power quality studies by guiding you through the setup process ensuring you’re capturing the right data every time. Couple these measurement modes with a unique measurement connection autocorrect function and you can be confident that you never need to worry about going back for a second measurement—even if you were unsure about what to look for when you started.\u003c\/p\u003e\n\u003ch3\u003eHigh-speed voltage transient capture\u003c\/h3\u003e\n\u003cp\u003eTransients negatively impact otherwise healthy systems every day and their potential to damage your equipment can’t be underestimated. Whether your system is experiencing impulsive or oscillatory transients, the results can be devastating and cause problems ranging from insulation failures to total equipment failures. The Fluke 1775 and Fluke 1777 incorporate advanced transient capture technology to help you clearly identify high-speed voltage transients, so you have the data you need to stop them in their tracks. The Fluke 1775 Power Quality Analyzer has 1MHz sampling capability to capture fast transients, while the Fluke 1777 Power Quality Analyzer has 20MHz sampling capability to capture the fastest transients in high detail.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\" itemprop=\"name\"\u003e\u003cstrong\u003eFluke 1773 Three-Phase Power Quality Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1773 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eI17XX-FLEX1500 24 iFLEX 1500A 24 IN (2.0M) current probes (set of four)\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clips (set of four)\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1M USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cords (US, EU, UK, AUS, BRA)\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eFLUKE-177X-4204, WI-FI\/BLE module\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cstrong\u003eFluke 1775 Three-Phase Power Quality Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1775 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eI17XX-FLEX1500 24 iFLEX 1500A 24 IN (2.0M) current probes (set of four)\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clips (set of four)\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1m USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cord\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eMP1-3R\/1B Magnet Probe set\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-HANGER magnetic hanging kit\u003c\/li\u003e\n\u003cli\u003eFLUKE-177X-4204, WI-FI\/BLE module\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003cli\u003eBlack soft case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cstrong\u003eFluke 1777\u003cspan\u003e \u003c\/span\u003eThree-Phase Power Quality Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFLUKE-1775 Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003eI17XX-FLEX1500 24 iFLEX 1500A 24 IN (2.0M) current probes (set of four)\u003c\/li\u003e\n\u003cli\u003eFLUKE-17XX flat cable voltage test lead 3-phase+N\u003c\/li\u003e\n\u003cli\u003eAC285 black alligator clips (set of four)\u003c\/li\u003e\n\u003cli\u003eAC285 green alligator clip\u003c\/li\u003e\n\u003cli\u003eBlack 1m USB-C cable\u003c\/li\u003e\n\u003cli\u003eLine cord\u003c\/li\u003e\n\u003cli\u003eFLK-17XX 0.18M test lead set\u003c\/li\u003e\n\u003cli\u003eGreen test lead\u003c\/li\u003e\n\u003cli\u003eMP1-3R\/1B Magnet Probe set\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-HANGER magnetic hanging kit\u003c\/li\u003e\n\u003cli\u003eFLUKE-177X-4204, WI-FI\/BLE module\u003c\/li\u003e\n\u003cli\u003eCable marker set (for voltage and current)\u003c\/li\u003e\n\u003cli\u003eFLUKE-174X-MA-C8 wall outlet adapter\u003c\/li\u003e\n\u003cli\u003eBlack soft case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1770_Series_Power_Quality_Analyzer_Datasheet.pdf?v=1636404123\" target=\"_blank\" title=\"Fluke 1770 Series Power Quality Datasheet\" rel=\"noopener noreferrer\"\u003eFluke 1770 Series Power Quality Datasheet\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e"}
Fluke 1770 Series Three-Phase Power Quality Analyzers

Fluke 1770 Series Three-Phase Power Quality Analyzers

$11,527.35 CAD

Automatic measurements. More flexibility. Better power quality troubleshooting. Replacing the long standing Fluke 430 Series, the Fluke 1770 Series Three-Phase Power Quality Analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1...


More Info
{"id":6179840327870,"title":"AEMC 8336 PowerPad III Power Quality Analyzer with AmpFlex Sensors, 24\"","handle":"aemc-8336-powerpad-iii-power-quality-analyzer-with-ampflex-sensors-24","description":"\u003cp\u003eThe PowerPad\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIII Model 8336 is a three-phase power quality analyzer that is easy-to-use, compact and shock resistant. It enables technicians and engineers to measure and carry out diagnostics and power quality work on one-, two- or three- phase networks. Five voltage and four current inputs are provided. It is IEC 61000-4-30 Class B and safety rated to 600V CAT IV.\u003c\/p\u003e\n\u003cp\u003eThe Model 8336 has 2GB of memory available for storing trend data. Additional internal memory is used to let you store alarms, transients, and snapshot data. The user can store up to 50 screen snapshots, up to 210 captured transients that contain four cycles for each active input, and 10,000 alarm events from up to 40 different parameters. Trend data can also be recorded for days, weeks or even months. Inrush current can also be captured and stored.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIMPORTANT WARRANTY NOTE: By registering online within 30 days from the date of purchase, your warranty will be extended to 3 years.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of TRMS voltages up to 1000Vrms AD\/DC for two-, three-, four- or five-wire systems\u003c\/li\u003e\n\u003cli\u003eMeasurement of TRMS currents up to 10kArms (sensor dependent)\u003c\/li\u003e\n\u003cli\u003eMeasures up to 5000ADC with the AC\/DC Current Probe Model J93\u003c\/li\u003e\n\u003cli\u003eFrequency measurement (40 to 70Hz systems)\u003c\/li\u003e\n\u003cli\u003eRecords and displays trend data as fast as once per second for one month up to 41 variables\u003c\/li\u003e\n\u003cli\u003eCaptures up to 210 transient occurrences on all V and A inputs\u003c\/li\u003e\n\u003cli\u003eMeasures harmonics (referenced to the fundamental or RMS value) for voltage, current or power up to the 50th harmonic\u003c\/li\u003e\n\u003cli\u003eRecording, time stamping and characterization of disturbance (swells, sages and interruptions, exceedance of power and harmonic thresholds)\u003c\/li\u003e\n\u003cli\u003e2GB SD Card for Trend Recording memory; Alarm, Snapshot, Transient and Inrush stored in internal flash memory\u003c\/li\u003e\n\u003cli\u003eMeasures energy VAh, VARh \u0026amp; Wh\u003c\/li\u003e\n\u003cli\u003e65\u0026amp;micrp;s\/sample transient recording\u003c\/li\u003e\n\u003cli\u003eFREE DataView® software is included for configuring real-time display and report generation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Terminals\u003c\/td\u003e\n\u003ctd\u003e5 voltage \/ 4 current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e4 voltage \/ 4 current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage (TRMS AC+DC)\u003c\/td\u003e\n\u003ctd\u003e2 to 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Ratio\u003c\/td\u003e\n\u003ctd\u003eUp to 500kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent (TRMS AC+DC)\u003c\/td\u003e\n\u003ctd\u003eMN93: 500mA to 200A AC\u003cbr\u003eMN193: 0.005 to 100A AC\u003cbr\u003eSR193 Clamp: 1A to 1000A AC\u003cbr\u003eAmpFlex ® or MA193 Clamps: 100mA to 10000A AC\u003cbr\u003eMR193 Clamp: 1A to 1300A AC\/DC\u003cbr\u003eSL261 Clamp: 50mA to 100A AC\/DC\u003cbr\u003eCurrent Ratio: up to 60kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e40 to 69Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistribution Systems\u003c\/td\u003e\n\u003ctd\u003e1P 2W, 1P 3W, 2P 2W, 2P 3W, 2P 4W, 3P 3W, 3P 4W\u003cbr\u003eand 3p 5W, 2 1\/2 Element \u0026amp; Aron meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Values\u003c\/td\u003e\n\u003ctd\u003eW, VA, var, VAD, PF, DPF, cos Φ, tan Φ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Values\u003c\/td\u003e\n\u003ctd\u003eWh, VARh, VAh, VADh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonics\u003c\/td\u003e\n\u003ctd\u003e1st to 50th, Direction, Sequence\u003cbr\u003eTHD: 0 to 50, phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransients\u003c\/td\u003e\n\u003ctd\u003eup to 210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlicker (Pst \u0026amp; Plt)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Mode\u003c\/td\u003e\n\u003ctd\u003eYes, \u0026gt;10 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnbalance\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Mode\u003c\/td\u003e\n\u003ctd\u003e40 types; 10,000 recorded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhasor Display\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eColor 1\/4 VGA TFT screen (320 x 240) diagonal 148mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSnapshots\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010, 1000V CAT III \/ 600V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eIP50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eMore than 27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;13 hrs, 25 hrs in Record Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e9.6V NiMH rechargeable battery pack (included)\u003cbr\u003eExternal AC supply: 110\/230V AC ±10% (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions \/ Weight\u003c\/td\u003e\n\u003ctd\u003e9.8 x 7.8 x 2.6\" (240 x 180 x 55mm) \/ 4.3 lbs (1.95kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePowerPad III Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003e3 x 24\" AmpFlex Flexible Sensors\u003c\/li\u003e\n\u003cli\u003e5ft USB Cable\u003c\/li\u003e\n\u003cli\u003e4 x 10ft Black Voltage Leads with Alligator Clips\u003c\/li\u003e\n\u003cli\u003e12 x Color-Coded Input ID Markers\u003c\/li\u003e\n\u003cli\u003ePower Adapter\u003c\/li\u003e\n\u003cli\u003eSD-Card\u003c\/li\u003e\n\u003cli\u003eExtra Large Tool Bag\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Pouch\u003c\/li\u003e\n\u003cli\u003e9.6V NiMH Battery\u003c\/li\u003e\n\u003cli\u003eQuick Start Guide\u003c\/li\u003e\n\u003cli\u003eUSB Stick containing DataView Software and Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca title=\"AEMC 8336 PowerPad III Power Quality Analyzer Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_8333-8336_-_2136-30.pdf?v=1611002748\" target=\"_blank\"\u003eAEMC 8336 PowerPad III Power Quality Analyzer Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-18T13:46:41-07:00","created_at":"2021-01-18T13:46:40-07:00","vendor":"AEMC Instruments","type":"Power Quality","tags":[],"price":927500,"price_min":927500,"price_max":927500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37912398790846,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2136.31","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC 8336 PowerPad III Power Quality Analyzer with AmpFlex Sensors, 24\"","public_title":null,"options":["Default Title"],"price":927500,"weight":10433,"compare_at_price":null,"inventory_management":"shopify","barcode":"685338220568","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC8336Pic1.png?v=1611002802","\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC8336Pic2.png?v=1611002803","\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC8336Pic3.png?v=1611002803","\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC8336Pic4.png?v=1611002803"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC8336Pic1.png?v=1611002802","options":["Title"],"media":[{"alt":null,"id":15455596413118,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC8336Pic1.png?v=1611002802"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC8336Pic1.png?v=1611002802","width":650},{"alt":null,"id":15455596445886,"position":2,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC8336Pic2.png?v=1611002803"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC8336Pic2.png?v=1611002803","width":650},{"alt":null,"id":15455596478654,"position":3,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC8336Pic3.png?v=1611002803"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC8336Pic3.png?v=1611002803","width":650},{"alt":null,"id":15455596511422,"position":4,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC8336Pic4.png?v=1611002803"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC8336Pic4.png?v=1611002803","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe PowerPad\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eIII Model 8336 is a three-phase power quality analyzer that is easy-to-use, compact and shock resistant. It enables technicians and engineers to measure and carry out diagnostics and power quality work on one-, two- or three- phase networks. Five voltage and four current inputs are provided. It is IEC 61000-4-30 Class B and safety rated to 600V CAT IV.\u003c\/p\u003e\n\u003cp\u003eThe Model 8336 has 2GB of memory available for storing trend data. Additional internal memory is used to let you store alarms, transients, and snapshot data. The user can store up to 50 screen snapshots, up to 210 captured transients that contain four cycles for each active input, and 10,000 alarm events from up to 40 different parameters. Trend data can also be recorded for days, weeks or even months. Inrush current can also be captured and stored.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIMPORTANT WARRANTY NOTE: By registering online within 30 days from the date of purchase, your warranty will be extended to 3 years.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of TRMS voltages up to 1000Vrms AD\/DC for two-, three-, four- or five-wire systems\u003c\/li\u003e\n\u003cli\u003eMeasurement of TRMS currents up to 10kArms (sensor dependent)\u003c\/li\u003e\n\u003cli\u003eMeasures up to 5000ADC with the AC\/DC Current Probe Model J93\u003c\/li\u003e\n\u003cli\u003eFrequency measurement (40 to 70Hz systems)\u003c\/li\u003e\n\u003cli\u003eRecords and displays trend data as fast as once per second for one month up to 41 variables\u003c\/li\u003e\n\u003cli\u003eCaptures up to 210 transient occurrences on all V and A inputs\u003c\/li\u003e\n\u003cli\u003eMeasures harmonics (referenced to the fundamental or RMS value) for voltage, current or power up to the 50th harmonic\u003c\/li\u003e\n\u003cli\u003eRecording, time stamping and characterization of disturbance (swells, sages and interruptions, exceedance of power and harmonic thresholds)\u003c\/li\u003e\n\u003cli\u003e2GB SD Card for Trend Recording memory; Alarm, Snapshot, Transient and Inrush stored in internal flash memory\u003c\/li\u003e\n\u003cli\u003eMeasures energy VAh, VARh \u0026amp; Wh\u003c\/li\u003e\n\u003cli\u003e65\u0026amp;micrp;s\/sample transient recording\u003c\/li\u003e\n\u003cli\u003eFREE DataView® software is included for configuring real-time display and report generation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Terminals\u003c\/td\u003e\n\u003ctd\u003e5 voltage \/ 4 current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e4 voltage \/ 4 current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage (TRMS AC+DC)\u003c\/td\u003e\n\u003ctd\u003e2 to 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Ratio\u003c\/td\u003e\n\u003ctd\u003eUp to 500kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent (TRMS AC+DC)\u003c\/td\u003e\n\u003ctd\u003eMN93: 500mA to 200A AC\u003cbr\u003eMN193: 0.005 to 100A AC\u003cbr\u003eSR193 Clamp: 1A to 1000A AC\u003cbr\u003eAmpFlex ® or MA193 Clamps: 100mA to 10000A AC\u003cbr\u003eMR193 Clamp: 1A to 1300A AC\/DC\u003cbr\u003eSL261 Clamp: 50mA to 100A AC\/DC\u003cbr\u003eCurrent Ratio: up to 60kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency (Hz)\u003c\/td\u003e\n\u003ctd\u003e40 to 69Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistribution Systems\u003c\/td\u003e\n\u003ctd\u003e1P 2W, 1P 3W, 2P 2W, 2P 3W, 2P 4W, 3P 3W, 3P 4W\u003cbr\u003eand 3p 5W, 2 1\/2 Element \u0026amp; Aron meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Values\u003c\/td\u003e\n\u003ctd\u003eW, VA, var, VAD, PF, DPF, cos Φ, tan Φ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Values\u003c\/td\u003e\n\u003ctd\u003eWh, VARh, VAh, VADh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonics\u003c\/td\u003e\n\u003ctd\u003e1st to 50th, Direction, Sequence\u003cbr\u003eTHD: 0 to 50, phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransients\u003c\/td\u003e\n\u003ctd\u003eup to 210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlicker (Pst \u0026amp; Plt)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Mode\u003c\/td\u003e\n\u003ctd\u003eYes, \u0026gt;10 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnbalance\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Mode\u003c\/td\u003e\n\u003ctd\u003e40 types; 10,000 recorded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhasor Display\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eColor 1\/4 VGA TFT screen (320 x 240) diagonal 148mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSnapshots\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eIEC 61010, 1000V CAT III \/ 600V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eIP50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eMore than 27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;13 hrs, 25 hrs in Record Mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e9.6V NiMH rechargeable battery pack (included)\u003cbr\u003eExternal AC supply: 110\/230V AC ±10% (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions \/ Weight\u003c\/td\u003e\n\u003ctd\u003e9.8 x 7.8 x 2.6\" (240 x 180 x 55mm) \/ 4.3 lbs (1.95kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePowerPad III Power Quality Analyzer\u003c\/li\u003e\n\u003cli\u003e3 x 24\" AmpFlex Flexible Sensors\u003c\/li\u003e\n\u003cli\u003e5ft USB Cable\u003c\/li\u003e\n\u003cli\u003e4 x 10ft Black Voltage Leads with Alligator Clips\u003c\/li\u003e\n\u003cli\u003e12 x Color-Coded Input ID Markers\u003c\/li\u003e\n\u003cli\u003ePower Adapter\u003c\/li\u003e\n\u003cli\u003eSD-Card\u003c\/li\u003e\n\u003cli\u003eExtra Large Tool Bag\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Pouch\u003c\/li\u003e\n\u003cli\u003e9.6V NiMH Battery\u003c\/li\u003e\n\u003cli\u003eQuick Start Guide\u003c\/li\u003e\n\u003cli\u003eUSB Stick containing DataView Software and Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca title=\"AEMC 8336 PowerPad III Power Quality Analyzer Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_8333-8336_-_2136-30.pdf?v=1611002748\" target=\"_blank\"\u003eAEMC 8336 PowerPad III Power Quality Analyzer Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC 8336 PowerPad III Power Quality Analyzer with AmpFlex Sensors, 24"

AEMC 8336 PowerPad III Power Quality Analyzer with AmpFlex Sensors, 24"

$9,275.00 CAD

The PowerPad® III Model 8336 is a three-phase power quality analyzer that is easy-to-use, compact and shock resistant. It enables technicians and engineers to measure and carry out diagnostics and power quality work on one-, two- or three- phase networks. Five voltage and four current inputs are provided. It is IEC 61000-4-30 Class B and safety ...


More Info
{"id":6179087351998,"title":"AEMC PEL 103 Power\/Energy Data Logger Kit with LCD","handle":"aemc-pel-103-power-energy-data-logger-kit-with-lcd","description":"\u003cp\u003eThe PEL 103 is a low cost, simple to use, one, two (split phase) and three phase power\/energy data logger. This product is ideal for electricians, engineers and contractors doing work in the area of building and system monitoring and upgrades, as well as residential and overall energy audits. All vital energy data is easily measured, recorded, and analyzed. Reports can be generated with confidence with minimal configuration time and effort (Standard and Customizable Reports supplied).\u003c\/p\u003e\n\u003cp\u003eThe instrument’s design enables it to be installed inside a load center panel (including the current sensors) allowing the door to close on most panels. The PEL 100 series offers all the essential functions for logging power\/energy data from most electrical power networks in use today across the world (17 network set-ups provided). The PEL 100 series energy loggers measure and record three True RMS voltage inputs and current inputs, Watts, VARS, VA and Energy (kWh and kVA). Power Factor (PF), Displacement Power Factor (DPF), Crest Factor, Frequency and THD are calculated and recorded as well. Individual harmonic % information from 1 to the 50th harmonic are recorded at the operator’s choice. All variables are recorded and stored at a one second interval and on user selectable demand intervals from 1 to 60 minutes.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of RMS voltages and currents at 128 times per cycle and stored every second\u003c\/li\u003e\n\u003cli\u003eMeasurement of VA, W and var power values (total and per phase) stored every second\u003c\/li\u003e\n\u003cli\u003eMeasurement of VAh, Wh and varh energy values (total and per phase) per second with source\/load indication\u003c\/li\u003e\n\u003cli\u003eCalculation of the cos φ Displacement Power Factor (DPF) and the Power Factor (PF) stored every second\u003c\/li\u003e\n\u003cli\u003eCalculation of Total Harmonic Distortion (THD)\u003c\/li\u003e\n\u003cli\u003eMeasurement, calculation and display of the harmonics up to the 50th order for 50\/60 Hz and 7th order for 400Hz\u003c\/li\u003e\n\u003cli\u003eMeasurement of the DC quantities (RMS calculation)\u003c\/li\u003e\n\u003cli\u003eDisplay Measurements\u003c\/li\u003e\n\u003cli\u003eElectrical network quantities are stored on a removable SD-Card\u003c\/li\u003e\n\u003cli\u003eAutomatic recognition of the connected current sensors\u003c\/li\u003e\n\u003cli\u003eDataView software for configuration, data retrieval and real-time viewing of measurements with a PC\u003c\/li\u003e\n\u003cli\u003eCompact and rugged case\u003c\/li\u003e\n\u003cli\u003eVersatile communication interface choices built in (USB, Ethernet, Bluetooth)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003enputs \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003e3 Voltage \/ 3 Current: calculation of neutral current\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\n\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e128 per Cycle\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003e6.4kHz at 50Hz\u003c\/td\u003e\n\u003ctd width=\"222\" valign=\"top\" colspan=\"2\"\u003e7.68kHz at 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e\u003cstrong\u003eAccuracy (Typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"610\" valign=\"top\" colspan=\"6\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eVolt\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eVrms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e1000V P to N\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003e10 to 1000V\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e0.1V\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±0.2% Rdg + 0.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eUrms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e1000V P to P\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003e17 to 1700V\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e0.1V\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±0.2% Rdg + 0.4V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"610\" valign=\"top\" colspan=\"6\"\u003e\u003cstrong\u003eAmps @ 50 and 60Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\n\u003cstrong\u003eAmps (1V nominal)\u003c\/strong\u003e\u003cbr\u003e(excluding clamp accuracy\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003eProbe dependent\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e0.2%\u0026lt; I \u0026lt; 120% Inom\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003eProbe dependent\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±0.2% Rdg + 0.02% Inom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\n\u003cstrong\u003eAmpFLEX \u0026amp; MiniFlex \u003c\/strong\u003e\u003cbr\u003e(including sensor accuracy)\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003eRange 100A \u003cbr\u003eRange 400A\u003cbr\u003eRange 2kA\u003cbr\u003eRange 10kA\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e200mA to 120A\u003cbr\u003e5 to 440A\u003cbr\u003e50 to 2400A\u003cbr\u003e400A to 12kA\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e1mA\u003cbr\u003e0.1A\u003cbr\u003e0.1A \u0026amp; 1A\u003cbr\u003e1A\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±1.2% Rdg + 50mA\u003cbr\u003e±1.2% Rdg + 0.2A\u003cbr\u003e±1.2% Rdg + 1A\u003cbr\u003e±1.2% Rdg + 5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e42.5 to 69Hz\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e0.01Hz\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±0.1Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"610\" valign=\"top\" colspan=\"6\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"262\" valign=\"top\" colspan=\"2\"\u003e\u003cstrong\u003eWatts (VA, var) P-Q-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e10W to 10GW \/ 10var to 10Gvar \/ 10VA to 10GVA\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e4 digits min\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±0.5% Rdg + 0.005% Pnom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"262\" valign=\"top\" colspan=\"2\"\u003e\u003cstrong\u003ePower Factor (Cos Φ\/DPF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e-1  to 1\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e0.001\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±0.05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"610\" valign=\"top\" colspan=\"6\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eEnergy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003ekWh (kVAh, kvarh) P-Q-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"330\" valign=\"top\" colspan=\"4\"\u003eUp to 4EWh \/ 4Evarh \/ 4 EVAh (E = 1018 )\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±0.5% Rdg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eHarmonics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eDC, 1 to 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eVolts \u0026amp; Amp %\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e0.01 to 655.0%\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e0.01%\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±1% Rdg from 1 to 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eTHD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e0.00 to 655.0%\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e0.01%\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±1% Rdg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"610\" valign=\"top\" colspan=\"6\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eGeneral Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eCase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eDesign Rugged, shock proof with integrated protective holster, IP54 not included terminals. Shock and vibration IEC61010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eIsolated USB, Bluetooth, and Ethernet, SD card for direct transfer to PC. Dataview software for real time data, configuration and reporting included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003e8GB SD card (SDHC compliant, FAT32 formatted)  32GB max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eLCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eReal-Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eTime and date stamp for Trend mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eAC 110V\/230V 50\/60Hz 15VA; Battery backup when power OFF, 60 minutes typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003e10.08 x 4.92 x 1.46” (256 x 125 x 37mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003e2.2lbs (1kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eAltitude Operating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003e2000m (6560ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003e32 to 108.5°F; (0°C to +42.5°C) from 10 to 85% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003e-4 to 122°F; (-20°C to +50°C) from 0 to 75% RH with battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eElectro-Magnetic-Compatibility (EMC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eEN 61326-1 for emission and immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eIP54 per IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eIEC\/EN 61010-1 (1000V CAT III-600V CAT IV), IEC 1326-1\u003cimg src=\"https:\/\/www.aemc.com\/userfiles\/images\/logos\/ETL_Logo_CE.png\" alt=\"\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePower \u0026amp; Energy Logger Model PEL 102\u003c\/li\u003e\n\u003cli\u003e4 x Black Test Leads and Alligator Clips\u003c\/li\u003e\n\u003cli\u003e12 x Color-coded ID Markers\u003c\/li\u003e\n\u003cli\u003e3 x MA193-10-BK MiniFlex®\u003c\/li\u003e\n\u003cli\u003eSmall Classic Tool Bag\u003c\/li\u003e\n\u003cli\u003eMultifix (mounting system)\u003c\/li\u003e\n\u003cli\u003eUSB SD-Card Adapter\u003c\/li\u003e\n\u003cli\u003ePower Cord, 5 ft 115V\u003c\/li\u003e\n\u003cli\u003e5 ft USB Cable\u003c\/li\u003e\n\u003cli\u003e2 GB SD-Card\u003c\/li\u003e\n\u003cli\u003e4 GB USB Stick with DataView® Software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_PEL_103_-_2137.52_-_Power_and_Energy_Logger_Spec_Sheet.pdf?v=1610981824\" target=\"_blank\" title=\"AEMC PEL 103 Power\/Energy Data Logger Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC PEL 103 Power\/Energy Data Logger Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-01-18T08:03:38-07:00","created_at":"2021-01-18T08:03:37-07:00","vendor":"AEMC Instruments","type":"Power Quality","tags":[],"price":349300,"price_min":349300,"price_max":349300,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":37910334472382,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AEMC-2137.52","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AEMC PEL 103 Power\/Energy Data Logger Kit with LCD","public_title":null,"options":["Default Title"],"price":349300,"weight":5443,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCPEL103Pic1.png?v=1610982219","\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCPEL103Pic2.png?v=1610982219","\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCPEL103Pic3.png?v=1610982222"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCPEL103Pic1.png?v=1610982219","options":["Title"],"media":[{"alt":null,"id":15453134651582,"position":1,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCPEL103Pic1.png?v=1610982219"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCPEL103Pic1.png?v=1610982219","width":650},{"alt":null,"id":15453134684350,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCPEL103Pic2.png?v=1610982219"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCPEL103Pic2.png?v=1610982219","width":1200},{"alt":null,"id":15453134717118,"position":3,"preview_image":{"aspect_ratio":1.0,"height":650,"width":650,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCPEL103Pic3.png?v=1610982222"},"aspect_ratio":1.0,"height":650,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMCPEL103Pic3.png?v=1610982222","width":650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe PEL 103 is a low cost, simple to use, one, two (split phase) and three phase power\/energy data logger. This product is ideal for electricians, engineers and contractors doing work in the area of building and system monitoring and upgrades, as well as residential and overall energy audits. All vital energy data is easily measured, recorded, and analyzed. Reports can be generated with confidence with minimal configuration time and effort (Standard and Customizable Reports supplied).\u003c\/p\u003e\n\u003cp\u003eThe instrument’s design enables it to be installed inside a load center panel (including the current sensors) allowing the door to close on most panels. The PEL 100 series offers all the essential functions for logging power\/energy data from most electrical power networks in use today across the world (17 network set-ups provided). The PEL 100 series energy loggers measure and record three True RMS voltage inputs and current inputs, Watts, VARS, VA and Energy (kWh and kVA). Power Factor (PF), Displacement Power Factor (DPF), Crest Factor, Frequency and THD are calculated and recorded as well. Individual harmonic % information from 1 to the 50th harmonic are recorded at the operator’s choice. All variables are recorded and stored at a one second interval and on user selectable demand intervals from 1 to 60 minutes.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasurement of RMS voltages and currents at 128 times per cycle and stored every second\u003c\/li\u003e\n\u003cli\u003eMeasurement of VA, W and var power values (total and per phase) stored every second\u003c\/li\u003e\n\u003cli\u003eMeasurement of VAh, Wh and varh energy values (total and per phase) per second with source\/load indication\u003c\/li\u003e\n\u003cli\u003eCalculation of the cos φ Displacement Power Factor (DPF) and the Power Factor (PF) stored every second\u003c\/li\u003e\n\u003cli\u003eCalculation of Total Harmonic Distortion (THD)\u003c\/li\u003e\n\u003cli\u003eMeasurement, calculation and display of the harmonics up to the 50th order for 50\/60 Hz and 7th order for 400Hz\u003c\/li\u003e\n\u003cli\u003eMeasurement of the DC quantities (RMS calculation)\u003c\/li\u003e\n\u003cli\u003eDisplay Measurements\u003c\/li\u003e\n\u003cli\u003eElectrical network quantities are stored on a removable SD-Card\u003c\/li\u003e\n\u003cli\u003eAutomatic recognition of the connected current sensors\u003c\/li\u003e\n\u003cli\u003eDataView software for configuration, data retrieval and real-time viewing of measurements with a PC\u003c\/li\u003e\n\u003cli\u003eCompact and rugged case\u003c\/li\u003e\n\u003cli\u003eVersatile communication interface choices built in (USB, Ethernet, Bluetooth)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003enputs \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003e3 Voltage \/ 3 Current: calculation of neutral current\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\n\u003cstrong\u003eSample Rate\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e128 per Cycle\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003e6.4kHz at 50Hz\u003c\/td\u003e\n\u003ctd width=\"222\" valign=\"top\" colspan=\"2\"\u003e7.68kHz at 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e\u003cstrong\u003eAccuracy (Typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"610\" valign=\"top\" colspan=\"6\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eVolt\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eVrms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e1000V P to N\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003e10 to 1000V\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e0.1V\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±0.2% Rdg + 0.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eUrms\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e1000V P to P\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003e17 to 1700V\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e0.1V\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±0.2% Rdg + 0.4V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"610\" valign=\"top\" colspan=\"6\"\u003e\u003cstrong\u003eAmps @ 50 and 60Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\n\u003cstrong\u003eAmps (1V nominal)\u003c\/strong\u003e\u003cbr\u003e(excluding clamp accuracy\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003eProbe dependent\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e0.2%\u0026lt; I \u0026lt; 120% Inom\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003eProbe dependent\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±0.2% Rdg + 0.02% Inom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\n\u003cstrong\u003eAmpFLEX \u0026amp; MiniFlex \u003c\/strong\u003e\u003cbr\u003e(including sensor accuracy)\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003eRange 100A \u003cbr\u003eRange 400A\u003cbr\u003eRange 2kA\u003cbr\u003eRange 10kA\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e200mA to 120A\u003cbr\u003e5 to 440A\u003cbr\u003e50 to 2400A\u003cbr\u003e400A to 12kA\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e1mA\u003cbr\u003e0.1A\u003cbr\u003e0.1A \u0026amp; 1A\u003cbr\u003e1A\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±1.2% Rdg + 50mA\u003cbr\u003e±1.2% Rdg + 0.2A\u003cbr\u003e±1.2% Rdg + 1A\u003cbr\u003e±1.2% Rdg + 5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e42.5 to 69Hz\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e0.01Hz\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±0.1Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"610\" valign=\"top\" colspan=\"6\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"262\" valign=\"top\" colspan=\"2\"\u003e\u003cstrong\u003eWatts (VA, var) P-Q-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e10W to 10GW \/ 10var to 10Gvar \/ 10VA to 10GVA\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e4 digits min\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±0.5% Rdg + 0.005% Pnom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"262\" valign=\"top\" colspan=\"2\"\u003e\u003cstrong\u003ePower Factor (Cos Φ\/DPF)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e-1  to 1\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e0.001\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±0.05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"610\" valign=\"top\" colspan=\"6\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eEnergy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003ekWh (kVAh, kvarh) P-Q-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"330\" valign=\"top\" colspan=\"4\"\u003eUp to 4EWh \/ 4Evarh \/ 4 EVAh (E = 1018 )\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±0.5% Rdg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eHarmonics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eDC, 1 to 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eVolts \u0026amp; Amp %\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e0.01 to 655.0%\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e0.01%\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±1% Rdg from 1 to 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eTHD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"120\" valign=\"top\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"126\" valign=\"top\" colspan=\"2\"\u003e0.00 to 655.0%\u003c\/td\u003e\n\u003ctd width=\"84\" valign=\"top\"\u003e0.01%\u003c\/td\u003e\n\u003ctd width=\"138\" valign=\"top\"\u003e±1% Rdg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"610\" valign=\"top\" colspan=\"6\" bgcolor=\"#cccccc\"\u003e\u003cstrong\u003eGeneral Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eCase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eDesign Rugged, shock proof with integrated protective holster, IP54 not included terminals. Shock and vibration IEC61010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eIsolated USB, Bluetooth, and Ethernet, SD card for direct transfer to PC. Dataview software for real time data, configuration and reporting included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003e8GB SD card (SDHC compliant, FAT32 formatted)  32GB max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eLCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eReal-Time Clock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eTime and date stamp for Trend mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eAC 110V\/230V 50\/60Hz 15VA; Battery backup when power OFF, 60 minutes typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003e10.08 x 4.92 x 1.46” (256 x 125 x 37mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003e2.2lbs (1kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eAltitude Operating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003e2000m (6560ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003e32 to 108.5°F; (0°C to +42.5°C) from 10 to 85% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003e-4 to 122°F; (-20°C to +50°C) from 0 to 75% RH with battery pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eElectro-Magnetic-Compatibility (EMC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eEN 61326-1 for emission and immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eIP54 per IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"142\" valign=\"top\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"468\" valign=\"top\" colspan=\"5\"\u003eIEC\/EN 61010-1 (1000V CAT III-600V CAT IV), IEC 1326-1\u003cimg src=\"https:\/\/www.aemc.com\/userfiles\/images\/logos\/ETL_Logo_CE.png\" alt=\"\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePower \u0026amp; Energy Logger Model PEL 102\u003c\/li\u003e\n\u003cli\u003e4 x Black Test Leads and Alligator Clips\u003c\/li\u003e\n\u003cli\u003e12 x Color-coded ID Markers\u003c\/li\u003e\n\u003cli\u003e3 x MA193-10-BK MiniFlex®\u003c\/li\u003e\n\u003cli\u003eSmall Classic Tool Bag\u003c\/li\u003e\n\u003cli\u003eMultifix (mounting system)\u003c\/li\u003e\n\u003cli\u003eUSB SD-Card Adapter\u003c\/li\u003e\n\u003cli\u003ePower Cord, 5 ft 115V\u003c\/li\u003e\n\u003cli\u003e5 ft USB Cable\u003c\/li\u003e\n\u003cli\u003e2 GB SD-Card\u003c\/li\u003e\n\u003cli\u003e4 GB USB Stick with DataView® Software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_PEL_103_-_2137.52_-_Power_and_Energy_Logger_Spec_Sheet.pdf?v=1610981824\" target=\"_blank\" title=\"AEMC PEL 103 Power\/Energy Data Logger Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC PEL 103 Power\/Energy Data Logger Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
AEMC PEL 103 Power/Energy Data Logger Kit with LCD

AEMC PEL 103 Power/Energy Data Logger Kit with LCD

$3,493.00 CAD

The PEL 103 is a low cost, simple to use, one, two (split phase) and three phase power/energy data logger. This product is ideal for electricians, engineers and contractors doing work in the area of building and system monitoring and upgrades, as well as residential and overall energy audits. All vital energy data is easily measured, recorded, a...


More Info
{"id":1262703542315,"title":"Fluke 430-II Series Power Quality and Energy Analyzers","handle":"fluke-434-ii-three-phase-power-quality-analyzer","description":"\u003ch1\u003e*No Longer Available - Replaced by Fluke 1770 Series (1773\/1775\/1777)*\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 434-II Energy Analyzer and 435-II Power Quality and Energy Analyzer are designed to help you minimize downtime, quickly troubleshoot power quality issues and easily discover the costs of wasted energy. Downtime is expensive and getting the data you need to solve to critical power quality problems quickly is key. The 434-II and 435-II Analyzer’s measurement process and data output have been optimized to help you access the most critical information easily.\u003c\/p\u003e\n\u003cp\u003eMultiple parameters are measured simultaneously and displayed in formats that quickly describe overall power quality health. The detailed information helps you make better maintenance decisions—whether you’re trying to reduce energy waste, find the source of power quality issues or see how motor startups are affecting your electrical system. Data can be accessed as simple digital values, trend graphs (for fast insight into changes over time), waveforms, or phasor diagrams. The data can also be analyzed and organized into tabular formats. Detailed event data allows you to see the magnitude, duration and time stamping of anomalies enabling you to rapidly correlate the problems you are experiencing in your facility.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eAnalyze power quality issues, calculate the costs of wasted energy and prevent downtime with the Fluke 434-II Energy Analyzer and Fluke 435-II Power Quality and Energy Analyzer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced power quality health—\u003c\/strong\u003eAt-a-glance power quality health data in real time so you can make better maintenance decisions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy loss calculator—\u003c\/strong\u003eDiscover the costs of energy loss specifically caused by poor power quality\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighest safety rating in industry—\u003c\/strong\u003eCAT III 1000 V \/ CAT IV 600 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\" itemprop=\"name\"\u003e\u003cstrong\u003eFluke 434 Series II Three-Phase Energy Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBC430 Power Adapter\u003c\/li\u003e\n\u003cli\u003eInternational plug adapter set\u003c\/li\u003e\n\u003cli\u003eBP290 (Single capacity Li-ion battery) 28 Wh (8 hours or more)\u003c\/li\u003e\n\u003cli\u003eTLS430 Test lead and Alligator clip set\u003c\/li\u003e\n\u003cli\u003eWC100 color coding clips and regional decals\u003c\/li\u003e\n\u003cli\u003ei430flex-TF, 24 inch (61 cm) length, 4 flexible current probes\u003c\/li\u003e\n\u003cli\u003e16GB Wi-Fi SD card (8GB SD card for \/INTL models)\u003c\/li\u003e\n\u003cli\u003ePowerLog on CD (includes operator manuals in PDF format)\u003c\/li\u003e\n\u003cli\u003eUSB cable A - Mini B\u003c\/li\u003e\n\u003cli\u003eC1740 Soft Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cstrong\u003eFluke 434 Series II Basic Energy Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBC430 Power Adapter\u003c\/li\u003e\n\u003cli\u003eInternational Plug Adapter Set\u003c\/li\u003e\n\u003cli\u003eBP290 (Single Capacity Li-ion Battery) 28 Wh (8 hours or more)\u003c\/li\u003e\n\u003cli\u003eTLS430 Test Lead and Alligator Clip Set\u003c\/li\u003e\n\u003cli\u003eWC100 Color Coding Clips and Regional Decals\u003c\/li\u003e\n\u003cli\u003e16GB Wi-Fi SD card (8GB SD card for \/INTL models)\u003c\/li\u003e\n\u003cli\u003ePowerLog on CD (includes operator manuals in PDF format)\u003c\/li\u003e\n\u003cli\u003eUSB Cable A - Mini B\u003c\/li\u003e\n\u003cli\u003eC1740 Soft Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cstrong\u003eFluke 435 Series II Power Quality and Energy Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBC430 Power Adapter\u003c\/li\u003e\n\u003cli\u003eInternational Plug Adapter Set\u003c\/li\u003e\n\u003cli\u003eBP290 (Single Capacity Li-ion Battery) 28 Wh (8 hours or more)\u003c\/li\u003e\n\u003cli\u003eTLS430 Test Lead and Alligator Clip Set\u003c\/li\u003e\n\u003cli\u003eWC100 Color Coding Clips and Regional Decals\u003c\/li\u003e\n\u003cli\u003ei430-Flexi-TF-II, 24 inch (61 cm) Length, 4 Flexible Current Probes\u003c\/li\u003e\n\u003cli\u003e16GB Wi-Fi SD card (8GB SD card for \/INTL models)\u003c\/li\u003e\n\u003cli\u003ePowerLog on CD (includes operator manuals in PDF format)\u003c\/li\u003e\n\u003cli\u003eUSB Cable A - Mini B\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Bag\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cstrong\u003eFluke 435 Series II Basic Power Quality and Energy Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBC430 Power Adapter\u003c\/li\u003e\n\u003cli\u003eInternational Plug Adapter Set\u003c\/li\u003e\n\u003cli\u003eBP290 (Single Capacity Li-ion Battery) 28 Wh (8 hours or more)\u003c\/li\u003e\n\u003cli\u003eTLS430 Test Lead and Alligator Clip Set\u003c\/li\u003e\n\u003cli\u003eWC100 Color Coding Clips and Regional Decals\u003c\/li\u003e\n\u003cli\u003e16GB Wi-Fi SD card (8GB SD card for \/INTL models)\u003c\/li\u003e\n\u003cli\u003ePowerLog on CD (includes operator manuals in PDF format)\u003c\/li\u003e\n\u003cli\u003eUSB Cable A - Mini B\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_430_Series_Spec.pdf?1831\" title=\"Fluke 430 Series II Spec Sheet\" target=\"_blank\"\u003eFluke 430 Series II Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-05-16T12:18:07-06:00","created_at":"2018-05-16T12:24:00-06:00","vendor":"Fluke","type":"Power Quality","tags":[],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12140268912683,"title":"FLU-434-II\/BASIC","option1":"FLU-434-II\/BASIC","option2":null,"option3":null,"sku":"FLU-434-II\/BASIC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 430-II Series Power Quality and Energy Analyzers - FLU-434-II\/BASIC","public_title":"FLU-434-II\/BASIC","options":["FLU-434-II\/BASIC"],"price":0,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969615556","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":30272679215147,"title":"FLU-434-II","option1":"FLU-434-II","option2":null,"option3":null,"sku":"FLU-434-II","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 430-II Series Power Quality and Energy Analyzers - FLU-434-II","public_title":"FLU-434-II","options":["FLU-434-II"],"price":0,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969615532","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":30272679247915,"title":"FLU-435-II\/BASIC","option1":"FLU-435-II\/BASIC","option2":null,"option3":null,"sku":"FLU-435-II\/BASIC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 430-II Series Power Quality and Energy Analyzers - FLU-435-II\/BASIC","public_title":"FLU-435-II\/BASIC","options":["FLU-435-II\/BASIC"],"price":0,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969615587","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":30272679280683,"title":"FLU-435-II","option1":"FLU-435-II","option2":null,"option3":null,"sku":"FLU-435-II","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 430-II Series Power Quality and Energy Analyzers - FLU-435-II","public_title":"FLU-435-II","options":["FLU-435-II"],"price":0,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969615563","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke__434-II-Basic-900x900.jpg?v=1526495042","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_430_Series.jpg?v=1569940508"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke__434-II-Basic-900x900.jpg?v=1526495042","options":["Model"],"media":[{"alt":null,"id":1663340806187,"position":1,"preview_image":{"aspect_ratio":1.0,"height":900,"width":900,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke__434-II-Basic-900x900.jpg?v=1526495042"},"aspect_ratio":1.0,"height":900,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke__434-II-Basic-900x900.jpg?v=1526495042","width":900},{"alt":null,"id":2356976451627,"position":2,"preview_image":{"aspect_ratio":1.333,"height":960,"width":1280,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_430_Series.jpg?v=1569940508"},"aspect_ratio":1.333,"height":960,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_430_Series.jpg?v=1569940508","width":1280}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch1\u003e*No Longer Available - Replaced by Fluke 1770 Series (1773\/1775\/1777)*\u003c\/h1\u003e\n\u003cp\u003eThe Fluke 434-II Energy Analyzer and 435-II Power Quality and Energy Analyzer are designed to help you minimize downtime, quickly troubleshoot power quality issues and easily discover the costs of wasted energy. Downtime is expensive and getting the data you need to solve to critical power quality problems quickly is key. The 434-II and 435-II Analyzer’s measurement process and data output have been optimized to help you access the most critical information easily.\u003c\/p\u003e\n\u003cp\u003eMultiple parameters are measured simultaneously and displayed in formats that quickly describe overall power quality health. The detailed information helps you make better maintenance decisions—whether you’re trying to reduce energy waste, find the source of power quality issues or see how motor startups are affecting your electrical system. Data can be accessed as simple digital values, trend graphs (for fast insight into changes over time), waveforms, or phasor diagrams. The data can also be analyzed and organized into tabular formats. Detailed event data allows you to see the magnitude, duration and time stamping of anomalies enabling you to rapidly correlate the problems you are experiencing in your facility.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eAnalyze power quality issues, calculate the costs of wasted energy and prevent downtime with the Fluke 434-II Energy Analyzer and Fluke 435-II Power Quality and Energy Analyzer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced power quality health—\u003c\/strong\u003eAt-a-glance power quality health data in real time so you can make better maintenance decisions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy loss calculator—\u003c\/strong\u003eDiscover the costs of energy loss specifically caused by poor power quality\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHighest safety rating in industry—\u003c\/strong\u003eCAT III 1000 V \/ CAT IV 600 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-name\" itemprop=\"name\"\u003e\u003cstrong\u003eFluke 434 Series II Three-Phase Energy Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBC430 Power Adapter\u003c\/li\u003e\n\u003cli\u003eInternational plug adapter set\u003c\/li\u003e\n\u003cli\u003eBP290 (Single capacity Li-ion battery) 28 Wh (8 hours or more)\u003c\/li\u003e\n\u003cli\u003eTLS430 Test lead and Alligator clip set\u003c\/li\u003e\n\u003cli\u003eWC100 color coding clips and regional decals\u003c\/li\u003e\n\u003cli\u003ei430flex-TF, 24 inch (61 cm) length, 4 flexible current probes\u003c\/li\u003e\n\u003cli\u003e16GB Wi-Fi SD card (8GB SD card for \/INTL models)\u003c\/li\u003e\n\u003cli\u003ePowerLog on CD (includes operator manuals in PDF format)\u003c\/li\u003e\n\u003cli\u003eUSB cable A - Mini B\u003c\/li\u003e\n\u003cli\u003eC1740 Soft Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cstrong\u003eFluke 434 Series II Basic Energy Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBC430 Power Adapter\u003c\/li\u003e\n\u003cli\u003eInternational Plug Adapter Set\u003c\/li\u003e\n\u003cli\u003eBP290 (Single Capacity Li-ion Battery) 28 Wh (8 hours or more)\u003c\/li\u003e\n\u003cli\u003eTLS430 Test Lead and Alligator Clip Set\u003c\/li\u003e\n\u003cli\u003eWC100 Color Coding Clips and Regional Decals\u003c\/li\u003e\n\u003cli\u003e16GB Wi-Fi SD card (8GB SD card for \/INTL models)\u003c\/li\u003e\n\u003cli\u003ePowerLog on CD (includes operator manuals in PDF format)\u003c\/li\u003e\n\u003cli\u003eUSB Cable A - Mini B\u003c\/li\u003e\n\u003cli\u003eC1740 Soft Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cstrong\u003eFluke 435 Series II Power Quality and Energy Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBC430 Power Adapter\u003c\/li\u003e\n\u003cli\u003eInternational Plug Adapter Set\u003c\/li\u003e\n\u003cli\u003eBP290 (Single Capacity Li-ion Battery) 28 Wh (8 hours or more)\u003c\/li\u003e\n\u003cli\u003eTLS430 Test Lead and Alligator Clip Set\u003c\/li\u003e\n\u003cli\u003eWC100 Color Coding Clips and Regional Decals\u003c\/li\u003e\n\u003cli\u003ei430-Flexi-TF-II, 24 inch (61 cm) Length, 4 Flexible Current Probes\u003c\/li\u003e\n\u003cli\u003e16GB Wi-Fi SD card (8GB SD card for \/INTL models)\u003c\/li\u003e\n\u003cli\u003ePowerLog on CD (includes operator manuals in PDF format)\u003c\/li\u003e\n\u003cli\u003eUSB Cable A - Mini B\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Bag\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003e\u003cstrong\u003eFluke 435 Series II Basic Power Quality and Energy Analyzer\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBC430 Power Adapter\u003c\/li\u003e\n\u003cli\u003eInternational Plug Adapter Set\u003c\/li\u003e\n\u003cli\u003eBP290 (Single Capacity Li-ion Battery) 28 Wh (8 hours or more)\u003c\/li\u003e\n\u003cli\u003eTLS430 Test Lead and Alligator Clip Set\u003c\/li\u003e\n\u003cli\u003eWC100 Color Coding Clips and Regional Decals\u003c\/li\u003e\n\u003cli\u003e16GB Wi-Fi SD card (8GB SD card for \/INTL models)\u003c\/li\u003e\n\u003cli\u003ePowerLog on CD (includes operator manuals in PDF format)\u003c\/li\u003e\n\u003cli\u003eUSB Cable A - Mini B\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_430_Series_Spec.pdf?1831\" title=\"Fluke 430 Series II Spec Sheet\" target=\"_blank\"\u003eFluke 430 Series II Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 430-II Series Power Quality and Energy Analyzers

Fluke 430-II Series Power Quality and Energy Analyzers

Call for pricing

*No Longer Available - Replaced by Fluke 1770 Series (1773/1775/1777)* The Fluke 434-II Energy Analyzer and 435-II Power Quality and Energy Analyzer are designed to help you minimize downtime, quickly troubleshoot power quality issues and easily discover the costs of wasted energy. Downtime is expensive and getting the data you need to solve to ...


More Info
{"id":1292636880939,"title":"Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature","handle":"amprobe-acd-41pq-1000a-power-quality-clamp-meter-with-temperature","description":"The Amprobe ACD-40 provides a simple and effective way to verify if the electrical system is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ data-logging feature or get complete power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit.\u003cbr\u003e\u003cbr\u003eTHD-F is defined as: (Total Harmonic RMS \/ Fundamental RMS) x 100%","published_at":"2018-05-30T16:10:29-06:00","created_at":"2018-05-30T16:13:45-06:00","vendor":"Amprobe","type":"Power Quality","tags":[],"price":79998,"price_min":79998,"price_max":79998,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12339390971947,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"Amprobe ACD-41PQ","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature","public_title":null,"options":["Default Title"],"price":79998,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969365864","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/acd-41pq.jpg?v=1527718428","\/\/kingswayinstruments.com\/cdn\/shop\/products\/81vXfcK8G1L._SL1500.jpg?v=1527718429"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/acd-41pq.jpg?v=1527718428","options":["Title"],"media":[{"alt":null,"id":1690977206315,"position":1,"preview_image":{"aspect_ratio":0.415,"height":1800,"width":747,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/acd-41pq.jpg?v=1527718428"},"aspect_ratio":0.415,"height":1800,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/acd-41pq.jpg?v=1527718428","width":747},{"alt":null,"id":1690977239083,"position":2,"preview_image":{"aspect_ratio":1.385,"height":1083,"width":1500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/81vXfcK8G1L._SL1500.jpg?v=1527718429"},"aspect_ratio":1.385,"height":1083,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/81vXfcK8G1L._SL1500.jpg?v=1527718429","width":1500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"The Amprobe ACD-40 provides a simple and effective way to verify if the electrical system is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ data-logging feature or get complete power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit.\u003cbr\u003e\u003cbr\u003eTHD-F is defined as: (Total Harmonic RMS \/ Fundamental RMS) x 100%"}
Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature

Amprobe ACD-41PQ 1000A Power Quality Clamp Meter with Temperature

$799.98 CAD

The Amprobe ACD-40 provides a simple and effective way to verify if the electrical system is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ data-logging feature or get complete power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit.THD-F is defined as: (Total Harmonic RMS /...


More Info