Fluke 123B Industrial ScopeMeter® Hand-Held Oscilloscope, 2 Channel, 20MHz
Product Description
The compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.
Overview
Features
- Dual-input digital oscilloscope and multimeter
- 20 MHz oscilloscope bandwidth
- Two 5,000-count true-rms digital multimeters
- Connect-and-View™ trigger simplicity for hands-off operation; IntellaSet™ technology automatically and intelligently adjusts numerical readout
- Dual-input waveform and meter reading recorder for trending data over extended periods
- Recorder Event Detect captures elusive intermittent signals
- WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app*
- FlukeView® ScopeMeter® Software for Windows® (FLU-123B/NA/S)
Specifications
Trigger | ||
Screen update | Free run, on trigger | |
Source | A, B | |
Sensitivity A and B | @ DC to 5 MHz | 0.5 divisions or 5 mV |
@ 40 MHz | 123B: 4 divisions | |
124B and 125B: 1.5 divisions | ||
@ 60 MHz | 123B: N/A | |
124B and 125B: 4 divisions | ||
Slope | Positive, negative |
Advanced scope functions | ||
Display modes | Normal | Captures up to 25 ns glitches and displays analog-like persistence waveform |
Smooth | Suppresses noise from a waveform | |
Glitch off | Does not capture glitches between samples | |
Envelope | Records and displays the minimum and maximum of waveforms over time | |
Auto set (Connect-and-View™) | Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level. |
Input A and input B | ||
DC voltage (VDC) | ||
Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V | |
Accuracy | ±(0.5% +5 counts) | |
Common mode rejection (CMRR) | >100 dB @ dc, >60 dB @ 50, 60, or 400 Hz | |
Full scale reading | 5000 counts | |
True-rms voltages (V ac and V ac+dc) | ||
Ranges | 500 mV, 5 V, 50 V, 500 V, 750 V | |
Accuracy for 5% to 100% of range (DC coupled) | DC to 60 Hz (V ac+dc) | ±(1% +10 counts) |
1 Hz to 60 Hz (V ac) | ±(1% +10 counts) | |
Accuracy for 5% to 100% of range (AC or dc coupled) | 60 Hz to 20 kHz | ±(2.5% +15 counts) |
DC rejection (only VAC) | >50 dB | |
Common mode rejection (CMRR) | >100 dB @ dc | |
>60 dB @ 50, 60, or 400 Hz | ||
Full scale reading | 5000 counts, reading is independent of any signal crest factor. | |
Peak | ||
Modes | Max peak, Min peak, or pk-to-pk | |
Ranges | 500 mV, 5 V, 50 V, 500 V, 2200 V | |
Accuracy | Accuracy Max peak or Min peak | 5% of full scale |
Accuracy Peak-to-Peak | 10% of full scale | |
Full scale reading | 500 counts | |
Recorder | ||
The recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B). | ||
The results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples. | ||
Meter readings | ||
Measurement Speed | Maximum 2 measurement/s | |
Record Size (min, max, average) | 2 M readings for 1 channel | |
Recorded Time Span | 2 weeks | |
Maximum number of events | 1024 | |
Waveform record | ||
Maximum sample rate | 400 K sample/s | |
Size Internal memory | 400 M samples Recorded Time | |
Span internal memory | 15 minutes at 500 μs/div 11 hours at 20 ms/div |
|
Record Size SD card | 1.5 G samples | |
Recorded Time Span SD card | 11 hours at 500 μs/div 14 days at 20 ms/div |
|
Maximum number of events | 64 |
Power Quality (125B only) | ||
Readings | Watt, VA, var, PF, DPF, Hz | |
Watt, VA, var ranges (auto) | 250 W to 250 MW, 625 MW, 1.56 GW | |
When selected: total (% r) | ±(2% + 6 counts) | |
When selected: fundamental (% f) | ±(4% + 4 counts) | |
DPF | 0.00 to 1.00 | |
PF | 0.00 to 1.00, ±0.04 | |
Frequency range | 10.0 Hz to 15.0 kHz 40.0 Hz to 70.0 Hz |
|
Number of Harmonics | DC to 51 | |
Readings / Cursor readings (fundamental 40 Hz to 70 Hz) |
Vrms / Arms /Watt | Each harmonic from fundamental maybe selected for individual readings |
Includes frequency of fundamental, phase Angle and K-factor (in Amp and Watt) |
What's in the Box
- Oscilloscope
- Accessory List
- CD
- Safety Manual
- Banana to BNC Adapter
- Power Adapter
- Shield Test Leads with Black ground Leads
- TL175 Test Leads
- Battery
- WiFi Dongle
- Line Cord