{ "id":1069130022955, "title":"Fluke 1555 10kV Digital Insulation Tester","handle":"fluke-1555-10kv-insulation-resistance-tester", "description":"\u003cp\u003e\u003cspan\u003eEvaluate the trends and eliminate the doubt with this insulation resistance tester. Ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables, the CAT III 1000 V\/CAT IV 600 V safety-rated tester can conduct digital insulation testing up to 10 kV. By adding this to your preventive or predictive maintenance programs, it can help to identify potential equipment failures before they occur.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest voltages to up 10 kV and save time by trending on the spot only with Fluke Connect™\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage (DC)\u003c\/td\u003e\n\u003ctd\u003eRange (DC)\u003c\/td\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e250 kΩ to 5 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 GΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 50 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e500 kΩ to 10 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 GΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 100 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e1 MΩ to 20 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20 GΩ to 200 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 200 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e50 GΩ to 500 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 500 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 MΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e100 GΩ to 1 TΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 1 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 MΩ to 200 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 GΩ to 2 TΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 2 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLeakage Current Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 nA to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (5 % + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCapacitance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 uF to 15.00°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (15 % rdg + 0.03°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eTimer\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 99 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eResolution Setting: 1 minute Indication: 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModel 1555\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eTest Cables with Alligator Clips\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC Power Cord\u003c\/li\u003e\n\u003cli\u003eUsers Manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Installation Guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR Cable Installation Guide\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel 1555\/KIT\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eTest cables with alligator clips (red, black, green)\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC power cord\u003c\/li\u003e\n\u003cli\u003eUser's manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms installation guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR cable installation guide\u003c\/li\u003e\n\u003cli\u003eHeavy duty alligator clip leads\u003c\/li\u003e\n\u003cli\u003eHard Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel 1555FC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eIR3000FC1550 Connector\u003c\/li\u003e\n\u003cli\u003eTest Cables with Alligator Clips\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC Power Cord\u003c\/li\u003e\n\u003cli\u003eUsers Manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Installation Guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR Cable Installation Guide\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1550-1555_Spec.pdf?1595\" target=\"_blank\" title=\"Fluke 1555 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1555 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-03-05T15:57:38", "created_at":"2018-03-05T16:00:01", "vendor":"Fluke", "type":"Insulation Testers", "tags":[], "price":961655, "price_min":961655, "price_max":1065151, "price_varies":true, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[11001299370027,16793619922987,16793619955755], "variants":[{ "id":11001299370027, "product_id":1069130022955, "product_handle":"fluke-1555-10kv-insulation-resistance-tester", "title":"1555", "option1":"1555", "option2":null, "option3":null, "sku":"FLU-1555", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 1555 10kV Digital Insulation Tester - 1555", "options":["1555"], "price":961655, "weight":6804, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969550925"},{ "id":16793619922987, "product_id":1069130022955, "product_handle":"fluke-1555-10kv-insulation-resistance-tester", "title":"1555\/KIT", "option1":"1555\/KIT", "option2":null, "option3":null, "sku":"FLU-1555\/KIT", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 1555 10kV Digital Insulation Tester - 1555\/KIT", "options":["1555\/KIT"], "price":1065151, "weight":6804, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969550970"},{ "id":16793619955755, "product_id":1069130022955, "product_handle":"fluke-1555-10kv-insulation-resistance-tester", "title":"1555 FC", "option1":"1555 FC", "option2":null, "option3":null, "sku":"FLU-1555FC", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 1555 10kV Digital Insulation Tester - 1555 FC", "options":["1555 FC"], "price":961655, "weight":6804, "compare_at_price":null, "inventory_quantity":1, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":1, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969868891"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1555-f5d-1.jpg?v=1520290804"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1555-f5d-1.jpg?v=1520290804", "options":["Model"], "url":"\/products\/fluke-1555-10kv-insulation-resistance-tester"}

Fluke 1555 10kV Digital Insulation Tester

Product Description

Evaluate the trends and eliminate the doubt with this insulation resistance tester. Ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables, the CAT III 1000 V/CAT IV 600 V safety-rated tester can conduct digital insulation testing up to 10 kV. By adding this to your preventive or predictive maintenance programs, it can help to identify potential equipment failures before they occur.

Sku: FLU-1555
Vendor: Fluke
On Back-Order
$9,616.55 CAD

  • Test voltages to up 10 kV and save time by trending on the spot only with Fluke Connect™
  • CAT III 1000 V, CAT IV 600 V safety rating
  • Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
  • Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V
  • Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
  • Long battery life gives the user over 750 tests between charges
  • Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
  • Guard system eliminates the effect of surface leakage current on high-resistance measurements
  • Large digital/analog LCD for easy viewing
  • Capacitance and leakage current measurement
  • Ramp function for breakdown testing
  • Resistance measurements up to 2 TΩ
  • Timer settings up to 99 minutes for timed tests
  • 3-year warranty
Insulation Resistance
Test voltage (DC) Range (DC) Accuracy (± reading)
250 V < 250 kΩ 
250 kΩ to 5 GΩ 
5 GΩ to 50 GΩ 
> 50 GΩ
Unspecified 
5% 
20% 
Unspecified
500 V < 500 kΩ 
500 kΩ to 10 GΩ 
10 GΩ to 100 GΩ 
> 100 GΩ
Unspecified 
5% 
20% 
Unspecified
1000 V < 1 MΩ 
1 MΩ to 20 GΩ 
20 GΩ to 200 GΩ 
> 200 GΩ
Unspecified 
5% 
20% 
Unspecified
2500 V < 2.5 MΩ 
2.5 MΩ to 50 GΩ 
50 GΩ to 500 GΩ 
> 500 GΩ
Unspecified 
5% 
20% 
Unspecified
5000 V < 5 MΩ 
5 MΩ to 100 GΩ 
100 GΩ to 1 TΩ 
> 1 TΩ
Unspecified 
5% 
20%
Unspecified
10000 V < 10 MΩ 
10 MΩ to 200 GΩ 
10 GΩ to 2 TΩ 
> 2 TΩ
Unspecified 
5% 
20% 
Unspecified
Leakage Current Measurement
Range 1 nA to 2 mA
Accuracy ± (5 % + 2 nA)
Capacitance Measurement
Range 0.01 uF to 15.00°F
Accuracy ± (15 % rdg + 0.03°F)
Timer
Range 0 to 99 minutes
Accuracy Resolution Setting: 1 minute Indication: 1 second


Model 1555

  • Insulation Resistance Tester
  • Test Cables with Alligator Clips
  • Infrared adapter with interface cable
  • FlukeView® Forms Basic CD-ROM
  • AC Power Cord
  • Users Manual on CD-ROM
  • FlukeView® Forms Installation Guide
  • USB-IR Cable Installation Guide
  • Soft Carrying Case

Model 1555/KIT

  • Insulation Resistance Tester
  • Test cables with alligator clips (red, black, green)
  • Infrared adapter with interface cable
  • FlukeView® Forms Basic CD-ROM
  • AC power cord
  • User's manual on CD-ROM
  • FlukeView® Forms installation guide
  • USB-IR cable installation guide
  • Heavy duty alligator clip leads
  • Hard Carrying Case

Model 1555FC

  • Insulation Resistance Tester
  • IR3000FC1550 Connector
  • Test Cables with Alligator Clips
  • Infrared adapter with interface cable
  • FlukeView® Forms Basic CD-ROM
  • AC Power Cord
  • Users Manual on CD-ROM
  • FlukeView® Forms Installation Guide
  • USB-IR Cable Installation Guide
  • Soft Carrying Case

Related Products