{ "id":1262797520939, "title":"Megger MIT1025 10kV Insulation Tester","handle":"megger-mit1025-10kv-insulation-tester", "description":"\u003cp\u003eThe MIT1025 is compact, light 10 kV insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store.\u003c\/p\u003e\n\u003cp\u003eAs well as measuring insulation resistance to 20 TΩ, the MIT1025 also offers various diagnostic tests such as Polarization index, Dielectric Absorption Ratio, Step Voltage, Dielectric discharge and ramp testing.\u003c\/p\u003e\n\u003cp\u003eNow equipped with lithium ion fast rechargeable batteries, the instrument has a large, clear, easy to read, display making it equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly removing the need for separate timer.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustry best guard terminal accuracy\u003c\/li\u003e\n\u003cli\u003eSmaller size and lightweight allows easier transport and use without compromising performance\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight for easy transport and use\u003c\/li\u003e\n\u003cli\u003eAuto IR, DAR, PI, Step Voltage, DD and Ramp\u003c\/li\u003e\n\u003cli\u003eUnique dual case design provides additional user protection\u003c\/li\u003e\n\u003cli\u003eLithium-ion battery - extended capacity rapid charge\u003c\/li\u003e\n\u003cli\u003eAdvanced memory with time\/date stamp\u003c\/li\u003e\n\u003cli\u003eCATIV 600V safety rating on all terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical contractors\u003c\/li\u003e\n\u003cli\u003eTesting and service companies\u003c\/li\u003e\n\u003cli\u003eWind farm and solar generation operators\u003c\/li\u003e\n\u003cli\u003ePower generation and distribution companies\u003c\/li\u003e\n\u003cli\u003eIndustrial companies\u003c\/li\u003e\n\u003cli\u003eRail companies\u003c\/li\u003e\n\u003cli\u003eAcceptance testing at installation to check conformance to specifications\u003c\/li\u003e\n\u003cli\u003eRoutine preventive\/predictive maintenance testing after installation\u003c\/li\u003e\n\u003cli\u003eQA testing as part of the manufacturing process\u003c\/li\u003e\n\u003cli\u003eDiagnostic testing to isolate faulty components for repair\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Range, Analog\u003c\/td\u003e\n\u003ctd\u003e100kW to 10TW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Range, Digital\u003c\/td\u003e\n\u003ctd\u003e10kW to 20TW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e500V, 1000V, 2500V, 5000V, and 10,000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Defined Test Voltages\u003c\/td\u003e\n\u003ctd\u003e100V to 1kV in 10V steps\u003cbr\u003e1kV to 5kV in 25V steps\u003cbr\u003e5kV to 10kV in 25V steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±5% to 2TΩ, ±20% to 20TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Accuracy\u003c\/td\u003e\n\u003ctd\u003e+4% -0% ±10V of nominal test voltage at 1GW load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Range\u003c\/td\u003e\n\u003ctd\u003e30 to 660V AC\/DC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3% ±3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e45 to 65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current\u003c\/td\u003e\n\u003ctd\u003e3mA nominal, max. power on all loads outperforming many 5mA testers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Alarm\u003c\/td\u003e\n\u003ctd\u003e100kΩ to 1GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e0.01nA to 6mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% ±0.2 nA at all voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range (above 500V)\u003c\/td\u003e\n\u003ctd\u003e10nF to 25µF (dependent on measurement voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10% ±5nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Charge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5s per µF at 3mA to 10kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Discharge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;500 ms\/µF to discharge from 10,000V to 50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMIT1025 Megohmmeter\u003c\/li\u003e\n\u003cli\u003ePower lead\u003c\/li\u003e\n\u003cli\u003e3 x 1002-531 Medium insulated clips, 10ft (3m) leadset\u003c\/li\u003e\n\u003cli\u003e3 x 1002-534 Large insulated clips, 10ft (3m) leadset\u003c\/li\u003e\n\u003cli\u003eUser guide CD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/MIT515_525_1025_specs.pdf?1591\" target=\"_blank\" title=\"Megger MIT1025 Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger MIT1025 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-05-16T12:41:14", "created_at":"2018-05-16T12:41:17", "vendor":"Megger", "type":"Insulation Testers", "tags":[], "price":978500, "price_min":978500, "price_max":978500, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[12140446318635], "variants":[{ "id":12140446318635, "product_id":1262797520939, "product_handle":"megger-mit1025-10kv-insulation-tester", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"MEG-MIT1025-US", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Megger MIT1025 10kV Insulation Tester - Default Title", "options":["Default Title"], "price":978500, "weight":3175, "compare_at_price":null, "inventory_quantity":1, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":1, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":""}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit1025-f26.jpg?v=1526496155"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit1025-f26.jpg?v=1526496155", "options":["Title"], "url":"\/products\/megger-mit1025-10kv-insulation-tester"}

Megger MIT1025 10kV Insulation Tester

Product Description

The MIT1025 is compact, light 10 kV insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store.

As well as measuring insulation resistance to 20 TΩ, the MIT1025 also offers various diagnostic tests such as Polarization index, Dielectric Absorption Ratio, Step Voltage, Dielectric discharge and ramp testing.

Now equipped with lithium ion fast rechargeable batteries, the instrument has a large, clear, easy to read, display making it equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly removing the need for separate timer.

Sku: MEG-MIT1025-US
Vendor: Megger
1 left in stock.
$9,785.00 CAD
Maximum quantity available reached.

Features

  • Industry best guard terminal accuracy
  • Smaller size and lightweight allows easier transport and use without compromising performance
  • Compact and lightweight for easy transport and use
  • Auto IR, DAR, PI, Step Voltage, DD and Ramp
  • Unique dual case design provides additional user protection
  • Lithium-ion battery - extended capacity rapid charge
  • Advanced memory with time/date stamp
  • CATIV 600V safety rating on all terminals

Applications

  • Electrical contractors
  • Testing and service companies
  • Wind farm and solar generation operators
  • Power generation and distribution companies
  • Industrial companies
  • Rail companies
  • Acceptance testing at installation to check conformance to specifications
  • Routine preventive/predictive maintenance testing after installation
  • QA testing as part of the manufacturing process
  • Diagnostic testing to isolate faulty components for repair
Insulation Range, Analog 100kW to 10TW
Insulation Range, Digital 10kW to 20TW
Test Voltages 500V, 1000V, 2500V, 5000V, and 10,000V
User Defined Test Voltages 100V to 1kV in 10V steps
1kV to 5kV in 25V steps
5kV to 10kV in 25V steps
Accuracy ±5% to 2TΩ, ±20% to 20TΩ
Voltage Output Accuracy +4% -0% ±10V of nominal test voltage at 1GW load
Voltmeter Range 30 to 660V AC/DC, 50/60Hz
Voltmeter Accuracy ±3% ±3V
Frequency Range 45 to 65Hz
Short Circuit Current 3mA nominal, max. power on all loads outperforming many 5mA testers
Insulation Alarm 100kΩ to 1GΩ
Current Range 0.01nA to 6mA
Current Accuracy ±5% ±0.2 nA at all voltages
Capacitance Range (above 500V) 10nF to 25µF (dependent on measurement voltage)
Capacitance Accuracy ±10% ±5nF
Capacitor Charge <5s per µF at 3mA to 10kV
Capacitor Discharge <500 ms/µF to discharge from 10,000V to 50V


  • MIT1025 Megohmmeter
  • Power lead
  • 3 x 1002-531 Medium insulated clips, 10ft (3m) leadset
  • 3 x 1002-534 Large insulated clips, 10ft (3m) leadset
  • User guide CD

Related Products