Megger

Megger 1002-534 Large Test Clips

Accessories Electrical

$360.00 CAD
{"id":1843630866475,"title":"Megger 1002-534 Large Test Clips","handle":"megger-1002-534-large-test-clips-10-kv-insulated-10-ft","description":"\u003cp\u003e\u003cspan\u003eThree piece insulated 10 kV large test clip set. Each lead is 3 meters in length\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e3 Meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e10 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColors\u003c\/td\u003e\n\u003ctd\u003eRed, Blue, Black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003e\u003c\/h2\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e","published_at":"2019-07-30T10:26:16-06:00","created_at":"2019-07-30T10:29:02-06:00","vendor":"Megger","type":"Accessories Electrical","tags":[],"price":36000,"price_min":36000,"price_max":36000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16825841090603,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-1002-534","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger 1002-534 Large Test Clips","public_title":null,"options":["Default Title"],"price":36000,"weight":907,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/1002-534.jpg?v=1564504144"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/1002-534.jpg?v=1564504144","options":["Title"],"media":[{"alt":null,"id":2811602894891,"position":1,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/1002-534.jpg?v=1564504144"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/1002-534.jpg?v=1564504144","width":500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThree piece insulated 10 kV large test clip set. Each lead is 3 meters in length\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLength\u003c\/td\u003e\n\u003ctd\u003e3 Meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e10 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColors\u003c\/td\u003e\n\u003ctd\u003eRed, Blue, Black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003e\u003c\/h2\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e"}
Megger 1002-534 Large Test Clips

Megger 1002-534 Large Test Clips

$360.00 CAD

Three piece insulated 10 kV large test clip set. Each lead is 3 meters in length Overview Length 3 Meters Voltage 10 kV Quantity 3 Colors Red, Blue, Black Resources


More Info
Megger 1008-022 3-Piece Insulated Lead Clip Set

Accessories Electrical

$320.00 CAD
{"id":1843233194027,"title":"Megger 1008-022 3-Piece Insulated Lead Clip Set","handle":"megger-1008-022-3-piece-insulated-lead-clip-set-5kv-test-voltage","description":"\u003cp\u003e\u003cspan\u003eMegger 1008-022 three-piece insulated lead set with test clips includes one red, one blue, and one black test lead for use with Megger 5KV and 10KV insulation resistance testers. Each 10 foot test lead has a test clip for hands-free connection to a conductor. Silicone insulation on the lead wires and test clips helps protect hands from shock and heat, resists melting or becoming brittle in hot or cold environments, and maintains flexibility better than PVC insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e3m (10 ft) test leads (3) with 3kV insulated clips (3)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e","published_at":"2019-07-29T13:21:25-06:00","created_at":"2019-07-29T13:27:51-06:00","vendor":"Megger","type":"Accessories Electrical","tags":[],"price":32000,"price_min":32000,"price_max":32000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16822501146667,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-1008-022","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger 1008-022 3-Piece Insulated Lead Clip Set","public_title":null,"options":["Default Title"],"price":32000,"weight":454,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/1008-022.jpg?v=1564428474"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/1008-022.jpg?v=1564428474","options":["Title"],"media":[{"alt":null,"id":2811091877931,"position":1,"preview_image":{"aspect_ratio":0.909,"height":450,"width":409,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/1008-022.jpg?v=1564428474"},"aspect_ratio":0.909,"height":450,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/1008-022.jpg?v=1564428474","width":409}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eMegger 1008-022 three-piece insulated lead set with test clips includes one red, one blue, and one black test lead for use with Megger 5KV and 10KV insulation resistance testers. Each 10 foot test lead has a test clip for hands-free connection to a conductor. Silicone insulation on the lead wires and test clips helps protect hands from shock and heat, resists melting or becoming brittle in hot or cold environments, and maintains flexibility better than PVC insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e3m (10 ft) test leads (3) with 3kV insulated clips (3)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e"}
Megger 1008-022 3-Piece Insulated Lead Clip Set

Megger 1008-022 3-Piece Insulated Lead Clip Set

$320.00 CAD

Megger 1008-022 three-piece insulated lead set with test clips includes one red, one blue, and one black test lead for use with Megger 5KV and 10KV insulation resistance testers. Each 10 foot test lead has a test clip for hands-free connection to a conductor. Silicone insulation on the lead wires and test clips helps protect hands from shock and...


More Info
Megger BITE5 Battery Tester

Battery Testers

$5,245.00 CAD
{"id":8514393112766,"title":"Megger BITE5 Battery Tester","handle":"megger-bite5-battery-tester","description":"\u003cp\u003eThe \u003cstrong\u003eBITE5\u003c\/strong\u003e is a battery tester that tests lead acid batteries, NiCD batteries as well as lithium-ion batteries. It will measure and record battery voltage, impedance, and temperature, and also supports discharge testing. The BITE5 will measure the voltage, current, impedance and temperature throughout the discharge cycle. See the \u003cstrong\u003eBITE5-ADV\u003c\/strong\u003e Advanced model for even more features!\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cdiv data-loaded=\"true\" data-page-number=\"1\" class=\"page\"\u003e\n\u003cdiv class=\"textLayer\"\u003e\n\u003cul\u003e\n\u003cli\u003e Supports battery discharge testing\u003c\/li\u003e\n\u003cli\u003eMeasures impedance on cells up to 200 V\u003c\/li\u003e\n\u003cli\u003eSupports lead acid, NiCD and lithium-ion\u003c\/li\u003e\n\u003cli\u003eMeasures DC voltages up to 1000 V\u003c\/li\u003e\n\u003cli\u003eMeasures AC voltages up to 600 V\u003c\/li\u003e\n\u003cli\u003eTouch screen set-up and trending USB and micro SD card\u003c\/li\u003e\n\u003cli\u003eMeasures AC and DC current\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-loaded=\"true\" data-page-number=\"2\" class=\"page\"\u003e\n\u003cdiv class=\"textLayer\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003enput Power\u003c\/td\u003e\n\u003ctd\u003eAC\/adapter\u003cbr\u003eInput 100 to 240 V AC (50\/60 Hz)\u003cbr\u003eOutput 12 V DC at 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eLi-ion rechargeable pack: \u0026gt;5.4 Ah\u003cbr\u003eVoltage rating: 7.4 V\u003cbr\u003eCharge time: 4 hours\u003cbr\u003eBattery life: \u0026gt;8 hours\u003cbr\u003e300 charge\/discharge cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Impedance\u003c\/td\u003e\n\u003ctd\u003eRange: 3, 30, 300 mΩ and 3, 30, 300 Ω\u003cbr\u003eResolution: 1, 10, 100μΩ and 1, 10, 100 mΩ\u003cbr\u003eAccuracy: ±1% of reading ±10 digits; ±0.8% of reading ±10 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage DC\/AC\u003c\/td\u003e\n\u003ctd\u003eRange: 5, 50, 500 V DC and 5, 50, 500, 600 V AC\u003cbr\u003eResolution: 0.001, 0.01, 0.1, 1 V\u003cbr\u003eAccuracy: ±0.5% of readings ±5 digits (for V DC range); ±0.75% of readings ±10 digits (for V AC range) 40 to 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC\/AC\u003c\/td\u003e\n\u003ctd\u003eRange: 4, 40, 400, 1000 A DC and 4, 40, 400, 1000 A AC\u003cbr\u003eResolution: 0.001, 0.01, 0.1, 1 A\u003cbr\u003eAccuracy: ±0.5% of readings ±5 digits + (CT tolerance) (for A DC range); ±0.75% of readings ±10 digits (for A AC range) + (CT tolerance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eRange: 10 to 100°C\u003cbr\u003eResolution: 0.1°C\u003cbr\u003eAccuracy: ±1°C ±2 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple Voltage\u003c\/td\u003e\n\u003ctd\u003eRange: 0 to 5 V\u003cbr\u003eResolution: 0.001 V\u003cbr\u003eAccuracy: ±0.5% of readings ±10 digits (40 Hz to 100 KHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e0.1%, 2 σ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Capacity\u003c\/td\u003e\n\u003ctd\u003eMemory: 8 to 16 G flash storage\u003cbr\u003eImpedance record: Max 1000 records\u003cbr\u003eVA record: Maximum 512 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBattery Tester\u003c\/li\u003e\n\u003cli\u003eDuplex Probes (with Temperature Probe)\u003c\/li\u003e\n\u003cli\u003eVoltage Test Leads\u003c\/li\u003e\n\u003cli\u003eCharger\u003c\/li\u003e\n\u003cli\u003eNeck Strap\u003c\/li\u003e\n\u003cli\u003eZero Bar\u003c\/li\u003e\n\u003cli\u003eMicro SD Card\u003c\/li\u003e\n\u003cli\u003eMicro SD Card USB Reader\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003cli\u003eStylus\u003c\/li\u003e\n\u003cli\u003eCarry Bag\u003c\/li\u003e\n\u003cli\u003ePouch Bag\u003c\/li\u003e\n\u003cli\u003e\u003cbr\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_Bite_5_Battery_Tester_Datasheet_-_2024.pdf?v=1750872447\" target=\"_blank\" title=\"Megger BITE5 Battery Tester Spec Sheet\" rel=\"noopener\"\u003eMegger BITE5 Battery Tester Spec Sheet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_TDR2050_Datasheet.pdf?v=1750871624\" title=\"Megger TDR2050 Two Channel Cable Fault Locator Spec Sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e","published_at":"2025-06-25T11:16:57-06:00","created_at":"2025-06-25T11:16:57-06:00","vendor":"Megger","type":"Battery Testers","tags":[],"price":524500,"price_min":524500,"price_max":524500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":45174009397438,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-BITE5","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger BITE5 Battery Tester","public_title":null,"options":["Default Title"],"price":524500,"weight":1814,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerBITE5.png?v=1750871985"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerBITE5.png?v=1750871985","options":["Title"],"media":[{"alt":null,"id":30122970153150,"position":1,"preview_image":{"aspect_ratio":1.046,"height":459,"width":480,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerBITE5.png?v=1750871985"},"aspect_ratio":1.046,"height":459,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerBITE5.png?v=1750871985","width":480}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe \u003cstrong\u003eBITE5\u003c\/strong\u003e is a battery tester that tests lead acid batteries, NiCD batteries as well as lithium-ion batteries. It will measure and record battery voltage, impedance, and temperature, and also supports discharge testing. The BITE5 will measure the voltage, current, impedance and temperature throughout the discharge cycle. See the \u003cstrong\u003eBITE5-ADV\u003c\/strong\u003e Advanced model for even more features!\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cdiv data-loaded=\"true\" data-page-number=\"1\" class=\"page\"\u003e\n\u003cdiv class=\"textLayer\"\u003e\n\u003cul\u003e\n\u003cli\u003e Supports battery discharge testing\u003c\/li\u003e\n\u003cli\u003eMeasures impedance on cells up to 200 V\u003c\/li\u003e\n\u003cli\u003eSupports lead acid, NiCD and lithium-ion\u003c\/li\u003e\n\u003cli\u003eMeasures DC voltages up to 1000 V\u003c\/li\u003e\n\u003cli\u003eMeasures AC voltages up to 600 V\u003c\/li\u003e\n\u003cli\u003eTouch screen set-up and trending USB and micro SD card\u003c\/li\u003e\n\u003cli\u003eMeasures AC and DC current\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-loaded=\"true\" data-page-number=\"2\" class=\"page\"\u003e\n\u003cdiv class=\"textLayer\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003enput Power\u003c\/td\u003e\n\u003ctd\u003eAC\/adapter\u003cbr\u003eInput 100 to 240 V AC (50\/60 Hz)\u003cbr\u003eOutput 12 V DC at 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eLi-ion rechargeable pack: \u0026gt;5.4 Ah\u003cbr\u003eVoltage rating: 7.4 V\u003cbr\u003eCharge time: 4 hours\u003cbr\u003eBattery life: \u0026gt;8 hours\u003cbr\u003e300 charge\/discharge cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Impedance\u003c\/td\u003e\n\u003ctd\u003eRange: 3, 30, 300 mΩ and 3, 30, 300 Ω\u003cbr\u003eResolution: 1, 10, 100μΩ and 1, 10, 100 mΩ\u003cbr\u003eAccuracy: ±1% of reading ±10 digits; ±0.8% of reading ±10 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage DC\/AC\u003c\/td\u003e\n\u003ctd\u003eRange: 5, 50, 500 V DC and 5, 50, 500, 600 V AC\u003cbr\u003eResolution: 0.001, 0.01, 0.1, 1 V\u003cbr\u003eAccuracy: ±0.5% of readings ±5 digits (for V DC range); ±0.75% of readings ±10 digits (for V AC range) 40 to 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent DC\/AC\u003c\/td\u003e\n\u003ctd\u003eRange: 4, 40, 400, 1000 A DC and 4, 40, 400, 1000 A AC\u003cbr\u003eResolution: 0.001, 0.01, 0.1, 1 A\u003cbr\u003eAccuracy: ±0.5% of readings ±5 digits + (CT tolerance) (for A DC range); ±0.75% of readings ±10 digits (for A AC range) + (CT tolerance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eRange: 10 to 100°C\u003cbr\u003eResolution: 0.1°C\u003cbr\u003eAccuracy: ±1°C ±2 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple Voltage\u003c\/td\u003e\n\u003ctd\u003eRange: 0 to 5 V\u003cbr\u003eResolution: 0.001 V\u003cbr\u003eAccuracy: ±0.5% of readings ±10 digits (40 Hz to 100 KHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e0.1%, 2 σ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Capacity\u003c\/td\u003e\n\u003ctd\u003eMemory: 8 to 16 G flash storage\u003cbr\u003eImpedance record: Max 1000 records\u003cbr\u003eVA record: Maximum 512 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBattery Tester\u003c\/li\u003e\n\u003cli\u003eDuplex Probes (with Temperature Probe)\u003c\/li\u003e\n\u003cli\u003eVoltage Test Leads\u003c\/li\u003e\n\u003cli\u003eCharger\u003c\/li\u003e\n\u003cli\u003eNeck Strap\u003c\/li\u003e\n\u003cli\u003eZero Bar\u003c\/li\u003e\n\u003cli\u003eMicro SD Card\u003c\/li\u003e\n\u003cli\u003eMicro SD Card USB Reader\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003cli\u003eStylus\u003c\/li\u003e\n\u003cli\u003eCarry Bag\u003c\/li\u003e\n\u003cli\u003ePouch Bag\u003c\/li\u003e\n\u003cli\u003e\u003cbr\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_Bite_5_Battery_Tester_Datasheet_-_2024.pdf?v=1750872447\" target=\"_blank\" title=\"Megger BITE5 Battery Tester Spec Sheet\" rel=\"noopener\"\u003eMegger BITE5 Battery Tester Spec Sheet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_TDR2050_Datasheet.pdf?v=1750871624\" title=\"Megger TDR2050 Two Channel Cable Fault Locator Spec Sheet\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e"}
Megger BITE5 Battery Tester

Megger BITE5 Battery Tester

$5,245.00 CAD

The BITE5 is a battery tester that tests lead acid batteries, NiCD batteries as well as lithium-ion batteries. It will measure and record battery voltage, impedance, and temperature, and also supports discharge testing. The BITE5 will measure the voltage, current, impedance and temperature throughout the discharge cycle. See the BITE5-ADV Advanc...


More Info
Megger BITE5-ADV Advanced Battery Tester

Battery Testers

$9,250.00 CAD
{"id":8514408251582,"title":"Megger BITE5-ADV Advanced Battery Tester","handle":"megger-bite5-adv-advanced-battery-tester","description":"\u003cp\u003eThe \u003cstrong\u003eBITE5 Advanced\u003c\/strong\u003e is a battery tester that will test lead acid batteries, NiCD batteries as well as lithium-ion batteries. It will measure and record battery voltage, impedance, temperature and inter-cell connections. The BITE5 Advanced also supports discharge testing. It will measure the voltage, current, impedance and temperature throughout the discharge cycle. \u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cdiv class=\"page\" data-page-number=\"1\" data-loaded=\"true\"\u003e\n\u003cdiv class=\"textLayer\"\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures impedance on modules up to 500 V  \u003c\/li\u003e\n\u003cli\u003eMeasures inter-cell (strap) resistance  \u003c\/li\u003e\n\u003cli\u003eSupports lead acid, NiCD and lithium-ion\u003c\/li\u003e\n\u003cli\u003eSupports battery discharge testing\u003c\/li\u003e\n\u003cli\u003eMonitoring battery recharge\u003c\/li\u003e\n\u003cli\u003eTest parallel strings without segmenting\u003c\/li\u003e\n\u003cli\u003eTouch screen set-up and trending\u003c\/li\u003e\n\u003cli\u003eRFID Tag Reader \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page\" data-page-number=\"2\" data-loaded=\"true\"\u003e\n\u003cdiv class=\"textLayer\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC\/Adapter\u003c\/td\u003e\n\u003ctd\u003eInput: 100 to 240 V AC (50\/60 Hz)\u003cbr\u003eOutput: 12 V DC at 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eLi-ion rechargeable pack: \u0026gt;5.2 Ah\u003cbr\u003eVoltage rating: 7.2 V\u003cbr\u003eCharge time: 4 hours\u003cbr\u003eBattery life: \u0026gt;8 hours\u003cbr\u003e300 charge\/discharge cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInternal Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003emΩ: 3, 30, and 300\u003cbr\u003eΩ: 3, 30 and 300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eμΩ: 1, 10 and 100\u003cbr\u003emΩ: 1, 10 and 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading ±10 digits\u003cbr\u003e±0.8% of reading ±10 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVoltage DC\/AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eV DC:\u003cbr\u003e5, 50, 500 and 1000\u003cbr\u003e\u003cbr\u003eV AC:\u003cbr\u003e5, 50, 500 and 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001, 0.01, 0.1 and 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eDC: ±0.5% of reading ±5 digits\u003cbr\u003eAC: ±0.75% of reading ±10 digits (40 to 100 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCurrent DC\/AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eA DC: 4, 40, 400, 1000\u003cbr\u003eA AC: 4, 40, 400, 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001, 0.01, 0.1 and 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eA DC:\u003cbr\u003e±0.5% of reading ±1 digit + (CT Tolerance)\u003cbr\u003e±0.5% of reading ±5 digits + (CT Tolerance)\u003cbr\u003e\u003cbr\u003eA AC:\u003cbr\u003e±0.75% of reading ±1 digit + (CT Tolerance)\u003cbr\u003e±0.75% of reading ±10 digits + (CT Tolerance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOthers Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eRange: 50 to 212°F (10 to 100°C)\u003cbr\u003eResolution: 0.18°F (0.1°C)\u003cbr\u003eAccuracy: 1.8°F (±1°C) ±2 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple Voltage\u003c\/td\u003e\n\u003ctd\u003eRange: 0 to 5 V\u003cbr\u003eResolution: 0.001 V\u003cbr\u003eAccuracy: ±0.5% of reading ±10 digits (40 to 10 KHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e0.1%, 2 σ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Capacity Memory\u003c\/td\u003e\n\u003ctd\u003e8 up to 16 GB flash storage\u003cbr\u003eImpedance record: Maximum 1000 records\u003cbr\u003eVA record: Maximum 512 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBattery Tester\u003c\/li\u003e\n\u003cli\u003eDuplex Probes (with temperature probe)\u003c\/li\u003e\n\u003cli\u003eVoltage Test Leads\u003c\/li\u003e\n\u003cli\u003eCharger\u003c\/li\u003e\n\u003cli\u003eShoulder Strap\u003c\/li\u003e\n\u003cli\u003eZero Bar\u003c\/li\u003e\n\u003cli\u003e16 GB MicroSD Card\u003c\/li\u003e\n\u003cli\u003eMicroSD Card USB Reader\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003cli\u003eStylus\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003cli\u003ePouch Bag\u003c\/li\u003e\n\u003cli\u003eOne-Year Warranty (Conditional Two-Year Warranty)\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_Bite_5_Advanced_Battery_Tester_Datasheet_-_2024.pdf?v=1750872451\" target=\"_blank\" title=\"Megger BITE5-ADV Advanced Battery Tester Spec Sheet\" rel=\"noopener\"\u003eMegger BITE5-ADV Advanced Battery Tester Spec Sheet\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Megger TDR2050 Two Channel Cable Fault Locator Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_TDR2050_Datasheet.pdf?v=1750871624\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e","published_at":"2025-06-25T11:28:20-06:00","created_at":"2025-06-25T11:28:20-06:00","vendor":"Megger","type":"Battery Testers","tags":[],"price":925000,"price_min":925000,"price_max":925000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":45174027878590,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-BITE5-ADV","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger BITE5-ADV Advanced Battery Tester","public_title":null,"options":["Default Title"],"price":925000,"weight":1814,"compare_at_price":null,"inventory_management":"shopify","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerBITE5.png?v=1750871985"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerBITE5.png?v=1750871985","options":["Title"],"media":[{"alt":null,"id":30122970153150,"position":1,"preview_image":{"aspect_ratio":1.046,"height":459,"width":480,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerBITE5.png?v=1750871985"},"aspect_ratio":1.046,"height":459,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerBITE5.png?v=1750871985","width":480}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe \u003cstrong\u003eBITE5 Advanced\u003c\/strong\u003e is a battery tester that will test lead acid batteries, NiCD batteries as well as lithium-ion batteries. It will measure and record battery voltage, impedance, temperature and inter-cell connections. The BITE5 Advanced also supports discharge testing. It will measure the voltage, current, impedance and temperature throughout the discharge cycle. \u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cdiv class=\"page\" data-page-number=\"1\" data-loaded=\"true\"\u003e\n\u003cdiv class=\"textLayer\"\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures impedance on modules up to 500 V  \u003c\/li\u003e\n\u003cli\u003eMeasures inter-cell (strap) resistance  \u003c\/li\u003e\n\u003cli\u003eSupports lead acid, NiCD and lithium-ion\u003c\/li\u003e\n\u003cli\u003eSupports battery discharge testing\u003c\/li\u003e\n\u003cli\u003eMonitoring battery recharge\u003c\/li\u003e\n\u003cli\u003eTest parallel strings without segmenting\u003c\/li\u003e\n\u003cli\u003eTouch screen set-up and trending\u003c\/li\u003e\n\u003cli\u003eRFID Tag Reader \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page\" data-page-number=\"2\" data-loaded=\"true\"\u003e\n\u003cdiv class=\"textLayer\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC\/Adapter\u003c\/td\u003e\n\u003ctd\u003eInput: 100 to 240 V AC (50\/60 Hz)\u003cbr\u003eOutput: 12 V DC at 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eLi-ion rechargeable pack: \u0026gt;5.2 Ah\u003cbr\u003eVoltage rating: 7.2 V\u003cbr\u003eCharge time: 4 hours\u003cbr\u003eBattery life: \u0026gt;8 hours\u003cbr\u003e300 charge\/discharge cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eInternal Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003emΩ: 3, 30, and 300\u003cbr\u003eΩ: 3, 30 and 300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eμΩ: 1, 10 and 100\u003cbr\u003emΩ: 1, 10 and 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading ±10 digits\u003cbr\u003e±0.8% of reading ±10 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVoltage DC\/AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eV DC:\u003cbr\u003e5, 50, 500 and 1000\u003cbr\u003e\u003cbr\u003eV AC:\u003cbr\u003e5, 50, 500 and 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001, 0.01, 0.1 and 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eDC: ±0.5% of reading ±5 digits\u003cbr\u003eAC: ±0.75% of reading ±10 digits (40 to 100 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCurrent DC\/AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eA DC: 4, 40, 400, 1000\u003cbr\u003eA AC: 4, 40, 400, 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001, 0.01, 0.1 and 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eA DC:\u003cbr\u003e±0.5% of reading ±1 digit + (CT Tolerance)\u003cbr\u003e±0.5% of reading ±5 digits + (CT Tolerance)\u003cbr\u003e\u003cbr\u003eA AC:\u003cbr\u003e±0.75% of reading ±1 digit + (CT Tolerance)\u003cbr\u003e±0.75% of reading ±10 digits + (CT Tolerance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eOthers Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003eRange: 50 to 212°F (10 to 100°C)\u003cbr\u003eResolution: 0.18°F (0.1°C)\u003cbr\u003eAccuracy: 1.8°F (±1°C) ±2 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple Voltage\u003c\/td\u003e\n\u003ctd\u003eRange: 0 to 5 V\u003cbr\u003eResolution: 0.001 V\u003cbr\u003eAccuracy: ±0.5% of reading ±10 digits (40 to 10 KHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e0.1%, 2 σ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Capacity Memory\u003c\/td\u003e\n\u003ctd\u003e8 up to 16 GB flash storage\u003cbr\u003eImpedance record: Maximum 1000 records\u003cbr\u003eVA record: Maximum 512 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBattery Tester\u003c\/li\u003e\n\u003cli\u003eDuplex Probes (with temperature probe)\u003c\/li\u003e\n\u003cli\u003eVoltage Test Leads\u003c\/li\u003e\n\u003cli\u003eCharger\u003c\/li\u003e\n\u003cli\u003eShoulder Strap\u003c\/li\u003e\n\u003cli\u003eZero Bar\u003c\/li\u003e\n\u003cli\u003e16 GB MicroSD Card\u003c\/li\u003e\n\u003cli\u003eMicroSD Card USB Reader\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003cli\u003eStylus\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003cli\u003ePouch Bag\u003c\/li\u003e\n\u003cli\u003eOne-Year Warranty (Conditional Two-Year Warranty)\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_Bite_5_Advanced_Battery_Tester_Datasheet_-_2024.pdf?v=1750872451\" target=\"_blank\" title=\"Megger BITE5-ADV Advanced Battery Tester Spec Sheet\" rel=\"noopener\"\u003eMegger BITE5-ADV Advanced Battery Tester Spec Sheet\u003c\/a\u003e\u003ca rel=\"noopener\" title=\"Megger TDR2050 Two Channel Cable Fault Locator Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_TDR2050_Datasheet.pdf?v=1750871624\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e"}
Megger BITE5-ADV Advanced Battery Tester

Megger BITE5-ADV Advanced Battery Tester

$9,250.00 CAD

The BITE5 Advanced is a battery tester that will test lead acid batteries, NiCD batteries as well as lithium-ion batteries. It will measure and record battery voltage, impedance, temperature and inter-cell connections. The BITE5 Advanced also supports discharge testing. It will measure the voltage, current, impedance and temperature throughout t...


More Info
Megger BM5200 5kV Insulation Tester

Insulation Testers

$3,650.00 CAD
{"id":1838193573931,"title":"Megger BM5200 5kV Insulation Tester","handle":"megger-bm5200-5kv-insulation-tester","description":"\u003cp\u003eMegger BM5200 is a battery powered insulation tester with digital and analogue arc display, designed for high voltage insulation resistance testing in the maintenance and servicing of cables, rotating plant machinery, transformers, switchgear and industrial applications.\u003c\/p\u003e\n\u003cp\u003eDC insulation tests are performed at 250 V, 500 V, 1000 V, 2500 V, 5000 V. Insulation resistance measuring range is 100 k Ω to 1000 G Ω. Automatic discharge for capacitive circuits under test is provided and decaying voltage displayed.\u003c\/p\u003e\n\u003cp\u003eThe guard terminal can be used to minimize the effects of surface leakage and hence erroneous measurements when carrying out insulation resistance tests.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 TΩ, 1.4 mA, 5 kV Compact, rugged insulation tester with digital and analogue display\u003c\/li\u003e\n\u003cli\u003eFive test ranges; 250 V, 500 V, 1000 V, 2500 V and 5000 V\u003c\/li\u003e\n\u003cli\u003eInsulation (InS), Polarisation Index (PI) and variable timed test (t) modes\u003c\/li\u003e\n\u003cli\u003eGuard terminal to shunt surface leakage currents\u003c\/li\u003e\n\u003cli\u003eSelectable DC or AC (incl. frequency) voltmeter functions\u003c\/li\u003e\n\u003cli\u003eHigh voltage warning indicator\u003c\/li\u003e\n\u003cli\u003eExternal voltage display after IR test\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge of reactive loads and test leads\u003c\/li\u003e\n\u003cli\u003eCATIII 600 V safety rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProduct test and qualification\u003c\/li\u003e\n\u003cli\u003eInstallation of equipment\u003c\/li\u003e\n\u003cli\u003eRoutine maintenance\u003c\/li\u003e\n\u003cli\u003eProblem resolutions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation range\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 1 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal test voltages\u003c\/td\u003e\n\u003ctd\u003e250 V, 500 V, 1000 V, 2500 V, 5000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal voltage accuracy\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1000 V 0...+10% of nominal test voltage\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e≥1000 V 0...+5% of nominal test voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation accuracy\u003c\/td\u003e\n\u003ctd\u003eUp to 1 GΩ: All ranges ±5% ±2 digits\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eOver 1 GΩ:\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5000 V ±5% ±0.04% per GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e2500 V ±5% ±0.08% per GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e1000 V ±5% ±0.2% per GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e500 V ±5% ±0.4% per GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e250 V ±5% ±0.8% per GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit\/charge current\u003c\/td\u003e\n\u003ctd\u003e1.4 mA ±0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum capacitance of load\u003c\/td\u003e\n\u003ctd\u003e5 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter accuracy\u003c\/td\u003e\n\u003ctd\u003e3% ± 3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency measurement\u003c\/td\u003e\n\u003ctd\u003e45 Hz to 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency measurement accuracy\u003c\/td\u003e\n\u003ctd\u003e±2 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter range\u003c\/td\u003e\n\u003ctd\u003eUp to 600 V a.c. or d.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e8 x LR6\/AA batteries (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e5 lbs (2.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 hours @ 5 kV into 100 MΩ with AA Alkaline LR6\u003c\/td\u003e\n\u003ctd\u003e5 lbs (2.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuard\u003c\/td\u003e\n\u003ctd\u003e2% error guarding 5 MΩ leakage on 100 MΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range and humidity\u003c\/td\u003e\n\u003ctd\u003e-20 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e90% RH, 0 to 40 °C\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e70% RH, 40 to 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature range\u003c\/td\u003e\n\u003ctd\u003e-20 to +65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety protection\u003c\/td\u003e\n\u003ctd\u003eInsulation Cat III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eThe product conforms to IEC 61326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220 mm x 115 mm x 163 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMegger BM5200 Insulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eCarrying case with lead storage\u003c\/li\u003e\n\u003cli\u003eBattery 1.5V alkaline AA (x8)\u003c\/li\u003e\n\u003cli\u003e3 m lead set, medium size insulated clips\u003c\/li\u003e\n\u003cli\u003eUser guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_-_BM5200.pdf?1598\" target=\"_blank\" title=\"Megger BM5200 Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger BM5200 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-07-22T14:19:22-06:00","created_at":"2019-07-22T14:23:53-06:00","vendor":"Megger","type":"Insulation Testers","tags":[],"price":365000,"price_min":365000,"price_max":365000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16793588432939,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-BM5200","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger BM5200 5kV Insulation Tester","public_title":null,"options":["Default Title"],"price":365000,"weight":3629,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-bm5200.jpg?v=1563827036"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-bm5200.jpg?v=1563827036","options":["Title"],"media":[{"alt":null,"id":2804065599531,"position":1,"preview_image":{"aspect_ratio":1.0,"height":700,"width":700,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-bm5200.jpg?v=1563827036"},"aspect_ratio":1.0,"height":700,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-bm5200.jpg?v=1563827036","width":700}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eMegger BM5200 is a battery powered insulation tester with digital and analogue arc display, designed for high voltage insulation resistance testing in the maintenance and servicing of cables, rotating plant machinery, transformers, switchgear and industrial applications.\u003c\/p\u003e\n\u003cp\u003eDC insulation tests are performed at 250 V, 500 V, 1000 V, 2500 V, 5000 V. Insulation resistance measuring range is 100 k Ω to 1000 G Ω. Automatic discharge for capacitive circuits under test is provided and decaying voltage displayed.\u003c\/p\u003e\n\u003cp\u003eThe guard terminal can be used to minimize the effects of surface leakage and hence erroneous measurements when carrying out insulation resistance tests.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 TΩ, 1.4 mA, 5 kV Compact, rugged insulation tester with digital and analogue display\u003c\/li\u003e\n\u003cli\u003eFive test ranges; 250 V, 500 V, 1000 V, 2500 V and 5000 V\u003c\/li\u003e\n\u003cli\u003eInsulation (InS), Polarisation Index (PI) and variable timed test (t) modes\u003c\/li\u003e\n\u003cli\u003eGuard terminal to shunt surface leakage currents\u003c\/li\u003e\n\u003cli\u003eSelectable DC or AC (incl. frequency) voltmeter functions\u003c\/li\u003e\n\u003cli\u003eHigh voltage warning indicator\u003c\/li\u003e\n\u003cli\u003eExternal voltage display after IR test\u003c\/li\u003e\n\u003cli\u003eAutomatic discharge of reactive loads and test leads\u003c\/li\u003e\n\u003cli\u003eCATIII 600 V safety rating\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProduct test and qualification\u003c\/li\u003e\n\u003cli\u003eInstallation of equipment\u003c\/li\u003e\n\u003cli\u003eRoutine maintenance\u003c\/li\u003e\n\u003cli\u003eProblem resolutions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation range\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 1 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal test voltages\u003c\/td\u003e\n\u003ctd\u003e250 V, 500 V, 1000 V, 2500 V, 5000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal voltage accuracy\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1000 V 0...+10% of nominal test voltage\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e≥1000 V 0...+5% of nominal test voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation accuracy\u003c\/td\u003e\n\u003ctd\u003eUp to 1 GΩ: All ranges ±5% ±2 digits\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eOver 1 GΩ:\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5000 V ±5% ±0.04% per GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e2500 V ±5% ±0.08% per GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e1000 V ±5% ±0.2% per GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e500 V ±5% ±0.4% per GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e250 V ±5% ±0.8% per GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit\/charge current\u003c\/td\u003e\n\u003ctd\u003e1.4 mA ±0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum capacitance of load\u003c\/td\u003e\n\u003ctd\u003e5 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter accuracy\u003c\/td\u003e\n\u003ctd\u003e3% ± 3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency measurement\u003c\/td\u003e\n\u003ctd\u003e45 Hz to 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency measurement accuracy\u003c\/td\u003e\n\u003ctd\u003e±2 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter range\u003c\/td\u003e\n\u003ctd\u003eUp to 600 V a.c. or d.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e8 x LR6\/AA batteries (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e5 lbs (2.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 hours @ 5 kV into 100 MΩ with AA Alkaline LR6\u003c\/td\u003e\n\u003ctd\u003e5 lbs (2.3 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuard\u003c\/td\u003e\n\u003ctd\u003e2% error guarding 5 MΩ leakage on 100 MΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range and humidity\u003c\/td\u003e\n\u003ctd\u003e-20 to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e90% RH, 0 to 40 °C\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e70% RH, 40 to 55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature range\u003c\/td\u003e\n\u003ctd\u003e-20 to +65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety protection\u003c\/td\u003e\n\u003ctd\u003eInsulation Cat III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eThe product conforms to IEC 61326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220 mm x 115 mm x 163 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMegger BM5200 Insulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eCarrying case with lead storage\u003c\/li\u003e\n\u003cli\u003eBattery 1.5V alkaline AA (x8)\u003c\/li\u003e\n\u003cli\u003e3 m lead set, medium size insulated clips\u003c\/li\u003e\n\u003cli\u003eUser guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_-_BM5200.pdf?1598\" target=\"_blank\" title=\"Megger BM5200 Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger BM5200 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger BM5200 5kV Insulation Tester

Megger BM5200 5kV Insulation Tester

$3,650.00 CAD

Megger BM5200 is a battery powered insulation tester with digital and analogue arc display, designed for high voltage insulation resistance testing in the maintenance and servicing of cables, rotating plant machinery, transformers, switchgear and industrial applications. DC insulation tests are performed at 250 V, 500 V, 1000 V, 2500 V, 5000 V. ...


More Info
Megger CHM Series Cable Height Meters

Cable Height Meters

From $1,165.00 CAD
{"id":1843237552171,"title":"Megger CHM Series Cable Height Meters","handle":"megger-chm-series-cable-height-meters","description":"\u003cp\u003eThe CHM Series of Cable Height Meters utilize ultrasonic sound to determine the height of up to six overhead cables and wires. The instruments are designed to address specific measuring requirements on cables up to 75 feet (23 m). The CHM600 (50 Feet) and CHM600E (75 Feet) are designed primarily for power cable applications, while the CHM2000 (35 Feet) is designed for telecommunication applications.\u003c\/p\u003e\n\u003cp\u003eThe Cable Height Meters emit short bursts of sound which originate from the cone shaped transmitter. The microprocessor in the instruments calculates the elapsed time for the bursts of sound to be reflected from the cable back to the instruments. The result can be displayed in either feet and inches or meters. However, before the final measurement can be displayed, the air temperature must be measured because the speed of sound varies at approximately 0.2 percent per degree Celsius.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDramatically reduces measuring time\u003c\/li\u003e\n\u003cli\u003eInherently safe\u003c\/li\u003e\n\u003cli\u003eDesigned for ease-of-use\u003c\/li\u003e\n\u003cli\u003eHand-held portability\u003c\/li\u003e\n\u003cli\u003eCalibration and maintenance free operation\u003c\/li\u003e\n\u003cli\u003eNo physical connection to cables or wires\u003c\/li\u003e\n\u003cli\u003eMeasures the height of up to six overhead cables\u003c\/li\u003e\n\u003cli\u003eAvailable in alternate configurations\u003c\/li\u003e\n\u003cli\u003eMeasurements up to 75 ft.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTelephone lines\u003c\/li\u003e\n\u003cli\u003eDistribution lines\u003c\/li\u003e\n\u003cli\u003eTransmission lines\u003c\/li\u003e\n\u003cli\u003eCable television (installers and contractors)\u003c\/li\u003e\n\u003cli\u003eStreet lights\u003c\/li\u003e\n\u003cli\u003eSag (lowest point to ground)\u003c\/li\u003e\n\u003cli\u003eSeparation between up to six cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003ein. (5 mm) if \u0026lt; 10 m, 1\/2 in. (10 mm) if \u0026gt; 10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eTypically less than 0.5% error ±2 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower source\u003c\/td\u003e\n\u003ctd\u003e9 volt alkaline leak-proof battery (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e14º F to 104º F (-10º C to 40º C) with compensation over the full range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50,000 Measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCable height meter\u003c\/li\u003e\n\u003cli\u003e9 V Battery\u003c\/li\u003e\n\u003cli\u003eInstructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_CHM600-600E-2000_Spec_sheet.pdf?1685\" target=\"_blank\" title=\"Megger CHM Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger CHM Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-07-29T13:34:17-06:00","created_at":"2019-07-29T13:40:16-06:00","vendor":"Megger","type":"Cable Height Meters","tags":[],"price":116500,"price_min":116500,"price_max":152500,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16822531227691,"title":"MEG-CHM600E","option1":"MEG-CHM600E","option2":null,"option3":null,"sku":"MEG-CHM600E","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger CHM Series Cable Height Meters - MEG-CHM600E","public_title":"MEG-CHM600E","options":["MEG-CHM600E"],"price":152500,"weight":454,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16822531260459,"title":"MEG-CHM2000","option1":"MEG-CHM2000","option2":null,"option3":null,"sku":"MEG-CHM2000","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger CHM Series Cable Height Meters - MEG-CHM2000","public_title":"MEG-CHM2000","options":["MEG-CHM2000"],"price":116500,"weight":454,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16822531293227,"title":"MEG-CHM600","option1":"MEG-CHM600","option2":null,"option3":null,"sku":"MEG-CHM600","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger CHM Series Cable Height Meters - MEG-CHM600","public_title":"MEG-CHM600","options":["MEG-CHM600"],"price":133500,"weight":454,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_CHM600E_27ba736d-21cf-4c3c-a3bf-299099273cfd.jpg?v=1564429272"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_CHM600E_27ba736d-21cf-4c3c-a3bf-299099273cfd.jpg?v=1564429272","options":["Model"],"media":[{"alt":null,"id":2811098791979,"position":1,"preview_image":{"aspect_ratio":0.773,"height":3361,"width":2597,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_CHM600E_27ba736d-21cf-4c3c-a3bf-299099273cfd.jpg?v=1564429272"},"aspect_ratio":0.773,"height":3361,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_CHM600E_27ba736d-21cf-4c3c-a3bf-299099273cfd.jpg?v=1564429272","width":2597}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe CHM Series of Cable Height Meters utilize ultrasonic sound to determine the height of up to six overhead cables and wires. The instruments are designed to address specific measuring requirements on cables up to 75 feet (23 m). The CHM600 (50 Feet) and CHM600E (75 Feet) are designed primarily for power cable applications, while the CHM2000 (35 Feet) is designed for telecommunication applications.\u003c\/p\u003e\n\u003cp\u003eThe Cable Height Meters emit short bursts of sound which originate from the cone shaped transmitter. The microprocessor in the instruments calculates the elapsed time for the bursts of sound to be reflected from the cable back to the instruments. The result can be displayed in either feet and inches or meters. However, before the final measurement can be displayed, the air temperature must be measured because the speed of sound varies at approximately 0.2 percent per degree Celsius.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDramatically reduces measuring time\u003c\/li\u003e\n\u003cli\u003eInherently safe\u003c\/li\u003e\n\u003cli\u003eDesigned for ease-of-use\u003c\/li\u003e\n\u003cli\u003eHand-held portability\u003c\/li\u003e\n\u003cli\u003eCalibration and maintenance free operation\u003c\/li\u003e\n\u003cli\u003eNo physical connection to cables or wires\u003c\/li\u003e\n\u003cli\u003eMeasures the height of up to six overhead cables\u003c\/li\u003e\n\u003cli\u003eAvailable in alternate configurations\u003c\/li\u003e\n\u003cli\u003eMeasurements up to 75 ft.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTelephone lines\u003c\/li\u003e\n\u003cli\u003eDistribution lines\u003c\/li\u003e\n\u003cli\u003eTransmission lines\u003c\/li\u003e\n\u003cli\u003eCable television (installers and contractors)\u003c\/li\u003e\n\u003cli\u003eStreet lights\u003c\/li\u003e\n\u003cli\u003eSag (lowest point to ground)\u003c\/li\u003e\n\u003cli\u003eSeparation between up to six cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003ein. (5 mm) if \u0026lt; 10 m, 1\/2 in. (10 mm) if \u0026gt; 10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eTypically less than 0.5% error ±2 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower source\u003c\/td\u003e\n\u003ctd\u003e9 volt alkaline leak-proof battery (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e14º F to 104º F (-10º C to 40º C) with compensation over the full range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50,000 Measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCable height meter\u003c\/li\u003e\n\u003cli\u003e9 V Battery\u003c\/li\u003e\n\u003cli\u003eInstructions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_CHM600-600E-2000_Spec_sheet.pdf?1685\" target=\"_blank\" title=\"Megger CHM Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger CHM Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger CHM Series Cable Height Meters

Megger CHM Series Cable Height Meters

$1,335.00 CAD

The CHM Series of Cable Height Meters utilize ultrasonic sound to determine the height of up to six overhead cables and wires. The instruments are designed to address specific measuring requirements on cables up to 75 feet (23 m). The CHM600 (50 Feet) and CHM600E (75 Feet) are designed primarily for power cable applications, while the CHM2000 (3...


More Info
{"id":8372612628670,"title":"Megger DET2\/3-ETK-100M Advanced Earth-Ground Tester with 100M Reel Kit","handle":"megger-det2-3-etk-100m-advanced-earth-ground-tester-with-100m-reel-kit","description":"\u003cp\u003eThe DET2\/3 high resolution earth tester is a robust and compact automatic ground test instrument designed to measure earth electrode resistance and soil resistivity. For use on large or more complex earth systems, which include communications earth systems and difficult test environments, it can be used to test in accordance with BS 7430 (grounding), BS-EN-62305 (lightning protection), BS-EN-50122-1 (railway applications), and IEEE Standard 81.\u003c\/p\u003e\n\u003cp\u003eTest frequency, test current, and filtering can be quickly and easily adjusted so that adverse conditions, which can influence the test, can be overcome, and a wide band of test current frequencies, with a resolution of 0.5 Hz, can be used to eliminate errors caused by noise in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh resolution of 1 mΩ, ideal for large ground systems\u003c\/li\u003e\n\u003cli\u003eVersatile tests modes\u003c\/li\u003e\n\u003cli\u003eHigh accuracy for ground electrode grid and soil resistivity tests\u003c\/li\u003e\n\u003cli\u003eRechargeable battery power that can last all day with a fast re-charge (up to 10 hours)\u003c\/li\u003e\n\u003cli\u003eRobust instrument with IP65 protection\u003c\/li\u003e\n\u003cli\u003eAutomatic test frequency selection, with filters and high current features\u003c\/li\u003e\n\u003cli\u003eDiagnostic trace display\u003c\/li\u003e\n\u003cli\u003eData storage\u003c\/li\u003e\n\u003cli\u003eLarge colour display that shows numeric and graphical results\u003c\/li\u003e\n\u003cli\u003eOptional earth testing kit (ETK) available\u003c\/li\u003e\n\u003cli\u003e\u003cbr\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"height: 845.54px; width: 550px;\" width=\"920\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 172.543px;\"\u003e2, 3, and 4 Pole Resistance Measurements\u003c\/td\u003e\n\u003ctd style=\"width: 178.452px;\"\u003eRange: 0.001 Ω to 20 kΩ auto range\u003cbr\u003eDisplay: 4-digit display\u003cbr\u003eAccuracy:±0.5% pf reading ±2 digits at 73.4°F (23°C) ±35.6°F (2°C)\u003cbr\u003e\u003cbr\u003eOperational uncertainty: ±2% of reading, ±2 digits (meets IEC61557 operational uncertainty requirements with readings over 10 mΩ) when spike resistances are below 100 Ω ±5% of reading\u003cbr\u003e±2 digits ±10 mΩ (meets IEC61557 operational uncertainty requirements with readings over 10 mΩ)\u003cbr\u003e\u003cbr\u003eTest:\u003cbr\u003eStandards - BS 7430 (grounding)\u003cbr\u003eBS 62305 (lightning)\u003cbr\u003eBS 50122 (railway)\u003cbr\u003eFrequency - 10 to 200 Hz in steps of 0.5 Hz\u003cbr\u003eCurrent - 50 mA maximum\u003cbr\u003e\u003cbr\u003eMaximum output voltage: Less than 50 V rms\u003cbr\u003eMaximum interference: Up to 50 V pk to pk\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 172.543px;\"\u003eStakeless Resistance Measurement\u003c\/td\u003e\n\u003ctd style=\"width: 178.452px;\"\u003eRange: 0.01 to 200 Ω\u003cbr\u003eAccuracy: ±7% accuracy, ±3 digits at 128 Hz\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 172.543px;\"\u003eContinuity\u003c\/td\u003e\n\u003ctd style=\"width: 178.452px;\"\u003eRange: 0.01 to 1 kΩ (3 digits)\u003cbr\u003eAccuracy: ±3% (±2 digits)\u003cbr\u003eTest current: 12 V, 205 mA\u003cbr\u003eLead null: \u0026lt; 10 Ω\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 172.543px;\"\u003eLeakage Current\u003c\/td\u003e\n\u003ctd style=\"width: 178.452px;\"\u003eRange: 0 to 2 A\u003cbr\u003eAccuracy: ±5% (±3 digits)\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 172.543px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"width: 178.452px;\"\u003e5.25\" QWVGA, daylight viewable backlit color\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1989px;\"\u003e\n\u003ctd style=\"height: 55.1989px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1989px;\"\u003e\n\u003ctd style=\"height: 55.1989px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1989px;\"\u003e\n\u003ctd style=\"height: 55.1989px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1989px;\"\u003e\n\u003ctd style=\"height: 55.1989px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1989px;\"\u003e\n\u003ctd style=\"height: 55.1989px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced Earth Ground Tester\u003c\/li\u003e\n\u003cli\u003eCurrent Clamp\u003c\/li\u003e\n\u003cli\u003eVoltage Clamp\u003c\/li\u003e\n\u003cli\u003eCalibration Checker, Instrument\u003c\/li\u003e\n\u003cli\u003eCalibration Checker, Clamps\u003c\/li\u003e\n\u003cli\u003e2 x Reel with 100 m Test Cables\u003c\/li\u003e\n\u003cli\u003e2 x Reel with 60 m Test Cables\u003c\/li\u003e\n\u003cli\u003e4 x Test Spikes\u003c\/li\u003e\n\u003cli\u003e100 m Tape Measure\u003c\/li\u003e\n\u003cli\u003e2 x 1.4 m Leads with Connectors and Clips\u003c\/li\u003e\n\u003cli\u003ePouch\u003c\/li\u003e\n\u003cli\u003eCarry Strap\u003c\/li\u003e\n\u003cli\u003eUser Guide\u003c\/li\u003e\n\u003cli\u003e\u003cbr\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"Megger DET2\/3 Earth Ground Tester Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_DET2-3_Datasheet_2024.pdf?v=1732573459\" target=\"_blank\"\u003eMegger DET2\/3-ETK-100M Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2024-11-25T15:20:24-07:00","created_at":"2024-11-25T15:20:24-07:00","vendor":"Megger","type":"Earth Ground Testers","tags":[],"price":1033500,"price_min":1033500,"price_max":1033500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":44713775005886,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-DET2\/3-ETK-100M","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET2\/3-ETK-100M Advanced Earth-Ground Tester with 100M Reel Kit","public_title":null,"options":["Default Title"],"price":1033500,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"5036175100332","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerDET2-3pic2.jpg?v=1732573588","\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerDET2-3.jpg?v=1732573588"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerDET2-3pic2.jpg?v=1732573588","options":["Title"],"media":[{"alt":null,"id":28845797671102,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerDET2-3pic2.jpg?v=1732573588"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerDET2-3pic2.jpg?v=1732573588","width":1000},{"alt":null,"id":28845797703870,"position":2,"preview_image":{"aspect_ratio":2.504,"height":409,"width":1024,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerDET2-3.jpg?v=1732573588"},"aspect_ratio":2.504,"height":409,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerDET2-3.jpg?v=1732573588","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe DET2\/3 high resolution earth tester is a robust and compact automatic ground test instrument designed to measure earth electrode resistance and soil resistivity. For use on large or more complex earth systems, which include communications earth systems and difficult test environments, it can be used to test in accordance with BS 7430 (grounding), BS-EN-62305 (lightning protection), BS-EN-50122-1 (railway applications), and IEEE Standard 81.\u003c\/p\u003e\n\u003cp\u003eTest frequency, test current, and filtering can be quickly and easily adjusted so that adverse conditions, which can influence the test, can be overcome, and a wide band of test current frequencies, with a resolution of 0.5 Hz, can be used to eliminate errors caused by noise in the earth.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh resolution of 1 mΩ, ideal for large ground systems\u003c\/li\u003e\n\u003cli\u003eVersatile tests modes\u003c\/li\u003e\n\u003cli\u003eHigh accuracy for ground electrode grid and soil resistivity tests\u003c\/li\u003e\n\u003cli\u003eRechargeable battery power that can last all day with a fast re-charge (up to 10 hours)\u003c\/li\u003e\n\u003cli\u003eRobust instrument with IP65 protection\u003c\/li\u003e\n\u003cli\u003eAutomatic test frequency selection, with filters and high current features\u003c\/li\u003e\n\u003cli\u003eDiagnostic trace display\u003c\/li\u003e\n\u003cli\u003eData storage\u003c\/li\u003e\n\u003cli\u003eLarge colour display that shows numeric and graphical results\u003c\/li\u003e\n\u003cli\u003eOptional earth testing kit (ETK) available\u003c\/li\u003e\n\u003cli\u003e\u003cbr\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"height: 845.54px; width: 550px;\" width=\"920\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 172.543px;\"\u003e2, 3, and 4 Pole Resistance Measurements\u003c\/td\u003e\n\u003ctd style=\"width: 178.452px;\"\u003eRange: 0.001 Ω to 20 kΩ auto range\u003cbr\u003eDisplay: 4-digit display\u003cbr\u003eAccuracy:±0.5% pf reading ±2 digits at 73.4°F (23°C) ±35.6°F (2°C)\u003cbr\u003e\u003cbr\u003eOperational uncertainty: ±2% of reading, ±2 digits (meets IEC61557 operational uncertainty requirements with readings over 10 mΩ) when spike resistances are below 100 Ω ±5% of reading\u003cbr\u003e±2 digits ±10 mΩ (meets IEC61557 operational uncertainty requirements with readings over 10 mΩ)\u003cbr\u003e\u003cbr\u003eTest:\u003cbr\u003eStandards - BS 7430 (grounding)\u003cbr\u003eBS 62305 (lightning)\u003cbr\u003eBS 50122 (railway)\u003cbr\u003eFrequency - 10 to 200 Hz in steps of 0.5 Hz\u003cbr\u003eCurrent - 50 mA maximum\u003cbr\u003e\u003cbr\u003eMaximum output voltage: Less than 50 V rms\u003cbr\u003eMaximum interference: Up to 50 V pk to pk\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 172.543px;\"\u003eStakeless Resistance Measurement\u003c\/td\u003e\n\u003ctd style=\"width: 178.452px;\"\u003eRange: 0.01 to 200 Ω\u003cbr\u003eAccuracy: ±7% accuracy, ±3 digits at 128 Hz\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 172.543px;\"\u003eContinuity\u003c\/td\u003e\n\u003ctd style=\"width: 178.452px;\"\u003eRange: 0.01 to 1 kΩ (3 digits)\u003cbr\u003eAccuracy: ±3% (±2 digits)\u003cbr\u003eTest current: 12 V, 205 mA\u003cbr\u003eLead null: \u0026lt; 10 Ω\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 172.543px;\"\u003eLeakage Current\u003c\/td\u003e\n\u003ctd style=\"width: 178.452px;\"\u003eRange: 0 to 2 A\u003cbr\u003eAccuracy: ±5% (±3 digits)\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"width: 172.543px;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"width: 178.452px;\"\u003e5.25\" QWVGA, daylight viewable backlit color\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1989px;\"\u003e\n\u003ctd style=\"height: 55.1989px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1989px;\"\u003e\n\u003ctd style=\"height: 55.1989px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1989px;\"\u003e\n\u003ctd style=\"height: 55.1989px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1989px;\"\u003e\n\u003ctd style=\"height: 55.1989px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 55.1989px;\"\u003e\n\u003ctd style=\"height: 55.1989px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 55.1989px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35.5966px;\"\u003e\n\u003ctd style=\"height: 35.5966px; width: 172.543px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.452px;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"height: 35.5966px; width: 178.494px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced Earth Ground Tester\u003c\/li\u003e\n\u003cli\u003eCurrent Clamp\u003c\/li\u003e\n\u003cli\u003eVoltage Clamp\u003c\/li\u003e\n\u003cli\u003eCalibration Checker, Instrument\u003c\/li\u003e\n\u003cli\u003eCalibration Checker, Clamps\u003c\/li\u003e\n\u003cli\u003e2 x Reel with 100 m Test Cables\u003c\/li\u003e\n\u003cli\u003e2 x Reel with 60 m Test Cables\u003c\/li\u003e\n\u003cli\u003e4 x Test Spikes\u003c\/li\u003e\n\u003cli\u003e100 m Tape Measure\u003c\/li\u003e\n\u003cli\u003e2 x 1.4 m Leads with Connectors and Clips\u003c\/li\u003e\n\u003cli\u003ePouch\u003c\/li\u003e\n\u003cli\u003eCarry Strap\u003c\/li\u003e\n\u003cli\u003eUser Guide\u003c\/li\u003e\n\u003cli\u003e\u003cbr\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"Megger DET2\/3 Earth Ground Tester Datasheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_DET2-3_Datasheet_2024.pdf?v=1732573459\" target=\"_blank\"\u003eMegger DET2\/3-ETK-100M Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger DET2/3-ETK-100M Advanced Earth-Ground Tester with 100M Reel Kit

Megger DET2/3-ETK-100M Advanced Earth-Ground Tester with 100M Reel Kit

$10,335.00 CAD

The DET2/3 high resolution earth tester is a robust and compact automatic ground test instrument designed to measure earth electrode resistance and soil resistivity. For use on large or more complex earth systems, which include communications earth systems and difficult test environments, it can be used to test in accordance with BS 7430 (ground...


More Info
Megger DET3 Series 3-Terminal Digital Ground Tester

Earth Ground Testers

From $1,520.00 CAD
{"id":1843152420907,"title":"Megger DET3 Series 3-Terminal Digital Ground Tester","handle":"megger-det3tc-3-terminal-digital-ground-tester","description":"\u003cp\u003eThe DET3TD is for basic ground testing while the DET3TC includes a current measuring function for ART (Attached Rod Technique) testing capabilities. With this added function, on-site grounds can be tested separately without having to remove the utility connection (as explained further in this document).\u003c\/p\u003e\n\u003cp\u003eBy using the optional ICLAMP with the DET3TC, the user can augment the traditional fall-of-potential measurement method with ART (Attached Rod Technique), which allows electrode testing without disconnection and also leakage current measurements down to 0.5 mA.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIP54 rated\u003c\/li\u003e\n\u003cli\u003e2 and 3 point testing\u003c\/li\u003e\n\u003cli\u003eSelectable 25 V or 50 V output\u003c\/li\u003e\n\u003cli\u003eComplete with lead and stake kit\u003c\/li\u003e\n\u003cli\u003eSimple one button operation\u003c\/li\u003e\n\u003cli\u003eHard carry case\u003c\/li\u003e\n\u003cli\u003eDelivered with calibration certificate\u003c\/li\u003e\n\u003cli\u003eAttached Rod Technique (ART)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"920\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDET3TC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDET3TD\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP54\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP54\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eC Spike Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eP Spike Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNoise Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNoise Rejection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e40 V pk to pk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e40 V pk to pk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e2-Wire Test\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e3-Wire Test\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNo Disconnect Testing (ART)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes, with optional ICLAMP\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEarth Current Range with ICLAMP\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.5 mA to 19.9 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eResistance Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.01 to 2000Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.01 to 2000Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eResistance Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2% ±3 digits\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2% ±3 digits\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEarth Voltage Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0 - 100 V a.c.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0 - 100 V a.c.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEarth Voltage Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2% ±2 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2% ±2 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLCD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLCD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8 off AA cells\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8 off AA cells\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-15 to +55ºC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-15 to +55ºC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40 to +70ºC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40 to +70ºC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEN61010-1 CAT IV 100 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEN61010-1 CAT IV 100 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e203 x 148 x 78 mm (8 x 5.7 x 3.2 inches)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e203 x 148 x 78 mm (8 x 5.7 x 3.2 inches)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e3-Terminal Digital Ground Tester\u003c\/li\u003e\n\u003cli\u003eHard Carry Case\u003c\/li\u003e\n\u003cli\u003eReplacement 3-Wire Lead Set (15m Red Wire, 10m Yellow Wire, 4m Green Wire)\u003c\/li\u003e\n\u003cli\u003e2 x Ground Test Stakes (200mm, 8mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_DET3_Earth_Tester_Spec.pdf?1684\" target=\"_blank\" title=\"Megger DET3TC\" rel=\"noopener noreferrer\"\u003eMegger DET3 Series Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-07-29T09:48:49-06:00","created_at":"2019-07-29T09:56:30-06:00","vendor":"Megger","type":"Earth Ground Testers","tags":[],"price":152000,"price_min":152000,"price_max":185000,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16821896085547,"title":"MEG-DET3TC","option1":"MEG-DET3TC","option2":null,"option3":null,"sku":"MEG-DET3TC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET3 Series 3-Terminal Digital Ground Tester - MEG-DET3TC","public_title":"MEG-DET3TC","options":["MEG-DET3TC"],"price":185000,"weight":1361,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16822297100331,"title":"MEG-DET3TD","option1":"MEG-DET3TD","option2":null,"option3":null,"sku":"MEG-DET3TD","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET3 Series 3-Terminal Digital Ground Tester - MEG-DET3TD","public_title":"MEG-DET3TD","options":["MEG-DET3TD"],"price":152000,"weight":1361,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-det3tc.jpg?v=1564415798"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-det3tc.jpg?v=1564415798","options":["Model"],"media":[{"alt":null,"id":2811027292203,"position":1,"preview_image":{"aspect_ratio":1.0,"height":700,"width":700,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-det3tc.jpg?v=1564415798"},"aspect_ratio":1.0,"height":700,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-det3tc.jpg?v=1564415798","width":700}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe DET3TD is for basic ground testing while the DET3TC includes a current measuring function for ART (Attached Rod Technique) testing capabilities. With this added function, on-site grounds can be tested separately without having to remove the utility connection (as explained further in this document).\u003c\/p\u003e\n\u003cp\u003eBy using the optional ICLAMP with the DET3TC, the user can augment the traditional fall-of-potential measurement method with ART (Attached Rod Technique), which allows electrode testing without disconnection and also leakage current measurements down to 0.5 mA.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIP54 rated\u003c\/li\u003e\n\u003cli\u003e2 and 3 point testing\u003c\/li\u003e\n\u003cli\u003eSelectable 25 V or 50 V output\u003c\/li\u003e\n\u003cli\u003eComplete with lead and stake kit\u003c\/li\u003e\n\u003cli\u003eSimple one button operation\u003c\/li\u003e\n\u003cli\u003eHard carry case\u003c\/li\u003e\n\u003cli\u003eDelivered with calibration certificate\u003c\/li\u003e\n\u003cli\u003eAttached Rod Technique (ART)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"920\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDET3TC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDET3TD\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP54\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP54\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eC Spike Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eP Spike Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNoise Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNoise Rejection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e40 V pk to pk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e40 V pk to pk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e2-Wire Test\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e3-Wire Test\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNo Disconnect Testing (ART)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes, with optional ICLAMP\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEarth Current Range with ICLAMP\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.5 mA to 19.9 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eResistance Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.01 to 2000Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.01 to 2000Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eResistance Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2% ±3 digits\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2% ±3 digits\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEarth Voltage Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0 - 100 V a.c.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0 - 100 V a.c.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEarth Voltage Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2% ±2 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2% ±2 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLCD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLCD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8 off AA cells\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8 off AA cells\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-15 to +55ºC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-15 to +55ºC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40 to +70ºC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40 to +70ºC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEN61010-1 CAT IV 100 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEN61010-1 CAT IV 100 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e203 x 148 x 78 mm (8 x 5.7 x 3.2 inches)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e203 x 148 x 78 mm (8 x 5.7 x 3.2 inches)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e3-Terminal Digital Ground Tester\u003c\/li\u003e\n\u003cli\u003eHard Carry Case\u003c\/li\u003e\n\u003cli\u003eReplacement 3-Wire Lead Set (15m Red Wire, 10m Yellow Wire, 4m Green Wire)\u003c\/li\u003e\n\u003cli\u003e2 x Ground Test Stakes (200mm, 8mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_DET3_Earth_Tester_Spec.pdf?1684\" target=\"_blank\" title=\"Megger DET3TC\" rel=\"noopener noreferrer\"\u003eMegger DET3 Series Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger DET3 Series 3-Terminal Digital Ground Tester

Megger DET3 Series 3-Terminal Digital Ground Tester

$1,520.00 CAD

The DET3TD is for basic ground testing while the DET3TC includes a current measuring function for ART (Attached Rod Technique) testing capabilities. With this added function, on-site grounds can be tested separately without having to remove the utility connection (as explained further in this document). By using the optional ICLAMP with the DET3...


More Info
Megger DET4 Series Earth Ground Testers

Earth Ground Testers

From $2,415.00 CAD
{"id":1840875864107,"title":"Megger DET4 Series Earth Ground Testers","handle":"megger-det4-series","description":"\u003cp\u003eMegger’s popular 4-terminal ground testing instrument family includes four basic models with different kit variants for each that include select accessories for greater testing flexibility.\u003c\/p\u003e\n\u003cp\u003eThe four basic units are: Model Description DET4TD2 Dry-cell battery powered basic 4-terminal tester DET4TR2 Rechargeable battery powered basic 4-terminal tester DET4TC2 Dry-cell battery powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity and attached rod technique and stakeless measurement capability DET4TCR2 Rechargeable battery powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity and attached rod technique and stakeless measurement capability\u003c\/p\u003e\n\u003cp\u003eThe top-end models (DET4TC2 and DET4TCR2) include a current measuring function for ART (Attached Rod Technique) testing capabilities. With this added function, on-site grounds can be tested separately without having to remove the utility connection (as explained further in this document). They also provide stakeless testing capability. This method allows the operator to use the instrument like a clamp-on ground tester in applications where that method is viable, while also being able to operate as a fall of potential tester if required.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eStakeless testing capability, which allows the operator to use the instrument like a clamp-on tester in applications where the method is viable\u003c\/li\u003e\n\u003cli\u003eAttached Rod Technique capability, which allows fall of potential testing without the need to disconnect the ground rod\u003c\/li\u003e\n\u003cli\u003eMultiple, user selectable test frequencies allow the operator to find the most effective frequency for making the measurement\u003c\/li\u003e\n\u003cli\u003e200,000 Ω measurement range provides the ability to measure the resistivity of any type of soil\u003c\/li\u003e\n\u003cli\u003eUser selectable test voltage ensures that the units can be used in agricultural environments\u003c\/li\u003e\n\u003cli\u003eMicroprocessor control for improved error detection\u003c\/li\u003e\n\u003cli\u003eClear, unambiguous warnings and error indications ensure the reliability of the reading and reduce test time\u003c\/li\u003e\n\u003cli\u003eRugged, weatherproof case to IP54 makes the units truly outdoor instruments\u003c\/li\u003e\n\u003cli\u003eBacklit LCD allows for testing in dark environments\u003c\/li\u003e\n\u003cli\u003eNoise rejection to 40 V pk to pk allows accurate testing in noisy environments\u003c\/li\u003e\n\u003cli\u003eTesting kits and certificates supplied — everything needed to start testing immediately\u003c\/li\u003e\n\u003cli\u003eAccuracy of 2% of reading enhances reliability of measurements\u003c\/li\u003e\n\u003cli\u003eVoltmeter function included allows you to measure the ground voltage and enhances operator safety\u003c\/li\u003e\n\u003cli\u003eCAT IV 100V provides increased operator safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"721\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"133\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eSelection Guide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"280\"\u003eModel #\u003c\/td\u003e\n\u003ctd width=\"77\"\u003eDET4TD2\u003c\/td\u003e\n\u003ctd width=\"77\"\u003eDET4TR2\u003c\/td\u003e\n\u003ctd width=\"77\"\u003eDET4TC2\u003c\/td\u003e\n\u003ctd width=\"77\"\u003eDET4TCR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"9\"\u003e\u003cspan\u003e\u003cstrong\u003eTests\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2-Pole Measurement\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3-Pole Measurement\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-Pole Measurement\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoil Resistivity\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eART Capability\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStakeless Measurement Capability\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e0.01 to 20,000 Ω \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e0.01 to 200,000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Voltage Range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003e0 to 100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Current Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e0.5 mA to 19.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable Voltage (25\/50 V)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Frequency\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e128 Hz\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e94, 105, 111, 128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlkaline Batteries\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRechargeable Batteries\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise Rejection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 V Peak-to-Peak\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT IV 100V\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRated to IP54\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHard Carry Case\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTest Leads (49 ft, 33 ft, 33 ft, 10 ft) and Spikes\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHard Carrying Case\u003c\/li\u003e\n\u003cli\u003e4 x Test Leads (49ft, 33ft, 33ft, 10ft)\u003c\/li\u003e\n\u003cli\u003eSet of Spikes\u003c\/li\u003e\n\u003cli\u003e8 x AA Alkaline Batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_DET4_Series_Spec.pdf?1684\" target=\"_blank\" title=\"Megger DET4 Series Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger DET4 Series Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-07-26T08:50:28-06:00","created_at":"2019-07-26T09:10:56-06:00","vendor":"Megger","type":"Earth Ground Testers","tags":[],"price":241500,"price_min":241500,"price_max":541500,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16808744517675,"title":"MEG-DET4TD2","option1":"MEG-DET4TD2","option2":null,"option3":null,"sku":"MEG-DET4TD2","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET4 Series Earth Ground Testers - MEG-DET4TD2","public_title":"MEG-DET4TD2","options":["MEG-DET4TD2"],"price":241500,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16808744550443,"title":"MEG-DET4TR2","option1":"MEG-DET4TR2","option2":null,"option3":null,"sku":"MEG-DET4TR2","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET4 Series Earth Ground Testers - MEG-DET4TR2","public_title":"MEG-DET4TR2","options":["MEG-DET4TR2"],"price":298000,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16808744583211,"title":"MEG-DET4TC2","option1":"MEG-DET4TC2","option2":null,"option3":null,"sku":"MEG-DET4TC2","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET4 Series Earth Ground Testers - MEG-DET4TC2","public_title":"MEG-DET4TC2","options":["MEG-DET4TC2"],"price":306000,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16808744648747,"title":"MEG-DET4TCR2","option1":"MEG-DET4TCR2","option2":null,"option3":null,"sku":"MEG-DET4TCR2","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET4 Series Earth Ground Testers - MEG-DET4TCR2","public_title":"MEG-DET4TCR2","options":["MEG-DET4TCR2"],"price":339500,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16808744681515,"title":"MEG-DET4TC2+CLAMPS","option1":"MEG-DET4TC2+CLAMPS","option2":null,"option3":null,"sku":"MEG-DET4TC2+CLAMPS","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET4 Series Earth Ground Testers - MEG-DET4TC2+CLAMPS","public_title":"MEG-DET4TC2+CLAMPS","options":["MEG-DET4TC2+CLAMPS"],"price":482000,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16808744714283,"title":"MEG-DET4TCR2+CLAMPS","option1":"MEG-DET4TCR2+CLAMPS","option2":null,"option3":null,"sku":"MEG-DET4TCR2+CLAMPS","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET4 Series Earth Ground Testers - MEG-DET4TCR2+CLAMPS","public_title":"MEG-DET4TCR2+CLAMPS","options":["MEG-DET4TCR2+CLAMPS"],"price":541500,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16808744747051,"title":"MEG-DET4TCR2+KIT","option1":"MEG-DET4TCR2+KIT","option2":null,"option3":null,"sku":"MEG-DET4TCR2+KIT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET4 Series Earth Ground Testers - MEG-DET4TCR2+KIT","public_title":"MEG-DET4TCR2+KIT","options":["MEG-DET4TCR2+KIT"],"price":404500,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/det4td.jpg?v=1564153860"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/det4td.jpg?v=1564153860","options":["Model"],"media":[{"alt":null,"id":2807515840555,"position":1,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/det4td.jpg?v=1564153860"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/det4td.jpg?v=1564153860","width":500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eMegger’s popular 4-terminal ground testing instrument family includes four basic models with different kit variants for each that include select accessories for greater testing flexibility.\u003c\/p\u003e\n\u003cp\u003eThe four basic units are: Model Description DET4TD2 Dry-cell battery powered basic 4-terminal tester DET4TR2 Rechargeable battery powered basic 4-terminal tester DET4TC2 Dry-cell battery powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity and attached rod technique and stakeless measurement capability DET4TCR2 Rechargeable battery powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity and attached rod technique and stakeless measurement capability\u003c\/p\u003e\n\u003cp\u003eThe top-end models (DET4TC2 and DET4TCR2) include a current measuring function for ART (Attached Rod Technique) testing capabilities. With this added function, on-site grounds can be tested separately without having to remove the utility connection (as explained further in this document). They also provide stakeless testing capability. This method allows the operator to use the instrument like a clamp-on ground tester in applications where that method is viable, while also being able to operate as a fall of potential tester if required.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eStakeless testing capability, which allows the operator to use the instrument like a clamp-on tester in applications where the method is viable\u003c\/li\u003e\n\u003cli\u003eAttached Rod Technique capability, which allows fall of potential testing without the need to disconnect the ground rod\u003c\/li\u003e\n\u003cli\u003eMultiple, user selectable test frequencies allow the operator to find the most effective frequency for making the measurement\u003c\/li\u003e\n\u003cli\u003e200,000 Ω measurement range provides the ability to measure the resistivity of any type of soil\u003c\/li\u003e\n\u003cli\u003eUser selectable test voltage ensures that the units can be used in agricultural environments\u003c\/li\u003e\n\u003cli\u003eMicroprocessor control for improved error detection\u003c\/li\u003e\n\u003cli\u003eClear, unambiguous warnings and error indications ensure the reliability of the reading and reduce test time\u003c\/li\u003e\n\u003cli\u003eRugged, weatherproof case to IP54 makes the units truly outdoor instruments\u003c\/li\u003e\n\u003cli\u003eBacklit LCD allows for testing in dark environments\u003c\/li\u003e\n\u003cli\u003eNoise rejection to 40 V pk to pk allows accurate testing in noisy environments\u003c\/li\u003e\n\u003cli\u003eTesting kits and certificates supplied — everything needed to start testing immediately\u003c\/li\u003e\n\u003cli\u003eAccuracy of 2% of reading enhances reliability of measurements\u003c\/li\u003e\n\u003cli\u003eVoltmeter function included allows you to measure the ground voltage and enhances operator safety\u003c\/li\u003e\n\u003cli\u003eCAT IV 100V provides increased operator safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"721\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"133\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eSelection Guide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"280\"\u003eModel #\u003c\/td\u003e\n\u003ctd width=\"77\"\u003eDET4TD2\u003c\/td\u003e\n\u003ctd width=\"77\"\u003eDET4TR2\u003c\/td\u003e\n\u003ctd width=\"77\"\u003eDET4TC2\u003c\/td\u003e\n\u003ctd width=\"77\"\u003eDET4TCR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"9\"\u003e\u003cspan\u003e\u003cstrong\u003eTests\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2-Pole Measurement\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3-Pole Measurement\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-Pole Measurement\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoil Resistivity\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eART Capability\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStakeless Measurement Capability\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e0.01 to 20,000 Ω \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e0.01 to 200,000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Voltage Range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003e0 to 100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Current Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e0.5 mA to 19.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable Voltage (25\/50 V)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Frequency\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e128 Hz\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e94, 105, 111, 128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlkaline Batteries\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRechargeable Batteries\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise Rejection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 V Peak-to-Peak\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT IV 100V\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRated to IP54\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHard Carry Case\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTest Leads (49 ft, 33 ft, 33 ft, 10 ft) and Spikes\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHard Carrying Case\u003c\/li\u003e\n\u003cli\u003e4 x Test Leads (49ft, 33ft, 33ft, 10ft)\u003c\/li\u003e\n\u003cli\u003eSet of Spikes\u003c\/li\u003e\n\u003cli\u003e8 x AA Alkaline Batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_DET4_Series_Spec.pdf?1684\" target=\"_blank\" title=\"Megger DET4 Series Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger DET4 Series Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger DET4 Series Earth Ground Testers

Megger DET4 Series Earth Ground Testers

$4,045.00 CAD

Megger’s popular 4-terminal ground testing instrument family includes four basic models with different kit variants for each that include select accessories for greater testing flexibility. The four basic units are: Model Description DET4TD2 Dry-cell battery powered basic 4-terminal tester DET4TR2 Rechargeable battery powered basic 4-terminal te...


More Info
Megger Digital Earth Clamps

Earth Ground Testers

From $2,250.00 CAD
{"id":1839645392939,"title":"Megger Digital Earth Clamps","handle":"megger-digital-earth-clamps","description":"\u003cdiv style=\"padding-left: 30px;\"\u003eThe DET14C and DET24C represent a new generation of earth\/\u003c\/div\u003e\n\u003cdiv\u003eground clamp-on resistance testers. These instruments induce a\u003c\/div\u003e\n\u003cdiv\u003etest current into earth systems and measure ground resistance\u003c\/div\u003e\n\u003cdiv\u003ein multi ground installations without needing to disconnect the\u003c\/div\u003e\n\u003cdiv\u003eground. They offer market leading access, advanced features, simple\u003c\/div\u003e\n\u003cdiv\u003eoperation and CAT IV 600 V safety protection.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 30px;\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 30px;\"\u003eThe DET14C offers storage of results for later on-screen recall and\u003c\/div\u003e\n\u003cdiv\u003ethe DET24C supports a download of results via Bluetooth® into\u003c\/div\u003e\n\u003cdiv\u003ePowerDB and PowerDB Lite, Megger’s acceptance and maintenance\u003c\/div\u003e\n\u003cdiv\u003etest data management software.\u003c\/div\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eDesigned with flat core ends they prevent dirt build up, ensuring\u003cbr\u003emeasurement integrity and improved reliability over products with\u003cbr\u003einterlocking teeth. Other enhancements over current generation\u003cbr\u003eproducts include improved accuracy and up to 300% increase\u003cbr\u003ein battery life. In electrically noisy environments the built-in filter\u003cbr\u003efunction offers increased noise immunity.\u003cbr\u003e\u003cbr\u003eDET14C and DET24C also offer a true RMS AC current\u003cbr\u003emeasurement facility up to 35 Amps. The instrument’s ability to\u003cbr\u003emeasure current flowing in an earth cable is a useful safety feature,\u003cbr\u003eespecially if the earth cable has to be disconnected. A high current\u003cbr\u003eflow to earth could draw an arc on dis-connection with potentially\u003cbr\u003esevere consequences.\u003cbr\u003e\u003cbr\u003eThe elliptical shaped head design offers improved access to cables\u003cbr\u003eand earth straps in space constrained locations. The clamp head\u003cbr\u003eaccommodates up to 37 mm diameter cable and 50 mm earth tapes\u003cbr\u003emaking them suitable for use in power stations, substations, towers\u003cbr\u003eand many more facilities. Operation in dark and restricted areas is\u003cbr\u003efacilitated by a display with backlight and an audible tone associated\u003cbr\u003ewith the hold key. Optimized jaw opening mechanism ensures proper\u003cbr\u003ejaw closure without excessive use of force when opening the jaws.\u003c\/p\u003e\n\u003cstrong\u003eLarge elliptical clamp (head) design\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAllows testing of round cables\/rods up to 37 mm diameter and ground tapes\/straps up to 50 mm width\u003c\/li\u003e\n\u003cli\u003eImproved testing access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eSmooth mating surfaces on the clamp head\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEasy to clean\u003c\/li\u003e\n\u003cli\u003eNo interlocking teeth to damage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCATIV 600 V operation\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eHighest level of user safety available\u003c\/li\u003e\n\u003cli\u003eUnit can be used safely before the distribution board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eNoise filter function\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUser can select the filter function to increase noise immunity\u003c\/li\u003e\n\u003cli\u003eAllows the unit to be used in higher electrical noise environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eResistance and current limit alarm functions (visual and audible)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMinimum and maximum limits can be set to reduce test time\/improve accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eIntelligent data hold function (preset before testing)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIncreases instrument ease of use in difficult testing locations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eBacklit display\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAllows for operation in low light environments such as cable basements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eTime and date stamped results\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eImproved data\/results management\u003c\/li\u003e\n\u003cli\u003eImproved accuracy of result reporting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eNew ergonomic trigger design\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEasier and more comfortable to operate\u003c\/li\u003e\n\u003cli\u003eLess chance of slippage causing the head to snap shut\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eUltra long battery life (24 hours continuous) with readily available batteries\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eLonger operating time\u003c\/li\u003e\n\u003cli\u003eReduced cost of ownership\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eResistance Measurements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003eGround Resistance Range\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eResolution\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eIntrinsic Certainty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e0.05 Ω to 0.99 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.01 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±1.5% ±0.05 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e1.00 Ω to 9.99 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.01 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±1.5% ± 0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e10.0 Ω to 99.9 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.1 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±2% ± 0.5 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e100.0 Ω to 199.9 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.1 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±5% ± 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e200 Ω to 400 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±6% ± 5 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e400 Ω to 600 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±10% ± 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e600 Ω to 1200 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e1200 Ω to 1500 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±35%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eFrequency of measurement 1390 Hz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCarrying case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCarrying strap (wrist loop) \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUser guide CD-ROM\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCalibration check \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBattery AA (Alkaline) (4 required) \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_DET14C-DET24C_Spec.pdf?1682\" target=\"_blank\" title=\"Megger DET14C and DET24C Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger DET14C and DET24C Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-07-25T11:11:32-06:00","created_at":"2019-07-25T11:18:06-06:00","vendor":"Megger","type":"Earth Ground Testers","tags":[],"price":225000,"price_min":225000,"price_max":266500,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16804230856747,"title":"MEG-DET14C","option1":"MEG-DET14C","option2":null,"option3":null,"sku":"MEG-DET14C","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger Digital Earth Clamps - MEG-DET14C","public_title":"MEG-DET14C","options":["MEG-DET14C"],"price":266500,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16804230922283,"title":"MEG-DET24C","option1":"MEG-DET24C","option2":null,"option3":null,"sku":"MEG-DET24C","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger Digital Earth Clamps - MEG-DET24C","public_title":"MEG-DET24C","options":["MEG-DET24C"],"price":225000,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_DET14C.jpg?v=1564075089"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_DET14C.jpg?v=1564075089","options":["Model"],"media":[{"alt":null,"id":2806236348459,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_DET14C.jpg?v=1564075089"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_DET14C.jpg?v=1564075089","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv style=\"padding-left: 30px;\"\u003eThe DET14C and DET24C represent a new generation of earth\/\u003c\/div\u003e\n\u003cdiv\u003eground clamp-on resistance testers. These instruments induce a\u003c\/div\u003e\n\u003cdiv\u003etest current into earth systems and measure ground resistance\u003c\/div\u003e\n\u003cdiv\u003ein multi ground installations without needing to disconnect the\u003c\/div\u003e\n\u003cdiv\u003eground. They offer market leading access, advanced features, simple\u003c\/div\u003e\n\u003cdiv\u003eoperation and CAT IV 600 V safety protection.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 30px;\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 30px;\"\u003eThe DET14C offers storage of results for later on-screen recall and\u003c\/div\u003e\n\u003cdiv\u003ethe DET24C supports a download of results via Bluetooth® into\u003c\/div\u003e\n\u003cdiv\u003ePowerDB and PowerDB Lite, Megger’s acceptance and maintenance\u003c\/div\u003e\n\u003cdiv\u003etest data management software.\u003c\/div\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eDesigned with flat core ends they prevent dirt build up, ensuring\u003cbr\u003emeasurement integrity and improved reliability over products with\u003cbr\u003einterlocking teeth. Other enhancements over current generation\u003cbr\u003eproducts include improved accuracy and up to 300% increase\u003cbr\u003ein battery life. In electrically noisy environments the built-in filter\u003cbr\u003efunction offers increased noise immunity.\u003cbr\u003e\u003cbr\u003eDET14C and DET24C also offer a true RMS AC current\u003cbr\u003emeasurement facility up to 35 Amps. The instrument’s ability to\u003cbr\u003emeasure current flowing in an earth cable is a useful safety feature,\u003cbr\u003eespecially if the earth cable has to be disconnected. A high current\u003cbr\u003eflow to earth could draw an arc on dis-connection with potentially\u003cbr\u003esevere consequences.\u003cbr\u003e\u003cbr\u003eThe elliptical shaped head design offers improved access to cables\u003cbr\u003eand earth straps in space constrained locations. The clamp head\u003cbr\u003eaccommodates up to 37 mm diameter cable and 50 mm earth tapes\u003cbr\u003emaking them suitable for use in power stations, substations, towers\u003cbr\u003eand many more facilities. Operation in dark and restricted areas is\u003cbr\u003efacilitated by a display with backlight and an audible tone associated\u003cbr\u003ewith the hold key. Optimized jaw opening mechanism ensures proper\u003cbr\u003ejaw closure without excessive use of force when opening the jaws.\u003c\/p\u003e\n\u003cstrong\u003eLarge elliptical clamp (head) design\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAllows testing of round cables\/rods up to 37 mm diameter and ground tapes\/straps up to 50 mm width\u003c\/li\u003e\n\u003cli\u003eImproved testing access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eSmooth mating surfaces on the clamp head\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEasy to clean\u003c\/li\u003e\n\u003cli\u003eNo interlocking teeth to damage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCATIV 600 V operation\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eHighest level of user safety available\u003c\/li\u003e\n\u003cli\u003eUnit can be used safely before the distribution board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eNoise filter function\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUser can select the filter function to increase noise immunity\u003c\/li\u003e\n\u003cli\u003eAllows the unit to be used in higher electrical noise environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eResistance and current limit alarm functions (visual and audible)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMinimum and maximum limits can be set to reduce test time\/improve accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eIntelligent data hold function (preset before testing)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIncreases instrument ease of use in difficult testing locations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eBacklit display\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAllows for operation in low light environments such as cable basements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eTime and date stamped results\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eImproved data\/results management\u003c\/li\u003e\n\u003cli\u003eImproved accuracy of result reporting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eNew ergonomic trigger design\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEasier and more comfortable to operate\u003c\/li\u003e\n\u003cli\u003eLess chance of slippage causing the head to snap shut\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eUltra long battery life (24 hours continuous) with readily available batteries\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eLonger operating time\u003c\/li\u003e\n\u003cli\u003eReduced cost of ownership\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eResistance Measurements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003eGround Resistance Range\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eResolution\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eIntrinsic Certainty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e0.05 Ω to 0.99 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.01 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±1.5% ±0.05 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e1.00 Ω to 9.99 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.01 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±1.5% ± 0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e10.0 Ω to 99.9 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.1 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±2% ± 0.5 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e100.0 Ω to 199.9 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.1 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±5% ± 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e200 Ω to 400 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±6% ± 5 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e400 Ω to 600 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±10% ± 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e600 Ω to 1200 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e1200 Ω to 1500 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±35%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eFrequency of measurement 1390 Hz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCarrying case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCarrying strap (wrist loop) \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUser guide CD-ROM\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCalibration check \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBattery AA (Alkaline) (4 required) \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_DET14C-DET24C_Spec.pdf?1682\" target=\"_blank\" title=\"Megger DET14C and DET24C Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger DET14C and DET24C Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger Digital Earth Clamps

Megger Digital Earth Clamps

$2,250.00 CAD

The DET14C and DET24C represent a new generation of earth/ ground clamp-on resistance testers. These instruments induce a test current into earth systems and measure ground resistance in multi ground installations without needing to disconnect the ground. They offer market leading access, advanced features, simple operation and CAT IV 600 V safe...


More Info
Megger DLRO10 10A Low Resistance Ohmmeter

Microohmmeters / DLROs

$5,125.00 CAD
{"id":1839507898411,"title":"Megger DLRO10 10A Low Resistance Ohmmeter","handle":"megger-dlro10-10a-low-resistance-ohmmeter","description":"\u003cp\u003eThe MEGGER DUCTER DLRO10 and DUCTER DLRO10X bring new standards to low resistance measurement. Both are fully automatic instruments, selecting the most suitable test current, up to 10 A dc to measure resistance from 0.1 µΩ to 2000 Ω on one of seven ranges. For users who desire more control over the measurement process, DLRO 10X uses a menu system controlled by a two-axis paddle to allow manual selection of the test current. DLRO10X also adds real-time download of results and on-board storage for later download to a PC.\u003c\/p\u003e\n\u003cp\u003eBoth instruments are built into a strong, lightweight case that is equally at home in the field or in the laboratory. Light enough to be worn around the neck, they are small enough to be taken into areas which were previously too small to access. DLRO 10 uses a large, bright 4-1\/2-digit LED display while DLRO 10X has a large, backlit LCD display.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAuto current reversal cancels standing emfs\u003c\/li\u003e\n\u003cli\u003eProtected to 600 V\u003c\/li\u003e\n\u003cli\u003eAutomatically detects continuity in potential and current connections\u003c\/li\u003e\n\u003cli\u003eMultiple operating modes including fully automatic\u003c\/li\u003e\n\u003cli\u003eAlpha-numeric keypad for entering test notes (DLRO 10X)\u003c\/li\u003e\n\u003cli\u003eUser selectable high and low limits (DLRO 10X)\u003c\/li\u003e\n\u003cli\u003ePrinter output and memory (DLRO 10X)\u003c\/li\u003e\n\u003cli\u003eSmall, lightweight and portable - can be used in tight places, reduces the need for extra long leads and two person operation.\u003c\/li\u003e\n\u003cli\u003eFour terminal resistance method shows the true resistance of the item under test.\u003c\/li\u003e\n\u003cli\u003eBright LED (DLRO 10) and LCD (DLRO 10X) displays are easily visible under all lighting conditions and reduce human error.\u003c\/li\u003e\n\u003cli\u003eAutomatically applies forward and reverse currents which cancel out any standing voltages across the sample under test.\u003c\/li\u003e\n\u003cli\u003eChecks for undue noise during measurement, reducing the possibility of recording the incorrect result.\u003c\/li\u003e\n\u003cli\u003eAutomatically detects continuity in P and C circuits, preventing erroneously high reading to be taken due to high resistance contact.\u003c\/li\u003e\n\u003cli\u003eBattery module has a battery condition indicator allowing the user to check the state of spare batteries without connecting to the instrument.\u003c\/li\u003e\n\u003cli\u003eRS232 connector on the DLRO 10X allows downloading of results in real time or stored for later retrieval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003e0 - 1.999 M-ohm 0 - 19.99 M-ohm 0 - 199.9 M-ohm 0 - 1.9999 ohm 0 - 19.99 ohm 0 - 199.99 ohm 0 - 1999.9 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µ-ohm 1 µ-ohm 10 µ-ohm 100 µ-ohm 1 M-ohm 10 M-ohm 100 M-ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e100 A 10 A 1 A 100 mA 10 mA 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 lsd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eRechargeable batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220mm (H) x 100mm (W) x 237mm (D) (8.4 x 4 x 9.5 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 kg (5 3\/4 lb) approximately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eDLRO10 10A Micro-ohmmeter\/Data Logger\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e7 Ah NiMH battery module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDH4 Duplex handspikes (2), one with indicator lights. 1.2m \/ 4 ft \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eBattery charger for operation from 115\/230 V, 50\/60Hz supply\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCigar lighter adapter for battery charging\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUser guide\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWarranty card\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/DLRO10_DLRO10X_specs.pdf?1651\" target=\"_blank\" title=\"Megger DLRO10 Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger DLRO10 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-07-25T09:12:02-06:00","created_at":"2019-07-25T09:16:05-06:00","vendor":"Megger","type":"Microohmmeters \/ DLROs","tags":[],"price":512500,"price_min":512500,"price_max":512500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16803826073643,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-DLRO-10","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DLRO10 10A Low Resistance Ohmmeter","public_title":null,"options":["Default Title"],"price":512500,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-dlro10_54e55ca2-e229-4f55-81b5-da03b0a87193.jpg?v=1564067767"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-dlro10_54e55ca2-e229-4f55-81b5-da03b0a87193.jpg?v=1564067767","options":["Title"],"media":[{"alt":null,"id":2806121496619,"position":1,"preview_image":{"aspect_ratio":1.0,"height":700,"width":700,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-dlro10_54e55ca2-e229-4f55-81b5-da03b0a87193.jpg?v=1564067767"},"aspect_ratio":1.0,"height":700,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-dlro10_54e55ca2-e229-4f55-81b5-da03b0a87193.jpg?v=1564067767","width":700}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe MEGGER DUCTER DLRO10 and DUCTER DLRO10X bring new standards to low resistance measurement. Both are fully automatic instruments, selecting the most suitable test current, up to 10 A dc to measure resistance from 0.1 µΩ to 2000 Ω on one of seven ranges. For users who desire more control over the measurement process, DLRO 10X uses a menu system controlled by a two-axis paddle to allow manual selection of the test current. DLRO10X also adds real-time download of results and on-board storage for later download to a PC.\u003c\/p\u003e\n\u003cp\u003eBoth instruments are built into a strong, lightweight case that is equally at home in the field or in the laboratory. Light enough to be worn around the neck, they are small enough to be taken into areas which were previously too small to access. DLRO 10 uses a large, bright 4-1\/2-digit LED display while DLRO 10X has a large, backlit LCD display.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAuto current reversal cancels standing emfs\u003c\/li\u003e\n\u003cli\u003eProtected to 600 V\u003c\/li\u003e\n\u003cli\u003eAutomatically detects continuity in potential and current connections\u003c\/li\u003e\n\u003cli\u003eMultiple operating modes including fully automatic\u003c\/li\u003e\n\u003cli\u003eAlpha-numeric keypad for entering test notes (DLRO 10X)\u003c\/li\u003e\n\u003cli\u003eUser selectable high and low limits (DLRO 10X)\u003c\/li\u003e\n\u003cli\u003ePrinter output and memory (DLRO 10X)\u003c\/li\u003e\n\u003cli\u003eSmall, lightweight and portable - can be used in tight places, reduces the need for extra long leads and two person operation.\u003c\/li\u003e\n\u003cli\u003eFour terminal resistance method shows the true resistance of the item under test.\u003c\/li\u003e\n\u003cli\u003eBright LED (DLRO 10) and LCD (DLRO 10X) displays are easily visible under all lighting conditions and reduce human error.\u003c\/li\u003e\n\u003cli\u003eAutomatically applies forward and reverse currents which cancel out any standing voltages across the sample under test.\u003c\/li\u003e\n\u003cli\u003eChecks for undue noise during measurement, reducing the possibility of recording the incorrect result.\u003c\/li\u003e\n\u003cli\u003eAutomatically detects continuity in P and C circuits, preventing erroneously high reading to be taken due to high resistance contact.\u003c\/li\u003e\n\u003cli\u003eBattery module has a battery condition indicator allowing the user to check the state of spare batteries without connecting to the instrument.\u003c\/li\u003e\n\u003cli\u003eRS232 connector on the DLRO 10X allows downloading of results in real time or stored for later retrieval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003e0 - 1.999 M-ohm 0 - 19.99 M-ohm 0 - 199.9 M-ohm 0 - 1.9999 ohm 0 - 19.99 ohm 0 - 199.99 ohm 0 - 1999.9 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µ-ohm 1 µ-ohm 10 µ-ohm 100 µ-ohm 1 M-ohm 10 M-ohm 100 M-ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e100 A 10 A 1 A 100 mA 10 mA 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 lsd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eRechargeable batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220mm (H) x 100mm (W) x 237mm (D) (8.4 x 4 x 9.5 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 kg (5 3\/4 lb) approximately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eDLRO10 10A Micro-ohmmeter\/Data Logger\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e7 Ah NiMH battery module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDH4 Duplex handspikes (2), one with indicator lights. 1.2m \/ 4 ft \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eBattery charger for operation from 115\/230 V, 50\/60Hz supply\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCigar lighter adapter for battery charging\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUser guide\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWarranty card\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/DLRO10_DLRO10X_specs.pdf?1651\" target=\"_blank\" title=\"Megger DLRO10 Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger DLRO10 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger DLRO10 10A Low Resistance Ohmmeter

Megger DLRO10 10A Low Resistance Ohmmeter

$5,125.00 CAD

The MEGGER DUCTER DLRO10 and DUCTER DLRO10X bring new standards to low resistance measurement. Both are fully automatic instruments, selecting the most suitable test current, up to 10 A dc to measure resistance from 0.1 µΩ to 2000 Ω on one of seven ranges. For users who desire more control over the measurement process, DLRO 10X uses a menu syste...


More Info
Megger DLRO10HD 10A Low Resistance Ohmmeter

Microohmmeters / DLROs

$5,520.00 CAD
{"id":1839519203371,"title":"Megger DLRO10HD 10A Low Resistance Ohmmeter","handle":"megger-dlro10hd-10a-low-resistance-ohmmeter","description":"\u003cp\u003e\u003cspan\u003eEqually at home in the laboratory, the workshop or in the field, on the bench or on the ground, Megger’s new heavy duty DLRO10HD low resistance ohmmeter combines rugged construction with accuracy and ease of use. It features an internal rechargeable battery and can also operate from a mains supply, even if the battery is completely flat.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh or low output power selection for condition diagnosis\u003c\/li\u003e\n\u003cli\u003eRechargeable battery or line power supply, continuous operation, even with dead battery\u003c\/li\u003e\n\u003cli\u003e10 A for 60 seconds, less time waiting to cool, great for charging inductance\u003c\/li\u003e\n\u003cli\u003eHigh input protection to 600 V, inadvertent connection to line or UPS voltage will not blow a fuse\u003c\/li\u003e\n\u003cli\u003eHeavy duty case: IP65 lid closed, IP54 operational (battery operation only)\u003c\/li\u003e\n\u003cli\u003eRotary switch selects one of five test modes, including auto start on connection, giving ease of use\u003c\/li\u003e\n\u003cli\u003eRugged case well suited for transportation and includes a lead set pouch\u003c\/li\u003e\n\u003cli\u003eRemovable lid facilitates easy test lead connection\u003c\/li\u003e\n\u003cli\u003eOperational ingress protection is IP54 (battery power only) ensuring protection from the elements\u003c\/li\u003e\n\u003cli\u003e7Ah lead acid battery provides extended operation and can be charged whilst operating from line power\u003c\/li\u003e\n\u003cli\u003eRotary mode switch with bidirectional (current reversal with averaging cancels thermal EMFs), unidirectional, automatic, continuous and inductive modes\u003c\/li\u003e\n\u003cli\u003eLarge, clear LCD display with backlight and contrast adjustment\u003c\/li\u003e\n\u003cli\u003eAuto power off function conserves battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe DLRO10HD features two ranges with extended compliance. Effectively there are two 2.5 Ω and two 250 mΩ ranges one low power, and one high power. The chart below shows the power output curves for the two 250 mΩ ranges. Each range provided 10 µΩ resolution allowing the user to make comparative measurements at either 0.25 Ω or 25 Ω maximum outputs.\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"521\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e \u003cbr\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDLRO10\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDLRO10HD\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower Limited Ouput Test Ranges (\u0026lt;0.25 W)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHigh Power Output Test Ranges (25W)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAuto Current Reversal\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAuto Start (Continuity Detection)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHigh Input Protection \u0026lt; 600V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise Limit Exceeded Indicator\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eUser Interchangeable Detachable Battery\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHang from neck operation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperate From Mains\/Line Supply\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIP65 Lid Closed\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIP54 in Use\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eUltra Tough Case\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDLRO10HD Digital Low Resistance Ohmmeter\u003c\/li\u003e\n\u003cli\u003eDH4-C Duplex Hand Spikes (Including One with Indicator Lights), 4 ft. (1.2 m)\u003c\/li\u003e\n\u003cli\u003eTest Lead Pouch, Lid-Mounted\u003c\/li\u003e\n\u003cli\u003eUser Guide CD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_DLRO10HD.pdf?1680\" target=\"_blank\" title=\"Megger DLRO10HD\" rel=\"noopener noreferrer\"\u003eMegger DLRO10HD\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-07-25T09:24:41-06:00","created_at":"2019-07-25T09:29:41-06:00","vendor":"Megger","type":"Microohmmeters \/ DLROs","tags":[],"price":552000,"price_min":552000,"price_max":552000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16803859988523,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-DLRO-10HD","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DLRO10HD 10A Low Resistance Ohmmeter","public_title":null,"options":["Default Title"],"price":552000,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_DLRO10HD_Pic.jpg?v=1564071436"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_DLRO10HD_Pic.jpg?v=1564071436","options":["Title"],"media":[{"alt":null,"id":2806176645163,"position":1,"preview_image":{"aspect_ratio":0.77,"height":1707,"width":1315,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_DLRO10HD_Pic.jpg?v=1564071436"},"aspect_ratio":0.77,"height":1707,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_DLRO10HD_Pic.jpg?v=1564071436","width":1315}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eEqually at home in the laboratory, the workshop or in the field, on the bench or on the ground, Megger’s new heavy duty DLRO10HD low resistance ohmmeter combines rugged construction with accuracy and ease of use. It features an internal rechargeable battery and can also operate from a mains supply, even if the battery is completely flat.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh or low output power selection for condition diagnosis\u003c\/li\u003e\n\u003cli\u003eRechargeable battery or line power supply, continuous operation, even with dead battery\u003c\/li\u003e\n\u003cli\u003e10 A for 60 seconds, less time waiting to cool, great for charging inductance\u003c\/li\u003e\n\u003cli\u003eHigh input protection to 600 V, inadvertent connection to line or UPS voltage will not blow a fuse\u003c\/li\u003e\n\u003cli\u003eHeavy duty case: IP65 lid closed, IP54 operational (battery operation only)\u003c\/li\u003e\n\u003cli\u003eRotary switch selects one of five test modes, including auto start on connection, giving ease of use\u003c\/li\u003e\n\u003cli\u003eRugged case well suited for transportation and includes a lead set pouch\u003c\/li\u003e\n\u003cli\u003eRemovable lid facilitates easy test lead connection\u003c\/li\u003e\n\u003cli\u003eOperational ingress protection is IP54 (battery power only) ensuring protection from the elements\u003c\/li\u003e\n\u003cli\u003e7Ah lead acid battery provides extended operation and can be charged whilst operating from line power\u003c\/li\u003e\n\u003cli\u003eRotary mode switch with bidirectional (current reversal with averaging cancels thermal EMFs), unidirectional, automatic, continuous and inductive modes\u003c\/li\u003e\n\u003cli\u003eLarge, clear LCD display with backlight and contrast adjustment\u003c\/li\u003e\n\u003cli\u003eAuto power off function conserves battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe DLRO10HD features two ranges with extended compliance. Effectively there are two 2.5 Ω and two 250 mΩ ranges one low power, and one high power. The chart below shows the power output curves for the two 250 mΩ ranges. Each range provided 10 µΩ resolution allowing the user to make comparative measurements at either 0.25 Ω or 25 Ω maximum outputs.\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"521\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e \u003cbr\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDLRO10\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDLRO10HD\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower Limited Ouput Test Ranges (\u0026lt;0.25 W)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHigh Power Output Test Ranges (25W)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAuto Current Reversal\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAuto Start (Continuity Detection)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHigh Input Protection \u0026lt; 600V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eNoise Limit Exceeded Indicator\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eUser Interchangeable Detachable Battery\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHang from neck operation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperate From Mains\/Line Supply\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIP65 Lid Closed\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIP54 in Use\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eUltra Tough Case\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eX\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDLRO10HD Digital Low Resistance Ohmmeter\u003c\/li\u003e\n\u003cli\u003eDH4-C Duplex Hand Spikes (Including One with Indicator Lights), 4 ft. (1.2 m)\u003c\/li\u003e\n\u003cli\u003eTest Lead Pouch, Lid-Mounted\u003c\/li\u003e\n\u003cli\u003eUser Guide CD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_DLRO10HD.pdf?1680\" target=\"_blank\" title=\"Megger DLRO10HD\" rel=\"noopener noreferrer\"\u003eMegger DLRO10HD\u003c\/a\u003e\u003c\/p\u003e"}
Megger DLRO10HD 10A Low Resistance Ohmmeter

Megger DLRO10HD 10A Low Resistance Ohmmeter

$5,520.00 CAD

Equally at home in the laboratory, the workshop or in the field, on the bench or on the ground, Megger’s new heavy duty DLRO10HD low resistance ohmmeter combines rugged construction with accuracy and ease of use. It features an internal rechargeable battery and can also operate from a mains supply, even if the battery is completely flat. Overvi...


More Info
Megger DLRO10X Digital Low Resistance Ohm Meter

Microohmmeters / DLROs

$6,155.00 CAD
{"id":1262847229995,"title":"Megger DLRO10X Digital Low Resistance Ohm Meter","handle":"megger-dlro10x-digital-low-resistance-ohm-meter","description":"\u003cp\u003eThe MEGGER DUCTER™ DLRO10X bring new standards to low resistance measurement. It is a fully automatic instrument, selecting the most suitable test current, up to 10 A dc to measure resistance from 0.1 µΩ to 2000 Ω on one of seven ranges. For users who desire more control over the measurement process, DLRO 10X uses a menu system controlled by a two-axis paddle to allow manual selection of the test current. DLRO10X also adds real-time download of results and on-board storage for later download to a PC.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAccurate results in under three seconds\u003c\/li\u003e\n\u003cli\u003eAuto current reversal cancels standing emfs\u003c\/li\u003e\n\u003cli\u003eFuse protected to 600 V\u003c\/li\u003e\n\u003cli\u003eNiMH battery reduces weight\u003c\/li\u003e\n\u003cli\u003e250 mW power limit (with optional override) to avoid heating the test sample\u003c\/li\u003e\n\u003cli\u003eAutomatically detects continuity in potential and current connections\u003c\/li\u003e\n\u003cli\u003eVisible warning of high voltages present at the terminals\u003c\/li\u003e\n\u003cli\u003eVisible warning of current flowing in the test sample\u003c\/li\u003e\n\u003cli\u003eMultiple operating modes including fully automatic\u003c\/li\u003e\n\u003cli\u003eAlpha-numeric keypad for entering test notes\u003c\/li\u003e\n\u003cli\u003eUser setable high and low limits\u003c\/li\u003e\n\u003cli\u003eAutoranging with Manual option\u003c\/li\u003e\n\u003cli\u003ePrinter output and memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003e0 - 1.999 M-ohm 0 - 19.99 M-ohm 0 - 199.9 M-ohm 0 - 1.9999 ohm 0 - 19.99 ohm 0 - 199.99 ohm 0 - 1999.9 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µ-ohm 1 µ-ohm 10 µ-ohm 100 µ-ohm 1 M-ohm 10 M-ohm 100 M-ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e100 A 10 A 1 A 100 mA 10 mA 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 lsd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eRechargeable batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220mm (H) x 100mm (W) x 237mm (D) (8.4 x 4 x 9.5 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 kg (5 3\/4 lb) approximately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eDLRO10X 10A Micro-ohmmeter\/Data Logger\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e7 Ah NiMH battery module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eBattery charger for operation from 115\/230 V, 50\/60Hz supply\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCigar lighter adapter for battery charging\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUser guide\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWarranty card\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/DLRO10_DLRO10X_specs.pdf?1588\" target=\"_blank\" title=\"Megger DLRO10X Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger DLRO10X Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-05-16T12:47:46-06:00","created_at":"2018-05-16T12:48:10-06:00","vendor":"Megger","type":"Microohmmeters \/ DLROs","tags":["Electrical"],"price":615500,"price_min":615500,"price_max":615500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12140519129131,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-DLRO-10X","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DLRO10X Digital Low Resistance Ohm Meter","public_title":null,"options":["Default Title"],"price":615500,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger-DLRO10.jpg?v=1526496754"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger-DLRO10.jpg?v=1526496754","options":["Title"],"media":[{"alt":null,"id":1663439470635,"position":1,"preview_image":{"aspect_ratio":0.714,"height":1206,"width":861,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger-DLRO10.jpg?v=1526496754"},"aspect_ratio":0.714,"height":1206,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger-DLRO10.jpg?v=1526496754","width":861}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe MEGGER DUCTER™ DLRO10X bring new standards to low resistance measurement. It is a fully automatic instrument, selecting the most suitable test current, up to 10 A dc to measure resistance from 0.1 µΩ to 2000 Ω on one of seven ranges. For users who desire more control over the measurement process, DLRO 10X uses a menu system controlled by a two-axis paddle to allow manual selection of the test current. DLRO10X also adds real-time download of results and on-board storage for later download to a PC.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAccurate results in under three seconds\u003c\/li\u003e\n\u003cli\u003eAuto current reversal cancels standing emfs\u003c\/li\u003e\n\u003cli\u003eFuse protected to 600 V\u003c\/li\u003e\n\u003cli\u003eNiMH battery reduces weight\u003c\/li\u003e\n\u003cli\u003e250 mW power limit (with optional override) to avoid heating the test sample\u003c\/li\u003e\n\u003cli\u003eAutomatically detects continuity in potential and current connections\u003c\/li\u003e\n\u003cli\u003eVisible warning of high voltages present at the terminals\u003c\/li\u003e\n\u003cli\u003eVisible warning of current flowing in the test sample\u003c\/li\u003e\n\u003cli\u003eMultiple operating modes including fully automatic\u003c\/li\u003e\n\u003cli\u003eAlpha-numeric keypad for entering test notes\u003c\/li\u003e\n\u003cli\u003eUser setable high and low limits\u003c\/li\u003e\n\u003cli\u003eAutoranging with Manual option\u003c\/li\u003e\n\u003cli\u003ePrinter output and memory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003e0 - 1.999 M-ohm 0 - 19.99 M-ohm 0 - 199.9 M-ohm 0 - 1.9999 ohm 0 - 19.99 ohm 0 - 199.99 ohm 0 - 1999.9 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µ-ohm 1 µ-ohm 10 µ-ohm 100 µ-ohm 1 M-ohm 10 M-ohm 100 M-ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e100 A 10 A 1 A 100 mA 10 mA 1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 lsd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eRechargeable batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220mm (H) x 100mm (W) x 237mm (D) (8.4 x 4 x 9.5 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 kg (5 3\/4 lb) approximately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eDLRO10X 10A Micro-ohmmeter\/Data Logger\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e7 Ah NiMH battery module\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003eBattery charger for operation from 115\/230 V, 50\/60Hz supply\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCigar lighter adapter for battery charging\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUser guide\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWarranty card\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/DLRO10_DLRO10X_specs.pdf?1588\" target=\"_blank\" title=\"Megger DLRO10X Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger DLRO10X Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger DLRO10X Digital Low Resistance Ohm Meter

Megger DLRO10X Digital Low Resistance Ohm Meter

$6,155.00 CAD

The MEGGER DUCTER™ DLRO10X bring new standards to low resistance measurement. It is a fully automatic instrument, selecting the most suitable test current, up to 10 A dc to measure resistance from 0.1 µΩ to 2000 Ω on one of seven ranges. For users who desire more control over the measurement process, DLRO 10X uses a menu system controlled by a t...


More Info
Megger DLRO200 Digital Low Resistance Ohm Meter

Microohmmeters / DLROs

$10,260.00 CAD
{"id":1281433305131,"title":"Megger DLRO200 Digital Low Resistance Ohm Meter","handle":"megger-dlro200-digital-low-resistance-ohm-meter","description":"\u003cp\u003eMegger DLRO200 measures resistances between 0.1 µΩ and 1 Ω, at high currents.\u003c\/p\u003e\n\u003cp\u003eThis versatile instrument can provide test currents from 10 amps up to 200 amps subject to the load resistance and supply voltage. A large LCD displays all all test parameters and measurement results.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSmall and weighs less than 15 kg (33 lbs)\u003c\/li\u003e\n\u003cli\u003eTest currents from 10 A to 200 A DC\u003c\/li\u003e\n\u003cli\u003e0.1 µΩ best resolution\u003c\/li\u003e\n\u003cli\u003eOn board memory for up to 300 test results and notes\u003c\/li\u003e\n\u003cli\u003eRS232 port to download stored results or for real time output to a printer\u003c\/li\u003e\n\u003cli\u003eSupplied complete with 5m (16.4 ft.) test leads and download software\u003c\/li\u003e\n\u003cli\u003eSmooth, continuous applied current eliminates magnetic transients capable of inductively tripping breaker controls (115 V version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.1 µΩ to 999.9 mΩ (Subject to supply voltage and leads used)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e±0.5% ± 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e±0.5% ± 0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eBetter than 1% from 300µΩ to 100mΩ\u003cbr\u003eBetter than ±2% from 100µΩ to 300µΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Modes:\u003c\/td\u003e\n\u003ctd\u003eManual, Auto, Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e10 A to 200 A DC *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2% ±2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter input impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;200 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHum rejection\u003c\/td\u003e\n\u003ctd\u003e5 V rms 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eDLRO200-EN 200 Amp Digital Micrometer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e5 m (16.4 ft.) Lead set set comprising 2 x 50 mm2 current leads with clips and 2 potential leads with clips\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDownload Manager \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUser Guide on CD-ROM \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRS232 download cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eQuick Start Guide\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWarranty card\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/DLRO200_DS_en.pdf?1589\" target=\"_blank\" title=\"Megger DLRO200 Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger DLRO200 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-05-25T09:32:18-06:00","created_at":"2018-05-25T09:40:14-06:00","vendor":"Megger","type":"Microohmmeters \/ DLROs","tags":["Electrical"],"price":1026000,"price_min":1026000,"price_max":1026000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12260382408747,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-DLRO200-EN","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DLRO200 Digital Low Resistance Ohm Meter","public_title":null,"options":["Default Title"],"price":1026000,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/dlro200_en_image_12.jpg?v=1527262816"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/dlro200_en_image_12.jpg?v=1527262816","options":["Title"],"media":[{"alt":null,"id":1679484452907,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/dlro200_en_image_12.jpg?v=1527262816"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/dlro200_en_image_12.jpg?v=1527262816","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eMegger DLRO200 measures resistances between 0.1 µΩ and 1 Ω, at high currents.\u003c\/p\u003e\n\u003cp\u003eThis versatile instrument can provide test currents from 10 amps up to 200 amps subject to the load resistance and supply voltage. A large LCD displays all all test parameters and measurement results.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSmall and weighs less than 15 kg (33 lbs)\u003c\/li\u003e\n\u003cli\u003eTest currents from 10 A to 200 A DC\u003c\/li\u003e\n\u003cli\u003e0.1 µΩ best resolution\u003c\/li\u003e\n\u003cli\u003eOn board memory for up to 300 test results and notes\u003c\/li\u003e\n\u003cli\u003eRS232 port to download stored results or for real time output to a printer\u003c\/li\u003e\n\u003cli\u003eSupplied complete with 5m (16.4 ft.) test leads and download software\u003c\/li\u003e\n\u003cli\u003eSmooth, continuous applied current eliminates magnetic transients capable of inductively tripping breaker controls (115 V version)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.1 µΩ to 999.9 mΩ (Subject to supply voltage and leads used)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e±0.5% ± 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent\u003c\/td\u003e\n\u003ctd\u003e±0.5% ± 0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003eBetter than 1% from 300µΩ to 100mΩ\u003cbr\u003eBetter than ±2% from 100µΩ to 300µΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Modes:\u003c\/td\u003e\n\u003ctd\u003eManual, Auto, Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e10 A to 200 A DC *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2% ±2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter input impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;200 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHum rejection\u003c\/td\u003e\n\u003ctd\u003e5 V rms 50 Hz\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eDLRO200-EN 200 Amp Digital Micrometer\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e5 m (16.4 ft.) Lead set set comprising 2 x 50 mm2 current leads with clips and 2 potential leads with clips\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDownload Manager \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUser Guide on CD-ROM \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRS232 download cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eQuick Start Guide\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eWarranty card\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/DLRO200_DS_en.pdf?1589\" target=\"_blank\" title=\"Megger DLRO200 Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger DLRO200 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger DLRO200 Digital Low Resistance Ohm Meter

Megger DLRO200 Digital Low Resistance Ohm Meter

$10,260.00 CAD

Megger DLRO200 measures resistances between 0.1 µΩ and 1 Ω, at high currents. This versatile instrument can provide test currents from 10 amps up to 200 amps subject to the load resistance and supply voltage. A large LCD displays all all test parameters and measurement results. Overview Small and weighs less than 15 kg (33 lbs) Test currents f...


More Info
Megger MIT1015 10kV Essential Insulation Tester

Insulation Testers

$8,350.00 CAD
{"id":8561277862078,"title":"Megger MIT1015 10kV Essential Insulation Tester","handle":"megger-mit1015-10kv-essential-insulation-tester","description":"\u003cp\u003e\u003cspan\u003eThe Megger range of insulation testers are known worldwide for their rugged dependability, long service life, and accurate, reliable measurements. These instruments provide an excellent level of noise immunity, test performance, and safety. The Essential models are perfect for performing 'go\/no go' testing, no need to record test results, working in tough locations, using up to 10 kV test voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRE\u0026gt;Act mode not only measures reabsorption current but also provides an indication to the user of the impact it will have on measurement range and accuracy\u003c\/li\u003e\n\u003cli\u003eRE\u0026gt;Act removes the possibility to pass insulation that should have been failed, and it can also be used to monitor discharge following a test\u003c\/li\u003e\n\u003cli\u003ePreconfigured diagnostic tests include:\n\u003cul\u003e\n\u003cli\u003ePolarisation Index (PI)\u003c\/li\u003e\n\u003cli\u003eDielectric Absorption Ratio (DAR)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePI predictor function (PIp) uses the first part of the IR curve to predict the rest at 5 minutes into the test\u003c\/li\u003e\n\u003cli\u003ePreset voltage ranges are provided in insulation test mode\u003c\/li\u003e\n\u003cli\u003eMeasures up to 10 TΩ\u003c\/li\u003e\n\u003cli\u003eUp to 3 mA noise rejection\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical contractors\u003c\/li\u003e\n\u003cli\u003eTesting and service companies\u003c\/li\u003e\n\u003cli\u003eWind farm and solar generation operators\u003c\/li\u003e\n\u003cli\u003ePower generation and distribution companies\u003c\/li\u003e\n\u003cli\u003eIndustrial companies\u003c\/li\u003e\n\u003cli\u003eRail companies\u003c\/li\u003e\n\u003cli\u003eAcceptance testing at installation to check conformance to specifications\u003c\/li\u003e\n\u003cli\u003eRoutine preventive\/predictive maintenance testing after installation\u003c\/li\u003e\n\u003cli\u003eQA testing as part of the manufacturing process\u003c\/li\u003e\n\u003cli\u003eDiagnostic testing to isolate faulty components for repair\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e500 V, 1000 V, 2500 V, 5000 V, 10,000 V, or User-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e+4%, -0%, ±10 V nominal at 1 GΩ load 32 to 86°F (0 to 30°C )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 15 TΩ at 5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5%: 2 TΩ at 10,000 V, 1 TΩ at 5000 V, 500 GΩ at 2500 V, 200 GΩ at 1000 V, 100 GΩ at 500 V\u003cbr\u003e±20%: 20 TΩ at 10,000 V, 10 TΩ at 5000 V, 5 TΩ at 2500 V, 2 TΩ at 1000 V, 1 TΩ at 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd\u003e10 nF to 25 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10% ±5 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e0.01 nA to 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% ±0.2 nA at all voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference Rejection\u003c\/td\u003e\n\u003ctd\u003e3 mA from 450 V to 5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Range\u003c\/td\u003e\n\u003ctd\u003e30 V to 660 V AC\/DC, 45 Hz to 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3%, ±3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuard Terminal Performance\u003c\/td\u003e\n\u003ctd\u003eGuards out current IG ≥5000× IL at 100 GΩ \/ 5000 V with maximum error of 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue Display Range\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Display Range\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 20 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit \/ Charge Current\u003c\/td\u003e\n\u003ctd\u003e3 mA at 5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Alarm\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Charge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5 s\/μF at 3 mA to 10 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Discharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;250 ms\/μF to discharge from 10 kV to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Ranging AC Voltage\u003c\/td\u003e\n\u003ctd\u003e90 to 264 V rms\u003cbr\u003e47 to 63 Hz\u003cbr\u003e100 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Charge Time\u003c\/td\u003e\n\u003ctd\u003e2.5 hours (deep discharge)\u003cbr\u003e2 hours (normal discharge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e10.8 V, 5.2 Ah Li-ion\u003cbr\u003eMeets IEC 62133:2003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e4.5 hours (typical) continuous testing at 10 kV with a 100 MΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Range\u003c\/td\u003e\n\u003ctd\u003eUp to 99 minutes 59 seconds (15 seconds minimum setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Modes\u003c\/td\u003e\n\u003ctd\u003eIR, IR(t), DAR, PI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMIT1015 Insulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003ePower lead\u003c\/li\u003e\n\u003cli\u003eLead set HV 9 x 9' (3 x 3 m), with medium and large clips\u003c\/li\u003e\n\u003cli\u003eFused test probe and clip lead set, 1 kV\u003c\/li\u003e\n\u003cli\u003eControl circuit test set\u003c\/li\u003e\n\u003cli\u003eCalibration certificate\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_MIT515-2_MIT1015_Essential_Insulation_Testers_Spec_Sheet_-_2025.pdf?v=1755869831\" title=\"Megger MIT1015 Spec Sheet\" rel=\"noopener\" target=\"_blank\"\u003eMegger MIT1015\/2 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2025-08-22T07:56:20-06:00","created_at":"2025-08-22T07:56:20-06:00","vendor":"Megger","type":"Insulation Testers","tags":[],"price":835000,"price_min":835000,"price_max":835000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":45331626164414,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-MIT1015-US","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger MIT1015 10kV Essential Insulation Tester","public_title":null,"options":["Default Title"],"price":835000,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerMIT1025-2.jpg?v=1755870951"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerMIT1025-2.jpg?v=1755870951","options":["Title"],"media":[{"alt":null,"id":30500942938302,"position":1,"preview_image":{"aspect_ratio":1.0,"height":900,"width":900,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerMIT1025-2.jpg?v=1755870951"},"aspect_ratio":1.0,"height":900,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerMIT1025-2.jpg?v=1755870951","width":900}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Megger range of insulation testers are known worldwide for their rugged dependability, long service life, and accurate, reliable measurements. These instruments provide an excellent level of noise immunity, test performance, and safety. The Essential models are perfect for performing 'go\/no go' testing, no need to record test results, working in tough locations, using up to 10 kV test voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRE\u0026gt;Act mode not only measures reabsorption current but also provides an indication to the user of the impact it will have on measurement range and accuracy\u003c\/li\u003e\n\u003cli\u003eRE\u0026gt;Act removes the possibility to pass insulation that should have been failed, and it can also be used to monitor discharge following a test\u003c\/li\u003e\n\u003cli\u003ePreconfigured diagnostic tests include:\n\u003cul\u003e\n\u003cli\u003ePolarisation Index (PI)\u003c\/li\u003e\n\u003cli\u003eDielectric Absorption Ratio (DAR)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePI predictor function (PIp) uses the first part of the IR curve to predict the rest at 5 minutes into the test\u003c\/li\u003e\n\u003cli\u003ePreset voltage ranges are provided in insulation test mode\u003c\/li\u003e\n\u003cli\u003eMeasures up to 10 TΩ\u003c\/li\u003e\n\u003cli\u003eUp to 3 mA noise rejection\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical contractors\u003c\/li\u003e\n\u003cli\u003eTesting and service companies\u003c\/li\u003e\n\u003cli\u003eWind farm and solar generation operators\u003c\/li\u003e\n\u003cli\u003ePower generation and distribution companies\u003c\/li\u003e\n\u003cli\u003eIndustrial companies\u003c\/li\u003e\n\u003cli\u003eRail companies\u003c\/li\u003e\n\u003cli\u003eAcceptance testing at installation to check conformance to specifications\u003c\/li\u003e\n\u003cli\u003eRoutine preventive\/predictive maintenance testing after installation\u003c\/li\u003e\n\u003cli\u003eQA testing as part of the manufacturing process\u003c\/li\u003e\n\u003cli\u003eDiagnostic testing to isolate faulty components for repair\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e500 V, 1000 V, 2500 V, 5000 V, 10,000 V, or User-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e+4%, -0%, ±10 V nominal at 1 GΩ load 32 to 86°F (0 to 30°C )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 15 TΩ at 5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5%: 2 TΩ at 10,000 V, 1 TΩ at 5000 V, 500 GΩ at 2500 V, 200 GΩ at 1000 V, 100 GΩ at 500 V\u003cbr\u003e±20%: 20 TΩ at 10,000 V, 10 TΩ at 5000 V, 5 TΩ at 2500 V, 2 TΩ at 1000 V, 1 TΩ at 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd\u003e10 nF to 25 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10% ±5 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e0.01 nA to 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% ±0.2 nA at all voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference Rejection\u003c\/td\u003e\n\u003ctd\u003e3 mA from 450 V to 5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Range\u003c\/td\u003e\n\u003ctd\u003e30 V to 660 V AC\/DC, 45 Hz to 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3%, ±3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuard Terminal Performance\u003c\/td\u003e\n\u003ctd\u003eGuards out current IG ≥5000× IL at 100 GΩ \/ 5000 V with maximum error of 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue Display Range\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Display Range\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 20 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit \/ Charge Current\u003c\/td\u003e\n\u003ctd\u003e3 mA at 5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Alarm\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Charge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5 s\/μF at 3 mA to 10 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Discharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;250 ms\/μF to discharge from 10 kV to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Ranging AC Voltage\u003c\/td\u003e\n\u003ctd\u003e90 to 264 V rms\u003cbr\u003e47 to 63 Hz\u003cbr\u003e100 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Charge Time\u003c\/td\u003e\n\u003ctd\u003e2.5 hours (deep discharge)\u003cbr\u003e2 hours (normal discharge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e10.8 V, 5.2 Ah Li-ion\u003cbr\u003eMeets IEC 62133:2003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e4.5 hours (typical) continuous testing at 10 kV with a 100 MΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Range\u003c\/td\u003e\n\u003ctd\u003eUp to 99 minutes 59 seconds (15 seconds minimum setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Modes\u003c\/td\u003e\n\u003ctd\u003eIR, IR(t), DAR, PI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMIT1015 Insulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003ePower lead\u003c\/li\u003e\n\u003cli\u003eLead set HV 9 x 9' (3 x 3 m), with medium and large clips\u003c\/li\u003e\n\u003cli\u003eFused test probe and clip lead set, 1 kV\u003c\/li\u003e\n\u003cli\u003eControl circuit test set\u003c\/li\u003e\n\u003cli\u003eCalibration certificate\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_MIT515-2_MIT1015_Essential_Insulation_Testers_Spec_Sheet_-_2025.pdf?v=1755869831\" title=\"Megger MIT1015 Spec Sheet\" rel=\"noopener\" target=\"_blank\"\u003eMegger MIT1015\/2 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger MIT1015 10kV Essential Insulation Tester

Megger MIT1015 10kV Essential Insulation Tester

$8,350.00 CAD

The Megger range of insulation testers are known worldwide for their rugged dependability, long service life, and accurate, reliable measurements. These instruments provide an excellent level of noise immunity, test performance, and safety. The Essential models are perfect for performing 'go/no go' testing, no need to record test results, workin...


More Info
Megger MIT1025 10kV Insulation Tester

Insulation Testers

$8,850.00 CAD
{"id":1262797520939,"title":"Megger MIT1025 10kV Insulation Tester","handle":"megger-mit1025-10kv-insulation-tester","description":"\u003cp\u003e\u003cstrong\u003e*SEE NEW MEGGER MIT1025\/2 AND MIT1015 MODELS*\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MIT1025 is compact, light 10 kV insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store.\u003c\/p\u003e\n\u003cp\u003eAs well as measuring insulation resistance to 20 TΩ, the MIT1025 also offers various diagnostic tests such as Polarization index, Dielectric Absorption Ratio, Step Voltage, Dielectric discharge and ramp testing.\u003c\/p\u003e\n\u003cp\u003eNow equipped with lithium ion fast rechargeable batteries, the instrument has a large, clear, easy to read, display making it equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly removing the need for separate timer.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustry best guard terminal accuracy\u003c\/li\u003e\n\u003cli\u003eSmaller size and lightweight allows easier transport and use without compromising performance\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight for easy transport and use\u003c\/li\u003e\n\u003cli\u003eAuto IR, DAR, PI, Step Voltage, DD and Ramp\u003c\/li\u003e\n\u003cli\u003eUnique dual case design provides additional user protection\u003c\/li\u003e\n\u003cli\u003eLithium-ion battery - extended capacity rapid charge\u003c\/li\u003e\n\u003cli\u003eAdvanced memory with time\/date stamp\u003c\/li\u003e\n\u003cli\u003eCATIV 600V safety rating on all terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical contractors\u003c\/li\u003e\n\u003cli\u003eTesting and service companies\u003c\/li\u003e\n\u003cli\u003eWind farm and solar generation operators\u003c\/li\u003e\n\u003cli\u003ePower generation and distribution companies\u003c\/li\u003e\n\u003cli\u003eIndustrial companies\u003c\/li\u003e\n\u003cli\u003eRail companies\u003c\/li\u003e\n\u003cli\u003eAcceptance testing at installation to check conformance to specifications\u003c\/li\u003e\n\u003cli\u003eRoutine preventive\/predictive maintenance testing after installation\u003c\/li\u003e\n\u003cli\u003eQA testing as part of the manufacturing process\u003c\/li\u003e\n\u003cli\u003eDiagnostic testing to isolate faulty components for repair\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Range, Analog\u003c\/td\u003e\n\u003ctd\u003e100kW to 10TW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Range, Digital\u003c\/td\u003e\n\u003ctd\u003e10kW to 20TW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e500V, 1000V, 2500V, 5000V, and 10,000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Defined Test Voltages\u003c\/td\u003e\n\u003ctd\u003e100V to 1kV in 10V steps\u003cbr\u003e1kV to 5kV in 25V steps\u003cbr\u003e5kV to 10kV in 25V steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±5% to 2TΩ, ±20% to 20TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Accuracy\u003c\/td\u003e\n\u003ctd\u003e+4% -0% ±10V of nominal test voltage at 1GW load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Range\u003c\/td\u003e\n\u003ctd\u003e30 to 660V AC\/DC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3% ±3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e45 to 65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current\u003c\/td\u003e\n\u003ctd\u003e3mA nominal, max. power on all loads outperforming many 5mA testers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Alarm\u003c\/td\u003e\n\u003ctd\u003e100kΩ to 1GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e0.01nA to 6mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% ±0.2 nA at all voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range (above 500V)\u003c\/td\u003e\n\u003ctd\u003e10nF to 25µF (dependent on measurement voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10% ±5nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Charge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5s per µF at 3mA to 10kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Discharge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;500 ms\/µF to discharge from 10,000V to 50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMIT1025 Megohmmeter\u003c\/li\u003e\n\u003cli\u003ePower lead\u003c\/li\u003e\n\u003cli\u003e3 x 1002-531 Medium insulated clips, 10ft (3m) leadset\u003c\/li\u003e\n\u003cli\u003e3 x 1002-534 Large insulated clips, 10ft (3m) leadset\u003c\/li\u003e\n\u003cli\u003eUser guide CD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca rel=\"noopener noreferrer\" title=\"Megger MIT1025 Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/MIT515_525_1025_specs.pdf?1591\" target=\"_blank\"\u003eMegger MIT1025 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-05-16T12:41:14-06:00","created_at":"2018-05-16T12:41:17-06:00","vendor":"Megger","type":"Insulation Testers","tags":[],"price":885000,"price_min":885000,"price_max":885000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12140446318635,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-MIT1025-US","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger MIT1025 10kV Insulation Tester","public_title":null,"options":["Default Title"],"price":885000,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit1025-f26.jpg?v=1526496155"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit1025-f26.jpg?v=1526496155","options":["Title"],"media":[{"alt":null,"id":1663398969387,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit1025-f26.jpg?v=1526496155"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit1025-f26.jpg?v=1526496155","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cstrong\u003e*SEE NEW MEGGER MIT1025\/2 AND MIT1015 MODELS*\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MIT1025 is compact, light 10 kV insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store.\u003c\/p\u003e\n\u003cp\u003eAs well as measuring insulation resistance to 20 TΩ, the MIT1025 also offers various diagnostic tests such as Polarization index, Dielectric Absorption Ratio, Step Voltage, Dielectric discharge and ramp testing.\u003c\/p\u003e\n\u003cp\u003eNow equipped with lithium ion fast rechargeable batteries, the instrument has a large, clear, easy to read, display making it equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly removing the need for separate timer.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustry best guard terminal accuracy\u003c\/li\u003e\n\u003cli\u003eSmaller size and lightweight allows easier transport and use without compromising performance\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight for easy transport and use\u003c\/li\u003e\n\u003cli\u003eAuto IR, DAR, PI, Step Voltage, DD and Ramp\u003c\/li\u003e\n\u003cli\u003eUnique dual case design provides additional user protection\u003c\/li\u003e\n\u003cli\u003eLithium-ion battery - extended capacity rapid charge\u003c\/li\u003e\n\u003cli\u003eAdvanced memory with time\/date stamp\u003c\/li\u003e\n\u003cli\u003eCATIV 600V safety rating on all terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical contractors\u003c\/li\u003e\n\u003cli\u003eTesting and service companies\u003c\/li\u003e\n\u003cli\u003eWind farm and solar generation operators\u003c\/li\u003e\n\u003cli\u003ePower generation and distribution companies\u003c\/li\u003e\n\u003cli\u003eIndustrial companies\u003c\/li\u003e\n\u003cli\u003eRail companies\u003c\/li\u003e\n\u003cli\u003eAcceptance testing at installation to check conformance to specifications\u003c\/li\u003e\n\u003cli\u003eRoutine preventive\/predictive maintenance testing after installation\u003c\/li\u003e\n\u003cli\u003eQA testing as part of the manufacturing process\u003c\/li\u003e\n\u003cli\u003eDiagnostic testing to isolate faulty components for repair\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Range, Analog\u003c\/td\u003e\n\u003ctd\u003e100kW to 10TW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Range, Digital\u003c\/td\u003e\n\u003ctd\u003e10kW to 20TW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e500V, 1000V, 2500V, 5000V, and 10,000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Defined Test Voltages\u003c\/td\u003e\n\u003ctd\u003e100V to 1kV in 10V steps\u003cbr\u003e1kV to 5kV in 25V steps\u003cbr\u003e5kV to 10kV in 25V steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±5% to 2TΩ, ±20% to 20TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Accuracy\u003c\/td\u003e\n\u003ctd\u003e+4% -0% ±10V of nominal test voltage at 1GW load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Range\u003c\/td\u003e\n\u003ctd\u003e30 to 660V AC\/DC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3% ±3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e45 to 65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current\u003c\/td\u003e\n\u003ctd\u003e3mA nominal, max. power on all loads outperforming many 5mA testers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Alarm\u003c\/td\u003e\n\u003ctd\u003e100kΩ to 1GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e0.01nA to 6mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% ±0.2 nA at all voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range (above 500V)\u003c\/td\u003e\n\u003ctd\u003e10nF to 25µF (dependent on measurement voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10% ±5nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Charge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5s per µF at 3mA to 10kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Discharge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;500 ms\/µF to discharge from 10,000V to 50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMIT1025 Megohmmeter\u003c\/li\u003e\n\u003cli\u003ePower lead\u003c\/li\u003e\n\u003cli\u003e3 x 1002-531 Medium insulated clips, 10ft (3m) leadset\u003c\/li\u003e\n\u003cli\u003e3 x 1002-534 Large insulated clips, 10ft (3m) leadset\u003c\/li\u003e\n\u003cli\u003eUser guide CD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca rel=\"noopener noreferrer\" title=\"Megger MIT1025 Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/MIT515_525_1025_specs.pdf?1591\" target=\"_blank\"\u003eMegger MIT1025 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger MIT1025 10kV Insulation Tester

Megger MIT1025 10kV Insulation Tester

$8,850.00 CAD

*SEE NEW MEGGER MIT1025/2 AND MIT1015 MODELS* The MIT1025 is compact, light 10 kV insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store. As well as measuring insulation resi...


More Info
Megger MIT1025/2 10kV Advanced Insulation Tester

Insulation Testers

$9,785.00 CAD
{"id":8561275699390,"title":"Megger MIT1025\/2 10kV Advanced Insulation Tester","handle":"megger-mit1025-2-10kv-advanced-insulation-tester","description":"\u003cp\u003e\u003cspan\u003eThe Megger range of insulation testers are known worldwide for their rugged dependability, long service life, and accurate, reliable measurements. The Advanced models are an ideal choice if you need to record test results, transfer results to software\/mobile app (via USB or Bluetooth LE), and want the benefits of more diagnostic insulation testing. The Advanced range also adds additional noise immunity for power distribution environments, and the ability to either increase or decrease the output current.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRE\u0026gt;Act mode not only measures reabsorption current but also provides an indication to the user of the impact it will have on measurement range and accuracy\u003c\/li\u003e\n\u003cli\u003eRE\u0026gt;Act removes the possibility to pass insulation that should have been failed, and it can also be used to monitor discharge following a test\u003c\/li\u003e\n\u003cli\u003ePreconfigured diagnostic tests include:\n\u003cul\u003e\n\u003cli\u003ePolarisation Index (PI)\u003c\/li\u003e\n\u003cli\u003eDielectric Absorption Ratio (DAR)\u003c\/li\u003e\n\u003cli\u003eDielectric Discharge (DD)\u003c\/li\u003e\n\u003cli\u003ePolarisation Depolarisation Current (PDC)\u003c\/li\u003e\n\u003cli\u003eStepped Voltage (SV)\u003c\/li\u003e\n\u003cli\u003eRamp test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePI predictor function (PIp) uses the first part of the IR curve to predict the rest at 5 minutes into the test\u003c\/li\u003e\n\u003cli\u003ePreset voltage ranges are provided in insulation test mode\u003c\/li\u003e\n\u003cli\u003eMeasures up to 20 TΩ\u003c\/li\u003e\n\u003cli\u003eUp to 6 mA noise rejection\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical contractors\u003c\/li\u003e\n\u003cli\u003eTesting and service companies\u003c\/li\u003e\n\u003cli\u003eWind farm and solar generation operators\u003c\/li\u003e\n\u003cli\u003ePower generation and distribution companies\u003c\/li\u003e\n\u003cli\u003eIndustrial companies\u003c\/li\u003e\n\u003cli\u003eRail companies\u003c\/li\u003e\n\u003cli\u003eAcceptance testing at installation to check conformance to specifications\u003c\/li\u003e\n\u003cli\u003eRoutine preventive\/predictive maintenance testing after installation\u003c\/li\u003e\n\u003cli\u003eQA testing as part of the manufacturing process\u003c\/li\u003e\n\u003cli\u003eDiagnostic testing to isolate faulty components for repair\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e500 V, 1000 V, 2500 V, 5000 V, 10,000 V, or User-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e+4%, -0%, ±10 V nominal at 1 GΩ load 32 to 86°F (0 to 30°C )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 20 TΩ at 10 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5%: 2 TΩ at 10 kV, 1 TΩ at 5 kV, 500 GΩ at 2500 V, 200 GΩ at 1000 V, 100 GΩ at 500 V\u003cbr\u003e±20%: 20 TΩ at 10 kV, 10 TΩ at 5 kV, 5 TΩ at 2500 V, 2 TΩ at 1000 V, 1 TΩ at 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd\u003e10 nF to 25 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10% ±5 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e0.01 nA to 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% ±0.2 nA at all voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference Rejection\u003c\/td\u003e\n\u003ctd\u003e6 mA from 960 V to 10 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Range\u003c\/td\u003e\n\u003ctd\u003e30 V to 660 V AC\/DC, 45 Hz to 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3%, ±3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuard Terminal Performance\u003c\/td\u003e\n\u003ctd\u003eGuards out current IG ≥5000× IL at 100 GΩ \/ 5000 V with maximum error of 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue Display Range\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Display Range\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 20 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit \/ Charge Current\u003c\/td\u003e\n\u003ctd\u003e1 mA, 3 mA Default, 6 mA at 5 kV, 10 kV, 15 kV (6 mA only from mains supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Alarm\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Charge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5 s\/μF at 3 mA to 10 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Discharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;250 ms\/μF to discharge from 10 kV to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Ranging AC Voltage\u003c\/td\u003e\n\u003ctd\u003e90 to 264 V rms\u003cbr\u003e47 to 63 Hz\u003cbr\u003e100 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Charge Time\u003c\/td\u003e\n\u003ctd\u003e2.5 hours (deep discharge)\u003cbr\u003e2 hours (normal discharge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e10.8 V, 5.2 Ah Li-ion\u003cbr\u003eMeets IEC 62133:2003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e4.5 hours (typical) continuous testing at 10 kV with a 100 MΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Range\u003c\/td\u003e\n\u003ctd\u003eUp to 99 minutes 59 seconds (15 seconds minimum setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Modes\u003c\/td\u003e\n\u003ctd\u003eIR, IR(t), DAR, PI, SV, DD, PDC, Ramp test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e5.5 hours logging at 5 second intervals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eQuick Start label\u003c\/li\u003e\n\u003cli\u003ePower lead\u003c\/li\u003e\n\u003cli\u003eScreened USB cable with filters\u003c\/li\u003e\n\u003cli\u003eLead set 3 kV, 9 x 9' (3 x 3 m) with medium clips\u003c\/li\u003e\n\u003cli\u003eLead set HV, 9 x 9' (3 x 3 m) with medium and large clips\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_MIT525-2_MIT1025-2_MIT1525-2_Advanced_Insulation_Testers_Spec_Sheet_-_2025t.pdf?v=1755870425\" target=\"_blank\" title=\"Megger MIT1025\/2 Spec Sheet\" rel=\"noopener\"\u003eMegger MIT1025\/2 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2025-08-22T07:51:34-06:00","created_at":"2025-08-22T07:51:34-06:00","vendor":"Megger","type":"Insulation Testers","tags":[],"price":978500,"price_min":978500,"price_max":978500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":45331622396094,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-MIT1025\/2-US","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger MIT1025\/2 10kV Advanced Insulation Tester","public_title":null,"options":["Default Title"],"price":978500,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerMIT1025-2.jpg?v=1755870951"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerMIT1025-2.jpg?v=1755870951","options":["Title"],"media":[{"alt":null,"id":30500942938302,"position":1,"preview_image":{"aspect_ratio":1.0,"height":900,"width":900,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerMIT1025-2.jpg?v=1755870951"},"aspect_ratio":1.0,"height":900,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerMIT1025-2.jpg?v=1755870951","width":900}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Megger range of insulation testers are known worldwide for their rugged dependability, long service life, and accurate, reliable measurements. The Advanced models are an ideal choice if you need to record test results, transfer results to software\/mobile app (via USB or Bluetooth LE), and want the benefits of more diagnostic insulation testing. The Advanced range also adds additional noise immunity for power distribution environments, and the ability to either increase or decrease the output current.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRE\u0026gt;Act mode not only measures reabsorption current but also provides an indication to the user of the impact it will have on measurement range and accuracy\u003c\/li\u003e\n\u003cli\u003eRE\u0026gt;Act removes the possibility to pass insulation that should have been failed, and it can also be used to monitor discharge following a test\u003c\/li\u003e\n\u003cli\u003ePreconfigured diagnostic tests include:\n\u003cul\u003e\n\u003cli\u003ePolarisation Index (PI)\u003c\/li\u003e\n\u003cli\u003eDielectric Absorption Ratio (DAR)\u003c\/li\u003e\n\u003cli\u003eDielectric Discharge (DD)\u003c\/li\u003e\n\u003cli\u003ePolarisation Depolarisation Current (PDC)\u003c\/li\u003e\n\u003cli\u003eStepped Voltage (SV)\u003c\/li\u003e\n\u003cli\u003eRamp test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePI predictor function (PIp) uses the first part of the IR curve to predict the rest at 5 minutes into the test\u003c\/li\u003e\n\u003cli\u003ePreset voltage ranges are provided in insulation test mode\u003c\/li\u003e\n\u003cli\u003eMeasures up to 20 TΩ\u003c\/li\u003e\n\u003cli\u003eUp to 6 mA noise rejection\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical contractors\u003c\/li\u003e\n\u003cli\u003eTesting and service companies\u003c\/li\u003e\n\u003cli\u003eWind farm and solar generation operators\u003c\/li\u003e\n\u003cli\u003ePower generation and distribution companies\u003c\/li\u003e\n\u003cli\u003eIndustrial companies\u003c\/li\u003e\n\u003cli\u003eRail companies\u003c\/li\u003e\n\u003cli\u003eAcceptance testing at installation to check conformance to specifications\u003c\/li\u003e\n\u003cli\u003eRoutine preventive\/predictive maintenance testing after installation\u003c\/li\u003e\n\u003cli\u003eQA testing as part of the manufacturing process\u003c\/li\u003e\n\u003cli\u003eDiagnostic testing to isolate faulty components for repair\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e500 V, 1000 V, 2500 V, 5000 V, 10,000 V, or User-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e+4%, -0%, ±10 V nominal at 1 GΩ load 32 to 86°F (0 to 30°C )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 20 TΩ at 10 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5%: 2 TΩ at 10 kV, 1 TΩ at 5 kV, 500 GΩ at 2500 V, 200 GΩ at 1000 V, 100 GΩ at 500 V\u003cbr\u003e±20%: 20 TΩ at 10 kV, 10 TΩ at 5 kV, 5 TΩ at 2500 V, 2 TΩ at 1000 V, 1 TΩ at 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd\u003e10 nF to 25 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10% ±5 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e0.01 nA to 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% ±0.2 nA at all voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference Rejection\u003c\/td\u003e\n\u003ctd\u003e6 mA from 960 V to 10 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Range\u003c\/td\u003e\n\u003ctd\u003e30 V to 660 V AC\/DC, 45 Hz to 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3%, ±3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuard Terminal Performance\u003c\/td\u003e\n\u003ctd\u003eGuards out current IG ≥5000× IL at 100 GΩ \/ 5000 V with maximum error of 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue Display Range\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Display Range\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 20 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit \/ Charge Current\u003c\/td\u003e\n\u003ctd\u003e1 mA, 3 mA Default, 6 mA at 5 kV, 10 kV, 15 kV (6 mA only from mains supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Alarm\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Charge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5 s\/μF at 3 mA to 10 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Discharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;250 ms\/μF to discharge from 10 kV to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Ranging AC Voltage\u003c\/td\u003e\n\u003ctd\u003e90 to 264 V rms\u003cbr\u003e47 to 63 Hz\u003cbr\u003e100 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Charge Time\u003c\/td\u003e\n\u003ctd\u003e2.5 hours (deep discharge)\u003cbr\u003e2 hours (normal discharge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e10.8 V, 5.2 Ah Li-ion\u003cbr\u003eMeets IEC 62133:2003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e4.5 hours (typical) continuous testing at 10 kV with a 100 MΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Range\u003c\/td\u003e\n\u003ctd\u003eUp to 99 minutes 59 seconds (15 seconds minimum setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Modes\u003c\/td\u003e\n\u003ctd\u003eIR, IR(t), DAR, PI, SV, DD, PDC, Ramp test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e5.5 hours logging at 5 second intervals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eQuick Start label\u003c\/li\u003e\n\u003cli\u003ePower lead\u003c\/li\u003e\n\u003cli\u003eScreened USB cable with filters\u003c\/li\u003e\n\u003cli\u003eLead set 3 kV, 9 x 9' (3 x 3 m) with medium clips\u003c\/li\u003e\n\u003cli\u003eLead set HV, 9 x 9' (3 x 3 m) with medium and large clips\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_MIT525-2_MIT1025-2_MIT1525-2_Advanced_Insulation_Testers_Spec_Sheet_-_2025t.pdf?v=1755870425\" target=\"_blank\" title=\"Megger MIT1025\/2 Spec Sheet\" rel=\"noopener\"\u003eMegger MIT1025\/2 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger MIT1025/2 10kV Advanced Insulation Tester

Megger MIT1025/2 10kV Advanced Insulation Tester

$9,785.00 CAD

The Megger range of insulation testers are known worldwide for their rugged dependability, long service life, and accurate, reliable measurements. The Advanced models are an ideal choice if you need to record test results, transfer results to software/mobile app (via USB or Bluetooth LE), and want the benefits of more diagnostic insulation testi...


More Info
{"id":1843636174891,"title":"Megger MIT1525 15kV Insulation Tester","handle":"megger-mit1525-15kv-insulation-tester","description":"\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e*SEE NEW MEGGER MIT1525\/2 MODEL*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMegger’s range of MIT insulation resistance testers are targeted at original equipment manufacturers and industrial companies. The top of the new range MIT1525 performs insulation resistance tests up to 15 kV with a 30 TΩ maximum resistance and an accuracy of ±5 % from 1 MΩ up to 3 TΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSafety rated CATIV 1000 V to 3000 m (15 kV)\u003c\/li\u003e\n\u003cli\u003eRapid charge Li-ion battery\u003c\/li\u003e\n\u003cli\u003ePI, DAR, DD, SV and ramp test\u003c\/li\u003e\n\u003cli\u003eOperate from battery or AC source\u003c\/li\u003e\n\u003cli\u003eAdvanced memory with time\/date stamp\u003c\/li\u003e\n\u003cli\u003e30 TΩ maximum resistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCables\u003c\/li\u003e\n\u003cli\u003eTransformers\u003c\/li\u003e\n\u003cli\u003eMotors\u003c\/li\u003e\n\u003cli\u003eGenerators\u003c\/li\u003e\n\u003cli\u003eCircuit breakers\u003c\/li\u003e\n\u003cli\u003eBushings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output voltage\u003c\/td\u003e\n\u003ctd\u003e15 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resistance\u003c\/td\u003e\n\u003ctd\u003e30 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy from 1 MΩ to\u003c\/td\u003e\n\u003ctd\u003e±5% ≤ 3 TΩ, ±20% to 35 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit output current\u003c\/td\u003e\n\u003ctd\u003e3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. noise rejection\u003c\/td\u003e\n\u003ctd\u003e6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating to max. altitude\u003c\/td\u003e\n\u003ctd\u003eCAT IV 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. altitude\u003c\/td\u003e\n\u003ctd\u003e3000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charge\u003c\/td\u003e\n\u003ctd\u003e2.5 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life single charge\u003c\/td\u003e\n\u003ctd\u003e4.5 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e3m Lead Set x 3 Large 15kV Insulated Clips (1005-023)\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv style=\"display: inline !important;\"\u003ePower lead\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eUSB cable (MIT525, MIT1025, MIT1525)\u003c\/li\u003e\n\u003cli\u003ePowerDB Lite software (MIT525, MIT1025, MIT1525)\u003c\/li\u003e\n\u003cli\u003eProduct information CD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/MIT515--MIT525--MIT1025--MIT1525_DS_en_V03.pdf?1692\" title=\"Megger MIT1525 Insulation Tester\" target=\"_blank\"\u003eMegger MIT1525 Insulation Tester\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-07-30T10:42:20-06:00","created_at":"2019-07-30T10:46:41-06:00","vendor":"Megger","type":"Insulation Testers","tags":[],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16825879789611,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-MIT1525-US","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger MIT1525 15kV Insulation Tester","public_title":null,"options":["Default Title"],"price":0,"weight":6804,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/MIT1525.jpg?v=1564505205","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_MIT1525_Pic_2.jpg?v=1564510319"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/MIT1525.jpg?v=1564505205","options":["Title"],"media":[{"alt":null,"id":2811610431531,"position":1,"preview_image":{"aspect_ratio":1.0,"height":2000,"width":2000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/MIT1525.jpg?v=1564505205"},"aspect_ratio":1.0,"height":2000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/MIT1525.jpg?v=1564505205","width":2000},{"alt":null,"id":2811643658283,"position":2,"preview_image":{"aspect_ratio":1.114,"height":1508,"width":1680,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_MIT1525_Pic_2.jpg?v=1564510319"},"aspect_ratio":1.114,"height":1508,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_MIT1525_Pic_2.jpg?v=1564510319","width":1680}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e*SEE NEW MEGGER MIT1525\/2 MODEL*\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eMegger’s range of MIT insulation resistance testers are targeted at original equipment manufacturers and industrial companies. The top of the new range MIT1525 performs insulation resistance tests up to 15 kV with a 30 TΩ maximum resistance and an accuracy of ±5 % from 1 MΩ up to 3 TΩ\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSafety rated CATIV 1000 V to 3000 m (15 kV)\u003c\/li\u003e\n\u003cli\u003eRapid charge Li-ion battery\u003c\/li\u003e\n\u003cli\u003ePI, DAR, DD, SV and ramp test\u003c\/li\u003e\n\u003cli\u003eOperate from battery or AC source\u003c\/li\u003e\n\u003cli\u003eAdvanced memory with time\/date stamp\u003c\/li\u003e\n\u003cli\u003e30 TΩ maximum resistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCables\u003c\/li\u003e\n\u003cli\u003eTransformers\u003c\/li\u003e\n\u003cli\u003eMotors\u003c\/li\u003e\n\u003cli\u003eGenerators\u003c\/li\u003e\n\u003cli\u003eCircuit breakers\u003c\/li\u003e\n\u003cli\u003eBushings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output voltage\u003c\/td\u003e\n\u003ctd\u003e15 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. resistance\u003c\/td\u003e\n\u003ctd\u003e30 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy from 1 MΩ to\u003c\/td\u003e\n\u003ctd\u003e±5% ≤ 3 TΩ, ±20% to 35 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit output current\u003c\/td\u003e\n\u003ctd\u003e3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. noise rejection\u003c\/td\u003e\n\u003ctd\u003e6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety rating to max. altitude\u003c\/td\u003e\n\u003ctd\u003eCAT IV 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. altitude\u003c\/td\u003e\n\u003ctd\u003e3000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery charge\u003c\/td\u003e\n\u003ctd\u003e2.5 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life single charge\u003c\/td\u003e\n\u003ctd\u003e4.5 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e3m Lead Set x 3 Large 15kV Insulated Clips (1005-023)\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv style=\"display: inline !important;\"\u003ePower lead\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eUSB cable (MIT525, MIT1025, MIT1525)\u003c\/li\u003e\n\u003cli\u003ePowerDB Lite software (MIT525, MIT1025, MIT1525)\u003c\/li\u003e\n\u003cli\u003eProduct information CD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/MIT515--MIT525--MIT1025--MIT1525_DS_en_V03.pdf?1692\" title=\"Megger MIT1525 Insulation Tester\" target=\"_blank\"\u003eMegger MIT1525 Insulation Tester\u003c\/a\u003e\u003c\/p\u003e"}
Megger MIT1525 15kV Insulation Tester

Megger MIT1525 15kV Insulation Tester

Call for pricing

*SEE NEW MEGGER MIT1525/2 MODEL* Megger’s range of MIT insulation resistance testers are targeted at original equipment manufacturers and industrial companies. The top of the new range MIT1525 performs insulation resistance tests up to 15 kV with a 30 TΩ maximum resistance and an accuracy of ±5 % from 1 MΩ up to 3 TΩ Overview Features Safety r...


More Info
Megger MIT1525/2 15kV Advanced Insulation Tester

Insulation Testers

$11,245.00 CAD
{"id":8561280123070,"title":"Megger MIT1525\/2 15kV Advanced Insulation Tester","handle":"megger-mit1525-2-15kv-advanced-insulation-tester","description":"\u003cp\u003e\u003cspan\u003eThe Megger range of insulation testers are known worldwide for their rugged dependability, long service life, and accurate, reliable measurements. The Advanced models are an ideal choice if you need to record test results, transfer results to software\/mobile app (via USB or Bluetooth LE), and want the benefits of more diagnostic insulation testing. The Advanced range also adds additional noise immunity for power distribution environments, and the ability to either increase or decrease the output current.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRE\u0026gt;Act mode not only measures reabsorption current but also provides an indication to the user of the impact it will have on measurement range and accuracy\u003c\/li\u003e\n\u003cli\u003eRE\u0026gt;Act removes the possibility to pass insulation that should have been failed, and it can also be used to monitor discharge following a test\u003c\/li\u003e\n\u003cli\u003ePreconfigured diagnostic tests include:\n\u003cul\u003e\n\u003cli\u003ePolarisation Index (PI)\u003c\/li\u003e\n\u003cli\u003eDielectric Absorption Ratio (DAR)\u003c\/li\u003e\n\u003cli\u003eDielectric Discharge (DD)\u003c\/li\u003e\n\u003cli\u003ePolarisation Depolarisation Current (PDC)\u003c\/li\u003e\n\u003cli\u003eStepped Voltage (SV)\u003c\/li\u003e\n\u003cli\u003eRamp test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePI predictor function (PIp) uses the first part of the IR curve to predict the rest at 5 minutes into the test\u003c\/li\u003e\n\u003cli\u003ePreset voltage ranges are provided in insulation test mode\u003c\/li\u003e\n\u003cli\u003eMeasures up to 30 TΩ\u003c\/li\u003e\n\u003cli\u003eUp to 6 mA noise rejection\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCables\u003c\/li\u003e\n\u003cli\u003eTransformers\u003c\/li\u003e\n\u003cli\u003eMotors\u003c\/li\u003e\n\u003cli\u003eGenerators\u003c\/li\u003e\n\u003cli\u003eCircuit breakers\u003c\/li\u003e\n\u003cli\u003eBushings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e1000 V, 2500 V, 5000 V, 10,000 V, 15,000 V, or User-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e+4%, -0%, ±10 V nominal at 1 GΩ load (0°C to 30°C \/ 32 ºF to 86 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 30 TΩ at 15 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5%: 3 TΩ at 15 kV, 2 TΩ at 10 kV, 1 TΩ at 5 kV, 500 GΩ at 2500 V, 200 GΩ at 1000 V\u003cbr\u003e±20%: 30 TΩ at 15 kV, 20 TΩ at 10 kV, 10 TΩ at 5 kV, 5 TΩ at 2500 V, 2 TΩ at 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd\u003e10 nF to 50 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10% ±5 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e0.01 nA to 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% ±0.2 nA at all voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference Rejection\u003c\/td\u003e\n\u003ctd\u003e6 mA from 2100 V to 15 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Range\u003c\/td\u003e\n\u003ctd\u003e30 V to 660 V AC\/DC, 45 Hz to 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3%, ±3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuard Terminal Performance\u003c\/td\u003e\n\u003ctd\u003eGuards out current IG ≥5000× IL at 100 GΩ \/ 5000 V with maximum error of 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue Display Range\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Display Range\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 30 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit \/ Charge Current\u003c\/td\u003e\n\u003ctd\u003e1 mA, 3 mA Default, 6 mA at 5 kV, 10 kV, 15 kV (6 mA only from mains supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Alarm\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Charge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;7.5 s\/μF at 3 mA to 15 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Discharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3500 ms\/μF to discharge from 15 kV to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Ranging AC Voltage\u003c\/td\u003e\n\u003ctd\u003e90 to 264 V rms\u003cbr\u003e47 to 63 Hz\u003cbr\u003e200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Charge Time\u003c\/td\u003e\n\u003ctd\u003e2.5 hours (deep discharge)\u003cbr\u003e2 hours (normal discharge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e10.8 V, 5.2 Ah Li-ion\u003cbr\u003eMeets IEC 62133:2003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e4.5 hours (typical) continuous testing at 15 kV with a 100 MΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Range\u003c\/td\u003e\n\u003ctd\u003eUp to 99 minutes 59 seconds (15 seconds minimum setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Modes\u003c\/td\u003e\n\u003ctd\u003eIR, IR(t), DAR, PI, SV, DD, PDC, Ramp test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e5.5 hours logging at 5 second intervals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eUSB type B (device) Bluetooth® Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal Time Output\u003c\/td\u003e\n\u003ctd\u003e1 Hz output readings (V, I, R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eQuick Start label\u003c\/li\u003e\n\u003cli\u003ePower lead\u003c\/li\u003e\n\u003cli\u003eScreened USB cable with filters\u003c\/li\u003e\n\u003cli\u003eLead set, 9 x 9' (3 x 3 m) with large 15 kV insulated clips\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"Megger MIT1525\/2 Insulation Tester Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_MIT525-2_MIT1025-2_MIT1525-2_Advanced_Insulation_Testers_Spec_Sheet_-_2025t.pdf?v=1755870425\" target=\"_blank\"\u003eMegger MIT1525\/2 Insulation Tester\u003c\/a\u003e\u003c\/p\u003e","published_at":"2025-08-22T08:00:20-06:00","created_at":"2025-08-22T08:00:20-06:00","vendor":"Megger","type":"Insulation Testers","tags":[],"price":1124500,"price_min":1124500,"price_max":1124500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":45331629899966,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-MIT1525\/2-US","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger MIT1525\/2 15kV Advanced Insulation Tester","public_title":null,"options":["Default Title"],"price":1124500,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerMIT525-2.jpg?v=1755871340"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerMIT525-2.jpg?v=1755871340","options":["Title"],"media":[{"alt":null,"id":30500959518910,"position":1,"preview_image":{"aspect_ratio":1.5,"height":1365,"width":2048,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerMIT525-2.jpg?v=1755871340"},"aspect_ratio":1.5,"height":1365,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/files\/MeggerMIT525-2.jpg?v=1755871340","width":2048}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Megger range of insulation testers are known worldwide for their rugged dependability, long service life, and accurate, reliable measurements. The Advanced models are an ideal choice if you need to record test results, transfer results to software\/mobile app (via USB or Bluetooth LE), and want the benefits of more diagnostic insulation testing. The Advanced range also adds additional noise immunity for power distribution environments, and the ability to either increase or decrease the output current.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRE\u0026gt;Act mode not only measures reabsorption current but also provides an indication to the user of the impact it will have on measurement range and accuracy\u003c\/li\u003e\n\u003cli\u003eRE\u0026gt;Act removes the possibility to pass insulation that should have been failed, and it can also be used to monitor discharge following a test\u003c\/li\u003e\n\u003cli\u003ePreconfigured diagnostic tests include:\n\u003cul\u003e\n\u003cli\u003ePolarisation Index (PI)\u003c\/li\u003e\n\u003cli\u003eDielectric Absorption Ratio (DAR)\u003c\/li\u003e\n\u003cli\u003eDielectric Discharge (DD)\u003c\/li\u003e\n\u003cli\u003ePolarisation Depolarisation Current (PDC)\u003c\/li\u003e\n\u003cli\u003eStepped Voltage (SV)\u003c\/li\u003e\n\u003cli\u003eRamp test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePI predictor function (PIp) uses the first part of the IR curve to predict the rest at 5 minutes into the test\u003c\/li\u003e\n\u003cli\u003ePreset voltage ranges are provided in insulation test mode\u003c\/li\u003e\n\u003cli\u003eMeasures up to 30 TΩ\u003c\/li\u003e\n\u003cli\u003eUp to 6 mA noise rejection\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCables\u003c\/li\u003e\n\u003cli\u003eTransformers\u003c\/li\u003e\n\u003cli\u003eMotors\u003c\/li\u003e\n\u003cli\u003eGenerators\u003c\/li\u003e\n\u003cli\u003eCircuit breakers\u003c\/li\u003e\n\u003cli\u003eBushings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e1000 V, 2500 V, 5000 V, 10,000 V, 15,000 V, or User-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e+4%, -0%, ±10 V nominal at 1 GΩ load (0°C to 30°C \/ 32 ºF to 86 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 30 TΩ at 15 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5%: 3 TΩ at 15 kV, 2 TΩ at 10 kV, 1 TΩ at 5 kV, 500 GΩ at 2500 V, 200 GΩ at 1000 V\u003cbr\u003e±20%: 30 TΩ at 15 kV, 20 TΩ at 10 kV, 10 TΩ at 5 kV, 5 TΩ at 2500 V, 2 TΩ at 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range\u003c\/td\u003e\n\u003ctd\u003e10 nF to 50 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10% ±5 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e0.01 nA to 6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% ±0.2 nA at all voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference Rejection\u003c\/td\u003e\n\u003ctd\u003e6 mA from 2100 V to 15 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Range\u003c\/td\u003e\n\u003ctd\u003e30 V to 660 V AC\/DC, 45 Hz to 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3%, ±3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuard Terminal Performance\u003c\/td\u003e\n\u003ctd\u003eGuards out current IG ≥5000× IL at 100 GΩ \/ 5000 V with maximum error of 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue Display Range\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Display Range\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 30 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit \/ Charge Current\u003c\/td\u003e\n\u003ctd\u003e1 mA, 3 mA Default, 6 mA at 5 kV, 10 kV, 15 kV (6 mA only from mains supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Test Alarm\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Charge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;7.5 s\/μF at 3 mA to 15 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Discharge Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3500 ms\/μF to discharge from 15 kV to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Ranging AC Voltage\u003c\/td\u003e\n\u003ctd\u003e90 to 264 V rms\u003cbr\u003e47 to 63 Hz\u003cbr\u003e200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Charge Time\u003c\/td\u003e\n\u003ctd\u003e2.5 hours (deep discharge)\u003cbr\u003e2 hours (normal discharge)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e10.8 V, 5.2 Ah Li-ion\u003cbr\u003eMeets IEC 62133:2003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e4.5 hours (typical) continuous testing at 15 kV with a 100 MΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Range\u003c\/td\u003e\n\u003ctd\u003eUp to 99 minutes 59 seconds (15 seconds minimum setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Modes\u003c\/td\u003e\n\u003ctd\u003eIR, IR(t), DAR, PI, SV, DD, PDC, Ramp test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e5.5 hours logging at 5 second intervals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eUSB type B (device) Bluetooth® Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal Time Output\u003c\/td\u003e\n\u003ctd\u003e1 Hz output readings (V, I, R)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eQuick Start label\u003c\/li\u003e\n\u003cli\u003ePower lead\u003c\/li\u003e\n\u003cli\u003eScreened USB cable with filters\u003c\/li\u003e\n\u003cli\u003eLead set, 9 x 9' (3 x 3 m) with large 15 kV insulated clips\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"Megger MIT1525\/2 Insulation Tester Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_MIT525-2_MIT1025-2_MIT1525-2_Advanced_Insulation_Testers_Spec_Sheet_-_2025t.pdf?v=1755870425\" target=\"_blank\"\u003eMegger MIT1525\/2 Insulation Tester\u003c\/a\u003e\u003c\/p\u003e"}
Megger MIT1525/2 15kV Advanced Insulation Tester

Megger MIT1525/2 15kV Advanced Insulation Tester

$11,245.00 CAD

The Megger range of insulation testers are known worldwide for their rugged dependability, long service life, and accurate, reliable measurements. The Advanced models are an ideal choice if you need to record test results, transfer results to software/mobile app (via USB or Bluetooth LE), and want the benefits of more diagnostic insulation testi...


More Info
Megger MIT200 Series Insulation Testers

Insulation Testers

From $490.00 CAD
{"id":1839491612715,"title":"Megger MIT200 Series Insulation Testers","handle":"megger-mit200-series-insulation-testers","description":"\u003cp\u003eThe MIT200 series will find applications in electrical contracting, both on domestic and industrial systems, as well as site maintenance and service departments.\u003c\/p\u003e\n\u003cp\u003eThe MIT200 series of insulation and continuity testers are ideal for testing transformers, motors, generators, switchgear, panel building, domestic appliances, power tools etc., as well as fixed electrical wiring systems.\u003c\/p\u003e\n\u003cp\u003eTheir small size and light weight make them ideal for those engineers that need to carry them for extended periods.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation testing to 1000 MΩ\u003c\/li\u003e\n\u003cli\u003eContinuity testing at 200 mA down to 0.01 Ω\u003c\/li\u003e\n\u003cli\u003eLive circuit warning (voltage display) and test inhibit\u003c\/li\u003e\n\u003cli\u003eDigital\/Analogue display\u003c\/li\u003e\n\u003cli\u003eAlkaline or rechargeable batteries\u003c\/li\u003e\n\u003cli\u003e–10°C to +55°C operating temperature\u003c\/li\u003e\n\u003cli\u003eCATIII 600 V\u003c\/li\u003e\n\u003cli\u003eConforms to EN61557-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"540\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"232\"\u003e \u003c\/td\u003e\n\u003ctd width=\"77\"\u003eMIT200\u003c\/td\u003e\n\u003ctd width=\"77\"\u003e\n\u003cp style=\"text-align: center;\"\u003eMIT210\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"77\"\u003e\n\u003cp style=\"text-align: center;\"\u003eMIT220\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"77\"\u003e\n\u003cp style=\"text-align: center;\"\u003eMIT230\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eInsulation Testing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 MΩ Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Ranging\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Discharge\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Inhibit\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive Circuit Voltage Display\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eContinuity Testing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity at \u0026gt;200 mA\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity to 0.01 Ω\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest lead null (9.99 Ω)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic continuity test\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity buzzer with 2 Ω threshold\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault volts warning \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital display + arc\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery condition\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto power down\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTough carry case\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest leads\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT III 600 V\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eLead set with prods and clips\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCarry case\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/MIT200_DS_us.pdf?1651\" target=\"_blank\" title=\"Megger MIT200 Series Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger MIT200 Series Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-07-25T08:48:41-06:00","created_at":"2019-07-25T08:57:10-06:00","vendor":"Megger","type":"Insulation Testers","tags":[],"price":49000,"price_min":49000,"price_max":96500,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16803778035755,"title":"MEG-MIT200-EN","option1":"MEG-MIT200-EN","option2":null,"option3":null,"sku":"MEG-MIT200-EN-5","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger MIT200 Series Insulation Testers - MEG-MIT200-EN","public_title":"MEG-MIT200-EN","options":["MEG-MIT200-EN"],"price":49000,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16803777904683,"title":"MEG-MIT210-EN","option1":"MEG-MIT210-EN","option2":null,"option3":null,"sku":"MEG-MIT200-EN-1","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger MIT200 Series Insulation Testers - MEG-MIT210-EN","public_title":"MEG-MIT210-EN","options":["MEG-MIT210-EN"],"price":53000,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16803777937451,"title":"MEG-MIT220-EN","option1":"MEG-MIT220-EN","option2":null,"option3":null,"sku":"MEG-MIT220-EN","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger MIT200 Series Insulation Testers - MEG-MIT220-EN","public_title":"MEG-MIT220-EN","options":["MEG-MIT220-EN"],"price":84000,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16803777970219,"title":"MEG-MIT230-EN","option1":"MEG-MIT230-EN","option2":null,"option3":null,"sku":"MEG-MIT230-EN","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger MIT200 Series Insulation Testers - MEG-MIT230-EN","public_title":"MEG-MIT230-EN","options":["MEG-MIT230-EN"],"price":96500,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16803778002987,"title":"MEG-MIT230-HD-EN","option1":"MEG-MIT230-HD-EN","option2":null,"option3":null,"sku":"MEG-MIT230-HD-EN","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger MIT200 Series Insulation Testers - MEG-MIT230-HD-EN","public_title":"MEG-MIT230-HD-EN","options":["MEG-MIT230-HD-EN"],"price":94500,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_MIT200.jpg?v=1564066633"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_MIT200.jpg?v=1564066633","options":["Model"],"media":[{"alt":null,"id":2806102949931,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_MIT200.jpg?v=1564066633"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Megger_MIT200.jpg?v=1564066633","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe MIT200 series will find applications in electrical contracting, both on domestic and industrial systems, as well as site maintenance and service departments.\u003c\/p\u003e\n\u003cp\u003eThe MIT200 series of insulation and continuity testers are ideal for testing transformers, motors, generators, switchgear, panel building, domestic appliances, power tools etc., as well as fixed electrical wiring systems.\u003c\/p\u003e\n\u003cp\u003eTheir small size and light weight make them ideal for those engineers that need to carry them for extended periods.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation testing to 1000 MΩ\u003c\/li\u003e\n\u003cli\u003eContinuity testing at 200 mA down to 0.01 Ω\u003c\/li\u003e\n\u003cli\u003eLive circuit warning (voltage display) and test inhibit\u003c\/li\u003e\n\u003cli\u003eDigital\/Analogue display\u003c\/li\u003e\n\u003cli\u003eAlkaline or rechargeable batteries\u003c\/li\u003e\n\u003cli\u003e–10°C to +55°C operating temperature\u003c\/li\u003e\n\u003cli\u003eCATIII 600 V\u003c\/li\u003e\n\u003cli\u003eConforms to EN61557-1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"540\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"232\"\u003e \u003c\/td\u003e\n\u003ctd width=\"77\"\u003eMIT200\u003c\/td\u003e\n\u003ctd width=\"77\"\u003e\n\u003cp style=\"text-align: center;\"\u003eMIT210\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"77\"\u003e\n\u003cp style=\"text-align: center;\"\u003eMIT220\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"77\"\u003e\n\u003cp style=\"text-align: center;\"\u003eMIT230\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eInsulation Testing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 MΩ Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Ranging\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Discharge\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Inhibit\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive Circuit Voltage Display\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eContinuity Testing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity at \u0026gt;200 mA\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity to 0.01 Ω\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest lead null (9.99 Ω)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic continuity test\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity buzzer with 2 Ω threshold\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault volts warning \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital display + arc\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery condition\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto power down\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTough carry case\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest leads\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT III 600 V\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eLead set with prods and clips\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCarry case\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/MIT200_DS_us.pdf?1651\" target=\"_blank\" title=\"Megger MIT200 Series Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger MIT200 Series Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger MIT200 Series Insulation Testers

Megger MIT200 Series Insulation Testers

$945.00 CAD

The MIT200 series will find applications in electrical contracting, both on domestic and industrial systems, as well as site maintenance and service departments. The MIT200 series of insulation and continuity testers are ideal for testing transformers, motors, generators, switchgear, panel building, domestic appliances, power tools etc., as well...


More Info