{ "id":1838518763563, "title":"Megger MIT300 Series Insulation Testers","handle":"megger-mit300-series-insulation-testers", "description":"\u003cp\u003eDeveloped, after extensive customer research, specifically to meet the needs of today’s electrical contractors, the new MIT300 range of insulation and continuity testers from Megger is not only durable and easy to use, but also incorporates a comprehensive set of features designed to ensure operator safety, even under conditions of accidental misuse.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp style=\"display: inline !important;\"\u003eThe range includes four models, ensuring an exact match for the needs of every user, all of which offer automatic discharge of the circuit after testing, audible and visual warning if the test probes are applied to a live circuit, and a test inhibit feature which operates automatically under live circuit conditions. The units also conform fully to IEC 61010-1 for use in Category III 600V applications, and provide all of the facilities needed to meet insulation testing requirements relating to the current edition of the IEE Wiring Regulations.\u003c\/p\u003e\n\u003cp\u003eIn line with other products in Megger's comprehensive new contractor range, MIT300 insulation testers feature rugged construction, with an impact-resistant rubber-overmoulded case, and innovative circuitry which guarantees high accuracy combined with stability of calibration.\u003c\/p\u003e\n\u003cp\u003eAll instruments in the new range provide indication of insulation resistance up to 999Mohms, 200mA continuity testing, a fast-reacting continuity buzzer, and facilities for nulling the resistance of the test leads. The entry-level MIT300 offers insulation test voltages of 250V and 500V, while the remaining models allow testing at 250V, 500V and 1,000V.\u003c\/p\u003e\n\u003cp\u003eIn addition to the basic features, the mid-range MIT310 adds a default voltmeter function, while the MIT320 supplements these facilities with an a backlit display, illuminated range panel, insulation limit alarm, resistance measurement, and an adjustable threshold for the continuity buzzer. The MEGIT320 is also supplied with a switched test probe to speed hands free testing.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAn illuminated switched test probe is available as an optional extra for use with the MIT320.\u003c\/p\u003e\n\u003cp\u003eThe MIT310, MIT320 and MIT330 testers incorporate dual solid-state displays which simultaneously show the test results numerically, and in the form of a moving-arc bar graph that accurately simulates the operation of an analogue meter.\u003c\/p\u003e\n\u003cp\u003eThe MIT330 additionally offers the facility to save test results to internal memory. Over 1000 result can be saved on site, and downloaded to a computer when convenient.\u003c\/p\u003e\n\u003cp\u003eData is stored in non-volatile memory, being retained when the instrument is switched off or batteries are exhausted.\u003c\/p\u003e\n\u003cp\u003eA Job reference number can be selected for a range of results, allowing separate locations to be tested with the same tester and easily separated when downloaded.\u003c\/p\u003e\n\u003cp\u003eA memory bar graph acts as a ‘Fuel Gauge’ showing how much memory has been used. Test results are downloaded to CSV (Coma Separated Variable) spreadsheets. If certificates or reports are required, the results can be downloaded directly into Megger Powersuite Professional with a range of features for creating professionally finished documentation.\u003c\/p\u003e\n\u003cp\u003eAll testers come complete with a full calibration certificate. For users who prefer a true analogue device, however, Megger is offering the MIT310A which has features similar to those of the MIT310, but with a conventional moving-coil meter movement in place of the digital display.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExtremely easy to use\u003c\/li\u003e\n\u003cli\u003eTough rubber armoured case\u003c\/li\u003e\n\u003cli\u003eSelf contained protective cover\u003c\/li\u003e\n\u003cli\u003eLive circuit warning\u003c\/li\u003e\n\u003cli\u003eWeatherproof to IP54\u003c\/li\u003e\n\u003cli\u003eIntelligent Safety System for protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"613\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd width=\"228\" style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd width=\"77\" style=\"height: 22px;\"\u003eMIT300 \u003c\/td\u003e\n\u003ctd width=\"77\" style=\"height: 22px;\"\u003eMIT310\u003c\/td\u003e\n\u003ctd width=\"77\" style=\"height: 22px;\"\u003eMIT310A \u003c\/td\u003e\n\u003ctd width=\"77\" style=\"height: 22px;\"\u003eMIT320\u003c\/td\u003e\n\u003ctd width=\"77\" style=\"height: 22px;\"\u003eMIT330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eInsulation testing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e250 V\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e500 V\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e1000 V\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eTest Range\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e999 MΩ\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e999 MΩ\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e999 MΩ\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e999 MΩ\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e999 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eInsulation Limit Alarm\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eContinuity Testing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eContinuity to 100 Ω\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 36px;\"\u003e\n\u003ctd style=\"height: 36px;\"\u003e\n\u003cp\u003eContinuity buzzer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"height: 36px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 36px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 36px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 36px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 36px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eLead null to 9 ohms\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e0.5Ω\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44px;\"\u003e\n\u003ctd style=\"height: 44px;\"\u003eAdjustable buzzer 1 to 20 Ω\u003c\/td\u003e\n\u003ctd style=\"height: 44px; text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 44px; text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 44px; text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 44px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 44px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eAudible buzzer disable\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eVoltage Measurement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eVolts AC\/DC\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e600 V\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e600 V\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e600 V\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44px;\"\u003e\n\u003ctd style=\"height: 44px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eResistance Measurement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"height: 44px;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e10 Ω to 1 Ω range\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"5\" style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eVoltage Warning\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eDefault Voltmeter\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eBacklit Display\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44px;\"\u003e\n\u003ctd style=\"height: 44px;\"\u003eBacklight Selector Ranges\u003c\/td\u003e\n\u003ctd style=\"height: 44px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 44px; text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 44px; text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 44px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 44px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eLocking Test Button\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eAuto Powerdown\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eSwitched Test Probe\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eIP54 Weatherproof\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 44px;\"\u003e\n\u003ctd style=\"height: 44px;\"\u003eAccepts Rechargeable Batteries\u003c\/td\u003e\n\u003ctd style=\"height: 44px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 44px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 44px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 44px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"height: 44px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 48px;\"\u003e\n\u003ctd style=\"height: 48px;\"\u003e1000 Test Result Storage\u003c\/td\u003e\n\u003ctd style=\"height: 48px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 48px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 48px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 48px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 48px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003eDownloading\u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"height: 22px; text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22px;\"\u003e\n\u003ctd style=\"height: 22px;\"\u003e3 Year Warranty\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 22px;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest Lead Set and Crocodile Clips\u003c\/li\u003e\n\u003cli\u003eSP4F Switch Probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/MIT300_DS_en_V15.pdf?1620\" target=\"_blank\" title=\"Megger MIT300 Series Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger MIT300 Series Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2019-07-23T09:01:04", "created_at":"2019-07-23T09:10:17", "vendor":"Megger", "type":"Insulation Testers", "tags":[], "price":112000, "price_min":112000, "price_max":148500, "price_varies":true, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[16796478111787,16796478144555,16796478177323,16796478210091,16796478242859], "variants":[{ "id":16796478111787, "product_id":1838518763563, "product_handle":"megger-mit300-series-insulation-testers", "title":"MEG-MIT300-EN", "option1":"MEG-MIT300-EN", "option2":null, "option3":null, "sku":"MEG-MIT300-EN", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Megger MIT300 Series Insulation Testers - MEG-MIT300-EN", "options":["MEG-MIT300-EN"], "price":116000, "weight":2268, "compare_at_price":null, "inventory_quantity":2, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":2, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":""},{ "id":16796478144555, "product_id":1838518763563, "product_handle":"megger-mit300-series-insulation-testers", "title":"MEG-MIT310-EN", "option1":"MEG-MIT310-EN", "option2":null, "option3":null, "sku":"MEG-MIT310-EN", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Megger MIT300 Series Insulation Testers - MEG-MIT310-EN", "options":["MEG-MIT310-EN"], "price":115000, "weight":2268, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":""},{ "id":16796478177323, "product_id":1838518763563, "product_handle":"megger-mit300-series-insulation-testers", "title":"MEG-MIT310A-EN", "option1":"MEG-MIT310A-EN", "option2":null, "option3":null, "sku":"MEG-MIT310A-EN", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Megger MIT300 Series Insulation Testers - MEG-MIT310A-EN", "options":["MEG-MIT310A-EN"], "price":112000, "weight":2268, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":""},{ "id":16796478210091, "product_id":1838518763563, "product_handle":"megger-mit300-series-insulation-testers", "title":"MEG-MIT320-EN", "option1":"MEG-MIT320-EN", "option2":null, "option3":null, "sku":"MEG-MIT320-EN", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Megger MIT300 Series Insulation Testers - MEG-MIT320-EN", "options":["MEG-MIT320-EN"], "price":136000, "weight":2268, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":""},{ "id":16796478242859, "product_id":1838518763563, "product_handle":"megger-mit300-series-insulation-testers", "title":"MEG-MIT330-EN", "option1":"MEG-MIT330-EN", "option2":null, "option3":null, "sku":"MEG-MIT330-EN", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Megger MIT300 Series Insulation Testers - MEG-MIT330-EN", "options":["MEG-MIT330-EN"], "price":148500, "weight":2268, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":""}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/MIT300.jpg?v=1563894621"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/MIT300.jpg?v=1563894621", "options":["Model"], "url":"\/products\/megger-mit300-series-insulation-testers"}

Megger MIT300 Series Insulation Testers

Product Description

Developed, after extensive customer research, specifically to meet the needs of today’s electrical contractors, the new MIT300 range of insulation and continuity testers from Megger is not only durable and easy to use, but also incorporates a comprehensive set of features designed to ensure operator safety, even under conditions of accidental misuse.

 

Sku: MEG-MIT300-EN
Vendor: Megger
2 left in stock.
$1,485.00 CAD
Maximum quantity available reached.

The range includes four models, ensuring an exact match for the needs of every user, all of which offer automatic discharge of the circuit after testing, audible and visual warning if the test probes are applied to a live circuit, and a test inhibit feature which operates automatically under live circuit conditions. The units also conform fully to IEC 61010-1 for use in Category III 600V applications, and provide all of the facilities needed to meet insulation testing requirements relating to the current edition of the IEE Wiring Regulations.

In line with other products in Megger's comprehensive new contractor range, MIT300 insulation testers feature rugged construction, with an impact-resistant rubber-overmoulded case, and innovative circuitry which guarantees high accuracy combined with stability of calibration.

All instruments in the new range provide indication of insulation resistance up to 999Mohms, 200mA continuity testing, a fast-reacting continuity buzzer, and facilities for nulling the resistance of the test leads. The entry-level MIT300 offers insulation test voltages of 250V and 500V, while the remaining models allow testing at 250V, 500V and 1,000V.

In addition to the basic features, the mid-range MIT310 adds a default voltmeter function, while the MIT320 supplements these facilities with an a backlit display, illuminated range panel, insulation limit alarm, resistance measurement, and an adjustable threshold for the continuity buzzer. The MEGIT320 is also supplied with a switched test probe to speed hands free testing.

 

An illuminated switched test probe is available as an optional extra for use with the MIT320.

The MIT310, MIT320 and MIT330 testers incorporate dual solid-state displays which simultaneously show the test results numerically, and in the form of a moving-arc bar graph that accurately simulates the operation of an analogue meter.

The MIT330 additionally offers the facility to save test results to internal memory. Over 1000 result can be saved on site, and downloaded to a computer when convenient.

Data is stored in non-volatile memory, being retained when the instrument is switched off or batteries are exhausted.

A Job reference number can be selected for a range of results, allowing separate locations to be tested with the same tester and easily separated when downloaded.

A memory bar graph acts as a ‘Fuel Gauge’ showing how much memory has been used. Test results are downloaded to CSV (Coma Separated Variable) spreadsheets. If certificates or reports are required, the results can be downloaded directly into Megger Powersuite Professional with a range of features for creating professionally finished documentation.

All testers come complete with a full calibration certificate. For users who prefer a true analogue device, however, Megger is offering the MIT310A which has features similar to those of the MIT310, but with a conventional moving-coil meter movement in place of the digital display.

  • Extremely easy to use
  • Tough rubber armoured case
  • Self contained protective cover
  • Live circuit warning
  • Weatherproof to IP54
  • Intelligent Safety System for protection
  MIT300  MIT310 MIT310A  MIT320 MIT330
Insulation testing  
250 V
500 V
1000 V  
Test Range 999 MΩ 999 MΩ 999 MΩ 999 MΩ 999 MΩ
Insulation Limit Alarm      
Continuity Testing  
Continuity to 100 Ω

Continuity buzzer

Lead null to 9 ohms 0.5Ω
Adjustable buzzer 1 to 20 Ω      
Audible buzzer disable      
Voltage Measurement  
Volts AC/DC   600 V 600 V 600 V 600 V
Resistance Measurement  
10 Ω to 1 Ω range      
Features  
Voltage Warning        
Default Voltmeter  
Backlit Display      
Backlight Selector Ranges      
Locking Test Button
Auto Powerdown  
Switched Test Probe      
IP54 Weatherproof
Accepts Rechargeable Batteries
1000 Test Result Storage        
Downloading        
3 Year Warranty  


  • Test Lead Set and Crocodile Clips
  • SP4F Switch Probe