{ "id":1253384290347, "title":"Fluke 123B Industrial ScopeMeter® Hand-Held Oscilloscope, 2 Channel, 20MHz","handle":"fluke-123-industrial-scopemeter", "description":"\u003cp\u003e\u003cspan\u003eThe compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input digital oscilloscope and multimeter\u003c\/li\u003e\n\u003cli\u003e20 MHz oscilloscope bandwidth\u003c\/li\u003e\n\u003cli\u003eTwo 5,000-count true-rms digital multimeters\u003c\/li\u003e\n\u003cli\u003eConnect-and-View™ trigger simplicity for hands-off operation; IntellaSet™ technology automatically and intelligently adjusts numerical readout\u003c\/li\u003e\n\u003cli\u003eDual-input waveform and meter reading recorder for trending data over extended periods\u003c\/li\u003e\n\u003cli\u003eRecorder Event Detect captures elusive intermittent signals\u003c\/li\u003e\n\u003cli\u003eWiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app*\u003c\/li\u003e\n\u003cli\u003eFlukeView® ScopeMeter® Software for Windows® (FLU-123B\/NA\/S)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eTrigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen update\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFree run, on trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA, B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eSensitivity A and B\u003c\/td\u003e\n\u003ctd\u003e@ DC to 5 MHz\u003c\/td\u003e\n\u003ctd\u003e0.5 divisions or 5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" rowspan=\"2\"\u003e@ 40 MHz\u003c\/td\u003e\n\u003ctd\u003e123B: 4 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 1.5 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" rowspan=\"2\"\u003e@ 60 MHz\u003c\/td\u003e\n\u003ctd\u003e123B: N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 4 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePositive, negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAdvanced scope functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eDisplay modes\u003c\/td\u003e\n\u003ctd\u003eNormal\u003c\/td\u003e\n\u003ctd\u003eCaptures up to 25 ns glitches and displays analog-like persistence waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eSmooth\u003c\/td\u003e\n\u003ctd\u003eSuppresses noise from a waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eGlitch off\u003c\/td\u003e\n\u003ctd\u003eDoes not capture glitches between samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEnvelope\u003c\/td\u003e\n\u003ctd\u003eRecords and displays the minimum and maximum of waveforms over time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto set (Connect-and-View™)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eContinuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eInput A and input B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC voltage (VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.5% +5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection (CMRR)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;100 dB @ dc, \u0026gt;60 dB @ 50, 60, or 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eTrue-rms voltages (V ac and V ac+dc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy for 5% to 100% of range (DC coupled)\u003c\/td\u003e\n\u003ctd\u003eDC to 60 Hz (V ac+dc)\u003c\/td\u003e\n\u003ctd\u003e±(1% +10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e1 Hz to 60 Hz (V ac)\u003c\/td\u003e\n\u003ctd\u003e±(1% +10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy for 5% to 100% of range (AC or dc coupled)\u003c\/td\u003e\n\u003ctd\u003e60 Hz to 20 kHz\u003c\/td\u003e\n\u003ctd\u003e±(2.5% +15 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC rejection (only VAC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;50 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCommon mode rejection (CMRR)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;100 dB @ dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e\u0026gt;60 dB @ 50, 60, or 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts, reading is independent of any signal crest factor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePeak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMax peak, Min peak, or pk-to-pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 2200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eAccuracy Max peak or Min peak\u003c\/td\u003e\n\u003ctd\u003e5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy Peak-to-Peak\u003c\/td\u003e\n\u003ctd\u003e10% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eRecorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMeter readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Speed\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMaximum 2 measurement\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size (min, max, average)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 M readings for 1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eWaveform record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum sample rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 K sample\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize Internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 M samples Recorded Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 minutes at 500 μs\/div\u003cbr\u003e11 hours at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5 G samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e11 hours at 500 μs\/div\u003cbr\u003e14 days at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003ePower Quality (125B only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWatt, VA, var, PF, DPF, Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eWatt, VA, var ranges (auto)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e250 W to 250 MW, 625 MW, 1.56 GW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: total (% r)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 6 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: fundamental (% f)\u003c\/td\u003e\n\u003ctd\u003e±(4% + 4 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDPF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00, ±0.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10.0 Hz to 15.0 kHz\u003cbr\u003e40.0 Hz to 70.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Harmonics\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDC to 51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings \/ Cursor readings \u003cbr\u003e(fundamental 40 Hz to 70 Hz)\u003c\/td\u003e\n\u003ctd\u003eVrms \/ Arms \/Watt\u003c\/td\u003e\n\u003ctd\u003eEach harmonic from fundamental maybe selected for individual readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eIncludes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOscilloscope\u003c\/li\u003e\n\u003cli\u003eAccessory List\u003c\/li\u003e\n\u003cli\u003eCD\u003c\/li\u003e\n\u003cli\u003eSafety Manual\u003c\/li\u003e\n\u003cli\u003eBanana to BNC Adapter\u003c\/li\u003e\n\u003cli\u003ePower Adapter\u003c\/li\u003e\n\u003cli\u003eShield Test Leads with Black ground Leads\u003c\/li\u003e\n\u003cli\u003eTL175 Test Leads\u003c\/li\u003e\n\u003cli\u003eBattery\u003c\/li\u003e\n\u003cli\u003eWiFi Dongle\u003c\/li\u003e\n\u003cli\u003eLine Cord\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_ScopeMeter_Brochure_-_120_Series_190_Series.PDF?1800\" target=\"_blank\" title=\"Fluke 123B Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 123B Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-05-11T13:46:38", "created_at":"2018-05-11T13:49:39", "vendor":"Fluke", "type":"Oscilloscopes", "tags":[], "price":262479, "price_min":262479, "price_max":341767, "price_varies":true, "compare_at_price":208100, "compare_at_price_min":208100, "compare_at_price_max":208100, "compare_at_price_varies":false, "all_variant_ids":[30250850320427,30250853466155], "variants":[{ "id":30250850320427, "product_id":1253384290347, "product_handle":"fluke-123-industrial-scopemeter", "title":"FLU-123B\/NA", "option1":"FLU-123B\/NA", "option2":null, "option3":null, "sku":"FLU-123B\/NA", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 123B Industrial ScopeMeter® Hand-Held Oscilloscope, 2 Channel, 20MHz - FLU-123B\/NA", "options":["FLU-123B\/NA"], "price":262479, "weight":4536, "compare_at_price":208100, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969814737"},{ "id":30250853466155, "product_id":1253384290347, "product_handle":"fluke-123-industrial-scopemeter", "title":"FLU-123B\/NA\/S", "option1":"FLU-123B\/NA\/S", "option2":null, "option3":null, "sku":"FLU-123B\/NA\/S", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 123B Industrial ScopeMeter® Hand-Held Oscilloscope, 2 Channel, 20MHz - FLU-123B\/NA\/S", "options":["FLU-123B\/NA\/S"], "price":341767, "weight":4536, "compare_at_price":208100, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969814973"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Osciloscopio-ScopeMeter-Portatil-20-MHz-MPP-Fluke-123-008-6470888.jpg?v=1526068181"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Osciloscopio-ScopeMeter-Portatil-20-MHz-MPP-Fluke-123-008-6470888.jpg?v=1526068181", "options":["Model"], "url":"\/products\/fluke-123-industrial-scopemeter"}

Fluke 123B Industrial ScopeMeter® Hand-Held Oscilloscope, 2 Channel, 20MHz

Product Description

The compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.

Sku: FLU-123B/NA
Vendor: Fluke
On Back-Order
$3,417.67 CAD

Features

  • Dual-input digital oscilloscope and multimeter
  • 20 MHz oscilloscope bandwidth
  • Two 5,000-count true-rms digital multimeters
  • Connect-and-View™ trigger simplicity for hands-off operation; IntellaSet™ technology automatically and intelligently adjusts numerical readout
  • Dual-input waveform and meter reading recorder for trending data over extended periods
  • Recorder Event Detect captures elusive intermittent signals
  • WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app*
  • FlukeView® ScopeMeter® Software for Windows® (FLU-123B/NA/S)

 

Trigger
Screen update Free run, on trigger
Source A, B
Sensitivity A and B @ DC to 5 MHz 0.5 divisions or 5 mV
@ 40 MHz 123B: 4 divisions
124B and 125B: 1.5 divisions
@ 60 MHz 123B: N/A
124B and 125B: 4 divisions
Slope Positive, negative

 

Advanced scope functions
Display modes Normal Captures up to 25 ns glitches and displays analog-like persistence waveform
Smooth Suppresses noise from a waveform
Glitch off Does not capture glitches between samples
Envelope Records and displays the minimum and maximum of waveforms over time
Auto set (Connect-and-View™) Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.

 

Input A and input B
DC voltage (VDC)
Ranges 500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy ±(0.5% +5 counts)
Common mode rejection (CMRR) >100 dB @ dc, >60 dB @ 50, 60, or 400 Hz
Full scale reading 5000 counts
True-rms voltages (V ac and V ac+dc)
Ranges 500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy for 5% to 100% of range (DC coupled) DC to 60 Hz (V ac+dc) ±(1% +10 counts)
1 Hz to 60 Hz (V ac) ±(1% +10 counts)
Accuracy for 5% to 100% of range (AC or dc coupled) 60 Hz to 20 kHz ±(2.5% +15 counts)
DC rejection (only VAC) >50 dB
Common mode rejection (CMRR) >100 dB @ dc
>60 dB @ 50, 60, or 400 Hz
Full scale reading 5000 counts, reading is independent of any signal crest factor.
Peak
Modes Max peak, Min peak, or pk-to-pk
Ranges 500 mV, 5 V, 50 V, 500 V, 2200 V
Accuracy Accuracy Max peak or Min peak 5% of full scale
Accuracy Peak-to-Peak 10% of full scale
Full scale reading 500 counts

Recorder
The recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B).
The results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples.
Meter readings
Measurement Speed Maximum 2 measurement/s
Record Size (min, max, average) 2 M readings for 1 channel
Recorded Time Span 2 weeks
Maximum number of events 1024
Waveform record
Maximum sample rate 400 K sample/s
Size Internal memory 400 M samples Recorded Time
Span internal memory 15 minutes at 500 μs/div
11 hours at 20 ms/div
Record Size SD card 1.5 G samples
Recorded Time Span SD card 11 hours at 500 μs/div
14 days at 20 ms/div
Maximum number of events 64

 

Power Quality (125B only)
Readings Watt, VA, var, PF, DPF, Hz
Watt, VA, var ranges (auto) 250 W to 250 MW, 625 MW, 1.56 GW
When selected: total (% r) ±(2% + 6 counts)
When selected: fundamental (% f) ±(4% + 4 counts)
DPF 0.00 to 1.00
PF 0.00 to 1.00, ±0.04
Frequency range 10.0 Hz to 15.0 kHz
40.0 Hz to 70.0 Hz
Number of Harmonics DC to 51
Readings / Cursor readings 
(fundamental 40 Hz to 70 Hz)
Vrms / Arms /Watt Each harmonic from fundamental maybe selected for individual readings
Includes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)

 

  • Oscilloscope
  • Accessory List
  • CD
  • Safety Manual
  • Banana to BNC Adapter
  • Power Adapter
  • Shield Test Leads with Black ground Leads
  • TL175 Test Leads
  • Battery
  • WiFi Dongle
  • Line Cord

Related Products