{ "id":1038411464747, "title":"Fluke 1550C 5kV Digital Insulation Tester","handle":"fluke-1550c-5kv-insulation-resistance-tester", "description":"\u003cp\u003e\u003cspan\u003eThe Fluke 1550C performs digital insulation testing up to 5 kV, and makes the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTrust the best name in the business for all your insulation testing with the Fluke 1550C. With advanced testing methods, reporting, and best-in-class performance, this is the number one insulation tester in the industry. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage (DC)\u003c\/td\u003e\n\u003ctd\u003eRange (DC)\u003c\/td\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e250 kΩ to 5 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 GΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 50 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e500 kΩ to 10 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 GΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 100 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e1 MΩ to 20 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20 GΩ to 200 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 200 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e50 GΩ to 500 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 500 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 MΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e100 GΩ to 1 TΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 1 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLeakage Current Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 nA to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (5 % + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCapacitance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 uF to 15.00°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (15 % rdg + 0.03°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest cables with alligator clips (red, black, green)\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC power cord\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eEnglish manual\u003c\/li\u003e\n\u003cli\u003eUser's manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eQuick reference card\u003c\/li\u003e\n\u003cli\u003eSoftware license agreement\u003c\/li\u003e\n\u003cli\u003eRegistration card\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms installation guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR cable installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1550-1555_Spec.pdf?1595\" target=\"_blank\" title=\"Fluke 1550C Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1550C Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-02-21T14:50:18", "created_at":"2018-02-21T14:54:58", "vendor":"Fluke", "type":"Insulation Testers", "tags":[], "price":856799, "price_min":856799, "price_max":943295, "price_varies":true, "compare_at_price":653300, "compare_at_price_min":653300, "compare_at_price_max":653300, "compare_at_price_varies":false, "all_variant_ids":[10706613174315,16793563627563,16793569198123], "variants":[{ "id":10706613174315, "product_id":1038411464747, "product_handle":"fluke-1550c-5kv-insulation-resistance-tester", "title":"1550C", "option1":"1550C", "option2":null, "option3":null, "sku":"FLU-1550C", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 1550C 5kV Digital Insulation Tester - 1550C", "options":["1550C"], "price":856799, "weight":6804, "compare_at_price":653300, "inventory_quantity":1, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":1, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969550918"},{ "id":16793563627563, "product_id":1038411464747, "product_handle":"fluke-1550c-5kv-insulation-resistance-tester", "title":"1550C\/KIT", "option1":"1550C\/KIT", "option2":null, "option3":null, "sku":"FLU-1550C\/KIT", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 1550C 5kV Digital Insulation Tester - 1550C\/KIT", "options":["1550C\/KIT"], "price":943295, "weight":6804, "compare_at_price":653300, "inventory_quantity":1, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":1, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969550987"},{ "id":16793569198123, "product_id":1038411464747, "product_handle":"fluke-1550c-5kv-insulation-resistance-tester", "title":"1550C FC", "option1":"1550C FC", "option2":null, "option3":null, "sku":"FLU-1550C FC", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 1550C 5kV Digital Insulation Tester - 1550C FC", "options":["1550C FC"], "price":872167, "weight":6804, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969868785"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C.jpg?v=1562783826","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C_BHD.jpg?v=1562783826","\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-1550c-01b-s.jpg?v=1562783826"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C.jpg?v=1562783826", "options":["Model"], "url":"\/products\/fluke-1550c-5kv-insulation-resistance-tester"}
Fluke 1550C 5kV Digital Insulation Tester
Product Description
The Fluke 1550C performs digital insulation testing up to 5 kV, and makes the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur.
Trust the best name in the business for all your insulation testing with the Fluke 1550C. With advanced testing methods, reporting, and best-in-class performance, this is the number one insulation tester in the industry.
Sku: FLU-1550C
Vendor: Fluke
1 left in stock.
Overview
- Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
- Guard system eliminates the effect of surface leakage current on high-resistance measurements
- Selectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V
- CAT III 1000 V, CAT IV 600 V safety rating
- Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
- Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
- Long battery life gives the user over 750 tests between charges
- Large digital/analog LCD for easy viewing
- Capacitance and leakage current measurement
- Ramp function for breakdown testing
- Resistance measurements up to 2 TΩ
- Timer settings up to 99 minutes for timed tests
- 3-year warranty
Specifications
Insulation Resistance | ||
Test voltage (DC) | Range (DC) | Accuracy (± reading) |
250 V | < 250 kΩ 250 kΩ to 5 GΩ 5 GΩ to 50 GΩ > 50 GΩ |
Unspecified 5% 20% Unspecified |
500 V | < 500 kΩ 500 kΩ to 10 GΩ 10 GΩ to 100 GΩ > 100 GΩ |
Unspecified 5% 20% Unspecified |
1000 V | < 1 MΩ 1 MΩ to 20 GΩ 20 GΩ to 200 GΩ > 200 GΩ |
Unspecified 5% 20% Unspecified |
2500 V | < 2.5 MΩ 2.5 MΩ to 50 GΩ 50 GΩ to 500 GΩ > 500 GΩ |
Unspecified 5% 20% Unspecified |
5000 V | < 5 MΩ 5 MΩ to 100 GΩ 100 GΩ to 1 TΩ > 1 TΩ |
Unspecified 5% 20% Unspecified |
Leakage Current Measurement | ||
Range | 1 nA to 2 mA | |
Accuracy | ± (5 % + 2 nA) | |
Capacitance Measurement | ||
Range | 0.01 uF to 15.00°F | |
Accuracy | ± (15 % rdg + 0.03°F) |
What's in the Box
- Test cables with alligator clips (red, black, green)
- Infrared adapter with interface cable
- FlukeView® Forms Basic CD-ROM
- AC power cord
- Soft carrying case
- English manual
- User's manual on CD-ROM
- Quick reference card
- Software license agreement
- Registration card
- FlukeView® Forms installation guide
- USB-IR cable installation guide
Resources
Related Products
Fluke 9009 Dual Dry Block Temperature Calibrator
$11,536.88 CAD
Fluke IRR1-SOL Solar Irradiance Meter
$571.28 CAD
Fluke 417D Laser Distance Meter
$201.27 CAD
Fluke 1770 Series Three-Phase Power Quality Analyzers
From $11,527.35 CAD
Fluke 190 Series III ScopeMeters®
From $6,195.00 CAD
Fluke ii910 Precision Acoustic Imager
$29,120.00 CAD
Fluke 377FC Non-Contact True RMS AC/DC Clamp Meter
$1,060.79 CAD