{ "id":1069091061803, "title":"Fluke 52 II Dual Probe Digital Thermometer","handle":"fluke-52-ii-thermometer", "description":"\u003cp\u003e\u003cspan\u003eThe Fluke 52 II dual-input digital thermometer delivers fast response with laboratory accuracy (0.05% + 0.3°C). You can use the 52 II to measure two contact temperature inputs simultaneously on motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, or E-type thermocouple temperature sensors. The user friendly-front panel and large, backlit display make it easy to view results from both inputs in multiple ways. And the sleep mode feature preserves battery life to give you a typical thousand hours of operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input digital thermometer for lab, QA, process calibration, food safety and HVAC\u003c\/li\u003e\n\u003cli\u003eShows any combination of T1, T2, T1-T2, plus MIN, MAX, or AVG on the large backlit dual display\u003c\/li\u003e\n\u003cli\u003eFeatures fast response and laboratory accuracy (0.05% + 0.3°C)\u003c\/li\u003e\n\u003cli\u003eIncludes a relative time clock on MIN, MAX, and AVG to provide a time reference for major events\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eTemperature accuracy\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cb\u003eAbove -100°C\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eJ, K, T, E, and N-type: ±[0.05% + 0.3°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR and S-type: ±[0.05% + 0.4°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cb\u003eBelow -100°C\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eJ, K, E, and N-types: ±[0.20% + 0.3°C]\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT-type: ±[0.50% + 0.3°C]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eJ-type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-210°C to 1200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-type\u003c\/td\u003e\n\u003ctd\u003e-200°C to 1372°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT-type\u003c\/td\u003e\n\u003ctd\u003e-250°C to 400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE-type\u003c\/td\u003e\n\u003ctd\u003e-150°C to 1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN-type\u003c\/td\u003e\n\u003ctd\u003e-200°C to 1300°C\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR and S-type\u003c\/td\u003e\n\u003ctd\u003e0°C to 1767°C\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature scale\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eITS-90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable standards\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNIST-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C, 0.1 K \u0026lt; 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e1°C, 1 K ≥ 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"3\"\u003e1. Only the Fluke Models 53 II B and 54 II Bthermometers are capable of measuring N, R, and S-type thermocouples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHumidity (without condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% to 90%; 0°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 70%; 0°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCE, CSA, TÜV (pending)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (L x W x D)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e173 x 86 x 38 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 AA batteries; typical 1000-hour life\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eImpact absorbing holster\u003c\/li\u003e\n\u003cli\u003eTwo 80PK-1 beaded probe thermocouples\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_50_Series_Thermometer.pdf?1832\" target=\"_blank\" title=\"Fluke 52 II Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 52 II Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-03-05T14:59:33", "created_at":"2018-03-05T15:02:22", "vendor":"Fluke", "type":"Digital Thermometers", "tags":[], "price":75751, "price_min":75751, "price_max":75751, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[11001036636203], "variants":[{ "id":11001036636203, "product_id":1069091061803, "product_handle":"fluke-52-ii-thermometer", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"FLU-52-2", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 52 II Dual Probe Digital Thermometer - Default Title", "options":["Default Title"], "price":75751, "weight":2268, "compare_at_price":null, "inventory_quantity":3, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":3, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969071338"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-52-2-d40.jpg?v=1520287344"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-52-2-d40.jpg?v=1520287344", "options":["Title"], "url":"\/products\/fluke-52-ii-thermometer"}

Fluke 52 II Dual Probe Digital Thermometer

Product Description

The Fluke 52 II dual-input digital thermometer delivers fast response with laboratory accuracy (0.05% + 0.3°C). You can use the 52 II to measure two contact temperature inputs simultaneously on motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, or E-type thermocouple temperature sensors. The user friendly-front panel and large, backlit display make it easy to view results from both inputs in multiple ways. And the sleep mode feature preserves battery life to give you a typical thousand hours of operation.

Sku: FLU-52-2
Vendor: Fluke
3 left in stock.
$757.51 CAD
Maximum quantity available reached.

Key features

  • Dual-input digital thermometer for lab, QA, process calibration, food safety and HVAC
  • Shows any combination of T1, T2, T1-T2, plus MIN, MAX, or AVG on the large backlit dual display
  • Features fast response and laboratory accuracy (0.05% + 0.3°C)
  • Includes a relative time clock on MIN, MAX, and AVG to provide a time reference for major events
Specifications
Temperature accuracy Above -100°C J, K, T, E, and N-type: ±[0.05% + 0.3°C]1
R and S-type: ±[0.05% + 0.4°C]1
Below -100°C J, K, E, and N-types: ±[0.20% + 0.3°C]1
T-type: ±[0.50% + 0.3°C]
Temperature J-type -210°C to 1200°C
K-type -200°C to 1372°C
T-type -250°C to 400°C
E-type -150°C to 1000°C
N-type -200°C to 1300°C1
R and S-type 0°C to 1767°C1
Temperature scale ITS-90
Applicable standards NIST-175
Display resolution 0.1°C, 0.1 K < 1000
1°C, 1 K ≥ 1000
1. Only the Fluke Models 53 II B and 54 II Bthermometers are capable of measuring N, R, and S-type thermocouples.
Environmental Specifications
Operating temperature -10°C to 50°C
Storage temperature -40°C to 60°C
Humidity (without condensation) 0% to 90%; 0°C to 35°C
0% to 70%; 0°C to 50°C
Safety Specifications
Overvoltage category CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2
Agency approvals CE, CSA, TÜV (pending)
Mechanical and General Specifications
Size (L x W x D) 173 x 86 x 38 mm
Weight 400 g
Batteries 3 AA batteries; typical 1000-hour life


Includes:

  • Impact absorbing holster
  • Two 80PK-1 beaded probe thermocouples

Related Products