{ "id":1072541663275, "title":"Fluke 77 IV Digital Multimeter","handle":"fluke-77-4-series-digital-multimeter", "description":"\u003cp\u003e\u003cstrong\u003eVersatile meters for field service or bench repair.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 77 IV digital multimeter has the features needed to repair most electrical and electronic problems. This meter is simple to use and has significant improvements over Fluke's original 70 Series with more measurement functions, conformance to the latest safety standards, and a much larger display that's easier to view.\u003c\/p\u003e\n\u003cp\u003eIt measures:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWide 1000 V measurement range\u003c\/li\u003e\n\u003cli\u003eAverage responding AC measurements\u003c\/li\u003e\n\u003cli\u003e0.3% accuracy\u003c\/li\u003e\n\u003cli\u003e10 Amps continuous (20 A for 30 seconds)\u003c\/li\u003e\n\u003cli\u003eFrequency and capacitance\u003c\/li\u003e\n\u003cli\u003eResistance and continuity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cul\u003e\n\u003cli\u003eLarge display\u003c\/li\u003e\n\u003cli\u003eBacklight for work in dim areas\u003c\/li\u003e\n\u003cli\u003eMin \/ Max to record signal fluctuations\u003c\/li\u003e\n\u003cli\u003eErgonomic overmolded housing with integrated probe holders\u003c\/li\u003e\n\u003cli\u003eFree your hands with the optional TPAK magnetic hanger\u003c\/li\u003e\n\u003cli\u003eAuto and Manual ranging\u003c\/li\u003e\n\u003cli\u003eMeets Measurement Category 1000 V CAT III and Category IV 600 V safety standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 77 IV replaces the 77. Move up to superior utility and safety today.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V – 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.3% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage AC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV – 1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest accuracy\u003c\/td\u003e\n\u003ctd\u003e±(2.0% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest resolution\u003c\/td\u003e\n\u003ctd\u003e1.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAmps AC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e60.00 mA – 10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest accuracy\u003c\/td\u003e\n\u003ctd\u003e2.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAmps DC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e60.00 mA – 10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest accuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω – 50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.5% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1nF – 9,999 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest accuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest resolution\u003c\/td\u003e\n\u003ctd\u003e1 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e99.99Hz – 99.99kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.1% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eANSI \/ ISA S82.02.01, CSA C22.2–1010.1, IEC 61010 to 1000 V Measurement Category III, 600 V Measurement Category IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA, TÜV (EN61010), Π, (N10140)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 kV peak per IEC 61010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eΩ Fuse for mA inputs\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e440 mA, 1000 V FAST Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eΩ Fuse for A inputs\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e11 A, 1000 V FAST Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eDigital\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 counts, updates 4\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar graph\u003c\/td\u003e\n\u003ctd\u003e33 segments, updates 32\/sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e10,000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e1,000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOperating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2,000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e12,000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOperating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to + 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-40°C to + 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1 x (specified accuracy \/ °C (\u0026lt; 18°C or \u0026gt; 28°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003cbr\u003e(EN 61326–1:1997)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIn an RF field of 3 V\/M, accuracy = specified accuracy except in temperature:\u003cbr\u003especified accuracy ±5°C (9°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003cbr\u003e(maximum non-condensing)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e90% to 35°C\u003cbr\u003e75% to 40°C\u003cbr\u003e45% to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 hours typical (alkaline)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4.3 x 9 x 18.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e420 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstalled 9V battery\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eUsers manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_77_IV_Spec_Sheet.PDF?1854\" target=\"_blank\" title=\"Fluke 77 IV Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 77 IV Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-03-06T16:57:49", "created_at":"2018-03-06T17:00:33", "vendor":"Fluke", "type":"Multimeters", "tags":[], "price":56439, "price_min":56439, "price_max":56439, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[11020580290603], "variants":[{ "id":11020580290603, "product_id":1072541663275, "product_handle":"fluke-77-4-series-digital-multimeter", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"FLU-77-4", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 77 IV Digital Multimeter - Default Title", "options":["Default Title"], "price":56439, "weight":2268, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969365239"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke_77-4-0.jpg?v=1520380834","\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke774__1.jpg?v=1520380836"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke_77-4-0.jpg?v=1520380834", "options":["Title"], "url":"\/products\/fluke-77-4-series-digital-multimeter"}
Fluke 77 IV Digital Multimeter
Product Description
Versatile meters for field service or bench repair.
The Fluke 77 IV digital multimeter has the features needed to repair most electrical and electronic problems. This meter is simple to use and has significant improvements over Fluke's original 70 Series with more measurement functions, conformance to the latest safety standards, and a much larger display that's easier to view.
It measures:
- Wide 1000 V measurement range
- Average responding AC measurements
- 0.3% accuracy
- 10 Amps continuous (20 A for 30 seconds)
- Frequency and capacitance
- Resistance and continuity
Sku: FLU-77-4
Vendor: Fluke
On Back-Order
Overview
Key features
- Large display
- Backlight for work in dim areas
- Min / Max to record signal fluctuations
- Ergonomic overmolded housing with integrated probe holders
- Free your hands with the optional TPAK magnetic hanger
- Auto and Manual ranging
- Meets Measurement Category 1000 V CAT III and Category IV 600 V safety standards
The 77 IV replaces the 77. Move up to superior utility and safety today.
Specifications
Specifications | ||
Voltage DC | Range | 6.000 V – 1000 V |
Best accuracy | ±(0.3% + 1) | |
Best resolution | 0.1 mV | |
Voltage AC | Range | 600.0 mV – 1000V |
Best accuracy | ±(2.0% + 2) | |
Best resolution | 1.0 mV | |
Amps AC | Range | 60.00 mA – 10 A |
Best accuracy | 2.5% + 2 | |
Best resolution | 0.01 mA | |
Amps DC | Range | 60.00 mA – 10A |
Best accuracy | 1.5% + 2 | |
Best resolution | 0.01 mA | |
Resistance | Range | 600.0 Ω – 50 MΩ |
Best accuracy | ±(0.5% + 1) | |
Best resolution | 0.1 Ω | |
Capacitance | Range | 1nF – 9,999 μF |
Best accuracy | ±(1.2% + 2) | |
Best resolution | 1 nF | |
Frequency | Range | 99.99Hz – 99.99kHz |
Best accuracy | ±(0.1% + 1) | |
Best resolution | 0.01 Hz | |
Safety | ANSI / ISA S82.02.01, CSA C22.2–1010.1, IEC 61010 to 1000 V Measurement Category III, 600 V Measurement Category IV | |
Certifications | CSA, TÜV (EN61010), Π, (N10140) | |
General Specifications | ||
Maximum voltage between any terminal and earth ground | 1000 V | |
Surge protection | 8 kV peak per IEC 61010 | |
Ω Fuse for mA inputs | 440 mA, 1000 V FAST Fuse | |
Ω Fuse for A inputs | 11 A, 1000 V FAST Fuse | |
Display | Digital | 6000 counts, updates 4/sec |
Bar graph | 33 segments, updates 32/sec | |
Frequency | 10,000 counts | |
Capacitance | 1,000 counts | |
Altitude | Operating | 2,000 meters |
Storage | 12,000 meters | |
Temperature | Operating | -10°C to + 50°C |
Storage | -40°C to + 60°C | |
Temperature coefficient | 0.1 x (specified accuracy / °C (< 18°C or > 28°C) | |
Electromagnetic compatibility (EN 61326–1:1997) |
In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: specified accuracy ±5°C (9°F) |
|
Relative humidity (maximum non-condensing) |
90% to 35°C 75% to 40°C 45% to 50°C |
|
Battery life | 400 hours typical (alkaline) | |
Size (H x W x L) | 4.3 x 9 x 18.5 cm | |
Weight | 420 g |
What's in the Box
Includes:
- Installed 9V battery
- Test leads
- Users manual
Resources
Related Products
Fluke iSee Thermal Imager Attachment TC01A/TC01B
$679.99 CAD
Fluke 302+ AC Clamp Meter 600V, 400A (Average Responding)
$176.00 CAD $234.00 CAD
Fluke 17B+ Digital Multimeter with Temperature (Average Responding)
$225.00 CAD $323.00 CAD
Fluke 15B+ Digital Multimeter (Average Responding)
$175.00 CAD $224.00 CAD
Fluke 9009 Dual Dry Block Temperature Calibrator
$11,536.88 CAD
Fluke IRR1-SOL Solar Irradiance Meter
$571.28 CAD
Fluke 417D Laser Distance Meter
$201.27 CAD
Fluke 1770 Series Three-Phase Power Quality Analyzers
From $11,527.35 CAD
Fluke 190 Series III ScopeMeters®
From $6,195.00 CAD