{ "id":1054037278763, "title":"Fluke 87V\/E2 Industrial Electrician Combo Kit","handle":"fluke-87v-e2-industrial-electrician-combo-kit", "description":"\u003cp\u003e\u003cspan\u003eIdeal for electricians, this combo kit is built around the Fluke 87V, the most widely used industrial digital multimeter in the world and includes essential accessories to make you even more productive. This kit offers 15% savings compared with the individual price of all the accessories. Plus you'll be working with the most trusted tools in the world.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\"\u003e\n\u003cp\u003eAll functionality of the 87V Industrial Digital Multimeter, plus:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFully insulated 3 mm exposed metal test probes for electricians working in high energy environments\u003c\/li\u003e\n\u003cli\u003eC35 Soft Carrying Case holds meter, test leads and other accessories\u003c\/li\u003e\n\u003cli\u003eTPAK magnetic hanging strap lets you attach the meter to any ferrous surface, such as cabinets and iron pipes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eVoltage DC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.05% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e10 µV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eVoltage AC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Voltage\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.7% + 2) True RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Bandwidth\u003c\/td\u003e\n\u003ctd\u003e20 kHz with low pass filter; 3 db @ 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent DC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Amps\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A (20 A for 30 seconds maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCurrent AC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Amps\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A (20 A for 30 seconds maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmps Accuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 2) True RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Resistance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e50 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Capacitance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e9,999 µF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Frequency\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e200 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.005% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Duty Cycle\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e99.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(0.2% per khz +0.1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Measurement\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-200.0°C - 1090°C\u003cbr\u003e-328.0°F - 1994.0°F\u003cbr\u003eexcluding probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80 BK Temperature Probe\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40.0°C - 260°C\u003cbr\u003e-40.0°F - 500°F, 2.2°C or 2% whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eConductance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMaximum Conductance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e60.00 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 nS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDiode\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e3 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% + 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle Range\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAccuracy\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eWithin ±(02% per kHz +0.1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEnvironmental Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity (Without Condensation)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0% - 90% (0°C - 35°C)\u003cbr\u003e0% - 70% (35°C - 55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSafety Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61010-1 to 1000 V CAT III, 600V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eUL, CSA, TÜV, VDE listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e201 x 98 x 52 mm (with holster)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e355 g\u003cbr\u003e624 g - with holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eDigital\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6000 counts updates 4\/sec.\u003cbr\u003e19,999 counts in high-resolution mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog\u003c\/td\u003e\n\u003ctd\u003e32 segments, updates 40\/sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e19,999 counts, updates 3\/sec at \u0026gt; 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLifetime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eAlkaline\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e~400 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 Meter drop per IEC 61010-1:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePer MIL-PRF-28800 for a Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e87V Industrial Multimeter\u003c\/li\u003e\n\u003cli\u003eTL224 SureGrip™ Insulated Test Leads\u003c\/li\u003e\n\u003cli\u003eAC220 SureGrip™ Alligator Clips\u003c\/li\u003e\n\u003cli\u003eTL238 SureGrip™ Test Probes\u003c\/li\u003e\n\u003cli\u003eToolPak™ Magnetic Meter Hanging Kit\u003c\/li\u003e\n\u003cli\u003e80BK-A DMM Temperature Probe\u003c\/li\u003e\n\u003cli\u003eC35 Soft Carrying Case\u003c\/li\u003e\n\u003cli\u003e9V battery (installed)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_87-V_Spec.PDF?1861\" target=\"_blank\" title=\"Fluke 87 V Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 87 V Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-02-26T16:52:20", "created_at":"2018-02-27T09:12:23", "vendor":"Fluke", "type":"Multimeters", "tags":[], "price":100015, "price_min":100015, "price_max":100015, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[10852425924651], "variants":[{ "id":10852425924651, "product_id":1054037278763, "product_handle":"fluke-87v-e2-industrial-electrician-combo-kit", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"FLU-87-5\/E2-KIT-CUSTOM", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 87V\/E2 Industrial Electrician Combo Kit - Default Title", "options":["Default Title"], "price":100015, "weight":2268, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969353212"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke87-5E2_KIT_Main.jpg?v=1519747945","\/\/kingswayinstruments.com\/cdn\/shop\/products\/61gS4-3-8yL._SL1200.jpg?v=1519747946","\/\/kingswayinstruments.com\/cdn\/shop\/products\/4EB19_AS01.jpg?v=1519747946"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke87-5E2_KIT_Main.jpg?v=1519747945", "options":["Title"], "url":"\/products\/fluke-87v-e2-industrial-electrician-combo-kit"}
Fluke 87V/E2 Industrial Electrician Combo Kit
Product Description
Ideal for electricians, this combo kit is built around the Fluke 87V, the most widely used industrial digital multimeter in the world and includes essential accessories to make you even more productive. This kit offers 15% savings compared with the individual price of all the accessories. Plus you'll be working with the most trusted tools in the world.
Sku: FLU-87-5/E2-KIT-CUSTOM
Vendor: Fluke
On Back-Order
Overview
Key features
All functionality of the 87V Industrial Digital Multimeter, plus:
- Fully insulated 3 mm exposed metal test probes for electricians working in high energy environments
- C35 Soft Carrying Case holds meter, test leads and other accessories
- TPAK magnetic hanging strap lets you attach the meter to any ferrous surface, such as cabinets and iron pipes.
Specifications
Specifications | ||
Voltage DC | Maximum Voltage | 1000 V |
Accuracy | ±(0.05% + 1) | |
Maximum Resolution | 10 µV | |
Voltage AC | Maximum Voltage | 1000 V |
Accuracy | ±(0.7% + 2) True RMS | |
AC Bandwidth | 20 kHz with low pass filter; 3 db @ 1 kHz | |
Maximum Resolution | 0.1 mV | |
Current DC | Maximum Amps | 10 A (20 A for 30 seconds maximum) |
Amps Accuracy | ±(0.2% + 2) | |
Maximum Resolution | 0.01 µA | |
Current AC | Maximum Amps | 10 A (20 A for 30 seconds maximum) |
Amps Accuracy | ±(1.0% + 2) True RMS | |
Maximum Resolution | 0.1 µA | |
Resistance | Maximum Resistance | 50 MΩ |
Accuracy | ±(0.2% + 1) | |
Maximum Resolution | 0.1Ω | |
Capacitance | Maximum Capacitance | 9,999 µF |
Accuracy | ±(1% + 2) | |
Maximum Resolution | 0.01 nF | |
Frequency | Maximum Frequency | 200 kHz |
Accuracy | ±(0.005% + 1) | |
Maximum Resolution | 0.01 Hz | |
Duty Cycle | Maximum Duty Cycle | 99.9% |
Accuracy | ±(0.2% per khz +0.1%) | |
Maximum Resolution | 0.1% | |
Temperature Measurement | -200.0°C - 1090°C -328.0°F - 1994.0°F excluding probe |
|
80 BK Temperature Probe | -40.0°C - 260°C -40.0°F - 500°F, 2.2°C or 2% whichever is greater |
|
Conductance | Maximum Conductance | 60.00 nS |
Accuracy | ±(1.0% + 10) | |
Maximum Resolution | 0.01 nS | |
Diode | Range | 3 V |
Resolution | 1 mV | |
Accuracy | ±(2% + 1) | |
Duty Cycle Range | Accuracy | Within ±(02% per kHz +0.1%) |
Environmental Specifications | ||
Operating Temperature | -20°C to +55°C | |
Storage Temperature | -40°C to +60°C | |
Humidity (Without Condensation) | 0% - 90% (0°C - 35°C) 0% - 70% (35°C - 55°C) |
|
Operating Altitude | 2000 m | |
Safety Specifications | ||
Overvoltage category | EN 61010-1 to 1000 V CAT III, 600V CAT IV | |
Agency Approvals | UL, CSA, TÜV, VDE listed | |
Mechanical and General Specifications | ||
Size | 201 x 98 x 52 mm (with holster) | |
Weight | 355 g 624 g - with holster |
|
Display | Digital | 6000 counts updates 4/sec. 19,999 counts in high-resolution mode |
Analog | 32 segments, updates 40/sec. | |
Frequency | 19,999 counts, updates 3/sec at > 10 Hz | |
Warranty | Lifetime | |
Battery Life | Alkaline | ~400 hours typical, without backlight |
Shock | 1 Meter drop per IEC 61010-1:2001 | |
Vibration | Per MIL-PRF-28800 for a Class 2 instrument |
What's in the Box
Includes:
- 87V Industrial Multimeter
- TL224 SureGrip™ Insulated Test Leads
- AC220 SureGrip™ Alligator Clips
- TL238 SureGrip™ Test Probes
- ToolPak™ Magnetic Meter Hanging Kit
- 80BK-A DMM Temperature Probe
- C35 Soft Carrying Case
- 9V battery (installed)
Resources
Related Products
Fluke iSee Thermal Imager Attachment TC01A/TC01B
$679.99 CAD
Fluke 302+ AC Clamp Meter 600V, 400A (Average Responding)
$176.00 CAD $234.00 CAD
Fluke 17B+ Digital Multimeter with Temperature (Average Responding)
$225.00 CAD $323.00 CAD
Fluke 15B+ Digital Multimeter (Average Responding)
$175.00 CAD $224.00 CAD
Fluke 9009 Dual Dry Block Temperature Calibrator
$11,536.88 CAD
Fluke IRR1-SOL Solar Irradiance Meter
$571.28 CAD
Fluke 417D Laser Distance Meter
$201.27 CAD
Fluke 1770 Series Three-Phase Power Quality Analyzers
From $11,527.35 CAD
Fluke 190 Series III ScopeMeters®