Fluke T6-1000/PRV240FS Electrical Tester with Proving Unit
Product Description
Fluke Electrical Tester with FieldSense Plus PRV240FS Proving Unit, 1000V AC/DC, 100A AC
Measure voltage to 1000 V ac through the open fork, without test leads
Overview
Measure voltage up to 1000 V ac due to FieldSense technology, which easily and quickly takes measurements by sliding a conductor through the open fork. Additionally, without opening covers or removing wire nuts, on wires up to AWG 4/0 (120 mm2), carrying as much as 200 A which makes the jobs safer, faster and easier.
Features
- FieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage
- Simultaneous voltage and current display shows all power supply measurements at a glance for efficient troubleshooting
- 1 to 1000 V ac or dc
- 0.1 to 200 A ac
- Resistance 1 Ω to 100 kΩ
- Frequency measurement 45 to 66 Hz
- Works with wires up to AWG 4/0 (120 mm2) with a 0.7" (17.8 mm) jaw opening
- Hold button temporarily freezes the reading for easy viewing
- Easy to read display with backlight
Fluke PRV240FS Proving Unit
Reduces the need for personal protective equipment (PPE) when a known voltage source is not available for verification (PPE is still needed for absence of voltage testing when appropriate).
Features
- Sources both ac and dc steady-state voltage - supplies 240 V dc/ac
- A single LED indicates functionality, making this unit a simple-to-use solution for verification of your test tool
- Compatible with both high impedance or low impedance multimeters, clamp meters or two pole testers
- Voltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact
- Long battery life - 5000 tests per set of four AA batteries
Specifications
Fluke T6-1000/PRV240FS Specifications
FieldSense AC Voltage True RMS | |
Requires Test Leads | No |
Range | 1000 V |
Resolution | 1 V |
Accuracy | ±(3% + 3 counts) 45 to 66 Hz |
FieldSense AC Current True RMS | |
Requires Test Leads | No |
Range | 200.0 A |
Resolution | 0.1 A |
Accuracy | ±(3% + 3 counts) 45 to 66 Hz |
FieldSense Frequency (Hz) | |
Requires Test Leads | No |
Range | 45 to 66 Hz |
Resolution | 1 Hz |
Accuracy | ±(1% + 2 counts) |
Volts AC True RMS | |
Requires Test Leads | Yes |
Range | 1000 V |
Resolution | 1 V |
Accuracy | ±(1.5% + 2 counts) 45 to 66 Hz |
Volts DC | |
Requires Test Leads | Yes |
Range | 1000 V |
Resolution | 1 V |
Accuracy | ±(1% + 2 counts) |
Resistance | |
Requires Test Leads | Yes |
Range | 1000 V 2000 Ω 20 kΩ 100 kΩ |
Resolution | 1 V 1 Ω 0.01 kΩ 0.1 kΩ |
Accuracy | ±(1% + 2 counts) |
Safety | |
Range | 1000 V CAT III 600 V CAT IV |
General Specifications | |
Calibration | One year calibration cycle |
Jaw Opening | 0.7" (17.8 mm) |
Operating Temperature | 14 to 122°F (-10 to 50°C) |
Storage Temperature | -22 to 140°F (-30 to 60°C) |
Operating Altitude | 6562' (2000 m) |
Storage Altitude | 32,808' (10,000 m) |
Relative Humidity | 0 to 90%, 41 to 86°F (5 to 30°C) 0 to 75%, 86 to 104°F (30 to 40°C) 0 to 45%, 104 to 122°F (40 to 50°C) |
Battery Type and Life | 2 x AA (IEC LR6) 360 hours continuous Typical; 200 hours using FieldSense |
Temperature Coefficient | 0.1 x (specified accuracy) /°C for <18 or >28°C |
Safety | IEC/EN 61010-1: Pollution degree 2 |
Electromagnetic Environment | IEC/EN 61326-1: Portable |
Dimensions | 2.4 x 10.2 x 1.7" (61.1 x 259.3 x 43.8 mm) |
Weight | 0.78 lb (350 g) |
What's in the Box
- T6-1000 Electrical Teste
- PRV240FS Proving Unit
- Attached Test Leads, with 0.16" (4 mm) Removable Probe Caps
- User's Manual