{ "id":1858235564075, "title":"Fluke T6-1000\/PRV240FS Electrical Tester with Proving Unit","handle":"fluke-t6-1000-prv240fs-electrical-tester-with-proving-unit", "description":"\u003cp\u003eFluke Electrical Tester with FieldSense Plus PRV240FS Proving Unit, 1000V AC\/DC, 100A AC\u003cbr\u003eMeasure voltage to 1000 V ac through the open fork, without test leads\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eMeasure voltage up to 1000 V ac due to FieldSense technology, which easily and quickly takes measurements by sliding a conductor through the open fork. Additionally, without opening covers or removing wire nuts, on wires up to AWG 4\/0 (120 mm2), carrying as much as 200 A which makes the jobs safer, faster and easier.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage\u003c\/li\u003e\n\u003cli\u003eSimultaneous voltage and current display shows all power supply measurements at a glance for efficient troubleshooting\u003c\/li\u003e\n\u003cli\u003e1 to 1000 V ac or dc\u003c\/li\u003e\n\u003cli\u003e0.1 to 200 A ac\u003c\/li\u003e\n\u003cli\u003eResistance 1 Ω to 100 kΩ\u003c\/li\u003e\n\u003cli\u003eFrequency measurement 45 to 66 Hz\u003c\/li\u003e\n\u003cli\u003eWorks with wires up to AWG 4\/0 (120 mm2) with a 0.7\" (17.8 mm) jaw opening\u003c\/li\u003e\n\u003cli\u003eHold button temporarily freezes the reading for easy viewing\u003c\/li\u003e\n\u003cli\u003eEasy to read display with backlight\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke PRV240FS Proving Unit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReduces the need for personal protective equipment (PPE) when a known voltage source is not available for verification (PPE is still needed for absence of voltage testing when appropriate).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003eSources both ac and dc steady-state voltage - supplies 240 V dc\/ac\u003c\/li\u003e\n\u003cli\u003eA single LED indicates functionality, making this unit a simple-to-use solution for verification of your test tool\u003c\/li\u003e\n\u003cli\u003eCompatible with both high impedance or low impedance multimeters, clamp meters or two pole testers\u003c\/li\u003e\n\u003cli\u003eVoltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact\u003c\/li\u003e\n\u003cli\u003eLong battery life - 5000 tests per set of four AA batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ch4\u003eFluke T6-1000\/PRV240FS Specifications\u003c\/h4\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFieldSense AC Voltage True RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(3% + 3 counts) 45 to 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFieldSense AC Current True RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e200.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(3% + 3 counts) 45 to 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFieldSense Frequency (Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e45 to 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVolts AC True RMS\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 2 counts) 45 to 66 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eVolts DC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequires Test Leads\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V\u003cbr\u003e2000 Ω\u003cbr\u003e20 kΩ\u003cbr\u003e100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 V\u003cbr\u003e1 Ω\u003cbr\u003e0.01 kΩ\u003cbr\u003e0.1 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1% + 2 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e1000 V CAT III\u003cbr\u003e600 V CAT IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003eOne year calibration cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd\u003e0.7\" (17.8 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e14 to 122°F (-10 to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-22 to 140°F (-30 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e6562' (2000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Altitude\u003c\/td\u003e\n\u003ctd\u003e32,808' (10,000 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0 to 90%, 41 to 86°F (5 to 30°C)\u003cbr\u003e0 to 75%, 86 to 104°F (30 to 40°C)\u003cbr\u003e0 to 45%, 104 to 122°F (40 to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type and Life\u003c\/td\u003e\n\u003ctd\u003e2 x AA (IEC LR6)\u003cbr\u003e360 hours continuous\u003cbr\u003eTypical; 200 hours using FieldSense\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.1 x (specified accuracy) \/°C for \u0026lt;18 or \u0026gt;28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61010-1: Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic Environment\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61326-1: Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.4 x 10.2 x 1.7\" (61.1 x 259.3 x 43.8 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.78 lb (350 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eT6-1000 Electrical Teste\u003c\/li\u003e\n\u003cli\u003ePRV240FS Proving Unit\u003c\/li\u003e\n\u003cli\u003eAttached Test Leads, with 0.16\" (4 mm) Removable Probe Caps\u003c\/li\u003e\n\u003cli\u003eUser's Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e", "published_at":"2019-08-16T10:18:39", "created_at":"2019-08-16T10:24:07", "vendor":"Fluke", "type":"Multimeters", "tags":[], "price":74799, "price_min":74799, "price_max":74799, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[16996849385515], "variants":[{ "id":16996849385515, "product_id":1858235564075, "product_handle":"fluke-t6-1000-prv240fs-electrical-tester-with-proving-unit", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"FLU-T6-1000\/PRV240FS", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke T6-1000\/PRV240FS Electrical Tester with Proving Unit - Default Title", "options":["Default Title"], "price":74799, "weight":907, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969854177"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/T6-1000-PRV240FS.jpg?v=1565972650"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/T6-1000-PRV240FS.jpg?v=1565972650", "options":["Title"], "url":"\/products\/fluke-t6-1000-prv240fs-electrical-tester-with-proving-unit"}

Fluke T6-1000/PRV240FS Electrical Tester with Proving Unit

Product Description

Fluke Electrical Tester with FieldSense Plus PRV240FS Proving Unit, 1000V AC/DC, 100A AC
Measure voltage to 1000 V ac through the open fork, without test leads

Sku: FLU-T6-1000/PRV240FS
Vendor: Fluke
On Back-Order
$747.99 CAD

Measure voltage up to 1000 V ac due to FieldSense technology, which easily and quickly takes measurements by sliding a conductor through the open fork. Additionally, without opening covers or removing wire nuts, on wires up to AWG 4/0 (120 mm2), carrying as much as 200 A which makes the jobs safer, faster and easier.

Features

  • FieldSense technology for ac voltage, current and frequency measurement without making electrical contact to live voltage
  • Simultaneous voltage and current display shows all power supply measurements at a glance for efficient troubleshooting
  • 1 to 1000 V ac or dc
  • 0.1 to 200 A ac
  • Resistance 1 Ω to 100 kΩ
  • Frequency measurement 45 to 66 Hz
  • Works with wires up to AWG 4/0 (120 mm2) with a 0.7" (17.8 mm) jaw opening
  • Hold button temporarily freezes the reading for easy viewing
  • Easy to read display with backlight

Fluke PRV240FS Proving Unit

Reduces the need for personal protective equipment (PPE) when a known voltage source is not available for verification (PPE is still needed for absence of voltage testing when appropriate).

Features

    • Sources both ac and dc steady-state voltage - supplies 240 V dc/ac
    • A single LED indicates functionality, making this unit a simple-to-use solution for verification of your test tool
    • Compatible with both high impedance or low impedance multimeters, clamp meters or two pole testers
    • Voltage is sourced through recessed contacts that are activated when tested probes are inserted to avoid accidental contact
    • Long battery life - 5000 tests per set of four AA batteries

Fluke T6-1000/PRV240FS Specifications

FieldSense AC Voltage True RMS
Requires Test Leads No
Range 1000 V
Resolution 1 V
Accuracy ±(3% + 3 counts) 45 to 66 Hz
FieldSense AC Current True RMS
Requires Test Leads No
Range 200.0 A
Resolution 0.1 A
Accuracy ±(3% + 3 counts) 45 to 66 Hz
FieldSense Frequency (Hz)
Requires Test Leads No
Range 45 to 66 Hz
Resolution 1 Hz
Accuracy ±(1% + 2 counts)
Volts AC True RMS
Requires Test Leads Yes
Range 1000 V
Resolution 1 V
Accuracy ±(1.5% + 2 counts) 45 to 66 Hz
Volts DC
Requires Test Leads Yes
Range 1000 V
Resolution 1 V
Accuracy ±(1% + 2 counts)
Resistance
Requires Test Leads Yes
Range 1000 V
2000 Ω
20 kΩ
100 kΩ
Resolution 1 V
1 Ω
0.01 kΩ
0.1 kΩ
Accuracy ±(1% + 2 counts)
Safety
Range 1000 V CAT III
600 V CAT IV
General Specifications
Calibration One year calibration cycle
Jaw Opening 0.7" (17.8 mm)
Operating Temperature 14 to 122°F (-10 to 50°C)
Storage Temperature -22 to 140°F (-30 to 60°C)
Operating Altitude 6562' (2000 m)
Storage Altitude 32,808' (10,000 m)
Relative Humidity 0 to 90%, 41 to 86°F (5 to 30°C)
0 to 75%, 86 to 104°F (30 to 40°C)
0 to 45%, 104 to 122°F (40 to 50°C)
Battery Type and Life 2 x AA (IEC LR6)
360 hours continuous
Typical; 200 hours using FieldSense
Temperature Coefficient 0.1 x (specified accuracy) /°C for <18 or >28°C
Safety IEC/EN 61010-1: Pollution degree 2
Electromagnetic Environment IEC/EN 61326-1: Portable
Dimensions 2.4 x 10.2 x 1.7" (61.1 x 259.3 x 43.8 mm)
Weight 0.78 lb (350 g)


  • T6-1000 Electrical Teste
  • PRV240FS Proving Unit
  • Attached Test Leads, with 0.16" (4 mm) Removable Probe Caps
  • User's Manual

Related Products