{ "id":1250168012843, "title":"Fluke 772 Milliamp Process Clamp Meter","handle":"fluke-772-milliamp-process-clamp-meter", "description":"\u003cp\u003e\u003cstrong\u003eFluke 772 Milliamp Clamp Meter measures, sources, and simulates 4-20 mA signals for testing control system I\/O or IPs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 772 adds to the basic capabilities of the Fluke 771 to save more time and expand its applications. With the 771, you'll also be able to: source and simulate 4-20 mA signals for testing control system I\/O; measure 4-20 mA signals with in-circuit measurement; power a transmitter with the 24 V loop power supply; and automatically ramp and step change the 4-20 mA output for remote testing.\u003c\/p\u003e\n\u003cp\u003eYou'll be able to test 4–20 mA signals five times faster than with traditional DMMs, and without breaking the loop. That means you can troubleshoot a live device without having to power down, which can save you time, and help you avoid possibly missing something going on in the process.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eLoop calibrator that measures 4 to 20 mA signals without breaking the loop\u003c\/li\u003e\n\u003cli\u003eFeatures best in class 0.2% accuracy\u003c\/li\u003e\n\u003cli\u003eSimultaneously measures the mA signal with the clamp and sources a mA signal\u003c\/li\u003e\n\u003cli\u003eDelivers 0.01 mA resolution and sensitivity\u003c\/li\u003e\n\u003cli\u003eMeasures mA signals for PLC and control system analog I\/O\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"35%\"\u003eDiameter of measurable conductor\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.177” or 4.5 mm max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10 to 50ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-25 to 60ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt; 90% @ \u0026lt;30ºC, \u0026lt; 75% @ 30 to 55ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e44 x 70 x 246 mm (2 7\/8 x 5 ¾ x 11 5\/8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e410 g, (14.4 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom 2 g, 5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 meter drop test (except the jaw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eEMI\/RFI\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMeets EN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"2\"\u003eFor current measurement w\/ JAW, add 1mA to specification for EMC field strengths of 1V\/m up to 3V\/m.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01% ºC\u003cbr\u003e(\u0026lt; 18ºC or \u0026gt; 28ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower, battery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e(4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree years for electronics\u003cbr\u003eOne year for cable and clamp assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"4\"\u003eFunctional Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" width=\"35%\"\u003emA measurement\u003cbr\u003e(measured by clamp)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 20.99 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \/ range\u003c\/td\u003e\n\u003ctd\u003e21.0mA to 100.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% + 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA measurement (measured in series with test jacks)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 24.00 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA source (maximum mA drive: 24 mA into 1,000 ohms)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 24.00 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA simulate (maximum voltage 50 V dc)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 24.00 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFour AA alkaline batteries (installed)\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eTL75 test leads\u003c\/li\u003e\n\u003cli\u003eAC 72 detachable clip\u003c\/li\u003e\n\u003cli\u003eTL 940 mini hook test leads\u003c\/li\u003e\n\u003cli\u003eInstruction sheet\u003c\/li\u003e\n\u003cli\u003eHanging tool with hook and loop strap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_772-773_Spec_Sheet.pdf?1856\" target=\"_blank\" title=\"Fluke 772 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 772 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-05-09T14:03:14", "created_at":"2018-05-09T14:07:48", "vendor":"Fluke", "type":"Calibrators", "tags":[], "price":196111, "price_min":196111, "price_max":196111, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[12025129271339], "variants":[{ "id":12025129271339, "product_id":1250168012843, "product_handle":"fluke-772-milliamp-process-clamp-meter", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"FLU-772", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 772 Milliamp Process Clamp Meter - Default Title", "options":["Default Title"], "price":196111, "weight":2268, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969475815"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/772-01b-600x402.jpg?v=1525896470"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/772-01b-600x402.jpg?v=1525896470", "options":["Title"], "url":"\/products\/fluke-772-milliamp-process-clamp-meter"}

Fluke 772 Milliamp Process Clamp Meter

Product Description

Fluke 772 Milliamp Clamp Meter measures, sources, and simulates 4-20 mA signals for testing control system I/O or IPs

The Fluke 772 adds to the basic capabilities of the Fluke 771 to save more time and expand its applications. With the 771, you'll also be able to: source and simulate 4-20 mA signals for testing control system I/O; measure 4-20 mA signals with in-circuit measurement; power a transmitter with the 24 V loop power supply; and automatically ramp and step change the 4-20 mA output for remote testing.

You'll be able to test 4–20 mA signals five times faster than with traditional DMMs, and without breaking the loop. That means you can troubleshoot a live device without having to power down, which can save you time, and help you avoid possibly missing something going on in the process.

Sku: FLU-772
Vendor: Fluke
On Back-Order
$1,961.11 CAD

Key features

  • Loop calibrator that measures 4 to 20 mA signals without breaking the loop
  • Features best in class 0.2% accuracy
  • Simultaneously measures the mA signal with the clamp and sources a mA signal
  • Delivers 0.01 mA resolution and sensitivity
  • Measures mA signals for PLC and control system analog I/O
Specifications
Diameter of measurable conductor 0.177” or 4.5 mm max
Operating temperature -10 to 50ºC
Storage temperature -25 to 60ºC
Operating humidity < 90% @ <30ºC, < 75% @ 30 to 55ºC
Operating altitude 0 to 2000 m
IP rating IP 40
Size 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in)
Weight 410 g, (14.4 oz)
Vibration Random 2 g, 5 to 500 Hz
Shock 1 meter drop test (except the jaw)
EMI/RFI Meets EN61326-1
For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m.
Temperature coefficient 0.01% ºC
(< 18ºC or > 28ºC)
Power, battery life (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms
Warranty Three years for electronics
One year for cable and clamp assembly
Functional Specifications
mA measurement
(measured by clamp)
Resolution / range 0 to 20.99 mA
Accuracy 0.2% + 5 counts
Resolution / range 21.0mA to 100.0 mA
Accuracy 1% + 5 counts
mA measurement (measured in series with test jacks) Resolution / range 0 to 24.00 mA
Accuracy 0.2% + 2 counts
mA source (maximum mA drive: 24 mA into 1,000 ohms) Resolution / range 0 to 24.00 mA
Accuracy 0.2% + 2 counts
mA simulate (maximum voltage 50 V dc) Resolution / range 0 to 24.00 mA
Accuracy 0.2% + 2 counts


Includes:

  • Four AA alkaline batteries (installed)
  • Soft carrying case
  • TL75 test leads
  • AC 72 detachable clip
  • TL 940 mini hook test leads
  • Instruction sheet