{ "id":1262436483115, "title":"Fluke 773 Milliamp Process Clamp Meter","handle":"fluke-773-milliamp-process-clamp-meter", "description":"\u003cp\u003e\u003cstrong\u003eFluke 773 Milliamp Process Clamp Meter saves time and money by measuring output signals without shutting down the system\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 773 milliamp clamp meter is accurate and versatile. It saves time and money by measuring 4–20 mA signals five times faster than with traditional DMMs, and without breaking the loop. That means you can troubleshoot a live device without having to power down and possibly miss something going on in the process.\u003c\/p\u003e\n\u003cp\u003eThe 773 is ideal for troubleshooting transmitters, valves, and programmable logic controllers (PLCs) found in process plants. It measures low level dc current and correlates process indication with a real physical value. And it measures up to 99.0 mA non-contact, including 10 to 50 mA signals in older control systems.\u003c\/p\u003e\n\u003cp\u003eThe 773 also sources and measures dc voltage, so it can be used to troubleshoot voltage input and output devices. You can detach the clamp section of the meter and use it as a remote jaw, connected to the main body by an extension cable to make it easier to take measurements in tight spaces. Plus, automatic power-off features save battery life so you can work longer without changing the batteries.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch2 class=\"features-title\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv id=\"keyfeature_content\"\u003e\n\u003cul\u003e\n\u003cli\u003eLoop calibrator that measures 4 to 20 mA signals without breaking the loop\u003c\/li\u003e\n\u003cli\u003eFeatures best in class 0.2% accuracy\u003c\/li\u003e\n\u003cli\u003eSources 4 to 20 mA signals for testing control system I\/O or I\/Ps\u003c\/li\u003e\n\u003cli\u003eDelivers 0.01 mA resolution and sensitivity\u003c\/li\u003e\n\u003cli\u003eMeasures DC voltage to verify 24V power supplies or voltage I\/O signals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"35%\"\u003eDiameter of measurable conductor\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.177\" or 4.5 mm max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10 to 50ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-25 to 60ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt; 90% @ \u0026lt;30ºC, \u0026lt; 75% @ 30 to 55ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e44 x 70 x 246 mm (2 7\/8 x 5 ¾ x 11 5\/8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e410 g, (14.4 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom 2 g, 5 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 meter drop test (except the jaw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eEMI\/RFI\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMeets EN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"small-font nobold\" colspan=\"2\"\u003eFor current measurement w\/ JAW, add 1mA to specification for EMC field strengths of 1V\/m up to 3V\/m.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01% ºC\u003cbr\u003e(\u0026lt; 18ºC or \u0026gt; 28ºC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower, battery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e(4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eThree years for electronics\u003cbr\u003eOne year for cable and clamp assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eFunctional Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" width=\"25%\"\u003emA measurement\u003cbr\u003e(measured by clamp)\u003c\/td\u003e\n\u003ctd width=\"25%\"\u003e\u003cb\u003eResolution \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd width=\"50%\"\u003e0 to 20.99 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution \/ range\u003c\/td\u003e\n\u003ctd\u003e21.0mA to 100.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1% + 5 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA measurement (measured in series with test jacks)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 24.00 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA source (maximum mA drive: 24 mA into 1,000 ohms)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 24.00 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003emA simulate (maximum voltage 50 V dc)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 24.00 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVoltage source (2 mA maximum drive current)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 10.00 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVoltage measure\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution \/ range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 30.00 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFour AA alkaline batteries (installed)\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eTL75 test leads\u003c\/li\u003e\n\u003cli\u003eAC 72 detachable clip\u003c\/li\u003e\n\u003cli\u003eTL 940 mini hook test leads\u003c\/li\u003e\n\u003cli\u003eInstruction sheet\u003c\/li\u003e\n\u003cli\u003eHanging tool with hook and loop strap\u003c\/li\u003e\n\u003cli\u003eFluke 773 Milliamp Process Clamp Meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_772-773_Spec_Sheet.pdf?1856\" target=\"_blank\" title=\"Fluke 773 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 773 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-05-15T17:15:13", "created_at":"2018-05-16T09:00:10", "vendor":"Fluke", "type":"Calibrators", "tags":[], "price":249015, "price_min":249015, "price_max":249015, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[12139027169323], "variants":[{ "id":12139027169323, "product_id":1262436483115, "product_handle":"fluke-773-milliamp-process-clamp-meter", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"FLU-773", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 773 Milliamp Process Clamp Meter - Default Title", "options":["Default Title"], "price":249015, "weight":2268, "compare_at_price":null, "inventory_quantity":4, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":4, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969475822"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-773-2dc.jpg?v=1526482812"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-773-2dc.jpg?v=1526482812", "options":["Title"], "url":"\/products\/fluke-773-milliamp-process-clamp-meter"}

Fluke 773 Milliamp Process Clamp Meter

Product Description

Fluke 773 Milliamp Process Clamp Meter saves time and money by measuring output signals without shutting down the system

The Fluke 773 milliamp clamp meter is accurate and versatile. It saves time and money by measuring 4–20 mA signals five times faster than with traditional DMMs, and without breaking the loop. That means you can troubleshoot a live device without having to power down and possibly miss something going on in the process.

The 773 is ideal for troubleshooting transmitters, valves, and programmable logic controllers (PLCs) found in process plants. It measures low level dc current and correlates process indication with a real physical value. And it measures up to 99.0 mA non-contact, including 10 to 50 mA signals in older control systems.

The 773 also sources and measures dc voltage, so it can be used to troubleshoot voltage input and output devices. You can detach the clamp section of the meter and use it as a remote jaw, connected to the main body by an extension cable to make it easier to take measurements in tight spaces. Plus, automatic power-off features save battery life so you can work longer without changing the batteries.

Sku: FLU-773
Vendor: Fluke
4 left in stock.
$2,490.15 CAD
Maximum quantity available reached.

Key features

  • Loop calibrator that measures 4 to 20 mA signals without breaking the loop
  • Features best in class 0.2% accuracy
  • Sources 4 to 20 mA signals for testing control system I/O or I/Ps
  • Delivers 0.01 mA resolution and sensitivity
  • Measures DC voltage to verify 24V power supplies or voltage I/O signals
Specifications
Diameter of measurable conductor 0.177" or 4.5 mm max
Operating temperature -10 to 50ºC
Storage temperature -25 to 60ºC
Operating humidity < 90% @ <30ºC, < 75% @ 30 to 55ºC
Operating altitude 0 to 2000 m
IP rating IP 40
Size 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in)
Weight 410 g, (14.4 oz)
Vibration Random 2 g, 5 to 500 Hz
Shock 1 meter drop test (except the jaw)
EMI/RFI Meets EN61326-1
For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m.
Temperature coefficient 0.01% ºC
(< 18ºC or > 28ºC)
Power, battery life (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms
Warranty Three years for electronics
One year for cable and clamp assembly
Functional Specifications
mA measurement
(measured by clamp)
Resolution / range 0 to 20.99 mA
Accuracy 0.2% + 5 counts
Resolution / range 21.0mA to 100.0 mA
Accuracy 1% + 5 counts
mA measurement (measured in series with test jacks) Resolution / range 0 to 24.00 mA
Accuracy 0.2% + 2 counts
mA source (maximum mA drive: 24 mA into 1,000 ohms) Resolution / range 0 to 24.00 mA
Accuracy 0.2% + 2 counts
mA simulate (maximum voltage 50 V dc) Resolution / range 0 to 24.00 mA
Accuracy 0.2% + 2 counts
Voltage source (2 mA maximum drive current) Resolution / range 0 to 10.00 V DC
Accuracy 0.2% + 2 counts
Voltage measure Resolution / range 0 to 30.00 V DC
Accuracy 0.2% + 2 counts


Includes:

  • Four AA alkaline batteries (installed)
  • Soft carrying case
  • TL75 test leads
  • AC 72 detachable clip
  • TL 940 mini hook test leads
  • Instruction sheet
  • Hanging tool with hook and loop strap
  • Fluke 773 Milliamp Process Clamp Meter