Megger MIT1025/2 10kV Advanced Insulation Tester
Product Description
The Megger range of insulation testers are known worldwide for their rugged dependability, long service life, and accurate, reliable measurements. The Advanced models are an ideal choice if you need to record test results, transfer results to software/mobile app (via USB or Bluetooth LE), and want the benefits of more diagnostic insulation testing. The Advanced range also adds additional noise immunity for power distribution environments, and the ability to either increase or decrease the output current.
Overview
Features
- RE>Act mode not only measures reabsorption current but also provides an indication to the user of the impact it will have on measurement range and accuracy
- RE>Act removes the possibility to pass insulation that should have been failed, and it can also be used to monitor discharge following a test
- Preconfigured diagnostic tests include:
- Polarisation Index (PI)
- Dielectric Absorption Ratio (DAR)
- Dielectric Discharge (DD)
- Polarisation Depolarisation Current (PDC)
- Stepped Voltage (SV)
- Ramp test
- PI predictor function (PIp) uses the first part of the IR curve to predict the rest at 5 minutes into the test
- Preset voltage ranges are provided in insulation test mode
- Measures up to 20 TΩ
- Up to 6 mA noise rejection
Applications
- Electrical contractors
- Testing and service companies
- Wind farm and solar generation operators
- Power generation and distribution companies
- Industrial companies
- Rail companies
- Acceptance testing at installation to check conformance to specifications
- Routine preventive/predictive maintenance testing after installation
- QA testing as part of the manufacturing process
- Diagnostic testing to isolate faulty components for repair
Specifications
Test Voltages | 500 V, 1000 V, 2500 V, 5000 V, 10,000 V, or User-defined |
Test Voltage Accuracy | +4%, -0%, ±10 V nominal at 1 GΩ load 32 to 86°F (0 to 30°C ) |
Resistance Range | 10 kΩ to 20 TΩ at 10 kV |
Resistance Accuracy | ±5%: 2 TΩ at 10 kV, 1 TΩ at 5 kV, 500 GΩ at 2500 V, 200 GΩ at 1000 V, 100 GΩ at 500 V ±20%: 20 TΩ at 10 kV, 10 TΩ at 5 kV, 5 TΩ at 2500 V, 2 TΩ at 1000 V, 1 TΩ at 500 V |
Capacitance Range | 10 nF to 25 μF |
Capacitance Accuracy | ±10% ±5 nF |
Current Range | 0.01 nA to 6 mA |
Current Accuracy | ±5% ±0.2 nA at all voltages |
Interference Rejection | 6 mA from 960 V to 10 kV |
Voltmeter Range | 30 V to 660 V AC/DC, 45 Hz to 65 Hz |
Voltmeter Accuracy | ±3%, ±3 V |
Guard Terminal Performance | Guards out current IG ≥5000× IL at 100 GΩ / 5000 V with maximum error of 1% |
Analogue Display Range | 100 kΩ to 10 TΩ |
Digital Display Range | 10 kΩ to 20 TΩ |
Short Circuit / Charge Current | 1 mA, 3 mA Default, 6 mA at 5 kV, 10 kV, 15 kV (6 mA only from mains supply) |
Insulation Test Alarm | 100 kΩ to 10 GΩ |
Capacitor Charge Time | <5 s/μF at 3 mA to 10 kV |
Capacitor Discharge Time | <250 ms/μF to discharge from 10 kV to 50 V |
Auto-Ranging AC Voltage | 90 to 264 V rms 47 to 63 Hz 100 VA |
Battery Charge Time | 2.5 hours (deep discharge) 2 hours (normal discharge) |
Battery Voltage | 10.8 V, 5.2 Ah Li-ion Meets IEC 62133:2003 |
Battery Life | 4.5 hours (typical) continuous testing at 10 kV with a 100 MΩ load |
Timer Range | Up to 99 minutes 59 seconds (15 seconds minimum setting) |
Test Modes | IR, IR(t), DAR, PI, SV, DD, PDC, Ramp test |
Memory Capacity | 5.5 hours logging at 5 second intervals |
What's in the Box
- Insulation Resistance Tester
- Quick Start label
- Power lead
- Screened USB cable with filters
- Lead set 3 kV, 9 x 9' (3 x 3 m) with medium clips
- Lead set HV, 9 x 9' (3 x 3 m) with medium and large clips