Amprobe LCR55A Capacitance Tester

Insulation Testers

$535.83 CAD
{"id":1289610625067,"title":"Amprobe LCR55A Capacitance Tester","handle":"amprobe-lcr55a-capacitance-tester","description":"The ultimate electronic component verifier measures inductance, capacitance, resistance, transistors, diodes and microwave diodes.","published_at":"2018-05-29T15:28:21-06:00","created_at":"2018-05-29T15:41:07-06:00","vendor":"Amprobe","type":"Insulation Testers","tags":[],"price":53583,"price_min":53583,"price_max":53583,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12314166165547,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"Amprobe LCR55A","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Amprobe LCR55A Capacitance Tester","public_title":null,"options":["Default Title"],"price":53583,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969414753","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/1YBT6_AS01.jpg?v=1527630069"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/1YBT6_AS01.jpg?v=1527630069","options":["Title"],"media":[{"alt":null,"id":1687382130731,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/1YBT6_AS01.jpg?v=1527630069"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/1YBT6_AS01.jpg?v=1527630069","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"The ultimate electronic component verifier measures inductance, capacitance, resistance, transistors, diodes and microwave diodes."}
Amprobe LCR55A Capacitance Tester

Amprobe LCR55A Capacitance Tester

$535.83 CAD

The ultimate electronic component verifier measures inductance, capacitance, resistance, transistors, diodes and microwave diodes.


More Info
Megger MIT515 5kV Insulation Tester

Insulation Testers

$6,170.00 CAD
{"id":1263017984043,"title":"Megger MIT515 5kV Insulation Tester","handle":"megger-mit515-5kv-insulation-tester","description":"\u003cp\u003eThe MIT515 is the simplest of Megger's new range of small light 5 kV insulation resistance testers for the testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustry best guard terminal accuracy\u003c\/li\u003e\n\u003cli\u003eSmaller size and lightweight allows easier transport and use without compromising performance\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight for easy transport and use\u003c\/li\u003e\n\u003cli\u003eAuto IR, DAR and PI\u003c\/li\u003e\n\u003cli\u003eUnique dual case design provides additional user protection\u003c\/li\u003e\n\u003cli\u003eLithium-ion battery - extended capacity, rapid charge\u003c\/li\u003e\n\u003cli\u003eAdvanced memory with time\/date stamp\u003c\/li\u003e\n\u003cli\u003eCATIV 600V safety rating on all terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTesting the Insulation of High or Low Voltage Electric Equipment\u003c\/li\u003e\n\u003cli\u003eGenerators\u003c\/li\u003e\n\u003cli\u003eMotors\u003c\/li\u003e\n\u003cli\u003eTransformers\u003c\/li\u003e\n\u003cli\u003eCables\u003c\/li\u003e\n\u003cli\u003eSwitchgear\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage Power Cables\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage Buses\u003c\/li\u003e\n\u003cli\u003eLarge Motor\/Generator Windings\u003c\/li\u003e\n\u003cli\u003eLine and Substation Transformers\u003c\/li\u003e\n\u003cli\u003eSpot Tests\u003c\/li\u003e\n\u003cli\u003eStepvoltage Tests\u003c\/li\u003e\n\u003cli\u003eDielectric Discharge Tests\u003c\/li\u003e\n\u003cli\u003eRamp Tests\u003c\/li\u003e\n\u003cli\u003eDielectric Absorption Tests\u003c\/li\u003e\n\u003cli\u003eAcceptance Testing at Installation to Check Conformance to Specifications\u003c\/li\u003e\n\u003cli\u003eRoutine Preventive\/Predictive Maintenance Testing After Installation\u003c\/li\u003e\n\u003cli\u003eQA Testing as Part of the Manufacturing Process\u003c\/li\u003e\n\u003cli\u003eDiagnostic Testing to Isolate Faulty Components for Repair\u003c\/li\u003e\n\u003cli\u003eRotating Machinery\u003c\/li\u003e\n\u003cli\u003eInsulation Resistance of Armature and Field Windings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Insulation Range\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Insulation Range\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e250 V, 500 V, 1000 V, 2500 V, and 5000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Defined Test Voltages\u003c\/td\u003e\n\u003ctd\u003e100 V to 1 kV in 10 V Steps\u003cbr\u003e1 kV to 5 kV in 25 V Steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (23°C)\u003c\/td\u003e\n\u003ctd\u003e±5% to 1 TΩ, ±20% to 10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Accuracy (0 to 30°C)\u003c\/td\u003e\n\u003ctd\u003e4 to 0% ±10 V of nominal test voltage at 1 GΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Range\u003c\/td\u003e\n\u003ctd\u003e30 to 660 V ac or dc, 50\/60 Hz\u003cbr\u003eAccuracy: ±3% ±3 V\u003cbr\u003eFrequency Range: 45 Hz to 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current\u003c\/td\u003e\n\u003ctd\u003e3 mA Nominal, Max. Power on All Loads Outperforming Many\u003cbr\u003e5 mA Testers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Alarm\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 1 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Measurement\u003c\/td\u003e\n\u003ctd\u003eRange: 0.01 nA to 6 mA\u003cbr\u003eAccuracy: ±5% ±0.2 nA at All Voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range Above 500 V\u003c\/td\u003e\n\u003ctd\u003e10 nF to 25 µF (Dependent on Measurement Voltage)\u003cbr\u003eAccuracy (23°C): ±10% ±5 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Charge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3 s per µF at 3 mA to 5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Discharge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;250 ms\/µF to Discharge from 5000 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Range\u003c\/td\u003e\n\u003ctd\u003eUp to 99 Minutes, 15 Seconds Minimum Setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e5 1\/2 Hours Continuous Logging Every 5 Seconds or 33 Logged PI Tests or 350 Logged IR Tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustry-Standard Tests\u003c\/td\u003e\n\u003ctd\u003eIR, IR(t), DAR, PI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eUSB Type B (Device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal Time Output\u003c\/td\u003e\n\u003ctd\u003eUSB, 1 Reading\/Second (Voltage, Current and Resistance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference Rejection\u003c\/td\u003e\n\u003ctd\u003e1 mA per 250 V up to a maximum of 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuard Terminal\u003c\/td\u003e\n\u003ctd\u003e2% Error Guarding 500 kΩ Leakage with 100 mΩ Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Range\u003c\/td\u003e\n\u003ctd\u003e85 to 265 V, 50\/60 Hz, 60 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eLithium-Ion, 11.1 V, 5.2 A Hour, Meets IEC 62133:2003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eTypical Capacity 6 Hours Continuous at 5 kV with a 100 MW Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Charge Time\u003c\/td\u003e\n\u003ctd\u003e2.5 Hours from Deep Discharge, 2 Hours Normal Discharge\u003cbr\u003e30 Minutes Quick Charge: 1 Hour Operation at 5 kV, 100 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eMeets the Requirements of IEC61010-1 CAT IV 600 V\u003cbr\u003eDefault Voltmeter Warns Operator of Applied Voltage Above 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eMeets the requirements of IEC61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP65 (Lid Closed)\u003cbr\u003eIP40 (Lid Open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003eOperating: -4 to 122°F (-20 to 50°C)\u003cbr\u003eStorage: -13 to 149°F (-25 to 65°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e90% RH @ 104°F (40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e3000 m, CAT rating maintained \u0026gt;2000 m* (*test load connected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12 x 11 x 7\" (315 x 285 x 181 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 lb (4.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMegohmmeter\u003c\/li\u003e\n\u003cli\u003eUser Guide CD-ROM\u003c\/li\u003e\n\u003cli\u003ePower Lead\u003c\/li\u003e\n\u003cli\u003e3 x 3m Lead Set, Medium Insulated Clips (5 kV,10 kV)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/MIT515_525_1025_specs.pdf?1591\" target=\"_blank\" title=\"Megger MIT515 Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger MIT515 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-05-16T12:54:00-06:00","created_at":"2018-05-16T13:23:33-06:00","vendor":"Megger","type":"Insulation Testers","tags":[],"price":617000,"price_min":617000,"price_max":617000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12140920143915,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-MIT515-US","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger MIT515 5kV Insulation Tester","public_title":null,"options":["Default Title"],"price":617000,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit525-882-1.jpg?v=1526498615"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit525-882-1.jpg?v=1526498615","options":["Title"],"media":[{"alt":null,"id":1663528239147,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit525-882-1.jpg?v=1526498615"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit525-882-1.jpg?v=1526498615","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe MIT515 is the simplest of Megger's new range of small light 5 kV insulation resistance testers for the testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustry best guard terminal accuracy\u003c\/li\u003e\n\u003cli\u003eSmaller size and lightweight allows easier transport and use without compromising performance\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight for easy transport and use\u003c\/li\u003e\n\u003cli\u003eAuto IR, DAR and PI\u003c\/li\u003e\n\u003cli\u003eUnique dual case design provides additional user protection\u003c\/li\u003e\n\u003cli\u003eLithium-ion battery - extended capacity, rapid charge\u003c\/li\u003e\n\u003cli\u003eAdvanced memory with time\/date stamp\u003c\/li\u003e\n\u003cli\u003eCATIV 600V safety rating on all terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTesting the Insulation of High or Low Voltage Electric Equipment\u003c\/li\u003e\n\u003cli\u003eGenerators\u003c\/li\u003e\n\u003cli\u003eMotors\u003c\/li\u003e\n\u003cli\u003eTransformers\u003c\/li\u003e\n\u003cli\u003eCables\u003c\/li\u003e\n\u003cli\u003eSwitchgear\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage Power Cables\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage Buses\u003c\/li\u003e\n\u003cli\u003eLarge Motor\/Generator Windings\u003c\/li\u003e\n\u003cli\u003eLine and Substation Transformers\u003c\/li\u003e\n\u003cli\u003eSpot Tests\u003c\/li\u003e\n\u003cli\u003eStepvoltage Tests\u003c\/li\u003e\n\u003cli\u003eDielectric Discharge Tests\u003c\/li\u003e\n\u003cli\u003eRamp Tests\u003c\/li\u003e\n\u003cli\u003eDielectric Absorption Tests\u003c\/li\u003e\n\u003cli\u003eAcceptance Testing at Installation to Check Conformance to Specifications\u003c\/li\u003e\n\u003cli\u003eRoutine Preventive\/Predictive Maintenance Testing After Installation\u003c\/li\u003e\n\u003cli\u003eQA Testing as Part of the Manufacturing Process\u003c\/li\u003e\n\u003cli\u003eDiagnostic Testing to Isolate Faulty Components for Repair\u003c\/li\u003e\n\u003cli\u003eRotating Machinery\u003c\/li\u003e\n\u003cli\u003eInsulation Resistance of Armature and Field Windings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Insulation Range\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Insulation Range\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e250 V, 500 V, 1000 V, 2500 V, and 5000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Defined Test Voltages\u003c\/td\u003e\n\u003ctd\u003e100 V to 1 kV in 10 V Steps\u003cbr\u003e1 kV to 5 kV in 25 V Steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (23°C)\u003c\/td\u003e\n\u003ctd\u003e±5% to 1 TΩ, ±20% to 10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Accuracy (0 to 30°C)\u003c\/td\u003e\n\u003ctd\u003e4 to 0% ±10 V of nominal test voltage at 1 GΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Range\u003c\/td\u003e\n\u003ctd\u003e30 to 660 V ac or dc, 50\/60 Hz\u003cbr\u003eAccuracy: ±3% ±3 V\u003cbr\u003eFrequency Range: 45 Hz to 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current\u003c\/td\u003e\n\u003ctd\u003e3 mA Nominal, Max. Power on All Loads Outperforming Many\u003cbr\u003e5 mA Testers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Alarm\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 1 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Measurement\u003c\/td\u003e\n\u003ctd\u003eRange: 0.01 nA to 6 mA\u003cbr\u003eAccuracy: ±5% ±0.2 nA at All Voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range Above 500 V\u003c\/td\u003e\n\u003ctd\u003e10 nF to 25 µF (Dependent on Measurement Voltage)\u003cbr\u003eAccuracy (23°C): ±10% ±5 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Charge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3 s per µF at 3 mA to 5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Discharge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;250 ms\/µF to Discharge from 5000 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Range\u003c\/td\u003e\n\u003ctd\u003eUp to 99 Minutes, 15 Seconds Minimum Setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e5 1\/2 Hours Continuous Logging Every 5 Seconds or 33 Logged PI Tests or 350 Logged IR Tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustry-Standard Tests\u003c\/td\u003e\n\u003ctd\u003eIR, IR(t), DAR, PI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eUSB Type B (Device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal Time Output\u003c\/td\u003e\n\u003ctd\u003eUSB, 1 Reading\/Second (Voltage, Current and Resistance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference Rejection\u003c\/td\u003e\n\u003ctd\u003e1 mA per 250 V up to a maximum of 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuard Terminal\u003c\/td\u003e\n\u003ctd\u003e2% Error Guarding 500 kΩ Leakage with 100 mΩ Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Range\u003c\/td\u003e\n\u003ctd\u003e85 to 265 V, 50\/60 Hz, 60 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eLithium-Ion, 11.1 V, 5.2 A Hour, Meets IEC 62133:2003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eTypical Capacity 6 Hours Continuous at 5 kV with a 100 MW Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Charge Time\u003c\/td\u003e\n\u003ctd\u003e2.5 Hours from Deep Discharge, 2 Hours Normal Discharge\u003cbr\u003e30 Minutes Quick Charge: 1 Hour Operation at 5 kV, 100 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eMeets the Requirements of IEC61010-1 CAT IV 600 V\u003cbr\u003eDefault Voltmeter Warns Operator of Applied Voltage Above 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eMeets the requirements of IEC61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP65 (Lid Closed)\u003cbr\u003eIP40 (Lid Open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003eOperating: -4 to 122°F (-20 to 50°C)\u003cbr\u003eStorage: -13 to 149°F (-25 to 65°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e90% RH @ 104°F (40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e3000 m, CAT rating maintained \u0026gt;2000 m* (*test load connected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12 x 11 x 7\" (315 x 285 x 181 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 lb (4.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMegohmmeter\u003c\/li\u003e\n\u003cli\u003eUser Guide CD-ROM\u003c\/li\u003e\n\u003cli\u003ePower Lead\u003c\/li\u003e\n\u003cli\u003e3 x 3m Lead Set, Medium Insulated Clips (5 kV,10 kV)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/MIT515_525_1025_specs.pdf?1591\" target=\"_blank\" title=\"Megger MIT515 Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger MIT515 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger MIT515 5kV Insulation Tester

Megger MIT515 5kV Insulation Tester

$6,170.00 CAD

The MIT515 is the simplest of Megger's new range of small light 5 kV insulation resistance testers for the testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store. Overview Features Industry best guard terminal accuracy S...


More Info
Megger MIT525 5kV Insulation Tester

Insulation Testers

$8,055.00 CAD
{"id":1262843363371,"title":"Megger MIT525 5kV Insulation Tester","handle":"megger-mit525-5kv-insulation-tester","description":"\u003cp\u003eThe MIT525 is compact, light 5 kV insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. It is both smaller and lighter than its predecessor, making it even easier to carry and store.\u003c\/p\u003e\n\u003cp\u003eAs well as measuring insulation resistance to 10 TΩ, the MIT525 also offers various diagnostic tests such as polarisation index, dielectric absorption ratio, step voltage, dielectric discharge and ramp testing.\u003c\/p\u003e\n\u003cp\u003eNow equipped with lithium ion fast rechargeable batteries, the instrument has a large, clear, easy-to-read display, making it equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly removing the need for separate timer.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustry best guard terminal accuracy\u003c\/li\u003e\n\u003cli\u003eSmaller size and lightweight allows easier transport and use without compromising performance\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight for easy transport and use\u003c\/li\u003e\n\u003cli\u003eAuto IR, DAR, PI, Step Voltage, DD and Ramp\u003c\/li\u003e\n\u003cli\u003eUnique dual case design provides additional user protection\u003c\/li\u003e\n\u003cli\u003eLithium-ion battery - extended capacity, rapid charge\u003c\/li\u003e\n\u003cli\u003eAdvanced memory with time\/date stamp\u003c\/li\u003e\n\u003cli\u003eCATIV 600V safety rating on all terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Range, Analog\u003c\/td\u003e\n\u003ctd\u003e100kW to 10TW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Range, Digital\u003c\/td\u003e\n\u003ctd\u003e10kW to 10TW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e250V, 500V, 1000V, 2500V, and 5000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Defined Test Voltages\u003c\/td\u003e\n\u003ctd\u003e100V to 1kV in 10V steps, 1kV to 5kV in 25V steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±5% to 1TΩ, ±20% to 10TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Accuracy\u003c\/td\u003e\n\u003ctd\u003e+4% -0% ±10V of nominal test voltage at 1GW load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Range\u003c\/td\u003e\n\u003ctd\u003e30 to 660V AC\/DC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3% ±3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e45Hz to 65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current\u003c\/td\u003e\n\u003ctd\u003e3mA nominal, max. power on all loads outperforming many 5 mA testers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Alarm\u003c\/td\u003e\n\u003ctd\u003e100kΩ to 1GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e0.01nA to 6mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% ±0.2nA at all voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range (above 500V)\u003c\/td\u003e\n\u003ctd\u003e10nF to 25µF (dependent on measurement voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10% ±5nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Charge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3 s per µF at 3 mA to 5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Discharge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;250 ms\/µF to discharge from 5000V to 50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMIT525 Megohmmeter\u003c\/li\u003e\n\u003cli\u003ePower lead\u003c\/li\u003e\n\u003cli\u003e3 x 1002-531 Medium insulated clips, 10ft (3m) leadset\u003c\/li\u003e\n\u003cli\u003eUser guide CD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/MIT515_525_1025_specs.pdf?1591\" target=\"_blank\" title=\"Megger MIT525 Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger MIT525 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-05-16T12:44:52-06:00","created_at":"2018-05-16T12:47:23-06:00","vendor":"Megger","type":"Insulation Testers","tags":[],"price":805500,"price_min":805500,"price_max":805500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12140514017323,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-MIT525-US","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger MIT525 5kV Insulation Tester","public_title":null,"options":["Default Title"],"price":805500,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit525-882.jpg?v=1526496446"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit525-882.jpg?v=1526496446","options":["Title"],"media":[{"alt":null,"id":1663418368043,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit525-882.jpg?v=1526496446"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit525-882.jpg?v=1526496446","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe MIT525 is compact, light 5 kV insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. It is both smaller and lighter than its predecessor, making it even easier to carry and store.\u003c\/p\u003e\n\u003cp\u003eAs well as measuring insulation resistance to 10 TΩ, the MIT525 also offers various diagnostic tests such as polarisation index, dielectric absorption ratio, step voltage, dielectric discharge and ramp testing.\u003c\/p\u003e\n\u003cp\u003eNow equipped with lithium ion fast rechargeable batteries, the instrument has a large, clear, easy-to-read display, making it equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly removing the need for separate timer.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustry best guard terminal accuracy\u003c\/li\u003e\n\u003cli\u003eSmaller size and lightweight allows easier transport and use without compromising performance\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight for easy transport and use\u003c\/li\u003e\n\u003cli\u003eAuto IR, DAR, PI, Step Voltage, DD and Ramp\u003c\/li\u003e\n\u003cli\u003eUnique dual case design provides additional user protection\u003c\/li\u003e\n\u003cli\u003eLithium-ion battery - extended capacity, rapid charge\u003c\/li\u003e\n\u003cli\u003eAdvanced memory with time\/date stamp\u003c\/li\u003e\n\u003cli\u003eCATIV 600V safety rating on all terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Range, Analog\u003c\/td\u003e\n\u003ctd\u003e100kW to 10TW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Range, Digital\u003c\/td\u003e\n\u003ctd\u003e10kW to 10TW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e250V, 500V, 1000V, 2500V, and 5000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Defined Test Voltages\u003c\/td\u003e\n\u003ctd\u003e100V to 1kV in 10V steps, 1kV to 5kV in 25V steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±5% to 1TΩ, ±20% to 10TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Accuracy\u003c\/td\u003e\n\u003ctd\u003e+4% -0% ±10V of nominal test voltage at 1GW load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Range\u003c\/td\u003e\n\u003ctd\u003e30 to 660V AC\/DC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3% ±3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e45Hz to 65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current\u003c\/td\u003e\n\u003ctd\u003e3mA nominal, max. power on all loads outperforming many 5 mA testers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Alarm\u003c\/td\u003e\n\u003ctd\u003e100kΩ to 1GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e0.01nA to 6mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% ±0.2nA at all voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range (above 500V)\u003c\/td\u003e\n\u003ctd\u003e10nF to 25µF (dependent on measurement voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10% ±5nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Charge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3 s per µF at 3 mA to 5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Discharge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;250 ms\/µF to discharge from 5000V to 50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMIT525 Megohmmeter\u003c\/li\u003e\n\u003cli\u003ePower lead\u003c\/li\u003e\n\u003cli\u003e3 x 1002-531 Medium insulated clips, 10ft (3m) leadset\u003c\/li\u003e\n\u003cli\u003eUser guide CD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/MIT515_525_1025_specs.pdf?1591\" target=\"_blank\" title=\"Megger MIT525 Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger MIT525 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger MIT525 5kV Insulation Tester

Megger MIT525 5kV Insulation Tester

$8,055.00 CAD

The MIT525 is compact, light 5 kV insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. It is both smaller and lighter than its predecessor, making it even easier to carry and store. As well as measuring insulation resistance to 10 TΩ, the MIT525 also offers various diagnostic tests such as...


More Info
Megger MIT1025 10kV Insulation Tester

Insulation Testers

$9,785.00 CAD
{"id":1262797520939,"title":"Megger MIT1025 10kV Insulation Tester","handle":"megger-mit1025-10kv-insulation-tester","description":"\u003cp\u003eThe MIT1025 is compact, light 10 kV insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store.\u003c\/p\u003e\n\u003cp\u003eAs well as measuring insulation resistance to 20 TΩ, the MIT1025 also offers various diagnostic tests such as Polarization index, Dielectric Absorption Ratio, Step Voltage, Dielectric discharge and ramp testing.\u003c\/p\u003e\n\u003cp\u003eNow equipped with lithium ion fast rechargeable batteries, the instrument has a large, clear, easy to read, display making it equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly removing the need for separate timer.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustry best guard terminal accuracy\u003c\/li\u003e\n\u003cli\u003eSmaller size and lightweight allows easier transport and use without compromising performance\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight for easy transport and use\u003c\/li\u003e\n\u003cli\u003eAuto IR, DAR, PI, Step Voltage, DD and Ramp\u003c\/li\u003e\n\u003cli\u003eUnique dual case design provides additional user protection\u003c\/li\u003e\n\u003cli\u003eLithium-ion battery - extended capacity rapid charge\u003c\/li\u003e\n\u003cli\u003eAdvanced memory with time\/date stamp\u003c\/li\u003e\n\u003cli\u003eCATIV 600V safety rating on all terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical contractors\u003c\/li\u003e\n\u003cli\u003eTesting and service companies\u003c\/li\u003e\n\u003cli\u003eWind farm and solar generation operators\u003c\/li\u003e\n\u003cli\u003ePower generation and distribution companies\u003c\/li\u003e\n\u003cli\u003eIndustrial companies\u003c\/li\u003e\n\u003cli\u003eRail companies\u003c\/li\u003e\n\u003cli\u003eAcceptance testing at installation to check conformance to specifications\u003c\/li\u003e\n\u003cli\u003eRoutine preventive\/predictive maintenance testing after installation\u003c\/li\u003e\n\u003cli\u003eQA testing as part of the manufacturing process\u003c\/li\u003e\n\u003cli\u003eDiagnostic testing to isolate faulty components for repair\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Range, Analog\u003c\/td\u003e\n\u003ctd\u003e100kW to 10TW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Range, Digital\u003c\/td\u003e\n\u003ctd\u003e10kW to 20TW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e500V, 1000V, 2500V, 5000V, and 10,000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Defined Test Voltages\u003c\/td\u003e\n\u003ctd\u003e100V to 1kV in 10V steps\u003cbr\u003e1kV to 5kV in 25V steps\u003cbr\u003e5kV to 10kV in 25V steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±5% to 2TΩ, ±20% to 20TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Accuracy\u003c\/td\u003e\n\u003ctd\u003e+4% -0% ±10V of nominal test voltage at 1GW load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Range\u003c\/td\u003e\n\u003ctd\u003e30 to 660V AC\/DC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3% ±3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e45 to 65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current\u003c\/td\u003e\n\u003ctd\u003e3mA nominal, max. power on all loads outperforming many 5mA testers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Alarm\u003c\/td\u003e\n\u003ctd\u003e100kΩ to 1GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e0.01nA to 6mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% ±0.2 nA at all voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range (above 500V)\u003c\/td\u003e\n\u003ctd\u003e10nF to 25µF (dependent on measurement voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10% ±5nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Charge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5s per µF at 3mA to 10kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Discharge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;500 ms\/µF to discharge from 10,000V to 50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMIT1025 Megohmmeter\u003c\/li\u003e\n\u003cli\u003ePower lead\u003c\/li\u003e\n\u003cli\u003e3 x 1002-531 Medium insulated clips, 10ft (3m) leadset\u003c\/li\u003e\n\u003cli\u003e3 x 1002-534 Large insulated clips, 10ft (3m) leadset\u003c\/li\u003e\n\u003cli\u003eUser guide CD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/MIT515_525_1025_specs.pdf?1591\" target=\"_blank\" title=\"Megger MIT1025 Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger MIT1025 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-05-16T12:41:14-06:00","created_at":"2018-05-16T12:41:17-06:00","vendor":"Megger","type":"Insulation Testers","tags":[],"price":978500,"price_min":978500,"price_max":978500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12140446318635,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MEG-MIT1025-US","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger MIT1025 10kV Insulation Tester","public_title":null,"options":["Default Title"],"price":978500,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit1025-f26.jpg?v=1526496155"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit1025-f26.jpg?v=1526496155","options":["Title"],"media":[{"alt":null,"id":1663398969387,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit1025-f26.jpg?v=1526496155"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit1025-f26.jpg?v=1526496155","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe MIT1025 is compact, light 10 kV insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store.\u003c\/p\u003e\n\u003cp\u003eAs well as measuring insulation resistance to 20 TΩ, the MIT1025 also offers various diagnostic tests such as Polarization index, Dielectric Absorption Ratio, Step Voltage, Dielectric discharge and ramp testing.\u003c\/p\u003e\n\u003cp\u003eNow equipped with lithium ion fast rechargeable batteries, the instrument has a large, clear, easy to read, display making it equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly removing the need for separate timer.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustry best guard terminal accuracy\u003c\/li\u003e\n\u003cli\u003eSmaller size and lightweight allows easier transport and use without compromising performance\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight for easy transport and use\u003c\/li\u003e\n\u003cli\u003eAuto IR, DAR, PI, Step Voltage, DD and Ramp\u003c\/li\u003e\n\u003cli\u003eUnique dual case design provides additional user protection\u003c\/li\u003e\n\u003cli\u003eLithium-ion battery - extended capacity rapid charge\u003c\/li\u003e\n\u003cli\u003eAdvanced memory with time\/date stamp\u003c\/li\u003e\n\u003cli\u003eCATIV 600V safety rating on all terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eElectrical contractors\u003c\/li\u003e\n\u003cli\u003eTesting and service companies\u003c\/li\u003e\n\u003cli\u003eWind farm and solar generation operators\u003c\/li\u003e\n\u003cli\u003ePower generation and distribution companies\u003c\/li\u003e\n\u003cli\u003eIndustrial companies\u003c\/li\u003e\n\u003cli\u003eRail companies\u003c\/li\u003e\n\u003cli\u003eAcceptance testing at installation to check conformance to specifications\u003c\/li\u003e\n\u003cli\u003eRoutine preventive\/predictive maintenance testing after installation\u003c\/li\u003e\n\u003cli\u003eQA testing as part of the manufacturing process\u003c\/li\u003e\n\u003cli\u003eDiagnostic testing to isolate faulty components for repair\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Range, Analog\u003c\/td\u003e\n\u003ctd\u003e100kW to 10TW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Range, Digital\u003c\/td\u003e\n\u003ctd\u003e10kW to 20TW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e500V, 1000V, 2500V, 5000V, and 10,000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Defined Test Voltages\u003c\/td\u003e\n\u003ctd\u003e100V to 1kV in 10V steps\u003cbr\u003e1kV to 5kV in 25V steps\u003cbr\u003e5kV to 10kV in 25V steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±5% to 2TΩ, ±20% to 20TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Accuracy\u003c\/td\u003e\n\u003ctd\u003e+4% -0% ±10V of nominal test voltage at 1GW load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Range\u003c\/td\u003e\n\u003ctd\u003e30 to 660V AC\/DC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3% ±3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e45 to 65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current\u003c\/td\u003e\n\u003ctd\u003e3mA nominal, max. power on all loads outperforming many 5mA testers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Alarm\u003c\/td\u003e\n\u003ctd\u003e100kΩ to 1GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e0.01nA to 6mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% ±0.2 nA at all voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range (above 500V)\u003c\/td\u003e\n\u003ctd\u003e10nF to 25µF (dependent on measurement voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10% ±5nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Charge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;5s per µF at 3mA to 10kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Discharge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;500 ms\/µF to discharge from 10,000V to 50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMIT1025 Megohmmeter\u003c\/li\u003e\n\u003cli\u003ePower lead\u003c\/li\u003e\n\u003cli\u003e3 x 1002-531 Medium insulated clips, 10ft (3m) leadset\u003c\/li\u003e\n\u003cli\u003e3 x 1002-534 Large insulated clips, 10ft (3m) leadset\u003c\/li\u003e\n\u003cli\u003eUser guide CD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/MIT515_525_1025_specs.pdf?1591\" target=\"_blank\" title=\"Megger MIT1025 Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger MIT1025 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger MIT1025 10kV Insulation Tester

Megger MIT1025 10kV Insulation Tester

$9,785.00 CAD

The MIT1025 is compact, light 10 kV insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store. As well as measuring insulation resistance to 20 TΩ, the MIT1025 also offers vario...


More Info
{"id":1122433728555,"title":"Fluke 1577 Insulation Multimeter *** SEE FLUKE 1587FC***","handle":"fluke-1577-insulation-multimeter","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe Fluke 1577 Insulation Multimeter combine a \u003c\/span\u003e\u003ca title=\"Insulation Resistance Testers\" href=\"http:\/\/en-us.fluke.com\/products\/insulation-testers\/fluke-1555-electrical-tester.html\"\u003edigital insulation tester\u003c\/a\u003e\u003cspan\u003e with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.\u003c\/span\u003e","published_at":"2018-03-23T16:57:27-06:00","created_at":"2018-03-23T17:00:57-06:00","vendor":"Fluke","type":"Insulation Testers","tags":[],"price":132327,"price_min":132327,"price_max":132327,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11328867336235,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-1577","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1577 Insulation Multimeter *** SEE FLUKE 1587FC***","public_title":null,"options":["Default Title"],"price":132327,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969262965","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1577.jpg?v=1521846059"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1577.jpg?v=1521846059","options":["Title"],"media":[{"alt":null,"id":1517856030763,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1577.jpg?v=1521846059"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1577.jpg?v=1521846059","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe Fluke 1577 Insulation Multimeter combine a \u003c\/span\u003e\u003ca title=\"Insulation Resistance Testers\" href=\"http:\/\/en-us.fluke.com\/products\/insulation-testers\/fluke-1555-electrical-tester.html\"\u003edigital insulation tester\u003c\/a\u003e\u003cspan\u003e with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.\u003c\/span\u003e"}
Fluke 1577 Insulation Multimeter *** SEE FLUKE 1587FC***

Fluke 1577 Insulation Multimeter *** SEE FLUKE 1587FC***

$1,323.27 CAD

The Fluke 1577 Insulation Multimeter combine a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.


More Info
Fluke 1507 Insulation Resistance Tester

Insulation Testers

$1,165.51 CAD
{"id":1076405272619,"title":"Fluke 1507 Insulation Resistance Tester","handle":"fluke-1507-insulation-resistance-tester","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications.\u003c\/p\u003e\n\u003cp\u003eTake advantage of the 1507 full feature set to easily and quickly perform advanced insulation resistance testing. Its handy size and light weight make it easy to pack and use. Additional features, like the remote probe, save both time and money especially when performing repetitive tests. And its reasonable price and rugged reliability make it an excellent value.\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRugged, compact advanced insulation resistance tester for electrical contractors and industrial and commercial electricians\u003c\/li\u003e\n\u003cli\u003eAutomatically calculates Polarization Index and Dielectric Absorption Ratio\u003c\/li\u003e\n\u003cli\u003eMakes repetitive tests simple and easy with a Compare (Pass\/Fail) function \u003c\/li\u003e\n\u003cli\u003eOffers multiple insulation test voltages: 50 V, 100 V, 250 V, 500 V, and  1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePerforms insulation tests from 0.01 MΩ to 2.0 GΩ\u003c\/li\u003e\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage from 0.1 V to 600 V and resistance from 0.01 Ω to 20.00 kΩ\u003c\/li\u003e\n\u003cli\u003eProvides lo-ohms earth-bond continuity (200 mA)\u003c\/li\u003e\n\u003cli\u003eSimplifies repetitive or hard-to-reach testing with the remote test probe\u003c\/li\u003e\n\u003cli\u003eSaves battery power with auto power off\u003c\/li\u003e\n\u003cli\u003ePresents results on a large, backlit display\u003c\/li\u003e\n\u003cli\u003eFeatures CAT IV 600 V overvoltage category rating\u003c\/li\u003e\n\u003cli\u003eComes with remote probe, test leads, test probes, alligator clips and one-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC\/DC Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 Hz to 400 Hz ± (% of Rdg + Digits)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 MΩ (nominal), \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio (1 kΩ unbalanced):\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 60 dB at DC, 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEarth Bond Resistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e20.00 Ω\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200.0 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003e1.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit test voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 4.0 V, \u0026lt; 8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 200.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInsulation Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+ 20%, - 0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto discharge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDischarge time \u0026lt; 0.5 second for C = 1 µF or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive circuit indicator\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInhibit test if terminal voltage \u0026gt; 30 V prior to initialization of test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOperable with up to 1 µF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eMeasure accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e50 V\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage applied to any terminal:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V AC rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.05 x (specified accuracy) per °C for temperatures \u0026lt; 18°C or \u0026gt; 28°C (\u0026lt; 64°F or \u0026gt; 82°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRelative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 95% @ 10°C to 30°C (50°F to 86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 75% @ 30°C to 40°C (86°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 40% @ 40°C to 55°C (104°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIn an RF field of 3 V\/M, accuracy = specified accuracy (EN 61326-1:1997)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eComplies with ANSI\/ISA 82.02.01 (61010-1) 2004, CAN\/CSA-C22.2 NO. 61010-1-04, and IEC\/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA per standard CSA\/CAN C22.2 No. 61010.1-04; TUV per standard IEC\/EN 61010-1 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFour AA batteries (NEDA 15A or IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eInsulation test use:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance measurements:\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOperating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m CAT IV 600 V, 3000 m CAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating (storage)\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-range capability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e110% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded accessories\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1507 Insulation Tester\u003c\/li\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eTest probes\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1507_and_1503_Spec.pdf?1803\" target=\"_blank\" title=\"Fluke 1507 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1507 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2018-03-07T15:10:22-07:00","created_at":"2018-03-07T15:13:21-07:00","vendor":"Fluke","type":"Insulation Testers","tags":[],"price":116551,"price_min":116551,"price_max":116551,"available":true,"price_varies":false,"compare_at_price":84000,"compare_at_price_min":84000,"compare_at_price_max":84000,"compare_at_price_varies":false,"variants":[{"id":11043776004139,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-1507","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1507 Insulation Resistance Tester","public_title":null,"options":["Default Title"],"price":116551,"weight":2268,"compare_at_price":84000,"inventory_management":"shopify","barcode":"095969288675","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke1507-2.png?v=1520460804"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke1507-2.png?v=1520460804","options":["Title"],"media":[{"alt":null,"id":1476022861867,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1050,"width":1050,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke1507-2.png?v=1520460804"},"aspect_ratio":1.0,"height":1050,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke1507-2.png?v=1520460804","width":1050}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications.\u003c\/p\u003e\n\u003cp\u003eTake advantage of the 1507 full feature set to easily and quickly perform advanced insulation resistance testing. Its handy size and light weight make it easy to pack and use. Additional features, like the remote probe, save both time and money especially when performing repetitive tests. And its reasonable price and rugged reliability make it an excellent value.\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRugged, compact advanced insulation resistance tester for electrical contractors and industrial and commercial electricians\u003c\/li\u003e\n\u003cli\u003eAutomatically calculates Polarization Index and Dielectric Absorption Ratio\u003c\/li\u003e\n\u003cli\u003eMakes repetitive tests simple and easy with a Compare (Pass\/Fail) function \u003c\/li\u003e\n\u003cli\u003eOffers multiple insulation test voltages: 50 V, 100 V, 250 V, 500 V, and  1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePerforms insulation tests from 0.01 MΩ to 2.0 GΩ\u003c\/li\u003e\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage from 0.1 V to 600 V and resistance from 0.01 Ω to 20.00 kΩ\u003c\/li\u003e\n\u003cli\u003eProvides lo-ohms earth-bond continuity (200 mA)\u003c\/li\u003e\n\u003cli\u003eSimplifies repetitive or hard-to-reach testing with the remote test probe\u003c\/li\u003e\n\u003cli\u003eSaves battery power with auto power off\u003c\/li\u003e\n\u003cli\u003ePresents results on a large, backlit display\u003c\/li\u003e\n\u003cli\u003eFeatures CAT IV 600 V overvoltage category rating\u003c\/li\u003e\n\u003cli\u003eComes with remote probe, test leads, test probes, alligator clips and one-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC\/DC Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 Hz to 400 Hz ± (% of Rdg + Digits)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 MΩ (nominal), \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio (1 kΩ unbalanced):\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 60 dB at DC, 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEarth Bond Resistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e20.00 Ω\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200.0 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003e1.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit test voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 4.0 V, \u0026lt; 8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 200.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInsulation Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+ 20%, - 0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto discharge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDischarge time \u0026lt; 0.5 second for C = 1 µF or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive circuit indicator\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInhibit test if terminal voltage \u0026gt; 30 V prior to initialization of test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOperable with up to 1 µF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eMeasure accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e50 V\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage applied to any terminal:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V AC rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.05 x (specified accuracy) per °C for temperatures \u0026lt; 18°C or \u0026gt; 28°C (\u0026lt; 64°F or \u0026gt; 82°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRelative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 95% @ 10°C to 30°C (50°F to 86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 75% @ 30°C to 40°C (86°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 40% @ 40°C to 55°C (104°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIn an RF field of 3 V\/M, accuracy = specified accuracy (EN 61326-1:1997)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eComplies with ANSI\/ISA 82.02.01 (61010-1) 2004, CAN\/CSA-C22.2 NO. 61010-1-04, and IEC\/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA per standard CSA\/CAN C22.2 No. 61010.1-04; TUV per standard IEC\/EN 61010-1 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFour AA batteries (NEDA 15A or IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eInsulation test use:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance measurements:\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOperating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m CAT IV 600 V, 3000 m CAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating (storage)\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-range capability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e110% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded accessories\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1507 Insulation Tester\u003c\/li\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eTest probes\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1507_and_1503_Spec.pdf?1803\" target=\"_blank\" title=\"Fluke 1507 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1507 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e"}
Fluke 1507 Insulation Resistance Tester

Fluke 1507 Insulation Resistance Tester

$1,165.51 CAD

The Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications. Take advantage of the 1507 full feature set to easily and quickly perform advanced ins...


More Info
Fluke 1587FC Insulation Multimeter

Insulation Testers

$1,423.42 CAD
{"id":1076190609451,"title":"Fluke 1587FC Insulation Multimeter","handle":"fluke-1587fc-insulation-multimeter","description":"\u003cp\u003e\u003cspan\u003eFluke Connect + Fluke's 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 1587 FC is Fluke Connect-enabled so you can download the free Fluke Connect® Measurements app to your smartphone and gain additional functions, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSafety first. Keep yourself out of harm’s way by monitoring your test measurements remotely.\u003c\/li\u003e\n\u003cli\u003eProve your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone.\u003c\/li\u003e\n\u003cli\u003eQuickly find problems by saving and comparing measurements over time on a wireless device.\u003c\/li\u003e\n\u003cli\u003ePI\/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster\u003c\/li\u003e\n\u003cli\u003eMemory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time\u003c\/li\u003e\n\u003cli\u003eTemperature compensation to establish accurate baselines and relevant historical comparisons\u003c\/li\u003e\n\u003cli\u003eHistorical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect® Assets (sold separately)\u003c\/li\u003e\n\u003cli\u003eProvides memory storage through Fluke Connect Measurements to eliminate the need to write down results\u003c\/li\u003e\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli\u003eProvides automated temperature compensation to establish accurate baselines\u003c\/li\u003e\n\u003cli\u003eSupports historical tracking and asset trending of assets to identify degradation over time with Fluke Connect® Assets (sold separately)\u003c\/li\u003e\n\u003cli\u003eIncorporates VFD low-pass filter for accurate variable frequency motor drive measurements\u003c\/li\u003e\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli\u003eMeasures ac\/dc voltage, dc millivolts, ac\/dc milliamps, resistance, and continuity\u003c\/li\u003e\n\u003cli\u003eIncludes capacitance, diode test, temperature, min\/max, frequency measurements and insulation test smoothing reading\u003c\/li\u003e\n\u003cli\u003eAutomatically powers off to save battery power\u003c\/li\u003e\n\u003cli\u003eComes with remote probe, test leads, alligator clips, K-type thermocouple, hard case, and three-year warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003eSee Resources for Product Data Sheet\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eIncludes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eK-type thermocouple\u003c\/li\u003e\n\u003cli\u003eHard case\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1587FC.pdf?1805\" target=\"_blank\" title=\"Fluke 1587FC Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1587FC Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-03-07T13:35:29-07:00","created_at":"2018-03-07T13:38:36-07:00","vendor":"Fluke","type":"Insulation Testers","tags":[],"price":142342,"price_min":142342,"price_max":142342,"available":true,"price_varies":false,"compare_at_price":109600,"compare_at_price_min":109600,"compare_at_price_max":109600,"compare_at_price_varies":false,"variants":[{"id":11042213199915,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-1587FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1587FC Insulation Multimeter","public_title":null,"options":["Default Title"],"price":142342,"weight":4536,"compare_at_price":109600,"inventory_management":"shopify","barcode":"095969796620","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1587FC_BHD.jpg?v=1520455118","\/\/kingswayinstruments.com\/cdn\/shop\/products\/FLU4691215.jpg?v=1520455119"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1587FC_BHD.jpg?v=1520455118","options":["Title"],"media":[{"alt":null,"id":1475833528363,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1587FC_BHD.jpg?v=1520455118"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1587FC_BHD.jpg?v=1520455118","width":1200},{"alt":null,"id":1475833659435,"position":2,"preview_image":{"aspect_ratio":1.24,"height":900,"width":1116,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FLU4691215.jpg?v=1520455119"},"aspect_ratio":1.24,"height":900,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FLU4691215.jpg?v=1520455119","width":1116}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eFluke Connect + Fluke's 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 1587 FC is Fluke Connect-enabled so you can download the free Fluke Connect® Measurements app to your smartphone and gain additional functions, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSafety first. Keep yourself out of harm’s way by monitoring your test measurements remotely.\u003c\/li\u003e\n\u003cli\u003eProve your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone.\u003c\/li\u003e\n\u003cli\u003eQuickly find problems by saving and comparing measurements over time on a wireless device.\u003c\/li\u003e\n\u003cli\u003ePI\/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster\u003c\/li\u003e\n\u003cli\u003eMemory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time\u003c\/li\u003e\n\u003cli\u003eTemperature compensation to establish accurate baselines and relevant historical comparisons\u003c\/li\u003e\n\u003cli\u003eHistorical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect® Assets (sold separately)\u003c\/li\u003e\n\u003cli\u003eProvides memory storage through Fluke Connect Measurements to eliminate the need to write down results\u003c\/li\u003e\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli\u003eProvides automated temperature compensation to establish accurate baselines\u003c\/li\u003e\n\u003cli\u003eSupports historical tracking and asset trending of assets to identify degradation over time with Fluke Connect® Assets (sold separately)\u003c\/li\u003e\n\u003cli\u003eIncorporates VFD low-pass filter for accurate variable frequency motor drive measurements\u003c\/li\u003e\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli\u003eMeasures ac\/dc voltage, dc millivolts, ac\/dc milliamps, resistance, and continuity\u003c\/li\u003e\n\u003cli\u003eIncludes capacitance, diode test, temperature, min\/max, frequency measurements and insulation test smoothing reading\u003c\/li\u003e\n\u003cli\u003eAutomatically powers off to save battery power\u003c\/li\u003e\n\u003cli\u003eComes with remote probe, test leads, alligator clips, K-type thermocouple, hard case, and three-year warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003eSee Resources for Product Data Sheet\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eIncludes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eK-type thermocouple\u003c\/li\u003e\n\u003cli\u003eHard case\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1587FC.pdf?1805\" target=\"_blank\" title=\"Fluke 1587FC Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1587FC Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 1587FC Insulation Multimeter

Fluke 1587FC Insulation Multimeter

$1,423.42 CAD

Fluke Connect + Fluke's 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance. Overview The Fluke 1587 FC is Fluke Connect-enabled so you can download the free Fluke Connect® Measurements app to your smartphone and gain additional functions, includi...


More Info
{"id":1072453517355,"title":"Fluke 1587\/MDT FC Advanced Motor and Drive Troubleshooting Kit","handle":"fluke-1587-mdt-advanced-motor-drive-troubleshooting-kit","description":"\u003cp\u003e\u003cstrong\u003eThe Fluke 1587 FC Insulation Multimeter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures four powerful new diagnostic functions through the Fluke Connect Measurements app:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePl\/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster\u003c\/li\u003e\n\u003cli\u003eMemory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time\u003c\/li\u003e\n\u003cli\u003eTemperature Compensation through app for establishing accurate baselines and relevant historical comparisons\u003c\/li\u003e\n\u003cli\u003eHistorical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke i400 AC Current Clamp\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-safety current clamp for digital multimeters. The current clamp provides accurate current measurements without breaking electric circuits, helping you take measurements safely with industry standard safety ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 9040 Phase Rotation Indicator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis effective for measuring phase rotation in all areas where three phase supplies are used to feed motors, drives and electrical systems. It allows rapid determination of phase sequence and ideally suited for commercial and industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes a Fluke 1587 FC 2-in-1 Insulation DMM, Fluke i400 Current Clamp, and a Fluke 9040 Phase Rotation Indicator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWith the Fluke 1587 FC, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease\u003c\/li\u003e\n\u003cli\u003eUse the Fluke i400 with your Fluke 1587 FC to accurately measure AC current without breaking the circuit\u003c\/li\u003e\n\u003cli\u003eCheck the rotation of three-phase motors easily and safely with the Fluke 9040\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke 1587 FC 2-in-1 Insulation DMM\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePl\/DAR measurements with TrendIt™ graphs\u003c\/li\u003e\n\u003cli\u003eMemory storage through Fluke Connect Measurements app\u003c\/li\u003e\n\u003cli\u003eTemperature Compensation through Fluke Connect Measurements app\u003c\/li\u003e\n\u003cli\u003eVFD low-pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eInsulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/li\u003e\n\u003cli\u003eInsulation test voltages 500 V, 1000 V\u003c\/li\u003e\n\u003cli\u003eInsulation test: 0.01 MΩ to 2.0 GΩ\u003c\/li\u003e\n\u003cli\u003eInsulation test: 0.1 MΩ to 600 MΩ\u003c\/li\u003e\n\u003cli\u003eAuto-discharge of capacitive voltage\u003c\/li\u003e\n\u003cli\u003eInsulation test smoothing reading\u003c\/li\u003e\n\u003cli\u003eFrequency \/ Capacitance \/ Diode test \/ Temperature\u003c\/li\u003e\n\u003cli\u003eMin\/Max \/ AC\/DC Voltage \/ DC Millivolts \/ AC\/DC Milliamps\u003c\/li\u003e\n\u003cli\u003eResistance (0.1 Ω to 50 MΩ) \/ Continuity \/ Auto power off\u003c\/li\u003e\n\u003cli\u003eThree-year warranty \/ Remote probe, test leads, alligator clips, K-type thermocouple, hard case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke i400 AC Current Clamp\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse with your Fluke 1587 FC to measure 1A AC to 400 A AC\u003c\/li\u003e\n\u003cli\u003e1 mA\/Amp output guarantees easy reading\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V \/ CAT IV 600 V overvoltage rating for added user protection\u003c\/li\u003e\n\u003cli\u003eSpecially designed to offer maximum utility in a very compact shape\u003c\/li\u003e\n\u003cli\u003eMaximum conductor: Ø 32 mm\u003c\/li\u003e\n\u003cli\u003e1 year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 9040 Phase Rotation Indicator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLarge display to easily determine field rotation and phase sequence\u003c\/li\u003e\n\u003cli\u003eIndication for all three phases\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V overvoltage rating\u003c\/li\u003e\n\u003cli\u003e2 year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1587 FC Insulation Multimeter\u003c\/li\u003e\n\u003cli\u003ei400 Current Clamp\u003c\/li\u003e\n\u003cli\u003e9040 Phase Rotation Indicator\u003c\/li\u003e\n\u003cli\u003eRemote Probe\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003cli\u003eAlligator Clips\u003c\/li\u003e\n\u003cli\u003eK-Type Thermocouple\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003cli\u003eUser Documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1587FC.pdf?1805\" target=\"_blank\" title=\"Fluke 1587FC Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1587FC Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2018-03-06T16:07:50-07:00","created_at":"2018-03-06T16:10:32-07:00","vendor":"Fluke","type":"Insulation Testers","tags":[],"price":213383,"price_min":213383,"price_max":213383,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11020100436011,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-1587FC\/MDT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1587\/MDT FC Advanced Motor and Drive Troubleshooting Kit","public_title":null,"options":["Default Title"],"price":213383,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969797283","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/91tKJQ_eusL._SL1500.jpg?v=1520377834","\/\/kingswayinstruments.com\/cdn\/shop\/products\/2PY96_AS01.jpg?v=1520377835"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/91tKJQ_eusL._SL1500.jpg?v=1520377834","options":["Title"],"media":[{"alt":null,"id":1472794099755,"position":1,"preview_image":{"aspect_ratio":1.272,"height":1179,"width":1500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/91tKJQ_eusL._SL1500.jpg?v=1520377834"},"aspect_ratio":1.272,"height":1179,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/91tKJQ_eusL._SL1500.jpg?v=1520377834","width":1500},{"alt":null,"id":1472794132523,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/2PY96_AS01.jpg?v=1520377835"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/2PY96_AS01.jpg?v=1520377835","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cstrong\u003eThe Fluke 1587 FC Insulation Multimeter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures four powerful new diagnostic functions through the Fluke Connect Measurements app:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePl\/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster\u003c\/li\u003e\n\u003cli\u003eMemory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time\u003c\/li\u003e\n\u003cli\u003eTemperature Compensation through app for establishing accurate baselines and relevant historical comparisons\u003c\/li\u003e\n\u003cli\u003eHistorical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke i400 AC Current Clamp\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-safety current clamp for digital multimeters. The current clamp provides accurate current measurements without breaking electric circuits, helping you take measurements safely with industry standard safety ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 9040 Phase Rotation Indicator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis effective for measuring phase rotation in all areas where three phase supplies are used to feed motors, drives and electrical systems. It allows rapid determination of phase sequence and ideally suited for commercial and industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes a Fluke 1587 FC 2-in-1 Insulation DMM, Fluke i400 Current Clamp, and a Fluke 9040 Phase Rotation Indicator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWith the Fluke 1587 FC, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease\u003c\/li\u003e\n\u003cli\u003eUse the Fluke i400 with your Fluke 1587 FC to accurately measure AC current without breaking the circuit\u003c\/li\u003e\n\u003cli\u003eCheck the rotation of three-phase motors easily and safely with the Fluke 9040\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke 1587 FC 2-in-1 Insulation DMM\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePl\/DAR measurements with TrendIt™ graphs\u003c\/li\u003e\n\u003cli\u003eMemory storage through Fluke Connect Measurements app\u003c\/li\u003e\n\u003cli\u003eTemperature Compensation through Fluke Connect Measurements app\u003c\/li\u003e\n\u003cli\u003eVFD low-pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eInsulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/li\u003e\n\u003cli\u003eInsulation test voltages 500 V, 1000 V\u003c\/li\u003e\n\u003cli\u003eInsulation test: 0.01 MΩ to 2.0 GΩ\u003c\/li\u003e\n\u003cli\u003eInsulation test: 0.1 MΩ to 600 MΩ\u003c\/li\u003e\n\u003cli\u003eAuto-discharge of capacitive voltage\u003c\/li\u003e\n\u003cli\u003eInsulation test smoothing reading\u003c\/li\u003e\n\u003cli\u003eFrequency \/ Capacitance \/ Diode test \/ Temperature\u003c\/li\u003e\n\u003cli\u003eMin\/Max \/ AC\/DC Voltage \/ DC Millivolts \/ AC\/DC Milliamps\u003c\/li\u003e\n\u003cli\u003eResistance (0.1 Ω to 50 MΩ) \/ Continuity \/ Auto power off\u003c\/li\u003e\n\u003cli\u003eThree-year warranty \/ Remote probe, test leads, alligator clips, K-type thermocouple, hard case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke i400 AC Current Clamp\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse with your Fluke 1587 FC to measure 1A AC to 400 A AC\u003c\/li\u003e\n\u003cli\u003e1 mA\/Amp output guarantees easy reading\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V \/ CAT IV 600 V overvoltage rating for added user protection\u003c\/li\u003e\n\u003cli\u003eSpecially designed to offer maximum utility in a very compact shape\u003c\/li\u003e\n\u003cli\u003eMaximum conductor: Ø 32 mm\u003c\/li\u003e\n\u003cli\u003e1 year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 9040 Phase Rotation Indicator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLarge display to easily determine field rotation and phase sequence\u003c\/li\u003e\n\u003cli\u003eIndication for all three phases\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V overvoltage rating\u003c\/li\u003e\n\u003cli\u003e2 year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1587 FC Insulation Multimeter\u003c\/li\u003e\n\u003cli\u003ei400 Current Clamp\u003c\/li\u003e\n\u003cli\u003e9040 Phase Rotation Indicator\u003c\/li\u003e\n\u003cli\u003eRemote Probe\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003cli\u003eAlligator Clips\u003c\/li\u003e\n\u003cli\u003eK-Type Thermocouple\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003cli\u003eUser Documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1587FC.pdf?1805\" target=\"_blank\" title=\"Fluke 1587FC Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1587FC Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e"}
Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit

Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit

$2,133.83 CAD

The Fluke 1587 FC Insulation Multimeter features four powerful new diagnostic functions through the Fluke Connect Measurements app: Pl/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for ...


More Info
Fluke 1555 10kV Digital Insulation Tester

Insulation Testers

From $9,616.55 CAD
{"id":1069130022955,"title":"Fluke 1555 10kV Digital Insulation Tester","handle":"fluke-1555-10kv-insulation-resistance-tester","description":"\u003cp\u003e\u003cspan\u003eEvaluate the trends and eliminate the doubt with this insulation resistance tester. Ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables, the CAT III 1000 V\/CAT IV 600 V safety-rated tester can conduct digital insulation testing up to 10 kV. By adding this to your preventive or predictive maintenance programs, it can help to identify potential equipment failures before they occur.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest voltages to up 10 kV and save time by trending on the spot only with Fluke Connect™\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage (DC)\u003c\/td\u003e\n\u003ctd\u003eRange (DC)\u003c\/td\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e250 kΩ to 5 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 GΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 50 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e500 kΩ to 10 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 GΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 100 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e1 MΩ to 20 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20 GΩ to 200 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 200 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e50 GΩ to 500 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 500 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 MΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e100 GΩ to 1 TΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 1 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 MΩ to 200 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 GΩ to 2 TΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 2 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLeakage Current Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 nA to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (5 % + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCapacitance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 uF to 15.00°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (15 % rdg + 0.03°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eTimer\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 99 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eResolution Setting: 1 minute Indication: 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModel 1555\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eTest Cables with Alligator Clips\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC Power Cord\u003c\/li\u003e\n\u003cli\u003eUsers Manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Installation Guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR Cable Installation Guide\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel 1555\/KIT\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eTest cables with alligator clips (red, black, green)\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC power cord\u003c\/li\u003e\n\u003cli\u003eUser's manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms installation guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR cable installation guide\u003c\/li\u003e\n\u003cli\u003eHeavy duty alligator clip leads\u003c\/li\u003e\n\u003cli\u003eHard Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel 1555FC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eIR3000FC1550 Connector\u003c\/li\u003e\n\u003cli\u003eTest Cables with Alligator Clips\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC Power Cord\u003c\/li\u003e\n\u003cli\u003eUsers Manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Installation Guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR Cable Installation Guide\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1550-1555_Spec.pdf?1595\" target=\"_blank\" title=\"Fluke 1555 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1555 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-03-05T15:57:38-07:00","created_at":"2018-03-05T16:00:01-07:00","vendor":"Fluke","type":"Insulation Testers","tags":[],"price":961655,"price_min":961655,"price_max":1065151,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11001299370027,"title":"1555","option1":"1555","option2":null,"option3":null,"sku":"FLU-1555","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1555 10kV Digital Insulation Tester - 1555","public_title":"1555","options":["1555"],"price":961655,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969550925","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16793619922987,"title":"1555\/KIT","option1":"1555\/KIT","option2":null,"option3":null,"sku":"FLU-1555\/KIT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1555 10kV Digital Insulation Tester - 1555\/KIT","public_title":"1555\/KIT","options":["1555\/KIT"],"price":1065151,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969550970","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16793619955755,"title":"1555 FC","option1":"1555 FC","option2":null,"option3":null,"sku":"FLU-1555FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1555 10kV Digital Insulation Tester - 1555 FC","public_title":"1555 FC","options":["1555 FC"],"price":961655,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969868891","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1555-f5d-1.jpg?v=1520290804"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1555-f5d-1.jpg?v=1520290804","options":["Model"],"media":[{"alt":null,"id":1469096853547,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1555-f5d-1.jpg?v=1520290804"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1555-f5d-1.jpg?v=1520290804","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eEvaluate the trends and eliminate the doubt with this insulation resistance tester. Ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables, the CAT III 1000 V\/CAT IV 600 V safety-rated tester can conduct digital insulation testing up to 10 kV. By adding this to your preventive or predictive maintenance programs, it can help to identify potential equipment failures before they occur.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest voltages to up 10 kV and save time by trending on the spot only with Fluke Connect™\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage (DC)\u003c\/td\u003e\n\u003ctd\u003eRange (DC)\u003c\/td\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e250 kΩ to 5 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 GΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 50 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e500 kΩ to 10 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 GΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 100 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e1 MΩ to 20 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20 GΩ to 200 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 200 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e50 GΩ to 500 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 500 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 MΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e100 GΩ to 1 TΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 1 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 MΩ to 200 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 GΩ to 2 TΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 2 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLeakage Current Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 nA to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (5 % + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCapacitance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 uF to 15.00°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (15 % rdg + 0.03°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eTimer\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 99 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eResolution Setting: 1 minute Indication: 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModel 1555\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eTest Cables with Alligator Clips\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC Power Cord\u003c\/li\u003e\n\u003cli\u003eUsers Manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Installation Guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR Cable Installation Guide\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel 1555\/KIT\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eTest cables with alligator clips (red, black, green)\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC power cord\u003c\/li\u003e\n\u003cli\u003eUser's manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms installation guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR cable installation guide\u003c\/li\u003e\n\u003cli\u003eHeavy duty alligator clip leads\u003c\/li\u003e\n\u003cli\u003eHard Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel 1555FC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eIR3000FC1550 Connector\u003c\/li\u003e\n\u003cli\u003eTest Cables with Alligator Clips\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC Power Cord\u003c\/li\u003e\n\u003cli\u003eUsers Manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Installation Guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR Cable Installation Guide\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1550-1555_Spec.pdf?1595\" target=\"_blank\" title=\"Fluke 1555 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1555 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 1555 10kV Digital Insulation Tester

Fluke 1555 10kV Digital Insulation Tester

$9,616.55 CAD

Evaluate the trends and eliminate the doubt with this insulation resistance tester. Ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables, the CAT III 1000 V/CAT IV 600 V safety-rated tester can conduct digital insulation testing up to 10 kV. By adding this to your preventive or predictive m...


More Info
Fluke 1550C 5kV Digital Insulation Tester

Insulation Testers

From $8,567.99 CAD
{"id":1038411464747,"title":"Fluke 1550C 5kV Digital Insulation Tester","handle":"fluke-1550c-5kv-insulation-resistance-tester","description":"\u003cp\u003e\u003cspan\u003eThe Fluke 1550C performs digital insulation testing up to 5 kV, and makes the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTrust the best name in the business for all your insulation testing with the Fluke 1550C. With advanced testing methods, reporting, and best-in-class performance, this is the number one insulation tester in the industry. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage (DC)\u003c\/td\u003e\n\u003ctd\u003eRange (DC)\u003c\/td\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e250 kΩ to 5 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 GΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 50 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e500 kΩ to 10 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 GΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 100 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e1 MΩ to 20 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20 GΩ to 200 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 200 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e50 GΩ to 500 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 500 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 MΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e100 GΩ to 1 TΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 1 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLeakage Current Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 nA to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (5 % + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCapacitance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 uF to 15.00°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (15 % rdg + 0.03°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest cables with alligator clips (red, black, green)\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC power cord\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eEnglish manual\u003c\/li\u003e\n\u003cli\u003eUser's manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eQuick reference card\u003c\/li\u003e\n\u003cli\u003eSoftware license agreement\u003c\/li\u003e\n\u003cli\u003eRegistration card\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms installation guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR cable installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1550-1555_Spec.pdf?1595\" target=\"_blank\" title=\"Fluke 1550C Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1550C Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-02-21T14:50:18-07:00","created_at":"2018-02-21T14:54:58-07:00","vendor":"Fluke","type":"Insulation Testers","tags":[],"price":856799,"price_min":856799,"price_max":943295,"available":true,"price_varies":true,"compare_at_price":653300,"compare_at_price_min":653300,"compare_at_price_max":653300,"compare_at_price_varies":false,"variants":[{"id":10706613174315,"title":"1550C","option1":"1550C","option2":null,"option3":null,"sku":"FLU-1550C","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1550C 5kV Digital Insulation Tester - 1550C","public_title":"1550C","options":["1550C"],"price":856799,"weight":6804,"compare_at_price":653300,"inventory_management":"shopify","barcode":"095969550918","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16793563627563,"title":"1550C\/KIT","option1":"1550C\/KIT","option2":null,"option3":null,"sku":"FLU-1550C\/KIT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1550C 5kV Digital Insulation Tester - 1550C\/KIT","public_title":"1550C\/KIT","options":["1550C\/KIT"],"price":943295,"weight":6804,"compare_at_price":653300,"inventory_management":"shopify","barcode":"095969550987","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16793569198123,"title":"1550C FC","option1":"1550C FC","option2":null,"option3":null,"sku":"FLU-1550C FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1550C 5kV Digital Insulation Tester - 1550C FC","public_title":"1550C FC","options":["1550C FC"],"price":872167,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969868785","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C.jpg?v=1562783826","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C_BHD.jpg?v=1562783826","\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-1550c-01b-s.jpg?v=1562783826"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C.jpg?v=1562783826","options":["Model"],"media":[{"alt":null,"id":2797304807467,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C.jpg?v=1562783826"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C.jpg?v=1562783826","width":800},{"alt":null,"id":1417403858987,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C_BHD.jpg?v=1562783826"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C_BHD.jpg?v=1562783826","width":1200},{"alt":null,"id":1417412182059,"position":3,"preview_image":{"aspect_ratio":1.493,"height":402,"width":600,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-1550c-01b-s.jpg?v=1562783826"},"aspect_ratio":1.493,"height":402,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-1550c-01b-s.jpg?v=1562783826","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Fluke 1550C performs digital insulation testing up to 5 kV, and makes the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTrust the best name in the business for all your insulation testing with the Fluke 1550C. With advanced testing methods, reporting, and best-in-class performance, this is the number one insulation tester in the industry. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage (DC)\u003c\/td\u003e\n\u003ctd\u003eRange (DC)\u003c\/td\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e250 kΩ to 5 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 GΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 50 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e500 kΩ to 10 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 GΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 100 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e1 MΩ to 20 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20 GΩ to 200 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 200 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e50 GΩ to 500 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 500 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 MΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e100 GΩ to 1 TΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 1 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLeakage Current Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 nA to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (5 % + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCapacitance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 uF to 15.00°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (15 % rdg + 0.03°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest cables with alligator clips (red, black, green)\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC power cord\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eEnglish manual\u003c\/li\u003e\n\u003cli\u003eUser's manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eQuick reference card\u003c\/li\u003e\n\u003cli\u003eSoftware license agreement\u003c\/li\u003e\n\u003cli\u003eRegistration card\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms installation guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR cable installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1550-1555_Spec.pdf?1595\" target=\"_blank\" title=\"Fluke 1550C Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1550C Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 1550C 5kV Digital Insulation Tester

Fluke 1550C 5kV Digital Insulation Tester

$8,721.67 CAD

The Fluke 1550C performs digital insulation testing up to 5 kV, and makes the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur.  Trust the best name in the business for all your insulation testing with the Fluke 1550C. With advanced testing methods, reporting, and ...


More Info