{ "id":1263017984043, "title":"Megger MIT515 5kV Insulation Tester","handle":"megger-mit515-5kv-insulation-tester", "description":"\u003cp\u003eThe MIT515 is the simplest of Megger's new range of small light 5 kV insulation resistance testers for the testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustry best guard terminal accuracy\u003c\/li\u003e\n\u003cli\u003eSmaller size and lightweight allows easier transport and use without compromising performance\u003c\/li\u003e\n\u003cli\u003eCompact and lightweight for easy transport and use\u003c\/li\u003e\n\u003cli\u003eAuto IR, DAR and PI\u003c\/li\u003e\n\u003cli\u003eUnique dual case design provides additional user protection\u003c\/li\u003e\n\u003cli\u003eLithium-ion battery - extended capacity, rapid charge\u003c\/li\u003e\n\u003cli\u003eAdvanced memory with time\/date stamp\u003c\/li\u003e\n\u003cli\u003eCATIV 600V safety rating on all terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTesting the Insulation of High or Low Voltage Electric Equipment\u003c\/li\u003e\n\u003cli\u003eGenerators\u003c\/li\u003e\n\u003cli\u003eMotors\u003c\/li\u003e\n\u003cli\u003eTransformers\u003c\/li\u003e\n\u003cli\u003eCables\u003c\/li\u003e\n\u003cli\u003eSwitchgear\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage Power Cables\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage Buses\u003c\/li\u003e\n\u003cli\u003eLarge Motor\/Generator Windings\u003c\/li\u003e\n\u003cli\u003eLine and Substation Transformers\u003c\/li\u003e\n\u003cli\u003eSpot Tests\u003c\/li\u003e\n\u003cli\u003eStepvoltage Tests\u003c\/li\u003e\n\u003cli\u003eDielectric Discharge Tests\u003c\/li\u003e\n\u003cli\u003eRamp Tests\u003c\/li\u003e\n\u003cli\u003eDielectric Absorption Tests\u003c\/li\u003e\n\u003cli\u003eAcceptance Testing at Installation to Check Conformance to Specifications\u003c\/li\u003e\n\u003cli\u003eRoutine Preventive\/Predictive Maintenance Testing After Installation\u003c\/li\u003e\n\u003cli\u003eQA Testing as Part of the Manufacturing Process\u003c\/li\u003e\n\u003cli\u003eDiagnostic Testing to Isolate Faulty Components for Repair\u003c\/li\u003e\n\u003cli\u003eRotating Machinery\u003c\/li\u003e\n\u003cli\u003eInsulation Resistance of Armature and Field Windings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Insulation Range\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Insulation Range\u003c\/td\u003e\n\u003ctd\u003e10 kΩ to 10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Voltages\u003c\/td\u003e\n\u003ctd\u003e250 V, 500 V, 1000 V, 2500 V, and 5000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Defined Test Voltages\u003c\/td\u003e\n\u003ctd\u003e100 V to 1 kV in 10 V Steps\u003cbr\u003e1 kV to 5 kV in 25 V Steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (23°C)\u003c\/td\u003e\n\u003ctd\u003e±5% to 1 TΩ, ±20% to 10 TΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Accuracy (0 to 30°C)\u003c\/td\u003e\n\u003ctd\u003e4 to 0% ±10 V of nominal test voltage at 1 GΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltmeter Range\u003c\/td\u003e\n\u003ctd\u003e30 to 660 V ac or dc, 50\/60 Hz\u003cbr\u003eAccuracy: ±3% ±3 V\u003cbr\u003eFrequency Range: 45 Hz to 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Current\u003c\/td\u003e\n\u003ctd\u003e3 mA Nominal, Max. Power on All Loads Outperforming Many\u003cbr\u003e5 mA Testers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Alarm\u003c\/td\u003e\n\u003ctd\u003e100 kΩ to 1 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Measurement\u003c\/td\u003e\n\u003ctd\u003eRange: 0.01 nA to 6 mA\u003cbr\u003eAccuracy: ±5% ±0.2 nA at All Voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance Range Above 500 V\u003c\/td\u003e\n\u003ctd\u003e10 nF to 25 µF (Dependent on Measurement Voltage)\u003cbr\u003eAccuracy (23°C): ±10% ±5 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Charge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3 s per µF at 3 mA to 5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Discharge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;250 ms\/µF to Discharge from 5000 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Range\u003c\/td\u003e\n\u003ctd\u003eUp to 99 Minutes, 15 Seconds Minimum Setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e5 1\/2 Hours Continuous Logging Every 5 Seconds or 33 Logged PI Tests or 350 Logged IR Tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustry-Standard Tests\u003c\/td\u003e\n\u003ctd\u003eIR, IR(t), DAR, PI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eUSB Type B (Device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal Time Output\u003c\/td\u003e\n\u003ctd\u003eUSB, 1 Reading\/Second (Voltage, Current and Resistance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterference Rejection\u003c\/td\u003e\n\u003ctd\u003e1 mA per 250 V up to a maximum of 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuard Terminal\u003c\/td\u003e\n\u003ctd\u003e2% Error Guarding 500 kΩ Leakage with 100 mΩ Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Range\u003c\/td\u003e\n\u003ctd\u003e85 to 265 V, 50\/60 Hz, 60 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eLithium-Ion, 11.1 V, 5.2 A Hour, Meets IEC 62133:2003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eTypical Capacity 6 Hours Continuous at 5 kV with a 100 MW Load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Charge Time\u003c\/td\u003e\n\u003ctd\u003e2.5 Hours from Deep Discharge, 2 Hours Normal Discharge\u003cbr\u003e30 Minutes Quick Charge: 1 Hour Operation at 5 kV, 100 MW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eMeets the Requirements of IEC61010-1 CAT IV 600 V\u003cbr\u003eDefault Voltmeter Warns Operator of Applied Voltage Above 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eMeets the requirements of IEC61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP65 (Lid Closed)\u003cbr\u003eIP40 (Lid Open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003eOperating: -4 to 122°F (-20 to 50°C)\u003cbr\u003eStorage: -13 to 149°F (-25 to 65°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e90% RH @ 104°F (40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e3000 m, CAT rating maintained \u0026gt;2000 m* (*test load connected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12 x 11 x 7\" (315 x 285 x 181 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 lb (4.5 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMegohmmeter\u003c\/li\u003e\n\u003cli\u003eUser Guide CD-ROM\u003c\/li\u003e\n\u003cli\u003ePower Lead\u003c\/li\u003e\n\u003cli\u003e3 x 3m Lead Set, Medium Insulated Clips (5 kV,10 kV)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/MIT515_525_1025_specs.pdf?1591\" target=\"_blank\" title=\"Megger MIT515 Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger MIT515 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-05-16T12:54:00", "created_at":"2018-05-16T13:23:33", "vendor":"Megger", "type":"Insulation Testers", "tags":[], "price":617000, "price_min":617000, "price_max":617000, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[12140920143915], "variants":[{ "id":12140920143915, "product_id":1263017984043, "product_handle":"megger-mit515-5kv-insulation-tester", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"MEG-MIT515-US", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Megger MIT515 5kV Insulation Tester - Default Title", "options":["Default Title"], "price":617000, "weight":3175, "compare_at_price":null, "inventory_quantity":2, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":2, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":""}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit525-882-1.jpg?v=1526498615"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/megger-mit525-882-1.jpg?v=1526498615", "options":["Title"], "url":"\/products\/megger-mit515-5kv-insulation-tester"}
Megger MIT515 5kV Insulation Tester
Product Description
The MIT515 is the simplest of Megger's new range of small light 5 kV insulation resistance testers for the testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store.
Sku: MEG-MIT515-US
Vendor: Megger
2 left in stock.
Overview
Features
- Industry best guard terminal accuracy
- Smaller size and lightweight allows easier transport and use without compromising performance
- Compact and lightweight for easy transport and use
- Auto IR, DAR and PI
- Unique dual case design provides additional user protection
- Lithium-ion battery - extended capacity, rapid charge
- Advanced memory with time/date stamp
- CATIV 600V safety rating on all terminals
Applications
- Testing the Insulation of High or Low Voltage Electric Equipment
- Generators
- Motors
- Transformers
- Cables
- Switchgear
- High-Voltage Power Cables
- High-Voltage Buses
- Large Motor/Generator Windings
- Line and Substation Transformers
- Spot Tests
- Stepvoltage Tests
- Dielectric Discharge Tests
- Ramp Tests
- Dielectric Absorption Tests
- Acceptance Testing at Installation to Check Conformance to Specifications
- Routine Preventive/Predictive Maintenance Testing After Installation
- QA Testing as Part of the Manufacturing Process
- Diagnostic Testing to Isolate Faulty Components for Repair
- Rotating Machinery
- Insulation Resistance of Armature and Field Windings
Specifications
Analog Insulation Range | 100 kΩ to 10 TΩ |
Digital Insulation Range | 10 kΩ to 10 TΩ |
Test Voltages | 250 V, 500 V, 1000 V, 2500 V, and 5000 V |
User Defined Test Voltages | 100 V to 1 kV in 10 V Steps 1 kV to 5 kV in 25 V Steps |
Accuracy (23°C) | ±5% to 1 TΩ, ±20% to 10 TΩ |
Voltage Output Accuracy (0 to 30°C) | 4 to 0% ±10 V of nominal test voltage at 1 GΩ load |
Voltmeter Range | 30 to 660 V ac or dc, 50/60 Hz Accuracy: ±3% ±3 V Frequency Range: 45 Hz to 65 Hz |
Short Circuit Current | 3 mA Nominal, Max. Power on All Loads Outperforming Many 5 mA Testers |
Insulation Alarm | 100 kΩ to 1 GΩ |
Current Measurement | Range: 0.01 nA to 6 mA Accuracy: ±5% ±0.2 nA at All Voltages |
Capacitance Range Above 500 V | 10 nF to 25 µF (Dependent on Measurement Voltage) Accuracy (23°C): ±10% ±5 nF |
Capacitor Charge | <3 s per µF at 3 mA to 5 kV |
Capacitor Discharge | <250 ms/µF to Discharge from 5000 V to 50 V |
Timer Range | Up to 99 Minutes, 15 Seconds Minimum Setting |
Memory Capacity | 5 1/2 Hours Continuous Logging Every 5 Seconds or 33 Logged PI Tests or 350 Logged IR Tests |
Industry-Standard Tests | IR, IR(t), DAR, PI |
Interface | USB Type B (Device) |
Real Time Output | USB, 1 Reading/Second (Voltage, Current and Resistance) |
Interference Rejection | 1 mA per 250 V up to a maximum of 3 mA |
Guard Terminal | 2% Error Guarding 500 kΩ Leakage with 100 mΩ Load |
Voltage Input Range | 85 to 265 V, 50/60 Hz, 60 VA |
Battery Type | Lithium-Ion, 11.1 V, 5.2 A Hour, Meets IEC 62133:2003 |
Battery Life | Typical Capacity 6 Hours Continuous at 5 kV with a 100 MW Load |
Battery Charge Time | 2.5 Hours from Deep Discharge, 2 Hours Normal Discharge 30 Minutes Quick Charge: 1 Hour Operation at 5 kV, 100 MW |
Safety | Meets the Requirements of IEC61010-1 CAT IV 600 V Default Voltmeter Warns Operator of Applied Voltage Above 50 V |
EMC | Meets the requirements of IEC61326-1 |
Ingress Protection | IP65 (Lid Closed) IP40 (Lid Open) |
Temperature Range | Operating: -4 to 122°F (-20 to 50°C) Storage: -13 to 149°F (-25 to 65°C) |
Humidity Range | 90% RH @ 104°F (40°C) |
Altitude | 3000 m, CAT rating maintained >2000 m* (*test load connected) |
Dimensions | 12 x 11 x 7" (315 x 285 x 181 mm) |
Weight | 10 lb (4.5 kg) |
What's in the Box
- Megohmmeter
- User Guide CD-ROM
- Power Lead
- 3 x 3m Lead Set, Medium Insulated Clips (5 kV,10 kV)
Resources
Related Products
Megger MIT2500 2.5kV Insulation Tester
$2,130.00 CAD
Fluke 1503 Insulation Resistance Tester
$990.07 CAD
AEMC 6529 Megohmmeter, 1000V
$489.00 CAD
AEMC 6528 Megohmmeter, 1000V
$419.00 CAD