fluke

Fluke 107 Palm-Sized Multimeter, 600V

Multimeters

$213.71 CAD
{"id":4512157171785,"title":"Fluke 107 Palm-Sized Multimeter, 600V","handle":"fluke-107-palm-sized-multimeter-600v","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 107 is a compact, easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool: small enough to fit in a shirt pocket or work bag, tough enough to withstand daily use, and extremely simple to use. All without compromising safety. For everyday applications, where True-RMS accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"PrdPlainText\"\u003eAlso check out the Fluke 115 Electrical Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117 Electrician’s Multimeter with Non-contact voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch3\u003eFluke 107 Complete test functions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC and DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eAC and DC current measurement\u003c\/li\u003e\n\u003cli\u003eResistance measurement\u003c\/li\u003e\n\u003cli\u003eCapacitance measurement\u003c\/li\u003e\n\u003cli\u003eDiode measurement\u003c\/li\u003e\n\u003cli\u003eFrequency and duty cycle test and other functions to meet basic electrical maintenance, electrical measurement, and electronic measurement applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eErgonomic and Rugged\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComfortable grip, only weighs 200g and easy to carry\u003c\/li\u003e\n\u003cli\u003eRugged enclosure and 1-meter drop test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFluke 107 Additional Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFull-parameter automatic range test, which is convenient and quick to test; at the same time, it reduces the number of rotations of the wave plate and prolongs the life of the instrument.\u003c\/li\u003e\n\u003cli\u003e6000-word large screen LCD backlight display\u003c\/li\u003e\n\u003cli\u003eBattery powered, automatic power save mode\u003c\/li\u003e\n\u003cli\u003eData retention feature makes it easier to read measurement results\u003c\/li\u003e\n\u003cli\u003eComes with SmartStrap™ intelligent magnetic multi-purpose lanyard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003ePrecision specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"2\"\u003e\u003cstrong\u003eAC voltage\u003cbr\u003e(40 Hz to 500 Hz)\u003csup\u003e1\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6.000 V\u003cbr\u003e60.00 V\u003cbr\u003e600.0 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003cbr\u003e0.01 V\u003cbr\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e1.0 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V\u003cbr\u003e60.00 V\u003cbr\u003e600.0 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003cbr\u003e0.01 V\u003cbr\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e0.5 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eExchange millivolts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003ctd\u003e3.0 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDiode test\u003csup\u003e2\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.000 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003ctd\u003e10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResistance\u003cbr\u003e(ohm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω\u003cbr\u003e4.000 kΩ\u003cbr\u003e40.00 kΩ\u003cbr\u003e400.0 kΩ\u003cbr\u003e4.000 MΩ\u003cbr\u003e40.00 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003cbr\u003e0.001 kΩ\u003cbr\u003e0.01 kΩ\u003cbr\u003e0.1 kΩ\u003cbr\u003e0.001 MΩ\u003cbr\u003e0.01 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.5 % + 3\u003cbr\u003e0.5 % + 2\u003cbr\u003e0.5 % + 2\u003cbr\u003e0.5 % + 2\u003cbr\u003e0.5 % + 2\u003cbr\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCapacitor\u003csup\u003e3\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.00 nF\u003cbr\u003e500.0 nF\u003cbr\u003e5.000 μF\u003cbr\u003e50.00 μF\u003cbr\u003e500.0 μF\u003cbr\u003e1000 μF\u003c\/td\u003e\n\u003ctd\u003e0.01 nF\u003cbr\u003e0.1 nF\u003cbr\u003e0.001 μF\u003cbr\u003e0.01 μF\u003cbr\u003e0.1 μF\u003cbr\u003e1 μF\u003c\/td\u003e\n\u003ctd\u003e2 % + 5\u003cbr\u003e2 % + 5\u003cbr\u003e5 % + 5\u003cbr\u003e5 % + 5\u003cbr\u003e5 % + 5\u003cbr\u003e5 % + 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFrequency\u003csup\u003e4\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHz\u003cbr\u003e(10 Hz – 100 kHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.00 Hz\u003cbr\u003e500.0 Hz\u003cbr\u003e5.000 kHz\u003cbr\u003e50.00 kHz\u003cbr\u003e100.0 kHz\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003cbr\u003e0.1 Hz\u003cbr\u003e0.001 kHz\u003cbr\u003e0.01 kHz\u003cbr\u003e0.1 kHz\u003c\/td\u003e\n\u003ctd\u003e0.1 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDuty cycle\u003csup\u003e4\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 % to 99 %\u003c\/td\u003e\n\u003ctd\u003e0.10 %\u003c\/td\u003e\n\u003ctd\u003e1 % typical case\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAC current\u003cbr\u003e(40 Hz - 200 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.000 A\u003cbr\u003e10.00 A\u003c\/td\u003e\n\u003ctd\u003e0.001 A\u003cbr\u003e0.01 A\u003c\/td\u003e\n\u003ctd\u003e1.5 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.000 A\u003cbr\u003e10.00 A\u003c\/td\u003e\n\u003ctd\u003e0.001 A\u003cbr\u003e0.01 A\u003c\/td\u003e\n\u003ctd\u003e1.5 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2 class=\"hidden\"\u003e\u003c\/h2\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 107 Palm-sized, CAT III Digital Multimeter\u003c\/li\u003e\n\u003cli\u003eTL75 Hard Point™ Test Lead Set\u003c\/li\u003e\n\u003cli\u003eTwo AAA batteries (installed)\u003c\/li\u003e\n\u003cli\u003eSmartStrap™ intelligent magnetic multi-purpose lanyard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_107_Palm-Sized_Multimeter_Spec_Sheet.pdf?v=1594235733\" target=\"_blank\" title=\"Fluke 107 Multimeter Spec sheet\" rel=\"noopener noreferrer\"\u003eFluke 107 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2020-07-08T13:10:41-06:00","created_at":"2020-07-08T13:10:41-06:00","vendor":"Fluke","type":"Multimeters","tags":[],"price":21371,"price_min":21371,"price_max":21371,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":31682510651465,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-107","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 107 Palm-Sized Multimeter, 600V","public_title":null,"options":["Default Title"],"price":21371,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969678780","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke107Pic1.jpg?v=1594235698","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke107Pic2.jpg?v=1594235698"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke107Pic1.jpg?v=1594235698","options":["Title"],"media":[{"alt":null,"id":6415348105289,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke107Pic1.jpg?v=1594235698"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke107Pic1.jpg?v=1594235698","width":1024},{"alt":null,"id":6415348138057,"position":2,"preview_image":{"aspect_ratio":1.0,"height":700,"width":700,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke107Pic2.jpg?v=1594235698"},"aspect_ratio":1.0,"height":700,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke107Pic2.jpg?v=1594235698","width":700}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 107 is a compact, easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool: small enough to fit in a shirt pocket or work bag, tough enough to withstand daily use, and extremely simple to use. All without compromising safety. For everyday applications, where True-RMS accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"PrdPlainText\"\u003eAlso check out the Fluke 115 Electrical Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117 Electrician’s Multimeter with Non-contact voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003ch3\u003eFluke 107 Complete test functions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAC and DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eAC and DC current measurement\u003c\/li\u003e\n\u003cli\u003eResistance measurement\u003c\/li\u003e\n\u003cli\u003eCapacitance measurement\u003c\/li\u003e\n\u003cli\u003eDiode measurement\u003c\/li\u003e\n\u003cli\u003eFrequency and duty cycle test and other functions to meet basic electrical maintenance, electrical measurement, and electronic measurement applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eErgonomic and Rugged\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eComfortable grip, only weighs 200g and easy to carry\u003c\/li\u003e\n\u003cli\u003eRugged enclosure and 1-meter drop test\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFluke 107 Additional Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFull-parameter automatic range test, which is convenient and quick to test; at the same time, it reduces the number of rotations of the wave plate and prolongs the life of the instrument.\u003c\/li\u003e\n\u003cli\u003e6000-word large screen LCD backlight display\u003c\/li\u003e\n\u003cli\u003eBattery powered, automatic power save mode\u003c\/li\u003e\n\u003cli\u003eData retention feature makes it easier to read measurement results\u003c\/li\u003e\n\u003cli\u003eComes with SmartStrap™ intelligent magnetic multi-purpose lanyard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003ePrecision specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" rowspan=\"2\"\u003e\u003cstrong\u003eAC voltage\u003cbr\u003e(40 Hz to 500 Hz)\u003csup\u003e1\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6.000 V\u003cbr\u003e60.00 V\u003cbr\u003e600.0 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003cbr\u003e0.01 V\u003cbr\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e1.0 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V\u003cbr\u003e60.00 V\u003cbr\u003e600.0 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003cbr\u003e0.01 V\u003cbr\u003e0.1 V\u003c\/td\u003e\n\u003ctd\u003e0.5 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eExchange millivolts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003ctd\u003e3.0 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDiode test\u003csup\u003e2\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.000 V\u003c\/td\u003e\n\u003ctd\u003e0.001 V\u003c\/td\u003e\n\u003ctd\u003e10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eResistance\u003cbr\u003e(ohm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400.0 Ω\u003cbr\u003e4.000 kΩ\u003cbr\u003e40.00 kΩ\u003cbr\u003e400.0 kΩ\u003cbr\u003e4.000 MΩ\u003cbr\u003e40.00 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003cbr\u003e0.001 kΩ\u003cbr\u003e0.01 kΩ\u003cbr\u003e0.1 kΩ\u003cbr\u003e0.001 MΩ\u003cbr\u003e0.01 MΩ\u003c\/td\u003e\n\u003ctd\u003e0.5 % + 3\u003cbr\u003e0.5 % + 2\u003cbr\u003e0.5 % + 2\u003cbr\u003e0.5 % + 2\u003cbr\u003e0.5 % + 2\u003cbr\u003e1.5% + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eCapacitor\u003csup\u003e3\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.00 nF\u003cbr\u003e500.0 nF\u003cbr\u003e5.000 μF\u003cbr\u003e50.00 μF\u003cbr\u003e500.0 μF\u003cbr\u003e1000 μF\u003c\/td\u003e\n\u003ctd\u003e0.01 nF\u003cbr\u003e0.1 nF\u003cbr\u003e0.001 μF\u003cbr\u003e0.01 μF\u003cbr\u003e0.1 μF\u003cbr\u003e1 μF\u003c\/td\u003e\n\u003ctd\u003e2 % + 5\u003cbr\u003e2 % + 5\u003cbr\u003e5 % + 5\u003cbr\u003e5 % + 5\u003cbr\u003e5 % + 5\u003cbr\u003e5 % + 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eFrequency\u003csup\u003e4\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eHz\u003cbr\u003e(10 Hz – 100 kHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50.00 Hz\u003cbr\u003e500.0 Hz\u003cbr\u003e5.000 kHz\u003cbr\u003e50.00 kHz\u003cbr\u003e100.0 kHz\u003c\/td\u003e\n\u003ctd\u003e0.01 Hz\u003cbr\u003e0.1 Hz\u003cbr\u003e0.001 kHz\u003cbr\u003e0.01 kHz\u003cbr\u003e0.1 kHz\u003c\/td\u003e\n\u003ctd\u003e0.1 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDuty cycle\u003csup\u003e4\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 % to 99 %\u003c\/td\u003e\n\u003ctd\u003e0.10 %\u003c\/td\u003e\n\u003ctd\u003e1 % typical case\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAC current\u003cbr\u003e(40 Hz - 200 Hz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.000 A\u003cbr\u003e10.00 A\u003c\/td\u003e\n\u003ctd\u003e0.001 A\u003cbr\u003e0.01 A\u003c\/td\u003e\n\u003ctd\u003e1.5 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eDC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.000 A\u003cbr\u003e10.00 A\u003c\/td\u003e\n\u003ctd\u003e0.001 A\u003cbr\u003e0.01 A\u003c\/td\u003e\n\u003ctd\u003e1.5 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2 class=\"hidden\"\u003e\u003c\/h2\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 107 Palm-sized, CAT III Digital Multimeter\u003c\/li\u003e\n\u003cli\u003eTL75 Hard Point™ Test Lead Set\u003c\/li\u003e\n\u003cli\u003eTwo AAA batteries (installed)\u003c\/li\u003e\n\u003cli\u003eSmartStrap™ intelligent magnetic multi-purpose lanyard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_107_Palm-Sized_Multimeter_Spec_Sheet.pdf?v=1594235733\" target=\"_blank\" title=\"Fluke 107 Multimeter Spec sheet\" rel=\"noopener noreferrer\"\u003eFluke 107 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e"}
Fluke 107 Palm-Sized Multimeter, 600V

Fluke 107 Palm-Sized Multimeter, 600V

$213.71 CAD

The Fluke 107 is a compact, easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool: small enough to fit in a shirt pocket or work bag, tough enough to withstand daily use, and extremely simple to use. All without compromising safety. For everyday applications, where True-RMS accuracy isn’t...


More Info
Fluke 113 Utility Multimeter

Multimeters

$241.11 CAD
{"id":1038124089387,"title":"Fluke 113 Utility Multimeter","handle":"fluke-113-utility-multimeter","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe Fluke 113 has significant improvements over other basic digital multimeters available on the market. Using the Fluke VCHEK™ LoZ low impedance measurement function, users can simultaneously test for voltage or continuity. The Min\/Max function lets you record signal fluctuations. The Fluke 113 can also perform diode tests, and provides both auto and manual ranging capabilities.\u003c\/span\u003e\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul class=\"PrdPlainText\"\u003e\n\u003cli\u003e\n\u003cspan\u003eVCHEK™ LoZ low impedance measurement function to simultaneously test for voltage or continuity\u003c\/span\u003eTrue-rms for accurate ac measurements on non-linear loads\u003c\/li\u003e\n\u003cli\u003eA large backlit display allows for easy visibility in low-lit areas\u003c\/li\u003e\n\u003cli\u003eRecord signal fluctuations using the Min\/Max function\u003c\/li\u003e\n\u003cli\u003eDiode test for testing general-purpose germanium, silicon, and power diodes\u003c\/li\u003e\n\u003cli\u003eIntegral holster with probe holders for easy storage\u003c\/li\u003e\n\u003cli\u003eAuto and Manual ranging for added user functionality\u003c\/li\u003e\n\u003cli\u003eMeets Measurement Category CAT III 600 V and Category IV 300 V standards for a higher level of safety\u003c\/li\u003e\n\u003cli\u003eThe optional TPAK magnetic hanger allows the user hands-free flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"650\" bordercolor=\"#c5cdd2\" border=\"1\" cellspacing=\"0\" cellpadding=\"4\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecItem\"\u003eVCHEK\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1,2,3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"PrdSpecItem\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bodybold\"\u003eRange\u003c\/td\u003e\n\u003ctd\u003e 6.000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 60.00 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.01 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003cb\u003eDC, 45 to 500 Hz\u003c\/b\u003e:2.0 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003cb\u003e500 Hz to 1 kHz\u003c\/b\u003e: 4.0 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecItem\"\u003eDiode test\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"PrdSpecItem\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bodybold\"\u003eRange\u003c\/td\u003e\n\u003ctd\u003e 2.000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e 2.0 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecItem\"\u003eContinuity\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"PrdSpecItem\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e Beeper on \u0026lt; 20 Ω, off \u0026gt; 250 Ω; detects opens or shorts of 500 μs or longer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecItem\"\u003eΩ\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"PrdSpecItem\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bodybold\"\u003eRange\u003c\/td\u003e\n\u003ctd\u003e 600.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 6.000 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 60.00 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.001 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e 0.9 % + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.9 % + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.9 % + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecItem\"\u003eCapacitance\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"PrdSpecItem\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bodybold\"\u003eRange\u003c\/td\u003e\n\u003ctd\u003e 1000 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 10.00 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 100.0 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 9999 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e 1 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.01 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.1 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 1 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e 1.9 % + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 1.9 % + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 1.9 % + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 100 μF - 1000 μF: 1.9 % + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e \u0026gt; 1000 μF: 5 % + 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 113 Multimeter\u003c\/li\u003e\n\u003cli\u003eTL75 Test Leads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_113_Data_Sheet.PDF?1791\" target=\"_blank\" title=\"Fluke 113 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 113 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-02-21T13:32:35-07:00","created_at":"2018-02-21T13:35:03-07:00","vendor":"Fluke","type":"Multimeters","tags":[],"price":24111,"price_min":24111,"price_max":24111,"available":true,"price_varies":false,"compare_at_price":18700,"compare_at_price_min":18700,"compare_at_price_max":18700,"compare_at_price_varies":false,"variants":[{"id":10705464492075,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-113","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 113 Utility Multimeter","public_title":null,"options":["Default Title"],"price":24111,"weight":1814,"compare_at_price":18700,"inventory_management":"shopify","barcode":"095969434522","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/71QusAsBb3L._SL1500.jpg?v=1519245305"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/71QusAsBb3L._SL1500.jpg?v=1519245305","options":["Title"],"media":[{"alt":null,"id":1417067233323,"position":1,"preview_image":{"aspect_ratio":0.714,"height":1500,"width":1071,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/71QusAsBb3L._SL1500.jpg?v=1519245305"},"aspect_ratio":0.714,"height":1500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/71QusAsBb3L._SL1500.jpg?v=1519245305","width":1071}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe Fluke 113 has significant improvements over other basic digital multimeters available on the market. Using the Fluke VCHEK™ LoZ low impedance measurement function, users can simultaneously test for voltage or continuity. The Min\/Max function lets you record signal fluctuations. The Fluke 113 can also perform diode tests, and provides both auto and manual ranging capabilities.\u003c\/span\u003e\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul class=\"PrdPlainText\"\u003e\n\u003cli\u003e\n\u003cspan\u003eVCHEK™ LoZ low impedance measurement function to simultaneously test for voltage or continuity\u003c\/span\u003eTrue-rms for accurate ac measurements on non-linear loads\u003c\/li\u003e\n\u003cli\u003eA large backlit display allows for easy visibility in low-lit areas\u003c\/li\u003e\n\u003cli\u003eRecord signal fluctuations using the Min\/Max function\u003c\/li\u003e\n\u003cli\u003eDiode test for testing general-purpose germanium, silicon, and power diodes\u003c\/li\u003e\n\u003cli\u003eIntegral holster with probe holders for easy storage\u003c\/li\u003e\n\u003cli\u003eAuto and Manual ranging for added user functionality\u003c\/li\u003e\n\u003cli\u003eMeets Measurement Category CAT III 600 V and Category IV 300 V standards for a higher level of safety\u003c\/li\u003e\n\u003cli\u003eThe optional TPAK magnetic hanger allows the user hands-free flexibility\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"650\" bordercolor=\"#c5cdd2\" border=\"1\" cellspacing=\"0\" cellpadding=\"4\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecItem\"\u003eVCHEK\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e1,2,3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"PrdSpecItem\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bodybold\"\u003eRange\u003c\/td\u003e\n\u003ctd\u003e 6.000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 60.00 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.01 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003cb\u003eDC, 45 to 500 Hz\u003c\/b\u003e:2.0 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003cb\u003e500 Hz to 1 kHz\u003c\/b\u003e: 4.0 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecItem\"\u003eDiode test\u003cspan\u003e \u003c\/span\u003e\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"PrdSpecItem\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bodybold\"\u003eRange\u003c\/td\u003e\n\u003ctd\u003e 2.000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e 2.0 % + 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecItem\"\u003eContinuity\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"PrdSpecItem\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e Beeper on \u0026lt; 20 Ω, off \u0026gt; 250 Ω; detects opens or shorts of 500 μs or longer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecItem\"\u003eΩ\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"PrdSpecItem\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bodybold\"\u003eRange\u003c\/td\u003e\n\u003ctd\u003e 600.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 6.000 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 60.00 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.001 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e 0.9 % + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.9 % + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.9 % + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecItem\"\u003eCapacitance\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd class=\"PrdSpecItem\"\u003e\n\u003ctable border=\"0\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"bodybold\"\u003eRange\u003c\/td\u003e\n\u003ctd\u003e 1000 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 10.00 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 100.0 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 9999 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e 1 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.01 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.1 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 1 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e 1.9 % + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 1.9 % + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 1.9 % + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e 100 μF - 1000 μF: 1.9 % + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"PrdSpecSubject\"\u003e\u003c\/td\u003e\n\u003ctd\u003e \u0026gt; 1000 μF: 5 % + 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 113 Multimeter\u003c\/li\u003e\n\u003cli\u003eTL75 Test Leads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_113_Data_Sheet.PDF?1791\" target=\"_blank\" title=\"Fluke 113 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 113 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 113 Utility Multimeter

Fluke 113 Utility Multimeter

$241.11 CAD

The Fluke 113 has significant improvements over other basic digital multimeters available on the market. Using the Fluke VCHEK™ LoZ low impedance measurement function, users can simultaneously test for voltage or continuity. The Min/Max function lets you record signal fluctuations. The Fluke 113 can also perform diode tests, and provides both au...


More Info
{"id":1037892452395,"title":"Fluke 114\/EFSP Electrical Multimeter, 600V","handle":"fluke-114-efsp-electrical-multimeter","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan class=\"PrdPlainText\"\u003eCompact 600 V true-RMS meter for electrical troubleshooting. The Fluke 114 is the troubleshooting tool for “go\/no-go” testing and includes a feature to prevent false readings caused by ghost voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"PrdPlainText\"\u003eAlso check out the Fluke 115 Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117 Electrician’s Multimeter with Non-contact voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul class=\"PrdPlainText\"\u003e\n\u003cli\u003eAutoVolt: automatic ac\/dc voltage selection\u003c\/li\u003e\n\u003cli\u003eLarge white LED back light to work in poorly lit areas\u003c\/li\u003e\n\u003cli\u003eResistance and continuity\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Average to record signal fluctuations\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V safety rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e400 hours typical without back light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e9v\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT III Rating\u003c\/td\u003e\n\u003ctd\u003e600v\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e167 x 84 x 46 mm (6.57 x 3.31 x 1.82)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 °c to + 50 °c\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.9 % + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 °c to + 60 °c\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage AC Accuracy\u003c\/td\u003e\n\u003ctd\u003e1.0 % + 3 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage DC Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 114\/EFSP Electrical True RMS Multimeter\u003c\/li\u003e\n\u003cli\u003eHolster\u003c\/li\u003e\n\u003cli\u003eInstalled 9V Battery\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_114.PDF?1792\" target=\"_blank\" title=\"Fluke 114 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 114 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2018-02-21T12:05:55-07:00","created_at":"2018-02-21T12:10:46-07:00","vendor":"Fluke","type":"Multimeters","tags":[],"price":29728,"price_min":29728,"price_max":29728,"available":true,"price_varies":false,"compare_at_price":22700,"compare_at_price_min":22700,"compare_at_price_max":22700,"compare_at_price_varies":false,"variants":[{"id":11085613924395,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-114\/EFSP","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 114\/EFSP Electrical Multimeter, 600V","public_title":null,"options":["Default Title"],"price":29728,"weight":1814,"compare_at_price":22700,"inventory_management":"shopify","barcode":"095969324175","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_114-1.jpg?v=1569257007","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_114-2.jpg?v=1569257013"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_114-1.jpg?v=1569257007","options":["Title"],"media":[{"alt":null,"id":1443002122283,"position":1,"preview_image":{"aspect_ratio":0.6,"height":445,"width":267,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_114-1.jpg?v=1569257007"},"aspect_ratio":0.6,"height":445,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_114-1.jpg?v=1569257007","width":267},{"alt":null,"id":1443018244139,"position":2,"preview_image":{"aspect_ratio":1.0,"height":700,"width":700,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_114-2.jpg?v=1569257013"},"aspect_ratio":1.0,"height":700,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_114-2.jpg?v=1569257013","width":700}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan class=\"PrdPlainText\"\u003eCompact 600 V true-RMS meter for electrical troubleshooting. The Fluke 114 is the troubleshooting tool for “go\/no-go” testing and includes a feature to prevent false readings caused by ghost voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"PrdPlainText\"\u003eAlso check out the Fluke 115 Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117 Electrician’s Multimeter with Non-contact voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul class=\"PrdPlainText\"\u003e\n\u003cli\u003eAutoVolt: automatic ac\/dc voltage selection\u003c\/li\u003e\n\u003cli\u003eLarge white LED back light to work in poorly lit areas\u003c\/li\u003e\n\u003cli\u003eResistance and continuity\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Average to record signal fluctuations\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V safety rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e400 hours typical without back light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e9v\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAT III Rating\u003c\/td\u003e\n\u003ctd\u003e600v\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e167 x 84 x 46 mm (6.57 x 3.31 x 1.82)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 °c to + 50 °c\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.9 % + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 °c to + 60 °c\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage AC Accuracy\u003c\/td\u003e\n\u003ctd\u003e1.0 % + 3 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage DC Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.5% + 2 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 114\/EFSP Electrical True RMS Multimeter\u003c\/li\u003e\n\u003cli\u003eHolster\u003c\/li\u003e\n\u003cli\u003eInstalled 9V Battery\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_114.PDF?1792\" target=\"_blank\" title=\"Fluke 114 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 114 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e"}
Fluke 114/EFSP Electrical Multimeter, 600V

Fluke 114/EFSP Electrical Multimeter, 600V

$297.28 CAD

Compact 600 V true-RMS meter for electrical troubleshooting. The Fluke 114 is the troubleshooting tool for “go/no-go” testing and includes a feature to prevent false readings caused by ghost voltage. Also check out the Fluke 115 Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117 Electrician’s Multimeter ...


More Info
{"id":1037951598635,"title":"Fluke 115\/EFSP Field Service Technicians Multimeter, 600V","handle":"fluke-115-efsp-field-service-technicians-multimeter","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan class=\"PrdPlainText\"\u003eCompact true-RMS meter for field service technicians. The Fluke 115 is the solution for a wide variety of electrical and electronic testing applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"PrdPlainText\"\u003eAlso check out the Fluke 114 Electrical Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117 Electrician’s Multimeter with Non-contact voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eWith its simple operation, compact design and ease of use, the Fluke 115 True RMS digital multimeter provides the perfect answer for general purpose electrical and electronic test requirements. The Fluke 115 displays True RMS voltage and current readings with 600 count resolution, continuity and capacitance, making it perfect for quick verifications and field service use. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLarge white LED backlight to work in poorly lit areas\u003c\/li\u003e\n\u003cli\u003eResistance and continuity\u003c\/li\u003e\n\u003cli\u003eFrequency and capacitance\u003c\/li\u003e\n\u003cli\u003eMaximum Voltage ac\/dc 600V\u003c\/li\u003e\n\u003cli\u003e10A ac\/dc current measurement (20 A overload for 30-seconds max)\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Average to record signal fluctuations\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V safety rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Between any Terminal and Earth Ground\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003e6kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e6,000 counts, updates 4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar Graph\u003c\/td\u003e\n\u003ctd\u003e33 segments, updates 32 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e9 Volt Alkaline, NEDA 1604A\/ IEC 6LR61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e400 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"hidden\"\u003e\u003c\/h2\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 115\/EFSP Digital Multimeter with True RMS\u003c\/li\u003e\n\u003cli\u003eTL75 Test Leads\u003c\/li\u003e\n\u003cli\u003eHolster\u003c\/li\u003e\n\u003cli\u003eInstalled 9V Battery\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_115_Spec_Sheet.PDF?1793\" target=\"_blank\" title=\"Fluke 115 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 115 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2018-02-21T12:37:07-07:00","created_at":"2018-02-21T12:38:26-07:00","vendor":"Fluke","type":"Multimeters","tags":[],"price":36578,"price_min":36578,"price_max":36578,"available":true,"price_varies":false,"compare_at_price":26700,"compare_at_price_min":26700,"compare_at_price_max":26700,"compare_at_price_varies":false,"variants":[{"id":10704965500971,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-115\/EFSP","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 115\/EFSP Field Service Technicians Multimeter, 600V","public_title":null,"options":["Default Title"],"price":36578,"weight":2268,"compare_at_price":26700,"inventory_management":"shopify","barcode":"095969324182","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/71RIvVonyRL._SL1500.jpg?v=1519241909"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/71RIvVonyRL._SL1500.jpg?v=1519241909","options":["Title"],"media":[{"alt":null,"id":1416860762155,"position":1,"preview_image":{"aspect_ratio":0.801,"height":1500,"width":1201,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/71RIvVonyRL._SL1500.jpg?v=1519241909"},"aspect_ratio":0.801,"height":1500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/71RIvVonyRL._SL1500.jpg?v=1519241909","width":1201}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan class=\"PrdPlainText\"\u003eCompact true-RMS meter for field service technicians. The Fluke 115 is the solution for a wide variety of electrical and electronic testing applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"PrdPlainText\"\u003eAlso check out the Fluke 114 Electrical Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117 Electrician’s Multimeter with Non-contact voltage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eWith its simple operation, compact design and ease of use, the Fluke 115 True RMS digital multimeter provides the perfect answer for general purpose electrical and electronic test requirements. The Fluke 115 displays True RMS voltage and current readings with 600 count resolution, continuity and capacitance, making it perfect for quick verifications and field service use. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLarge white LED backlight to work in poorly lit areas\u003c\/li\u003e\n\u003cli\u003eResistance and continuity\u003c\/li\u003e\n\u003cli\u003eFrequency and capacitance\u003c\/li\u003e\n\u003cli\u003eMaximum Voltage ac\/dc 600V\u003c\/li\u003e\n\u003cli\u003e10A ac\/dc current measurement (20 A overload for 30-seconds max)\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Average to record signal fluctuations\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V safety rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Between any Terminal and Earth Ground\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003e6kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e6,000 counts, updates 4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar Graph\u003c\/td\u003e\n\u003ctd\u003e33 segments, updates 32 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e9 Volt Alkaline, NEDA 1604A\/ IEC 6LR61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e400 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 class=\"hidden\"\u003e\u003c\/h2\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 115\/EFSP Digital Multimeter with True RMS\u003c\/li\u003e\n\u003cli\u003eTL75 Test Leads\u003c\/li\u003e\n\u003cli\u003eHolster\u003c\/li\u003e\n\u003cli\u003eInstalled 9V Battery\u003c\/li\u003e\n\u003cli\u003eUser Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_115_Spec_Sheet.PDF?1793\" target=\"_blank\" title=\"Fluke 115 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 115 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e"}
Fluke 115/EFSP Field Service Technicians Multimeter, 600V

Fluke 115/EFSP Field Service Technicians Multimeter, 600V

$365.78 CAD

Compact true-RMS meter for field service technicians. The Fluke 115 is the solution for a wide variety of electrical and electronic testing applications. Also check out the Fluke 114 Electrical Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117 Electrician’s Multimeter with Non-contact voltage. Overview...


More Info
{"id":1038102528043,"title":"Fluke 116 HVAC Multimeter with Temperature and Microamps, 600V","handle":"fluke-116-hvac-multimeter-with-temperature-and-microamps","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eWith the ability to take temperature and microamp measurements, the Fluke 116 Digital Multimeter has everything you need to help you quickly troubleshoot problems with HVAC equipment and flame sensors. The Fluke 116 measures resistance, continuity, frequency and capacitance. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAlso check out the Fluke 114 Electrical Multimeter, the Fluke 115 Multimeter, and the Fluke 117, the Electrician’s Multimeter with Non-contact voltage.\u003c\/span\u003e \u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e \u003cspan\u003eWith the ability to take temperature and microamp measurements, the Fluke 116 digital multimeter delivers the capabilities professionals demand to quickly troubleshoot and repair HVAC equipment and flame sensors. A complete HVAC tool, the Fluke 116 measures resistance, continuity, frequency and capacitance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"PrdPlainText\"\u003e\n\u003cli\u003eBuilt-in thermometer for HVAC applications\u003c\/li\u003e\n\u003cli\u003eMicroamps to test flame sensors\u003c\/li\u003e\n\u003cli\u003eLow input impedance: helps prevent false readings due to ghost voltage\u003c\/li\u003e\n\u003cli\u003eLarge white LED backlight to work in poorly lit areas\u003c\/li\u003e\n\u003cli\u003eResistance, continuity, frequency and capacitance\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Average with elapsed time to record signal fluctuations\u003c\/li\u003e\n\u003cli\u003eCompact ergonomic design for one-handed operation\u003c\/li\u003e\n\u003cli\u003eCompatible with optional magnetic hanger (ToolPak™)\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V safety rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003e6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDigital: 6,000 counts, updates 4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar Graph\u003c\/td\u003e\n\u003ctd\u003e33 segments, updates 32 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to + 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to + 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e9 volt Alkaline, NEDA 1604A\/ IEC 6LR61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e400 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 116 HVAC Multimeter\u003c\/li\u003e\n\u003cli\u003eTL75 Test Leads\u003c\/li\u003e\n\u003cli\u003e80BK Integrated Temperature probe\u003c\/li\u003e\n\u003cli\u003eHolster\u003c\/li\u003e\n\u003cli\u003eInstalled 9 V battery\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_116_Data_Sheet.PDF?1794\" target=\"_blank\" title=\"Fluke 116 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 116 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2018-02-21T13:23:16-07:00","created_at":"2018-02-21T13:28:11-07:00","vendor":"Fluke","type":"Multimeters","tags":[],"price":37399,"price_min":37399,"price_max":37399,"available":true,"price_varies":false,"compare_at_price":26100,"compare_at_price_min":26100,"compare_at_price_max":26100,"compare_at_price_varies":false,"variants":[{"id":10705394761771,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-116","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 116 HVAC Multimeter with Temperature and Microamps, 600V","public_title":null,"options":["Default Title"],"price":37399,"weight":2268,"compare_at_price":26100,"inventory_management":"shopify","barcode":"095969324199","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/d51440c2ead77205fea08f248dc6b185.jpg?v=1519244894"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/d51440c2ead77205fea08f248dc6b185.jpg?v=1519244894","options":["Title"],"media":[{"alt":null,"id":1417046229035,"position":1,"preview_image":{"aspect_ratio":1.0,"height":2400,"width":2400,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/d51440c2ead77205fea08f248dc6b185.jpg?v=1519244894"},"aspect_ratio":1.0,"height":2400,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/d51440c2ead77205fea08f248dc6b185.jpg?v=1519244894","width":2400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eWith the ability to take temperature and microamp measurements, the Fluke 116 Digital Multimeter has everything you need to help you quickly troubleshoot problems with HVAC equipment and flame sensors. The Fluke 116 measures resistance, continuity, frequency and capacitance. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAlso check out the Fluke 114 Electrical Multimeter, the Fluke 115 Multimeter, and the Fluke 117, the Electrician’s Multimeter with Non-contact voltage.\u003c\/span\u003e \u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e \u003cspan\u003eWith the ability to take temperature and microamp measurements, the Fluke 116 digital multimeter delivers the capabilities professionals demand to quickly troubleshoot and repair HVAC equipment and flame sensors. A complete HVAC tool, the Fluke 116 measures resistance, continuity, frequency and capacitance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"PrdPlainText\"\u003e\n\u003cli\u003eBuilt-in thermometer for HVAC applications\u003c\/li\u003e\n\u003cli\u003eMicroamps to test flame sensors\u003c\/li\u003e\n\u003cli\u003eLow input impedance: helps prevent false readings due to ghost voltage\u003c\/li\u003e\n\u003cli\u003eLarge white LED backlight to work in poorly lit areas\u003c\/li\u003e\n\u003cli\u003eResistance, continuity, frequency and capacitance\u003c\/li\u003e\n\u003cli\u003eMin\/Max\/Average with elapsed time to record signal fluctuations\u003c\/li\u003e\n\u003cli\u003eCompact ergonomic design for one-handed operation\u003c\/li\u003e\n\u003cli\u003eCompatible with optional magnetic hanger (ToolPak™)\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V safety rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003e6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDigital: 6,000 counts, updates 4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar Graph\u003c\/td\u003e\n\u003ctd\u003e33 segments, updates 32 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to + 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to + 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e9 volt Alkaline, NEDA 1604A\/ IEC 6LR61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e400 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 116 HVAC Multimeter\u003c\/li\u003e\n\u003cli\u003eTL75 Test Leads\u003c\/li\u003e\n\u003cli\u003e80BK Integrated Temperature probe\u003c\/li\u003e\n\u003cli\u003eHolster\u003c\/li\u003e\n\u003cli\u003eInstalled 9 V battery\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_116_Data_Sheet.PDF?1794\" target=\"_blank\" title=\"Fluke 116 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 116 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e"}
Fluke 116 HVAC Multimeter with Temperature and Microamps, 600V

Fluke 116 HVAC Multimeter with Temperature and Microamps, 600V

$373.99 CAD

With the ability to take temperature and microamp measurements, the Fluke 116 Digital Multimeter has everything you need to help you quickly troubleshoot problems with HVAC equipment and flame sensors. The Fluke 116 measures resistance, continuity, frequency and capacitance.  Also check out the Fluke 114 Electrical Multimeter, the Fluke 115 Mul...


More Info
{"id":1253397561387,"title":"Fluke 116\/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter","handle":"fluke-116-323-hvac-multimeter-and-clamp-meter-combo-kit","description":"\u003cp\u003eThe Fluke 116 comes with the Fluke 80BK-A integrated DMM temperature probe; no need to carry a separate thermometer. The microamp function allows flame sensor measurement down to 0.1 microamps. The AutoV\/LoZ function prevents false readings caused by ghost voltage. The Fluke 116 also has a large white LED backlight for work in poorly lit areas. It measures resistance, continuity, frequency, and capacitance and provides Min\/Max\/Average readings with elapsed time to record signal fluctuations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eHaving the right tool for the job is essential. Having all the right tools when you need them is even better. The Fluke 116\/323 HVAC Combo Kit gives you the best in a versatile, rugged multimeter and a fast-acting, general purpose clamp meter.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 116 comes with the Fluke 80BK-A integrated DMM temperature probe; no need to carry a separate thermometer. The microamp function allows flame sensor measurement down to 0.1 microamps. The AutoV\/LoZ function prevents false readings caused by ghost voltage. The Fluke 116 also has a large white LED backlight for work in poorly lit areas. It measures resistance, continuity, frequency, and capacitance and provides Min\/Max\/Average readings with elapsed time to record signal fluctuations.\u003c\/p\u003e\n\u003cp\u003eFluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.\u003c\/p\u003e\n\u003cp\u003eTrue RMS measurements and optimized ergonomics make the Fluke 323 True RMS Clamp Meter the best general purpose clamp meter for commercial and residential electricians. The Fluke 323 model is ideally suited for current measurements up to 400 A in tight cable compartments.\u003c\/p\u003e\n\u003cp\u003eTogether, the Fluke 116 HVAC Multimeter and 323 True RMS Clamp Meter give electricians the right tools for the job.\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eFluke 116 HVAC Multimeter includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTL175 Hard Point Test Lead Set\u003c\/li\u003e\n\u003cli\u003eTPak ToolPak Magnetic Meter Hanging Strap\u003c\/li\u003e\n\u003cli\u003eFlexible Cuff Pipe Clamp Thermocouple\u003c\/li\u003e\n\u003cli\u003e80BK Integrated Temperature Probe\u003c\/li\u003e\n\u003cli\u003e80AK-A Thermocouple Adapter\u003c\/li\u003e\n\u003cli\u003eC115 Deluxe Soft Carrying Case with Shoulder Strap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFluke 323 True-rms Clamp Meter includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUser's manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_116_Data_Sheet.PDF?1794\" target=\"_blank\" title=\"Fluke 116 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 116 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_320_Series_Spec.PDF?1796\" target=\"_blank\" title=\"Fluke 323 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 323 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-05-11T13:57:12-06:00","created_at":"2018-05-11T14:00:27-06:00","vendor":"Fluke","type":"Clamp Meters","tags":[],"price":58479,"price_min":58479,"price_max":58479,"available":true,"price_varies":false,"compare_at_price":42000,"compare_at_price_min":42000,"compare_at_price_max":42000,"compare_at_price_varies":false,"variants":[{"id":12048101441579,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-116\/323-KIT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 116\/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter","public_title":null,"options":["Default Title"],"price":58479,"weight":3629,"compare_at_price":42000,"inventory_management":"shopify","barcode":"095969659208","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/116-323_1500x1500_9838bcea-8017-42dd-8f9b-1ca628d77023.jpg?v=1526068829"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/116-323_1500x1500_9838bcea-8017-42dd-8f9b-1ca628d77023.jpg?v=1526068829","options":["Title"],"media":[{"alt":null,"id":1646724972587,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/116-323_1500x1500_9838bcea-8017-42dd-8f9b-1ca628d77023.jpg?v=1526068829"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/116-323_1500x1500_9838bcea-8017-42dd-8f9b-1ca628d77023.jpg?v=1526068829","width":1500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe Fluke 116 comes with the Fluke 80BK-A integrated DMM temperature probe; no need to carry a separate thermometer. The microamp function allows flame sensor measurement down to 0.1 microamps. The AutoV\/LoZ function prevents false readings caused by ghost voltage. The Fluke 116 also has a large white LED backlight for work in poorly lit areas. It measures resistance, continuity, frequency, and capacitance and provides Min\/Max\/Average readings with elapsed time to record signal fluctuations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eHaving the right tool for the job is essential. Having all the right tools when you need them is even better. The Fluke 116\/323 HVAC Combo Kit gives you the best in a versatile, rugged multimeter and a fast-acting, general purpose clamp meter.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 116 comes with the Fluke 80BK-A integrated DMM temperature probe; no need to carry a separate thermometer. The microamp function allows flame sensor measurement down to 0.1 microamps. The AutoV\/LoZ function prevents false readings caused by ghost voltage. The Fluke 116 also has a large white LED backlight for work in poorly lit areas. It measures resistance, continuity, frequency, and capacitance and provides Min\/Max\/Average readings with elapsed time to record signal fluctuations.\u003c\/p\u003e\n\u003cp\u003eFluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.\u003c\/p\u003e\n\u003cp\u003eTrue RMS measurements and optimized ergonomics make the Fluke 323 True RMS Clamp Meter the best general purpose clamp meter for commercial and residential electricians. The Fluke 323 model is ideally suited for current measurements up to 400 A in tight cable compartments.\u003c\/p\u003e\n\u003cp\u003eTogether, the Fluke 116 HVAC Multimeter and 323 True RMS Clamp Meter give electricians the right tools for the job.\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eFluke 116 HVAC Multimeter includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTL175 Hard Point Test Lead Set\u003c\/li\u003e\n\u003cli\u003eTPak ToolPak Magnetic Meter Hanging Strap\u003c\/li\u003e\n\u003cli\u003eFlexible Cuff Pipe Clamp Thermocouple\u003c\/li\u003e\n\u003cli\u003e80BK Integrated Temperature Probe\u003c\/li\u003e\n\u003cli\u003e80AK-A Thermocouple Adapter\u003c\/li\u003e\n\u003cli\u003eC115 Deluxe Soft Carrying Case with Shoulder Strap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFluke 323 True-rms Clamp Meter includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUser's manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_116_Data_Sheet.PDF?1794\" target=\"_blank\" title=\"Fluke 116 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 116 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_320_Series_Spec.PDF?1796\" target=\"_blank\" title=\"Fluke 323 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 323 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter

Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter

$584.79 CAD

The Fluke 116 comes with the Fluke 80BK-A integrated DMM temperature probe; no need to carry a separate thermometer. The microamp function allows flame sensor measurement down to 0.1 microamps. The AutoV/LoZ function prevents false readings caused by ghost voltage. The Fluke 116 also has a large white LED backlight for work in poorly lit areas. ...


More Info
Fluke 116/62 MAX+ Technician’s Combo Kit

Infrared Thermometers

$489.59 CAD
{"id":1253138038827,"title":"Fluke 116\/62 MAX+ Technician’s Combo Kit","handle":"fluke-116-62-max-hvac-multimeter-and-ir-thermometer-kit","description":"\u003cp\u003e\u003cspan\u003eHaving the right tool for the job is essential. Having all the right tools when you need them is even better. The Fluke 116\/323 HVAC Combo Kit gives you the best in a versatile, rugged multimeter and a fast-acting, general purpose clamp meter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 116 comes with the Fluke 80BK-A integrated DMM temperature probe. The microamp function allows flame sensor measurement down to 0.1 microamps. The AutoV\/LoZ function prevents false readings caused by ghost voltage. The Fluke 116 also has a large white LED backlight for work in poorly lit areas. It measures resistance, continuity, frequency, and capacitance and provides Min\/Max\/Average readings with elapsed time to record signal fluctuations.\u003c\/p\u003e\n\u003cp\u003eFluke 116 multimeters are independently tested for safe use in CAT III 600V environments.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 62 MAX+ infrared thermometer is everything you'd want in your toolbox. Small in size, extremely accurate and yet easy to use. IP54 rated for dust and water resistance. Precise yet rugged enough to take a 3-meter drop.\u003c\/p\u003e\n\u003cp\u003eTogether, the Fluke 116 HVAC Multimeter and 62 MAX+ Infrared Thermometer give HVAC technicians the right tools for the job.\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ch4\u003eFluke 116 Multimeter\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6,000 counts, updates 4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar graph\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e33 segments, updates 32 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e9 volt Alkaline, NEDA 1604A\/ IEC 6LR61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC millivolts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC volts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.00 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAuto volts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e4.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC millivolts\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eTrue RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC volts\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eTrue RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eBeeper on \u0026lt; 20 Ω, off \u0026gt; 250 Ω; detects opens or shorts of 500 μs or longer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eOhms\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω \/ 0.1 Ω\u003cbr\u003e6.000 kΩ \/ 0.001 kΩ\u003cbr\u003e60.00 kΩ \/ 0.01 kΩ\u003cbr\u003e600.0 kΩ \/ 0.1 kΩ\u003cbr\u003e6.000 MΩ \/ 0.001 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e40.00 MΩ \/ 0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDiode Test\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2.000 V \/ 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 nF \/ 1 nF\u003cbr\u003e10.00 μF \/ 0.01 μF\u003cbr\u003e100.0 μF \/ 0.1 μF\u003cbr\u003e9999 μF \/ 1 μF\u003cbr\u003e100 μF to 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e5% + 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eLoZ capacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1 nF to 500 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e10% + 2 typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eTemperature\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e(Type-K thermocouple)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to 400°C \/ 0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1% + 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°F to 752°F \/ 0.2°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1% + 18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC μamps true-rms (45 Hz to 500 Hz)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 μA \/ 0.1 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC μamps\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 μA \/ 0.1 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHz (V or A input)\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e99.99 Hz \/ 0.01 Hz\u003cbr\u003e999.99 Hz \/ 0.1 Hz\u003cbr\u003e9.999 Hz \/ 0.001 Hz\u003cbr\u003e50.00 Hz \/ 0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"3\"\u003e1. All AC voltage ranges except Auto-V\/LoZ are specified from 1% to 100% of range. Auto-V\/LoZ is specified from 0.0 V.\u003cbr\u003e2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.\u003cbr\u003e• Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.\u003cbr\u003e• Temperature Range\/Resolution: -40°F to 752°F \/ 0.2°F.\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eFluke 62 MAX+ Infrared Thermometer\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-30°C to 650°C (-22°F to 1202°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±1.0°C or ±1.0% of reading, whichever is greater\u003cbr\u003e-10°C to 0°C: ±2.0\u003cbr\u003e-30°C to -10°C: ±3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResponse time (95%)\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e\u0026lt; 300 ms (95% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral response\u003c\/td\u003e\n\u003ctd\u003e8 to 14 microns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissivity\u003c\/td\u003e\n\u003ctd\u003e0.10 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12:1 (calculated at 90% energy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C (0.2°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability of readings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.5% of reading or \u0026lt;±0.5°C (1°F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAA battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 hours with laser and backlight on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePhysical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e255 g (8.99 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 60°C (-4°F to 140°F), (without battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10% to 90% RH non-condensing at 30°C (86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12,000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 54 per IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration and shock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61326-1:2006 EN 61326-2:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eStandards and agency approval\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eCompliance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 61010-1: 2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser safety\u003c\/td\u003e\n\u003ctd\u003eFDA and EN 60825-1 Class II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 116 HVAC\/R Multimeter with Temperature and Microamps.\u003c\/li\u003e\n\u003cli\u003eTL75 Hard Point Test Lead Set.\u003c\/li\u003e\n\u003cli\u003eTPak ToolPak Magnetic Meter Hanging Strap.\u003c\/li\u003e\n\u003cli\u003eFlexible Cuff Pipe Clamp Thermocouple.\u003c\/li\u003e\n\u003cli\u003e80BK Integrated Temperature Probe.\u003c\/li\u003e\n\u003cli\u003e80AK-A Thermocouple Adapter.\u003c\/li\u003e\n\u003cli\u003eC115 Deluxe Soft Carrying Case with Shoulder Strap.\u003c\/li\u003e\n\u003cli\u003eFluke 62 MAX+ Infrared Thermometer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_116_Data_Sheet.PDF?1796\" target=\"_blank\" title=\"Fluke 116 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 116 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_62_MAX_and_62_MAX_data_sheet.pdf?1798\" target=\"_blank\" title=\"Fluke 62Max+ Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 62Max+ Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-05-11T09:18:57-06:00","created_at":"2018-05-11T09:31:15-06:00","vendor":"Fluke","type":"Infrared Thermometers","tags":[],"price":48959,"price_min":48959,"price_max":48959,"available":true,"price_varies":false,"compare_at_price":37300,"compare_at_price_min":37300,"compare_at_price_max":37300,"compare_at_price_varies":false,"variants":[{"id":12045331562539,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-116\/62MAX+","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 116\/62 MAX+ Technician’s Combo Kit","public_title":null,"options":["Default Title"],"price":48959,"weight":3629,"compare_at_price":37300,"inventory_management":"shopify","barcode":"095969659192","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_116-62-max-plus.jpg?v=1569260521","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_116-62-max-plus-2.jpg?v=1569260576"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_116-62-max-plus.jpg?v=1569260521","options":["Title"],"media":[{"alt":null,"id":1454374879275,"position":1,"preview_image":{"aspect_ratio":1.493,"height":402,"width":600,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_116-62-max-plus.jpg?v=1569260521"},"aspect_ratio":1.493,"height":402,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_116-62-max-plus.jpg?v=1569260521","width":600},{"alt":null,"id":1454493237291,"position":2,"preview_image":{"aspect_ratio":1.0,"height":900,"width":900,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_116-62-max-plus-2.jpg?v=1569260576"},"aspect_ratio":1.0,"height":900,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_116-62-max-plus-2.jpg?v=1569260576","width":900}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eHaving the right tool for the job is essential. Having all the right tools when you need them is even better. The Fluke 116\/323 HVAC Combo Kit gives you the best in a versatile, rugged multimeter and a fast-acting, general purpose clamp meter.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eThe Fluke 116 comes with the Fluke 80BK-A integrated DMM temperature probe. The microamp function allows flame sensor measurement down to 0.1 microamps. The AutoV\/LoZ function prevents false readings caused by ghost voltage. The Fluke 116 also has a large white LED backlight for work in poorly lit areas. It measures resistance, continuity, frequency, and capacitance and provides Min\/Max\/Average readings with elapsed time to record signal fluctuations.\u003c\/p\u003e\n\u003cp\u003eFluke 116 multimeters are independently tested for safe use in CAT III 600V environments.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 62 MAX+ infrared thermometer is everything you'd want in your toolbox. Small in size, extremely accurate and yet easy to use. IP54 rated for dust and water resistance. Precise yet rugged enough to take a 3-meter drop.\u003c\/p\u003e\n\u003cp\u003eTogether, the Fluke 116 HVAC Multimeter and 62 MAX+ Infrared Thermometer give HVAC technicians the right tools for the job.\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ch4\u003eFluke 116 Multimeter\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6,000 counts, updates 4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar graph\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e33 segments, updates 32 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e9 volt Alkaline, NEDA 1604A\/ IEC 6LR61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC millivolts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC volts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.00 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAuto volts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e4.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC millivolts\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eTrue RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC volts\u003csup\u003e1\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eTrue RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eBeeper on \u0026lt; 20 Ω, off \u0026gt; 250 Ω; detects opens or shorts of 500 μs or longer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eOhms\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω \/ 0.1 Ω\u003cbr\u003e6.000 kΩ \/ 0.001 kΩ\u003cbr\u003e60.00 kΩ \/ 0.01 kΩ\u003cbr\u003e600.0 kΩ \/ 0.1 kΩ\u003cbr\u003e6.000 MΩ \/ 0.001 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e40.00 MΩ \/ 0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDiode Test\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2.000 V \/ 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 nF \/ 1 nF\u003cbr\u003e10.00 μF \/ 0.01 μF\u003cbr\u003e100.0 μF \/ 0.1 μF\u003cbr\u003e9999 μF \/ 1 μF\u003cbr\u003e100 μF to 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e5% + 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eLoZ capacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1 nF to 500 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e10% + 2 typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eTemperature\u003csup\u003e2\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003e(Type-K thermocouple)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to 400°C \/ 0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1% + 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°F to 752°F \/ 0.2°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1% + 18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC μamps true-rms (45 Hz to 500 Hz)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 μA \/ 0.1 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC μamps\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 μA \/ 0.1 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHz (V or A input)\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/Resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e99.99 Hz \/ 0.01 Hz\u003cbr\u003e999.99 Hz \/ 0.1 Hz\u003cbr\u003e9.999 Hz \/ 0.001 Hz\u003cbr\u003e50.00 Hz \/ 0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"3\"\u003e1. All AC voltage ranges except Auto-V\/LoZ are specified from 1% to 100% of range. Auto-V\/LoZ is specified from 0.0 V.\u003cbr\u003e2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.\u003cbr\u003e• Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.\u003cbr\u003e• Temperature Range\/Resolution: -40°F to 752°F \/ 0.2°F.\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eFluke 62 MAX+ Infrared Thermometer\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-30°C to 650°C (-22°F to 1202°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±1.0°C or ±1.0% of reading, whichever is greater\u003cbr\u003e-10°C to 0°C: ±2.0\u003cbr\u003e-30°C to -10°C: ±3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eResponse time (95%)\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e\u0026lt; 300 ms (95% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral response\u003c\/td\u003e\n\u003ctd\u003e8 to 14 microns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissivity\u003c\/td\u003e\n\u003ctd\u003e0.10 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12:1 (calculated at 90% energy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C (0.2°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability of readings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.5% of reading or \u0026lt;±0.5°C (1°F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAA battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 hours with laser and backlight on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePhysical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e255 g (8.99 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 60°C (-4°F to 140°F), (without battery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10% to 90% RH non-condensing at 30°C (86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage altitude\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e12,000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 54 per IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop test\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration and shock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEN 61326-1:2006 EN 61326-2:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eStandards and agency approval\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eCompliance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 61010-1: 2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser safety\u003c\/td\u003e\n\u003ctd\u003eFDA and EN 60825-1 Class II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 116 HVAC\/R Multimeter with Temperature and Microamps.\u003c\/li\u003e\n\u003cli\u003eTL75 Hard Point Test Lead Set.\u003c\/li\u003e\n\u003cli\u003eTPak ToolPak Magnetic Meter Hanging Strap.\u003c\/li\u003e\n\u003cli\u003eFlexible Cuff Pipe Clamp Thermocouple.\u003c\/li\u003e\n\u003cli\u003e80BK Integrated Temperature Probe.\u003c\/li\u003e\n\u003cli\u003e80AK-A Thermocouple Adapter.\u003c\/li\u003e\n\u003cli\u003eC115 Deluxe Soft Carrying Case with Shoulder Strap.\u003c\/li\u003e\n\u003cli\u003eFluke 62 MAX+ Infrared Thermometer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_116_Data_Sheet.PDF?1796\" target=\"_blank\" title=\"Fluke 116 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 116 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_62_MAX_and_62_MAX_data_sheet.pdf?1798\" target=\"_blank\" title=\"Fluke 62Max+ Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 62Max+ Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 116/62 MAX+ Technician’s Combo Kit

Fluke 116/62 MAX+ Technician’s Combo Kit

$489.59 CAD

Having the right tool for the job is essential. Having all the right tools when you need them is even better. The Fluke 116/323 HVAC Combo Kit gives you the best in a versatile, rugged multimeter and a fast-acting, general purpose clamp meter. Overview The Fluke 116 comes with the Fluke 80BK-A integrated DMM temperature probe. The microamp func...


More Info
{"id":1037902053419,"title":"Fluke 117 Electrician's Ideal Multimeter with Non-Contact Voltage","handle":"fluke-117-efsp-electricians-multimeter-with-non-contact-voltage","description":"\u003cp\u003e\u003cspan\u003eDesigned by electricians and engineered by Fluke, the Fluke 117 is a compact True-RMS meter for demanding applications like commercial buildings, hospitals, and schools. With its integrated non-contact voltage detection, Auto Volts and LoZ functions that help prevent false readings caused by ghost voltage, the Fluke 117 is a great choice for electricians. In fact, users around the world have said their 117 is an investment in accuracy. The Fluke 117 provides Min\/Max\/Average readings and measures frequency and capacitance. Plus, its easy-to-use interface can save you time and enable you to move from job to job more quickly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAccurate, easy-to-use multimeter with integrated VoltAlert™ technology for non-contact voltage detection\u003c\/li\u003e\n\u003cli\u003eFeatures AutoVolt automatic AC\/DC voltage selection\u003c\/li\u003e\n\u003cli\u003eProvides low input impedance to help prevent false readings due to ghost voltage\u003c\/li\u003e\n\u003cli\u003ePresents a large white LED backlight for working in poorly lit areas\u003c\/li\u003e\n\u003cli\u003eFeatures True RMS capabilities for accurate measurements on non-linear loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse for A input\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e11 A, 1000 V FAST Fuse (Fluke PN 803293)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDigital: 6,000 counts, updates 4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar graph\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e33 segments, updates 32 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e9 volt Alkaline, NEDA 1604A \/ IEC 6LR61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC millivolts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC volts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.00 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAuto volts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e4.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC millivolts¹ True RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC volts¹ True RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eBeeper on \u0026lt; 20 Ω, off \u0026gt; 250 Ω detects opens or shorts of\u003cbr\u003e500 μs or longer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eOhms\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω \/ 0.1 Ω\u003cbr\u003e6.000 kΩ \/ 0.001 kΩ\u003cbr\u003e60.00 kΩ \/ 0.01 kΩ\u003cbr\u003e600.0 kΩ \/ 0.1 kΩ\u003cbr\u003e6.000 MΩ \/ 0.001 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/resolution\u003c\/td\u003e\n\u003ctd\u003e40.00 MΩ \/ 0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2.00 V \/ 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 nF \/ 1 nF\u003cbr\u003e10.00 μF \/ 0.01 μF\u003cbr\u003e100.0 μF \/ 0.1 μF\u003cbr\u003e9999 μF \/ 1 μF\u003cbr\u003e100 μF to 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/resolution\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e5% + 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eLo-Z capacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1 nF to 500 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e10% + 2 typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC amps True RMS (45 Hz to 500 Hz)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 A \/ 0.001 A\u003cbr\u003e10.00 A \/ 0.01 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003cbr\u003e20 A continuous overload for 30 seconds max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC amps\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6.000 A \/ 0.001 A   10.00 A \/ 0.01 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3\u003cbr\u003e20 A continuous overload for 30 seconds max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHz (V or A input)²\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e99.99 Hz \/ 0.01 Hz\u003cbr\u003e999.9 Hz \/ 0.1 Hz\u003cbr\u003e9.999 kHz \/ 0.001 Hz\u003cbr\u003e50.00 kHz \/ 0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"3\"\u003e1. All AC voltage ranges except Auto-V\/LoZ are specified from 1% to 100% of range. Auto-V\/LoZ is specified from 0.0 V.\u003cbr\u003e2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.\u003cbr\u003e2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.\u003cbr\u003e2. Temperature Range\/Resolution: -40°F to 752°F \/ 0.2°F.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4 mm silicone test lead set\u003c\/li\u003e\n\u003cli\u003eHolster\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_117_Spec_Sheet.pdf?1799\" target=\"_blank\" title=\"Fluke 117 Multimeter\" rel=\"noopener noreferrer\"\u003eFluke 117 Multimeter\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-02-21T12:11:58-07:00","created_at":"2018-02-21T12:15:00-07:00","vendor":"Fluke","type":"Multimeters","tags":[],"price":39439,"price_min":39439,"price_max":39439,"available":true,"price_varies":false,"compare_at_price":28700,"compare_at_price_min":28700,"compare_at_price_max":28700,"compare_at_price_varies":false,"variants":[{"id":10704666984491,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-117","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 117 Electrician's Ideal Multimeter with Non-Contact Voltage","public_title":null,"options":["Default Title"],"price":39439,"weight":2268,"compare_at_price":28700,"inventory_management":"shopify","barcode":"095969324205","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/71s1n5qCtjL._SL1500.jpg?v=1519240502"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/71s1n5qCtjL._SL1500.jpg?v=1519240502","options":["Title"],"media":[{"alt":null,"id":1416783331371,"position":1,"preview_image":{"aspect_ratio":0.8,"height":1500,"width":1200,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/71s1n5qCtjL._SL1500.jpg?v=1519240502"},"aspect_ratio":0.8,"height":1500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/71s1n5qCtjL._SL1500.jpg?v=1519240502","width":1200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eDesigned by electricians and engineered by Fluke, the Fluke 117 is a compact True-RMS meter for demanding applications like commercial buildings, hospitals, and schools. With its integrated non-contact voltage detection, Auto Volts and LoZ functions that help prevent false readings caused by ghost voltage, the Fluke 117 is a great choice for electricians. In fact, users around the world have said their 117 is an investment in accuracy. The Fluke 117 provides Min\/Max\/Average readings and measures frequency and capacitance. Plus, its easy-to-use interface can save you time and enable you to move from job to job more quickly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAccurate, easy-to-use multimeter with integrated VoltAlert™ technology for non-contact voltage detection\u003c\/li\u003e\n\u003cli\u003eFeatures AutoVolt automatic AC\/DC voltage selection\u003c\/li\u003e\n\u003cli\u003eProvides low input impedance to help prevent false readings due to ghost voltage\u003c\/li\u003e\n\u003cli\u003ePresents a large white LED backlight for working in poorly lit areas\u003c\/li\u003e\n\u003cli\u003eFeatures True RMS capabilities for accurate measurements on non-linear loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage between any terminal and earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse for A input\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e11 A, 1000 V FAST Fuse (Fluke PN 803293)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDigital: 6,000 counts, updates 4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBar graph\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e33 segments, updates 32 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e9 volt Alkaline, NEDA 1604A \/ IEC 6LR61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 hours typical, without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC millivolts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC volts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.00 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±([% of reading] + [counts]): 0.5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAuto volts\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e2.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e4.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC millivolts¹ True RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 mV \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC volts¹ True RMS\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 V \/ 0.001 V\u003cbr\u003e60.00 V \/ 0.01 V\u003cbr\u003e600.0 V \/ 0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3 (DC, 45 Hz to 500 Hz)\u003cbr\u003e2.0% + 3 (500 Hz to 1 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600 Ω \/ 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eBeeper on \u0026lt; 20 Ω, off \u0026gt; 250 Ω detects opens or shorts of\u003cbr\u003e500 μs or longer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eOhms\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 Ω \/ 0.1 Ω\u003cbr\u003e6.000 kΩ \/ 0.001 kΩ\u003cbr\u003e60.00 kΩ \/ 0.01 kΩ\u003cbr\u003e600.0 kΩ \/ 0.1 kΩ\u003cbr\u003e6.000 MΩ \/ 0.001 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/resolution\u003c\/td\u003e\n\u003ctd\u003e40.00 MΩ \/ 0.01 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e5% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDiode test\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2.00 V \/ 0.001 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 nF \/ 1 nF\u003cbr\u003e10.00 μF \/ 0.01 μF\u003cbr\u003e100.0 μF \/ 0.1 μF\u003cbr\u003e9999 μF \/ 1 μF\u003cbr\u003e100 μF to 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.9% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\/resolution\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1000 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e5% + 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eLo-Z capacitance\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1 nF to 500 μF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e10% + 2 typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAC amps True RMS (45 Hz to 500 Hz)\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e6.000 A \/ 0.001 A\u003cbr\u003e10.00 A \/ 0.01 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.5% + 3\u003cbr\u003e20 A continuous overload for 30 seconds max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDC amps\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e6.000 A \/ 0.001 A   10.00 A \/ 0.01 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e1.0% + 3\u003cbr\u003e20 A continuous overload for 30 seconds max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHz (V or A input)²\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\/resolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e99.99 Hz \/ 0.01 Hz\u003cbr\u003e999.9 Hz \/ 0.1 Hz\u003cbr\u003e9.999 kHz \/ 0.001 Hz\u003cbr\u003e50.00 kHz \/ 0.01 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% + 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"3\"\u003e1. All AC voltage ranges except Auto-V\/LoZ are specified from 1% to 100% of range. Auto-V\/LoZ is specified from 0.0 V.\u003cbr\u003e2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.\u003cbr\u003e2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.\u003cbr\u003e2. Temperature Range\/Resolution: -40°F to 752°F \/ 0.2°F.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMechanical and General Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4 mm silicone test lead set\u003c\/li\u003e\n\u003cli\u003eHolster\u003c\/li\u003e\n\u003cli\u003eUser manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_117_Spec_Sheet.pdf?1799\" target=\"_blank\" title=\"Fluke 117 Multimeter\" rel=\"noopener noreferrer\"\u003eFluke 117 Multimeter\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 117 Electrician's Ideal Multimeter with Non-Contact Voltage

Fluke 117 Electrician's Ideal Multimeter with Non-Contact Voltage

$394.39 CAD

Designed by electricians and engineered by Fluke, the Fluke 117 is a compact True-RMS meter for demanding applications like commercial buildings, hospitals, and schools. With its integrated non-contact voltage detection, Auto Volts and LoZ functions that help prevent false readings caused by ghost voltage, the Fluke 117 is a great choice for ele...


More Info
{"id":1052221669419,"title":"Fluke 117\/323 Electricians Multimeter Combo Kit","handle":"fluke-117-323-electricians-multimeter-combo-kit-1","description":"\u003cp\u003eHaving the right tool for the job is essential. Having all the right tools when you need them is even better. The Fluke 117\/323 Electricians Multimeter Combo Kit gives you the best in a versatile, rugged multimeter and a fast-acting, general purpose clamp meter.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 117 provides non-contact voltage detection, an AutoV\/LoZ function, Min\/Max\/Average readings, plus frequency and capacitance measurements. It's easy to use and saves you time.\u003c\/p\u003e\n\u003cp\u003eTrue RMS measurements and optimized ergonomics make the Fluke 323 True RMS Clamp Meter the best general purpose clamp meter for commercial and residential electricians. The Fluke 323 model is ideally suited for current measurements up to 400 A in tight cable compartments.\u003c\/p\u003e\n\u003cp\u003eTogether, the Fluke 117 Electricians Multimeter and 323 True-rms Clamp Meter give electricians the right tools for the job.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 117 Electrician's Multimeter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFast go\/no-go testing with VoltAlert™ non-contact voltage detection\u003c\/li\u003e\n\u003cli\u003eAutoVolt automatic AC\/DC voltage selection\u003c\/li\u003e\n\u003cli\u003eLow input impedance helps prevent false readings due to ghost voltage\u003c\/li\u003e\n\u003cli\u003eWork in poorly lit areas with the Large white LED backlit display\u003c\/li\u003e\n\u003cli\u003eTrue RMS voltage and current for accurate measurements on non-linear loads\u003c\/li\u003e\n\u003cli\u003eMeasures 10 A directly (20 A overload for 30-seconds) without a current clamp\u003c\/li\u003e\n\u003cli\u003eResistance, continuity, frequency and capacitance\u003c\/li\u003e\n\u003cli\u003eRecord signal fluctuations using Min\/Max\/Average and elapsed time stamps\u003c\/li\u003e\n\u003cli\u003eEasy to use with one hand\u003c\/li\u003e\n\u003cli\u003eHands free operation with optional magnetic hanger (ToolPak™)\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V safety rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 323 True-rms Clamp Meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e400 A AC current measurement\u003c\/li\u003e\n\u003cli\u003e600 VAC and DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue RMS AC voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eResistance measurement up to 40 kΩ with continuity detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Multimeter\u003c\/li\u003e\n\u003cli\u003eClamp Meter\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003cli\u003eTPAK ToolPak Magnetic Meter Hanger\u003c\/li\u003e\n\u003cli\u003eC115 Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_117_Spec_Sheet.pdf?1799\" target=\"_blank\" title=\"Fluke 117 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 117 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_320_Series_Spec.PDF?1798\" target=\"_blank\" title=\"Fluke 323 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 323 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-02-26T15:33:11-07:00","created_at":"2018-02-26T15:41:09-07:00","vendor":"Fluke","type":"Clamp Meters","tags":[],"price":61199,"price_min":61199,"price_max":61199,"available":true,"price_varies":false,"compare_at_price":47300,"compare_at_price_min":47300,"compare_at_price_max":47300,"compare_at_price_varies":false,"variants":[{"id":10832626188331,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-117\/323-KIT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 117\/323 Electricians Multimeter Combo Kit","public_title":null,"options":["Default Title"],"price":61199,"weight":2268,"compare_at_price":47300,"inventory_management":"shopify","barcode":"095969659222","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/71DDJsVn7EL._SL1500_-1.jpg?v=1519684871","\/\/kingswayinstruments.com\/cdn\/shop\/products\/61O5jixVf7L._SL1500.jpg?v=1519684871","\/\/kingswayinstruments.com\/cdn\/shop\/products\/s-l1000.jpg?v=1519684872","\/\/kingswayinstruments.com\/cdn\/shop\/products\/715lQkVp2tL._SL1500.jpg?v=1519684873"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/71DDJsVn7EL._SL1500_-1.jpg?v=1519684871","options":["Title"],"media":[{"alt":null,"id":1439771721771,"position":1,"preview_image":{"aspect_ratio":1.5,"height":1000,"width":1500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/71DDJsVn7EL._SL1500_-1.jpg?v=1519684871"},"aspect_ratio":1.5,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/71DDJsVn7EL._SL1500_-1.jpg?v=1519684871","width":1500},{"alt":null,"id":1439771754539,"position":2,"preview_image":{"aspect_ratio":0.578,"height":1500,"width":867,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/61O5jixVf7L._SL1500.jpg?v=1519684871"},"aspect_ratio":0.578,"height":1500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/61O5jixVf7L._SL1500.jpg?v=1519684871","width":867},{"alt":null,"id":1439771820075,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/s-l1000.jpg?v=1519684872"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/s-l1000.jpg?v=1519684872","width":1000},{"alt":null,"id":1439771852843,"position":4,"preview_image":{"aspect_ratio":0.714,"height":1500,"width":1071,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/715lQkVp2tL._SL1500.jpg?v=1519684873"},"aspect_ratio":0.714,"height":1500,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/715lQkVp2tL._SL1500.jpg?v=1519684873","width":1071}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eHaving the right tool for the job is essential. Having all the right tools when you need them is even better. The Fluke 117\/323 Electricians Multimeter Combo Kit gives you the best in a versatile, rugged multimeter and a fast-acting, general purpose clamp meter.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 117 provides non-contact voltage detection, an AutoV\/LoZ function, Min\/Max\/Average readings, plus frequency and capacitance measurements. It's easy to use and saves you time.\u003c\/p\u003e\n\u003cp\u003eTrue RMS measurements and optimized ergonomics make the Fluke 323 True RMS Clamp Meter the best general purpose clamp meter for commercial and residential electricians. The Fluke 323 model is ideally suited for current measurements up to 400 A in tight cable compartments.\u003c\/p\u003e\n\u003cp\u003eTogether, the Fluke 117 Electricians Multimeter and 323 True-rms Clamp Meter give electricians the right tools for the job.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 117 Electrician's Multimeter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFast go\/no-go testing with VoltAlert™ non-contact voltage detection\u003c\/li\u003e\n\u003cli\u003eAutoVolt automatic AC\/DC voltage selection\u003c\/li\u003e\n\u003cli\u003eLow input impedance helps prevent false readings due to ghost voltage\u003c\/li\u003e\n\u003cli\u003eWork in poorly lit areas with the Large white LED backlit display\u003c\/li\u003e\n\u003cli\u003eTrue RMS voltage and current for accurate measurements on non-linear loads\u003c\/li\u003e\n\u003cli\u003eMeasures 10 A directly (20 A overload for 30-seconds) without a current clamp\u003c\/li\u003e\n\u003cli\u003eResistance, continuity, frequency and capacitance\u003c\/li\u003e\n\u003cli\u003eRecord signal fluctuations using Min\/Max\/Average and elapsed time stamps\u003c\/li\u003e\n\u003cli\u003eEasy to use with one hand\u003c\/li\u003e\n\u003cli\u003eHands free operation with optional magnetic hanger (ToolPak™)\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V safety rated\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 323 True-rms Clamp Meter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e400 A AC current measurement\u003c\/li\u003e\n\u003cli\u003e600 VAC and DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue RMS AC voltage and current for accurate measurements on non-linear signals\u003c\/li\u003e\n\u003cli\u003eResistance measurement up to 40 kΩ with continuity detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Multimeter\u003c\/li\u003e\n\u003cli\u003eClamp Meter\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003cli\u003eTPAK ToolPak Magnetic Meter Hanger\u003c\/li\u003e\n\u003cli\u003eC115 Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_117_Spec_Sheet.pdf?1799\" target=\"_blank\" title=\"Fluke 117 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 117 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_320_Series_Spec.PDF?1798\" target=\"_blank\" title=\"Fluke 323 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 323 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 117/323 Electricians Multimeter Combo Kit

Fluke 117/323 Electricians Multimeter Combo Kit

$611.99 CAD

Having the right tool for the job is essential. Having all the right tools when you need them is even better. The Fluke 117/323 Electricians Multimeter Combo Kit gives you the best in a versatile, rugged multimeter and a fast-acting, general purpose clamp meter. The Fluke 117 provides non-contact voltage detection, an AutoV/LoZ function, Min/Max...


More Info
{"id":1253384290347,"title":"Fluke 123B Industrial ScopeMeter® Hand-Held Oscilloscope, 2 Channel, 20MHz","handle":"fluke-123-industrial-scopemeter","description":"\u003cp\u003e\u003cspan\u003eThe compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input digital oscilloscope and multimeter\u003c\/li\u003e\n\u003cli\u003e20 MHz oscilloscope bandwidth\u003c\/li\u003e\n\u003cli\u003eTwo 5,000-count true-rms digital multimeters\u003c\/li\u003e\n\u003cli\u003eConnect-and-View™ trigger simplicity for hands-off operation; IntellaSet™ technology automatically and intelligently adjusts numerical readout\u003c\/li\u003e\n\u003cli\u003eDual-input waveform and meter reading recorder for trending data over extended periods\u003c\/li\u003e\n\u003cli\u003eRecorder Event Detect captures elusive intermittent signals\u003c\/li\u003e\n\u003cli\u003eWiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app*\u003c\/li\u003e\n\u003cli\u003eFlukeView® ScopeMeter® Software for Windows® (FLU-123B\/NA\/S)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eTrigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen update\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFree run, on trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA, B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eSensitivity A and B\u003c\/td\u003e\n\u003ctd\u003e@ DC to 5 MHz\u003c\/td\u003e\n\u003ctd\u003e0.5 divisions or 5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" rowspan=\"2\"\u003e@ 40 MHz\u003c\/td\u003e\n\u003ctd\u003e123B: 4 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 1.5 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" rowspan=\"2\"\u003e@ 60 MHz\u003c\/td\u003e\n\u003ctd\u003e123B: N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 4 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePositive, negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAdvanced scope functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eDisplay modes\u003c\/td\u003e\n\u003ctd\u003eNormal\u003c\/td\u003e\n\u003ctd\u003eCaptures up to 25 ns glitches and displays analog-like persistence waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eSmooth\u003c\/td\u003e\n\u003ctd\u003eSuppresses noise from a waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eGlitch off\u003c\/td\u003e\n\u003ctd\u003eDoes not capture glitches between samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEnvelope\u003c\/td\u003e\n\u003ctd\u003eRecords and displays the minimum and maximum of waveforms over time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto set (Connect-and-View™)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eContinuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eInput A and input B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC voltage (VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.5% +5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection (CMRR)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;100 dB @ dc, \u0026gt;60 dB @ 50, 60, or 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eTrue-rms voltages (V ac and V ac+dc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy for 5% to 100% of range (DC coupled)\u003c\/td\u003e\n\u003ctd\u003eDC to 60 Hz (V ac+dc)\u003c\/td\u003e\n\u003ctd\u003e±(1% +10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e1 Hz to 60 Hz (V ac)\u003c\/td\u003e\n\u003ctd\u003e±(1% +10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy for 5% to 100% of range (AC or dc coupled)\u003c\/td\u003e\n\u003ctd\u003e60 Hz to 20 kHz\u003c\/td\u003e\n\u003ctd\u003e±(2.5% +15 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC rejection (only VAC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;50 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCommon mode rejection (CMRR)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;100 dB @ dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e\u0026gt;60 dB @ 50, 60, or 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts, reading is independent of any signal crest factor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePeak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMax peak, Min peak, or pk-to-pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 2200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eAccuracy Max peak or Min peak\u003c\/td\u003e\n\u003ctd\u003e5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy Peak-to-Peak\u003c\/td\u003e\n\u003ctd\u003e10% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eRecorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMeter readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Speed\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMaximum 2 measurement\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size (min, max, average)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 M readings for 1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eWaveform record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum sample rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 K sample\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize Internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 M samples Recorded Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 minutes at 500 μs\/div\u003cbr\u003e11 hours at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5 G samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e11 hours at 500 μs\/div\u003cbr\u003e14 days at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003ePower Quality (125B only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWatt, VA, var, PF, DPF, Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eWatt, VA, var ranges (auto)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e250 W to 250 MW, 625 MW, 1.56 GW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: total (% r)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 6 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: fundamental (% f)\u003c\/td\u003e\n\u003ctd\u003e±(4% + 4 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDPF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00, ±0.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10.0 Hz to 15.0 kHz\u003cbr\u003e40.0 Hz to 70.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Harmonics\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDC to 51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings \/ Cursor readings \u003cbr\u003e(fundamental 40 Hz to 70 Hz)\u003c\/td\u003e\n\u003ctd\u003eVrms \/ Arms \/Watt\u003c\/td\u003e\n\u003ctd\u003eEach harmonic from fundamental maybe selected for individual readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eIncludes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOscilloscope\u003c\/li\u003e\n\u003cli\u003eAccessory List\u003c\/li\u003e\n\u003cli\u003eCD\u003c\/li\u003e\n\u003cli\u003eSafety Manual\u003c\/li\u003e\n\u003cli\u003eBanana to BNC Adapter\u003c\/li\u003e\n\u003cli\u003ePower Adapter\u003c\/li\u003e\n\u003cli\u003eShield Test Leads with Black ground Leads\u003c\/li\u003e\n\u003cli\u003eTL175 Test Leads\u003c\/li\u003e\n\u003cli\u003eBattery\u003c\/li\u003e\n\u003cli\u003eWiFi Dongle\u003c\/li\u003e\n\u003cli\u003eLine Cord\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_ScopeMeter_Brochure_-_120_Series_190_Series.PDF?1800\" target=\"_blank\" title=\"Fluke 123B Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 123B Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-05-11T13:46:38-06:00","created_at":"2018-05-11T13:49:39-06:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":262479,"price_min":262479,"price_max":341767,"available":true,"price_varies":true,"compare_at_price":208100,"compare_at_price_min":208100,"compare_at_price_max":208100,"compare_at_price_varies":false,"variants":[{"id":30250850320427,"title":"FLU-123B\/NA","option1":"FLU-123B\/NA","option2":null,"option3":null,"sku":"FLU-123B\/NA","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 123B Industrial ScopeMeter® Hand-Held Oscilloscope, 2 Channel, 20MHz - FLU-123B\/NA","public_title":"FLU-123B\/NA","options":["FLU-123B\/NA"],"price":262479,"weight":4536,"compare_at_price":208100,"inventory_management":"shopify","barcode":"095969814737","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":30250853466155,"title":"FLU-123B\/NA\/S","option1":"FLU-123B\/NA\/S","option2":null,"option3":null,"sku":"FLU-123B\/NA\/S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 123B Industrial ScopeMeter® Hand-Held Oscilloscope, 2 Channel, 20MHz - FLU-123B\/NA\/S","public_title":"FLU-123B\/NA\/S","options":["FLU-123B\/NA\/S"],"price":341767,"weight":4536,"compare_at_price":208100,"inventory_management":"shopify","barcode":"095969814973","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Osciloscopio-ScopeMeter-Portatil-20-MHz-MPP-Fluke-123-008-6470888.jpg?v=1526068181"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Osciloscopio-ScopeMeter-Portatil-20-MHz-MPP-Fluke-123-008-6470888.jpg?v=1526068181","options":["Model"],"media":[{"alt":null,"id":1646713045035,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Osciloscopio-ScopeMeter-Portatil-20-MHz-MPP-Fluke-123-008-6470888.jpg?v=1526068181"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Osciloscopio-ScopeMeter-Portatil-20-MHz-MPP-Fluke-123-008-6470888.jpg?v=1526068181","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input digital oscilloscope and multimeter\u003c\/li\u003e\n\u003cli\u003e20 MHz oscilloscope bandwidth\u003c\/li\u003e\n\u003cli\u003eTwo 5,000-count true-rms digital multimeters\u003c\/li\u003e\n\u003cli\u003eConnect-and-View™ trigger simplicity for hands-off operation; IntellaSet™ technology automatically and intelligently adjusts numerical readout\u003c\/li\u003e\n\u003cli\u003eDual-input waveform and meter reading recorder for trending data over extended periods\u003c\/li\u003e\n\u003cli\u003eRecorder Event Detect captures elusive intermittent signals\u003c\/li\u003e\n\u003cli\u003eWiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app*\u003c\/li\u003e\n\u003cli\u003eFlukeView® ScopeMeter® Software for Windows® (FLU-123B\/NA\/S)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eTrigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScreen update\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFree run, on trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eA, B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eSensitivity A and B\u003c\/td\u003e\n\u003ctd\u003e@ DC to 5 MHz\u003c\/td\u003e\n\u003ctd\u003e0.5 divisions or 5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" rowspan=\"2\"\u003e@ 40 MHz\u003c\/td\u003e\n\u003ctd\u003e123B: 4 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 1.5 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" rowspan=\"2\"\u003e@ 60 MHz\u003c\/td\u003e\n\u003ctd\u003e123B: N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e124B and 125B: 4 divisions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlope\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePositive, negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAdvanced scope functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eDisplay modes\u003c\/td\u003e\n\u003ctd\u003eNormal\u003c\/td\u003e\n\u003ctd\u003eCaptures up to 25 ns glitches and displays analog-like persistence waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eSmooth\u003c\/td\u003e\n\u003ctd\u003eSuppresses noise from a waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eGlitch off\u003c\/td\u003e\n\u003ctd\u003eDoes not capture glitches between samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eEnvelope\u003c\/td\u003e\n\u003ctd\u003eRecords and displays the minimum and maximum of waveforms over time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto set (Connect-and-View™)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eContinuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eInput A and input B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eDC voltage (VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(0.5% +5 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection (CMRR)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;100 dB @ dc, \u0026gt;60 dB @ 50, 60, or 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eTrue-rms voltages (V ac and V ac+dc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 750 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy for 5% to 100% of range (DC coupled)\u003c\/td\u003e\n\u003ctd\u003eDC to 60 Hz (V ac+dc)\u003c\/td\u003e\n\u003ctd\u003e±(1% +10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e1 Hz to 60 Hz (V ac)\u003c\/td\u003e\n\u003ctd\u003e±(1% +10 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy for 5% to 100% of range (AC or dc coupled)\u003c\/td\u003e\n\u003ctd\u003e60 Hz to 20 kHz\u003c\/td\u003e\n\u003ctd\u003e±(2.5% +15 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC rejection (only VAC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;50 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eCommon mode rejection (CMRR)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;100 dB @ dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e\u0026gt;60 dB @ 50, 60, or 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5000 counts, reading is independent of any signal crest factor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003ePeak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMax peak, Min peak, or pk-to-pk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 mV, 5 V, 50 V, 500 V, 2200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eAccuracy Max peak or Min peak\u003c\/td\u003e\n\u003ctd\u003e5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eAccuracy Peak-to-Peak\u003c\/td\u003e\n\u003ctd\u003e10% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull scale reading\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eRecorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMeter readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Speed\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMaximum 2 measurement\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size (min, max, average)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 M readings for 1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eWaveform record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum sample rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 K sample\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize Internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 M samples Recorded Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 minutes at 500 μs\/div\u003cbr\u003e11 hours at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5 G samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e11 hours at 500 μs\/div\u003cbr\u003e14 days at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003ePower Quality (125B only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWatt, VA, var, PF, DPF, Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eWatt, VA, var ranges (auto)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e250 W to 250 MW, 625 MW, 1.56 GW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: total (% r)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 6 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: fundamental (% f)\u003c\/td\u003e\n\u003ctd\u003e±(4% + 4 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDPF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00, ±0.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10.0 Hz to 15.0 kHz\u003cbr\u003e40.0 Hz to 70.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Harmonics\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDC to 51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings \/ Cursor readings \u003cbr\u003e(fundamental 40 Hz to 70 Hz)\u003c\/td\u003e\n\u003ctd\u003eVrms \/ Arms \/Watt\u003c\/td\u003e\n\u003ctd\u003eEach harmonic from fundamental maybe selected for individual readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eIncludes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOscilloscope\u003c\/li\u003e\n\u003cli\u003eAccessory List\u003c\/li\u003e\n\u003cli\u003eCD\u003c\/li\u003e\n\u003cli\u003eSafety Manual\u003c\/li\u003e\n\u003cli\u003eBanana to BNC Adapter\u003c\/li\u003e\n\u003cli\u003ePower Adapter\u003c\/li\u003e\n\u003cli\u003eShield Test Leads with Black ground Leads\u003c\/li\u003e\n\u003cli\u003eTL175 Test Leads\u003c\/li\u003e\n\u003cli\u003eBattery\u003c\/li\u003e\n\u003cli\u003eWiFi Dongle\u003c\/li\u003e\n\u003cli\u003eLine Cord\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_ScopeMeter_Brochure_-_120_Series_190_Series.PDF?1800\" target=\"_blank\" title=\"Fluke 123B Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 123B Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 123B Industrial ScopeMeter® Hand-Held Oscilloscope, 2 Channel, 20MHz

Fluke 123B Industrial ScopeMeter® Hand-Held Oscilloscope, 2 Channel, 20MHz

$3,417.67 CAD

The compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with F...


More Info
{"id":1253590499371,"title":"Fluke 124B Industrial Hand-Held ScopeMeter Oscilloscope, 2 Channel, 40 MHZ","handle":"fluke-124-industrial-scopemeter","description":"\u003cp\u003e\u003cspan\u003eThe compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input digital oscilloscope and multimeter\u003c\/li\u003e\n\u003cli\u003eIncreased resolution and work load coverage with 40 MHz oscilloscope bandwidth\u003c\/li\u003e\n\u003cli\u003eTwo 5,000-count true-rms digital multimeters\u003c\/li\u003e\n\u003cli\u003eConnect-and-View™ trigger simplicity for hands-off operation; IntellaSet™ technology automatically and intelligently adjusts numerical readout\u003c\/li\u003e\n\u003cli\u003eDual-input waveform and meter reading recorder for trending data over extended periods\u003c\/li\u003e\n\u003cli\u003eRecorder Event Detect captures elusive intermittent signals\u003c\/li\u003e\n\u003cli\u003eWiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app*\u003c\/li\u003e\n\u003cli\u003eFlukeView® ScopeMeter® Software for Windows® (FLU-124\/B\/NA\/S)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOscilloscope\u003c\/li\u003e\n\u003cli\u003eAccessory List\u003c\/li\u003e\n\u003cli\u003eCD\u003c\/li\u003e\n\u003cli\u003eSafety Manual\u003c\/li\u003e\n\u003cli\u003eBanana to BNC Adapter\u003c\/li\u003e\n\u003cli\u003ePower Adapter\u003c\/li\u003e\n\u003cli\u003eShield Test Leads W\/ Black Ground Leads\u003c\/li\u003e\n\u003cli\u003eTL175 Test Leads\u003c\/li\u003e\n\u003cli\u003eBattery\u003c\/li\u003e\n\u003cli\u003eWiFi Dongle\u003c\/li\u003e\n\u003cli\u003eLine Cord\u003c\/li\u003e\n\u003cli\u003e10:1 Voltage Probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_ScopeMeter_Brochure_-_120_Series_190_Series.PDF?1800\" target=\"_blank\" title=\"Fluke 124B Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 124B Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-05-11T16:58:21-06:00","created_at":"2018-05-11T17:01:08-06:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":372775,"price_min":372775,"price_max":442815,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12050132172843,"title":"FLU-124B\/NA","option1":"FLU-124B\/NA","option2":null,"option3":null,"sku":"FLU-124B\/NA","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 124B Industrial Hand-Held ScopeMeter Oscilloscope, 2 Channel, 40 MHZ - FLU-124B\/NA","public_title":"FLU-124B\/NA","options":["FLU-124B\/NA"],"price":372775,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969814812","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":30251325653035,"title":"FLU-124B\/NA\/S","option1":"FLU-124B\/NA\/S","option2":null,"option3":null,"sku":"FLU-124B\/NA\/S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 124B Industrial Hand-Held ScopeMeter Oscilloscope, 2 Channel, 40 MHZ - FLU-124B\/NA\/S","public_title":"FLU-124B\/NA\/S","options":["FLU-124B\/NA\/S"],"price":442815,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969815055","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-124-846.jpg?v=1526079670"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-124-846.jpg?v=1526079670","options":["Model"],"media":[{"alt":null,"id":1647110881323,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-124-846.jpg?v=1526079670"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-124-846.jpg?v=1526079670","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input digital oscilloscope and multimeter\u003c\/li\u003e\n\u003cli\u003eIncreased resolution and work load coverage with 40 MHz oscilloscope bandwidth\u003c\/li\u003e\n\u003cli\u003eTwo 5,000-count true-rms digital multimeters\u003c\/li\u003e\n\u003cli\u003eConnect-and-View™ trigger simplicity for hands-off operation; IntellaSet™ technology automatically and intelligently adjusts numerical readout\u003c\/li\u003e\n\u003cli\u003eDual-input waveform and meter reading recorder for trending data over extended periods\u003c\/li\u003e\n\u003cli\u003eRecorder Event Detect captures elusive intermittent signals\u003c\/li\u003e\n\u003cli\u003eWiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app*\u003c\/li\u003e\n\u003cli\u003eFlukeView® ScopeMeter® Software for Windows® (FLU-124\/B\/NA\/S)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOscilloscope\u003c\/li\u003e\n\u003cli\u003eAccessory List\u003c\/li\u003e\n\u003cli\u003eCD\u003c\/li\u003e\n\u003cli\u003eSafety Manual\u003c\/li\u003e\n\u003cli\u003eBanana to BNC Adapter\u003c\/li\u003e\n\u003cli\u003ePower Adapter\u003c\/li\u003e\n\u003cli\u003eShield Test Leads W\/ Black Ground Leads\u003c\/li\u003e\n\u003cli\u003eTL175 Test Leads\u003c\/li\u003e\n\u003cli\u003eBattery\u003c\/li\u003e\n\u003cli\u003eWiFi Dongle\u003c\/li\u003e\n\u003cli\u003eLine Cord\u003c\/li\u003e\n\u003cli\u003e10:1 Voltage Probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_ScopeMeter_Brochure_-_120_Series_190_Series.PDF?1800\" target=\"_blank\" title=\"Fluke 124B Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 124B Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 124B Industrial Hand-Held ScopeMeter Oscilloscope, 2 Channel, 40 MHZ

Fluke 124B Industrial Hand-Held ScopeMeter Oscilloscope, 2 Channel, 40 MHZ

$4,428.15 CAD

The compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with F...


More Info
{"id":1253600526379,"title":"Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope, 2 Channel, 40 MHZ","handle":"fluke-125-industrial-scopemeter","description":"\u003cp\u003e\u003cspan\u003eThe compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input digital oscilloscope and multimeter\u003c\/li\u003e\n\u003cli\u003eIncreased resolution and work load coverage with 40 MHz oscilloscope bandwidth\u003c\/li\u003e\n\u003cli\u003eTwo 5,000-count true-rms digital multimeters\u003c\/li\u003e\n\u003cli\u003eConnect-and-View™ trigger simplicity for hands-off operation; IntellaSet™ technology automatically and intelligently adjusts numerical readout\u003c\/li\u003e\n\u003cli\u003eDual-input waveform and meter reading recorder for trending data over extended periods\u003c\/li\u003e\n\u003cli\u003eRecorder Event Detect captures elusive intermittent signals\u003c\/li\u003e\n\u003cli\u003eWiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app*\u003c\/li\u003e\n\u003cli\u003eFlukeView® ScopeMeter® Software for Windows® (FLU-125B\/NA\/S)\u003c\/li\u003e\n\u003cli\u003eCheck Industrial networks with BusHealth physical layer tests against defined reference levels\u003c\/li\u003e\n\u003cli\u003eSingle Phase Power Quality and Harmonics Analzyer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications \u003cspan style=\"font-size: 1.4em;\"\u003e \u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e See Resources for Product Data Sheet\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eRecorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMeter readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Speed\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMaximum 2 measurement\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size (min, max, average)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 M readings for 1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eWaveform record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum sample rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 K sample\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize Internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 M samples Recorded Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 minutes at 500 μs\/div\u003cbr\u003e11 hours at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5 G samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e11 hours at 500 μs\/div\u003cbr\u003e14 days at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003ePower Quality (125B only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWatt, VA, var, PF, DPF, Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eWatt, VA, var ranges (auto)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e250 W to 250 MW, 625 MW, 1.56 GW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: total (% r)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 6 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: fundamental (% f)\u003c\/td\u003e\n\u003ctd\u003e±(4% + 4 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDPF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00, ±0.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10.0 Hz to 15.0 kHz\u003cbr\u003e40.0 Hz to 70.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Harmonics\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDC to 51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings \/ Cursor readings \u003cbr\u003e(fundamental 40 Hz to 70 Hz)\u003c\/td\u003e\n\u003ctd\u003eVrms \/ Arms \/Watt\u003c\/td\u003e\n\u003ctd\u003eEach harmonic from fundamental maybe selected for individual readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eIncludes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"font-size: 1.4em;\"\u003e \u003c\/span\u003e\u003cspan style=\"font-size: 1.4em;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOscilloscope\u003c\/li\u003e\n\u003cli\u003eAccessory List\u003c\/li\u003e\n\u003cli\u003eCD\u003c\/li\u003e\n\u003cli\u003eSafety Manual\u003c\/li\u003e\n\u003cli\u003eBanana to BNC Adapter\u003c\/li\u003e\n\u003cli\u003ePower Adapter\u003c\/li\u003e\n\u003cli\u003eShield Test Leads W\/ Black Ground Leads\u003c\/li\u003e\n\u003cli\u003eTL175 Test Leads\u003c\/li\u003e\n\u003cli\u003eBattery\u003c\/li\u003e\n\u003cli\u003eWiFi Dongle\u003c\/li\u003e\n\u003cli\u003eLine Cord\u003c\/li\u003e\n\u003cli\u003e10:1 Voltage probe\u003c\/li\u003e\n\u003cli\u003eCurrent Clamp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_ScopeMeter_Brochure_-_120_Series_190_Series.PDF?1800\" target=\"_blank\" title=\"Fluke 125B Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 125B Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-05-11T17:01:32-06:00","created_at":"2018-05-11T17:03:43-06:00","vendor":"Fluke","type":"Oscilloscopes","tags":[],"price":457095,"price_min":457095,"price_max":525775,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":12050314723371,"title":"FLU-125B\/NA","option1":"FLU-125B\/NA","option2":null,"option3":null,"sku":"FLU-125B\/NA","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope, 2 Channel, 40 MHZ - FLU-125B\/NA","public_title":"FLU-125B\/NA","options":["FLU-125B\/NA"],"price":457095,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969814898","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":30251356618795,"title":"FLU-125B\/NA\/S","option1":"FLU-125B\/NA\/S","option2":null,"option3":null,"sku":"FLU-125B\/NA\/S","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope, 2 Channel, 40 MHZ - FLU-125B\/NA\/S","public_title":"FLU-125B\/NA\/S","options":["FLU-125B\/NA\/S"],"price":525775,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969815130","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-125-1ce.jpg?v=1526079825"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-125-1ce.jpg?v=1526079825","options":["Model"],"media":[{"alt":null,"id":1647120023595,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-125-1ce.jpg?v=1526079825"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-125-1ce.jpg?v=1526079825","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDual-input digital oscilloscope and multimeter\u003c\/li\u003e\n\u003cli\u003eIncreased resolution and work load coverage with 40 MHz oscilloscope bandwidth\u003c\/li\u003e\n\u003cli\u003eTwo 5,000-count true-rms digital multimeters\u003c\/li\u003e\n\u003cli\u003eConnect-and-View™ trigger simplicity for hands-off operation; IntellaSet™ technology automatically and intelligently adjusts numerical readout\u003c\/li\u003e\n\u003cli\u003eDual-input waveform and meter reading recorder for trending data over extended periods\u003c\/li\u003e\n\u003cli\u003eRecorder Event Detect captures elusive intermittent signals\u003c\/li\u003e\n\u003cli\u003eWiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect® mobile app*\u003c\/li\u003e\n\u003cli\u003eFlukeView® ScopeMeter® Software for Windows® (FLU-125B\/NA\/S)\u003c\/li\u003e\n\u003cli\u003eCheck Industrial networks with BusHealth physical layer tests against defined reference levels\u003c\/li\u003e\n\u003cli\u003eSingle Phase Power Quality and Harmonics Analzyer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications \u003cspan style=\"font-size: 1.4em;\"\u003e \u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e See Resources for Product Data Sheet\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eRecorder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eThe results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMeter readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Speed\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eMaximum 2 measurement\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size (min, max, average)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 M readings for 1 channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eWaveform record\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum sample rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 K sample\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize Internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e400 M samples Recorded Time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan internal memory\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 minutes at 500 μs\/div\u003cbr\u003e11 hours at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecord Size SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5 G samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorded Time Span SD card\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e11 hours at 500 μs\/div\u003cbr\u003e14 days at 20 ms\/div\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of events\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003ePower Quality (125B only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eWatt, VA, var, PF, DPF, Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eWatt, VA, var ranges (auto)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e250 W to 250 MW, 625 MW, 1.56 GW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: total (% r)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 6 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eWhen selected: fundamental (% f)\u003c\/td\u003e\n\u003ctd\u003e±(4% + 4 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDPF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePF\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.00 to 1.00, ±0.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10.0 Hz to 15.0 kHz\u003cbr\u003e40.0 Hz to 70.0 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Harmonics\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDC to 51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadings \/ Cursor readings \u003cbr\u003e(fundamental 40 Hz to 70 Hz)\u003c\/td\u003e\n\u003ctd\u003eVrms \/ Arms \/Watt\u003c\/td\u003e\n\u003ctd\u003eEach harmonic from fundamental maybe selected for individual readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"3\"\u003eIncludes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"font-size: 1.4em;\"\u003e \u003c\/span\u003e\u003cspan style=\"font-size: 1.4em;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOscilloscope\u003c\/li\u003e\n\u003cli\u003eAccessory List\u003c\/li\u003e\n\u003cli\u003eCD\u003c\/li\u003e\n\u003cli\u003eSafety Manual\u003c\/li\u003e\n\u003cli\u003eBanana to BNC Adapter\u003c\/li\u003e\n\u003cli\u003ePower Adapter\u003c\/li\u003e\n\u003cli\u003eShield Test Leads W\/ Black Ground Leads\u003c\/li\u003e\n\u003cli\u003eTL175 Test Leads\u003c\/li\u003e\n\u003cli\u003eBattery\u003c\/li\u003e\n\u003cli\u003eWiFi Dongle\u003c\/li\u003e\n\u003cli\u003eLine Cord\u003c\/li\u003e\n\u003cli\u003e10:1 Voltage probe\u003c\/li\u003e\n\u003cli\u003eCurrent Clamp\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_ScopeMeter_Brochure_-_120_Series_190_Series.PDF?1800\" target=\"_blank\" title=\"Fluke 125B Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 125B Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope, 2 Channel, 40 MHZ

Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope, 2 Channel, 40 MHZ

$5,257.75 CAD

The compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It's a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with F...


More Info
Fluke 1503 Insulation Resistance Tester

Insulation Testers

$990.07 CAD
{"id":1076161151019,"title":"Fluke 1503 Insulation Resistance Tester","handle":"fluke-1503-insulation-resistance-tester","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 1503 is a great choice for basic residential and commercial electrical insulation testing. This rugged, compact tool fits in the palm of your hand. The 1503 is the same form factor as the Fluke 1507 but with a few less features. You can count on it to handle the most common tests at a most affordable price. Additional features, like the remote probe, reduce the time needed to perform repetitive testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eA rugged, compact insulation resistance tester for residential and commercial electricians\u003c\/li\u003e\n\u003cli\u003ePerforms insulation tests from 0.01 MΩ to 2000 MΩ\u003c\/li\u003e\n\u003cli\u003eOffers two insulation test voltages: 500 V and 1000 V\u003c\/li\u003e\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli\u003eMeasures resistance from 0.01 Ω to 20.00 kΩ\\\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures AC\/DC voltage from 0.1 V to 600 V\u003c\/li\u003e\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli\u003eProvides lo-ohms earth-bond continuity (200 mA)\u003c\/li\u003e\n\u003cli\u003eSimplifies repetitive or hard-to-reach testing with the remote test probe\u003c\/li\u003e\n\u003cli\u003eSaves battery power with auto power off\u003c\/li\u003e\n\u003cli\u003ePresents results on a large, backlit display\u003c\/li\u003e\n\u003cli\u003eFeatures CAT IV 600 V overvoltage category rating\u003c\/li\u003e\n\u003cli\u003eComes with remote probe, test leads, test probes, alligator clips, and one-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC\/DC Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 Hz to 400 Hz ±(% of Rdg + Digits)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 MΩ (nominal), \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio (1 kΩ unbalanced)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 60 dB at DC, 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEarth Bond Resistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e20.00 Ω\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200.0 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003e1.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit test voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 4.0 V, \u0026lt; 8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 200.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInsulation Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 MΩ to 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+ 20%, - 0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto discharge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDischarge time \u0026lt; 0.5 second for C = 1 µF or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive circuit indicator\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInhibit test if terminal voltage \u0026gt; 30 V prior to initialization of test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOperable with up to 1 µF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eMeasure accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage applied to any terminal:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V AC rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.05 x (specified accuracy) per °C for temperatures \u0026lt; 18°C or \u0026gt; 28°C (\u0026lt; 64°F or \u0026gt; 82°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRelative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 95% @ 10°C to 30°C (50°F to 86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 75% @ 30°C to 40°C (86°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 40% @ 40°C to 55°C (104°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIn an RF field of 3 V\/M, accuracy = specified accuracy (EN 61326-1:1997)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eComplies with ANSI\/ISA 82.02.01 (61010-1) 2004, CAN\/CSA-C22.2 NO. 61010-1-04, and IEC\/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA per standard CSA\/CAN C22.2 No. 61010.1-04; TUV per standard IEC\/EN 61010-1 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFour AA batteries (NEDA 15A or IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery llife\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eInsulation test use:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance measurements:\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOperating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m CAT IV 600 V, 3000 m CAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating (storage)\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-range capability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e110% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded accessories\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1503 Insulation Tester\u003c\/li\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eTest probes\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1507_and_1503_Spec.pdf?1803\" target=\"_blank\" title=\"Fluke 1503 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1503 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2018-03-07T12:57:54-07:00","created_at":"2018-03-07T13:24:58-07:00","vendor":"Fluke","type":"Insulation Testers","tags":[],"price":99007,"price_min":99007,"price_max":99007,"available":true,"price_varies":false,"compare_at_price":70700,"compare_at_price_min":70700,"compare_at_price_max":70700,"compare_at_price_varies":false,"variants":[{"id":11042039562283,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-1503","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1503 Insulation Resistance Tester","public_title":null,"options":["Default Title"],"price":99007,"weight":2268,"compare_at_price":70700,"inventory_management":"shopify","barcode":"095969288668","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1503_BHD.jpg?v=1520454300"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1503_BHD.jpg?v=1520454300","options":["Title"],"media":[{"alt":null,"id":1475812065323,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1503_BHD.jpg?v=1520454300"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1503_BHD.jpg?v=1520454300","width":1200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 1503 is a great choice for basic residential and commercial electrical insulation testing. This rugged, compact tool fits in the palm of your hand. The 1503 is the same form factor as the Fluke 1507 but with a few less features. You can count on it to handle the most common tests at a most affordable price. Additional features, like the remote probe, reduce the time needed to perform repetitive testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eA rugged, compact insulation resistance tester for residential and commercial electricians\u003c\/li\u003e\n\u003cli\u003ePerforms insulation tests from 0.01 MΩ to 2000 MΩ\u003c\/li\u003e\n\u003cli\u003eOffers two insulation test voltages: 500 V and 1000 V\u003c\/li\u003e\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli\u003eMeasures resistance from 0.01 Ω to 20.00 kΩ\\\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasures AC\/DC voltage from 0.1 V to 600 V\u003c\/li\u003e\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli\u003eProvides lo-ohms earth-bond continuity (200 mA)\u003c\/li\u003e\n\u003cli\u003eSimplifies repetitive or hard-to-reach testing with the remote test probe\u003c\/li\u003e\n\u003cli\u003eSaves battery power with auto power off\u003c\/li\u003e\n\u003cli\u003ePresents results on a large, backlit display\u003c\/li\u003e\n\u003cli\u003eFeatures CAT IV 600 V overvoltage category rating\u003c\/li\u003e\n\u003cli\u003eComes with remote probe, test leads, test probes, alligator clips, and one-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC\/DC Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 Hz to 400 Hz ±(% of Rdg + Digits)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 MΩ (nominal), \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio (1 kΩ unbalanced)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 60 dB at DC, 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEarth Bond Resistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e20.00 Ω\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200.0 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003e1.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit test voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 4.0 V, \u0026lt; 8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 200.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInsulation Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 MΩ to 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+ 20%, - 0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto discharge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDischarge time \u0026lt; 0.5 second for C = 1 µF or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive circuit indicator\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInhibit test if terminal voltage \u0026gt; 30 V prior to initialization of test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOperable with up to 1 µF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eMeasure accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage applied to any terminal:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V AC rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.05 x (specified accuracy) per °C for temperatures \u0026lt; 18°C or \u0026gt; 28°C (\u0026lt; 64°F or \u0026gt; 82°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRelative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 95% @ 10°C to 30°C (50°F to 86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 75% @ 30°C to 40°C (86°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 40% @ 40°C to 55°C (104°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIn an RF field of 3 V\/M, accuracy = specified accuracy (EN 61326-1:1997)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eComplies with ANSI\/ISA 82.02.01 (61010-1) 2004, CAN\/CSA-C22.2 NO. 61010-1-04, and IEC\/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA per standard CSA\/CAN C22.2 No. 61010.1-04; TUV per standard IEC\/EN 61010-1 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFour AA batteries (NEDA 15A or IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery llife\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eInsulation test use:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance measurements:\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOperating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m CAT IV 600 V, 3000 m CAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating (storage)\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-range capability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e110% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded accessories\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1503 Insulation Tester\u003c\/li\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eTest probes\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1507_and_1503_Spec.pdf?1803\" target=\"_blank\" title=\"Fluke 1503 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1503 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e"}
Fluke 1503 Insulation Resistance Tester

Fluke 1503 Insulation Resistance Tester

$990.07 CAD

The Fluke 1503 is a great choice for basic residential and commercial electrical insulation testing. This rugged, compact tool fits in the palm of your hand. The 1503 is the same form factor as the Fluke 1507 but with a few less features. You can count on it to handle the most common tests at a most affordable price. Additional features, like t...


More Info
Fluke 1507 Insulation Resistance Tester

Insulation Testers

$1,165.51 CAD
{"id":1076405272619,"title":"Fluke 1507 Insulation Resistance Tester","handle":"fluke-1507-insulation-resistance-tester","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications.\u003c\/p\u003e\n\u003cp\u003eTake advantage of the 1507 full feature set to easily and quickly perform advanced insulation resistance testing. Its handy size and light weight make it easy to pack and use. Additional features, like the remote probe, save both time and money especially when performing repetitive tests. And its reasonable price and rugged reliability make it an excellent value.\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRugged, compact advanced insulation resistance tester for electrical contractors and industrial and commercial electricians\u003c\/li\u003e\n\u003cli\u003eAutomatically calculates Polarization Index and Dielectric Absorption Ratio\u003c\/li\u003e\n\u003cli\u003eMakes repetitive tests simple and easy with a Compare (Pass\/Fail) function \u003c\/li\u003e\n\u003cli\u003eOffers multiple insulation test voltages: 50 V, 100 V, 250 V, 500 V, and  1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePerforms insulation tests from 0.01 MΩ to 2.0 GΩ\u003c\/li\u003e\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage from 0.1 V to 600 V and resistance from 0.01 Ω to 20.00 kΩ\u003c\/li\u003e\n\u003cli\u003eProvides lo-ohms earth-bond continuity (200 mA)\u003c\/li\u003e\n\u003cli\u003eSimplifies repetitive or hard-to-reach testing with the remote test probe\u003c\/li\u003e\n\u003cli\u003eSaves battery power with auto power off\u003c\/li\u003e\n\u003cli\u003ePresents results on a large, backlit display\u003c\/li\u003e\n\u003cli\u003eFeatures CAT IV 600 V overvoltage category rating\u003c\/li\u003e\n\u003cli\u003eComes with remote probe, test leads, test probes, alligator clips and one-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC\/DC Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 Hz to 400 Hz ± (% of Rdg + Digits)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 MΩ (nominal), \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio (1 kΩ unbalanced):\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 60 dB at DC, 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEarth Bond Resistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e20.00 Ω\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200.0 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003e1.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit test voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 4.0 V, \u0026lt; 8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 200.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInsulation Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+ 20%, - 0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto discharge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDischarge time \u0026lt; 0.5 second for C = 1 µF or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive circuit indicator\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInhibit test if terminal voltage \u0026gt; 30 V prior to initialization of test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOperable with up to 1 µF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eMeasure accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e50 V\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage applied to any terminal:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V AC rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.05 x (specified accuracy) per °C for temperatures \u0026lt; 18°C or \u0026gt; 28°C (\u0026lt; 64°F or \u0026gt; 82°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRelative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 95% @ 10°C to 30°C (50°F to 86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 75% @ 30°C to 40°C (86°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 40% @ 40°C to 55°C (104°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIn an RF field of 3 V\/M, accuracy = specified accuracy (EN 61326-1:1997)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eComplies with ANSI\/ISA 82.02.01 (61010-1) 2004, CAN\/CSA-C22.2 NO. 61010-1-04, and IEC\/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA per standard CSA\/CAN C22.2 No. 61010.1-04; TUV per standard IEC\/EN 61010-1 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFour AA batteries (NEDA 15A or IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eInsulation test use:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance measurements:\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOperating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m CAT IV 600 V, 3000 m CAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating (storage)\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-range capability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e110% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded accessories\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1507 Insulation Tester\u003c\/li\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eTest probes\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1507_and_1503_Spec.pdf?1803\" target=\"_blank\" title=\"Fluke 1507 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1507 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2018-03-07T15:10:22-07:00","created_at":"2018-03-07T15:13:21-07:00","vendor":"Fluke","type":"Insulation Testers","tags":[],"price":116551,"price_min":116551,"price_max":116551,"available":true,"price_varies":false,"compare_at_price":84000,"compare_at_price_min":84000,"compare_at_price_max":84000,"compare_at_price_varies":false,"variants":[{"id":11043776004139,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-1507","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1507 Insulation Resistance Tester","public_title":null,"options":["Default Title"],"price":116551,"weight":2268,"compare_at_price":84000,"inventory_management":"shopify","barcode":"095969288675","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke1507-2.png?v=1520460804"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke1507-2.png?v=1520460804","options":["Title"],"media":[{"alt":null,"id":1476022861867,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1050,"width":1050,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke1507-2.png?v=1520460804"},"aspect_ratio":1.0,"height":1050,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke1507-2.png?v=1520460804","width":1050}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications.\u003c\/p\u003e\n\u003cp\u003eTake advantage of the 1507 full feature set to easily and quickly perform advanced insulation resistance testing. Its handy size and light weight make it easy to pack and use. Additional features, like the remote probe, save both time and money especially when performing repetitive tests. And its reasonable price and rugged reliability make it an excellent value.\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRugged, compact advanced insulation resistance tester for electrical contractors and industrial and commercial electricians\u003c\/li\u003e\n\u003cli\u003eAutomatically calculates Polarization Index and Dielectric Absorption Ratio\u003c\/li\u003e\n\u003cli\u003eMakes repetitive tests simple and easy with a Compare (Pass\/Fail) function \u003c\/li\u003e\n\u003cli\u003eOffers multiple insulation test voltages: 50 V, 100 V, 250 V, 500 V, and  1000 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOther useful capabilities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePerforms insulation tests from 0.01 MΩ to 2.0 GΩ\u003c\/li\u003e\n\u003cli\u003eIncludes live circuit detection to prevent insulation test if voltage \u0026gt;30 V is detected\u003c\/li\u003e\n\u003cli\u003eIncludes auto-discharge of capacitive voltage for added user protection\u003c\/li\u003e\n\u003cli\u003eMeasures AC\/DC voltage from 0.1 V to 600 V and resistance from 0.01 Ω to 20.00 kΩ\u003c\/li\u003e\n\u003cli\u003eProvides lo-ohms earth-bond continuity (200 mA)\u003c\/li\u003e\n\u003cli\u003eSimplifies repetitive or hard-to-reach testing with the remote test probe\u003c\/li\u003e\n\u003cli\u003eSaves battery power with auto power off\u003c\/li\u003e\n\u003cli\u003ePresents results on a large, backlit display\u003c\/li\u003e\n\u003cli\u003eFeatures CAT IV 600 V overvoltage category rating\u003c\/li\u003e\n\u003cli\u003eComes with remote probe, test leads, test probes, alligator clips and one-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eAC\/DC Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRange\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e600.0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 Hz to 400 Hz ± (% of Rdg + Digits)\u003c\/td\u003e\n\u003ctd\u003e±(2% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 MΩ (nominal), \u0026lt; 100 pF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection ratio (1 kΩ unbalanced):\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 60 dB at DC, 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eEarth Bond Resistance Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRange\/Resolution\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e20.00 Ω\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e200.0 Ω\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2000 Ω\u003c\/td\u003e\n\u003ctd\u003e1.0 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20.00 kΩ\u003c\/td\u003e\n\u003ctd\u003e0.01 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(1.5% + 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 V rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit test voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 4.0 V, \u0026lt; 8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt; 200.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eInsulation Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 MΩ to 10 GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e+ 20%, - 0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto discharge\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDischarge time \u0026lt; 0.5 second for C = 1 µF or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive circuit indicator\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInhibit test if terminal voltage \u0026gt; 30 V prior to initialization of test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum capacitive load\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOperable with up to 1 µF load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eMeasure accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e50 V\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 V\u003c\/td\u003e\n\u003ctd\u003e±(3% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage applied to any terminal:\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e600 V AC rms or DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.05 x (specified accuracy) per °C for temperatures \u0026lt; 18°C or \u0026gt; 28°C (\u0026lt; 64°F or \u0026gt; 82°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRelative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 95% @ 10°C to 30°C (50°F to 86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 75% @ 30°C to 40°C (86°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e0% to 40% @ 40°C to 55°C (104°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIn an RF field of 3 V\/M, accuracy = specified accuracy (EN 61326-1:1997)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eComplies with ANSI\/ISA 82.02.01 (61010-1) 2004, CAN\/CSA-C22.2 NO. 61010-1-04, and IEC\/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCSA per standard CSA\/CAN C22.2 No. 61010.1-04; TUV per standard IEC\/EN 61010-1 2nd Edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eFour AA batteries (NEDA 15A or IEC LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eInsulation test use:\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance measurements:\u003c\/td\u003e\n\u003ctd\u003eTester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize (H x W x L)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e550 g (1.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP rating\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eOperating\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m CAT IV 600 V, 3000 m CAT III 600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-operating (storage)\u003c\/td\u003e\n\u003ctd\u003e12,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver-range capability\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e110% of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded accessories\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1507 Insulation Tester\u003c\/li\u003e\n\u003cli\u003eRemote probe\u003c\/li\u003e\n\u003cli\u003eTest leads\u003c\/li\u003e\n\u003cli\u003eTest probes\u003c\/li\u003e\n\u003cli\u003eAlligator clips\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1507_and_1503_Spec.pdf?1803\" target=\"_blank\" title=\"Fluke 1507 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1507 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e"}
Fluke 1507 Insulation Resistance Tester

Fluke 1507 Insulation Resistance Tester

$1,165.51 CAD

The Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications. Take advantage of the 1507 full feature set to easily and quickly perform advanced ins...


More Info
Fluke 154 HART Calibration Assistant

Communicators

$7,547.99 CAD
{"id":1076645855275,"title":"Fluke 154 HART Calibration Assistant","handle":"fluke-154-hart-calibration-assistant","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe Fluke 154 is a standalone tablet based HART® communication tool. Combine with a Fluke 750 or 720 Series for a complete HART calibration and configuration solution.\u003c\/span\u003e","published_at":"2018-03-07T16:49:30-07:00","created_at":"2018-03-07T16:51:32-07:00","vendor":"Fluke","type":"Communicators","tags":[],"price":754799,"price_min":754799,"price_max":754799,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11044805935147,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-154","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 154 HART Calibration Assistant","public_title":null,"options":["Default Title"],"price":754799,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke154.jpg?v=1520466694","\/\/kingswayinstruments.com\/cdn\/shop\/products\/984a1560-185a-4e22-be1d-57748cb38095.jpg._CB296742191.jpg?v=1520466695"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke154.jpg?v=1520466694","options":["Title"],"media":[{"alt":null,"id":1476238901291,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke154.jpg?v=1520466694"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke154.jpg?v=1520466694","width":1024},{"alt":null,"id":1476238934059,"position":2,"preview_image":{"aspect_ratio":1.286,"height":1166,"width":1500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/984a1560-185a-4e22-be1d-57748cb38095.jpg._CB296742191.jpg?v=1520466695"},"aspect_ratio":1.286,"height":1166,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/984a1560-185a-4e22-be1d-57748cb38095.jpg._CB296742191.jpg?v=1520466695","width":1500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe Fluke 154 is a standalone tablet based HART® communication tool. Combine with a Fluke 750 or 720 Series for a complete HART calibration and configuration solution.\u003c\/span\u003e"}
Fluke 154 HART Calibration Assistant

Fluke 154 HART Calibration Assistant

$7,547.99 CAD

The Fluke 154 is a standalone tablet based HART® communication tool. Combine with a Fluke 750 or 720 Series for a complete HART calibration and configuration solution.


More Info
Fluke 1550C 5kV Digital Insulation Tester

Insulation Testers

From $8,567.99 CAD
{"id":1038411464747,"title":"Fluke 1550C 5kV Digital Insulation Tester","handle":"fluke-1550c-5kv-insulation-resistance-tester","description":"\u003cp\u003e\u003cspan\u003eThe Fluke 1550C performs digital insulation testing up to 5 kV, and makes the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTrust the best name in the business for all your insulation testing with the Fluke 1550C. With advanced testing methods, reporting, and best-in-class performance, this is the number one insulation tester in the industry. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage (DC)\u003c\/td\u003e\n\u003ctd\u003eRange (DC)\u003c\/td\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e250 kΩ to 5 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 GΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 50 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e500 kΩ to 10 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 GΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 100 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e1 MΩ to 20 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20 GΩ to 200 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 200 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e50 GΩ to 500 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 500 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 MΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e100 GΩ to 1 TΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 1 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLeakage Current Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 nA to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (5 % + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCapacitance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 uF to 15.00°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (15 % rdg + 0.03°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest cables with alligator clips (red, black, green)\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC power cord\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eEnglish manual\u003c\/li\u003e\n\u003cli\u003eUser's manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eQuick reference card\u003c\/li\u003e\n\u003cli\u003eSoftware license agreement\u003c\/li\u003e\n\u003cli\u003eRegistration card\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms installation guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR cable installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1550-1555_Spec.pdf?1595\" target=\"_blank\" title=\"Fluke 1550C Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1550C Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-02-21T14:50:18-07:00","created_at":"2018-02-21T14:54:58-07:00","vendor":"Fluke","type":"Insulation Testers","tags":[],"price":856799,"price_min":856799,"price_max":943295,"available":true,"price_varies":true,"compare_at_price":653300,"compare_at_price_min":653300,"compare_at_price_max":653300,"compare_at_price_varies":false,"variants":[{"id":10706613174315,"title":"1550C","option1":"1550C","option2":null,"option3":null,"sku":"FLU-1550C","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1550C 5kV Digital Insulation Tester - 1550C","public_title":"1550C","options":["1550C"],"price":856799,"weight":6804,"compare_at_price":653300,"inventory_management":"shopify","barcode":"095969550918","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16793563627563,"title":"1550C\/KIT","option1":"1550C\/KIT","option2":null,"option3":null,"sku":"FLU-1550C\/KIT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1550C 5kV Digital Insulation Tester - 1550C\/KIT","public_title":"1550C\/KIT","options":["1550C\/KIT"],"price":943295,"weight":6804,"compare_at_price":653300,"inventory_management":"shopify","barcode":"095969550987","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16793569198123,"title":"1550C FC","option1":"1550C FC","option2":null,"option3":null,"sku":"FLU-1550C FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1550C 5kV Digital Insulation Tester - 1550C FC","public_title":"1550C FC","options":["1550C FC"],"price":872167,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969868785","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C.jpg?v=1562783826","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C_BHD.jpg?v=1562783826","\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-1550c-01b-s.jpg?v=1562783826"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C.jpg?v=1562783826","options":["Model"],"media":[{"alt":null,"id":2797304807467,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C.jpg?v=1562783826"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C.jpg?v=1562783826","width":800},{"alt":null,"id":1417403858987,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C_BHD.jpg?v=1562783826"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1550C_BHD.jpg?v=1562783826","width":1200},{"alt":null,"id":1417412182059,"position":3,"preview_image":{"aspect_ratio":1.493,"height":402,"width":600,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-1550c-01b-s.jpg?v=1562783826"},"aspect_ratio":1.493,"height":402,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/F-1550c-01b-s.jpg?v=1562783826","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eThe Fluke 1550C performs digital insulation testing up to 5 kV, and makes the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTrust the best name in the business for all your insulation testing with the Fluke 1550C. With advanced testing methods, reporting, and best-in-class performance, this is the number one insulation tester in the industry. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage (DC)\u003c\/td\u003e\n\u003ctd\u003eRange (DC)\u003c\/td\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e250 kΩ to 5 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 GΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 50 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e500 kΩ to 10 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 GΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 100 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e1 MΩ to 20 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20 GΩ to 200 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 200 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e50 GΩ to 500 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 500 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 MΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e100 GΩ to 1 TΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 1 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLeakage Current Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 nA to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (5 % + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCapacitance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 uF to 15.00°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (15 % rdg + 0.03°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest cables with alligator clips (red, black, green)\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC power cord\u003c\/li\u003e\n\u003cli\u003eSoft carrying case\u003c\/li\u003e\n\u003cli\u003eEnglish manual\u003c\/li\u003e\n\u003cli\u003eUser's manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eQuick reference card\u003c\/li\u003e\n\u003cli\u003eSoftware license agreement\u003c\/li\u003e\n\u003cli\u003eRegistration card\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms installation guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR cable installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1550-1555_Spec.pdf?1595\" target=\"_blank\" title=\"Fluke 1550C Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1550C Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 1550C 5kV Digital Insulation Tester

Fluke 1550C 5kV Digital Insulation Tester

$8,721.67 CAD

The Fluke 1550C performs digital insulation testing up to 5 kV, and makes the perfect tool for preventive or predictive maintenance programs designed to identify potential equipment failures before they occur.  Trust the best name in the business for all your insulation testing with the Fluke 1550C. With advanced testing methods, reporting, and ...


More Info
{"id":1843599114283,"title":"Fluke 1551A RTD Stik Thermometer \u0026 Temperature Calibrator","handle":"fluke-1551a-rtd-stik-thermometer-temperature-calibrator","description":"\u003cp\u003e\u003cspan\u003eIntrinsically-safe, battery operated, portable reference thermometer designed to go where you work; whether working outdoors in environments where potentially explosive gases may be present or on the floor of a processing plant. Available in 9\", 12\", or 20\" lengths with optional datalogging.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically safe (ATEX and IECEx compliant)\u003c\/li\u003e\n\u003cli\u003eStainless steel probe and digital readout are fixed together and calibrated as a system\u003c\/li\u003e\n\u003cli\u003eAccuracy of ±0.05°C (±0.09°F) over full range\u003c\/li\u003e\n\u003cli\u003eLarge backlit LCD display rotates 90° making it easy to read from any angle\u003c\/li\u003e\n\u003cli\u003eUser-configurable temperature trend\/stability indicator lets you know when your temperature is stable enough to record an accurate measurement\u003c\/li\u003e\n\u003cli\u003eDisplay temperature in °C or °F\u003c\/li\u003e\n\u003cli\u003eUser-selectable resolution (0.1, 0.01, 0.001)\u003c\/li\u003e\n\u003cli\u003eMax\/Min\/Trend\/Up key allows you to see the maximum or minimum temperature since the most recent power up\u003c\/li\u003e\n\u003cli\u003eSimple three-point calibration function allows you to easily and accurately calibrate the thermometer\u003c\/li\u003e\n\u003cli\u003eRequires a minimum immersion depth of only 7cm (2.8\"), with no appreciable effect on the measured temperature due to heat loss through stem conduction\u003c\/li\u003e\n\u003cli\u003eData logging to internal memory of up to 10,000 time-stamped measurements is optionally available\u003c\/li\u003e\n\u003cli\u003e300-hour battery life\u003c\/li\u003e\n\u003cli\u003ePercent battery-life and low-battery indicator\u003c\/li\u003e\n\u003cli\u003eNVLAP-accredited, NIST-traceable calibration included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e-50°C to 160°C\u003cbr\u003e(-58°F to 320°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (1 year)\u003c\/td\u003e\n\u003ctd\u003e±0.05°C (±0.09°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay units\u003c\/td\u003e\n\u003ctd\u003e°C, °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor type\u003c\/td\u003e\n\u003ctd\u003e100 Ω thin-film RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe temperature coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00385 Ω\/Ω\/°C nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor length\u003c\/td\u003e\n\u003ctd\u003e≤ 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor position (from sheath tip)\u003c\/td\u003e\n\u003ctd\u003e3 mm (0.1 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum immersion depth\u003c\/td\u003e\n\u003ctd\u003e7 cm (2.8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe sheath material\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e4.8 mm diameter probe (3\/16 in): 14 seconds\u003cbr\u003e6.35 mm diameter probe (1\/4 in): 21 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe hysteresis\u003c\/td\u003e\n\u003ctd\u003e±0.01°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature resolution\u003c\/td\u003e\n\u003ctd\u003eSelectable: 0.1, 0.01, 0.001 (default 0.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1551A RTD Stik Thermometer (9\", 12\" or 20\" Length)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1551A.PDF?1804\" target=\"_blank\" title=\"Fluke 1551A Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1551A Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-07-30T08:45:13-06:00","created_at":"2019-07-30T08:59:52-06:00","vendor":"Fluke","type":"RTDs","tags":[],"price":119408,"price_min":119408,"price_max":139672,"available":true,"price_varies":true,"compare_at_price":112000,"compare_at_price_min":112000,"compare_at_price_max":122700,"compare_at_price_varies":true,"variants":[{"id":16825570656299,"title":"1551A-12 : 12\" Length","option1":"1551A-12 : 12\" Length","option2":null,"option3":null,"sku":"FLU-1551A-12","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1551A RTD Stik Thermometer \u0026 Temperature Calibrator - 1551A-12 : 12\" Length","public_title":"1551A-12 : 12\" Length","options":["1551A-12 : 12\" Length"],"price":119408,"weight":2268,"compare_at_price":112000,"inventory_management":"shopify","barcode":"095969546263","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16825570623531,"title":"1551A-9 : 9\" Length","option1":"1551A-9 : 9\" Length","option2":null,"option3":null,"sku":"FLU-1551A-9","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1551A RTD Stik Thermometer \u0026 Temperature Calibrator - 1551A-9 : 9\" Length","public_title":"1551A-9 : 9\" Length","options":["1551A-9 : 9\" Length"],"price":124168,"weight":2268,"compare_at_price":116300,"inventory_management":"shopify","barcode":"095969546256","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16825570689067,"title":"1551A-20 : 20\" Length","option1":"1551A-20 : 20\" Length","option2":null,"option3":null,"sku":"FLU-1551A-20","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1551A RTD Stik Thermometer \u0026 Temperature Calibrator - 1551A-20 : 20\" Length","public_title":"1551A-20 : 20\" Length","options":["1551A-20 : 20\" Length"],"price":139672,"weight":2268,"compare_at_price":122700,"inventory_management":"shopify","barcode":"095969583909","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1551A_Pic_1.jpg?v=1564498796","\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1551A_Pic_2.jpg?v=1564498797"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1551A_Pic_1.jpg?v=1564498796","options":["Model"],"media":[{"alt":null,"id":2811563999275,"position":1,"preview_image":{"aspect_ratio":1.5,"height":410,"width":615,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1551A_Pic_1.jpg?v=1564498796"},"aspect_ratio":1.5,"height":410,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1551A_Pic_1.jpg?v=1564498796","width":615},{"alt":null,"id":2811564032043,"position":2,"preview_image":{"aspect_ratio":1.5,"height":1000,"width":1500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1551A_Pic_2.jpg?v=1564498797"},"aspect_ratio":1.5,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke_1551A_Pic_2.jpg?v=1564498797","width":1500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eIntrinsically-safe, battery operated, portable reference thermometer designed to go where you work; whether working outdoors in environments where potentially explosive gases may be present or on the floor of a processing plant. Available in 9\", 12\", or 20\" lengths with optional datalogging.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically safe (ATEX and IECEx compliant)\u003c\/li\u003e\n\u003cli\u003eStainless steel probe and digital readout are fixed together and calibrated as a system\u003c\/li\u003e\n\u003cli\u003eAccuracy of ±0.05°C (±0.09°F) over full range\u003c\/li\u003e\n\u003cli\u003eLarge backlit LCD display rotates 90° making it easy to read from any angle\u003c\/li\u003e\n\u003cli\u003eUser-configurable temperature trend\/stability indicator lets you know when your temperature is stable enough to record an accurate measurement\u003c\/li\u003e\n\u003cli\u003eDisplay temperature in °C or °F\u003c\/li\u003e\n\u003cli\u003eUser-selectable resolution (0.1, 0.01, 0.001)\u003c\/li\u003e\n\u003cli\u003eMax\/Min\/Trend\/Up key allows you to see the maximum or minimum temperature since the most recent power up\u003c\/li\u003e\n\u003cli\u003eSimple three-point calibration function allows you to easily and accurately calibrate the thermometer\u003c\/li\u003e\n\u003cli\u003eRequires a minimum immersion depth of only 7cm (2.8\"), with no appreciable effect on the measured temperature due to heat loss through stem conduction\u003c\/li\u003e\n\u003cli\u003eData logging to internal memory of up to 10,000 time-stamped measurements is optionally available\u003c\/li\u003e\n\u003cli\u003e300-hour battery life\u003c\/li\u003e\n\u003cli\u003ePercent battery-life and low-battery indicator\u003c\/li\u003e\n\u003cli\u003eNVLAP-accredited, NIST-traceable calibration included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e-50°C to 160°C\u003cbr\u003e(-58°F to 320°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (1 year)\u003c\/td\u003e\n\u003ctd\u003e±0.05°C (±0.09°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay units\u003c\/td\u003e\n\u003ctd\u003e°C, °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor type\u003c\/td\u003e\n\u003ctd\u003e100 Ω thin-film RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe temperature coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00385 Ω\/Ω\/°C nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor length\u003c\/td\u003e\n\u003ctd\u003e≤ 10 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor position (from sheath tip)\u003c\/td\u003e\n\u003ctd\u003e3 mm (0.1 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum immersion depth\u003c\/td\u003e\n\u003ctd\u003e7 cm (2.8 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe sheath material\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e4.8 mm diameter probe (3\/16 in): 14 seconds\u003cbr\u003e6.35 mm diameter probe (1\/4 in): 21 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe hysteresis\u003c\/td\u003e\n\u003ctd\u003e±0.01°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature resolution\u003c\/td\u003e\n\u003ctd\u003eSelectable: 0.1, 0.01, 0.001 (default 0.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFluke 1551A RTD Stik Thermometer (9\", 12\" or 20\" Length)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1551A.PDF?1804\" target=\"_blank\" title=\"Fluke 1551A Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1551A Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 1551A RTD Stik Thermometer & Temperature Calibrator

Fluke 1551A RTD Stik Thermometer & Temperature Calibrator

$1,396.72 CAD

Intrinsically-safe, battery operated, portable reference thermometer designed to go where you work; whether working outdoors in environments where potentially explosive gases may be present or on the floor of a processing plant. Available in 9", 12", or 20" lengths with optional datalogging. Overview Intrinsically safe (ATEX and IECEx complian...


More Info
Fluke 1555 10kV Digital Insulation Tester

Insulation Testers

From $9,616.55 CAD
{"id":1069130022955,"title":"Fluke 1555 10kV Digital Insulation Tester","handle":"fluke-1555-10kv-insulation-resistance-tester","description":"\u003cp\u003e\u003cspan\u003eEvaluate the trends and eliminate the doubt with this insulation resistance tester. Ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables, the CAT III 1000 V\/CAT IV 600 V safety-rated tester can conduct digital insulation testing up to 10 kV. By adding this to your preventive or predictive maintenance programs, it can help to identify potential equipment failures before they occur.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest voltages to up 10 kV and save time by trending on the spot only with Fluke Connect™\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage (DC)\u003c\/td\u003e\n\u003ctd\u003eRange (DC)\u003c\/td\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e250 kΩ to 5 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 GΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 50 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e500 kΩ to 10 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 GΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 100 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e1 MΩ to 20 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20 GΩ to 200 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 200 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e50 GΩ to 500 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 500 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 MΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e100 GΩ to 1 TΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 1 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 MΩ to 200 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 GΩ to 2 TΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 2 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLeakage Current Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 nA to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (5 % + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCapacitance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 uF to 15.00°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (15 % rdg + 0.03°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eTimer\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 99 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eResolution Setting: 1 minute Indication: 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModel 1555\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eTest Cables with Alligator Clips\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC Power Cord\u003c\/li\u003e\n\u003cli\u003eUsers Manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Installation Guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR Cable Installation Guide\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel 1555\/KIT\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eTest cables with alligator clips (red, black, green)\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC power cord\u003c\/li\u003e\n\u003cli\u003eUser's manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms installation guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR cable installation guide\u003c\/li\u003e\n\u003cli\u003eHeavy duty alligator clip leads\u003c\/li\u003e\n\u003cli\u003eHard Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel 1555FC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eIR3000FC1550 Connector\u003c\/li\u003e\n\u003cli\u003eTest Cables with Alligator Clips\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC Power Cord\u003c\/li\u003e\n\u003cli\u003eUsers Manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Installation Guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR Cable Installation Guide\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1550-1555_Spec.pdf?1595\" target=\"_blank\" title=\"Fluke 1555 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1555 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-03-05T15:57:38-07:00","created_at":"2018-03-05T16:00:01-07:00","vendor":"Fluke","type":"Insulation Testers","tags":[],"price":961655,"price_min":961655,"price_max":1065151,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11001299370027,"title":"1555","option1":"1555","option2":null,"option3":null,"sku":"FLU-1555","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1555 10kV Digital Insulation Tester - 1555","public_title":"1555","options":["1555"],"price":961655,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969550925","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16793619922987,"title":"1555\/KIT","option1":"1555\/KIT","option2":null,"option3":null,"sku":"FLU-1555\/KIT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1555 10kV Digital Insulation Tester - 1555\/KIT","public_title":"1555\/KIT","options":["1555\/KIT"],"price":1065151,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969550970","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":16793619955755,"title":"1555 FC","option1":"1555 FC","option2":null,"option3":null,"sku":"FLU-1555FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1555 10kV Digital Insulation Tester - 1555 FC","public_title":"1555 FC","options":["1555 FC"],"price":961655,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969868891","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1555-f5d-1.jpg?v=1520290804"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1555-f5d-1.jpg?v=1520290804","options":["Model"],"media":[{"alt":null,"id":1469096853547,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1555-f5d-1.jpg?v=1520290804"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1555-f5d-1.jpg?v=1520290804","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eEvaluate the trends and eliminate the doubt with this insulation resistance tester. Ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables, the CAT III 1000 V\/CAT IV 600 V safety-rated tester can conduct digital insulation testing up to 10 kV. By adding this to your preventive or predictive maintenance programs, it can help to identify potential equipment failures before they occur.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTest voltages to up 10 kV and save time by trending on the spot only with Fluke Connect™\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V, CAT IV 600 V safety rating\u003c\/li\u003e\n\u003cli\u003eWarning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety\u003c\/li\u003e\n\u003cli\u003eSelectable test voltages in 50 V steps from 250 V to 1000 V, and 100 V steps above 1000 V\u003c\/li\u003e\n\u003cli\u003eMeasurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall\u003c\/li\u003e\n\u003cli\u003eLong battery life gives the user over 750 tests between charges\u003c\/li\u003e\n\u003cli\u003eAutomatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup\u003c\/li\u003e\n\u003cli\u003eGuard system eliminates the effect of surface leakage current on high-resistance measurements\u003c\/li\u003e\n\u003cli\u003eLarge digital\/analog LCD for easy viewing\u003c\/li\u003e\n\u003cli\u003eCapacitance and leakage current measurement\u003c\/li\u003e\n\u003cli\u003eRamp function for breakdown testing\u003c\/li\u003e\n\u003cli\u003eResistance measurements up to 2 TΩ\u003c\/li\u003e\n\u003cli\u003eTimer settings up to 99 minutes for timed tests\u003c\/li\u003e\n\u003cli\u003e3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage (DC)\u003c\/td\u003e\n\u003ctd\u003eRange (DC)\u003c\/td\u003e\n\u003ctd\u003eAccuracy (± reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 250 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e250 kΩ to 5 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 GΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 50 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 kΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e500 kΩ to 10 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 GΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 100 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e1 MΩ to 20 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20 GΩ to 200 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 200 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2500 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2.5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e2.5 MΩ to 50 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e50 GΩ to 500 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 500 GΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5 MΩ to 100 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e100 GΩ to 1 TΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 1 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10000 V\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 MΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 MΩ to 200 GΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e10 GΩ to 2 TΩ\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e\u0026gt; 2 TΩ\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e5%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003e20%\u003cspan\u003e \u003c\/span\u003e\u003cbr\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLeakage Current Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 nA to 2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (5 % + 2 nA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCapacitance Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.01 uF to 15.00°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± (15 % rdg + 0.03°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eTimer\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 to 99 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eResolution Setting: 1 minute Indication: 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModel 1555\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eTest Cables with Alligator Clips\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC Power Cord\u003c\/li\u003e\n\u003cli\u003eUsers Manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Installation Guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR Cable Installation Guide\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel 1555\/KIT\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eTest cables with alligator clips (red, black, green)\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC power cord\u003c\/li\u003e\n\u003cli\u003eUser's manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms installation guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR cable installation guide\u003c\/li\u003e\n\u003cli\u003eHeavy duty alligator clip leads\u003c\/li\u003e\n\u003cli\u003eHard Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eModel 1555FC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation Resistance Tester\u003c\/li\u003e\n\u003cli\u003eIR3000FC1550 Connector\u003c\/li\u003e\n\u003cli\u003eTest Cables with Alligator Clips\u003c\/li\u003e\n\u003cli\u003eInfrared adapter with interface cable\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Basic CD-ROM\u003c\/li\u003e\n\u003cli\u003eAC Power Cord\u003c\/li\u003e\n\u003cli\u003eUsers Manual on CD-ROM\u003c\/li\u003e\n\u003cli\u003eFlukeView® Forms Installation Guide\u003c\/li\u003e\n\u003cli\u003eUSB-IR Cable Installation Guide\u003c\/li\u003e\n\u003cli\u003eSoft Carrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1550-1555_Spec.pdf?1595\" target=\"_blank\" title=\"Fluke 1555 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1555 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 1555 10kV Digital Insulation Tester

Fluke 1555 10kV Digital Insulation Tester

$9,616.55 CAD

Evaluate the trends and eliminate the doubt with this insulation resistance tester. Ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables, the CAT III 1000 V/CAT IV 600 V safety-rated tester can conduct digital insulation testing up to 10 kV. By adding this to your preventive or predictive m...


More Info
{"id":1122433728555,"title":"Fluke 1577 Insulation Multimeter *** SEE FLUKE 1587FC***","handle":"fluke-1577-insulation-multimeter","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe Fluke 1577 Insulation Multimeter combine a \u003c\/span\u003e\u003ca title=\"Insulation Resistance Testers\" href=\"http:\/\/en-us.fluke.com\/products\/insulation-testers\/fluke-1555-electrical-tester.html\"\u003edigital insulation tester\u003c\/a\u003e\u003cspan\u003e with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.\u003c\/span\u003e","published_at":"2018-03-23T16:57:27-06:00","created_at":"2018-03-23T17:00:57-06:00","vendor":"Fluke","type":"Insulation Testers","tags":[],"price":132327,"price_min":132327,"price_max":132327,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11328867336235,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-1577","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1577 Insulation Multimeter *** SEE FLUKE 1587FC***","public_title":null,"options":["Default Title"],"price":132327,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969262965","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1577.jpg?v=1521846059"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1577.jpg?v=1521846059","options":["Title"],"media":[{"alt":null,"id":1517856030763,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1577.jpg?v=1521846059"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1577.jpg?v=1521846059","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eThe Fluke 1577 Insulation Multimeter combine a \u003c\/span\u003e\u003ca title=\"Insulation Resistance Testers\" href=\"http:\/\/en-us.fluke.com\/products\/insulation-testers\/fluke-1555-electrical-tester.html\"\u003edigital insulation tester\u003c\/a\u003e\u003cspan\u003e with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.\u003c\/span\u003e"}
Fluke 1577 Insulation Multimeter *** SEE FLUKE 1587FC***

Fluke 1577 Insulation Multimeter *** SEE FLUKE 1587FC***

$1,323.27 CAD

The Fluke 1577 Insulation Multimeter combine a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.


More Info
{"id":1072453517355,"title":"Fluke 1587\/MDT FC Advanced Motor and Drive Troubleshooting Kit","handle":"fluke-1587-mdt-advanced-motor-drive-troubleshooting-kit","description":"\u003cp\u003e\u003cstrong\u003eThe Fluke 1587 FC Insulation Multimeter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures four powerful new diagnostic functions through the Fluke Connect Measurements app:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePl\/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster\u003c\/li\u003e\n\u003cli\u003eMemory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time\u003c\/li\u003e\n\u003cli\u003eTemperature Compensation through app for establishing accurate baselines and relevant historical comparisons\u003c\/li\u003e\n\u003cli\u003eHistorical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke i400 AC Current Clamp\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-safety current clamp for digital multimeters. The current clamp provides accurate current measurements without breaking electric circuits, helping you take measurements safely with industry standard safety ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 9040 Phase Rotation Indicator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis effective for measuring phase rotation in all areas where three phase supplies are used to feed motors, drives and electrical systems. It allows rapid determination of phase sequence and ideally suited for commercial and industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes a Fluke 1587 FC 2-in-1 Insulation DMM, Fluke i400 Current Clamp, and a Fluke 9040 Phase Rotation Indicator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWith the Fluke 1587 FC, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease\u003c\/li\u003e\n\u003cli\u003eUse the Fluke i400 with your Fluke 1587 FC to accurately measure AC current without breaking the circuit\u003c\/li\u003e\n\u003cli\u003eCheck the rotation of three-phase motors easily and safely with the Fluke 9040\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke 1587 FC 2-in-1 Insulation DMM\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePl\/DAR measurements with TrendIt™ graphs\u003c\/li\u003e\n\u003cli\u003eMemory storage through Fluke Connect Measurements app\u003c\/li\u003e\n\u003cli\u003eTemperature Compensation through Fluke Connect Measurements app\u003c\/li\u003e\n\u003cli\u003eVFD low-pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eInsulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/li\u003e\n\u003cli\u003eInsulation test voltages 500 V, 1000 V\u003c\/li\u003e\n\u003cli\u003eInsulation test: 0.01 MΩ to 2.0 GΩ\u003c\/li\u003e\n\u003cli\u003eInsulation test: 0.1 MΩ to 600 MΩ\u003c\/li\u003e\n\u003cli\u003eAuto-discharge of capacitive voltage\u003c\/li\u003e\n\u003cli\u003eInsulation test smoothing reading\u003c\/li\u003e\n\u003cli\u003eFrequency \/ Capacitance \/ Diode test \/ Temperature\u003c\/li\u003e\n\u003cli\u003eMin\/Max \/ AC\/DC Voltage \/ DC Millivolts \/ AC\/DC Milliamps\u003c\/li\u003e\n\u003cli\u003eResistance (0.1 Ω to 50 MΩ) \/ Continuity \/ Auto power off\u003c\/li\u003e\n\u003cli\u003eThree-year warranty \/ Remote probe, test leads, alligator clips, K-type thermocouple, hard case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke i400 AC Current Clamp\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse with your Fluke 1587 FC to measure 1A AC to 400 A AC\u003c\/li\u003e\n\u003cli\u003e1 mA\/Amp output guarantees easy reading\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V \/ CAT IV 600 V overvoltage rating for added user protection\u003c\/li\u003e\n\u003cli\u003eSpecially designed to offer maximum utility in a very compact shape\u003c\/li\u003e\n\u003cli\u003eMaximum conductor: Ø 32 mm\u003c\/li\u003e\n\u003cli\u003e1 year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 9040 Phase Rotation Indicator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLarge display to easily determine field rotation and phase sequence\u003c\/li\u003e\n\u003cli\u003eIndication for all three phases\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V overvoltage rating\u003c\/li\u003e\n\u003cli\u003e2 year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1587 FC Insulation Multimeter\u003c\/li\u003e\n\u003cli\u003ei400 Current Clamp\u003c\/li\u003e\n\u003cli\u003e9040 Phase Rotation Indicator\u003c\/li\u003e\n\u003cli\u003eRemote Probe\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003cli\u003eAlligator Clips\u003c\/li\u003e\n\u003cli\u003eK-Type Thermocouple\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003cli\u003eUser Documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1587FC.pdf?1805\" target=\"_blank\" title=\"Fluke 1587FC Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1587FC Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2018-03-06T16:07:50-07:00","created_at":"2018-03-06T16:10:32-07:00","vendor":"Fluke","type":"Insulation Testers","tags":[],"price":213383,"price_min":213383,"price_max":213383,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11020100436011,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-1587FC\/MDT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1587\/MDT FC Advanced Motor and Drive Troubleshooting Kit","public_title":null,"options":["Default Title"],"price":213383,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"095969797283","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/91tKJQ_eusL._SL1500.jpg?v=1520377834","\/\/kingswayinstruments.com\/cdn\/shop\/products\/2PY96_AS01.jpg?v=1520377835"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/91tKJQ_eusL._SL1500.jpg?v=1520377834","options":["Title"],"media":[{"alt":null,"id":1472794099755,"position":1,"preview_image":{"aspect_ratio":1.272,"height":1179,"width":1500,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/91tKJQ_eusL._SL1500.jpg?v=1520377834"},"aspect_ratio":1.272,"height":1179,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/91tKJQ_eusL._SL1500.jpg?v=1520377834","width":1500},{"alt":null,"id":1472794132523,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/2PY96_AS01.jpg?v=1520377835"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/2PY96_AS01.jpg?v=1520377835","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cstrong\u003eThe Fluke 1587 FC Insulation Multimeter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures four powerful new diagnostic functions through the Fluke Connect Measurements app:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePl\/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster\u003c\/li\u003e\n\u003cli\u003eMemory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time\u003c\/li\u003e\n\u003cli\u003eTemperature Compensation through app for establishing accurate baselines and relevant historical comparisons\u003c\/li\u003e\n\u003cli\u003eHistorical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke i400 AC Current Clamp\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-safety current clamp for digital multimeters. The current clamp provides accurate current measurements without breaking electric circuits, helping you take measurements safely with industry standard safety ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 9040 Phase Rotation Indicator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis effective for measuring phase rotation in all areas where three phase supplies are used to feed motors, drives and electrical systems. It allows rapid determination of phase sequence and ideally suited for commercial and industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes a Fluke 1587 FC 2-in-1 Insulation DMM, Fluke i400 Current Clamp, and a Fluke 9040 Phase Rotation Indicator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWith the Fluke 1587 FC, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease\u003c\/li\u003e\n\u003cli\u003eUse the Fluke i400 with your Fluke 1587 FC to accurately measure AC current without breaking the circuit\u003c\/li\u003e\n\u003cli\u003eCheck the rotation of three-phase motors easily and safely with the Fluke 9040\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe Fluke 1587 FC 2-in-1 Insulation DMM\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePl\/DAR measurements with TrendIt™ graphs\u003c\/li\u003e\n\u003cli\u003eMemory storage through Fluke Connect Measurements app\u003c\/li\u003e\n\u003cli\u003eTemperature Compensation through Fluke Connect Measurements app\u003c\/li\u003e\n\u003cli\u003eVFD low-pass filter for accurate motor drive measurements\u003c\/li\u003e\n\u003cli\u003eInsulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V\u003c\/li\u003e\n\u003cli\u003eInsulation test voltages 500 V, 1000 V\u003c\/li\u003e\n\u003cli\u003eInsulation test: 0.01 MΩ to 2.0 GΩ\u003c\/li\u003e\n\u003cli\u003eInsulation test: 0.1 MΩ to 600 MΩ\u003c\/li\u003e\n\u003cli\u003eAuto-discharge of capacitive voltage\u003c\/li\u003e\n\u003cli\u003eInsulation test smoothing reading\u003c\/li\u003e\n\u003cli\u003eFrequency \/ Capacitance \/ Diode test \/ Temperature\u003c\/li\u003e\n\u003cli\u003eMin\/Max \/ AC\/DC Voltage \/ DC Millivolts \/ AC\/DC Milliamps\u003c\/li\u003e\n\u003cli\u003eResistance (0.1 Ω to 50 MΩ) \/ Continuity \/ Auto power off\u003c\/li\u003e\n\u003cli\u003eThree-year warranty \/ Remote probe, test leads, alligator clips, K-type thermocouple, hard case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke i400 AC Current Clamp\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse with your Fluke 1587 FC to measure 1A AC to 400 A AC\u003c\/li\u003e\n\u003cli\u003e1 mA\/Amp output guarantees easy reading\u003c\/li\u003e\n\u003cli\u003eCAT III 1000 V \/ CAT IV 600 V overvoltage rating for added user protection\u003c\/li\u003e\n\u003cli\u003eSpecially designed to offer maximum utility in a very compact shape\u003c\/li\u003e\n\u003cli\u003eMaximum conductor: Ø 32 mm\u003c\/li\u003e\n\u003cli\u003e1 year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFluke 9040 Phase Rotation Indicator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLarge display to easily determine field rotation and phase sequence\u003c\/li\u003e\n\u003cli\u003eIndication for all three phases\u003c\/li\u003e\n\u003cli\u003eCAT III 600 V overvoltage rating\u003c\/li\u003e\n\u003cli\u003e2 year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ch4\u003e\u003c\/h4\u003e\n\u003cspan\u003eSee Resources for Product Data Sheet\u003c\/span\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1587 FC Insulation Multimeter\u003c\/li\u003e\n\u003cli\u003ei400 Current Clamp\u003c\/li\u003e\n\u003cli\u003e9040 Phase Rotation Indicator\u003c\/li\u003e\n\u003cli\u003eRemote Probe\u003c\/li\u003e\n\u003cli\u003eTest Leads\u003c\/li\u003e\n\u003cli\u003eAlligator Clips\u003c\/li\u003e\n\u003cli\u003eK-Type Thermocouple\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003cli\u003eUser Documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1587FC.pdf?1805\" target=\"_blank\" title=\"Fluke 1587FC Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1587FC Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e"}
Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit

Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit

$2,133.83 CAD

The Fluke 1587 FC Insulation Multimeter features four powerful new diagnostic functions through the Fluke Connect Measurements app: Pl/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for ...


More Info