AEMC 403 True RMS Clamp Meter with Temperature, 1000A AC/1500A DC
Product Description
The True RMS Clamp-On Meter Model 403 is safety rated at 1000V CAT IV. It measures voltage, current, resistance, frequency, True InRush®, temperature, and continuity. It can also perform diode checks. Adapter mode allows external sensor inputs to be displayed. Delta relative function allows new measurements to be compared to a reference value. This rugged meter can operate in demanding work environments, and its IP54 rating allows it to withstand both dust and water spray.
Overview
- 1000V CAT IV Rated
 - UL 94 flame retardant self-extinguishing
 - IP54 Rated
 - 10,000-count blue electroluminescent backlit display
 - Measures up to 1000VAC (1400V peak), 1000VDC and AC and DC with resolution to 10mV
 - Measures up to 1000AAC and 2000ADC
 - Measures temperature in °F or °C using a K-type Thermocouple
 - Measures frequency to 20kHz with 0.1Hz resolution
 - Auto selects AC or DC measurement voltage
 - True InRush® current measurement with 1mS capture
 - Delta relative function for tracking deviation from reference values
 - Adapter function to accept inputs from sensors and transducers with a millivolt output with user programmable scaling
 - Jaw opening up to 1.89"
 - Leads are constructed with a flexible silicone material
 
Specifications
| Voltage Range: | 1000Vrms AC/DC Autoranging | 
| Resolution Max: | 0.01V | 
| Current Range: | 1000Arms AC, 1500ADC | 
| Resolution Max: | 0.01A | 
| Accuracy V Typical: | 1% ± 3cts | 
| Accuracy A Typical: | 1% ± 3cts | 
| InRush: | 10 to 1000A | 
| Continuity: | Selectable from 0 to 999.9Ω | 
| Resistance: | 100kΩ | 
| Diode Test: | 0 to 3.2VDC | 
| Frequency: | 20kHz in V, 2kHz in A | 
| Temperature K Thermocouple: | -76.0 to 2192°F (-60 to 1200°C) | 
| Adapter Function: | Yes | 
| LCD w/backlight: | Yes | 
| MIN/MAX: | Yes | 
| Power Source: | 4 x AA, NEDA 15A, IEC LR6 | 
| Battery Life: | >350 hours | 
| Dimensions: | 10.7 x 3.6 x 1.6" (272 x 92 x 41mm) | 
| Weight: | 1.32 lbs (600g) with batteries | 
| Jaw Opening: | 1.89" (48mm) | 
| Operating Temperature: | -4° to +131°F (-20° to +55°C) | 
| Storage Temperature: | -40° to +158°F (-40° to +70°C) | 
| Operating Humidity: | 90% up to 131°F (55°C) | 
| Pollution Degree: | 2 | 
| Ingress Protection: | IP54 | 
| EMC: | EN61326-1 | 
| Safety Compliance: | EN/IEC 61010-1 to 1000V CAT IV![]() EN/IEC 61010-2-030:2010 EN/IEC 61010-032:2002  | 
 
							
What's in the Box
- True RMS Clamp-on Meter
 - 2152.03 Silicone Lead Set, 1000V, CAT IV Rated
 - 2139.71 Type K Thermocouple
 - 2139.72 Soft Carrying Case
 - 4 x AA 1.2V Batteries
 - Manual
 

          