AEMC ML912 Simple Logger II AC Current Data Logger, 100/1000 A
Product Description
The Simple Logger ® II Model ML912 is a two channel AC current recording device powered by two alkaline batteries. It incorporates two user selectable measurement ranges of 0 to 100 Amps and 0 to 1000 Amps. Line tracking is performed such that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency 50 or 60Hz. Harmonic measurements are calculated from these 64 samples. Harmonics are only available from the Simple Logger ® II Control Panel within the free DataView® software included with the unit.
Two channel AC recording logger includes two integral MiniFlex flexible current probes that measure from 0.5A to 1000A TRMS. Stores up to 240,000 measurements.
Overview
- Includes two integral MiniFlex® flexible current probes that will measure from 0.5A to 1000A TRMS with 0.1A resolution
- Dual range 100/1000A user selectable per channel
- 64 samples per cycle
- Programmable storage rates from 8 every second to 1 every day
- 4 user selectable storage modes
- Stores up to 240,000 measurements in non-volatile memory
- Powered by standard Alkaline batteries
- Lightweight, compact, fits anywhere
- 5 LED indicators quickly and clearly display logger status
- Includes FREE DataView® software for data storage, real-time display, analysis and report generation
- Isolated USB 2.0 communication cable included
- EN 61010-1; 600V CAT IV, 1000V CAT III
Specifications
Channels | Two |
Input | Captive MiniFlex® AC Current Flexible Sensors |
Range and Accuracy | 0.5 to 100A AC: 0 to 1A unspecified 1 to 100A: ±(1% of Reading + 0.5A 5 to 1000A AC: 0 to 5A unspecified 5 to 1000A: ±(1% of Reading + 1A) |
Resolution | 0.1A |
Sample Rate | 64 samples/cycle |
Storage Rate | Programmable from 8 every second to 1 every day |
Storage Modes | Start/Stop, FIFO, Extended Recording Mode (XRM™) and Alarm |
Recording Length | 15 minutes to 8 weeks, programmable using DataView® |
Memory | 240,000 measurement (512KB) Data is stored in non-volatile memory and retained if the battery is low or removed |
Communication | USB 2.0 optically isolated |
What's in the Box
- ML912 Simple Logger II
- USB cable
- DataView® software
- 2 x 1.5V AA alkaline batteries
- Manual