{ "id":6180023238846, "title":"AEMC 6418 Ground Resistance Tester","handle":"aemc-6418-ground-resistance-tester", "description":"\u003cp\u003e\u003cspan\u003eThe Ground Resistance Tester Model 6418 measures ground rod, busbar, and grid resistance and impedance without the use of auxiliary rods. Clamp-on ground resistance testers can be used in multi-grounded systems without disconnecting or de-energizing the ground system under test. The Model 6418 simply clamps around the grounding electrode or conductor and measures the resistance to ground. By performing measurements on intact ground systems, the user also verifies the quality of the grounding connections and bonds. Resistance and continuity of grounding loops around pads and buildings may also be measured.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLoop resistance measurement from 0.01 to 1200 Ω\u003c\/li\u003e\n\u003cli\u003eCurrent measurement from 0.5 mA to 20 A\u003c\/li\u003e\n\u003cli\u003eAlarms available in Ω and A\u003c\/li\u003e\n\u003cli\u003eTime\/date-stamped storage of 300 measurements\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration of the jaw gap\u003c\/li\u003e\n\u003cli\u003eRecalibration possible without returning to factory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eLoop Ohmmeter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Ranges\u003c\/td\u003e\n\u003ctd\u003e0.010 to 0.099 Ω\u003cbr\u003e0.10 to 0.99 Ω\u003cbr\u003e1 to 49.9 Ω\u003cbr\u003e50 to 149 Ω\u003cbr\u003e150 to 245 Ω\u003cbr\u003e250 to 440 Ω\u003cbr\u003e450 to 640 Ω\u003cbr\u003e650 to 1200 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 mΩ\u003cbr\u003e10 mΩ\u003cbr\u003e100 mΩ\u003cbr\u003e1 Ω\u003cbr\u003e5 Ω\u003cbr\u003e10 Ω\u003cbr\u003e50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(1.5% R + 0.01 Ω)\u003cbr\u003e±(1.5% R + 2 r\u003cbr\u003e±(2.5% R + 2 r)\u003cbr\u003e±(5% R + 2 r)\u003cbr\u003e±(10% R + 2 r)\u003cbr\u003e±(15% R + 2 r)\u003cbr\u003e±(20% R + 2 r)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo-Load Voltage\u003c\/td\u003e\n\u003ctd\u003e≤4.5 mV to 2083 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eAnmeter\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Ranges\u003c\/td\u003e\n\u003ctd\u003e0.5 to 9.995 mA\u003cbr\u003e10.00 to 99.90 mA\u003cbr\u003e100.0 to 299.0 mA\u003cbr\u003e0.300 to 2.990 A\u003cbr\u003e3.00 to 20.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e50 μA\u003cbr\u003e100 μA\u003cbr\u003e1 mA\u003cbr\u003e10 mA\u003cbr\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% R + 200 μA)\u003cbr\u003e±(2% R + r)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eSetup\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarms\u003c\/td\u003e\n\u003ctd\u003eConfigurable for Z and I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuzzer\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHOLD\u003c\/td\u003e\n\u003ctd\u003eManual or automatic PRE-Hold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Power-Off\u003c\/td\u003e\n\u003ctd\u003eActive\/Inactive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e4 x 1.5 V LR6 AA alkaline batteries or 4 x NiMH batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEC 61010\u003c\/td\u003e\n\u003ctd\u003e100 V CAT IV , 150 V CAT III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11.8 x 4.17 x 2.2\" (300 x 106 x 56 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.65 lbs (1.2 kg) approx. including batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGround Resistance Tester\u003c\/li\u003e\n\u003cli\u003eVerification Certificate\u003c\/li\u003e\n\u003cli\u003eWrist Strap\u003c\/li\u003e\n\u003cli\u003eCD Containing the Operating Manuals\u003c\/li\u003e\n\u003cli\u003eMultilingual Safety Datasheet\u003c\/li\u003e\n\u003cli\u003eMultilingual Quick Start Guide\u003c\/li\u003e\n\u003cli\u003e4 x Batteries\u003c\/li\u003e\n\u003cli\u003eCarrying Case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_6418-2141-03.pdf?v=1611007174\" target=\"_blank\" title=\"AEMC 6418 Ground Resistance Tester Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 6418 Ground Resistance Tester Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2021-01-18T15:32:29", "created_at":"2021-01-18T15:32:28", "vendor":"AEMC Instruments", "type":"Earth Ground Testers", "tags":[], "price":249200, "price_min":249200, "price_max":249200, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[37913019941054], "variants":[{ "id":37913019941054, "product_id":6180023238846, "product_handle":"aemc-6418-ground-resistance-tester", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"AEMC-2141.03", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"AEMC 6418 Ground Resistance Tester - Default Title", "options":["Default Title"], "price":249200, "weight":4082, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"685338130591"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6418Pic1.jpg?v=1611009149"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC6418Pic1.jpg?v=1611009149", "options":["Title"], "url":"\/products\/aemc-6418-ground-resistance-tester"}

AEMC 6418 Ground Resistance Tester

Product Description

The Ground Resistance Tester Model 6418 measures ground rod, busbar, and grid resistance and impedance without the use of auxiliary rods. Clamp-on ground resistance testers can be used in multi-grounded systems without disconnecting or de-energizing the ground system under test. The Model 6418 simply clamps around the grounding electrode or conductor and measures the resistance to ground. By performing measurements on intact ground systems, the user also verifies the quality of the grounding connections and bonds. Resistance and continuity of grounding loops around pads and buildings may also be measured.

Sku: AEMC-2141.03
On Back-Order
$2,492.00 CAD

  • Loop resistance measurement from 0.01 to 1200 Ω
  • Current measurement from 0.5 mA to 20 A
  • Alarms available in Ω and A
  • Time/date-stamped storage of 300 measurements
  • Automatic calibration of the jaw gap
  • Recalibration possible without returning to factory
Loop Ohmmeter
Measurement Ranges 0.010 to 0.099 Ω
0.10 to 0.99 Ω
1 to 49.9 Ω
50 to 149 Ω
150 to 245 Ω
250 to 440 Ω
450 to 640 Ω
650 to 1200 Ω
Resolution 1 mΩ
10 mΩ
100 mΩ
1 Ω
5 Ω
10 Ω
50 Ω
Accuracy ±(1.5% R + 0.01 Ω)
±(1.5% R + 2 r
±(2.5% R + 2 r)
±(5% R + 2 r)
±(10% R + 2 r)
±(15% R + 2 r)
±(20% R + 2 r)
No-Load Voltage ≤4.5 mV to 2083 Hz
Anmeter
Measurement Ranges 0.5 to 9.995 mA
10.00 to 99.90 mA
100.0 to 299.0 mA
0.300 to 2.990 A
3.00 to 20.00 A
Resolution 50 μA
100 μA
1 mA
10 mA
100 mA
Accuracy ±(2% R + 200 μA)
±(2% R + r)
Setup
Alarms Configurable for Z and I
Buzzer Active
HOLD Manual or automatic PRE-Hold
Automatic Power-Off Active/Inactive
General Specifications
Power Supply 4 x 1.5 V LR6 AA alkaline batteries or 4 x NiMH batteries
IEC 61010 100 V CAT IV , 150 V CAT III
Ingress Protection IP 40
Dimensions 11.8 x 4.17 x 2.2" (300 x 106 x 56 mm)
Weight 2.65 lbs (1.2 kg) approx. including batteries


  • Ground Resistance Tester
  • Verification Certificate
  • Wrist Strap
  • CD Containing the Operating Manuals
  • Multilingual Safety Datasheet
  • Multilingual Quick Start Guide
  • 4 x Batteries
  • Carrying Case