Earth Ground Testers

Megger DET3 Series 3-Terminal Digital Ground Tester

Earth Ground Testers

From $1,080.00 CAD
{"id":1843152420907,"title":"Megger DET3 Series 3-Terminal Digital Ground Tester","handle":"megger-det3tc-3-terminal-digital-ground-tester","description":"\u003cp\u003eThe DET3TD is for basic ground testing while the DET3TC includes a current measuring function for ART (Attached Rod Technique) testing capabilities. With this added function, on-site grounds can be tested separately without having to remove the utility connection (as explained further in this document).\u003c\/p\u003e\n\u003cp\u003eBy using the optional ICLAMP with the DET3TC, the user can augment the traditional fall-of-potential measurement method with ART (Attached Rod Technique), which allows electrode testing without disconnection and also leakage current measurements down to 0.5 mA.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIP54 rated\u003c\/li\u003e\n\u003cli\u003e2 and 3 point testing\u003c\/li\u003e\n\u003cli\u003eSelectable 25 V or 50 V output\u003c\/li\u003e\n\u003cli\u003eComplete with lead and stake kit\u003c\/li\u003e\n\u003cli\u003eSimple one button operation\u003c\/li\u003e\n\u003cli\u003eHard carry case\u003c\/li\u003e\n\u003cli\u003eDelivered with calibration certificate\u003c\/li\u003e\n\u003cli\u003eAttached Rod Technique (ART)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"920\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDET3TC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDET3TD\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP54\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP54\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eC Spike Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eP Spike Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNoise Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNoise Rejection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e40 V pk to pk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e40 V pk to pk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e2-Wire Test\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e3-Wire Test\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNo Disconnect Testing (ART)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes, with optional ICLAMP\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEarth Current Range with ICLAMP\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.5 mA to 19.9 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eResistance Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.01 to 2000Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.01 to 2000Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eResistance Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2% ±3 digits\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2% ±3 digits\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEarth Voltage Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0 - 100 V a.c.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0 - 100 V a.c.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEarth Voltage Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2% ±2 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2% ±2 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLCD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLCD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8 off AA cells\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8 off AA cells\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-15 to +55ºC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-15 to +55ºC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40 to +70ºC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40 to +70ºC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEN61010-1 CAT IV 100 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEN61010-1 CAT IV 100 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e203 x 148 x 78 mm (8 x 5.7 x 3.2 inches)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e203 x 148 x 78 mm (8 x 5.7 x 3.2 inches)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e3-Terminal Digital Ground Tester\u003c\/li\u003e\n\u003cli\u003eHard Carry Case\u003c\/li\u003e\n\u003cli\u003eReplacement 3-Wire Lead Set (15m Red Wire, 10m Yellow Wire, 4m Green Wire)\u003c\/li\u003e\n\u003cli\u003e2 x Ground Test Stakes (200mm, 8mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_DET3_Earth_Tester_Spec.pdf?1684\" target=\"_blank\" title=\"Megger DET3TC\" rel=\"noopener noreferrer\"\u003eMegger DET3 Series Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-07-29T09:48:49-06:00","created_at":"2019-07-29T09:56:30-06:00","vendor":"Megger","type":"Earth Ground Testers","tags":[],"price":108000,"price_min":108000,"price_max":133000,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16821896085547,"title":"MEG-DET3TC","option1":"MEG-DET3TC","option2":null,"option3":null,"sku":"MEG-DET3TC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET3 Series 3-Terminal Digital Ground Tester - MEG-DET3TC","public_title":"MEG-DET3TC","options":["MEG-DET3TC"],"price":133000,"weight":1361,"compare_at_price":null,"inventory_management":"shopify","barcode":""},{"id":16822297100331,"title":"MEG-DET3TD","option1":"MEG-DET3TD","option2":null,"option3":null,"sku":"MEG-DET3TD","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET3 Series 3-Terminal Digital Ground Tester - MEG-DET3TD","public_title":"MEG-DET3TD","options":["MEG-DET3TD"],"price":108000,"weight":1361,"compare_at_price":null,"inventory_management":"shopify","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/megger-det3tc.jpg?v=1564415798"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/megger-det3tc.jpg?v=1564415798","options":["Model"],"content":"\u003cp\u003eThe DET3TD is for basic ground testing while the DET3TC includes a current measuring function for ART (Attached Rod Technique) testing capabilities. With this added function, on-site grounds can be tested separately without having to remove the utility connection (as explained further in this document).\u003c\/p\u003e\n\u003cp\u003eBy using the optional ICLAMP with the DET3TC, the user can augment the traditional fall-of-potential measurement method with ART (Attached Rod Technique), which allows electrode testing without disconnection and also leakage current measurements down to 0.5 mA.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIP54 rated\u003c\/li\u003e\n\u003cli\u003e2 and 3 point testing\u003c\/li\u003e\n\u003cli\u003eSelectable 25 V or 50 V output\u003c\/li\u003e\n\u003cli\u003eComplete with lead and stake kit\u003c\/li\u003e\n\u003cli\u003eSimple one button operation\u003c\/li\u003e\n\u003cli\u003eHard carry case\u003c\/li\u003e\n\u003cli\u003eDelivered with calibration certificate\u003c\/li\u003e\n\u003cli\u003eAttached Rod Technique (ART)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"920\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDET3TC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDET3TD\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP54\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIP54\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eC Spike Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eP Spike Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNoise Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAutomatic\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNoise Rejection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e40 V pk to pk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e40 V pk to pk\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e2-Wire Test\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003e3-Wire Test\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eNo Disconnect Testing (ART)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eYes, with optional ICLAMP\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEarth Current Range with ICLAMP\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.5 mA to 19.9 A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eResistance Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.01 to 2000Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.01 to 2000Ω\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eResistance Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2% ±3 digits\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2% ±3 digits\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEarth Voltage Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0 - 100 V a.c.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0 - 100 V a.c.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eEarth Voltage Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2% ±2 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e2% ±2 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLCD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLCD\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8 off AA cells\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e8 off AA cells\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-15 to +55ºC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-15 to +55ºC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40 to +70ºC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40 to +70ºC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEN61010-1 CAT IV 100 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eEN61010-1 CAT IV 100 V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e203 x 148 x 78 mm (8 x 5.7 x 3.2 inches)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e203 x 148 x 78 mm (8 x 5.7 x 3.2 inches)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e3-Terminal Digital Ground Tester\u003c\/li\u003e\n\u003cli\u003eHard Carry Case\u003c\/li\u003e\n\u003cli\u003eReplacement 3-Wire Lead Set (15m Red Wire, 10m Yellow Wire, 4m Green Wire)\u003c\/li\u003e\n\u003cli\u003e2 x Ground Test Stakes (200mm, 8mm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_DET3_Earth_Tester_Spec.pdf?1684\" target=\"_blank\" title=\"Megger DET3TC\" rel=\"noopener noreferrer\"\u003eMegger DET3 Series Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger DET3 Series 3-Terminal Digital Ground Tester

Megger DET3 Series 3-Terminal Digital Ground Tester

$1,080.00 CAD

The DET3TD is for basic ground testing while the DET3TC includes a current measuring function for ART (Attached Rod Technique) testing capabilities. With this added function, on-site grounds can be tested separately without having to remove the utility connection (as explained further in this document). By using the optional ICLAMP with the DET3...


More Info
Megger DET4 Series Earth Ground Testers

Earth Ground Testers

From $1,710.00 CAD
{"id":1840875864107,"title":"Megger DET4 Series Earth Ground Testers","handle":"megger-det4-series","description":"\u003cp\u003eMegger’s popular 4-terminal ground testing instrument family includes four basic models with different kit variants for each that include select accessories for greater testing flexibility.\u003c\/p\u003e\n\u003cp\u003eThe four basic units are: Model Description DET4TD2 Dry-cell battery powered basic 4-terminal tester DET4TR2 Rechargeable battery powered basic 4-terminal tester DET4TC2 Dry-cell battery powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity and attached rod technique and stakeless measurement capability DET4TCR2 Rechargeable battery powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity and attached rod technique and stakeless measurement capability\u003c\/p\u003e\n\u003cp\u003eThe top-end models (DET4TC2 and DET4TCR2) include a current measuring function for ART (Attached Rod Technique) testing capabilities. With this added function, on-site grounds can be tested separately without having to remove the utility connection (as explained further in this document). They also provide stakeless testing capability. This method allows the operator to use the instrument like a clamp-on ground tester in applications where that method is viable, while also being able to operate as a fall of potential tester if required.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eStakeless testing capability, which allows the operator to use the instrument like a clamp-on tester in applications where the method is viable\u003c\/li\u003e\n\u003cli\u003eAttached Rod Technique capability, which allows fall of potential testing without the need to disconnect the ground rod\u003c\/li\u003e\n\u003cli\u003eMultiple, user selectable test frequencies allow the operator to find the most effective frequency for making the measurement\u003c\/li\u003e\n\u003cli\u003e200,000 Ω measurement range provides the ability to measure the resistivity of any type of soil\u003c\/li\u003e\n\u003cli\u003eUser selectable test voltage ensures that the units can be used in agricultural environments\u003c\/li\u003e\n\u003cli\u003eMicroprocessor control for improved error detection\u003c\/li\u003e\n\u003cli\u003eClear, unambiguous warnings and error indications ensure the reliability of the reading and reduce test time\u003c\/li\u003e\n\u003cli\u003eRugged, weatherproof case to IP54 makes the units truly outdoor instruments\u003c\/li\u003e\n\u003cli\u003eBacklit LCD allows for testing in dark environments\u003c\/li\u003e\n\u003cli\u003eNoise rejection to 40 V pk to pk allows accurate testing in noisy environments\u003c\/li\u003e\n\u003cli\u003eTesting kits and certificates supplied — everything needed to start testing immediately\u003c\/li\u003e\n\u003cli\u003eAccuracy of 2% of reading enhances reliability of measurements\u003c\/li\u003e\n\u003cli\u003eVoltmeter function included allows you to measure the ground voltage and enhances operator safety\u003c\/li\u003e\n\u003cli\u003eCAT IV 100V provides increased operator safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"721\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"133\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eSelection Guide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"280\"\u003eModel #\u003c\/td\u003e\n\u003ctd width=\"77\"\u003eDET4TD2\u003c\/td\u003e\n\u003ctd width=\"77\"\u003eDET4TR2\u003c\/td\u003e\n\u003ctd width=\"77\"\u003eDET4TC2\u003c\/td\u003e\n\u003ctd width=\"77\"\u003eDET4TCR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"9\"\u003e\u003cspan\u003e\u003cstrong\u003eTests\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2-Pole Measurement\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3-Pole Measurement\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-Pole Measurement\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoil Resistivity\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eART Capability\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStakeless Measurement Capability\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e0.01 to 20,000 Ω \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e0.01 to 200,000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Voltage Range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003e0 to 100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Current Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e0.5 mA to 19.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable Voltage (25\/50 V)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Frequency\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e128 Hz\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e94, 105, 111, 128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlkaline Batteries\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRechargeable Batteries\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise Rejection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 V Peak-to-Peak\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT IV 100V\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRated to IP54\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHard Carry Case\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTest Leads (49 ft, 33 ft, 33 ft, 10 ft) and Spikes\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHard Carrying Case\u003c\/li\u003e\n\u003cli\u003e4 x Test Leads (49ft, 33ft, 33ft, 10ft)\u003c\/li\u003e\n\u003cli\u003eSet of Spikes\u003c\/li\u003e\n\u003cli\u003e8 x AA Alkaline Batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_DET4_Series_Spec.pdf?1684\" target=\"_blank\" title=\"Megger DET4 Series Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger DET4 Series Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-07-26T08:50:28-06:00","created_at":"2019-07-26T09:10:56-06:00","vendor":"Megger","type":"Earth Ground Testers","tags":[],"price":171000,"price_min":171000,"price_max":468000,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16808744517675,"title":"MEG-DET4TD2","option1":"MEG-DET4TD2","option2":null,"option3":null,"sku":"MEG-DET4TD2","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET4 Series Earth Ground Testers - MEG-DET4TD2","public_title":"MEG-DET4TD2","options":["MEG-DET4TD2"],"price":171000,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":""},{"id":16808744550443,"title":"MEG-DET4TR2","option1":"MEG-DET4TR2","option2":null,"option3":null,"sku":"MEG-DET4TR2","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET4 Series Earth Ground Testers - MEG-DET4TR2","public_title":"MEG-DET4TR2","options":["MEG-DET4TR2"],"price":212000,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":""},{"id":16808744583211,"title":"MEG-DET4TC2","option1":"MEG-DET4TC2","option2":null,"option3":null,"sku":"MEG-DET4TC2","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET4 Series Earth Ground Testers - MEG-DET4TC2","public_title":"MEG-DET4TC2","options":["MEG-DET4TC2"],"price":218000,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":""},{"id":16808744648747,"title":"MEG-DET4TCR2","option1":"MEG-DET4TCR2","option2":null,"option3":null,"sku":"MEG-DET4TCR2","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET4 Series Earth Ground Testers - MEG-DET4TCR2","public_title":"MEG-DET4TCR2","options":["MEG-DET4TCR2"],"price":265000,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":""},{"id":16808744681515,"title":"MEG-DET4TC2+CLAMPS","option1":"MEG-DET4TC2+CLAMPS","option2":null,"option3":null,"sku":"MEG-DET4TC2+CLAMPS","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET4 Series Earth Ground Testers - MEG-DET4TC2+CLAMPS","public_title":"MEG-DET4TC2+CLAMPS","options":["MEG-DET4TC2+CLAMPS"],"price":345000,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":""},{"id":16808744714283,"title":"MEG-DET4TCR2+CLAMPS","option1":"MEG-DET4TCR2+CLAMPS","option2":null,"option3":null,"sku":"MEG-DET4TCR2+CLAMPS","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET4 Series Earth Ground Testers - MEG-DET4TCR2+CLAMPS","public_title":"MEG-DET4TCR2+CLAMPS","options":["MEG-DET4TCR2+CLAMPS"],"price":388000,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":""},{"id":16808744747051,"title":"MEG-DET4TCR2+KIT","option1":"MEG-DET4TCR2+KIT","option2":null,"option3":null,"sku":"MEG-DET4TCR2+KIT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger DET4 Series Earth Ground Testers - MEG-DET4TCR2+KIT","public_title":"MEG-DET4TCR2+KIT","options":["MEG-DET4TCR2+KIT"],"price":468000,"weight":3175,"compare_at_price":null,"inventory_management":"shopify","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/det4td.jpg?v=1564153860"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/det4td.jpg?v=1564153860","options":["Model"],"content":"\u003cp\u003eMegger’s popular 4-terminal ground testing instrument family includes four basic models with different kit variants for each that include select accessories for greater testing flexibility.\u003c\/p\u003e\n\u003cp\u003eThe four basic units are: Model Description DET4TD2 Dry-cell battery powered basic 4-terminal tester DET4TR2 Rechargeable battery powered basic 4-terminal tester DET4TC2 Dry-cell battery powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity and attached rod technique and stakeless measurement capability DET4TCR2 Rechargeable battery powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity and attached rod technique and stakeless measurement capability\u003c\/p\u003e\n\u003cp\u003eThe top-end models (DET4TC2 and DET4TCR2) include a current measuring function for ART (Attached Rod Technique) testing capabilities. With this added function, on-site grounds can be tested separately without having to remove the utility connection (as explained further in this document). They also provide stakeless testing capability. This method allows the operator to use the instrument like a clamp-on ground tester in applications where that method is viable, while also being able to operate as a fall of potential tester if required.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eStakeless testing capability, which allows the operator to use the instrument like a clamp-on tester in applications where the method is viable\u003c\/li\u003e\n\u003cli\u003eAttached Rod Technique capability, which allows fall of potential testing without the need to disconnect the ground rod\u003c\/li\u003e\n\u003cli\u003eMultiple, user selectable test frequencies allow the operator to find the most effective frequency for making the measurement\u003c\/li\u003e\n\u003cli\u003e200,000 Ω measurement range provides the ability to measure the resistivity of any type of soil\u003c\/li\u003e\n\u003cli\u003eUser selectable test voltage ensures that the units can be used in agricultural environments\u003c\/li\u003e\n\u003cli\u003eMicroprocessor control for improved error detection\u003c\/li\u003e\n\u003cli\u003eClear, unambiguous warnings and error indications ensure the reliability of the reading and reduce test time\u003c\/li\u003e\n\u003cli\u003eRugged, weatherproof case to IP54 makes the units truly outdoor instruments\u003c\/li\u003e\n\u003cli\u003eBacklit LCD allows for testing in dark environments\u003c\/li\u003e\n\u003cli\u003eNoise rejection to 40 V pk to pk allows accurate testing in noisy environments\u003c\/li\u003e\n\u003cli\u003eTesting kits and certificates supplied — everything needed to start testing immediately\u003c\/li\u003e\n\u003cli\u003eAccuracy of 2% of reading enhances reliability of measurements\u003c\/li\u003e\n\u003cli\u003eVoltmeter function included allows you to measure the ground voltage and enhances operator safety\u003c\/li\u003e\n\u003cli\u003eCAT IV 100V provides increased operator safety\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"721\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"133\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eSelection Guide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"280\"\u003eModel #\u003c\/td\u003e\n\u003ctd width=\"77\"\u003eDET4TD2\u003c\/td\u003e\n\u003ctd width=\"77\"\u003eDET4TR2\u003c\/td\u003e\n\u003ctd width=\"77\"\u003eDET4TC2\u003c\/td\u003e\n\u003ctd width=\"77\"\u003eDET4TCR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"9\"\u003e\u003cspan\u003e\u003cstrong\u003eTests\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e2-Pole Measurement\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3-Pole Measurement\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-Pole Measurement\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoil Resistivity\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eART Capability\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStakeless Measurement Capability\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e0.01 to 20,000 Ω \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e0.01 to 200,000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Voltage Range\u003c\/td\u003e\n\u003ctd colspan=\"4\" style=\"text-align: center;\"\u003e0 to 100 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Current Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e0.5 mA to 19.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable Voltage (25\/50 V)\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Frequency\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e128 Hz\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"text-align: center;\"\u003e94, 105, 111, 128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAlkaline Batteries\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRechargeable Batteries\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNoise Rejection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 V Peak-to-Peak\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCAT IV 100V\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRated to IP54\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHard Carry Case\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded Accessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTest Leads (49 ft, 33 ft, 33 ft, 10 ft) and Spikes\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e■\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHard Carrying Case\u003c\/li\u003e\n\u003cli\u003e4 x Test Leads (49ft, 33ft, 33ft, 10ft)\u003c\/li\u003e\n\u003cli\u003eSet of Spikes\u003c\/li\u003e\n\u003cli\u003e8 x AA Alkaline Batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_DET4_Series_Spec.pdf?1684\" target=\"_blank\" title=\"Megger DET4 Series Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger DET4 Series Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger DET4 Series Earth Ground Testers

Megger DET4 Series Earth Ground Testers

$4,680.00 CAD

Megger’s popular 4-terminal ground testing instrument family includes four basic models with different kit variants for each that include select accessories for greater testing flexibility. The four basic units are: Model Description DET4TD2 Dry-cell battery powered basic 4-terminal tester DET4TR2 Rechargeable battery powered basic 4-terminal te...


More Info
Megger Digital Earth Clamps

Earth Ground Testers

From $1,960.00 CAD
{"id":1839645392939,"title":"Megger Digital Earth Clamps","handle":"megger-digital-earth-clamps","description":"\u003cdiv style=\"padding-left: 30px;\"\u003eThe DET14C and DET24C represent a new generation of earth\/\u003c\/div\u003e\n\u003cdiv\u003eground clamp-on resistance testers. These instruments induce a\u003c\/div\u003e\n\u003cdiv\u003etest current into earth systems and measure ground resistance\u003c\/div\u003e\n\u003cdiv\u003ein multi ground installations without needing to disconnect the\u003c\/div\u003e\n\u003cdiv\u003eground. They offer market leading access, advanced features, simple\u003c\/div\u003e\n\u003cdiv\u003eoperation and CAT IV 600 V safety protection.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 30px;\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 30px;\"\u003eThe DET14C offers storage of results for later on-screen recall and\u003c\/div\u003e\n\u003cdiv\u003ethe DET24C supports a download of results via Bluetooth® into\u003c\/div\u003e\n\u003cdiv\u003ePowerDB and PowerDB Lite, Megger’s acceptance and maintenance\u003c\/div\u003e\n\u003cdiv\u003etest data management software.\u003c\/div\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eDesigned with flat core ends they prevent dirt build up, ensuring\u003cbr\u003emeasurement integrity and improved reliability over products with\u003cbr\u003einterlocking teeth. Other enhancements over current generation\u003cbr\u003eproducts include improved accuracy and up to 300% increase\u003cbr\u003ein battery life. In electrically noisy environments the built-in filter\u003cbr\u003efunction offers increased noise immunity.\u003cbr\u003e\u003cbr\u003eDET14C and DET24C also offer a true RMS AC current\u003cbr\u003emeasurement facility up to 35 Amps. The instrument’s ability to\u003cbr\u003emeasure current flowing in an earth cable is a useful safety feature,\u003cbr\u003eespecially if the earth cable has to be disconnected. A high current\u003cbr\u003eflow to earth could draw an arc on dis-connection with potentially\u003cbr\u003esevere consequences.\u003cbr\u003e\u003cbr\u003eThe elliptical shaped head design offers improved access to cables\u003cbr\u003eand earth straps in space constrained locations. The clamp head\u003cbr\u003eaccommodates up to 37 mm diameter cable and 50 mm earth tapes\u003cbr\u003emaking them suitable for use in power stations, substations, towers\u003cbr\u003eand many more facilities. Operation in dark and restricted areas is\u003cbr\u003efacilitated by a display with backlight and an audible tone associated\u003cbr\u003ewith the hold key. Optimized jaw opening mechanism ensures proper\u003cbr\u003ejaw closure without excessive use of force when opening the jaws.\u003c\/p\u003e\n\u003cstrong\u003eLarge elliptical clamp (head) design\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAllows testing of round cables\/rods up to 37 mm diameter and ground tapes\/straps up to 50 mm width\u003c\/li\u003e\n\u003cli\u003eImproved testing access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eSmooth mating surfaces on the clamp head\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEasy to clean\u003c\/li\u003e\n\u003cli\u003eNo interlocking teeth to damage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCATIV 600 V operation\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eHighest level of user safety available\u003c\/li\u003e\n\u003cli\u003eUnit can be used safely before the distribution board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eNoise filter function\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUser can select the filter function to increase noise immunity\u003c\/li\u003e\n\u003cli\u003eAllows the unit to be used in higher electrical noise environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eResistance and current limit alarm functions (visual and audible)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMinimum and maximum limits can be set to reduce test time\/improve accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eIntelligent data hold function (preset before testing)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIncreases instrument ease of use in difficult testing locations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eBacklit display\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAllows for operation in low light environments such as cable basements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eTime and date stamped results\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eImproved data\/results management\u003c\/li\u003e\n\u003cli\u003eImproved accuracy of result reporting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eNew ergonomic trigger design\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEasier and more comfortable to operate\u003c\/li\u003e\n\u003cli\u003eLess chance of slippage causing the head to snap shut\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eUltra long battery life (24 hours continuous) with readily available batteries\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eLonger operating time\u003c\/li\u003e\n\u003cli\u003eReduced cost of ownership\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eResistance Measurements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003eGround Resistance Range\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eResolution\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eIntrinsic Certainty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e0.05 Ω to 0.99 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.01 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±1.5% ±0.05 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e1.00 Ω to 9.99 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.01 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±1.5% ± 0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e10.0 Ω to 99.9 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.1 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±2% ± 0.5 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e100.0 Ω to 199.9 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.1 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±5% ± 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e200 Ω to 400 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±6% ± 5 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e400 Ω to 600 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±10% ± 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e600 Ω to 1200 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e1200 Ω to 1500 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±35%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eFrequency of measurement 1390 Hz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCarrying case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCarrying strap (wrist loop) \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUser guide CD-ROM\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCalibration check \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBattery AA (Alkaline) (4 required) \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_DET14C-DET24C_Spec.pdf?1682\" target=\"_blank\" title=\"Megger DET14C and DET24C Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger DET14C and DET24C Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-07-25T11:11:32-06:00","created_at":"2019-07-25T11:18:06-06:00","vendor":"Megger","type":"Earth Ground Testers","tags":[],"price":196000,"price_min":196000,"price_max":225000,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16804230856747,"title":"MEG-DET14C","option1":"MEG-DET14C","option2":null,"option3":null,"sku":"MEG-DET14C","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger Digital Earth Clamps - MEG-DET14C","public_title":"MEG-DET14C","options":["MEG-DET14C"],"price":196000,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":""},{"id":16804230922283,"title":"MEG-DET24C","option1":"MEG-DET24C","option2":null,"option3":null,"sku":"MEG-DET24C","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Megger Digital Earth Clamps - MEG-DET24C","public_title":"MEG-DET24C","options":["MEG-DET24C"],"price":225000,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Megger_DET14C.jpg?v=1564075089"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Megger_DET14C.jpg?v=1564075089","options":["Model"],"content":"\u003cdiv style=\"padding-left: 30px;\"\u003eThe DET14C and DET24C represent a new generation of earth\/\u003c\/div\u003e\n\u003cdiv\u003eground clamp-on resistance testers. These instruments induce a\u003c\/div\u003e\n\u003cdiv\u003etest current into earth systems and measure ground resistance\u003c\/div\u003e\n\u003cdiv\u003ein multi ground installations without needing to disconnect the\u003c\/div\u003e\n\u003cdiv\u003eground. They offer market leading access, advanced features, simple\u003c\/div\u003e\n\u003cdiv\u003eoperation and CAT IV 600 V safety protection.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 30px;\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv style=\"padding-left: 30px;\"\u003eThe DET14C offers storage of results for later on-screen recall and\u003c\/div\u003e\n\u003cdiv\u003ethe DET24C supports a download of results via Bluetooth® into\u003c\/div\u003e\n\u003cdiv\u003ePowerDB and PowerDB Lite, Megger’s acceptance and maintenance\u003c\/div\u003e\n\u003cdiv\u003etest data management software.\u003c\/div\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003eDesigned with flat core ends they prevent dirt build up, ensuring\u003cbr\u003emeasurement integrity and improved reliability over products with\u003cbr\u003einterlocking teeth. Other enhancements over current generation\u003cbr\u003eproducts include improved accuracy and up to 300% increase\u003cbr\u003ein battery life. In electrically noisy environments the built-in filter\u003cbr\u003efunction offers increased noise immunity.\u003cbr\u003e\u003cbr\u003eDET14C and DET24C also offer a true RMS AC current\u003cbr\u003emeasurement facility up to 35 Amps. The instrument’s ability to\u003cbr\u003emeasure current flowing in an earth cable is a useful safety feature,\u003cbr\u003eespecially if the earth cable has to be disconnected. A high current\u003cbr\u003eflow to earth could draw an arc on dis-connection with potentially\u003cbr\u003esevere consequences.\u003cbr\u003e\u003cbr\u003eThe elliptical shaped head design offers improved access to cables\u003cbr\u003eand earth straps in space constrained locations. The clamp head\u003cbr\u003eaccommodates up to 37 mm diameter cable and 50 mm earth tapes\u003cbr\u003emaking them suitable for use in power stations, substations, towers\u003cbr\u003eand many more facilities. Operation in dark and restricted areas is\u003cbr\u003efacilitated by a display with backlight and an audible tone associated\u003cbr\u003ewith the hold key. Optimized jaw opening mechanism ensures proper\u003cbr\u003ejaw closure without excessive use of force when opening the jaws.\u003c\/p\u003e\n\u003cstrong\u003eLarge elliptical clamp (head) design\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAllows testing of round cables\/rods up to 37 mm diameter and ground tapes\/straps up to 50 mm width\u003c\/li\u003e\n\u003cli\u003eImproved testing access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eSmooth mating surfaces on the clamp head\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEasy to clean\u003c\/li\u003e\n\u003cli\u003eNo interlocking teeth to damage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eCATIV 600 V operation\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eHighest level of user safety available\u003c\/li\u003e\n\u003cli\u003eUnit can be used safely before the distribution board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eNoise filter function\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eUser can select the filter function to increase noise immunity\u003c\/li\u003e\n\u003cli\u003eAllows the unit to be used in higher electrical noise environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eResistance and current limit alarm functions (visual and audible)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMinimum and maximum limits can be set to reduce test time\/improve accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eIntelligent data hold function (preset before testing)\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eIncreases instrument ease of use in difficult testing locations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eBacklit display\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAllows for operation in low light environments such as cable basements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eTime and date stamped results\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eImproved data\/results management\u003c\/li\u003e\n\u003cli\u003eImproved accuracy of result reporting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eNew ergonomic trigger design\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eEasier and more comfortable to operate\u003c\/li\u003e\n\u003cli\u003eLess chance of slippage causing the head to snap shut\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstrong\u003eUltra long battery life (24 hours continuous) with readily available batteries\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eLonger operating time\u003c\/li\u003e\n\u003cli\u003eReduced cost of ownership\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"table table-striped\" border=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003eResistance Measurements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003eGround Resistance Range\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eResolution\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eIntrinsic Certainty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e0.05 Ω to 0.99 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.01 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±1.5% ±0.05 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e1.00 Ω to 9.99 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.01 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±1.5% ± 0.1Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e10.0 Ω to 99.9 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.1 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±2% ± 0.5 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e100.0 Ω to 199.9 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.1 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±5% ± 1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e200 Ω to 400 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±6% ± 5 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e400 Ω to 600 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±10% ± 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e600 Ω to 1200 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\"\u003e1200 Ω to 1500 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10 Ω\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e±35%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eFrequency of measurement 1390 Hz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eCarrying case\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCarrying strap (wrist loop) \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eUser guide CD-ROM\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCalibration check \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eBattery AA (Alkaline) (4 required) \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Megger_DET14C-DET24C_Spec.pdf?1682\" target=\"_blank\" title=\"Megger DET14C and DET24C Spec Sheet\" rel=\"noopener noreferrer\"\u003eMegger DET14C and DET24C Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Megger Digital Earth Clamps

Megger Digital Earth Clamps

$2,250.00 CAD

The DET14C and DET24C represent a new generation of earth/ ground clamp-on resistance testers. These instruments induce a test current into earth systems and measure ground resistance in multi ground installations without needing to disconnect the ground. They offer market leading access, advanced features, simple operation and CAT IV 600 V safe...


More Info
Fluke 1630-2 FC Earth Ground Clamp

Earth Ground Testers

$2,533.00 CAD
{"id":1839589490731,"title":"Fluke 1630-2 FC Earth Ground Clamp","handle":"fluke-1630-2-fc-earth-ground-clamp","description":"\u003cp\u003eTest the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes. Stay on line—identify ground loop resistance without the need to disconnect then reconnect the earth electrode from the system.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1630-2 FC Stakeless Earth Ground Clamp is the kind of high-quality, rugged tool you expect from Fluke. Heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eStakeless measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1630-2 FC clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes. You can also perform ground tests in places that were previously difficult: inside buildings, on power pylons or anywhere you don't have access to soil to place auxiliary test stakes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFluke Connect\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eWireless System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1630-2 FC supports the Fluke Connect Wireless System (may not be available in all regions). Fluke Connect wirelessly connects the clamp with an app on your smartphone or tablet. The app shows the ground resistance measurements on your smartphone or tablet display. You can save these measurements, GPS location from your phone and images to Fluke Connect Cloud storage and share with your team.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eEarth ground ac leakage current measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIdentify ac leakage currents without disconnecting the earth ground stake from the grounding system–ideal for system troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRugged\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHeavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLogging measurements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe earth ground clamp saves time by automatically recording data at pre-set intervals and saves up to 32,760 measurements in memory at the set logging interval. Saves time by recording and storing measured values.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm threshold\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUser-defined high\/low alarm limits, for rapid measurement evaluation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBand-pass filter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSelectable band-pass filter function removes unwanted noise from the ac leakage current measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"3\" style=\"height: 21px;\"\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eMaximum voltage to earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003eAA alkaline IEC\/EN LR6 (x4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003eMore than 15 hours*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"3\" style=\"height: 21px;\"\u003e\u003csmall\u003e* In Ground Resistance measurement mode, with backlight turned off, and RF mode turned off\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003e40 Hz to 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eIngress protection\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003eIEC\/EN 60529: IP30 with jaw closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd rowspan=\"2\" style=\"height: 42px;\"\u003eLCD\u003c\/td\u003e\n\u003ctd style=\"height: 21px;\"\u003eDigital reading\u003c\/td\u003e\n\u003ctd style=\"height: 21px;\"\u003e9999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eRefresh rate\u003c\/td\u003e\n\u003ctd style=\"height: 21px;\"\u003e4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"height: 21px;\"\u003e-10 °C to + 50 °C\u003c\/td\u003e\n\u003ctd style=\"height: 21px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEarth Ground clamp\u003c\/li\u003e\n\u003cli\u003eHard case\u003c\/li\u003e\n\u003cli\u003eLoop resistance standard\u003c\/li\u003e\n\u003cli\u003e4 AA batteries\u003c\/li\u003e\n\u003cli\u003eSafety information guide\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1630-2FC_Earth_Ground_Clamp_Spec.PDF?1681\" target=\"_blank\" title=\"Fluke 1630-2 FC Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1630-2 FC Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2019-07-25T10:21:50-06:00","created_at":"2019-07-25T10:27:10-06:00","vendor":"Fluke","type":"Earth Ground Testers","tags":[],"price":253300,"price_min":253300,"price_max":253300,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":16804038049835,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-1630-2FC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1630-2 FC Earth Ground Clamp","public_title":null,"options":["Default Title"],"price":253300,"weight":2268,"compare_at_price":null,"inventory_management":"shopify","barcode":"0 95969 83118 5"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-1630-2.jpg?v=1564072033"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/fluke-1630-2.jpg?v=1564072033","options":["Title"],"content":"\u003cp\u003eTest the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes. Stay on line—identify ground loop resistance without the need to disconnect then reconnect the earth electrode from the system.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1630-2 FC Stakeless Earth Ground Clamp is the kind of high-quality, rugged tool you expect from Fluke. Heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eStakeless measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1630-2 FC clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes. You can also perform ground tests in places that were previously difficult: inside buildings, on power pylons or anywhere you don't have access to soil to place auxiliary test stakes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFluke Connect\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eWireless System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1630-2 FC supports the Fluke Connect Wireless System (may not be available in all regions). Fluke Connect wirelessly connects the clamp with an app on your smartphone or tablet. The app shows the ground resistance measurements on your smartphone or tablet display. You can save these measurements, GPS location from your phone and images to Fluke Connect Cloud storage and share with your team.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eEarth ground ac leakage current measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIdentify ac leakage currents without disconnecting the earth ground stake from the grounding system–ideal for system troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRugged\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHeavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLogging measurements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe earth ground clamp saves time by automatically recording data at pre-set intervals and saves up to 32,760 measurements in memory at the set logging interval. Saves time by recording and storing measured values.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm threshold\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUser-defined high\/low alarm limits, for rapid measurement evaluation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBand-pass filter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSelectable band-pass filter function removes unwanted noise from the ac leakage current measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"3\" style=\"height: 21px;\"\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eMaximum voltage to earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003eAA alkaline IEC\/EN LR6 (x4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003eMore than 15 hours*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"3\" style=\"height: 21px;\"\u003e\u003csmall\u003e* In Ground Resistance measurement mode, with backlight turned off, and RF mode turned off\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003e40 Hz to 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eIngress protection\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003eIEC\/EN 60529: IP30 with jaw closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd rowspan=\"2\" style=\"height: 42px;\"\u003eLCD\u003c\/td\u003e\n\u003ctd style=\"height: 21px;\"\u003eDigital reading\u003c\/td\u003e\n\u003ctd style=\"height: 21px;\"\u003e9999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eRefresh rate\u003c\/td\u003e\n\u003ctd style=\"height: 21px;\"\u003e4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"height: 21px;\"\u003e-10 °C to + 50 °C\u003c\/td\u003e\n\u003ctd style=\"height: 21px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEarth Ground clamp\u003c\/li\u003e\n\u003cli\u003eHard case\u003c\/li\u003e\n\u003cli\u003eLoop resistance standard\u003c\/li\u003e\n\u003cli\u003e4 AA batteries\u003c\/li\u003e\n\u003cli\u003eSafety information guide\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1630-2FC_Earth_Ground_Clamp_Spec.PDF?1681\" target=\"_blank\" title=\"Fluke 1630-2 FC Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1630-2 FC Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 1630-2 FC Earth Ground Clamp

Fluke 1630-2 FC Earth Ground Clamp

$2,533.00 CAD

Test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes. Stay on line—identify ground loop resistance without the need to disconnect then reconnect the earth electrode from the system. The Fluke 1630-2 FC Stakeless Earth Ground Clamp is th...


More Info
Fluke ES-162P4 4-Pole Stake Kit

Earth Ground Testers

$548.00 CAD
{"id":1054514970667,"title":"Fluke ES-162P4 4-Pole Stake Kit","handle":"fluke-es-162p4-4-pole-stake-kit","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eNeeded to perform 3- and 4-Pole Fall of Potential testing (Stake testing) Used with both the Fluke 1623 and Fluke 1625. Already included in the Fluke 1625 Kit.\u003c\/span\u003e","published_at":"2018-02-27T12:42:50-07:00","created_at":"2018-02-27T12:45:10-07:00","vendor":"Fluke","type":"Earth Ground Testers","tags":[],"price":54800,"price_min":54800,"price_max":54800,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":10857542975531,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-ES-162P4-2","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke ES-162P4 4-Pole Stake Kit","public_title":null,"options":["Default Title"],"price":54800,"weight":5000,"compare_at_price":null,"inventory_management":"shopify","barcode":"0 95969 34422 7"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/71Betqp35fL._SL1500.jpg?v=1519760711"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/71Betqp35fL._SL1500.jpg?v=1519760711","options":["Title"],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eNeeded to perform 3- and 4-Pole Fall of Potential testing (Stake testing) Used with both the Fluke 1623 and Fluke 1625. Already included in the Fluke 1625 Kit.\u003c\/span\u003e"}
Fluke ES-162P4 4-Pole Stake Kit

Fluke ES-162P4 4-Pole Stake Kit

$548.00 CAD

Needed to perform 3- and 4-Pole Fall of Potential testing (Stake testing) Used with both the Fluke 1623 and Fluke 1625. Already included in the Fluke 1625 Kit.


More Info
Fluke ES-162P3 3-Pole Stake Kit

Earth Ground Testers

$520.00 CAD
{"id":1054480662571,"title":"Fluke ES-162P3 3-Pole Stake Kit","handle":"fluke-es-162p3-3-pole-stake-kit","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eNeeded to perform 3-Pole Fall of Potential testing (Stake testing) Used with both the Fluke 1623 and Fluke 1625. This is a subset of what is included in the Fluke 1625 Kit.\u003c\/span\u003e","published_at":"2018-02-27T09:51:57-07:00","created_at":"2018-02-27T12:27:26-07:00","vendor":"Fluke","type":"Earth Ground Testers","tags":[],"price":52000,"price_min":52000,"price_max":52000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":10857245081643,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLU-ES-162P3","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke ES-162P3 3-Pole Stake Kit","public_title":null,"options":["Default Title"],"price":52000,"weight":5000,"compare_at_price":null,"inventory_management":"shopify","barcode":"0 95969 34421 0"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/2587-1-1321.jpg?v=1519759648"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/2587-1-1321.jpg?v=1519759648","options":["Title"],"content":"\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eNeeded to perform 3-Pole Fall of Potential testing (Stake testing) Used with both the Fluke 1623 and Fluke 1625. This is a subset of what is included in the Fluke 1625 Kit.\u003c\/span\u003e"}
Fluke ES-162P3 3-Pole Stake Kit

Fluke ES-162P3 3-Pole Stake Kit

$520.00 CAD

Needed to perform 3-Pole Fall of Potential testing (Stake testing) Used with both the Fluke 1623 and Fluke 1625. This is a subset of what is included in the Fluke 1625 Kit.


More Info
Fluke 1625-2 GEO Earth Ground Tester

Earth Ground Testers

From $4,521.00 CAD
{"id":1079430185003,"title":"Fluke 1625-2 GEO Earth Ground Tester","handle":"fluke-1625-2-geo-earth-ground-tester-kit","description":"\u003cp\u003e\u003cspan\u003eThe Fluke 1625-2 offers you simpler, faster earth ground tests than ever before. The 1625-2 offers internal memory storage up to 1500 records, accessible via USB port for rapid data transfer and viewing of results. This earth ground tester also gives you world-class accessories that take the tedium out of earth ground testing. New wire reels speed up setup and tear down time as much as 50%. Heavy duty stakes can be hammered into dry, hard soil. And new color-coded wires make setup simple and help eliminate mistakes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eStakeless Testing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1625-2 earth ground tester is able to measure earth ground loop resistances using only clamps. With this test method, two clamps are placed around the earth ground rod and each are connected to the tester. No earth ground stakes are used at all. A known, fixed voltage is induced by one clamp and the current is measured using the second clamp. Then the tester automatically determines the resistance of the earth ground rod. This test method only works if a bonded earth ground system exists for the building or structure under test, but most are. If there is only one path to ground, like at many residential applications, the Stakeless method will not provide an acceptable value and the Fall of Potential test method must be used.\u003c\/p\u003e\n\u003cp\u003eWith Stakeless testing, the earth ground rod does not need to be disconnected - leaving the bonded earth ground system intact during test. Gone are the days of spending time placing and connecting stakes for each earth ground rod on your system - a major time saver. You can also perform earth ground tests in places you’ve not considered before: inside buildings, power pylons, or anywhere you don’t have access to soil.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Most Complete Tester\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1625-2 is a unique earth ground tester that can performs all four types of earth ground measurement:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3- and 4-Pole Fall-of-Potential (using stakes)\u003c\/li\u003e\n\u003cli\u003e4-Pole Soil Resistivity testing (using stakes)\u003c\/li\u003e\n\u003cli\u003eSelective testing (using 1 clamp and stakes)\u003c\/li\u003e\n\u003cli\u003eStakeless testing (using 2 clamps only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eInternal memory storage up to 1500 records accessible via USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring function\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eInterference voltage and frequency, earthing resistance 3- and 4-pole with\/without clip-on current transformer, resistance 2-pole with AC, 2- and 4-pole with DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e4 digit (2999 Digit) - 7 segment liquid crystal display, with improved visibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCentral rotary switch and function keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eTemperature Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-10°C to 50°C (14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-30°C to 60°C (-22°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±0.1% of reading\/°C \u0026lt; 18°C \u0026gt; 28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of protection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIP56 for case, IP40 for battery door according to EN60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eMax voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWarning – socket \"clamp\" to socket E, ES, S or H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eSockets E, ES, S or H to each other in any combination, max. U\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V (pertains to misuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eProtection by double and\/or reinforced insulation. Max. 50 V to earth per IEC61010-1. Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality standard\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDeveloped, designed and manufactured to comply with DIN ISO 9001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal field influence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eComplies with DIN 43780 (8\/76)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary power\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e6 x 1.5 V alkaline (IEC LR6 or type AA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery life span\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith IEC LR6\/type AA: typ. 3,000 measurements (R\u003csub\u003eE\u003c\/sub\u003e+R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e≤ 1 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eWith IEC LR6\/type AA: typ. 6,000 measurements (R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 10 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤ 1.1 kg (2.43 lb) without accessories 7.6 kg (16.8 lb) incl. accessories and batteries in carrying case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase material\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003ePolyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMeasurement of Interference Voltage DC + AC (U\u003csub\u003eST\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring limits of error: method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eFull wave rectification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.0 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDC\/AC 45 Hz to 400 Hz sine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring sequence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 4 measurements\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 1.5 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMeasurement of Interference Frequency (F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring limits of error: method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMeasurement of oscillation period of the interference voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e6.0 Hz to 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e16.0 Hz to 299.9 Hz to 999 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Hz to 1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(1% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eEarthing Resistance (RE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCurrent and voltage measurement with probe as IEC61557-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e20\/48 V, AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e94, 105, 111, 128 Hz selected manually or automatic. (AFC) 55 Hz in function R\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise rejection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e120 dB (16 2\/3 , 50 , 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eElectrical Measurement Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd\u003eIntrinsic Error or Influence Quantity\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eReference Conditions or Specified Operating Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eDesignation Code\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRequirements or Test in Accordance with the Relevant Parts of IEC 1557\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eType of Test\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic error\u003c\/td\u003e\n\u003ctd\u003eReference conditions\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003ePart 5, 6.1\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition\u003c\/td\u003e\n\u003ctd\u003eReference position ±90°\u003c\/td\u003e\n\u003ctd\u003eE1\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003eAt the limits stated by the manufacturer\u003c\/td\u003e\n\u003ctd\u003eE2\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2, 4.3\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0°C and 35°C\u003c\/td\u003e\n\u003ctd\u003eE3\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries interference voltage\u003c\/td\u003e\n\u003ctd\u003eSee 4.2 and 4.3\u003c\/td\u003e\n\u003ctd\u003eE4\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.2, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance of the probes and auxiliary earth electrodes\u003c\/td\u003e\n\u003ctd\u003e0 to 100 x R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ebut ≤ 50 kΩ\u003c\/td\u003e\n\u003ctd\u003eE5\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem frequency\u003c\/td\u003e\n\u003ctd\u003e99% to 101% of the nominal frequency\u003c\/td\u003e\n\u003ctd\u003eE7\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem voltage\u003c\/td\u003e\n\u003ctd\u003e85% to 110% of the nominal voltage\u003c\/td\u003e\n\u003ctd\u003eE8\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eB = ±(|A| + 1,15 √E\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e1\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e2\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e3\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e4\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e5\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e6\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"4\"\u003eB[%] = ± B\/fiducial value x 100%\u003cbr\u003e\u003cbr\u003eA = intrinsic error\u003cbr\u003eE\u003csub\u003en\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= variations\u003cbr\u003eR = routine test\u003cbr\u003eT = type test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.300 kΩ to 2.999 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTypical 8 seconds with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error because of probe-and auxiliary earth electrode resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eR\u003csub\u003eH\u003c\/sub\u003e(R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ 2000 Ω)\/R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ex 1.25 x 10\u003csup\u003e-6\u003c\/sup\u003e% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring error of R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTyp. 10% of R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. probe resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. auxiliary earth electrode resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp\u003eAutomatic check if error is kept within the limits required by IEC61557-5.\u003cbr\u003eIf after a measurement of probe-, auxiliary earth electrode- and earthing resistance, a measurement error of higher than 30% is assumed because of the influencing conditions, the display shows a warning symbol and a notice that RS or RH are too high.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAutomatic Switchover of Measuring Resolution in Dependence to Auxiliary Earth Electrode Resistance R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRH with U\u003csub\u003emeas\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 48 V\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 300 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 6 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 60 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 600 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRH with U\u003csub\u003emeas\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 20 V\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 250 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 2.5 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 25 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eSelective Measurement of the Earthing Resistance (R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eClamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCurrent and voltage measurement with probe as per EN61557-5 and current measurement in the individual branch with additional current transformer (patent applied for).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e20\/48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e94, 105, 111, 128 Hz selected manually or automatically (AFC), 55 Hz (R\u003csup\u003e1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise rejection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e120 dB (162\/3, 50, 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMax. U\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V (measurement will not be started)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.300 kΩ to 2.999 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(7% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(10% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error because of probe- and auxiliary earth typ. electrode resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eR\u003csub\u003eH\u003c\/sub\u003e(R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ 2000 Ω)\/R\u003csub\u003eETOTAL\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ex 1.25 x 10\u003csup\u003e-6\u003c\/sup\u003e% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring error of R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTyp. of 10% of R\u003csub\u003eETOTAL\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTyp. 8 sec. with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMinimal current in single branch to be measured\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e0.5 mA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eWith transformer (1000:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e0.1 mA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eWith transformer (200:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. interference current through transformer\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e3 A\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eWith transformer (1000:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"5\"\u003e1. With recommended current clamps\/transformers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eResistance Measurement (R~)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCurrent and voltage measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e20 V AC, square pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026gt; 250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e94, 105, 111, 128 Hz selected manually or automatically (AFC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e300 Ω to 2999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTypical 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. interference voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e24 V, with higher voltages measurement will not be started\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003emax. = 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eResistance Measurement (R DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCurrent- voltage measurement as per IEC61557-4 possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e20 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e250 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormation of measured value\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith 4-pole measurement wires on H, S, ES can be extended without additional error.\u003cbr\u003eResistances \u0026gt; 1 Ω in wire E can cause additional error of 5m Ω\/Ω.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e300 Ω to 2999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.0 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring sequence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 2 measurements\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTypical 4 second including reversal of polarity (2-pole or 4-pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum interference voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤ 3 V AC or DC, with higher voltages measurement will not be started\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum inductivity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2 Henry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eCompensation of Lead Resistance (R\u003csub\u003eK\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\"\u003eCompensation of lead resistance (R\u003csub\u003eK\u003c\/sub\u003e) can be switched on in functions R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole, R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole (clamp), R AC, and R DC 2-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormation of measured value\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eR\u003csub\u003edisplay\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= R\u003csub\u003emeasured\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e- R\u003csub\u003ecompensated\u003c\/sub\u003e\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"5\"\u003e2. Value of setpoint entry RK = 0.000 Ω, variable from 0.000 to 29.99 Ω by means of measuring adjustment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eStakeless Ground Loop Measurement (Two Clamp Stakeless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eRA 4-pole (two clamp Stakeless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.02 Ω to 199.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(7% rdg + 3 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(10% rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eVm = 48 V AC (primary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eNoise current (IEXT)\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eMax. IEXT = 10 A (AC) (RA \u0026lt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eMax. IEXT = 2 A (AC) (RA \u0026gt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003eFluke 1625-2 GEO Earth Ground Tester\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cul\u003e\n\u003cli\u003eGEO Earth Ground Tester\u003c\/li\u003e\n\u003cli\u003eUser's Manual\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eQuick Reference Guide\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003eFluke 1625-2 GEO Earth Ground Tester Kit\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cul\u003e\n\u003cli\u003eGEO Earth Ground Tester\u003c\/li\u003e\n\u003cli\u003eUser’s Manual\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eQuick Reference Guide\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003cli\u003e2 Clamps\u003c\/li\u003e\n\u003cli\u003eC1620 Professional Carrying Case\u003c\/li\u003e\n\u003cli\u003e4 Earth Ground Stakes\u003c\/li\u003e\n\u003cli\u003e3 Cable Reels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1623-2_1625-2_Earth_Ground_Testing.PDF?1808\" target=\"_blank\" title=\"Fluke 1625-2 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1625-2 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-03-08T16:50:47-07:00","created_at":"2018-03-08T16:52:43-07:00","vendor":"Fluke","type":"Earth Ground Testers","tags":[],"price":452100,"price_min":452100,"price_max":589000,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11068917350443,"title":"FLU-1625-2","option1":"FLU-1625-2","option2":null,"option3":null,"sku":"FLU-1625-2","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1625-2 GEO Earth Ground Tester - FLU-1625-2","public_title":"FLU-1625-2","options":["FLU-1625-2"],"price":452100,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"0 95969 66685 5"},{"id":30265581109291,"title":"FLU-1625-2-KIT","option1":"FLU-1625-2-KIT","option2":null,"option3":null,"sku":"FLU-1625-2-KIT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1625-2 GEO Earth Ground Tester - FLU-1625-2-KIT","public_title":"FLU-1625-2-KIT","options":["FLU-1625-2-KIT"],"price":589000,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"0 95969 66687 9"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke_1625-2_KIT_01-2.jpg?v=1520553165","\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/1625-2-Kit.jpg?v=1569531224"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke_1625-2_KIT_01-2.jpg?v=1520553165","options":["Model"],"content":"\u003cp\u003e\u003cspan\u003eThe Fluke 1625-2 offers you simpler, faster earth ground tests than ever before. The 1625-2 offers internal memory storage up to 1500 records, accessible via USB port for rapid data transfer and viewing of results. This earth ground tester also gives you world-class accessories that take the tedium out of earth ground testing. New wire reels speed up setup and tear down time as much as 50%. Heavy duty stakes can be hammered into dry, hard soil. And new color-coded wires make setup simple and help eliminate mistakes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eStakeless Testing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1625-2 earth ground tester is able to measure earth ground loop resistances using only clamps. With this test method, two clamps are placed around the earth ground rod and each are connected to the tester. No earth ground stakes are used at all. A known, fixed voltage is induced by one clamp and the current is measured using the second clamp. Then the tester automatically determines the resistance of the earth ground rod. This test method only works if a bonded earth ground system exists for the building or structure under test, but most are. If there is only one path to ground, like at many residential applications, the Stakeless method will not provide an acceptable value and the Fall of Potential test method must be used.\u003c\/p\u003e\n\u003cp\u003eWith Stakeless testing, the earth ground rod does not need to be disconnected - leaving the bonded earth ground system intact during test. Gone are the days of spending time placing and connecting stakes for each earth ground rod on your system - a major time saver. You can also perform earth ground tests in places you’ve not considered before: inside buildings, power pylons, or anywhere you don’t have access to soil.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Most Complete Tester\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1625-2 is a unique earth ground tester that can performs all four types of earth ground measurement:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3- and 4-Pole Fall-of-Potential (using stakes)\u003c\/li\u003e\n\u003cli\u003e4-Pole Soil Resistivity testing (using stakes)\u003c\/li\u003e\n\u003cli\u003eSelective testing (using 1 clamp and stakes)\u003c\/li\u003e\n\u003cli\u003eStakeless testing (using 2 clamps only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eInternal memory storage up to 1500 records accessible via USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring function\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eInterference voltage and frequency, earthing resistance 3- and 4-pole with\/without clip-on current transformer, resistance 2-pole with AC, 2- and 4-pole with DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e4 digit (2999 Digit) - 7 segment liquid crystal display, with improved visibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCentral rotary switch and function keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eTemperature Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-10°C to 50°C (14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-30°C to 60°C (-22°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±0.1% of reading\/°C \u0026lt; 18°C \u0026gt; 28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of protection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eIP56 for case, IP40 for battery door according to EN60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eMax voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWarning – socket \"clamp\" to socket E, ES, S or H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eSockets E, ES, S or H to each other in any combination, max. U\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V (pertains to misuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eProtection by double and\/or reinforced insulation. Max. 50 V to earth per IEC61010-1. Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality standard\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDeveloped, designed and manufactured to comply with DIN ISO 9001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal field influence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eComplies with DIN 43780 (8\/76)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary power\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e6 x 1.5 V alkaline (IEC LR6 or type AA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eBattery life span\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith IEC LR6\/type AA: typ. 3,000 measurements (R\u003csub\u003eE\u003c\/sub\u003e+R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e≤ 1 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eWith IEC LR6\/type AA: typ. 6,000 measurements (R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 10 kΩ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤ 1.1 kg (2.43 lb) without accessories 7.6 kg (16.8 lb) incl. accessories and batteries in carrying case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase material\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003ePolyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMeasurement of Interference Voltage DC + AC (U\u003csub\u003eST\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring limits of error: method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eFull wave rectification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.0 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDC\/AC 45 Hz to 400 Hz sine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring sequence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 4 measurements\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 1.5 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eMeasurement of Interference Frequency (F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring limits of error: method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMeasurement of oscillation period of the interference voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e6.0 Hz to 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e16.0 Hz to 299.9 Hz to 999 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.1 Hz to 1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 V to 50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(1% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eEarthing Resistance (RE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCurrent and voltage measurement with probe as IEC61557-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e20\/48 V, AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e94, 105, 111, 128 Hz selected manually or automatic. (AFC) 55 Hz in function R\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise rejection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e120 dB (16 2\/3 , 50 , 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eElectrical Measurement Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd\u003eIntrinsic Error or Influence Quantity\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eReference Conditions or Specified Operating Range\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eDesignation Code\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eRequirements or Test in Accordance with the Relevant Parts of IEC 1557\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eType of Test\u003c\/b\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic error\u003c\/td\u003e\n\u003ctd\u003eReference conditions\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003ePart 5, 6.1\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition\u003c\/td\u003e\n\u003ctd\u003eReference position ±90°\u003c\/td\u003e\n\u003ctd\u003eE1\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003eAt the limits stated by the manufacturer\u003c\/td\u003e\n\u003ctd\u003eE2\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2, 4.3\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0°C and 35°C\u003c\/td\u003e\n\u003ctd\u003eE3\u003c\/td\u003e\n\u003ctd\u003ePart 1, 4.2\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries interference voltage\u003c\/td\u003e\n\u003ctd\u003eSee 4.2 and 4.3\u003c\/td\u003e\n\u003ctd\u003eE4\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.2, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance of the probes and auxiliary earth electrodes\u003c\/td\u003e\n\u003ctd\u003e0 to 100 x R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ebut ≤ 50 kΩ\u003c\/td\u003e\n\u003ctd\u003eE5\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem frequency\u003c\/td\u003e\n\u003ctd\u003e99% to 101% of the nominal frequency\u003c\/td\u003e\n\u003ctd\u003eE7\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem voltage\u003c\/td\u003e\n\u003ctd\u003e85% to 110% of the nominal voltage\u003c\/td\u003e\n\u003ctd\u003eE8\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eB = ±(|A| + 1,15 √E\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e1\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e2\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e3\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e4\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e5\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eE\u003csup\u003e2\u003c\/sup\u003e\u003csub\u003e6\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003ePart 5, 4.3\u003c\/td\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"4\"\u003eB[%] = ± B\/fiducial value x 100%\u003cbr\u003e\u003cbr\u003eA = intrinsic error\u003cbr\u003eE\u003csub\u003en\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= variations\u003cbr\u003eR = routine test\u003cbr\u003eT = type test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.300 kΩ to 2.999 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTypical 8 seconds with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error because of probe-and auxiliary earth electrode resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eR\u003csub\u003eH\u003c\/sub\u003e(R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ 2000 Ω)\/R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ex 1.25 x 10\u003csup\u003e-6\u003c\/sup\u003e% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring error of R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTyp. 10% of R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. probe resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. auxiliary earth electrode resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤ 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\n\u003cp\u003eAutomatic check if error is kept within the limits required by IEC61557-5.\u003cbr\u003eIf after a measurement of probe-, auxiliary earth electrode- and earthing resistance, a measurement error of higher than 30% is assumed because of the influencing conditions, the display shows a warning symbol and a notice that RS or RH are too high.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eAutomatic Switchover of Measuring Resolution in Dependence to Auxiliary Earth Electrode Resistance R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRH with U\u003csub\u003emeas\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 48 V\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 300 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 6 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 60 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 600 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eRH with U\u003csub\u003emeas\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 20 V\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 250 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 2.5 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 25 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e\u0026lt; 250 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e1 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 mΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eSelective Measurement of the Earthing Resistance (R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eClamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCurrent and voltage measurement with probe as per EN61557-5 and current measurement in the individual branch with additional current transformer (patent applied for).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e20\/48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e94, 105, 111, 128 Hz selected manually or automatically (AFC), 55 Hz (R\u003csup\u003e1\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise rejection\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e120 dB (162\/3, 50, 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eMax. U\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V (measurement will not be started)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.300 kΩ to 2.999 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(7% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(10% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error because of probe- and auxiliary earth typ. electrode resistance\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eR\u003csub\u003eH\u003c\/sub\u003e(R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ 2000 Ω)\/R\u003csub\u003eETOTAL\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ex 1.25 x 10\u003csup\u003e-6\u003c\/sup\u003e% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring error of R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTyp. of 10% of R\u003csub\u003eETOTAL\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e+ R\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTyp. 8 sec. with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eMinimal current in single branch to be measured\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e0.5 mA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eWith transformer (1000:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cb\u003e0.1 mA\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eWith transformer (200:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. interference current through transformer\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e3 A\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eWith transformer (1000:1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"5\"\u003e1. With recommended current clamps\/transformers.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eResistance Measurement (R~)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCurrent and voltage measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e20 V AC, square pulse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026gt; 250 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e94, 105, 111, 128 Hz selected manually or automatically (AFC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e300 Ω to 2999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTypical 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. interference voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e24 V, with higher voltages measurement will not be started\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003emax. = 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eResistance Measurement (R DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eCurrent- voltage measurement as per IEC61557-4 possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e20 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e250 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormation of measured value\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWith 4-pole measurement wires on H, S, ES can be extended without additional error.\u003cbr\u003eResistances \u0026gt; 1 Ω in wire E can cause additional error of 5m Ω\/Ω.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.020 Ω to 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eDisplay range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 2.999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.00 Ω to 29.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 Ω to 299.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e300 Ω to 2999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e3.0 kΩ to 29.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e30.0 kΩ to 299.9 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(2% of rdg + 2 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(5% of rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring sequence\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eApprox. 2 measurements\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eTypical 4 second including reversal of polarity (2-pole or 4-pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum interference voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≤ 3 V AC or DC, with higher voltages measurement will not be started\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum inductivity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2 Henry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum overload\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eU\u003csub\u003erms\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eCompensation of Lead Resistance (R\u003csub\u003eK\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"5\"\u003eCompensation of lead resistance (R\u003csub\u003eK\u003c\/sub\u003e) can be switched on in functions R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole, R\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole (clamp), R AC, and R DC 2-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormation of measured value\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eR\u003csub\u003edisplay\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= R\u003csub\u003emeasured\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e- R\u003csub\u003ecompensated\u003c\/sub\u003e\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold small-font\" colspan=\"5\"\u003e2. Value of setpoint entry RK = 0.000 Ω, variable from 0.000 to 29.99 Ω by means of measuring adjustment.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"5\"\u003eStakeless Ground Loop Measurement (Two Clamp Stakeless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eRA 4-pole (two clamp Stakeless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.001 Ω to 0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e0.02 Ω to 199.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(7% rdg + 3 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e±(10% rdg + 5 digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eVm = 48 V AC (primary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eNoise current (IEXT)\u003c\/td\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eMax. IEXT = 10 A (AC) (RA \u0026lt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"4\"\u003eMax. IEXT = 2 A (AC) (RA \u0026gt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003eFluke 1625-2 GEO Earth Ground Tester\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cul\u003e\n\u003cli\u003eGEO Earth Ground Tester\u003c\/li\u003e\n\u003cli\u003eUser's Manual\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eQuick Reference Guide\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003eFluke 1625-2 GEO Earth Ground Tester Kit\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cul\u003e\n\u003cli\u003eGEO Earth Ground Tester\u003c\/li\u003e\n\u003cli\u003eUser’s Manual\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eQuick Reference Guide\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003cli\u003e2 Clamps\u003c\/li\u003e\n\u003cli\u003eC1620 Professional Carrying Case\u003c\/li\u003e\n\u003cli\u003e4 Earth Ground Stakes\u003c\/li\u003e\n\u003cli\u003e3 Cable Reels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1623-2_1625-2_Earth_Ground_Testing.PDF?1808\" target=\"_blank\" title=\"Fluke 1625-2 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1625-2 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 1625-2 GEO Earth Ground Tester

Fluke 1625-2 GEO Earth Ground Tester

$5,890.00 CAD

The Fluke 1625-2 offers you simpler, faster earth ground tests than ever before. The 1625-2 offers internal memory storage up to 1500 records, accessible via USB port for rapid data transfer and viewing of results. This earth ground tester also gives you world-class accessories that take the tedium out of earth ground testing. New wire reels spe...


More Info
Fluke 1623-2 GEO Earth Ground Resistance Meter

Earth Ground Testers

From $2,740.00 CAD
{"id":1078754869291,"title":"Fluke 1623-2 GEO Earth Ground Resistance Meter","handle":"fluke-1623-2-kit-geo-earth-ground-tester-kit","description":"\u003cp\u003e\u003cstrong\u003eFluke 1623-2 Earth Ground Tester performs all four ground tests quickly and accurately.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1623-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1623-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps. This technique eliminates the dangerous, and time consuming job of disconnecting parallel grounds, and finding suitable locations for auxiliary ground stakes. You can use it to perform earth ground tests in places you’ve not considered before, such as inside buildings, on power pylons, or anywhere you don’t have access to soil.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eA unique earth ground tester that performs fast, accurate testing with and without stakes\u003c\/li\u003e\n\u003cli\u003eTests 3- and 4-pole fall-of-potential, and 4-pole soil resistivity (with stakes)\u003c\/li\u003e\n\u003cli\u003ePerforms selective earth ground rod testing (one clamp + stakes)\u003c\/li\u003e\n\u003cli\u003ePerforms stakeless earth ground rod testing (two clamps)\u003c\/li\u003e\n\u003cli\u003eFeatures IP56 rating for outdoor use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"width: 35%;\"\u003eDisplay: 1999 digit LCD\u003c\/td\u003e\n\u003ctd\u003eDisplay with special symbols, digit height 25 mm, fluorescent backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser interface\u003c\/td\u003e\n\u003ctd\u003eInstant measurement through TURN and START one button concept. The only operating elements are rotary switch and START button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRobust, water and dust resistant\u003c\/td\u003e\n\u003ctd\u003eInstrument is designed for tough environmental conditions (rubber protective cover, IP56)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eInternal memory storage up to 1500 records accessible via USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eTemperature Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C (14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to 60°C (-22°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd\u003e±0.1% of reading\/°C \u0026lt; 18°C \u0026gt; 28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic error\u003c\/td\u003e\n\u003ctd\u003eRefers to the reference temperature range and is guaranteed for 1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003eRefers to the operating temperature range and is guaranteed for 1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClimatic class\u003c\/td\u003e\n\u003ctd\u003eC1 (IEC 654-1), -5°C to +45°C (23° to +115° F), 5% to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective type\u003c\/td\u003e\n\u003ctd\u003eIP56 for case, IP40 for battery door according to EN60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eProtection by double and\/or reinforced insulation. max. 50 V to earth. IEC61010-1: Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC (emission immunity)\u003c\/td\u003e\n\u003ctd\u003eIEC61326-1: Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality system\u003c\/td\u003e\n\u003ctd\u003eDeveloped, designed and manufactured according to DIN ISO 9001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal voltage\u003c\/td\u003e\n\u003ctd\u003eV ext, max = 24 V (DC, AC \u0026lt; 400 Hz), measurement inhibited for higher values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV ext rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 120 dB (162⁄3, 50, 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd\u003eTypical 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd\u003e250 V rms (pertains to misuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary power\u003c\/td\u003e\n\u003ctd\u003e6 x 1.5 V Alkaline (type AA LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life span\u003c\/td\u003e\n\u003ctd\u003eTypical \u0026gt; 3,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.1 kg (2.43 lb) including batteries\u003cbr\u003e7.6 kg (16.8 lb) incl. accessories and batteries in carrying case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eRA 3-Pole Ground Resistance Measurement (IEC 1557-5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(5% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error from R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eH\u003c\/sub\u003e[kΩ]•••R\u003csub\u003eS\u003c\/sub\u003e[kΩ]\/R\u003csub\u003eA\u003c\/sub\u003e[Ω]•••0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-Pole Ground Resistance Measurement (IEC 1557-5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(5% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS +\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003eR\u003csub\u003eES\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error from R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eH\u003c\/sub\u003e[kΩ]•••R\u003csub\u003eS\u003c\/sub\u003e[kΩ]\/R\u003csub\u003eA\u003c\/sub\u003e[Ω]•••0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eRA 3-Pole Selective Ground Resistance Measurement with Current Clamp (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith Clamp )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole with clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement (with External Current Clamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eRA 4-Pole Selective Ground Resistance Measurement with Current Clamp (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith Clamp )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole with clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement (with External Current Clamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eStakeless Ground Loop Measurement (2 Clamps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole 2 clamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Stakeless Measurement of Resistance in Closed Loops Using Two Current Transformers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eNoise current (I\u003csub\u003eEXT\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax. I\u003csub\u003eEXT\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 10 A (AC) (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026lt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eMax. I\u003csub\u003eEXT\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 2 A (AC) (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003eFluke 1623-2 GEO Earth Ground Tester\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cul\u003e\n\u003cli\u003eGEO Earth Ground Tester\u003c\/li\u003e\n\u003cli\u003eUser's Manual\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eQuick Reference Guide\u003c\/li\u003e\n\u003cli\u003e2 Test Leads\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003eFluke 1623-2 GEO Earth Ground Tester Kit\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cul\u003e\n\u003cli\u003eGEO Earth Ground Tester\u003c\/li\u003e\n\u003cli\u003eUser’s Manual\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eQuick Reference Guide\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003cli\u003e2 Clamps\u003c\/li\u003e\n\u003cli\u003eC1620 Professional Carrying Case\u003c\/li\u003e\n\u003cli\u003e4 Earth Ground Stakes\u003c\/li\u003e\n\u003cli\u003e3 Cable Reels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1623-2_1625-2_Earth_Ground_Testing.PDF?1808\" target=\"_blank\" title=\"Fluke 1623-2 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1623-2 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-03-08T11:01:34-07:00","created_at":"2018-03-08T11:05:16-07:00","vendor":"Fluke","type":"Earth Ground Testers","tags":[],"price":274000,"price_min":274000,"price_max":452100,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11060981923883,"title":"FLU-1623-2","option1":"FLU-1623-2","option2":null,"option3":null,"sku":"FLU-1623-2","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1623-2 GEO Earth Ground Resistance Meter - FLU-1623-2","public_title":"FLU-1623-2","options":["FLU-1623-2"],"price":274000,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"0 95969 66684 8"},{"id":30265567182891,"title":"FLU-1623-2-KIT","option1":"FLU-1623-2-KIT","option2":null,"option3":null,"sku":"FLU-1623-2-KIT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1623-2 GEO Earth Ground Resistance Meter - FLU-1623-2-KIT","public_title":"FLU-1623-2-KIT","options":["FLU-1623-2-KIT"],"price":452100,"weight":6804,"compare_at_price":null,"inventory_management":"shopify","barcode":"0 95969 66686 2"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke_1623-2_ac485795-0c45-4f47-9056-0a330a3528c9.jpg?v=1569529320","\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke_1623-2.jpg?v=1569529320","\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/1623-2-Kit.jpg?v=1569529390"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/Fluke_1623-2_ac485795-0c45-4f47-9056-0a330a3528c9.jpg?v=1569529320","options":["Model"],"content":"\u003cp\u003e\u003cstrong\u003eFluke 1623-2 Earth Ground Tester performs all four ground tests quickly and accurately.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1623-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1623-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps. This technique eliminates the dangerous, and time consuming job of disconnecting parallel grounds, and finding suitable locations for auxiliary ground stakes. You can use it to perform earth ground tests in places you’ve not considered before, such as inside buildings, on power pylons, or anywhere you don’t have access to soil.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eA unique earth ground tester that performs fast, accurate testing with and without stakes\u003c\/li\u003e\n\u003cli\u003eTests 3- and 4-pole fall-of-potential, and 4-pole soil resistivity (with stakes)\u003c\/li\u003e\n\u003cli\u003ePerforms selective earth ground rod testing (one clamp + stakes)\u003c\/li\u003e\n\u003cli\u003ePerforms stakeless earth ground rod testing (two clamps)\u003c\/li\u003e\n\u003cli\u003eFeatures IP56 rating for outdoor use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"width: 35%;\"\u003eDisplay: 1999 digit LCD\u003c\/td\u003e\n\u003ctd\u003eDisplay with special symbols, digit height 25 mm, fluorescent backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser interface\u003c\/td\u003e\n\u003ctd\u003eInstant measurement through TURN and START one button concept. The only operating elements are rotary switch and START button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRobust, water and dust resistant\u003c\/td\u003e\n\u003ctd\u003eInstrument is designed for tough environmental conditions (rubber protective cover, IP56)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eInternal memory storage up to 1500 records accessible via USB port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eTemperature Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C (14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to 60°C (-22°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd\u003e±0.1% of reading\/°C \u0026lt; 18°C \u0026gt; 28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic error\u003c\/td\u003e\n\u003ctd\u003eRefers to the reference temperature range and is guaranteed for 1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003eRefers to the operating temperature range and is guaranteed for 1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClimatic class\u003c\/td\u003e\n\u003ctd\u003eC1 (IEC 654-1), -5°C to +45°C (23° to +115° F), 5% to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective type\u003c\/td\u003e\n\u003ctd\u003eIP56 for case, IP40 for battery door according to EN60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eProtection by double and\/or reinforced insulation. max. 50 V to earth. IEC61010-1: Pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC (emission immunity)\u003c\/td\u003e\n\u003ctd\u003eIEC61326-1: Portable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuality system\u003c\/td\u003e\n\u003ctd\u003eDeveloped, designed and manufactured according to DIN ISO 9001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal voltage\u003c\/td\u003e\n\u003ctd\u003eV ext, max = 24 V (DC, AC \u0026lt; 400 Hz), measurement inhibited for higher values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV ext rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 120 dB (162⁄3, 50, 60, 400 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd\u003eTypical 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. overload\u003c\/td\u003e\n\u003ctd\u003e250 V rms (pertains to misuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary power\u003c\/td\u003e\n\u003ctd\u003e6 x 1.5 V Alkaline (type AA LR6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life span\u003c\/td\u003e\n\u003ctd\u003eTypical \u0026gt; 3,000 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.1 kg (2.43 lb) including batteries\u003cbr\u003e7.6 kg (16.8 lb) incl. accessories and batteries in carrying case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eRA 3-Pole Ground Resistance Measurement (IEC 1557-5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(5% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error from R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eH\u003c\/sub\u003e[kΩ]•••R\u003csub\u003eS\u003c\/sub\u003e[kΩ]\/R\u003csub\u003eA\u003c\/sub\u003e[Ω]•••0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-Pole Ground Resistance Measurement (IEC 1557-5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(2% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(5% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS +\u003cspan\u003e \u003c\/span\u003e\u003c\/sub\u003eR\u003csub\u003eES\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional error from R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eS\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eH\u003c\/sub\u003e[kΩ]•••R\u003csub\u003eS\u003c\/sub\u003e[kΩ]\/R\u003csub\u003eA\u003c\/sub\u003e[Ω]•••0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eRA 3-Pole Selective Ground Resistance Measurement with Current Clamp (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith Clamp )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e3-pole with clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement (with External Current Clamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eRA 4-Pole Selective Ground Resistance Measurement with Current Clamp (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith Clamp )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole with clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Current\/Voltage Measurement (with External Current Clamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe resistance (R\u003csub\u003eS\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary earth electrode resistance (R\u003csub\u003eH\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax 100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003eMonitoring of R\u003csub\u003eS\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eand R\u003csub\u003eH\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003ewith error indicator.\u003cbr\u003eAutomatic range selection.\u003cbr\u003eMeasurement is not performed if the current through the current clamp is too low.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eStakeless Ground Loop Measurement (2 Clamps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch position\u003c\/td\u003e\n\u003ctd\u003eR\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e4-pole 2 clamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Ω to 10 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range\u003c\/td\u003e\n\u003ctd\u003e0.020 Ω to 19.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±(7% rdg + 3 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating error\u003c\/td\u003e\n\u003ctd\u003e±(10% rdg + 5 d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasuring Principle: Stakeless Measurement of Resistance in Closed Loops Using Two Current Transformers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring voltage\u003c\/td\u003e\n\u003ctd\u003eVm = 48 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasure frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eNoise current (I\u003csub\u003eEXT\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003eMax. I\u003csub\u003eEXT\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 10 A (AC) (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026lt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eMax. I\u003csub\u003eEXT\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e= 2 A (AC) (R\u003csub\u003eA\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 20 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003eFluke 1623-2 GEO Earth Ground Tester\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cul\u003e\n\u003cli\u003eGEO Earth Ground Tester\u003c\/li\u003e\n\u003cli\u003eUser's Manual\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eQuick Reference Guide\u003c\/li\u003e\n\u003cli\u003e2 Test Leads\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003eFluke 1623-2 GEO Earth Ground Tester Kit\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cul\u003e\n\u003cli\u003eGEO Earth Ground Tester\u003c\/li\u003e\n\u003cli\u003eUser’s Manual\u003c\/li\u003e\n\u003cli\u003eBatteries\u003c\/li\u003e\n\u003cli\u003eQuick Reference Guide\u003c\/li\u003e\n\u003cli\u003eUSB Cable\u003c\/li\u003e\n\u003cli\u003e2 Clamps\u003c\/li\u003e\n\u003cli\u003eC1620 Professional Carrying Case\u003c\/li\u003e\n\u003cli\u003e4 Earth Ground Stakes\u003c\/li\u003e\n\u003cli\u003e3 Cable Reels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1623-2_1625-2_Earth_Ground_Testing.PDF?1808\" target=\"_blank\" title=\"Fluke 1623-2 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1623-2 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 1623-2 GEO Earth Ground Resistance Meter

Fluke 1623-2 GEO Earth Ground Resistance Meter

$4,521.00 CAD

Fluke 1623-2 Earth Ground Tester performs all four ground tests quickly and accurately. The Fluke 1623-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1623-2 is able to measure earth ground loop resistances for multi-grounded systems u...


More Info
Fluke 1621 GEO Earth Ground Tester

Earth Ground Testers

From $2,055.00 CAD
{"id":1076387610667,"title":"Fluke 1621 GEO Earth Ground Tester","handle":"fluke-1621-earth-ground-tester-kit","description":"\u003cp\u003e\u003cspan\u003eThe Fluke 1621 is an easy-to-use earth ground tester. For ground resistance testing, the 1621 is the first line of defense in detecting reliable ground connections. The unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance tests. Its convenient size, rugged holster, and large, clear LCD display make it an ideal field earth ground tester, for most electrical grounding work environments. With a simple user interface and intuitive functionality, the Fluke 1621 is a handy grounding tool for electrical contractors, utility test engineers, and earth ground specialists.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 1621 Kit is an easy-to-use earth ground tester. For ground resistance testing, the 1621 Kit is the first line of defense in detecting reliable ground connections. The unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance tests. Its convenient size, rugged holster, and large, clear LCD display make it an ideal field earth ground tester, for most electrical grounding work environments. With a simple user interface and intuitive functionality, the Fluke 1621 Kit is a handy grounding tool for electrical contractors, utility test engineers, and earth ground specialists.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEasily capture values with single-button operation\u003c\/li\u003e\n\u003cli\u003e3-pole Fall-of-Potential earth testing for basic measurements\u003c\/li\u003e\n\u003cli\u003e2-pole resistance measurements for added versatility\u003c\/li\u003e\n\u003cli\u003eEnsure accurate measurements with automatic ‘noise’ voltage detection\u003c\/li\u003e\n\u003cli\u003eHazardous voltage warning offers increased user protection\u003c\/li\u003e\n\u003cli\u003eClearly read and record data with a large, backlit display\u003c\/li\u003e\n\u003cli\u003eRugged holster and design for tough work environments\u003c\/li\u003e\n\u003cli\u003ePortable size allows for easy transportation\u003c\/li\u003e\n\u003cli\u003eInstantly be alerted to measurements outside of your set limit, when you use the adjustable limit setting\u003c\/li\u003e\n\u003cli\u003e600 V Cat II\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring functions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3-pole earth ground resistance, 2-pole ac resistance of a conductor, Interference voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic error\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRefers to the reference temperature range and is guaranteed for one year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 measurements\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOne 9 volt alkaline (LR61)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery condition\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLO-BAT is displayed if voltage drops below 6.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVoltages\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eBetween jacks H\/C2 and E\/C1\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Veff maximum (effective voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBetween jacks S\/P2 and E\/C1\u003c\/td\u003e\n\u003ctd\u003e250 Veff maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClimatic class\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eVDE\/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4\/87)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eTemperature performance\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eWorking\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to +50°C (+14°F to +122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating\u003c\/td\u003e\n\u003ctd\u003e0°C to +35°C (+32°F to +95°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C (+68°F to +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003e+23°C ±2°C (+73°F ±4°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.1% of range per degree Kelvin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC\/EN 61010-1, 600 V CAT II, pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e113 x 54 x 216 mm (4.5 x 2.1 x 8.5 in), including holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e850 g (1.9 lb), including standard accessories, volume approximately 600 cm\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"10\"\u003eMaximum deviations\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eE\u003csub\u003e1\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eInfluence factor\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePosition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e1\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eDeviation influence\u003c\/td\u003e\n\u003ctd\u003e0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e2\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eInfluence factor\u003c\/td\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e2\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eDeviation influence\u003c\/td\u003e\n\u003ctd\u003e0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e3\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eInfluence factor\u003c\/td\u003e\n\u003ctd\u003eTemperature E\u003csub\u003e3\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e3\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eDeviation influence\u003c\/td\u003e\n\u003ctd\u003e2.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e4\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eInfluence factor\u003c\/td\u003e\n\u003ctd\u003eSerial interference voltage (20 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e4\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eDeviation influence\u003c\/td\u003e\n\u003ctd\u003e0.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e5\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eInfluence factor\u003c\/td\u003e\n\u003ctd\u003eProbe- and auxiliary probe resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e5\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eDeviation influence\u003c\/td\u003e\n\u003ctd\u003e10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.7 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 40; IEC\/EN 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eEmission\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61326 Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmunity\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61326 Annex C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eR\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eResistance measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasuring method\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent-voltage measurement with improved cross-talk attenuation, no compensation of measuring lead resistance, with probe (3-pole) or without probe (2-pole), as per IEC\/EN 61557–5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd\u003e23 to 24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum permissible overload\u003c\/td\u003e\n\u003ctd\u003e250 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 seconds (average from when START is pressed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLimit input\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTester retains set value even if instrument is turned off (assuming battery power supply is sufficient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eAutomatic changeover of resolution\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eR\u003csub\u003eH\u003c\/sub\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 7 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eInterference voltage display DC + AC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eVmax\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e30 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80 dB at 50 Hz and 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRi\u003c\/td\u003e\n\u003ctd\u003e680 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring uncertainty\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10% for pure AC and DC signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMeasuring Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e0.15 Ω to 20 Ω\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0 to 19.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e200 Ω\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e20 to 199.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e2 kΩ\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e200 to 1999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Uncertainty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(6% of measured value + 5D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating uncertainty IEC 61557\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(18% of measured value + 5D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003eFluke 1621 GEO Earth Ground Tester\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUsers manual\u003c\/li\u003e\n\u003cli\u003eTwo measuring leads with alligator clips, 2 m (6 ft)\u003c\/li\u003e\n\u003cli\u003eOne battery, 9 V alkaline (LR61)\u003c\/li\u003e\n\u003cli\u003eOne protective holster, yellow\u003c\/li\u003e\n\u003cli\u003eOne CD-ROM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFluke 1621 Kit\u003c\/p\u003e\n\u003cp\u003eIncludes everything the tester includes plus:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 cable reels with wire (1-50 m, 1-25 m)\u003c\/li\u003e\n\u003cli\u003e3 earth ground stakes\u003c\/li\u003e\n\u003cli\u003e1 Test lead (red and black 2 m)\u003c\/li\u003e\n\u003cli\u003eHard carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1621_Spec.PDF?1807\" target=\"_blank\" title=\"Fluke 1621 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1621 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e","published_at":"2018-03-07T15:03:45-07:00","created_at":"2018-03-07T15:05:56-07:00","vendor":"Fluke","type":"Earth Ground Testers","tags":[],"price":205500,"price_min":205500,"price_max":246600,"available":true,"price_varies":true,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":11043675078699,"title":"FLU-1621","option1":"FLU-1621","option2":null,"option3":null,"sku":"FLU-1621","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1621 GEO Earth Ground Tester - FLU-1621","public_title":"FLU-1621","options":["FLU-1621"],"price":205500,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":""},{"id":30265064783915,"title":"FLU-1621-KIT","option1":"FLU-1621-KIT","option2":null,"option3":null,"sku":"FLU-1621-KIT","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Fluke 1621 GEO Earth Ground Tester - FLU-1621-KIT","public_title":"FLU-1621-KIT","options":["FLU-1621-KIT"],"price":246600,"weight":4536,"compare_at_price":null,"inventory_management":"shopify","barcode":"0 95969 49446 5"}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/719fn_tY3oL._SL1500.jpg?v=1569514632","\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/4JNW2_AS01.jpg?v=1569514632"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/products\/719fn_tY3oL._SL1500.jpg?v=1569514632","options":["Model"],"content":"\u003cp\u003e\u003cspan\u003eThe Fluke 1621 is an easy-to-use earth ground tester. For ground resistance testing, the 1621 is the first line of defense in detecting reliable ground connections. The unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance tests. Its convenient size, rugged holster, and large, clear LCD display make it an ideal field earth ground tester, for most electrical grounding work environments. With a simple user interface and intuitive functionality, the Fluke 1621 is a handy grounding tool for electrical contractors, utility test engineers, and earth ground specialists.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 1621 Kit is an easy-to-use earth ground tester. For ground resistance testing, the 1621 Kit is the first line of defense in detecting reliable ground connections. The unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance tests. Its convenient size, rugged holster, and large, clear LCD display make it an ideal field earth ground tester, for most electrical grounding work environments. With a simple user interface and intuitive functionality, the Fluke 1621 Kit is a handy grounding tool for electrical contractors, utility test engineers, and earth ground specialists.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEasily capture values with single-button operation\u003c\/li\u003e\n\u003cli\u003e3-pole Fall-of-Potential earth testing for basic measurements\u003c\/li\u003e\n\u003cli\u003e2-pole resistance measurements for added versatility\u003c\/li\u003e\n\u003cli\u003eEnsure accurate measurements with automatic ‘noise’ voltage detection\u003c\/li\u003e\n\u003cli\u003eHazardous voltage warning offers increased user protection\u003c\/li\u003e\n\u003cli\u003eClearly read and record data with a large, backlit display\u003c\/li\u003e\n\u003cli\u003eRugged holster and design for tough work environments\u003c\/li\u003e\n\u003cli\u003ePortable size allows for easy transportation\u003c\/li\u003e\n\u003cli\u003eInstantly be alerted to measurements outside of your set limit, when you use the adjustable limit setting\u003c\/li\u003e\n\u003cli\u003e600 V Cat II\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring functions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3-pole earth ground resistance, 2-pole ac resistance of a conductor, Interference voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic error\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRefers to the reference temperature range and is guaranteed for one year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 measurements\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOne 9 volt alkaline (LR61)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery condition\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLO-BAT is displayed if voltage drops below 6.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVoltages\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eBetween jacks H\/C2 and E\/C1\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Veff maximum (effective voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBetween jacks S\/P2 and E\/C1\u003c\/td\u003e\n\u003ctd\u003e250 Veff maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClimatic class\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eVDE\/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4\/87)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eTemperature performance\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eWorking\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to +50°C (+14°F to +122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating\u003c\/td\u003e\n\u003ctd\u003e0°C to +35°C (+32°F to +95°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C (+68°F to +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003e+23°C ±2°C (+73°F ±4°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.1% of range per degree Kelvin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC\/EN 61010-1, 600 V CAT II, pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e113 x 54 x 216 mm (4.5 x 2.1 x 8.5 in), including holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e850 g (1.9 lb), including standard accessories, volume approximately 600 cm\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"10\"\u003eMaximum deviations\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eE\u003csub\u003e1\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eInfluence factor\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePosition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e1\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eDeviation influence\u003c\/td\u003e\n\u003ctd\u003e0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e2\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eInfluence factor\u003c\/td\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e2\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eDeviation influence\u003c\/td\u003e\n\u003ctd\u003e0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e3\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eInfluence factor\u003c\/td\u003e\n\u003ctd\u003eTemperature E\u003csub\u003e3\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e3\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eDeviation influence\u003c\/td\u003e\n\u003ctd\u003e2.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e4\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eInfluence factor\u003c\/td\u003e\n\u003ctd\u003eSerial interference voltage (20 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e4\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eDeviation influence\u003c\/td\u003e\n\u003ctd\u003e0.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e5\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eInfluence factor\u003c\/td\u003e\n\u003ctd\u003eProbe- and auxiliary probe resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e5\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eDeviation influence\u003c\/td\u003e\n\u003ctd\u003e10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.7 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 40; IEC\/EN 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eEmission\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61326 Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmunity\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61326 Annex C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eR\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eResistance measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasuring method\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent-voltage measurement with improved cross-talk attenuation, no compensation of measuring lead resistance, with probe (3-pole) or without probe (2-pole), as per IEC\/EN 61557–5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd\u003e23 to 24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum permissible overload\u003c\/td\u003e\n\u003ctd\u003e250 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 seconds (average from when START is pressed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLimit input\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTester retains set value even if instrument is turned off (assuming battery power supply is sufficient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eAutomatic changeover of resolution\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eR\u003csub\u003eH\u003c\/sub\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 7 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eInterference voltage display DC + AC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eVmax\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e30 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80 dB at 50 Hz and 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRi\u003c\/td\u003e\n\u003ctd\u003e680 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring uncertainty\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10% for pure AC and DC signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMeasuring Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e0.15 Ω to 20 Ω\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0 to 19.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e200 Ω\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e20 to 199.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e2 kΩ\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e200 to 1999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Uncertainty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(6% of measured value + 5D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating uncertainty IEC 61557\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(18% of measured value + 5D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003eFluke 1621 GEO Earth Ground Tester\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUsers manual\u003c\/li\u003e\n\u003cli\u003eTwo measuring leads with alligator clips, 2 m (6 ft)\u003c\/li\u003e\n\u003cli\u003eOne battery, 9 V alkaline (LR61)\u003c\/li\u003e\n\u003cli\u003eOne protective holster, yellow\u003c\/li\u003e\n\u003cli\u003eOne CD-ROM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFluke 1621 Kit\u003c\/p\u003e\n\u003cp\u003eIncludes everything the tester includes plus:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 cable reels with wire (1-50 m, 1-25 m)\u003c\/li\u003e\n\u003cli\u003e3 earth ground stakes\u003c\/li\u003e\n\u003cli\u003e1 Test lead (red and black 2 m)\u003c\/li\u003e\n\u003cli\u003eHard carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1621_Spec.PDF?1807\" target=\"_blank\" title=\"Fluke 1621 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1621 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e"}
Fluke 1621 GEO Earth Ground Tester

Fluke 1621 GEO Earth Ground Tester

$2,466.00 CAD

The Fluke 1621 is an easy-to-use earth ground tester. For ground resistance testing, the 1621 is the first line of defense in detecting reliable ground connections. The unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance tests. Its convenient size, rugged holster, and large, clear LCD...


More Info