{ "id":1076387610667, "title":"Fluke 1621 GEO Earth Ground Tester","handle":"fluke-1621-earth-ground-tester-kit", "description":"\u003cp\u003e\u003cspan\u003eThe Fluke 1621 is an easy-to-use earth ground tester. For ground resistance testing, the 1621 is the first line of defense in detecting reliable ground connections. The unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance tests. Its convenient size, rugged holster, and large, clear LCD display make it an ideal field earth ground tester, for most electrical grounding work environments. With a simple user interface and intuitive functionality, the Fluke 1621 is a handy grounding tool for electrical contractors, utility test engineers, and earth ground specialists.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe Fluke 1621 Kit is an easy-to-use earth ground tester. For ground resistance testing, the 1621 Kit is the first line of defense in detecting reliable ground connections. The unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance tests. Its convenient size, rugged holster, and large, clear LCD display make it an ideal field earth ground tester, for most electrical grounding work environments. With a simple user interface and intuitive functionality, the Fluke 1621 Kit is a handy grounding tool for electrical contractors, utility test engineers, and earth ground specialists.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEasily capture values with single-button operation\u003c\/li\u003e\n\u003cli\u003e3-pole Fall-of-Potential earth testing for basic measurements\u003c\/li\u003e\n\u003cli\u003e2-pole resistance measurements for added versatility\u003c\/li\u003e\n\u003cli\u003eEnsure accurate measurements with automatic ‘noise’ voltage detection\u003c\/li\u003e\n\u003cli\u003eHazardous voltage warning offers increased user protection\u003c\/li\u003e\n\u003cli\u003eClearly read and record data with a large, backlit display\u003c\/li\u003e\n\u003cli\u003eRugged holster and design for tough work environments\u003c\/li\u003e\n\u003cli\u003ePortable size allows for easy transportation\u003c\/li\u003e\n\u003cli\u003eInstantly be alerted to measurements outside of your set limit, when you use the adjustable limit setting\u003c\/li\u003e\n\u003cli\u003e600 V Cat II\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring functions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3-pole earth ground resistance, 2-pole ac resistance of a conductor, Interference voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic error\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eRefers to the reference temperature range and is guaranteed for one year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring rate\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 measurements\/second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003csup\u003e1\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eOne 9 volt alkaline (LR61)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery condition\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLO-BAT is displayed if voltage drops below 6.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eVoltages\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eBetween jacks H\/C2 and E\/C1\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Veff maximum (effective voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBetween jacks S\/P2 and E\/C1\u003c\/td\u003e\n\u003ctd\u003e250 Veff maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClimatic class\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eVDE\/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4\/87)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eTemperature performance\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eWorking\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to +50°C (+14°F to +122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating\u003c\/td\u003e\n\u003ctd\u003e0°C to +35°C (+32°F to +95°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C (+68°F to +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003e+23°C ±2°C (+73°F ±4°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficient\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±0.1% of range per degree Kelvin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIEC\/EN 61010-1, 600 V CAT II, pollution degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e113 x 54 x 216 mm (4.5 x 2.1 x 8.5 in), including holster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e850 g (1.9 lb), including standard accessories, volume approximately 600 cm\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eElectrical Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"10\"\u003eMaximum deviations\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eE\u003csub\u003e1\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eInfluence factor\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003ePosition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e1\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eDeviation influence\u003c\/td\u003e\n\u003ctd\u003e0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e2\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eInfluence factor\u003c\/td\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e2\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eDeviation influence\u003c\/td\u003e\n\u003ctd\u003e0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e3\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eInfluence factor\u003c\/td\u003e\n\u003ctd\u003eTemperature E\u003csub\u003e3\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e3\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eDeviation influence\u003c\/td\u003e\n\u003ctd\u003e2.3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e4\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eInfluence factor\u003c\/td\u003e\n\u003ctd\u003eSerial interference voltage (20 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e4\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eDeviation influence\u003c\/td\u003e\n\u003ctd\u003e0.6%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e5\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eInfluence factor\u003c\/td\u003e\n\u003ctd\u003eProbe- and auxiliary probe resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003csub\u003e5\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eDeviation influence\u003c\/td\u003e\n\u003ctd\u003e10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3.7 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection type\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP 40; IEC\/EN 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eElectromagnetic compatibility\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eEmission\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61326 Class B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmunity\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61326 Annex C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003eR\u003csub\u003eE\u003c\/sub\u003e\u003cspan\u003e \u003c\/span\u003eResistance measurement\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eMeasuring method\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent-voltage measurement with improved cross-talk attenuation, no compensation of measuring lead resistance, with probe (3-pole) or without probe (2-pole), as per IEC\/EN 61557–5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen circuit voltage\u003c\/td\u003e\n\u003ctd\u003e23 to 24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit current\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 mA AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring frequency\u003c\/td\u003e\n\u003ctd\u003e128 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum permissible overload\u003c\/td\u003e\n\u003ctd\u003e250 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 seconds (average from when START is pressed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLimit input\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTester retains set value even if instrument is turned off (assuming battery power supply is sufficient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eAutomatic changeover of resolution\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eR\u003csub\u003eH\u003c\/sub\u003e\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 7 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR\u003csub\u003eH\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 50 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eInterference voltage display DC + AC\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eVmax\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e30 Veff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80 dB at 50 Hz and 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRi\u003c\/td\u003e\n\u003ctd\u003e680 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring uncertainty\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10% for pure AC and DC signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"3\"\u003eMeasuring Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e0.15 Ω to 20 Ω\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e0 to 19.99 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e200 Ω\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e20 to 199.9 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e2 kΩ\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eResolution\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e1 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay range\u003c\/td\u003e\n\u003ctd\u003e200 to 1999 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Uncertainty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(6% of measured value + 5D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating uncertainty IEC 61557\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±(18% of measured value + 5D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cdiv class=\"accordion active\"\u003e\n\u003cdiv class=\"model-desc\" itemprop=\"description\"\u003eFluke 1621 GEO Earth Ground Tester\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"panel model-details\"\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUsers manual\u003c\/li\u003e\n\u003cli\u003eTwo measuring leads with alligator clips, 2 m (6 ft)\u003c\/li\u003e\n\u003cli\u003eOne battery, 9 V alkaline (LR61)\u003c\/li\u003e\n\u003cli\u003eOne protective holster, yellow\u003c\/li\u003e\n\u003cli\u003eOne CD-ROM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFluke 1621 Kit\u003c\/p\u003e\n\u003cp\u003eIncludes everything the tester includes plus:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2 cable reels with wire (1-50 m, 1-25 m)\u003c\/li\u003e\n\u003cli\u003e3 earth ground stakes\u003c\/li\u003e\n\u003cli\u003e1 Test lead (red and black 2 m)\u003c\/li\u003e\n\u003cli\u003eHard carrying case\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1621_Spec.PDF?1807\" target=\"_blank\" title=\"Fluke 1621 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1621 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-03-07T15:03:45", "created_at":"2018-03-07T15:05:56", "vendor":"Fluke", "type":"Earth Ground Testers", "tags":[], "price":205500, "price_min":205500, "price_max":246600, "price_varies":true, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[11043675078699,30265064783915], "variants":[{ "id":11043675078699, "product_id":1076387610667, "product_handle":"fluke-1621-earth-ground-tester-kit", "title":"FLU-1621", "option1":"FLU-1621", "option2":null, "option3":null, "sku":"FLU-1621", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 1621 GEO Earth Ground Tester - FLU-1621", "options":["FLU-1621"], "price":205500, "weight":4536, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":""},{ "id":30265064783915, "product_id":1076387610667, "product_handle":"fluke-1621-earth-ground-tester-kit", "title":"FLU-1621-KIT", "option1":"FLU-1621-KIT", "option2":null, "option3":null, "sku":"FLU-1621-KIT", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 1621 GEO Earth Ground Tester - FLU-1621-KIT", "options":["FLU-1621-KIT"], "price":246600, "weight":4536, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969494465"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/719fn_tY3oL._SL1500.jpg?v=1569514632","\/\/kingswayinstruments.com\/cdn\/shop\/products\/4JNW2_AS01.jpg?v=1569514632"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/719fn_tY3oL._SL1500.jpg?v=1569514632", "options":["Model"], "url":"\/products\/fluke-1621-earth-ground-tester-kit"}

Fluke 1621 GEO Earth Ground Tester

Product Description

The Fluke 1621 is an easy-to-use earth ground tester. For ground resistance testing, the 1621 is the first line of defense in detecting reliable ground connections. The unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance tests. Its convenient size, rugged holster, and large, clear LCD display make it an ideal field earth ground tester, for most electrical grounding work environments. With a simple user interface and intuitive functionality, the Fluke 1621 is a handy grounding tool for electrical contractors, utility test engineers, and earth ground specialists.

The Fluke 1621 Kit is an easy-to-use earth ground tester. For ground resistance testing, the 1621 Kit is the first line of defense in detecting reliable ground connections. The unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance tests. Its convenient size, rugged holster, and large, clear LCD display make it an ideal field earth ground tester, for most electrical grounding work environments. With a simple user interface and intuitive functionality, the Fluke 1621 Kit is a handy grounding tool for electrical contractors, utility test engineers, and earth ground specialists.

Sku: FLU-1621
Vendor: Fluke
On Back-Order
$2,466.00 CAD

  • Easily capture values with single-button operation
  • 3-pole Fall-of-Potential earth testing for basic measurements
  • 2-pole resistance measurements for added versatility
  • Ensure accurate measurements with automatic ‘noise’ voltage detection
  • Hazardous voltage warning offers increased user protection
  • Clearly read and record data with a large, backlit display
  • Rugged holster and design for tough work environments
  • Portable size allows for easy transportation
  • Instantly be alerted to measurements outside of your set limit, when you use the adjustable limit setting
  • 600 V Cat II
General Specifications
Measuring functions 3-pole earth ground resistance, 2-pole ac resistance of a conductor, Interference voltage
Intrinsic error Refers to the reference temperature range and is guaranteed for one year
Measuring rate 2 measurements/second
Battery1 One 9 volt alkaline (LR61)
Battery condition LO-BAT is displayed if voltage drops below 6.5 V
Voltages Between jacks H/C2 and E/C1 250 Veff maximum (effective voltage)
Between jacks S/P2 and E/C1 250 Veff maximum
Climatic class VDE/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4/87)
Temperature performance2 Working -10°C to +50°C (+14°F to +122°F)
Operating 0°C to +35°C (+32°F to +95°F)
Storage -20°C to +60°C (+68°F to +140°F)
Reference +23°C ±2°C (+73°F ±4°F)
Temperature coefficient ±0.1% of range per degree Kelvin
Safety IEC/EN 61010-1, 600 V CAT II, pollution degree 2
Dimensions 113 x 54 x 216 mm (4.5 x 2.1 x 8.5 in), including holster
Weight 850 g (1.9 lb), including standard accessories, volume approximately 600 cm3
Electrical Specifications
Maximum deviations E1 Influence factor Position
E1 Deviation influence 0%
E2 Influence factor Supply voltage
E2 Deviation influence 0%
E3 Influence factor Temperature E3
E3 Deviation influence 2.3%
E4 Influence factor Serial interference voltage (20 V)
E4 Deviation influence 0.6%
E5 Influence factor Probe- and auxiliary probe resistance
E5 Deviation influence 10%
Test voltage 3.7 kV
Protection type IP 40; IEC/EN 60529
Electromagnetic compatibility Emission IEC/EN 61326 Class B
Immunity IEC/EN 61326 Annex C
RE Resistance measurement Measuring method Current-voltage measurement with improved cross-talk attenuation, no compensation of measuring lead resistance, with probe (3-pole) or without probe (2-pole), as per IEC/EN 61557–5
Open circuit voltage 23 to 24 V AC
Short circuit current > 50 mA AC
Measuring frequency 128 Hz
Maximum permissible overload 250 Veff
Measuring time 8 seconds (average from when START is pressed)
Limit input Tester retains set value even if instrument is turned off (assuming battery power supply is sufficient)
Automatic changeover of resolution RH < 7 kΩ
Resolution 0.01 Ω
RH < 50 kΩ
Resolution 0.1 Ω
RH > 50 kΩ
Resolution 1 Ω
Interference voltage display DC + AC Vmax 30 Veff
Common mode rejection > 80 dB at 50 Hz and 60 Hz
Ri 680 kΩ
Measuring uncertainty < 10% for pure AC and DC signals
Measuring Range
0.15 Ω to 20 Ω Resolution 0.01 Ω
Display range 0 to 19.99 Ω
200 Ω Resolution 0.1 Ω
Display range 20 to 199.9 Ω
2 kΩ Resolution 1 Ω
Display range 200 to 1999 Ω
Intrinsic Uncertainty ±(6% of measured value + 5D)
Operating uncertainty IEC 615573 ±(18% of measured value + 5D)


Fluke 1621 GEO Earth Ground Tester

Includes:

  • Users manual
  • Two measuring leads with alligator clips, 2 m (6 ft)
  • One battery, 9 V alkaline (LR61)
  • One protective holster, yellow
  • One CD-ROM

Fluke 1621 Kit

Includes everything the tester includes plus:

  • 2 cable reels with wire (1-50 m, 1-25 m)
  • 3 earth ground stakes
  • 1 Test lead (red and black 2 m)
  • Hard carrying case

Related Products