{ "id":1839589490731, "title":"Fluke 1630-2 FC Earth Ground Clamp","handle":"fluke-1630-2-fc-earth-ground-clamp", "description":"\u003cp\u003eTest the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes. Stay on line—identify ground loop resistance without the need to disconnect then reconnect the earth electrode from the system.\u003c\/p\u003e\n\u003cp\u003eThe Fluke 1630-2 FC Stakeless Earth Ground Clamp is the kind of high-quality, rugged tool you expect from Fluke. Heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eStakeless measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1630-2 FC clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes. You can also perform ground tests in places that were previously difficult: inside buildings, on power pylons or anywhere you don't have access to soil to place auxiliary test stakes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFluke Connect\u003csup\u003e®\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003eWireless System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1630-2 FC supports the Fluke Connect Wireless System (may not be available in all regions). Fluke Connect wirelessly connects the clamp with an app on your smartphone or tablet. The app shows the ground resistance measurements on your smartphone or tablet display. You can save these measurements, GPS location from your phone and images to Fluke Connect Cloud storage and share with your team.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eEarth ground ac leakage current measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIdentify ac leakage currents without disconnecting the earth ground stake from the grounding system–ideal for system troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRugged\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHeavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLogging measurements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe earth ground clamp saves time by automatically recording data at pre-set intervals and saves up to 32,760 measurements in memory at the set logging interval. Saves time by recording and storing measured values.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm threshold\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUser-defined high\/low alarm limits, for rapid measurement evaluation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBand-pass filter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSelectable band-pass filter function removes unwanted noise from the ac leakage current measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"3\" style=\"height: 21px;\"\u003e\u003cstrong\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eMaximum voltage to earth ground\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003e1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eBattery type\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003eAA alkaline IEC\/EN LR6 (x4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eBattery life\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003eMore than 15 hours*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"3\" style=\"height: 21px;\"\u003e\u003csmall\u003e* In Ground Resistance measurement mode, with backlight turned off, and RF mode turned off\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003e40 Hz to 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eIngress protection\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003eIEC\/EN 60529: IP30 with jaw closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd rowspan=\"2\" style=\"height: 42px;\"\u003eLCD\u003c\/td\u003e\n\u003ctd style=\"height: 21px;\"\u003eDigital reading\u003c\/td\u003e\n\u003ctd style=\"height: 21px;\"\u003e9999 counts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eRefresh rate\u003c\/td\u003e\n\u003ctd style=\"height: 21px;\"\u003e4 per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"height: 21px;\"\u003e-10 °C to + 50 °C\u003c\/td\u003e\n\u003ctd style=\"height: 21px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"height: 21px;\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" style=\"height: 21px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEarth Ground clamp\u003c\/li\u003e\n\u003cli\u003eHard case\u003c\/li\u003e\n\u003cli\u003eLoop resistance standard\u003c\/li\u003e\n\u003cli\u003e4 AA batteries\u003c\/li\u003e\n\u003cli\u003eSafety information guide\u003c\/li\u003e\n\u003cli\u003eQuick reference guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_1630-2FC_Earth_Ground_Clamp_Spec.PDF?1681\" target=\"_blank\" title=\"Fluke 1630-2 FC Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 1630-2 FC Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2019-07-25T10:21:50", "created_at":"2019-07-25T10:27:10", "vendor":"Fluke", "type":"Earth Ground Testers", "tags":[], "price":353599, "price_min":353599, "price_max":353599, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[16804038049835], "variants":[{ "id":16804038049835, "product_id":1839589490731, "product_handle":"fluke-1630-2-fc-earth-ground-clamp", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"FLU-1630-2FC", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 1630-2 FC Earth Ground Clamp - Default Title", "options":["Default Title"], "price":353599, "weight":2268, "compare_at_price":null, "inventory_quantity":2, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":2, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969831185"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1630-2.jpg?v=1564072033"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/fluke-1630-2.jpg?v=1564072033", "options":["Title"], "url":"\/products\/fluke-1630-2-fc-earth-ground-clamp"}

Fluke 1630-2 FC Earth Ground Clamp

Product Description

Test the grounding components of equipment in hard-to-reach spaces, including areas that are indoors or fully paved and do not permit driving auxiliary test stakes. Stay on line—identify ground loop resistance without the need to disconnect then reconnect the earth electrode from the system.

The Fluke 1630-2 FC Stakeless Earth Ground Clamp is the kind of high-quality, rugged tool you expect from Fluke. Heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments.

 

Sku: FLU-1630-2FC
Vendor: Fluke
2 left in stock.
$3,535.99 CAD
Maximum quantity available reached.

Stakeless measurement

The 1630-2 FC clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes. You can also perform ground tests in places that were previously difficult: inside buildings, on power pylons or anywhere you don't have access to soil to place auxiliary test stakes.

Fluke Connect® Wireless System

The 1630-2 FC supports the Fluke Connect Wireless System (may not be available in all regions). Fluke Connect wirelessly connects the clamp with an app on your smartphone or tablet. The app shows the ground resistance measurements on your smartphone or tablet display. You can save these measurements, GPS location from your phone and images to Fluke Connect Cloud storage and share with your team.

Earth ground ac leakage current measurement

Identify ac leakage currents without disconnecting the earth ground stake from the grounding system–ideal for system troubleshooting.

Rugged

Heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments.

Logging measurements

The earth ground clamp saves time by automatically recording data at pre-set intervals and saves up to 32,760 measurements in memory at the set logging interval. Saves time by recording and storing measured values.

Alarm threshold

User-defined high/low alarm limits, for rapid measurement evaluation.

Band-pass filter

Selectable band-pass filter function removes unwanted noise from the ac leakage current measurement.

Electrical Specifications
Maximum voltage to earth ground 1000 V
Battery type AA alkaline IEC/EN LR6 (x4)
Battery life More than 15 hours*
* In Ground Resistance measurement mode, with backlight turned off, and RF mode turned off
Frequency range 40 Hz to 1 kHz
Ingress protection IEC/EN 60529: IP30 with jaw closed
LCD Digital reading 9999 counts
Refresh rate 4 per second
Operating temperature -10 °C to + 50 °C


  • Earth Ground clamp
  • Hard case
  • Loop resistance standard
  • 4 AA batteries
  • Safety information guide
  • Quick reference guide