{ "id":1072471015467, "title":"Fluke 561 HVAC Infrared \u0026 Contact Thermometer","handle":"fluke-561-infrared-and-contact-thermometer", "description":"\u003cp\u003eThe Fluke 561 IR contact thermometer combines the temperature measurement functions that industrial, electrical, and HVAC\/R professionals need in one tool. It is an IR thermometer for non-contact measurements, with K-type thermocouple capability for contact temperature measurement. It's fast, efficient, and easy to use, saving you valuable time and effort.\u003c\/p\u003e\n\u003cp\u003eUse the 561 IR capabilities to scan large areas or small objects quickly and efficiently, without having to shut down equipment. Measure hot, moving, electrically energized, and hard-to-reach objects instantly. Check motors, insulation, breakers, radiant heating, pipes, corroded connections, and wires. Plus, scan ducts, and other hard-to-reach objects from the floor and leave your ladder in the truck.\u003c\/p\u003e\n\u003cp\u003eYou can also use the Fluke 561's handy flexible pipe probe (included) to take super-heat or internal temperatures. Or plug in any industry standard type K mini connector thermocouple probe to take those measurements and preserve your investment in thermocouples you already own.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eContact and non-contact IR thermometer for measuring up close or at a distance, without a ladder\u003c\/li\u003e\n\u003cli\u003eMeasures temperature from -40°C to 550° C (-40°F to 1022°F)\u003c\/li\u003e\n\u003cli\u003eWorks with all standard mini-connector type K thermocouples\u003c\/li\u003e\n\u003cli\u003eProvides single-point laser sighting\u003c\/li\u003e\n\u003cli\u003eAllows easy emissivity adjustment for measuring pipes and other shiny surfaces more accurately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 550°C (-40 to 1022°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F) of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD:S (distance to spot size)\u003c\/td\u003e\n\u003ctd\u003e12:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eEasy emissivity selector\u003c\/td\u003e\n\u003ctd\u003eAdjustable with three settings:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003eLow (0.3), medium (0.7). high (0.95)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay accuracy [assumes ambient operating temperature of 23°C (73°F) to 25°C (77°F)]\u003c\/td\u003e\n\u003ctd\u003e±1.0% of reading ±1% of reading or ±1°C (±2°F), whichever is greater below 0°C \/ 32°F, ±1°C (±2°F) ±0.1°\/1°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e500 mSec (95% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e±0.5% of reading or ±1°C (±2°F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral response\u003c\/td\u003e\n\u003ctd\u003e8 µm to 14 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser sighting\u003c\/td\u003e\n\u003ctd\u003eSingle point laser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser shutoff\u003c\/td\u003e\n\u003ctd\u003eLaser turns off above ambient temperature of 40°C (104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser power\u003c\/td\u003e\n\u003ctd\u003eClass 2(II) operation; Output \u0026lt; 1 mW, wavelength 630-670 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 90% RH non-condensing, at \u0026lt; 30°C (86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower, battery life\u003c\/td\u003e\n\u003ctd\u003e2 AA batteries (alkaline or NiCD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay hold\u003c\/td\u003e\n\u003ctd\u003e7 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklit display\u003c\/td\u003e\n\u003ctd\u003eYes, LCD with dual temperatures (current and MAX\/MIN\/DIF\/KTC), low battery, F\/C indicator, and Scan\/Hold options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C (32°F to 120°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 65°C (-25°F to 150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAX, MIN, DIF temperatures\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Type K mini adapter input\u003c\/td\u003e\n\u003ctd\u003eYes, compatible with industry standard K type probes with mini-connector. Displays to the thermometer temperature range.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Type K fabric hook-and-loop fastener pipe probe\u003c\/td\u003e\n\u003ctd\u003eYes, with a temperature range of 0°C to 100°C (32°F to 212°F) and accuracy of ±2.2°C (±4°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHVAC measurement guide\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eK-Type thermocouple\u003c\/li\u003e\n\u003cli\u003eFabric hook-and-loop fastener pipe probe\u003c\/li\u003e\n\u003cli\u003eHard carrying case\u003c\/li\u003e\n\u003cli\u003e2 AA batteries\u003c\/li\u003e\n\u003cli\u003eUsers manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_561_Spec.PDF?1835\" target=\"_blank\" title=\"Fluke 561 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 561 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-03-06T16:11:52", "created_at":"2018-03-06T16:21:53", "vendor":"Fluke", "type":"Infrared Thermometers", "tags":[], "price":41479, "price_min":41479, "price_max":41479, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[11020190318635], "variants":[{ "id":11020190318635, "product_id":1072471015467, "product_handle":"fluke-561-infrared-and-contact-thermometer", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"FLU-561", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 561 HVAC Infrared \u0026 Contact Thermometer - Default Title", "options":["Default Title"], "price":41479, "weight":2268, "compare_at_price":null, "inventory_quantity":10, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":10, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969332538"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke-561-1.jpg?v=1570052674"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/Fluke-561-1.jpg?v=1570052674", "options":["Title"], "url":"\/products\/fluke-561-infrared-and-contact-thermometer"}

Fluke 561 HVAC Infrared & Contact Thermometer

Product Description

The Fluke 561 IR contact thermometer combines the temperature measurement functions that industrial, electrical, and HVAC/R professionals need in one tool. It is an IR thermometer for non-contact measurements, with K-type thermocouple capability for contact temperature measurement. It's fast, efficient, and easy to use, saving you valuable time and effort.

Use the 561 IR capabilities to scan large areas or small objects quickly and efficiently, without having to shut down equipment. Measure hot, moving, electrically energized, and hard-to-reach objects instantly. Check motors, insulation, breakers, radiant heating, pipes, corroded connections, and wires. Plus, scan ducts, and other hard-to-reach objects from the floor and leave your ladder in the truck.

You can also use the Fluke 561's handy flexible pipe probe (included) to take super-heat or internal temperatures. Or plug in any industry standard type K mini connector thermocouple probe to take those measurements and preserve your investment in thermocouples you already own.

Sku: FLU-561
Vendor: Fluke
10 left in stock.
$414.79 CAD
Maximum quantity available reached.

  • Contact and non-contact IR thermometer for measuring up close or at a distance, without a ladder
  • Measures temperature from -40°C to 550° C (-40°F to 1022°F)
  • Works with all standard mini-connector type K thermocouples
  • Provides single-point laser sighting
  • Allows easy emissivity adjustment for measuring pipes and other shiny surfaces more accurately.
General Specifications
Temperature -40 to 550°C (-40 to 1022°F)
Display resolution 0.1°C (0.1°F) of reading
D:S (distance to spot size) 12:1
Easy emissivity selector Adjustable with three settings:
Low (0.3), medium (0.7). high (0.95)
Display accuracy [assumes ambient operating temperature of 23°C (73°F) to 25°C (77°F)] ±1.0% of reading ±1% of reading or ±1°C (±2°F), whichever is greater below 0°C / 32°F, ±1°C (±2°F) ±0.1°/1°
Response time 500 mSec (95% of reading)
Repeatability ±0.5% of reading or ±1°C (±2°F), whichever is greater
Spectral response 8 µm to 14 µm
Laser sighting Single point laser
Laser shutoff Laser turns off above ambient temperature of 40°C (104°F)
Laser power Class 2(II) operation; Output < 1 mW, wavelength 630-670 nm
Relative humidity 10% to 90% RH non-condensing, at < 30°C (86°F)
Power, battery life 2 AA batteries (alkaline or NiCD)
Battery life 12 hours
Display hold 7 seconds
Backlit display Yes, LCD with dual temperatures (current and MAX/MIN/DIF/KTC), low battery, F/C indicator, and Scan/Hold options
Warranty 2 years
Operating temperature 0°C to 50°C (32°F to 120°F)
Storage temperature -20°C to 65°C (-25°F to 150°F)
MAX, MIN, DIF temperatures Yes
Thermocouple Type K mini adapter input Yes, compatible with industry standard K type probes with mini-connector. Displays to the thermometer temperature range.
Thermocouple Type K fabric hook-and-loop fastener pipe probe Yes, with a temperature range of 0°C to 100°C (32°F to 212°F) and accuracy of ±2.2°C (±4°F)
HVAC measurement guide Yes


Includes:

  • K-Type thermocouple
  • Fabric hook-and-loop fastener pipe probe
  • Hard carrying case
  • 2 AA batteries
  • Users manual

Related Products