{ "id":1069115408427, "title":"Fluke 566 Thermal Gun Infrared \u0026 Contact Thermometer","handle":"fluke-566-infrared-and-contact-thermometer", "description":"\u003cp\u003e\u003cspan\u003eThe 566 IR and contact thermometer features a simple, three-button, on-screen menu interface (in 6 languages) to make it easier than ever to measure temperature. You can quickly navigate advanced features to adjust emissivity, start data logging, or turn alarms on and off with just a few pushes of a button. And with its rugged, easy-to-use, ergonomic design, the Fluke 566 can stand up to tough industrial, electrical, and mechanical environments. These tools go beyond other IR thermometers (or pyrometers), helping you work more efficiently in more applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTwo-in-one IR and contact thermometer with a 30:1 distance-to-spot ratio\u003c\/li\u003e\n\u003cli\u003eMeasures temperatures from -40°C to 650°C (40°F to 1202°F)\u003c\/li\u003e\n\u003cli\u003eMakes it easy to access advanced features with the soft-key buttons and graphical display\u003c\/li\u003e\n\u003cli\u003eFeatures rugged, ergonomic design that stands up to tough industrial, electrical, and mechanical environments\u003c\/li\u003e\n\u003cli\u003eWorks with most K-type thermocouples\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eProduct Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared temperature range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 650°C (-40°F to 1202°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eInfrared accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt; 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°\/1°C or°F);\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\" colspan=\"2\"\u003e\u0026gt; 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared spectral response\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e8 µm to 14 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared response time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt; 500 msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Type-K input temperature range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-270°C to 1372°C (-454°F to 2501°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eThermocouple Type-K input accuracy\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e-270°C to -40°C\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e±(1°C + 0.2°\/1°C) (-454°F to -40°F: ±(2°F + 0.2°\/1°F))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-40°C to 1372°C\u003c\/td\u003e\n\u003ctd\u003e±1% or 1°C (-40°F to 2501°F: ±1% or 2°F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD:S (distance to measurement spot size)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser sighting\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSingle-point laser \u0026lt; 1 mw output Class 2 (II) operation, 630 nm to 670 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum spot size\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e19 mm (0.75 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissivity adjustment\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eBy built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData storage with date\/time stamp\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC interface and cable\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHi\/Low alarms\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAudible and two-color visual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin\/Max\/Avg\/Dif\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDot matrix 98 x 96 pixels with function menus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTwo levels, normal and extra bright for darker environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger lock\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchable Celsius and Fahrenheit\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 AA\/LR6 Batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003eIf used continuously\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003eLaser and backlight on, 12 hours; laser and backlight off, 100 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C to 60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBead thermocouple Type-K range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°C to 260°C (-40°F to 500°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBead thermocouple Type-K accuracy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e±1.1°C (2.0°F) from 0°C to 260°C (32°F to 500°F),\u003cbr\u003etypically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThermocouple K bead probe\u003c\/li\u003e\n\u003cli\u003eDurable hard case\u003c\/li\u003e\n\u003cli\u003e2 AA batteries\u003c\/li\u003e\n\u003cli\u003eGetting Started guide in 6 languages\u003c\/li\u003e\n\u003cli\u003eUser’s Manual on CD in 6 languages (English, Spanish, French, German, Portuguese, and Simplified Chinese)\u003c\/li\u003e\n\u003cli\u003e2-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_566_568DataSheet.pdf?1836\" target=\"_blank\" title=\"Fluke 566 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 566 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-03-05T15:34:12", "created_at":"2018-03-05T15:35:36", "vendor":"Fluke", "type":"Infrared Thermometers", "tags":[], "price":72759, "price_min":72759, "price_max":72759, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[11001177636907], "variants":[{ "id":11001177636907, "product_id":1069115408427, "product_handle":"fluke-566-infrared-and-contact-thermometer", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"FLU-566", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 566 Thermal Gun Infrared \u0026 Contact Thermometer - Default Title", "options":["Default Title"], "price":72759, "weight":2268, "compare_at_price":null, "inventory_quantity":1, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":1, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969400367"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/61hJ0Lv-kML._SL1500.jpg?v=1570052968","\/\/kingswayinstruments.com\/cdn\/shop\/products\/71VLb93kWCL._SL1500.jpg?v=1570052968","\/\/kingswayinstruments.com\/cdn\/shop\/products\/20151023163319VPFH9CSTJNF03_full.jpg?v=1570052968"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/61hJ0Lv-kML._SL1500.jpg?v=1570052968", "options":["Title"], "url":"\/products\/fluke-566-infrared-and-contact-thermometer"}

Fluke 566 Thermal Gun Infrared & Contact Thermometer

Product Description

The 566 IR and contact thermometer features a simple, three-button, on-screen menu interface (in 6 languages) to make it easier than ever to measure temperature. You can quickly navigate advanced features to adjust emissivity, start data logging, or turn alarms on and off with just a few pushes of a button. And with its rugged, easy-to-use, ergonomic design, the Fluke 566 can stand up to tough industrial, electrical, and mechanical environments. These tools go beyond other IR thermometers (or pyrometers), helping you work more efficiently in more applications.

Sku: FLU-566
Vendor: Fluke
1 left in stock.
$727.59 CAD
Maximum quantity available reached.

  • Two-in-one IR and contact thermometer with a 30:1 distance-to-spot ratio
  • Measures temperatures from -40°C to 650°C (40°F to 1202°F)
  • Makes it easy to access advanced features with the soft-key buttons and graphical display
  • Features rugged, ergonomic design that stands up to tough industrial, electrical, and mechanical environments
  • Works with most K-type thermocouples
Product Specifications
Infrared temperature range -40°C to 650°C (-40°F to 1202°F)
Infrared accuracy < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F);
> 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater
Display resolution 0.1°C / 0.1°F
Infrared spectral response 8 µm to 14 µm
Infrared response time < 500 msec
Thermocouple Type-K input temperature range -270°C to 1372°C (-454°F to 2501°F)
Thermocouple Type-K input accuracy -270°C to -40°C ±(1°C + 0.2°/1°C) (-454°F to -40°F: ±(2°F + 0.2°/1°F))
-40°C to 1372°C ±1% or 1°C (-40°F to 2501°F: ±1% or 2°F), whichever is greater
D:S (distance to measurement spot size) 30:1
Laser sighting Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm
Minimum spot size 19 mm (0.75 in)
Emissivity adjustment By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage with date/time stamp 20 points
PC interface and cable None
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Display Dot matrix 98 x 96 pixels with function menus
Backlight Two levels, normal and extra bright for darker environments
Trigger lock Yes
Switchable Celsius and Fahrenheit Yes
Power 2 AA/LR6 Batteries
Battery life If used continuously Laser and backlight on, 12 hours; laser and backlight off, 100 hours
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-40°F to 140°F)
Bead thermocouple Type-K range -40°C to 260°C (-40°F to 500°F)
Bead thermocouple Type-K accuracy ±1.1°C (2.0°F) from 0°C to 260°C (32°F to 500°F),
typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)


Includes:

  • Thermocouple K bead probe
  • Durable hard case
  • 2 AA batteries
  • Getting Started guide in 6 languages
  • User’s Manual on CD in 6 languages (English, Spanish, French, German, Portuguese, and Simplified Chinese)
  • 2-year warranty

Related Products