{ "id":1078609510443, "title":"Fluke 568 Ex Intrinsically Safe Mini Infrared Thermometer","handle":"fluke-568-ex-intrinsically-safe-infrared-thermometer", "description":"\u003cp\u003e\u003cstrong\u003eUse the Fluke 568 Ex for intrinsically safe temperature measurements anywhere in the world\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 568 Ex Intrinsically Safe Infrared Thermometer is certified by major rating bodies for use in Class I Div. 1 and Div. 2 or Zone 1 and 2 hazardous environments anywhere in the world. Whether you work in petroleum, chemical, oil and gas, or pharmaceutical environments, the 568 Ex allows you to carry the most trusted name in test tools into most Ex-rated areas around the globe. The simple, three-button on-screen menu interface is quick to use and makes even complex measurements easy. It takes just a few pushes of a button to adjust emissivity, record data, or turn on and off alarms. The 50:1 distance-to-spot ratio allows you to measure smaller objects from further away. And it also is compatible with K-type probes for contact measurements. Either way, you can count on the rugged, ergonomic design to stand up to tough conditions.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically safe infrared and contact thermometer\u003c\/li\u003e\n\u003cli\u003eMeets intrinsically safe certifications in Class I Div. 1 and Div. 2 or Zone 1 and 2 hazardous environments\u003c\/li\u003e\n\u003cli\u003eMeasures temperatures from -40°C to 800°C (-40°F to 1472°F)\u003c\/li\u003e\n\u003cli\u003eComes with a conductive case to safely carry the IR thermometer into hazardous areas\u003c\/li\u003e\n\u003cli\u003eOffers a distance-to-spot ratio of 50:1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eSpecifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared temperature range\u003c\/td\u003e\n\u003ctd\u003e-40°C to 800°C (-40°F to 1472°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared accuracy\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°\/1°C or°F);\u003cbr\u003e\u0026gt; 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared spectral response\u003c\/td\u003e\n\u003ctd\u003e8 µm to 14 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared response time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple type-k input temperature range\u003c\/td\u003e\n\u003ctd\u003e-270°C to 1372°C (-454°F to 2501°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple type-k input accuracy\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; -40°C: ±(1°C + 0.2°\/1°C)\u003cbr\u003e≥ -40°C: ±1% or 1°C, whichever is greater \u0026lt; -40°F: ±(2°F + 0.2°\/1°F)\u003cbr\u003e≥ -40°F: ±1% or 2°F, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD:S (distance to measurement spot size)\u003c\/td\u003e\n\u003ctd\u003e50:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser sighting\u003c\/td\u003e\n\u003ctd\u003eSingle-point laser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum spot size\u003c\/td\u003e\n\u003ctd\u003e19 mm (0.75 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissivity adjustment\u003c\/td\u003e\n\u003ctd\u003eBy built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData storage\u003c\/td\u003e\n\u003ctd\u003e99 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHi\/Low alarms\u003c\/td\u003e\n\u003ctd\u003eAudible and two-color visual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin\/Max\/Avg\/Dif\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDot matrix with function menus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eTwo levels, normal and extra bright for darker environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger lock\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchable celsius and fahrenheit\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e2 AAA\/LR03 type-approved batteries (For a list of type-approved batteries, refer to Product Safety Instructions.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e4 hours with laser and backlight on;\u003cbr\u003e100 hours with laser and backlight off, at 100% duty cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 60°C (-40°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBead thermocouple type-k range\u003c\/td\u003e\n\u003ctd\u003e-40°C to 260°C (-40°F to 500°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBead thermocouple type-k accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.1°C (2.0°F) from 0°C to 260°C (32 °F to 500°F),\u003cbr\u003etypically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eK-type thermocouple bead probe\u003c\/li\u003e\n\u003cli\u003eConductive IS hard carrying case\u003c\/li\u003e\n\u003cli\u003eUser’s manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_568EX_Spec.PDF?1837\" target=\"_blank\" title=\"Fluke 568 Ex Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 568 Ex Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-03-08T09:15:10", "created_at":"2018-03-08T09:19:34", "vendor":"Fluke", "type":"Infrared Thermometers", "tags":[], "price":330479, "price_min":330479, "price_max":330479, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[11059293454379], "variants":[{ "id":11059293454379, "product_id":1078609510443, "product_handle":"fluke-568-ex-intrinsically-safe-infrared-thermometer", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"FLU-568EX\/ELT", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 568 Ex Intrinsically Safe Mini Infrared Thermometer - Default Title", "options":["Default Title"], "price":330479, "weight":2268, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969666121"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/FLU4321655.jpg?v=1520525976","\/\/kingswayinstruments.com\/cdn\/shop\/products\/FLUKE_568Ex_PRODUCT-02.png?v=1520525977"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/FLU4321655.jpg?v=1520525976", "options":["Title"], "url":"\/products\/fluke-568-ex-intrinsically-safe-infrared-thermometer"}

Fluke 568 Ex Intrinsically Safe Mini Infrared Thermometer

Product Description

Use the Fluke 568 Ex for intrinsically safe temperature measurements anywhere in the world

The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is certified by major rating bodies for use in Class I Div. 1 and Div. 2 or Zone 1 and 2 hazardous environments anywhere in the world. Whether you work in petroleum, chemical, oil and gas, or pharmaceutical environments, the 568 Ex allows you to carry the most trusted name in test tools into most Ex-rated areas around the globe. The simple, three-button on-screen menu interface is quick to use and makes even complex measurements easy. It takes just a few pushes of a button to adjust emissivity, record data, or turn on and off alarms. The 50:1 distance-to-spot ratio allows you to measure smaller objects from further away. And it also is compatible with K-type probes for contact measurements. Either way, you can count on the rugged, ergonomic design to stand up to tough conditions.

Sku: FLU-568EX/ELT
Vendor: Fluke
On Back-Order
$3,304.79 CAD

  • Intrinsically safe infrared and contact thermometer
  • Meets intrinsically safe certifications in Class I Div. 1 and Div. 2 or Zone 1 and 2 hazardous environments
  • Measures temperatures from -40°C to 800°C (-40°F to 1472°F)
  • Comes with a conductive case to safely carry the IR thermometer into hazardous areas
  • Offers a distance-to-spot ratio of 50:1
Specifications
Infrared temperature range -40°C to 800°C (-40°F to 1472°F)
Infrared accuracy < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F);
> 0°C (32°F): ±1% or ±1.0°C (±2.0°F), whichever is greater
Display resolution 0.1°C / 0.1°F
Infrared spectral response 8 µm to 14 µm
Infrared response time < 500 ms
Thermocouple type-k input temperature range -270°C to 1372°C (-454°F to 2501°F)
Thermocouple type-k input accuracy < -40°C: ±(1°C + 0.2°/1°C)
≥ -40°C: ±1% or 1°C, whichever is greater < -40°F: ±(2°F + 0.2°/1°F)
≥ -40°F: ±1% or 2°F, whichever is greater
D:S (distance to measurement spot size) 50:1
Laser sighting Single-point laser
Minimum spot size 19 mm (0.75 in)
Emissivity adjustment By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage 99 points
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Display Dot matrix with function menus
Backlight Two levels, normal and extra bright for darker environments
Trigger lock Yes
Switchable celsius and fahrenheit Yes
Power 2 AAA/LR03 type-approved batteries (For a list of type-approved batteries, refer to Product Safety Instructions.)
Battery life 4 hours with laser and backlight on;
100 hours with laser and backlight off, at 100% duty cycle
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-40°F to 140°F)
Bead thermocouple type-k range -40°C to 260°C (-40°F to 500°F)
Bead thermocouple type-k accuracy ±1.1°C (2.0°F) from 0°C to 260°C (32 °F to 500°F),
typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)


Includes:

  • K-type thermocouple bead probe
  • Conductive IS hard carrying case
  • User’s manual

Related Products