{ "id":1076615348267, "title":"Fluke 572-2 High Temperature Infrared Thermometer","handle":"fluke-572-2-high-temperature-infrared-thermometer", "description":"\u003cp\u003e\u003cstrong\u003eFluke-572-2 High Temperature Infrared Thermometer measures temperatures up to 900°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Fluke 572-2 High-Temperature Infrared Thermometer is the ideal tool for high-temperature industrial environments all around the world. Whether you work in power utility, metal refining and smelting, glass, cement or petrochemical environments, the 572-2 offers the rugged performance accuracy you need to get the job done, backed by the most trusted name in test tools. The simple, three-button on-screen menu interface saves time and makes even complex measurements easy. With just a few pushes of a button you can adjust emissivity, start data logging, or turn on and off alarms. The 60:1 distance-to-spot ratio with dual laser sighting helps pinpoint the target fast, making it easier to measure small objects from a long distance.\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh temperature infrared thermometer that measures from -30°C to 900°C (-22°F to 1652°F)\u003c\/li\u003e\n\u003cli\u003eOffers an ultra-high 60:1 distance-to-spot ratio with dual laser sighting for fast, accurate targeting\u003c\/li\u003e\n\u003cli\u003eFeatures a user-selectable multi-language interface\u003c\/li\u003e\n\u003cli\u003eDisplays the temperature plus MAX, MIN, DIF, AVG temperature\u003c\/li\u003e\n\u003cli\u003eProvides adjustable emissivity and a predefined emissivity table.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eInfrared Measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfrared temperature range\u003c\/td\u003e\n\u003ctd\u003e-30°C to 900°C (-22°F to 1652°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\"\u003eIR accuracy (calibration geometry with ambient temperature 23°C ± 2°C)\u003c\/td\u003e\n\u003ctd\u003e≥ 0°C: ± 1°C or ± 1% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e≥ -10°C to \u0026lt; 0°C: ±2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e\u0026lt; -10°C: ±3°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e≥ 32°F: ± 2°F or ± 1% of the reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e≥ 14°F to \u0026lt; 32°F: ±4°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e\u0026lt; 14°F: ±6°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR repeatability\u003c\/td\u003e\n\u003ctd\u003e±0.5% of reading or ±0.5°C (±1°F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistance: Spot\u003c\/td\u003e\n\u003ctd\u003e60:1 (calculated at 90% energy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum spot size\u003c\/td\u003e\n\u003ctd\u003e19 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser sighting\u003c\/td\u003e\n\u003ctd\u003eOffset dual laser, output \u0026lt; 1 mW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral response\u003c\/td\u003e\n\u003ctd\u003e8 μm to 14 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time (95%)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 500 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmissivity\u003c\/td\u003e\n\u003ctd\u003eDigitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eContact Measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-type thermocouple input temperature range\u003c\/td\u003e\n\u003ctd\u003e-270°C to 1372°C (-454°F to 2501°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eK-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; -40°C: ±(1°C + 0.2° \/ 1°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e≥ -40°C: ±1% or 1°C, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e\u0026lt; -40°F: ±(2°F + 0.2° \/ 1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"nobold\"\u003e≥ -40°F: ±1% or 2°F, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-type thermocouple\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-type thermocouple repeatability\u003c\/td\u003e\n\u003ctd\u003e±0.5% of reading or ±0.5°C (±1°F), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eMeasurement Options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHi\/Low alarms\u003c\/td\u003e\n\u003ctd\u003eAudible and two-color visual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin\/Max\/Avg\/Dif\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitchable celsius and fahrenheit\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eTwo levels, normal and extra bright for darker environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe input\u003c\/td\u003e\n\u003ctd\u003eK-type thermocouple simultaneous display of probe and IR temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrigger lock\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData storage\u003c\/td\u003e\n\u003ctd\u003e99 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDot matrix 98 x 96 pixels with function menus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eK-Type Thermocouple Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement range (bead probe)\u003c\/td\u003e\n\u003ctd\u003e-40°C to 260°C (-40°F to 500°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1.1°C (±2.0°F) from 0°C to 260°C (32°F to 500°F). Typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length\u003c\/td\u003e\n\u003ctd\u003e1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"head\"\u003e\n\u003ctd colspan=\"2\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety and compliance\u003c\/td\u003e\n\u003ctd\u003eIEC 60825-1\u003cbr\u003eFDA Laser Class II\u003cbr\u003eIEC 61326-1\u003cbr\u003eCE Complaint\u003cbr\u003eCMC # 01120009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 60°C (-4°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 90% RH non-condensing up to 30°C (86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e2000 meters above mean sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.322 kg (0.7099 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e2 AA batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle (thermometer continuously on)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003eIncludes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eK-type thermocouple bead probe\u003c\/li\u003e\n\u003cli\u003eDurable hard case\u003c\/li\u003e\n\u003cli\u003eUSB 2.0 computer interface cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/Fluke_572-2_Spec_Sheet.PDF?1838\" target=\"_blank\" title=\"Fluke 572-2 Spec Sheet\" rel=\"noopener noreferrer\"\u003eFluke 572-2 Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2018-03-07T16:29:45", "created_at":"2018-03-07T16:32:53", "vendor":"Fluke", "type":"Infrared Thermometers", "tags":[], "price":168639, "price_min":168639, "price_max":168639, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[11044642226219], "variants":[{ "id":11044642226219, "product_id":1076615348267, "product_handle":"fluke-572-2-high-temperature-infrared-thermometer", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"FLU-572-2", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"Fluke 572-2 High Temperature Infrared Thermometer - Default Title", "options":["Default Title"], "price":168639, "weight":2268, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"095969667562"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/618V8n9UPjL._SL1500.jpg?v=1520465574","\/\/kingswayinstruments.com\/cdn\/shop\/products\/658847_GB_00_FB.EPS_1000.jpg?v=1520465575"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/618V8n9UPjL._SL1500.jpg?v=1520465574", "options":["Title"], "url":"\/products\/fluke-572-2-high-temperature-infrared-thermometer"}

Fluke 572-2 High Temperature Infrared Thermometer

Product Description

Fluke-572-2 High Temperature Infrared Thermometer measures temperatures up to 900°C

The Fluke 572-2 High-Temperature Infrared Thermometer is the ideal tool for high-temperature industrial environments all around the world. Whether you work in power utility, metal refining and smelting, glass, cement or petrochemical environments, the 572-2 offers the rugged performance accuracy you need to get the job done, backed by the most trusted name in test tools. The simple, three-button on-screen menu interface saves time and makes even complex measurements easy. With just a few pushes of a button you can adjust emissivity, start data logging, or turn on and off alarms. The 60:1 distance-to-spot ratio with dual laser sighting helps pinpoint the target fast, making it easier to measure small objects from a long distance.

Sku: FLU-572-2
Vendor: Fluke
On Back-Order
$1,686.39 CAD

  • High temperature infrared thermometer that measures from -30°C to 900°C (-22°F to 1652°F)
  • Offers an ultra-high 60:1 distance-to-spot ratio with dual laser sighting for fast, accurate targeting
  • Features a user-selectable multi-language interface
  • Displays the temperature plus MAX, MIN, DIF, AVG temperature
  • Provides adjustable emissivity and a predefined emissivity table.
Infrared Measurements
Infrared temperature range -30°C to 900°C (-22°F to 1652°F)
IR accuracy (calibration geometry with ambient temperature 23°C ± 2°C) ≥ 0°C: ± 1°C or ± 1% of the reading, whichever is greater
≥ -10°C to < 0°C: ±2°C
< -10°C: ±3°C
≥ 32°F: ± 2°F or ± 1% of the reading, whichever is greater
≥ 14°F to < 32°F: ±4°F
< 14°F: ±6°F
IR repeatability ±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Display resolution 0.1°C / 0.1°F
Distance: Spot 60:1 (calculated at 90% energy)
Minimum spot size 19 mm
Laser sighting Offset dual laser, output < 1 mW
Spectral response 8 μm to 14 μm
Response time (95%) < 500 ms
Emissivity Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials
Contact Measurements
K-type thermocouple input temperature range -270°C to 1372°C (-454°F to 2501°F)
K-type thermocouple input accuracy (with ambient temperature 23°C ± 2°C) < -40°C: ±(1°C + 0.2° / 1°C)
≥ -40°C: ±1% or 1°C, whichever is greater
< -40°F: ±(2°F + 0.2° / 1°F)
≥ -40°F: ±1% or 2°F, whichever is greater
K-type thermocouple 0.1°C / 0.1°F
K-type thermocouple repeatability ±0.5% of reading or ±0.5°C (±1°F), whichever is greater
Measurement Options
Hi/Low alarms Audible and two-color visual
Min/Max/Avg/Dif Yes
Switchable celsius and fahrenheit Yes
Backlight Two levels, normal and extra bright for darker environments
Probe input K-type thermocouple simultaneous display of probe and IR temperature
Trigger lock Yes
Data storage 99 points
Display Dot matrix 98 x 96 pixels with function menus
Communication USB 2.0
K-Type Thermocouple Specifications
Measurement range (bead probe) -40°C to 260°C (-40°F to 500°F)
Accuracy ±1.1°C (±2.0°F) from 0°C to 260°C (32°F to 500°F). Typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F)
Cable length 1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination
General Specifications
Safety and compliance IEC 60825-1
FDA Laser Class II
IEC 61326-1
CE Complaint
CMC # 01120009
Operating temperature 0°C to 50°C (32°F to 122°F)
Storage temperature -20°C to 60°C (-4°F to 140°F)
Relative humidity 10% to 90% RH non-condensing up to 30°C (86°F)
Operating altitude 2000 meters above mean sea level
Weight 0.322 kg (0.7099 lb)
Power 2 AA batteries
Battery life 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle (thermometer continuously on)


Includes:

  • K-type thermocouple bead probe
  • Durable hard case
  • USB 2.0 computer interface cable