{ "id":6173063971006, "title":"AEMC 203 True RMS Clamp Meter with Temperature, 600AAC\/900ADC","handle":"aemc-203-true-rms-clamp-meter-with-temperature-600aac-900adc", "description":"\u003cp\u003e\u003cspan\u003eThe True RMS Clamp-On Meter Model 203 is safety rated at 600V CAT IV. It measures AC+DC volts and amps, frequency, continuity, resistance, and temperature (with the supplied K thermocouple probe). The Model 203 can also perform diode checks. Its Adapter mode displays external sensor inputs. The Delta relative function compares new measurements to a reference value, and the MIN\/MAX function tracks high and low values. This compact and rugged meter can operate in demanding work environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eOverview\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUL94 VI flame retardant self-extinguishing\u003c\/li\u003e\n\u003cli\u003e6000-count blue electroluminescent backlit display\u003c\/li\u003e\n\u003cli\u003eMeasures up to 1000VAC (1400V peak), 1400VDC and AC+DC with resolution to 10mV\u003c\/li\u003e\n\u003cli\u003eMeasures up to 600AAC and 900ADC\u003c\/li\u003e\n\u003cli\u003eMeasures single- and three-phase power (real, reactive, and apparent) up to 600kW with resolution to 1W\u003c\/li\u003e\n\u003cli\u003eMeasures frequency to 20kHz with 0.1Hz resolution\u003c\/li\u003e\n\u003cli\u003eAuto selects AC or DC voltage measurement\u003c\/li\u003e\n\u003cli\u003eTrue InRush® current measurement with 1ms capture\u003c\/li\u003e\n\u003cli\u003eJaw opening to 1.33\" (34mm); IP54 Rated\u003c\/li\u003e\n\u003cli\u003eLeads are constructed with a flexible silicone material\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable width=\"100%\" class=\"specTable\" cellspacing=\"0\" cellpadding=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1000Vrms AC\/DC Autoranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e600Arms AC, 900ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResolution Max:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0.01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy V Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAccuracy A Typical:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1% ± 3cts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eInRush:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e6 to 600AAC, 6 to 900ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eContinuity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eSelectable from 0 to 599.9Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e60kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDiode Test:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e0 to 3.2VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eFrequency:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e20kHz in V, 3kHz in A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eTemperature K Thermocouple:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-76.0 to 2192°F (-60 to 1200°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eAdapter Function:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eMIN\/MAX:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1 x 9V, IEC LF22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eBattery Life:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e\u0026gt;130 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e8.7 x 3.1 x 1.65\" (222 x 78 x 42mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e12.0 oz. (340g) with battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eJaw Opening:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e1.34\" (34mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-4° to +131°F (-20 to +55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e-40° to +158°F (-40 to +70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e90% up to 131°F (55°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN61326-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"31%\"\u003e\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"68%\"\u003eEN\/IEC 61010-1: 1000V CAT III, 600V CAT IV\u003cbr\u003eEN\/IEC 61010-2-030:2010\u003cbr\u003eEN\/IEC 61010-032:2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e \u003c!-- split --\u003e\u003c\/p\u003e\n\u003ch2 class=\"hidden\"\u003eWhat's in the Box\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAEMC 203 True RMS Clamp Meter with Temperature, 600AAC\/900ADC\u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2 class=\"hidden\"\u003eResources\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2663\/3750\/files\/AEMC_200-400-600_Series_Clamps_-_High_Current_Spec.pdf?v=1610036163\" target=\"_blank\" title=\"AEMC 203 True RMS Clamp Meter Spec Sheet\" rel=\"noopener noreferrer\"\u003eAEMC 203 True RMS Clamp Meter Spec Sheet\u003c\/a\u003e\u003c\/p\u003e", "published_at":"2021-01-14T13:38:48", "created_at":"2021-01-14T13:38:46", "vendor":"AEMC Instruments", "type":"Clamp Meters", "tags":[], "price":32300, "price_min":32300, "price_max":32300, "price_varies":false, "compare_at_price":null, "compare_at_price_min":0, "compare_at_price_max":0, "compare_at_price_varies":true, "all_variant_ids":[37889858306238], "variants":[{ "id":37889858306238, "product_id":6173063971006, "product_handle":"aemc-203-true-rms-clamp-meter-with-temperature-600aac-900adc", "title":"Default Title", "option1":"Default Title", "option2":null, "option3":null, "sku":"AEMC-2139.12", "requires_shipping":true, "taxable":true, "featured_image":null,"image_id":null, "available":true, "name":"AEMC 203 True RMS Clamp Meter with Temperature, 600AAC\/900ADC - Default Title", "options":["Default Title"], "price":32300, "weight":4082, "compare_at_price":null, "inventory_quantity":0, "inventory_management":"shopify", "inventory_policy":"continue", "inventory_in_cart":0, "inventory_remaining":0, "incoming":false, "next_incoming_date":null, "taxable":true, "barcode":"685338110234"}], "available":true,"images":["\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC203Pic1.png?v=1610656729"],"featured_image":"\/\/kingswayinstruments.com\/cdn\/shop\/products\/AEMC203Pic1.png?v=1610656729", "options":["Title"], "url":"\/products\/aemc-203-true-rms-clamp-meter-with-temperature-600aac-900adc"}

AEMC 203 True RMS Clamp Meter with Temperature, 600AAC/900ADC

Product Description

The True RMS Clamp-On Meter Model 203 is safety rated at 600V CAT IV. It measures AC+DC volts and amps, frequency, continuity, resistance, and temperature (with the supplied K thermocouple probe). The Model 203 can also perform diode checks. Its Adapter mode displays external sensor inputs. The Delta relative function compares new measurements to a reference value, and the MIN/MAX function tracks high and low values. This compact and rugged meter can operate in demanding work environments.

Sku: AEMC-2139.12
On Back-Order
$323.00 CAD

  • UL94 VI flame retardant self-extinguishing
  • 6000-count blue electroluminescent backlit display
  • Measures up to 1000VAC (1400V peak), 1400VDC and AC+DC with resolution to 10mV
  • Measures up to 600AAC and 900ADC
  • Measures single- and three-phase power (real, reactive, and apparent) up to 600kW with resolution to 1W
  • Measures frequency to 20kHz with 0.1Hz resolution
  • Auto selects AC or DC voltage measurement
  • True InRush® current measurement with 1ms capture
  • Jaw opening to 1.33" (34mm); IP54 Rated
  • Leads are constructed with a flexible silicone material
Voltage Range: 1000Vrms AC/DC Autoranging
Resolution Max: 0.01V
Current Range: 600Arms AC, 900ADC
Resolution Max: 0.01A
Accuracy V Typical: 1% ± 3cts
Accuracy A Typical: 1% ± 3cts
InRush: 6 to 600AAC, 6 to 900ADC
Continuity: Selectable from 0 to 599.9Ω
Resistance: 60kΩ
Diode Test: 0 to 3.2VDC
Frequency: 20kHz in V, 3kHz in A
Temperature K Thermocouple: -76.0 to 2192°F (-60 to 1200°C)
Adapter Function: Yes
MIN/MAX: Yes
Power Source: 1 x 9V, IEC LF22
Battery Life: >130 hours
Dimensions: 8.7 x 3.1 x 1.65" (222 x 78 x 42mm)
Weight: 12.0 oz. (340g) with battery
Jaw Opening: 1.34" (34mm)
Operating Temperature: -4° to +131°F (-20 to +55°C)
Storage Temperature: -40° to +158°F (-40 to +70°C)
Operating Humidity: 90% up to 131°F (55°C)
Pollution Degree: 2
Ingress Protection: IP40
EMC: EN61326-1
Safety Compliance: EN/IEC 61010-1: 1000V CAT III, 600V CAT IV
EN/IEC 61010-2-030:2010
EN/IEC 61010-032:2002


AEMC 203 True RMS Clamp Meter with Temperature, 600AAC/900ADC